RPM HHV-448/458 High Voltage Board Replacement

Last Updated: 04/23/2025 1:42 AM

The following table lists all the components that make up the document.

Title Type Status Last Updated
Rapiscan VM-250 Vehicle Monitor
Device
Published
10/14/2024 9:50 AM
Rapiscan PM-700 Pedestrian Monitor
Device
Published
06/20/2024 11:38 AM
Rapiscan TM-850 Rail Monitor
Device
Published
09/18/2024 10:28 AM
Rapiscan CM-267 Conveyor Monitor
Device
Published
06/27/2024 1:02 PM
9508 - 1401 - Establish Initial Conditions; Remark:
Procedure Step
Published
10/03/2023 3:58 PM
1401 - Establish Initial Conditions
Instruction
Published
09/30/2022 3:14 PM
8490 - 7592 - Inform system operators; Remark:
Procedure Step
Published
09/16/2023 8:49 PM
7592 - Inform system operators
Instruction
Published
06/29/2023 3:20 PM
8221 - 7676 - Brief system operators on expected work, duration, anticipated alarms, and fa...; Remark:
Procedure Step
Published
09/01/2023 9:26 PM
7676 - Brief system operators on expected work, duration, anticipated alarms, and fa...
Instruction
Published
07/01/2023 11:39 PM
10312 - 7967 - Close lane and set up barriers or establish a safety watch; Remark:7595
Procedure Step
Published
11/17/2023 8:47 AM
7967 - Close lane and set up barriers or establish a safety watch
Instruction
Published
07/12/2023 12:41 AM
7595 - Use orange safety (traffic control) cones or equivalent per site-specific saf...
Remark
Published
06/29/2023 3:33 PM
7270 - 7235 - Power off RPM; Remark:7236
Procedure Step
Published
09/01/2023 7:57 PM
7235 - Power off RPM
Instruction
Published
04/24/2023 12:30 PM
7236 - Move LD-260 switch to OFF position. The PWR ON
Remark
Published
04/27/2023 4:25 PM
9646 - 9645 - Prepare for Faulty High Voltage Board Removal; Remark:
Procedure Step
Published
04/13/2025 6:15 PM
9645 - Prepare for Faulty High Voltage Board Removal
Instruction
Published
04/13/2025 6:02 PM
7852 - 7849 - Disconnect two cables on bottom of SCA-775 module; Remark:7851
Procedure Step
Published
07/08/2023 11:51 PM
7849 - Disconnect two cables on bottom of SCA-775 module
Instruction
Published
07/08/2023 11:46 PM
7851 - Connectors are disconnected by turning lock ring multiple times and then pull...
Remark
Published
07/08/2023 11:50 PM
7855 - 7853 - Disconnect all BNC and miniature high voltage (MHV) cables on top of SCA-775 ...; Remark:7854
Procedure Step
Published
07/08/2023 11:59 PM
7792 - Note : It is good engineering practice to ensure all cables and connectors are label...
Annotation
Published
07/07/2023 2:17 PM
7853 - Disconnect all BNC and miniature high voltage (MHV) cables on top of SCA-775 ...
Instruction
Published
07/08/2023 11:56 PM
7854 - BNC Connectors
Remark
Published
07/08/2023 11:58 PM
9709 - 9435 - Loosen screws in each corner (4) using a medium Philips screwdriver and open ...; Remark:9708
Procedure Step
Published
10/11/2023 10:48 PM
9435 - Loosen screws in each corner (4) using a medium Philips screwdriver and open ...
Instruction
Published
10/03/2023 2:00 PM
9708 - Normally the cover screws are “captured” and should not come out of the c...
Remark
Published
10/11/2023 10:47 PM
7861 - 7859 - Remove 4 mounting screws; Remark:7860
Procedure Step
Published
07/09/2023 12:12 AM
7858 - Note : Most replaceable bit type screwdrivers will be too large in diameter to fit i...
Annotation
Published
07/09/2023 12:06 AM
7859 - Remove 4 mounting screws
Instruction
Published
07/09/2023 12:07 AM
7860 - The screws to be removed are located in the bottom of the irregularly shaped ...
Remark
Published
07/09/2023 12:11 AM
7863 - 7862 - Remove SCA-775 module from back plate; Remark:
Procedure Step
Published
07/09/2023 12:15 AM
7862 - Remove SCA-775 module from back plate
Instruction
Published
07/09/2023 12:14 AM
7830 - 7799 - Disconnect 4 wiring harness assembly/connectors (J6, J8, J10, J11) from SCA-7...; Remark:7800
Procedure Step
Published
07/07/2023 11:04 PM
7798 - Caution : Never remove connectors by pulling on wires.
Annotation
Published
07/07/2023 5:41 PM
7799 - Disconnect 4 wiring harness assembly/connectors (J6, J8, J10, J11) from SCA-7...
Instruction
Published
07/07/2023 5:44 PM
7800 - J8 and J11 should be labeled; write J6 and J10 on the appropriate connector i...
Remark
Published
07/07/2023 9:27 PM
9658 - 9647 - Remove SCA-774 board from SCA-775 module; Remark:9648
Procedure Step
Published
10/11/2023 8:15 PM
9647 - Remove SCA-774 board from SCA-775 module
Instruction
Published
10/11/2023 7:55 PM
9648 - BNC connectors are attached to the SCA-774 board and easily slide down then o...
Remark
Published
10/11/2023 7:58 PM
9657 - 9650 - Uninstall Faulty High Voltage Board; Remark:
Procedure Step
Published
10/11/2023 8:14 PM
9649 - Note : If spare SCA-775 boxes or mounting plates are available it is advisable to re...
Annotation
Published
10/11/2023 8:00 PM
9650 - Uninstall Faulty High Voltage Board
Instruction
Published
10/11/2023 8:01 PM
9653 - 9651 - Remove four corners screws from high voltage plate to remove from box; Remark:9652
Procedure Step
Published
10/11/2023 8:07 PM
9651 - Remove four corners screws from high voltage plate to remove from box
Instruction
Published
10/11/2023 8:05 PM
9652 - High voltage plate
Remark
Published
10/11/2023 8:06 PM
9656 - 9654 - Disconnect wiring harness from faulty board(s); Remark:9655
Procedure Step
Published
10/11/2023 8:13 PM
9654 - Disconnect wiring harness from faulty board(s)
Instruction
Published
10/11/2023 8:09 PM
9655 - Faulty High Voltage Board
Remark
Published
10/11/2023 8:11 PM
9661 - 9659 - Remove faulty board; Remark:9660
Procedure Step
Published
10/11/2023 8:19 PM
9659 - Remove faulty board
Instruction
Published
10/11/2023 8:15 PM
9660 - Using a small Phillips screwdriver, remove screws at four corners.
Remark
Published
04/13/2025 6:02 PM
9707 - 9705 - Cut ground wire (black) and high-voltage wires (orange) as close to bad board...; Remark:9706
Procedure Step
Published
10/11/2023 10:39 PM
9705 - Cut ground wire (black) and high-voltage wires (orange) as close to bad board...
