Rapiscan PM-700 Pedestrian Monitor |
Device
|
Published
|
06/20/2024 11:38 AM
|
1402 - 7927 - Establish Initial Conditions; Remark: |
Procedure Step
|
Published
|
09/30/2022 1:47 PM
|
7927 - Establish Initial Conditions |
Instruction
|
Published
|
07/12/2023 12:23 AM
|
8972 - 7231 - Close lane; Remark:7415 |
Procedure Step
|
Published
|
09/25/2023 10:51 PM
|
7231 - Close lane |
Instruction
|
Published
|
04/18/2023 1:00 PM
|
7415 - Re-route pedestrian traffic. |
Remark
|
Published
|
06/02/2023 1:08 PM
|
7269 - 7232 - Open RPM door; Remark:7234 |
Procedure Step
|
Published
|
04/27/2023 7:02 PM
|
7232 - Open RPM door |
Instruction
|
Published
|
04/18/2023 1:02 PM
|
7234 - Open all doors needed to access components. |
Remark
|
Published
|
04/19/2025 7:48 PM
|
7454 - 7290 - Disable tamper switches; Remark:7416 |
Procedure Step
|
Published
|
06/02/2023 5:25 PM
|
7290 - Disable tamper switches |
Instruction
|
Published
|
05/01/2023 8:14 AM
|
7416 - Use a magnet to disable tamper switches for all open doors. Use adhesive tape... |
Remark
|
Published
|
06/02/2023 1:18 PM
|
7270 - 7235 - Power off RPM; Remark:7236 |
Procedure Step
|
Published
|
09/01/2023 7:57 PM
|
7235 - Power off RPM |
Instruction
|
Published
|
04/24/2023 12:30 PM
|
7236 - Move LD-260 switch to OFF position. The PWR ON |
Remark
|
Published
|
04/27/2023 4:25 PM
|
7479 - 7417 - Prepare New Occupancy Sensor; Remark: |
Procedure Step
|
Published
|
06/02/2023 6:13 PM
|
7417 - Prepare New Occupancy Sensor |
Instruction
|
Published
|
06/02/2023 1:39 PM
|
7456 - 7418 - Remove cover from new occupancy sensor; Remark:7419 |
Procedure Step
|
Published
|
06/02/2023 5:27 PM
|
7418 - Remove cover from new occupancy sensor |
Instruction
|
Published
|
06/02/2023 1:43 PM
|
7419 - Use a slotted screwdriver to pry the cover off from the side. |
Remark
|
Published
|
04/13/2025 5:44 PM
|
7457 - 7420 - Verify narrow field radar antenna is installed; Remark:7421 |
Procedure Step
|
Published
|
04/13/2025 6:18 PM
|
7420 - Verify narrow field radar antenna is installed |
Instruction
|
Published
|
04/13/2025 5:44 PM
|
7421 - The IXIO-DT1 should come with the narrow field antenna installed. |
Remark
|
Published
|
06/02/2023 2:14 PM
|
8901 - If needed, the antenna can be changed. Remove cover. Install narrow field ant... |
Remark
|
Published
|
09/25/2023 9:51 PM
|
8889 - 8888 - Prepare Mounting Holes; Remark: |
Procedure Step
|
Published
|
09/25/2023 4:55 PM
|
8888 - Prepare Mounting Holes |
Instruction
|
Published
|
09/25/2023 4:54 PM
|
8884 - 8883 - Mark mounting hole height; Remark:8882 |
Procedure Step
|
Published
|
09/25/2023 4:58 PM
|
8883 - Mark mounting hole height |
Instruction
|
Published
|
09/25/2023 4:56 PM
|
8882 - Use erasable marker or pencil to draw a level horizontal line. Mounting hole ... |
Remark
|
Published
|
09/25/2023 4:58 PM
|
8886 - 8879 - Mark centerline of pedestrian monitor door; Remark:8878 |
Procedure Step
|
Published
|
09/25/2023 5:01 PM
|
8879 - Mark centerline of pedestrian monitor door |
Instruction
|
Published
|
09/25/2023 5:00 PM
|
8878 - Use erasable marker or pencil to draw a vertical line. |
Remark
|
Published
|
09/25/2023 5:01 PM
|
8885 - 8881 - Attach mounting template; Remark:8880 |
Procedure Step
|
Published
|
09/25/2023 4:59 PM
|
8881 - Attach mounting template |
Instruction
|
Published
