RPM SPY-2 to IXIO-DT1 Occupancy Sensor Conversion

Last Updated: 04/24/2025 1:45 AM

The following table lists all the components that make up the document.

Title Type Status Last Updated
Rapiscan PM-700 Pedestrian Monitor
Device
Published
06/20/2024 11:38 AM
1402 - 7927 - Establish Initial Conditions; Remark:
Procedure Step
Published
09/30/2022 1:47 PM
7927 - Establish Initial Conditions
Instruction
Published
07/12/2023 12:23 AM
8972 - 7231 - Close lane; Remark:7415
Procedure Step
Published
09/25/2023 10:51 PM
7231 - Close lane
Instruction
Published
04/18/2023 1:00 PM
7415 - Re-route pedestrian traffic.
Remark
Published
06/02/2023 1:08 PM
7269 - 7232 - Open RPM door; Remark:7234
Procedure Step
Published
04/27/2023 7:02 PM
7232 - Open RPM door
Instruction
Published
04/18/2023 1:02 PM
7234 - Open all doors needed to access components.
Remark
Published
04/19/2025 7:48 PM
7454 - 7290 - Disable tamper switches; Remark:7416
Procedure Step
Published
06/02/2023 5:25 PM
7290 - Disable tamper switches
Instruction
Published
05/01/2023 8:14 AM
7416 - Use a magnet to disable tamper switches for all open doors. Use adhesive tape...
Remark
Published
06/02/2023 1:18 PM
7270 - 7235 - Power off RPM; Remark:7236
Procedure Step
Published
09/01/2023 7:57 PM
7235 - Power off RPM
Instruction
Published
04/24/2023 12:30 PM
7236 - Move LD-260 switch to OFF position. The PWR ON
Remark
Published
04/27/2023 4:25 PM
7479 - 7417 - Prepare New Occupancy Sensor; Remark:
Procedure Step
Published
06/02/2023 6:13 PM
7417 - Prepare New Occupancy Sensor
Instruction
Published
06/02/2023 1:39 PM
7456 - 7418 - Remove cover from new occupancy sensor; Remark:7419
Procedure Step
Published
06/02/2023 5:27 PM
7418 - Remove cover from new occupancy sensor
Instruction
Published
06/02/2023 1:43 PM
7419 - Use a slotted screwdriver to pry the cover off from the side.
Remark
Published
04/13/2025 5:44 PM
7457 - 7420 - Verify narrow field radar antenna is installed; Remark:7421
Procedure Step
Published
04/13/2025 6:18 PM
7420 - Verify narrow field radar antenna is installed
Instruction
Published
04/13/2025 5:44 PM
7421 - The IXIO-DT1 should come with the narrow field antenna installed.
Remark
Published
06/02/2023 2:14 PM
8901 - If needed, the antenna can be changed. Remove cover. Install narrow field ant...
Remark
Published
09/25/2023 9:51 PM
8889 - 8888 - Prepare Mounting Holes; Remark:
Procedure Step
Published
09/25/2023 4:55 PM
8888 - Prepare Mounting Holes
Instruction
Published
09/25/2023 4:54 PM
8884 - 8883 - Mark mounting hole height; Remark:8882
Procedure Step
Published
09/25/2023 4:58 PM
8883 - Mark mounting hole height
Instruction
Published
09/25/2023 4:56 PM
8882 - Use erasable marker or pencil to draw a level horizontal line. Mounting hole ...
Remark
Published
09/25/2023 4:58 PM
8886 - 8879 - Mark centerline of pedestrian monitor door; Remark:8878
Procedure Step
Published
09/25/2023 5:01 PM
8879 - Mark centerline of pedestrian monitor door
Instruction
Published
09/25/2023 5:00 PM
8878 - Use erasable marker or pencil to draw a vertical line.
Remark
Published
09/25/2023 5:01 PM
8885 - 8881 - Attach mounting template; Remark:8880
Procedure Step
Published
09/25/2023 4:59 PM
8881 - Attach mounting template
Instruction
Published
09/25/2023 4:58 PM
8880 - Template provided with the IXIO-DT1 has a self-adhesive backing. Template may...