Instruction
Published
10/11/2023 10:37 PM
9706 -
Remark
Published
10/11/2023 10:38 PM
3397 - 3395 - Label faulty component; Remark:3396
Procedure Step
Published
07/21/2024 6:59 AM
3395 - Label faulty component
Instruction
Published
08/07/2021 11:07 AM
3396 - Use tag or tape. Include date of removal, description of failure symptoms, co...
Remark
Published
08/09/2021 11:35 AM
9696 - 9690 - Install New High Voltage Board (HHV-448 or HHV-458); Remark:
Procedure Step
Published
10/11/2023 9:31 PM
9690 - Install New High Voltage Board (HHV-448 or HHV-458)
Instruction
Published
10/11/2023 9:20 PM
9697 - 9691 - Strip approximately 3/8” of insulation off ground and high voltage wire fro...; Remark:
Procedure Step
Published
10/11/2023 9:32 PM
9691 - Strip approximately 3/8” of insulation off ground and high voltage wire fro...
Instruction
Published
10/11/2023 9:21 PM
9698 - 9692 - Cut “tinned” ends off of new high voltage board wires and strip approxima...; Remark:9693
Procedure Step
Published
10/11/2023 9:32 PM
9692 - Cut “tinned” ends off of new high voltage board wires and strip approxima...
Instruction
Published
10/11/2023 9:22 PM
9693 - Do not twist wires by hand
Remark
Published
10/11/2023 9:25 PM
9699 - 9694 - Slip sealed solder butt splice connector over one wire; Remark:9695
Procedure Step
Published
10/11/2023 9:33 PM
9694 - Slip sealed solder butt splice connector over one wire
Instruction
Published
10/11/2023 9:29 PM
9695 - Match wires and splice (intermingle) wire strands to form butt joint.
Remark
Published
10/11/2023 9:30 PM
9700 - 9689 - Place splice connector so solder ferrule is in center of splice; Remark:9688
Procedure Step
Published
10/11/2023 9:34 PM
9689 - Place splice connector so solder ferrule is in center of splice
Instruction
Published
10/11/2023 9:19 PM
9688 - Splice Connection
Remark
Published
10/11/2023 9:18 PM
9701 - 9686 - Heat with heat gun; Remark:9685
Procedure Step
Published
10/11/2023 9:35 PM
9687 - Caution : Do not overheat the wire and/or circuit boards when using heat gun. Do not po...
Annotation
Published
10/11/2023 9:16 PM
9686 - Heat with heat gun
Instruction
Published
10/11/2023 9:15 PM
9685 - Starting at center, gently distribute heat to ends until the inner tube is fu...
Remark
Published
10/11/2023 9:14 PM
9702 - 9683 - Wait for wires to cool; Remark:9684
Procedure Step
Published
10/11/2023 9:36 PM
9683 - Wait for wires to cool
Instruction
Published
10/11/2023 9:10 PM
9684 - Pull on wires to verify good connection.
Remark
Published
10/11/2023 9:11 PM
9703 - 9682 - Repeat steps 4-2 through 4-5 for each connection; Remark:
Procedure Step
Published
10/11/2023 9:36 PM
9682 - Repeat steps 4-2 through 4-5 for each connection
Instruction
Published
10/11/2023 9:10 PM
7279 - 7249 - Return equipment to normal operating condition; Remark:
Procedure Step
Published
04/27/2023 4:13 PM
7249 - Return equipment to normal operating condition
Instruction
Published
04/08/2025 3:22 PM
9681 - 9675 - Reinstall 4 screws to mount board back to 4 posts; Remark:9676
Procedure Step
Published
10/11/2023 9:07 PM
9675 - Reinstall 4 screws to mount board back to 4 posts
Instruction
Published
10/11/2023 9:01 PM
9676 - Mounting High Voltage Board
Remark
Published
10/11/2023 9:02 PM
9680 - 9673 - Reattach wiring harness; Remark:9674
Procedure Step
Published
10/11/2023 9:06 PM
7808 - Caution : Proper connection of wiring harnesses is critical.
Annotation
Published
07/07/2023 9:39 PM
9673 - Reattach wiring harness
Instruction
Published
10/11/2023 8:59 PM
9674 - Reattach wiring harness
Remark
Published
10/11/2023 9:00 PM
9679 - 9671 - Reinstall plate on SCA-775 module; Remark:9672
Procedure Step
Published
10/11/2023 9:05 PM
9671 - Reinstall plate on SCA-775 module
Instruction
Published
10/11/2023 8:56 PM
9672 - SCA-775 Plate
Remark
Published
10/11/2023 8:57 PM
9678 - 9670 - Ensure all connectors are securely mated to board; Remark:
Procedure Step
Published
10/11/2023 9:04 PM
9670 - Ensure all connectors are securely mated to board
Instruction
Published
10/11/2023 8:48 PM
9677 - 9668 - Secure SCA-774 board; Remark:9669
Procedure Step
Published
10/11/2023 9:03 PM
9668 - Secure SCA-774 board
Instruction
Published
10/11/2023 8:47 PM
9669 - Use screws previously removed.
Remark
Published
10/11/2023 8:48 PM
7835 - 7809 - Reconnect 4 wiring harness assembly/connectors (J6, J8, J10, J11) from SCA-77...; Remark:7810
Procedure Step
Published
10/11/2023 7:37 PM
7809 - Reconnect 4 wiring harness assembly/connectors (J6, J8, J10, J11) from SCA-77...
Instruction
Published
07/07/2023 9:42 PM
7810 - Ensure all pins are engaged. It is easy to install the connectors one pin off...
Remark
Published
07/07/2023 9:44 PM
9667 - 9665 - Reinstall 4 corner screws to mount SCA-775 module; Remark:9666
Procedure Step
Published
10/11/2023 8:30 PM
9665 - Reinstall 4 corner screws to mount SCA-775 module
Instruction
Published
10/11/2023 8:28 PM
9666 - Install all screws loosely at first to facilitate easy mounting, then careful...
Remark
Published
10/11/2023 8:30 PM
7836 - 7813 - Reconnect BNC connectors on top of SCA-775 module; Remark:
Procedure Step
Published
07/07/2023 11:42 PM
7811 - Caution : Proper connection of cables is critical.
Annotation
Published
07/07/2023 9:48 PM
7813 - Reconnect BNC connectors on top of SCA-775 module
Instruction
Published
07/07/2023 9:49 PM
7879 - 7878 - Reattach two connectors on bottom of SCA-775 module; Remark:7870
Procedure Step
Published
07/09/2023 1:16 AM
7878 - Reattach two connectors on bottom of SCA-775 module
Instruction
Published
07/09/2023 1:15 AM
7870 - The cable connectors are different sizes and keyed so they cannot be reinstal...