|
09/25/2023 4:58 PM
|
8880 - Template provided with the IXIO-DT1 has a self-adhesive backing. Template may... |
Remark
|
Published
|
09/25/2023 4:59 PM
|
8887 - 8877 - Mark location of 3.2-mm (1/8-inch) mounting holes; Remark:8876 |
Procedure Step
|
Published
|
09/25/2023 5:03 PM
|
8904 - Caution : Ensure placement of mounting holes will not interfere with internal wiring in... |
Annotation
|
Published
|
09/25/2023 9:57 PM
|
8877 - Mark location of 3.2-mm (1/8-inch) mounting holes |
Instruction
|
Published
|
09/25/2023 5:01 PM
|
8876 - If available, use a center punch and hammer to create a dimple at each mounti... |
Remark
|
Published
|
09/25/2023 5:01 PM
|
8905 - 8903 - Mark location of 8-mm (5/16-inch) hole for wire passage; Remark:8902 |
Procedure Step
|
Published
|
09/25/2023 9:58 PM
|
8903 - Mark location of 8-mm (5/16-inch) hole for wire passage |
Instruction
|
Published
|
09/25/2023 9:58 PM
|
8902 - If available, use a center punch and hammer to create a dimple at center of w... |
Remark
|
Published
|
09/25/2023 9:58 PM
|
8946 - 8945 - Drill Installation Holes; Remark: |
Procedure Step
|
Published
|
09/25/2023 10:01 PM
|
8945 - Drill Installation Holes |
Instruction
|
Published
|
09/25/2023 10:01 PM
|
8939 - 8938 - Hold or block the door in an open position; Remark: |
Procedure Step
|
Published
|
09/25/2023 10:01 PM
|
8938 - Hold or block the door in an open position |
Instruction
|
Published
|
09/25/2023 10:01 PM
|
8940 - 8935 - Drill two (2) mounting holes; Remark:8934 |
Procedure Step
|
Published
|
09/25/2023 10:02 PM
|
8936 - Warning : Wear protective gloves and eyewear when drilling into cabinet door. |
Annotation
|
Published
|
09/25/2023 10:05 PM
|
8937 - Caution : Do not damage interior of RPM when drilling holes. |
Annotation
|
Published
|
09/25/2023 10:05 PM
|
8935 - Drill two (2) mounting holes |
Instruction
|
Published
|
09/25/2023 10:02 PM
|
8934 - Use a 3.2-mm (1/8-inch) drill bit. |
Remark
|
Published
|
09/25/2023 10:02 PM
|
8941 - 8933 - Drill wire passage hole; Remark:8932 |
Procedure Step
|
Published
|
09/25/2023 10:03 PM
|
8933 - Drill wire passage hole |
Instruction
|
Published
|
09/25/2023 10:03 PM
|
8932 - Use an 8-mm (5/16-inch) drill bit. |
Remark
|
Published
|
09/25/2023 10:03 PM
|
8942 - 8931 - Clean newly drilled holes; Remark:8930 |
Procedure Step
|
Published
|
09/25/2023 10:04 PM
|
8931 - Clean newly drilled holes |
Instruction
|
Published
|
09/25/2023 10:04 PM
|
8930 - Use the deburring tool |
Remark
|
Published
|
09/25/2023 10:04 PM
|
8943 - 8929 - Partially insert two (2) screws into mounting holes; Remark:8928 |
Procedure Step
|
Published
|
09/25/2023 10:06 PM
|
8929 - Partially insert two (2) screws into mounting holes |
Instruction
|
Published
|
09/25/2023 10:06 PM
|
8928 - Mounting screws are included in the IXIO-DT-1 kit. Do not fully tighten screw... |
Remark
|
Published
|
09/25/2023 10:06 PM
|
8944 - 8926 - Insert rubber grommet in wire passage hole; Remark:8925 |
Procedure Step
|
Published
|
09/25/2023 10:08 PM
|
8927 - Note : Protecting wires with a rubber grommet is critical to preventing damage to wi... |
Annotation
|
Published
|
09/25/2023 10:08 PM
|
8926 - Insert rubber grommet in wire passage hole |
Instruction
|
Published
|
09/25/2023 10:07 PM
|
8925 - rubber grommet |
Remark
|
Published
|
09/25/2023 10:08 PM
