Rapiscan CM-267 Conveyor Monitor |
Device
|
Published
|
06/27/2024 1:02 PM
|
Rapiscan PM-700 Pedestrian Monitor |
Device
|
Published
|
06/20/2024 11:38 AM
|
Rapiscan TM-850 Rail Monitor |
Device
|
Published
|
09/18/2024 10:28 AM
|
Rapiscan VM-250 Vehicle Monitor |
Device
|
Published
|
10/14/2024 9:50 AM
|
9339 - 1401 - Establish Initial Conditions; Remark: |
Procedure Step
|
Published
|
10/03/2023 9:55 AM
|
1401 - Establish Initial Conditions |
Instruction
|
Published
|
09/30/2022 3:14 PM
|
7268 - 7231 - Close lane; Remark:7233 |
Procedure Step
|
Published
|
04/27/2023 7:01 PM
|
9053 - Warning : Traffic should temporarily be rerouted or halted during conduction of this pr... |
Annotation
|
Published
|
09/27/2023 9:09 AM
|
7231 - Close lane |
Instruction
|
Published
|
04/18/2023 1:00 PM
|
7233 - Use orange safety (traffic control) cones to setup barriers. Practice establi... |
Remark
|
Published
|
04/24/2023 12:18 PM
|
7269 - 7232 - Open RPM door; Remark:7234 |
Procedure Step
|
Published
|
04/27/2023 7:02 PM
|
7232 - Open RPM door |
Instruction
|
Published
|
04/18/2023 1:02 PM
|
7234 - Open all doors needed to access components. |
Remark
|
Published
|
04/19/2025 7:48 PM
|
7270 - 7235 - Power off RPM; Remark:7236 |
Procedure Step
|
Published
|
09/01/2023 7:57 PM
|
7235 - Power off RPM |
Instruction
|
Published
|
04/24/2023 12:30 PM
|
7236 - Move LD-260 switch to OFF position. The PWR ON |
Remark
|
Published
|
04/27/2023 4:25 PM
|
9333 - 9237 - Verify Alignment of Tamper Switch and Magnet; Remark: |
Procedure Step
|
Published
|
10/03/2023 9:58 AM
|
9291 - Note : Depending on the age and model of RPM, the tamper switch may be held in place by... |
Annotation
|
Published
|
10/03/2023 10:38 AM
|
9292 - Note : The troubleshooting process should determine if the reed switch is bad, or if th... |
Annotation
|
Published
|
10/03/2023 10:36 AM
|
9237 - Verify Alignment of Tamper Switch and Magnet |
Instruction
|
Published
|
10/03/2023 12:01 PM
|
9329 - 9238 - Measure distance from inside edge of cabinet to edge of tamper switch; Remark:9296 |
Procedure Step
|
Published
|
10/03/2023 9:59 AM
|
9238 - Measure distance from inside edge of cabinet to edge of tamper switch |
Instruction
|
Published
|
10/03/2023 11:59 AM
|
9296 - There is no predetermined position of a tamper switch. The switch may be located... |
Remark
|
Published
|
10/03/2023 1:04 PM
|
9330 - 9239 - Measure distance from inside edge of door to edge of magnet; Remark:9297 |
Procedure Step
|
Published
|
10/03/2023 9:59 AM
|
9239 - Measure distance from inside edge of door to edge of magnet |
Instruction
|
Published
|
10/03/2023 11:58 AM
|
9297 - The location of the magnet is determined by the location of the tamper switch. |
Remark
|
Published
|
10/03/2023 1:03 PM
|
9331 - 9240 - Verify alignment of tamper switch and mag...; Remark:9298 |
Procedure Step
|
Published
|
10/03/2023 10:00 AM
|
9240 - Verify alignment of tamper switch and magnet |
Instruction
|
Published
|
10/03/2023 11:58 AM
|
9298 - The alignment of the magnet and the tamper switch need to be within 6 mm (1/4 in... |
Remark
|
Published
|
10/03/2023 1:03 PM
|
9332 - 9241 - Relocate tamper switch or magnet to corre...; Remark:9299 |
Procedure Step
|
Published
|
10/03/2023 10:00 AM
|
9293 - Note : Consider relocating the tamper switch, rather than the magnet, to minimize numbe... |
Annotation
|
Published
|
10/03/2023 10:36 AM
|
9294 - Caution : Wear safety glasses as appropriate. |
Annotation
|
Published
|
10/03/2023 10:35 AM
|
9241 - Relocate tamper switch or magnet to correct any misalignment, if necessary |
Instruction
|
Published
|
10/03/2023 11:58 AM
|
9299 - Drill and tap new holes that align the tamper switch to the magnet using a porta... |
Remark
|
Published
|
10/03/2023 1:02 PM
|
9328 - 9242 - Tamper Switch Replacement and Wiring Connection; Remark: |
