RPM Cabinet Door Gasket Replacement

Last Updated: 04/23/2025 1:43 AM

The following table lists all the components that make up the document.

Title Type Status Last Updated
Rapiscan VM-250 Vehicle Monitor
Device
Published
10/14/2024 9:50 AM
Rapiscan CM-267 Conveyor Monitor
Device
Published
06/27/2024 1:02 PM
Rapiscan TM-850 Rail Monitor
Device
Published
09/18/2024 10:28 AM
Rapiscan PM-700 Pedestrian Monitor
Device
Published
06/20/2024 11:38 AM
1402 - 7927 - Establish Initial Conditions; Remark:
Procedure Step
Published
09/30/2022 1:47 PM
7927 - Establish Initial Conditions
Instruction
Published
07/12/2023 12:23 AM
10199 - 10198 - Assess if weather conditions are suitable to complete the full procedure ...; Remark:10197
Procedure Step
Published
10/24/2023 8:01 PM
10198 - Assess if weather conditions are suitable to complete the full procedure ...
Instruction
Published
10/24/2023 8:00 PM
10197 - If the temperature is below 10°C (50°F) or the door is damp due to rain or ...
Remark
Published
10/24/2023 8:01 PM
7268 - 7231 - Close lane; Remark:7233
Procedure Step
Published
04/27/2023 7:01 PM
9053 - Warning : Traffic should temporarily be rerouted or halted during conduction of this pr...
Annotation
Published
09/27/2023 9:09 AM
7231 - Close lane
Instruction
Published
04/18/2023 1:00 PM
7233 - Use orange safety (traffic control) cones to setup barriers. Practice establi...
Remark
Published
04/24/2023 12:18 PM
10196 - 10192 - Remove Old Gasket; Remark:
Procedure Step
Published
10/24/2023 8:05 PM
10192 - Remove Old Gasket
Instruction
Published
10/24/2023 8:02 PM
10188 - 10187 - Use putty knife to scrape gasket from door; Remark:10186
Procedure Step
Published
10/24/2023 8:06 PM
10193 - Note : Replacement gasket must be obtained prior to starting. The peel and stick gas...
Annotation
Published
10/24/2023 8:03 PM
10194 - Note : May be ordered from Rapiscan on a “per foot” basis, Part No. 6987G.
Annotation
Published
10/24/2023 8:03 PM
10195 - Note : For ordering, the total length required is shown in Total Gasket Length table...
Annotation
Published
10/24/2023 8:05 PM
10187 - Use putty knife to scrape gasket from door
Instruction
Published
10/24/2023 8:06 PM
10186 - Use care to not scrape the paint.
Remark
Published
10/24/2023 8:06 PM
10189 - 10185 - Discard loose material; Remark:
Procedure Step
Published
10/24/2023 8:07 PM
10185 - Discard loose material
Instruction
Published
10/24/2023 8:07 PM
10190 - 10184 - Apply acetone directly onto residue; Remark:10182
Procedure Step
Published
10/24/2023 8:08 PM
10184 - Apply acetone directly onto residue
Instruction
Published
10/24/2023 8:08 PM
10182 - Either spray or squirt Acetone onto residue and allow soaking for a few minut...
Remark
Published
10/24/2023 8:08 PM
10183 - Use care to not scrape the paint. A razor blade and acetone may be necessary ...
Remark
Published
10/24/2023 8:08 PM
10191 - 10181 - Remove any remaining adhesive; Remark:10180
Procedure Step
Published
10/24/2023 8:09 PM
10181 - Remove any remaining adhesive
Instruction
Published
10/24/2023 8:09 PM
10180 - Use additional acetone and paper towels as needed.
Remark
Published
10/24/2023 8:09 PM
10179 - 10178 - Prep Area for Install of New Gasket; Remark:
Procedure Step
Published
10/24/2023 8:11 PM
10178 - Prep Area for Install of New Gasket
Instruction
Published
10/24/2023 8:11 PM
10175 - 10174 - Clean affected surface with rubbing alcohol and paper towels; Remark:10173
Procedure Step
Published
10/24/2023 8:12 PM
10174 - Clean affected surface with rubbing alcohol and paper towels
Instruction
Published
10/24/2023 8:12 PM
10173 - Remaining adhesive will become slightly sticky.