Remark
Published
09/25/2023 4:59 PM
8887 - 8877 - Mark location of 3.2-mm (1/8-inch) mounting holes; Remark:8876
Procedure Step
Published
09/25/2023 5:03 PM
8904 - Caution : Ensure placement of mounting holes will not interfere with internal wiring in...
Annotation
Published
09/25/2023 9:57 PM
8877 - Mark location of 3.2-mm (1/8-inch) mounting holes
Instruction
Published
09/25/2023 5:01 PM
8876 - If available, use a center punch and hammer to create a dimple at each mounti...
Remark
Published
09/25/2023 5:01 PM
8905 - 8903 - Mark location of 8-mm (5/16-inch) hole for wire passage; Remark:8902
Procedure Step
Published
09/25/2023 9:58 PM
8903 - Mark location of 8-mm (5/16-inch) hole for wire passage
Instruction
Published
09/25/2023 9:58 PM
8902 - If available, use a center punch and hammer to create a dimple at center of w...
Remark
Published
09/25/2023 9:58 PM
8946 - 8945 - Drill Installation Holes; Remark:
Procedure Step
Published
09/25/2023 10:01 PM
8945 - Drill Installation Holes
Instruction
Published
09/25/2023 10:01 PM
8939 - 8938 - Hold or block the door in an open position; Remark:
Procedure Step
Published
09/25/2023 10:01 PM
8938 - Hold or block the door in an open position
Instruction
Published
09/25/2023 10:01 PM
8940 - 8935 - Drill two (2) mounting holes; Remark:8934
Procedure Step
Published
09/25/2023 10:02 PM
8936 - Warning : Wear protective gloves and eyewear when drilling into cabinet door.
Annotation
Published
09/25/2023 10:05 PM
8937 - Caution : Do not damage interior of RPM when drilling holes.
Annotation
Published
09/25/2023 10:05 PM
8935 - Drill two (2) mounting holes
Instruction
Published
09/25/2023 10:02 PM
8934 - Use a 3.2-mm (1/8-inch) drill bit.
Remark
Published
09/25/2023 10:02 PM
8941 - 8933 - Drill wire passage hole; Remark:8932
Procedure Step
Published
09/25/2023 10:03 PM
8933 - Drill wire passage hole
Instruction
Published
09/25/2023 10:03 PM
8932 - Use an 8-mm (5/16-inch) drill bit.
Remark
Published
09/25/2023 10:03 PM
8942 - 8931 - Clean newly drilled holes; Remark:8930
Procedure Step
Published
09/25/2023 10:04 PM
8931 - Clean newly drilled holes
Instruction
Published
09/25/2023 10:04 PM
8930 - Use the deburring tool
Remark
Published
09/25/2023 10:04 PM
8943 - 8929 - Partially insert two (2) screws into mounting holes; Remark:8928
Procedure Step
Published
09/25/2023 10:06 PM
8929 - Partially insert two (2) screws into mounting holes
Instruction
Published
09/25/2023 10:06 PM
8928 - Mounting screws are included in the IXIO-DT-1 kit. Do not fully tighten screw...
Remark
Published
09/25/2023 10:06 PM
8944 - 8926 - Insert rubber grommet in wire passage hole; Remark:8925
Procedure Step
Published
09/25/2023 10:08 PM
8927 - Note : Protecting wires with a rubber grommet is critical to preventing damage to wi...
Annotation
Published
09/25/2023 10:08 PM
8926 - Insert rubber grommet in wire passage hole
Instruction
Published
09/25/2023 10:07 PM
8925 - rubber grommet
Remark
Published
09/25/2023 10:08 PM
8924 - 8923 - Install IXIO-DT1 Sensor; Remark:
Procedure Step
Published
09/25/2023 10:09 PM
8923 - Install IXIO-DT1 Sensor
Instruction
Published
09/25/2023 10:09 PM
8918 - 8917 - Feed wiring connector through grommet; Remark:8915
Procedure Step
Published
09/25/2023 10:13 PM
8917 - Feed wiring connector through grommet
Instruction
Published
09/25/2023 10:11 PM
8915 - The wiring assembly is included in the IXIO-DT1 kit. Feed loose end of wiring...