Remark
Published
07/09/2023 12:26 AM
8874 - 7250 - Power on RPM; Remark:7251
Procedure Step
Published
09/25/2023 2:12 PM
7250 - Power on RPM
Instruction
Published
05/01/2023 8:31 AM
7251 - Move LD-260 switch to ON position. The LED PWR ON
Remark
Published
05/10/2023 3:14 PM
7281 - 7252 - Verify RPM start-up; Remark:7253
Procedure Step
Published
04/20/2025 3:26 PM
7252 - Verify RPM start-up
Instruction
Published
04/27/2023 2:23 PM
7253 - RPM will perform a power on self-test (POST) and collect a background radiati...
Remark
Published
05/10/2023 3:14 PM
8506 - 7254 - Confirm network connection; Remark:7255
Procedure Step
Published
09/24/2023 3:34 PM
7254 - Confirm network connection
Instruction
Published
04/27/2023 2:22 PM
7255 - Contact operators to confirm communications have been reestablished between RPM ...
Remark
Published
05/10/2023 3:15 PM
9664 - 9662 - Navigate to SHOW COUNTS on SC-770 to verify gamma counts are...; Remark:9663
Procedure Step
Published
10/11/2023 8:27 PM
9662 - Navigate to SHOW COUNTS on SC-770 to verify gamma counts are...
Instruction
Published
10/11/2023 8:23 PM
9663 - Enter Program Mode by pressing "0" Press 01234#
Remark
Published
04/13/2025 6:01 PM
8580 - 8548 - Navigate to SHOW COUNTS for neutron channels; Remark:8549
Procedure Step
Published
09/17/2023 10:57 PM
8548 - Navigate to SHOW COUNTS for neutron channels
Instruction
Published
09/17/2023 9:22 PM
8549 - On SC-770, press 01234# Then, press 2:
Remark
Published
09/17/2023 9:26 PM
7840 - 7816 - Perform electronic alignment; Remark:7817
Procedure Step
Published
07/07/2023 11:12 PM
7816 - Perform electronic alignment
Instruction
Published
07/07/2023 9:55 PM
7817 - DET-RPM-RAP-CM01, RPM Electronic Alignment Procedure.
Remark
Published
04/13/2025 5:55 PM
8507 - 7256 - Close and lock all RPM doors; Remark:
Procedure Step
Published
09/24/2023 3:35 PM
7256 - Close and lock all RPM doors
Instruction
Published
04/27/2023 2:21 PM
7842 - 7820 - Inform system operators upon completion of maintenance action; Remark:
Procedure Step
Published
07/07/2023 11:15 PM
7820 - Inform system operators upon completion of maintenance action
Instruction
Published
07/07/2023 10:02 PM
322 - 321 - Document maintenance actions; Remark:
Procedure Step
Published
06/17/2021 9:49 AM
321 - Document maintenance actions
Instruction
Published
04/21/2025 11:19 AM
2869 - 2585 - Document maintenance performed; Remark:2866
Procedure Step
Published
06/18/2021 5:58 PM
2585 - Document maintenance performed
Instruction
Published
07/09/2021 12:15 PM
2866 - Record observations, times, and results for the maintenance report.
Remark
Published
04/21/2025 11:39 AM
4706 - 4705 - Submit report; Remark:4864
Procedure Step
Published
06/29/2022 9:50 AM
4705 - Submit report
Instruction
Published
06/29/2022 9:50 AM
4864 - As specified by management or contractual obligations.
Remark
Published
07/28/2022 1:36 PM
Corrective Maintenance Procedure
Document Type
Published
03/02/2020 3:32 PM
Upon failure of HHV-448 and/or HHV-458
Frequency
Published
10/11/2023 9:59 PM
Note
Annotation Type
Published
03/02/2020 3:25 PM
Caution
Annotation Type
Published
03/02/2020 3:24 PM
Technician 2
Skill Level
Published
04/09/2020 1:17 AM
Keys to access RPM
Replacement Parts
Published
04/27/2023 6:56 PM
Reflective safety vest if required
Replacement Parts
Published
06/20/2023 4:47 PM
Ladder; 2 meters, 6 feet tall; non-conducting if required
Replacement Parts
Published
07/02/2023 4:48 PM
Traffic control cones or equivalent if required
Replacement Parts
Published
06/20/2023 4:47 PM
safety glasses
Replacement Parts
Published
07/02/2023 4:48 PM
Medium Phillips (PH2) screwdriver
Tools
Published
04/24/2020 4:40 PM
Phillips screwdriver, small with 80 to 100 mm long shaft
Replacement Parts
Published
07/09/2023 1:06 AM
Small needle nose pliers
Tools
Published
11/21/2022 9:06 AM
Wire Crimpers
Tools
Published
11/03/2022 4:56 PM
Wire stripper
Tools
Published
09/25/2023 4:20 PM
Heat gun
Replacement Parts
Published
10/11/2023 10:10 PM
4 ELA5-16 sealed solder butt splices
Tools
Published
11/17/2023 8:38 AM
LD-260 Disconnect Switch Power Off
படம்
Published
04/24/2023 12:49 PM
SCA-775 Two Connectors
படம்
Published
07/08/2023 11:48 PM
SCA-775 BNC Connectors
படம்
Published
07/08/2023 11:57 PM
SCA-775 Screw Sockets
படம்
Published
07/09/2023 12:09 AM
High Voltage Plate on SCA-775 Box
படம்
Published
10/11/2023 8:04 PM
Faulty High Voltage Board
படம்
Published
10/11/2023 8:11 PM
Remove Faulty High Voltage Board
படம்
Published
10/11/2023 8:17 PM
Incorrect Way of Splicing Wires
படம்
Published
10/11/2023 9:24 PM
Match Wires When Soldering
படம்
Published
10/11/2023 9:28 PM
Slip Solder Connector
படம்
Published
10/11/2023 9:28 PM
Splice Connection
படம்
Published
10/11/2023 9:18 PM
Heat Solder Connection with Heat Gun
படம்
Published
10/11/2023 9:12 PM
Reinstall Wiring Harness for HVB
படம்
Published
10/11/2023 8:52 PM
Reinstall SCA-775 Plate
படம்
Published
10/11/2023 8:51 PM
LD-260 Disconnect Switch Power On
படம்
Published
05/04/2023 3:37 PM

RPM Tamper Switch Alignment, Replacement, and Repair

Last Updated: 04/23/2025 1:42 AM

The following table lists all the components that make up the document.

Title Type Status Last Updated
Rapiscan CM-267 Conveyor Monitor
Device
Published
06/27/2024 1:02 PM
Rapiscan PM-700 Pedestrian Monitor
Device
Published
06/20/2024 11:38 AM
Rapiscan TM-850 Rail Monitor
Device
Published
09/18/2024 10:28 AM
Rapiscan VM-250 Vehicle Monitor
Device
Published
10/14/2024 9:50 AM
9339 - 1401 - Establish Initial Conditions; Remark:
Procedure Step
Published
10/03/2023 9:55 AM
1401 - Establish Initial Conditions
Instruction
Published
09/30/2022 3:14 PM
7268 - 7231 - Close lane; Remark:7233
Procedure Step
Published
04/27/2023 7:01 PM
9053 - Warning : Traffic should temporarily be rerouted or halted during conduction of this pr...