Remark
Published
10/24/2023 8:12 PM
10176 - 10172 - Wait until conditions are optimal; Remark:10169
Procedure Step
Published
10/24/2023 8:15 PM
10172 - Wait until conditions are optimal
Instruction
Published
10/24/2023 8:13 PM
10169 - To help promote a strong bond, the surface area needs to be free of the origi...
Remark
Published
10/24/2023 8:13 PM
10170 - If the temperature is below 10°C (50°F) or the door is damp due to rain or ...
Remark
Published
10/24/2023 8:14 PM
10171 - If removing the doors, be sure to protect the electronics and detectors from ...
Remark
Published
10/24/2023 8:14 PM
10177 - 10167 - Measure and cut appropriate lengths of gasket material required; Remark:10164
Procedure Step
Published
10/24/2023 8:18 PM
10168 - Caution : Incomplete seals may cause environmental damage to the cabinet contents. Gask...
Annotation
Published
10/24/2023 8:18 PM
10167 - Measure and cut appropriate lengths of gasket material required
Instruction
Published
10/24/2023 8:15 PM
10164 - Use scissors and measuring tape.
Remark
Published
10/24/2023 8:16 PM
10165 - Use Gasket Segment Lengths table for appropriate gasket lengths.
Remark
Published
10/24/2023 8:16 PM
10166 - Suggested technique is to add 3-5 cm to the listed length for the initial cut...
Remark
Published
10/24/2023 8:17 PM
10202 - Gasket Segment Lengths
Remark
Published
10/24/2023 8:31 PM
10203 - 10200 - Mark gasket location on door using attached drawing; Remark:
Procedure Step
Published
10/24/2023 8:34 PM
10201 - Standard : The gasket spacing to the door edge on the top, lock side, and bottom is appr...
Annotation
Published
10/24/2023 8:34 PM
10200 - Mark gasket location on door using attached drawing
Instruction
Published
10/24/2023 8:33 PM
10230 - 10229 - Preheat gasket and/or contact area; Remark:10228
Procedure Step
Published
10/24/2023 9:28 PM
10229 - Preheat gasket and/or contact area
Instruction
Published
10/24/2023 9:28 PM
10228 - Use a hair dryer or similar device until gasket is warm to your touch. This w...
Remark
Published
10/24/2023 9:28 PM
10227 - 10226 - Install New Gasket; Remark:10225
Procedure Step
Published
10/24/2023 9:34 PM
10226 - Install New Gasket
Instruction
Published
10/24/2023 9:29 PM
10225 - gasket application order
Remark
Published
10/24/2023 9:34 PM
10221 - 10220 - Peel protective paper backing from top gasket and attach adhesive side of gas...; Remark:10219
Procedure Step
Published
10/24/2023 9:36 PM
10314 - Caution : Do not stretch or pull the gaskets when placing them on the door as this can ...
Annotation
Published
11/17/2023 8:56 AM
10315 - Note : Attaching the gaskets to the door in the correct sequence is important to kee...
Annotation
Published
11/17/2023 8:57 AM
10220 - Peel protective paper backing from top gasket and attach adhesive side of gas...
Instruction
Published
10/24/2023 9:36 PM
10219 - (This is the first application.) Use care when removing/peeling backing paper...
Remark
Published
10/24/2023 9:36 PM
10222 - 10218 - Peel protective paper backing from side gasket and attach adhesive side of ga...; Remark:10217
Procedure Step
Published
10/24/2023 9:37 PM
10218 - Peel protective paper backing from side gasket and attach adhesive side of ga...
Instruction
Published
10/24/2023 9:36 PM
10217 - (This is the second application.)
Remark
Published
10/24/2023 9:37 PM
10223 - 10216 - Peel protective paper backing from side gasket and attach adhesive side of ga...; Remark:10215
Procedure Step
Published
10/24/2023 9:38 PM
10216 - Peel protective paper backing from side gasket and attach adhesive side of ga...
Instruction
Published
10/24/2023 9:38 PM
10215 - (This is the third application.)
Remark
Published
10/24/2023 9:38 PM
10224 - 10214 - Peel protective paper backing from bottom gasket and attach adhesive side of ...; Remark:10213
Procedure Step
Published
10/24/2023 9:40 PM
10214 - Peel protective paper backing from bottom gasket and attach adhesive side of ...