|
8924 - 8923 - Install IXIO-DT1 Sensor; Remark: |
Procedure Step
|
Published
|
09/25/2023 10:09 PM
|
8923 - Install IXIO-DT1 Sensor |
Instruction
|
Published
|
09/25/2023 10:09 PM
|
8918 - 8917 - Feed wiring connector through grommet; Remark:8915 |
Procedure Step
|
Published
|
09/25/2023 10:13 PM
|
8917 - Feed wiring connector through grommet |
Instruction
|
Published
|
09/25/2023 10:11 PM
|
8915 - The wiring assembly is included in the IXIO-DT1 kit. Feed loose end of wiring... |
Remark
|
Published
|
09/25/2023 10:11 PM
|
8916 - Leave approximately 15 cm (6 in) of wire remaining outside of cabinet. |
Remark
|
Published
|
09/25/2023 10:13 PM
|
8919 - 8914 - Mount new sensor; Remark:8912 |
Procedure Step
|
Published
|
09/25/2023 10:15 PM
|
8914 - Mount new sensor |
Instruction
|
Published
|
09/25/2023 10:13 PM
|
8912 - First, slide left side onto mounting screw. |
Remark
|
Published
|
09/25/2023 10:14 PM
|
8913 - Then, place right side over mounting screw and push down. |
Remark
|
Published
|
09/25/2023 10:15 PM
|
8920 - 8911 - Tighten two (2) mounting screws; Remark:8910 |
Procedure Step
|
Published
|
09/25/2023 10:16 PM
|
8911 - Tighten two (2) mounting screws |
Instruction
|
Published
|
09/25/2023 10:15 PM
|
8910 - Use medium Phillips (PH2) screwdriver. Take care not to overtighten. |
Remark
|
Published
|
09/25/2023 10:16 PM
|
8921 - 8909 - Route wiring through clamp and connect; Remark:8908 |
Procedure Step
|
Published
|
09/25/2023 10:18 PM
|
8909 - Route wiring through clamp and connect |
Instruction
|
Published
|
09/25/2023 10:16 PM
|
8908 - route wiring through clamp and connect |
Remark
|
Published
|
09/25/2023 10:18 PM
|
8922 - 8907 - Adjust angle of the radar antenna; Remark:8906 |
Procedure Step
|
Published
|
09/25/2023 10:20 PM
|
8907 - Adjust angle of the radar antenna |
Instruction
|
Published
|
09/25/2023 10:18 PM
|
8906 - The angle is adjusted by manually rotating the antenna up or down. The defaul... |
Remark
|
Published
|
09/25/2023 10:20 PM
|
8970 - 8969 - Connect Wiring to RPM; Remark: |
Procedure Step
|
Published
|
09/25/2023 10:23 PM
|
8969 - Connect Wiring to RPM |
Instruction
|
Published
|
09/25/2023 10:22 PM
|
8963 - 8962 - Disconnect existing SPY-2 wiring; Remark:8961 |
Procedure Step
|
Published
|
09/25/2023 10:25 PM
|
7351 - Note : It is good practice to verify all cables and connectors are labeled prior to ... |
Annotation
|
Published
|
05/03/2023 11:25 AM
|
8962 - Disconnect existing SPY-2 wiring |
Instruction
|
Published
|
09/25/2023 10:24 PM
|
8961 - Do not remove existing occupancy sensor from door panel. Disconnect SPY-2 wir... |
Remark
|
Published
|
09/25/2023 10:24 PM
|
8964 - 8960 - Route new cable to TB2; Remark:8959 |
Procedure Step
|
Published
|
09/25/2023 10:26 PM
|
8960 - Route new cable to TB2 |
Instruction
|
Published
|
09/25/2023 10:25 PM
|
8959 - New IXIO-DT1 cable should be routed along existing SPY-2 cable. Cable ties ma... |
Remark
|
Published
|
09/25/2023 10:26 PM
|
8965 - 8958 - Connect red wire to TB2, Pin 16; Remark:8956 |
Procedure Step
|
Published
|
09/25/2023 10:30 PM
|
7263 - Caution : Correct placement of connectors and wiring is critical to proper operation. |
Annotation
|
Published
|
04/24/2023 2:32 PM
|
8958 - Connect red wire to TB2, Pin 16 |
Instruction
|
Published
|
09/25/2023 10:27 PM
|