Annotation
Published
09/27/2023 9:09 AM
7231 - Close lane
Instruction
Published
04/18/2023 1:00 PM
7233 - Use orange safety (traffic control) cones to setup barriers. Practice establi...
Remark
Published
04/24/2023 12:18 PM
7269 - 7232 - Open RPM door; Remark:7234
Procedure Step
Published
04/27/2023 7:02 PM
7232 - Open RPM door
Instruction
Published
04/18/2023 1:02 PM
7234 - Open all doors needed to access components.
Remark
Published
04/19/2025 7:48 PM
7270 - 7235 - Power off RPM; Remark:7236
Procedure Step
Published
09/01/2023 7:57 PM
7235 - Power off RPM
Instruction
Published
04/24/2023 12:30 PM
7236 - Move LD-260 switch to OFF position. The PWR ON
Remark
Published
04/27/2023 4:25 PM
9333 - 9237 - Verify Alignment of Tamper Switch and Magnet; Remark:
Procedure Step
Published
10/03/2023 9:58 AM
9291 - Note : Depending on the age and model of RPM, the tamper switch may be held in place by...
Annotation
Published
10/03/2023 10:38 AM
9292 - Note : The troubleshooting process should determine if the reed switch is bad, or if th...
Annotation
Published
10/03/2023 10:36 AM
9237 - Verify Alignment of Tamper Switch and Magnet
Instruction
Published
10/03/2023 12:01 PM
9329 - 9238 - Measure distance from inside edge of cabinet to edge of tamper switch; Remark:9296
Procedure Step
Published
10/03/2023 9:59 AM
9238 - Measure distance from inside edge of cabinet to edge of tamper switch
Instruction
Published
10/03/2023 11:59 AM
9296 - There is no predetermined position of a tamper switch. The switch may be located...
Remark
Published
10/03/2023 1:04 PM
9330 - 9239 - Measure distance from inside edge of door to edge of magnet; Remark:9297
Procedure Step
Published
10/03/2023 9:59 AM
9239 - Measure distance from inside edge of door to edge of magnet
Instruction
Published
10/03/2023 11:58 AM
9297 - The location of the magnet is determined by the location of the tamper switch.
Remark
Published
10/03/2023 1:03 PM
9331 - 9240 - Verify alignment of tamper switch and mag...; Remark:9298
Procedure Step
Published
10/03/2023 10:00 AM
9240 - Verify alignment of tamper switch and magnet
Instruction
Published
10/03/2023 11:58 AM
9298 - The alignment of the magnet and the tamper switch need to be within 6 mm (1/4 in...
Remark
Published
10/03/2023 1:03 PM
9332 - 9241 - Relocate tamper switch or magnet to corre...; Remark:9299
Procedure Step
Published
10/03/2023 10:00 AM
9293 - Note : Consider relocating the tamper switch, rather than the magnet, to minimize numbe...
Annotation
Published
10/03/2023 10:36 AM
9294 - Caution : Wear safety glasses as appropriate.
Annotation
Published
10/03/2023 10:35 AM
9241 - Relocate tamper switch or magnet to correct any misalignment, if necessary
Instruction
Published
10/03/2023 11:58 AM
9299 - Drill and tap new holes that align the tamper switch to the magnet using a porta...
Remark
Published
10/03/2023 1:02 PM
9328 - 9242 - Tamper Switch Replacement and Wiring Connection; Remark:
Procedure Step
Published
10/03/2023 10:01 AM
9242 - Tamper Switch Replacement and Wiring Connection
Instruction
Published
10/03/2023 11:57 AM
9322 - 9304 - Remove two screws of tamper switch using a medium Phillips screwdriver; Remark:9524
Procedure Step
Published
10/03/2023 10:01 AM
9304 - Remove two screws of tamper switch using a medium Phillips screwdriver
Instruction
Published
10/03/2023 11:56 AM
9524 -
Remark
Published
10/04/2023 11:21 AM
9323 - 9305 - Install new tamper switch with two screws...; Remark:9300
Procedure Step
Published
10/03/2023 10:01 AM
9305 - Install new tamper switch with two screws using a medium Phillips screwdriver
Instruction
Published
10/03/2023 11:56 AM
9300 - Reseal holes with RTV following tamper switch installation.
Remark
Published
10/03/2023 1:02 PM
9324 - 9306 - Determine if replacement terminal ends match existing terminal ends; Remark:9301
Procedure Step
Published
10/03/2023 10:02 AM
9306 - Determine if replacement terminal ends match existing terminal ends
Instruction
Published
10/03/2023 11:55 AM
9301 - If the replacement terminal ends do not match the existing terminal ends, it may...
Remark
Published
10/03/2023 1:01 PM
9325 - 9307 - Remove ¼ inch (6mm) of insulation from tamper switch wire end using wire stripp...; Remark:9523
Procedure Step
Published
10/03/2023 10:02 AM
9307 - Remove ¼ inch (6mm) of insulation from tamper switch wire end using wire stripp...
Instruction
Published
10/03/2023 11:55 AM
9523 -
Remark
Published
10/04/2023 11:23 AM
9326 - 9308 - Insert tamper switch wire into terminal end and crimp using crimping tool; Remark:9522
Procedure Step
Published
10/03/2023 10:02 AM
9308 - Insert tamper switch wire into terminal end and crimp using crimping tool
Instruction
Published
10/03/2023 11:54 AM
9522 -
Remark
Published
10/04/2023 11:24 AM
9327 - 9309 - Connect tamper switch to existing wiring using terminal end connectors; Remark:9521
Procedure Step
Published
10/03/2023 10:02 AM
9309 - Connect tamper switch to existing wiring using terminal end connectors
Instruction
Published
10/03/2023 10:42 AM
9521 -
Remark
Published
10/04/2023 11:25 AM
7279 - 7249 - Return equipment to normal operating condition; Remark:
Procedure Step
Published
04/27/2023 4:13 PM
7249 - Return equipment to normal operating condition
Instruction
Published
04/08/2025 3:22 PM
7280 - 7250 - Power on RPM; Remark:7251
Procedure Step
Published
04/27/2023 4:14 PM
7250 - Power on RPM
Instruction
Published
05/01/2023 8:31 AM
7251 - Move LD-260 switch to ON position. The LED PWR ON
Remark
Published
05/10/2023 3:14 PM
9318 - 9312 - Verify Control pillar tamper switch is operational; Remark:9302
Procedure Step
Published
10/03/2023 10:04 AM
9312 - Verify Control pillar tamper switch is operational
Instruction
Published
10/03/2023 10:41 AM
9302 - Open and close each door of the Control pillar, ensuring that the LED fault ligh...