Instruction
Published
10/24/2023 9:39 PM
10213 - (This is the fourth application.)
Remark
Published
10/24/2023 9:39 PM
7279 - 7249 - Return equipment to normal operating condition; Remark:
Procedure Step
Published
04/27/2023 4:13 PM
7249 - Return equipment to normal operating condition
Instruction
Published
04/08/2025 3:22 PM
10210 - 10209 - Close cabinet door; Remark:
Procedure Step
Published
10/24/2023 9:42 PM
10209 - Close cabinet door
Instruction
Published
10/24/2023 9:42 PM
10211 - 10207 - Keep door closed for at least 24 hours; Remark:10206
Procedure Step
Published
10/24/2023 9:44 PM
10208 - Note : Cure times vary depending on temperature and humidity.
Annotation
Published
10/24/2023 9:44 PM
10207 - Keep door closed for at least 24 hours
Instruction
Published
10/24/2023 9:43 PM
10206 - The constant pressure of the door will help create a strong bond during the 2...
Remark
Published
10/24/2023 9:44 PM
10212 - 10205 - Check gasket adhesion at end of 24 hours; Remark:10204
Procedure Step
Published
10/24/2023 9:46 PM
10205 - Check gasket adhesion at end of 24 hours
Instruction
Published
10/24/2023 9:45 PM
10204 - Check temperature or cleanliness of surface if gasket does not adhere properl...
Remark
Published
10/24/2023 9:46 PM
8260 - 8250 - Reopen Lane; Remark:8249
Procedure Step
Published
09/07/2023 3:09 PM
8250 - Reopen Lane
Instruction
Published
09/07/2023 3:09 PM
8249 - Remove orange safety (traffic control) cones
Remark
Published
09/07/2023 3:09 PM
7842 - 7820 - Inform system operators upon completion of maintenance action; Remark:
Procedure Step
Published
07/07/2023 11:15 PM
7820 - Inform system operators upon completion of maintenance action
Instruction
Published
07/07/2023 10:02 PM
322 - 321 - Document maintenance actions; Remark:
Procedure Step
Published
06/17/2021 9:49 AM
321 - Document maintenance actions
Instruction
Published
04/21/2025 11:19 AM
2869 - 2585 - Document maintenance performed; Remark:2866
Procedure Step
Published
06/18/2021 5:58 PM
2585 - Document maintenance performed
Instruction
Published
07/09/2021 12:15 PM
2866 - Record observations, times, and results for the maintenance report.
Remark
Published
04/21/2025 11:39 AM
4706 - 4705 - Submit report; Remark:4864
Procedure Step
Published
06/29/2022 9:50 AM
4705 - Submit report
Instruction
Published
06/29/2022 9:50 AM
4864 - As specified by management or contractual obligations.
Remark
Published
07/28/2022 1:36 PM
Corrective Maintenance Procedure
Document Type
Published
03/02/2020 3:32 PM
hours
Duration
Published
05/26/2022 11:45 AM
Upon damage or no longer sealing properly
Frequency
Published
10/23/2023 3:03 PM
Warning
Annotation Type
Published
03/02/2020 3:25 PM
Note
Annotation Type
Published
03/02/2020 3:25 PM
Caution
Annotation Type
Published
03/02/2020 3:24 PM
Standard
Annotation Type
Published
03/02/2020 3:25 PM
Technician 1
Skill Level
Published
05/14/2020 2:56 PM
Narrow putty knife or paint scraper
Tools
Published
10/23/2023 4:18 PM
Razor blade scraper
Tools
Published
10/23/2023 4:18 PM
Measuring Tape
Tools
Published
10/03/2023 10:11 AM
Scissors
Tools
Published
05/19/2020 1:54 PM
Permanent marker
Tools
Published
10/23/2023 10:07 AM
Keys to access RPM
Replacement Parts
Published
04/27/2023 6:56 PM
Ladder: 2 meters, 6 feet tall; non-conducting
Replacement Parts
Published
09/01/2023 9:34 PM
Orange traffic cones
Replacement Parts
Published
04/27/2023 6:56 PM
safety glasses
Replacement Parts
Published
07/02/2023 4:48 PM
Gloves
Replacement Parts
Published
05/10/2023 3:28 PM
Gasket segment lengths_0.png
படம்
Published
10/24/2023 9:23 PM
gasket application order
படம்
Published
10/24/2023 9:33 PM

RPM Tamper Switch Alignment, Replacement, and Repair

Last Updated: 04/23/2025 1:42 AM

The following table lists all the components that make up the document.