8956 - Red is power (+12 VDC) wire. |
Remark
|
Published
|
09/25/2023 10:29 PM
|
8957 - For models with older terminal blocks, it may be necessary to use a fork conn... |
Remark
|
Published
|
09/25/2023 10:30 PM
|
8966 - 8955 - Connect both black and white wires to TB2, Pin 15; Remark:8954 |
Procedure Step
|
Published
|
09/25/2023 10:32 PM
|
8955 - Connect both black and white wires to TB2, Pin 15 |
Instruction
|
Published
|
09/25/2023 10:31 PM
|
8954 - Black is the ground wire. White is the common wire |
Remark
|
Published
|
09/25/2023 10:32 PM
|
8967 - 8953 - Connect green wire to TB2, Pin 6; Remark:8952 |
Procedure Step
|
Published
|
09/25/2023 10:34 PM
|
8953 - Connect green wire to TB2, Pin 6 |
Instruction
|
Published
|
09/25/2023 10:33 PM
|
8952 - Green is the occupancy signal to the SCA-775 module. |
Remark
|
Published
|
09/25/2023 10:34 PM
|
8968 - 8951 - Apply sealant if needed; Remark:8950 |
Procedure Step
|
Published
|
09/25/2023 10:35 PM
|
8951 - Apply sealant if needed |
Instruction
|
Published
|
09/25/2023 10:34 PM
|
8950 - Access wire penetration hole from back of the RPM door. |
Remark
|
Published
|
09/25/2023 10:35 PM
|
7279 - 7249 - Return equipment to normal operating condition; Remark: |
Procedure Step
|
Published
|
04/27/2023 4:13 PM
|
7249 - Return equipment to normal operating condition |
Instruction
|
Published
|
04/08/2025 3:22 PM
|
8949 - 8948 - Hold door open; Remark:8947 |
Procedure Step
|
Published
|
09/25/2023 10:37 PM
|
8948 - Hold door open |
Instruction
|
Published
|
09/25/2023 10:37 PM
|
8947 - Do not move door. Door must remain stationary to prevent occupancy. |
Remark
|
Published
|
09/25/2023 10:37 PM
|
7280 - 7250 - Power on RPM; Remark:7251 |
Procedure Step
|
Published
|
04/27/2023 4:14 PM
|
7250 - Power on RPM |
Instruction
|
Published
|
05/01/2023 8:31 AM
|
7251 - Move LD-260 switch to ON position. The LED PWR ON |
Remark
|
Published
|
05/10/2023 3:14 PM
|
7468 - 7304 - Confirm RPM has restarted correctly; Remark:7487 |
Procedure Step
|
Published
|
06/02/2023 5:36 PM
|
7304 - Confirm RPM has restarted correctly |
Instruction
|
Published
|
05/01/2023 8:31 AM
|
7487 - The SC-770 controller will display "OK" following Power On Self-Test (POST) a... |
Remark
|
Published
|
06/02/2023 10:35 PM
|
7389 - 7254 - Confirm network connection; Remark:7255 |
Procedure Step
|
Published
|
05/04/2023 4:33 PM
|
7254 - Confirm network connection |
Instruction
|
Published
|
04/27/2023 2:22 PM
|
7255 - Contact operators to confirm communications have been reestablished between RPM ... |
Remark
|
Published
|
05/10/2023 3:15 PM
|
7470 - 7442 - Generate occupancy; Remark:7443 |
Procedure Step
|
Published
|
06/02/2023 5:37 PM
|
7442 - Generate occupancy |
Instruction
|
Published
|
06/02/2023 4:19 PM
|
7443 - Create motion in front of occupancy sensor. While holding the door open and s... |
Remark
|
Published
|
06/02/2023 4:21 PM
|
7471 - 7444 - Verify occupancy sensor functionality; Remark:7445 |
Procedure Step
|
Published
|
06/02/2023 5:38 PM
|
7444 - Verify occupancy sensor functionality |
Instruction
|
Published
|
06/02/2023 4:32 PM
|
7445 - IXIO-DT1 green sensor light will illuminate. |
Remark
|
Published
|
06/02/2023 4:35 PM
|
8973 - Left latch on the LCD screen will indicate a “closed” circuit. |
Remark
|
Published
|
09/25/2023 11:05 PM
|