Remark
Published
10/03/2023 1:01 PM
9319 - 9313 - Verify Auxiliary pillar tamper switch is ...; Remark:9303
Procedure Step
Published
10/03/2023 10:04 AM
9313 - Verify Auxiliary pillar tamper switch is operational
Instruction
Published
10/03/2023 10:40 AM
9303 - Open and close each door of the Auxiliary pillar, ensuring that the LED fault li...
Remark
Published
10/03/2023 1:01 PM
7281 - 7252 - Verify RPM start-up; Remark:7253
Procedure Step
Published
04/20/2025 3:26 PM
7252 - Verify RPM start-up
Instruction
Published
04/27/2023 2:23 PM
7253 - RPM will perform a power on self-test (POST) and collect a background radiati...
Remark
Published
05/10/2023 3:14 PM
7282 - 7254 - Confirm network connection; Remark:7255
Procedure Step
Published
04/27/2023 4:15 PM
7254 - Confirm network connection
Instruction
Published
04/27/2023 2:22 PM
7255 - Contact operators to confirm communications have been reestablished between RPM ...
Remark
Published
05/10/2023 3:15 PM
7283 - 7256 - Close and lock all RPM doors; Remark:
Procedure Step
Published
09/01/2023 11:45 PM
7256 - Close and lock all RPM doors
Instruction
Published
04/27/2023 2:21 PM
7842 - 7820 - Inform system operators upon completion of maintenance action; Remark:
Procedure Step
Published
07/07/2023 11:15 PM
7820 - Inform system operators upon completion of maintenance action
Instruction
Published
07/07/2023 10:02 PM
322 - 321 - Document maintenance actions; Remark:
Procedure Step
Published
06/17/2021 9:49 AM
321 - Document maintenance actions
Instruction
Published
04/21/2025 11:19 AM
2869 - 2585 - Document maintenance performed; Remark:2866
Procedure Step
Published
06/18/2021 5:58 PM
2585 - Document maintenance performed
Instruction
Published
07/09/2021 12:15 PM
2866 - Record observations, times, and results for the maintenance report.
Remark
Published
04/21/2025 11:39 AM
4706 - 4705 - Submit report; Remark:4864
Procedure Step
Published
06/29/2022 9:50 AM
4705 - Submit report
Instruction
Published
06/29/2022 9:50 AM
4864 - As specified by management or contractual obligations.
Remark
Published
07/28/2022 1:36 PM
Corrective Maintenance Procedure
Document Type
Published
03/02/2020 3:32 PM
1 hour
Duration
Published
04/01/2020 11:35 AM
Upon failure of tamper switch.
Frequency
Published
10/03/2023 10:08 AM
Upon intermittent tamper fault indicator.
Frequency
Published
10/03/2023 10:08 AM
Warning
Annotation Type
Published
03/02/2020 3:25 PM
Note
Annotation Type
Published
03/02/2020 3:25 PM
Caution
Annotation Type
Published
03/02/2020 3:24 PM
Technician 1
Skill Level
Published
05/14/2020 2:56 PM
Medium Phillips (PH2) screwdriver bit
Tools
Published
07/01/2022 11:18 AM
Measuring Tape
Tools
Published
10/03/2023 10:11 AM
Wire crimping tool
Tools
Published
09/25/2023 4:20 PM
Wire stripper
Tools
Published
09/25/2023 4:20 PM
Ladder; 2 meters, 6 feet tall; non-conducting if required
Replacement Parts
Published
07/02/2023 4:48 PM
Orange traffic cones
Replacement Parts
Published
04/27/2023 6:56 PM
Portable drill (if necessary)
Tools
Published
10/03/2023 10:11 AM
Mounting screw size (M3 x .5 metric or 4-40 UNC) and associated drill bit of matching size
Tools
Published
10/03/2023 10:12 AM
Tap- metric or standard (if necessary)
Tools
Published
10/03/2023 10:13 AM
Safety glasses if applicable
Replacement Parts
Published
06/29/2023 5:46 PM
LD-260 Disconnect Switch Power Off
படம்
Published
04/24/2023 12:49 PM
Measure distance from inside edge of cabinet to edge of tamper switch
படம்
Published
10/04/2023 11:10 AM
Measure distance from inside edge of door to edge of magnet
படம்
Published
10/04/2023 11:12 AM
Remove two screws of tamper switch using a medium Phillips screwdriver
படம்
Published
10/04/2023 11:14 AM
Determine if replacement terminal ends match existing terminal ends
படம்
Published
10/04/2023 11:13 AM
Remove ¼ inch (6mm) of insulation from tamper switch wire end using wire stripper
படம்
Published
10/04/2023 11:15 AM
Insert tamper switch wire into terminal end and crimp using crimping tool
படம்
Published
10/04/2023 11:15 AM
Connect tamper switch to existing wiring using terminal end connectors
படம்
Published
10/04/2023 11:16 AM
LD-260 Disconnect Switch Power On
படம்
Published
05/04/2023 3:37 PM

RPM SPY-2 to IXIO-DT1 Occupancy Sensor Conversion

Last Updated: 04/23/2025 1:42 AM

The following table lists all the components that make up the document.

Title Type Status Last Updated
Rapiscan PM-700 Pedestrian Monitor
Device
Published
06/20/2024 11:38 AM
1402 - 7927 - Establish Initial Conditions; Remark:
Procedure Step
Published
09/30/2022 1:47 PM
7927 - Establish Initial Conditions
Instruction
Published
07/12/2023 12:23 AM
8972 - 7231 - Close lane; Remark:7415
Procedure Step
Published
09/25/2023 10:51 PM
7231 - Close lane
Instruction
Published
04/18/2023 1:00 PM
7415 - Re-route pedestrian traffic.
Remark
Published
06/02/2023 1:08 PM
7269 - 7232 - Open RPM door; Remark:7234
Procedure Step
Published
04/27/2023 7:02 PM
7232 - Open RPM door
Instruction
Published
04/18/2023 1:02 PM
7234 - Open all doors needed to access components.
Remark
Published
04/19/2025 7:48 PM
7454 - 7290 - Disable tamper switches; Remark:7416
Procedure Step
Published
06/02/2023 5:25 PM
7290 - Disable tamper switches
Instruction
Published
05/01/2023 8:14 AM
7416 - Use a magnet to disable tamper switches for all open doors. Use adhesive tape...
Remark
Published
06/02/2023 1:18 PM
7270 - 7235 - Power off RPM; Remark:7236
Procedure Step
Published
09/01/2023 7:57 PM
7235 - Power off RPM
Instruction
Published
04/24/2023 12:30 PM
7236 - Move LD-260 switch to OFF position. The PWR ON
Remark
Published
04/27/2023 4:25 PM
7479 - 7417 - Prepare New Occupancy Sensor; Remark:
Procedure Step
Published
06/02/2023 6:13 PM
7417 - Prepare New Occupancy Sensor
Instruction
Published
06/02/2023 1:39 PM
7456 - 7418 - Remove cover from new occupancy sensor; Remark:7419
Procedure Step
Published
06/02/2023 5:27 PM
7418 - Remove cover from new occupancy sensor
Instruction
Published
06/02/2023 1:43 PM
7419 - Use a slotted screwdriver to pry the cover off from the side.