Title Type Status Last Updated
Rapiscan CM-267 Conveyor Monitor
Device
Published
06/27/2024 1:02 PM
Rapiscan PM-700 Pedestrian Monitor
Device
Published
06/20/2024 11:38 AM
Rapiscan TM-850 Rail Monitor
Device
Published
09/18/2024 10:28 AM
Rapiscan VM-250 Vehicle Monitor
Device
Published
10/14/2024 9:50 AM
9339 - 1401 - Establish Initial Conditions; Remark:
Procedure Step
Published
10/03/2023 9:55 AM
1401 - Establish Initial Conditions
Instruction
Published
09/30/2022 3:14 PM
7268 - 7231 - Close lane; Remark:7233
Procedure Step
Published
04/27/2023 7:01 PM
9053 - Warning : Traffic should temporarily be rerouted or halted during conduction of this pr...
Annotation
Published
09/27/2023 9:09 AM
7231 - Close lane
Instruction
Published
04/18/2023 1:00 PM
7233 - Use orange safety (traffic control) cones to setup barriers. Practice establi...
Remark
Published
04/24/2023 12:18 PM
7269 - 7232 - Open RPM door; Remark:7234
Procedure Step
Published
04/27/2023 7:02 PM
7232 - Open RPM door
Instruction
Published
04/18/2023 1:02 PM
7234 - Open all doors needed to access components.
Remark
Published
04/19/2025 7:48 PM
7270 - 7235 - Power off RPM; Remark:7236
Procedure Step
Published
09/01/2023 7:57 PM
7235 - Power off RPM
Instruction
Published
04/24/2023 12:30 PM
7236 - Move LD-260 switch to OFF position. The PWR ON
Remark
Published
04/27/2023 4:25 PM
9333 - 9237 - Verify Alignment of Tamper Switch and Magnet; Remark:
Procedure Step
Published
10/03/2023 9:58 AM
9291 - Note : Depending on the age and model of RPM, the tamper switch may be held in place by...
Annotation
Published
10/03/2023 10:38 AM
9292 - Note : The troubleshooting process should determine if the reed switch is bad, or if th...
Annotation
Published
10/03/2023 10:36 AM
9237 - Verify Alignment of Tamper Switch and Magnet
Instruction
Published
10/03/2023 12:01 PM
9329 - 9238 - Measure distance from inside edge of cabinet to edge of tamper switch; Remark:9296
Procedure Step
Published
10/03/2023 9:59 AM
9238 - Measure distance from inside edge of cabinet to edge of tamper switch
Instruction
Published
10/03/2023 11:59 AM
9296 - There is no predetermined position of a tamper switch. The switch may be located...
Remark
Published
10/03/2023 1:04 PM
9330 - 9239 - Measure distance from inside edge of door to edge of magnet; Remark:9297
Procedure Step
Published
10/03/2023 9:59 AM
9239 - Measure distance from inside edge of door to edge of magnet
Instruction
Published
10/03/2023 11:58 AM
9297 - The location of the magnet is determined by the location of the tamper switch.
Remark
Published
10/03/2023 1:03 PM
9331 - 9240 - Verify alignment of tamper switch and mag...; Remark:9298
Procedure Step
Published
10/03/2023 10:00 AM
9240 - Verify alignment of tamper switch and magnet
Instruction
Published
10/03/2023 11:58 AM
9298 - The alignment of the magnet and the tamper switch need to be within 6 mm (1/4 in...
Remark
Published
10/03/2023 1:03 PM
9332 - 9241 - Relocate tamper switch or magnet to corre...; Remark:9299
Procedure Step
Published
10/03/2023 10:00 AM
9293 - Note : Consider relocating the tamper switch, rather than the magnet, to minimize numbe...
Annotation
Published
10/03/2023 10:36 AM
9294 - Caution : Wear safety glasses as appropriate.
Annotation
Published
10/03/2023 10:35 AM
9241 - Relocate tamper switch or magnet to correct any misalignment, if necessary
Instruction
Published
10/03/2023 11:58 AM
9299 - Drill and tap new holes that align the tamper switch to the magnet using a porta...