Procedure Step
|
Published
|
10/03/2023 10:01 AM
|
9242 - Tamper Switch Replacement and Wiring Connection |
Instruction
|
Published
|
10/03/2023 11:57 AM
|
9322 - 9304 - Remove two screws of tamper switch using a medium Phillips screwdriver; Remark:9524 |
Procedure Step
|
Published
|
10/03/2023 10:01 AM
|
9304 - Remove two screws of tamper switch using a medium Phillips screwdriver |
Instruction
|
Published
|
10/03/2023 11:56 AM
|
9524 - |
Remark
|
Published
|
10/04/2023 11:21 AM
|
9323 - 9305 - Install new tamper switch with two screws...; Remark:9300 |
Procedure Step
|
Published
|
10/03/2023 10:01 AM
|
9305 - Install new tamper switch with two screws using a medium Phillips screwdriver |
Instruction
|
Published
|
10/03/2023 11:56 AM
|
9300 - Reseal holes with RTV following tamper switch installation. |
Remark
|
Published
|
10/03/2023 1:02 PM
|
9324 - 9306 - Determine if replacement terminal ends match existing terminal ends; Remark:9301 |
Procedure Step
|
Published
|
10/03/2023 10:02 AM
|
9306 - Determine if replacement terminal ends match existing terminal ends |
Instruction
|
Published
|
10/03/2023 11:55 AM
|
9301 - If the replacement terminal ends do not match the existing terminal ends, it may... |
Remark
|
Published
|
10/03/2023 1:01 PM
|
9325 - 9307 - Remove ¼ inch (6mm) of insulation from tamper switch wire end using wire stripp...; Remark:9523 |
Procedure Step
|
Published
|
10/03/2023 10:02 AM
|
9307 - Remove ¼ inch (6mm) of insulation from tamper switch wire end using wire stripp... |
Instruction
|
Published
|
10/03/2023 11:55 AM
|
9523 - |
Remark
|
Published
|
10/04/2023 11:23 AM
|
9326 - 9308 - Insert tamper switch wire into terminal end and crimp using crimping tool; Remark:9522 |
Procedure Step
|
Published
|
10/03/2023 10:02 AM
|
9308 - Insert tamper switch wire into terminal end and crimp using crimping tool |
Instruction
|
Published
|
10/03/2023 11:54 AM
|
9522 - |
Remark
|
Published
|
10/04/2023 11:24 AM
|
9327 - 9309 - Connect tamper switch to existing wiring using terminal end connectors; Remark:9521 |
Procedure Step
|
Published
|
10/03/2023 10:02 AM
|
9309 - Connect tamper switch to existing wiring using terminal end connectors |
Instruction
|
Published
|
10/03/2023 10:42 AM
|
9521 - |
Remark
|
Published
|
10/04/2023 11:25 AM
|
7279 - 7249 - Return equipment to normal operating condition; Remark: |
Procedure Step
|
Published
|
04/27/2023 4:13 PM
|
7249 - Return equipment to normal operating condition |
Instruction
|
Published
|
04/08/2025 3:22 PM
|
7280 - 7250 - Power on RPM; Remark:7251 |
Procedure Step
|
Published
|
04/27/2023 4:14 PM
|
7250 - Power on RPM |
Instruction
|
Published
|
05/01/2023 8:31 AM
|
7251 - Move LD-260 switch to ON position. The LED PWR ON |
Remark
|
Published
|
05/10/2023 3:14 PM
|
9318 - 9312 - Verify Control pillar tamper switch is operational; Remark:9302 |
Procedure Step
|
Published
|
10/03/2023 10:04 AM
|
9312 - Verify Control pillar tamper switch is operational |
Instruction
|
Published
|
10/03/2023 10:41 AM
|
9302 - Open and close each door of the Control pillar, ensuring that the LED fault ligh... |
Remark
|
Published
|
10/03/2023 1:01 PM
|
9319 - 9313 - Verify Auxiliary pillar tamper switch is ...; Remark:9303 |
Procedure Step
|
Published
|
10/03/2023 10:04 AM
|
9313 - Verify Auxiliary pillar tamper switch is operational |
Instruction
|
Published
|
10/03/2023 10:40 AM
|
9303 - Open and close each door of the Auxiliary pillar, ensuring that the LED fault li... |
Remark
|
Published
|
10/03/2023 1:01 PM
|
7281 - 7252 - Verify RPM start-up; Remark:7253 |
Procedure Step
|
Published
|
04/20/2025 3:26 PM
|
7252 - Verify RPM start-up |
Instruction
|
Published
|
04/27/2023 2:23 PM
|
7253 - RPM will perform a power on self-test (POST) and collect a background radiati... |
Remark
|
Published
|
05/10/2023 3:14 PM
|