Remark
Published
04/13/2025 5:44 PM
7457 - 7420 - Verify narrow field radar antenna is installed; Remark:7421
Procedure Step
Published
04/13/2025 6:18 PM
7420 - Verify narrow field radar antenna is installed
Instruction
Published
04/13/2025 5:44 PM
7421 - The IXIO-DT1 should come with the narrow field antenna installed.
Remark
Published
06/02/2023 2:14 PM
8901 - If needed, the antenna can be changed. Remove cover. Install narrow field ant...
Remark
Published
09/25/2023 9:51 PM
8889 - 8888 - Prepare Mounting Holes; Remark:
Procedure Step
Published
09/25/2023 4:55 PM
8888 - Prepare Mounting Holes
Instruction
Published
09/25/2023 4:54 PM
8884 - 8883 - Mark mounting hole height; Remark:8882
Procedure Step
Published
09/25/2023 4:58 PM
8883 - Mark mounting hole height
Instruction
Published
09/25/2023 4:56 PM
8882 - Use erasable marker or pencil to draw a level horizontal line. Mounting hole ...
Remark
Published
09/25/2023 4:58 PM
8886 - 8879 - Mark centerline of pedestrian monitor door; Remark:8878
Procedure Step
Published
09/25/2023 5:01 PM
8879 - Mark centerline of pedestrian monitor door
Instruction
Published
09/25/2023 5:00 PM
8878 - Use erasable marker or pencil to draw a vertical line.
Remark
Published
09/25/2023 5:01 PM
8885 - 8881 - Attach mounting template; Remark:8880
Procedure Step
Published
09/25/2023 4:59 PM
8881 - Attach mounting template
Instruction
Published
09/25/2023 4:58 PM
8880 - Template provided with the IXIO-DT1 has a self-adhesive backing. Template may...
Remark
Published
09/25/2023 4:59 PM
8887 - 8877 - Mark location of 3.2-mm (1/8-inch) mounting holes; Remark:8876
Procedure Step
Published
09/25/2023 5:03 PM
8904 - Caution : Ensure placement of mounting holes will not interfere with internal wiring in...
Annotation
Published
09/25/2023 9:57 PM
8877 - Mark location of 3.2-mm (1/8-inch) mounting holes
Instruction
Published
09/25/2023 5:01 PM
8876 - If available, use a center punch and hammer to create a dimple at each mounti...
Remark
Published
09/25/2023 5:01 PM
8905 - 8903 - Mark location of 8-mm (5/16-inch) hole for wire passage; Remark:8902
Procedure Step
Published
09/25/2023 9:58 PM
8903 - Mark location of 8-mm (5/16-inch) hole for wire passage
Instruction
Published
09/25/2023 9:58 PM
8902 - If available, use a center punch and hammer to create a dimple at center of w...
Remark
Published
09/25/2023 9:58 PM
8946 - 8945 - Drill Installation Holes; Remark:
Procedure Step
Published
09/25/2023 10:01 PM
8945 - Drill Installation Holes
Instruction
Published
09/25/2023 10:01 PM
8939 - 8938 - Hold or block the door in an open position; Remark:
Procedure Step
Published
09/25/2023 10:01 PM
8938 - Hold or block the door in an open position
Instruction
Published
09/25/2023 10:01 PM
8940 - 8935 - Drill two (2) mounting holes; Remark:8934
Procedure Step
Published
09/25/2023 10:02 PM
8936 - Warning : Wear protective gloves and eyewear when drilling into cabinet door.
Annotation
Published
09/25/2023 10:05 PM
8937 - Caution : Do not damage interior of RPM when drilling holes.
Annotation
Published
09/25/2023 10:05 PM
8935 - Drill two (2) mounting holes
Instruction
Published
09/25/2023 10:02 PM
8934 - Use a 3.2-mm (1/8-inch) drill bit.
Remark
Published
09/25/2023 10:02 PM
8941 - 8933 - Drill wire passage hole; Remark:8932
Procedure Step
Published
09/25/2023 10:03 PM
8933 - Drill wire passage hole
Instruction
Published
09/25/2023 10:03 PM
8932 - Use an 8-mm (5/16-inch) drill bit.
Remark
Published
09/25/2023 10:03 PM
8942 - 8931 - Clean newly drilled holes; Remark:8930
Procedure Step
Published
09/25/2023 10:04 PM
8931 - Clean newly drilled holes
Instruction
Published
09/25/2023 10:04 PM
8930 - Use the deburring tool
Remark
Published
09/25/2023 10:04 PM
8943 - 8929 - Partially insert two (2) screws into mounting holes; Remark:8928
Procedure Step
Published
09/25/2023 10:06 PM
8929 - Partially insert two (2) screws into mounting holes
Instruction
Published
09/25/2023 10:06 PM
8928 - Mounting screws are included in the IXIO-DT-1 kit. Do not fully tighten screw...
Remark
Published
09/25/2023 10:06 PM
8944 - 8926 - Insert rubber grommet in wire passage hole; Remark:8925
Procedure Step
Published
09/25/2023 10:08 PM
8927 - Note : Protecting wires with a rubber grommet is critical to preventing damage to wi...
Annotation
Published
09/25/2023 10:08 PM
8926 - Insert rubber grommet in wire passage hole
Instruction
Published
09/25/2023 10:07 PM
8925 - rubber grommet
Remark
Published
09/25/2023 10:08 PM
8924 - 8923 - Install IXIO-DT1 Sensor; Remark:
Procedure Step
Published
09/25/2023 10:09 PM
8923 - Install IXIO-DT1 Sensor
Instruction
Published
09/25/2023 10:09 PM
8918 - 8917 - Feed wiring connector through grommet; Remark:8915
Procedure Step
Published
09/25/2023 10:13 PM
8917 - Feed wiring connector through grommet
Instruction
Published
09/25/2023 10:11 PM
8915 - The wiring assembly is included in the IXIO-DT1 kit. Feed loose end of wiring...
Remark
Published
09/25/2023 10:11 PM
8916 - Leave approximately 15 cm (6 in) of wire remaining outside of cabinet.
Remark
Published
09/25/2023 10:13 PM
8919 - 8914 - Mount new sensor; Remark:8912
Procedure Step
Published
09/25/2023 10:15 PM
8914 - Mount new sensor
Instruction
Published
09/25/2023 10:13 PM
8912 - First, slide left side onto mounting screw.
Remark
Published
09/25/2023 10:14 PM
8913 - Then, place right side over mounting screw and push down.