Remark
Published
10/03/2023 1:02 PM
9328 - 9242 - Tamper Switch Replacement and Wiring Connection; Remark:
Procedure Step
Published
10/03/2023 10:01 AM
9242 - Tamper Switch Replacement and Wiring Connection
Instruction
Published
10/03/2023 11:57 AM
9322 - 9304 - Remove two screws of tamper switch using a medium Phillips screwdriver; Remark:9524
Procedure Step
Published
10/03/2023 10:01 AM
9304 - Remove two screws of tamper switch using a medium Phillips screwdriver
Instruction
Published
10/03/2023 11:56 AM
9524 -
Remark
Published
10/04/2023 11:21 AM
9323 - 9305 - Install new tamper switch with two screws...; Remark:9300
Procedure Step
Published
10/03/2023 10:01 AM
9305 - Install new tamper switch with two screws using a medium Phillips screwdriver
Instruction
Published
10/03/2023 11:56 AM
9300 - Reseal holes with RTV following tamper switch installation.
Remark
Published
10/03/2023 1:02 PM
9324 - 9306 - Determine if replacement terminal ends match existing terminal ends; Remark:9301
Procedure Step
Published
10/03/2023 10:02 AM
9306 - Determine if replacement terminal ends match existing terminal ends
Instruction
Published
10/03/2023 11:55 AM
9301 - If the replacement terminal ends do not match the existing terminal ends, it may...
Remark
Published
10/03/2023 1:01 PM
9325 - 9307 - Remove ¼ inch (6mm) of insulation from tamper switch wire end using wire stripp...; Remark:9523
Procedure Step
Published
10/03/2023 10:02 AM
9307 - Remove ¼ inch (6mm) of insulation from tamper switch wire end using wire stripp...
Instruction
Published
10/03/2023 11:55 AM
9523 -
Remark
Published
10/04/2023 11:23 AM
9326 - 9308 - Insert tamper switch wire into terminal end and crimp using crimping tool; Remark:9522
Procedure Step
Published
10/03/2023 10:02 AM
9308 - Insert tamper switch wire into terminal end and crimp using crimping tool
Instruction
Published
10/03/2023 11:54 AM
9522 -
Remark
Published
10/04/2023 11:24 AM
9327 - 9309 - Connect tamper switch to existing wiring using terminal end connectors; Remark:9521
Procedure Step
Published
10/03/2023 10:02 AM
9309 - Connect tamper switch to existing wiring using terminal end connectors
Instruction
Published
10/03/2023 10:42 AM
9521 -
Remark
Published
10/04/2023 11:25 AM
7279 - 7249 - Return equipment to normal operating condition; Remark:
Procedure Step
Published
04/27/2023 4:13 PM
7249 - Return equipment to normal operating condition
Instruction
Published
04/08/2025 3:22 PM
7280 - 7250 - Power on RPM; Remark:7251
Procedure Step
Published
04/27/2023 4:14 PM
7250 - Power on RPM
Instruction
Published
05/01/2023 8:31 AM
7251 - Move LD-260 switch to ON position. The LED PWR ON
Remark
Published
05/10/2023 3:14 PM
9318 - 9312 - Verify Control pillar tamper switch is operational; Remark:9302
Procedure Step
Published
10/03/2023 10:04 AM
9312 - Verify Control pillar tamper switch is operational
Instruction
Published
10/03/2023 10:41 AM
9302 - Open and close each door of the Control pillar, ensuring that the LED fault ligh...
Remark
Published
10/03/2023 1:01 PM
9319 - 9313 - Verify Auxiliary pillar tamper switch is ...; Remark:9303
Procedure Step
Published
10/03/2023 10:04 AM
9313 - Verify Auxiliary pillar tamper switch is operational
Instruction
Published
10/03/2023 10:40 AM
9303 - Open and close each door of the Auxiliary pillar, ensuring that the LED fault li...
Remark
Published
10/03/2023 1:01 PM
7281 - 7252 - Verify RPM start-up; Remark:7253
Procedure Step
Published
04/20/2025 3:26 PM
7252 - Verify RPM start-up
Instruction
Published
04/27/2023 2:23 PM
7253 - RPM will perform a power on self-test (POST) and collect a background radiati...