7282 - 7254 - Confirm network connection; Remark:7255 |
Procedure Step
|
Published
|
04/27/2023 4:15 PM
|
7254 - Confirm network connection |
Instruction
|
Published
|
04/27/2023 2:22 PM
|
7255 - Contact operators to confirm communications have been reestablished between RPM ... |
Remark
|
Published
|
05/10/2023 3:15 PM
|
7283 - 7256 - Close and lock all RPM doors; Remark: |
Procedure Step
|
Published
|
09/01/2023 11:45 PM
|
7256 - Close and lock all RPM doors |
Instruction
|
Published
|
04/27/2023 2:21 PM
|
7842 - 7820 - Inform system operators upon completion of maintenance action; Remark: |
Procedure Step
|
Published
|
07/07/2023 11:15 PM
|
7820 - Inform system operators upon completion of maintenance action |
Instruction
|
Published
|
07/07/2023 10:02 PM
|
322 - 321 - Document maintenance actions; Remark: |
Procedure Step
|
Published
|
06/17/2021 9:49 AM
|
321 - Document maintenance actions |
Instruction
|
Published
|
04/21/2025 11:19 AM
|
2869 - 2585 - Document maintenance performed; Remark:2866 |
Procedure Step
|
Published
|
06/18/2021 5:58 PM
|
2585 - Document maintenance performed |
Instruction
|
Published
|
07/09/2021 12:15 PM
|
2866 - Record observations, times, and results for the maintenance report. |
Remark
|
Published
|
04/21/2025 11:39 AM
|
4706 - 4705 - Submit report; Remark:4864 |
Procedure Step
|
Published
|
06/29/2022 9:50 AM
|
4705 - Submit report |
Instruction
|
Published
|
06/29/2022 9:50 AM
|
4864 - As specified by management or contractual obligations. |
Remark
|
Published
|
07/28/2022 1:36 PM
|
Corrective Maintenance Procedure |
Document Type
|
Published
|
03/02/2020 3:32 PM
|
1 hour |
Duration
|
Published
|
04/01/2020 11:35 AM
|
Upon failure of tamper switch. |
Frequency
|
Published
|
10/03/2023 10:08 AM
|
Upon intermittent tamper fault indicator. |
Frequency
|
Published
|
10/03/2023 10:08 AM
|
Warning |
Annotation Type
|
Published
|
03/02/2020 3:25 PM
|
Note |
Annotation Type
|
Published
|
03/02/2020 3:25 PM
|
Caution |
Annotation Type
|
Published
|
03/02/2020 3:24 PM
|
Technician 1 |
Skill Level
|
Published
|
05/14/2020 2:56 PM
|
Medium Phillips (PH2) screwdriver bit |
Tools
|
Published
|
07/01/2022 11:18 AM
|
Measuring Tape |
Tools
|
Published
|
10/03/2023 10:11 AM
|
Wire crimping tool |
Tools
|
Published
|
09/25/2023 4:20 PM
|
Wire stripper |
Tools
|
Published
|
09/25/2023 4:20 PM
|
Ladder; 2 meters, 6 feet tall; non-conducting if required |
Replacement Parts
|
Published
|
07/02/2023 4:48 PM
|
Orange traffic cones |
Replacement Parts
|
Published
|
04/27/2023 6:56 PM
|
Portable drill (if necessary) |
Tools
|
Published
|
10/03/2023 10:11 AM
|
Mounting screw size (M3 x .5 metric or 4-40 UNC) and associated drill bit of matching size |
Tools
|
Published
|
10/03/2023 10:12 AM
|
Tap- metric or standard (if necessary) |
Tools
|
Published
|
10/03/2023 10:13 AM
|
Safety glasses if applicable |
Replacement Parts
|
Published
|
06/29/2023 5:46 PM
|
LD-260 Disconnect Switch Power Off |
படம்
|
Published
|
04/24/2023 12:49 PM
|
Measure distance from inside edge of cabinet to edge of tamper switch |
படம்
|
Published
|
10/04/2023 11:10 AM
|
Measure distance from inside edge of door to edge of magnet |
படம்
|
Published
|
10/04/2023 11:12 AM
|
Remove two screws of tamper switch using a medium Phillips screwdriver |
படம்
|
Published
|
10/04/2023 11:14 AM
|
Determine if replacement terminal ends match existing terminal ends |
படம்
|
Published
|
10/04/2023 11:13 AM
|
Remove ¼ inch (6mm) of insulation from tamper switch wire end using wire stripper |
படம்
|
Published
|
10/04/2023 11:15 AM
|
Insert tamper switch wire into terminal end and crimp using crimping tool |
படம்
|
Published
|
10/04/2023 11:15 AM
|
Connect tamper switch to existing wiring using terminal end connectors |
படம்
|
Published
|
10/04/2023 11:16 AM
|
LD-260 Disconnect Switch Power On |
படம்
|