Remark
Published
09/25/2023 10:15 PM
8920 - 8911 - Tighten two (2) mounting screws; Remark:8910
Procedure Step
Published
09/25/2023 10:16 PM
8911 - Tighten two (2) mounting screws
Instruction
Published
09/25/2023 10:15 PM
8910 - Use medium Phillips (PH2) screwdriver. Take care not to overtighten.
Remark
Published
09/25/2023 10:16 PM
8921 - 8909 - Route wiring through clamp and connect; Remark:8908
Procedure Step
Published
09/25/2023 10:18 PM
8909 - Route wiring through clamp and connect
Instruction
Published
09/25/2023 10:16 PM
8908 - route wiring through clamp and connect
Remark
Published
09/25/2023 10:18 PM
8922 - 8907 - Adjust angle of the radar antenna; Remark:8906
Procedure Step
Published
09/25/2023 10:20 PM
8907 - Adjust angle of the radar antenna
Instruction
Published
09/25/2023 10:18 PM
8906 - The angle is adjusted by manually rotating the antenna up or down. The defaul...
Remark
Published
09/25/2023 10:20 PM
8970 - 8969 - Connect Wiring to RPM; Remark:
Procedure Step
Published
09/25/2023 10:23 PM
8969 - Connect Wiring to RPM
Instruction
Published
09/25/2023 10:22 PM
8963 - 8962 - Disconnect existing SPY-2 wiring; Remark:8961
Procedure Step
Published
09/25/2023 10:25 PM
7351 - Note : It is good practice to verify all cables and connectors are labeled prior to ...
Annotation
Published
05/03/2023 11:25 AM
8962 - Disconnect existing SPY-2 wiring
Instruction
Published
09/25/2023 10:24 PM
8961 - Do not remove existing occupancy sensor from door panel. Disconnect SPY-2 wir...
Remark
Published
09/25/2023 10:24 PM
8964 - 8960 - Route new cable to TB2; Remark:8959
Procedure Step
Published
09/25/2023 10:26 PM
8960 - Route new cable to TB2
Instruction
Published
09/25/2023 10:25 PM
8959 - New IXIO-DT1 cable should be routed along existing SPY-2 cable. Cable ties ma...
Remark
Published
09/25/2023 10:26 PM
8965 - 8958 - Connect red wire to TB2, Pin 16; Remark:8956
Procedure Step
Published
09/25/2023 10:30 PM
7263 - Caution : Correct placement of connectors and wiring is critical to proper operation.
Annotation
Published
04/24/2023 2:32 PM
8958 - Connect red wire to TB2, Pin 16
Instruction
Published
09/25/2023 10:27 PM
8956 - Red is power (+12 VDC) wire.
Remark
Published
09/25/2023 10:29 PM
8957 - For models with older terminal blocks, it may be necessary to use a fork conn...
Remark
Published
09/25/2023 10:30 PM
8966 - 8955 - Connect both black and white wires to TB2, Pin 15; Remark:8954
Procedure Step
Published
09/25/2023 10:32 PM
8955 - Connect both black and white wires to TB2, Pin 15
Instruction
Published
09/25/2023 10:31 PM
8954 - Black is the ground wire. White is the common wire
Remark
Published
09/25/2023 10:32 PM
8967 - 8953 - Connect green wire to TB2, Pin 6; Remark:8952
Procedure Step
Published
09/25/2023 10:34 PM
8953 - Connect green wire to TB2, Pin 6
Instruction
Published
09/25/2023 10:33 PM
8952 - Green is the occupancy signal to the SCA-775 module.
Remark
Published
09/25/2023 10:34 PM
8968 - 8951 - Apply sealant if needed; Remark:8950
Procedure Step
Published
09/25/2023 10:35 PM
8951 - Apply sealant if needed
Instruction
Published
09/25/2023 10:34 PM
8950 - Access wire penetration hole from back of the RPM door.
Remark
Published
09/25/2023 10:35 PM
7279 - 7249 - Return equipment to normal operating condition; Remark:
Procedure Step
Published
04/27/2023 4:13 PM
7249 - Return equipment to normal operating condition
Instruction
Published
04/08/2025 3:22 PM
8949 - 8948 - Hold door open; Remark:8947
Procedure Step
Published
09/25/2023 10:37 PM
8948 - Hold door open
Instruction
Published
09/25/2023 10:37 PM
8947 - Do not move door. Door must remain stationary to prevent occupancy.
Remark
Published
09/25/2023 10:37 PM
7280 - 7250 - Power on RPM; Remark:7251
Procedure Step
Published
04/27/2023 4:14 PM
7250 - Power on RPM
Instruction
Published
05/01/2023 8:31 AM
7251 - Move LD-260 switch to ON position. The LED PWR ON
Remark
Published
05/10/2023 3:14 PM
7468 - 7304 - Confirm RPM has restarted correctly; Remark:7487
Procedure Step
Published
06/02/2023 5:36 PM
7304 - Confirm RPM has restarted correctly
Instruction
Published
05/01/2023 8:31 AM
7487 - The SC-770 controller will display "OK" following Power On Self-Test (POST) a...
Remark
Published
06/02/2023 10:35 PM
7389 - 7254 - Confirm network connection; Remark:7255
Procedure Step
Published
05/04/2023 4:33 PM
7254 - Confirm network connection
Instruction
Published
04/27/2023 2:22 PM
7255 - Contact operators to confirm communications have been reestablished between RPM ...
Remark
Published
05/10/2023 3:15 PM
7470 - 7442 - Generate occupancy; Remark:7443
Procedure Step
Published
06/02/2023 5:37 PM
7442 - Generate occupancy
Instruction
Published
06/02/2023 4:19 PM
7443 - Create motion in front of occupancy sensor. While holding the door open and s...
Remark
Published
06/02/2023 4:21 PM
7471 - 7444 - Verify occupancy sensor functionality; Remark:7445
Procedure Step
Published
06/02/2023 5:38 PM
7444 - Verify occupancy sensor functionality
Instruction
Published
06/02/2023 4:32 PM
7445 - IXIO-DT1 green sensor light will illuminate.
Remark
Published
06/02/2023 4:35 PM
8973 - Left latch on the LCD screen will indicate a “closed” circuit.
Remark
Published
09/25/2023 11:05 PM
8974 - SC-770 status will read “OCCUPIED”.
Remark
Published
09/25/2023 11:06 PM
7472 - 7446 - Install sensor cover; Remark:7447
Procedure Step
Published
06/02/2023 5:38 PM
7446 - Install sensor cover
Instruction
Published
06/02/2023 4:37 PM
7447 - The cover should snap into place.
Remark
Published
06/02/2023 4:38 PM
7473 - 7448 - If needed, apply sealant; Remark:7449
Procedure Step
Published
06/02/2023 5:39 PM
7448 - If needed, apply sealant
Instruction
Published
06/02/2023 4:39 PM
7449 - If used outdoors, sealant should be applied to top and sides of cover. Do not...