8974 - SC-770 status will read “OCCUPIED”. |
Remark
|
Published
|
09/25/2023 11:06 PM
|
7472 - 7446 - Install sensor cover; Remark:7447 |
Procedure Step
|
Published
|
06/02/2023 5:38 PM
|
7446 - Install sensor cover |
Instruction
|
Published
|
06/02/2023 4:37 PM
|
7447 - The cover should snap into place. |
Remark
|
Published
|
06/02/2023 4:38 PM
|
7473 - 7448 - If needed, apply sealant; Remark:7449 |
Procedure Step
|
Published
|
06/02/2023 5:39 PM
|
7448 - If needed, apply sealant |
Instruction
|
Published
|
06/02/2023 4:39 PM
|
7449 - If used outdoors, sealant should be applied to top and sides of cover. Do not... |
Remark
|
Published
|
06/02/2023 4:41 PM
|
7474 - 7310 - Enable tamper switches; Remark:7451 |
Procedure Step
|
Published
|
06/02/2023 5:41 PM
|
7310 - Enable tamper switches |
Instruction
|
Published
|
05/01/2023 8:36 AM
|
7451 - Remove magnets and/or adhesive tape from door tamper switches. |
Remark
|
Published
|
04/13/2025 5:46 PM
|
7283 - 7256 - Close and lock all RPM doors; Remark: |
Procedure Step
|
Published
|
09/01/2023 11:45 PM
|
7256 - Close and lock all RPM doors |
Instruction
|
Published
|
04/27/2023 2:21 PM
|
7842 - 7820 - Inform system operators upon completion of maintenance action; Remark: |
Procedure Step
|
Published
|
07/07/2023 11:15 PM
|
7820 - Inform system operators upon completion of maintenance action |
Instruction
|
Published
|
07/07/2023 10:02 PM
|
322 - 321 - Document maintenance actions; Remark: |
Procedure Step
|
Published
|
06/17/2021 9:49 AM
|
321 - Document maintenance actions |
Instruction
|
Published
|
04/21/2025 11:19 AM
|
2869 - 2585 - Document maintenance performed; Remark:2866 |
Procedure Step
|
Published
|
06/18/2021 5:58 PM
|
2585 - Document maintenance performed |
Instruction
|
Published
|
07/09/2021 12:15 PM
|
2866 - Record observations, times, and results for the maintenance report. |
Remark
|
Published
|
04/21/2025 11:39 AM
|
4706 - 4705 - Submit report; Remark:4864 |
Procedure Step
|
Published
|
06/29/2022 9:50 AM
|
4705 - Submit report |
Instruction
|
Published
|
06/29/2022 9:50 AM
|
4864 - As specified by management or contractual obligations. |
Remark
|
Published
|
07/28/2022 1:36 PM
|
Corrective Maintenance Procedure |
Document Type
|
Published
|
03/02/2020 3:32 PM
|
minutes |
Duration
|
Published
|
05/26/2022 11:41 AM
|
Upon failure of the Visonic SPY-2 infrared curtain occupancy sensor |
Frequency
|
Published
|
09/25/2023 3:49 PM
|
Caution |
Annotation Type
|
Published
|
03/02/2020 3:24 PM
|
Warning |
Annotation Type
|
Published
|
03/02/2020 3:25 PM
|
Note |
Annotation Type
|
Published
|
03/02/2020 3:25 PM
|
Technician 2 |
Skill Level
|
Published
|
04/09/2020 1:17 AM
|
Keys to access RPM |
Replacement Parts
|
Published
|
04/27/2023 6:56 PM
|
Magnets and adhesive tape to disable door tamper switches |
Replacement Parts
|
Published
|
06/02/2023 10:08 PM
|
Medium Phillips (PH2) screwdriver |
Tools
|
Published
|
04/24/2020 4:40 PM
|
Cordless drill |
Tools
|
Published
|
09/25/2023 4:19 PM
|
3.2-mm (1/8-inch) drill bit (for metal) |
Tools
|
Published
|
09/25/2023 4:19 PM
|
8-mm (5/16-inch) drill bit (for metal) |
Tools
|
Published
|
09/25/2023 4:19 PM
|
Deburring tool |
Tools
|
Published
|
09/25/2023 4:20 PM
|
safety glasses |
Replacement Parts
|
Published
|
07/02/2023 4:48 PM
|
Gloves (heavy duty) |
Tools
|