Remark
Published
05/10/2023 3:14 PM
7282 - 7254 - Confirm network connection; Remark:7255
Procedure Step
Published
04/27/2023 4:15 PM
7254 - Confirm network connection
Instruction
Published
04/27/2023 2:22 PM
7255 - Contact operators to confirm communications have been reestablished between RPM ...
Remark
Published
05/10/2023 3:15 PM
7283 - 7256 - Close and lock all RPM doors; Remark:
Procedure Step
Published
09/01/2023 11:45 PM
7256 - Close and lock all RPM doors
Instruction
Published
04/27/2023 2:21 PM
7842 - 7820 - Inform system operators upon completion of maintenance action; Remark:
Procedure Step
Published
07/07/2023 11:15 PM
7820 - Inform system operators upon completion of maintenance action
Instruction
Published
07/07/2023 10:02 PM
322 - 321 - Document maintenance actions; Remark:
Procedure Step
Published
06/17/2021 9:49 AM
321 - Document maintenance actions
Instruction
Published
04/21/2025 11:19 AM
2869 - 2585 - Document maintenance performed; Remark:2866
Procedure Step
Published
06/18/2021 5:58 PM
2585 - Document maintenance performed
Instruction
Published
07/09/2021 12:15 PM
2866 - Record observations, times, and results for the maintenance report.
Remark
Published
04/21/2025 11:39 AM
4706 - 4705 - Submit report; Remark:4864
Procedure Step
Published
06/29/2022 9:50 AM
4705 - Submit report
Instruction
Published
06/29/2022 9:50 AM
4864 - As specified by management or contractual obligations.
Remark
Published
07/28/2022 1:36 PM
Corrective Maintenance Procedure
Document Type
Published
03/02/2020 3:32 PM
1 hour
Duration
Published
04/01/2020 11:35 AM
Upon failure of tamper switch.
Frequency
Published
10/03/2023 10:08 AM
Upon intermittent tamper fault indicator.
Frequency
Published
10/03/2023 10:08 AM
Warning
Annotation Type
Published
03/02/2020 3:25 PM
Note
Annotation Type
Published
03/02/2020 3:25 PM
Caution
Annotation Type
Published
03/02/2020 3:24 PM
Technician 1
Skill Level
Published
05/14/2020 2:56 PM
Medium Phillips (PH2) screwdriver bit
Tools
Published
07/01/2022 11:18 AM
Measuring Tape
Tools
Published
10/03/2023 10:11 AM
Wire crimping tool
Tools
Published
09/25/2023 4:20 PM
Wire stripper
Tools
Published
09/25/2023 4:20 PM
Ladder; 2 meters, 6 feet tall; non-conducting if required
Replacement Parts
Published
07/02/2023 4:48 PM
Orange traffic cones
Replacement Parts
Published
04/27/2023 6:56 PM
Portable drill (if necessary)
Tools
Published
10/03/2023 10:11 AM
Mounting screw size (M3 x .5 metric or 4-40 UNC) and associated drill bit of matching size
Tools
Published
10/03/2023 10:12 AM
Tap- metric or standard (if necessary)
Tools
Published
10/03/2023 10:13 AM
Safety glasses if applicable
Replacement Parts
Published
06/29/2023 5:46 PM
LD-260 Disconnect Switch Power Off
படம்
Published
04/24/2023 12:49 PM
Measure distance from inside edge of cabinet to edge of tamper switch
படம்
Published
10/04/2023 11:10 AM
Measure distance from inside edge of door to edge of magnet
படம்
Published
10/04/2023 11:12 AM
Remove two screws of tamper switch using a medium Phillips screwdriver
படம்
Published
10/04/2023 11:14 AM
Determine if replacement terminal ends match existing terminal ends
படம்
Published
10/04/2023 11:13 AM
Remove ¼ inch (6mm) of insulation from tamper switch wire end using wire stripper
படம்
Published
10/04/2023 11:15 AM
Insert tamper switch wire into terminal end and crimp using crimping tool
படம்
Published
10/04/2023 11:15 AM
Connect tamper switch to existing wiring using terminal end connectors
படம்
Published
10/04/2023 11:16 AM
LD-260 Disconnect Switch Power On
படம்
Published
05/04/2023 3:37 PM