Remark
Published
06/02/2023 4:41 PM
7474 - 7310 - Enable tamper switches; Remark:7451
Procedure Step
Published
06/02/2023 5:41 PM
7310 - Enable tamper switches
Instruction
Published
05/01/2023 8:36 AM
7451 - Remove magnets and/or adhesive tape from door tamper switches.
Remark
Published
04/13/2025 5:46 PM
7283 - 7256 - Close and lock all RPM doors; Remark:
Procedure Step
Published
09/01/2023 11:45 PM
7256 - Close and lock all RPM doors
Instruction
Published
04/27/2023 2:21 PM
7842 - 7820 - Inform system operators upon completion of maintenance action; Remark:
Procedure Step
Published
07/07/2023 11:15 PM
7820 - Inform system operators upon completion of maintenance action
Instruction
Published
07/07/2023 10:02 PM
322 - 321 - Document maintenance actions; Remark:
Procedure Step
Published
06/17/2021 9:49 AM
321 - Document maintenance actions
Instruction
Published
04/21/2025 11:19 AM
2869 - 2585 - Document maintenance performed; Remark:2866
Procedure Step
Published
06/18/2021 5:58 PM
2585 - Document maintenance performed
Instruction
Published
07/09/2021 12:15 PM
2866 - Record observations, times, and results for the maintenance report.
Remark
Published
04/21/2025 11:39 AM
4706 - 4705 - Submit report; Remark:4864
Procedure Step
Published
06/29/2022 9:50 AM
4705 - Submit report
Instruction
Published
06/29/2022 9:50 AM
4864 - As specified by management or contractual obligations.
Remark
Published
07/28/2022 1:36 PM
Corrective Maintenance Procedure
Document Type
Published
03/02/2020 3:32 PM
minutes
Duration
Published
05/26/2022 11:41 AM
Upon failure of the Visonic SPY-2 infrared curtain occupancy sensor
Frequency
Published
09/25/2023 3:49 PM
Caution
Annotation Type
Published
03/02/2020 3:24 PM
Warning
Annotation Type
Published
03/02/2020 3:25 PM
Note
Annotation Type
Published
03/02/2020 3:25 PM
Technician 2
Skill Level
Published
04/09/2020 1:17 AM
Keys to access RPM
Replacement Parts
Published
04/27/2023 6:56 PM
Magnets and adhesive tape to disable door tamper switches
Replacement Parts
Published
06/02/2023 10:08 PM
Medium Phillips (PH2) screwdriver
Tools
Published
04/24/2020 4:40 PM
Cordless drill
Tools
Published
09/25/2023 4:19 PM
3.2-mm (1/8-inch) drill bit (for metal)
Tools
Published
09/25/2023 4:19 PM
8-mm (5/16-inch) drill bit (for metal)
Tools
Published
09/25/2023 4:19 PM
Deburring tool
Tools
Published
09/25/2023 4:20 PM
safety glasses
Replacement Parts
Published
07/02/2023 4:48 PM
Gloves (heavy duty)
Tools
Published
09/25/2023 4:20 PM
Wire stripper
Tools
Published
09/25/2023 4:20 PM
Wire crimping tool
Tools
Published
09/25/2023 4:20 PM
Orange/yellow safety vest
Replacement Parts
Published
04/27/2023 6:56 PM
Safety shoes
Replacement Parts
Published
04/27/2023 6:56 PM
Protective headwear: glasses, hard hat
Replacement Parts
Published
05/10/2023 3:31 PM
Orange traffic cones
Replacement Parts
Published
04/27/2023 6:56 PM
Disable tamper switch
படம்
Published
09/07/2023 8:22 PM
Disable Tamper Switch
படம்
Published
06/02/2023 2:28 PM
LD-260 Disconnect Switch Power Off
படம்
Published
04/24/2023 12:49 PM
Remove Occupancy Sensor Cover
படம்
Published
06/02/2023 2:38 PM
The IXIO-DT1 should come with the narrow field antenna installed
படம்
Published
09/25/2023 8:35 PM
Verify narrow field radar antenna is installed
படம்
Published
09/25/2023 8:38 PM
Verify narrow field radar antenna is installed 2
படம்
Published
09/25/2023 8:39 PM
Mark mounting hole height
படம்
Published
09/25/2023 8:40 PM
Mark centerline of pedestrian monitor door
படம்
Published
09/25/2023 8:42 PM
Attach mounting template
படம்
Published
09/25/2023 8:44 PM
Mark location of 3.2-mm (1/8-inch) mounting holes
படம்
Published
09/25/2023 8:46 PM
Mark location of 8-mm (5/16-inch) hole for wire passage
படம்
Published
09/25/2023 8:47 PM
Insert rubber grommet in wire passage hole
படம்
Published
09/25/2023 8:48 PM
Feed wiring connector through grommet
படம்
Published
09/25/2023 8:50 PM
Feed wiring connector through grommet2
படம்
Published
09/25/2023 8:51 PM
Mount new sensor
படம்
Published
09/25/2023 8:52 PM
Mount new sensor2
படம்
Published
09/25/2023 8:53 PM
Tighten two (2) mounting screws
படம்
Published
09/25/2023 8:54 PM
Route wiring through clamp and connect
படம்
Published
09/25/2023 8:55 PM
Adjust angle of the radar antenna
படம்
Published
09/25/2023 8:56 PM
Adjust angle of the radar antenna2
படம்
Published
09/25/2023 8:58 PM
Disconnect existing SPY-2 wiring
படம்
Published
09/25/2023 8:59 PM
Route new cable to TB2
படம்
Published
09/25/2023 9:01 PM
Connect red wire to TB2, Pin 16
படம்
Published
09/25/2023 9:02 PM
Connect red wire to TB2, Pin 16 (2)
படம்
Published
09/25/2023 9:03 PM
fork connector
படம்
Published
09/25/2023 9:04 PM
Connect both black and white wires to TB2, Pin 15
படம்
Published
09/25/2023 9:06 PM
Connect green wire to TB2, Pin 6
படம்
Published
09/25/2023 9:34 PM
Apply sealant if needed
படம்
Published
09/25/2023 9:36 PM
LD-260 Disconnect Switch Power On
படம்
Published
05/04/2023 3:37 PM
IXIO-DT1 green sensor light will illuminate
படம்
Published
09/25/2023 9:37 PM
Verify occupancy sensor functionality
படம்
Published
09/25/2023 9:38 PM
Verify occupancy sensor functionality2
படம்
Published
09/25/2023 9:39 PM
Install Occupancy Sensor Cover
படம்
Published
06/02/2023 4:26 PM
Occupancy Sensor Sealant Application
படம்
Published
06/02/2023 4:30 PM
Remove Magnet from Tamper.PNG
படம்
Published
09/28/2023 9:37 AM
Remove Magnet on Tamper Switch
படம்
Published
06/02/2023 4:31 PM