Published
|
09/25/2023 4:20 PM
|
Wire stripper |
Tools
|
Published
|
09/25/2023 4:20 PM
|
Wire crimping tool |
Tools
|
Published
|
09/25/2023 4:20 PM
|
Orange/yellow safety vest |
Replacement Parts
|
Published
|
04/27/2023 6:56 PM
|
Safety shoes |
Replacement Parts
|
Published
|
04/27/2023 6:56 PM
|
Protective headwear: glasses, hard hat |
Replacement Parts
|
Published
|
05/10/2023 3:31 PM
|
Orange traffic cones |
Replacement Parts
|
Published
|
04/27/2023 6:56 PM
|
Disable tamper switch |
படம்
|
Published
|
09/07/2023 8:22 PM
|
Disable Tamper Switch |
படம்
|
Published
|
06/02/2023 2:28 PM
|
LD-260 Disconnect Switch Power Off |
படம்
|
Published
|
04/24/2023 12:49 PM
|
Remove Occupancy Sensor Cover |
படம்
|
Published
|
06/02/2023 2:38 PM
|
The IXIO-DT1 should come with the narrow field antenna installed |
படம்
|
Published
|
09/25/2023 8:35 PM
|
Verify narrow field radar antenna is installed |
படம்
|
Published
|
09/25/2023 8:38 PM
|
Verify narrow field radar antenna is installed 2 |
படம்
|
Published
|
09/25/2023 8:39 PM
|
Mark mounting hole height |
படம்
|
Published
|
09/25/2023 8:40 PM
|
Mark centerline of pedestrian monitor door |
படம்
|
Published
|
09/25/2023 8:42 PM
|
Attach mounting template |
படம்
|
Published
|
09/25/2023 8:44 PM
|
Mark location of 3.2-mm (1/8-inch) mounting holes |
படம்
|
Published
|
09/25/2023 8:46 PM
|
Mark location of 8-mm (5/16-inch) hole for wire passage |
படம்
|
Published
|
09/25/2023 8:47 PM
|
Insert rubber grommet in wire passage hole |
படம்
|
Published
|
09/25/2023 8:48 PM
|
Feed wiring connector through grommet |
படம்
|
Published
|
09/25/2023 8:50 PM
|
Feed wiring connector through grommet2 |
படம்
|
Published
|
09/25/2023 8:51 PM
|
Mount new sensor |
படம்
|
Published
|
09/25/2023 8:52 PM
|
Mount new sensor2 |
படம்
|
Published
|
09/25/2023 8:53 PM
|
Tighten two (2) mounting screws |
படம்
|
Published
|
09/25/2023 8:54 PM
|
Route wiring through clamp and connect |
படம்
|
Published
|
09/25/2023 8:55 PM
|
Adjust angle of the radar antenna |
படம்
|
Published
|
09/25/2023 8:56 PM
|
Adjust angle of the radar antenna2 |
படம்
|
Published
|
09/25/2023 8:58 PM
|
Disconnect existing SPY-2 wiring |
படம்
|
Published
|
09/25/2023 8:59 PM
|
Route new cable to TB2 |
படம்
|
Published
|
09/25/2023 9:01 PM
|
Connect red wire to TB2, Pin 16 |
படம்
|
Published
|
09/25/2023 9:02 PM
|
Connect red wire to TB2, Pin 16 (2) |
படம்
|
Published
|
09/25/2023 9:03 PM
|
fork connector |
படம்
|
Published
|
09/25/2023 9:04 PM
|
Connect both black and white wires to TB2, Pin 15 |
படம்
|
Published
|
09/25/2023 9:06 PM
|
Connect green wire to TB2, Pin 6 |
படம்
|
Published
|
09/25/2023 9:34 PM
|
Apply sealant if needed |
படம்
|
Published
|
09/25/2023 9:36 PM
|
LD-260 Disconnect Switch Power On |
படம்
|
Published
|
05/04/2023 3:37 PM
|
IXIO-DT1 green sensor light will illuminate |
படம்
|
Published
|
09/25/2023 9:37 PM
|
Verify occupancy sensor functionality |
படம்
|
Published
|
09/25/2023 9:38 PM
|
Verify occupancy sensor functionality2 |
படம்
|
Published
|
09/25/2023 9:39 PM
|
Install Occupancy Sensor Cover |
படம்
|
Published
|
06/02/2023 4:26 PM
|
Occupancy Sensor Sealant Application |
படம்
|
Published
|
06/02/2023 4:30 PM
|
Remove Magnet from Tamper.PNG |
படம்
|
Published
|
09/28/2023 9:37 AM
|
Remove Magnet on Tamper Switch |
படம்
|
Published
|
06/02/2023 4:31 PM
|