Remark
Published
09/25/2023 10:11 PM
8916 - Leave approximately 15 cm (6 in) of wire remaining outside of cabinet.
Remark
Published
09/25/2023 10:13 PM
8919 - 8914 - Mount new sensor; Remark:8912
Procedure Step
Published
09/25/2023 10:15 PM
8914 - Mount new sensor
Instruction
Published
09/25/2023 10:13 PM
8912 - First, slide left side onto mounting screw.
Remark
Published
09/25/2023 10:14 PM
8913 - Then, place right side over mounting screw and push down.
Remark
Published
09/25/2023 10:15 PM
8920 - 8911 - Tighten two (2) mounting screws; Remark:8910
Procedure Step
Published
09/25/2023 10:16 PM
8911 - Tighten two (2) mounting screws
Instruction
Published
09/25/2023 10:15 PM
8910 - Use medium Phillips (PH2) screwdriver. Take care not to overtighten.
Remark
Published
09/25/2023 10:16 PM
8921 - 8909 - Route wiring through clamp and connect; Remark:8908
Procedure Step
Published
09/25/2023 10:18 PM
8909 - Route wiring through clamp and connect
Instruction
Published
09/25/2023 10:16 PM
8908 - route wiring through clamp and connect
Remark
Published
09/25/2023 10:18 PM
8922 - 8907 - Adjust angle of the radar antenna; Remark:8906
Procedure Step
Published
09/25/2023 10:20 PM
8907 - Adjust angle of the radar antenna
Instruction
Published
09/25/2023 10:18 PM
8906 - The angle is adjusted by manually rotating the antenna up or down. The defaul...
Remark
Published
09/25/2023 10:20 PM
8970 - 8969 - Connect Wiring to RPM; Remark:
Procedure Step
Published
09/25/2023 10:23 PM
8969 - Connect Wiring to RPM
Instruction
Published
09/25/2023 10:22 PM
8963 - 8962 - Disconnect existing SPY-2 wiring; Remark:8961
Procedure Step
Published
09/25/2023 10:25 PM
7351 - Note : It is good practice to verify all cables and connectors are labeled prior to ...
Annotation
Published
05/03/2023 11:25 AM
8962 - Disconnect existing SPY-2 wiring
Instruction
Published
09/25/2023 10:24 PM
8961 - Do not remove existing occupancy sensor from door panel. Disconnect SPY-2 wir...
Remark
Published
09/25/2023 10:24 PM
8964 - 8960 - Route new cable to TB2; Remark:8959
Procedure Step
Published
09/25/2023 10:26 PM
8960 - Route new cable to TB2
Instruction
Published
09/25/2023 10:25 PM
8959 - New IXIO-DT1 cable should be routed along existing SPY-2 cable. Cable ties ma...
Remark
Published
09/25/2023 10:26 PM
8965 - 8958 - Connect red wire to TB2, Pin 16; Remark:8956
Procedure Step
Published
09/25/2023 10:30 PM
7263 - Caution : Correct placement of connectors and wiring is critical to proper operation.
Annotation
Published
04/24/2023 2:32 PM
8958 - Connect red wire to TB2, Pin 16
Instruction
Published
09/25/2023 10:27 PM
8956 - Red is power (+12 VDC) wire.
Remark
Published
09/25/2023 10:29 PM
8957 - For models with older terminal blocks, it may be necessary to use a fork conn...
Remark
Published
09/25/2023 10:30 PM
8966 - 8955 - Connect both black and white wires to TB2, Pin 15; Remark:8954
Procedure Step
Published
09/25/2023 10:32 PM
8955 - Connect both black and white wires to TB2, Pin 15
Instruction
Published
09/25/2023 10:31 PM
8954 - Black is the ground wire. White is the common wire
Remark
Published
09/25/2023 10:32 PM
8967 - 8953 - Connect green wire to TB2, Pin 6; Remark:8952
Procedure Step
Published
09/25/2023 10:34 PM
8953 - Connect green wire to TB2, Pin 6
Instruction
Published
09/25/2023 10:33 PM
8952 - Green is the occupancy signal to the SCA-775 module.
Remark
Published
09/25/2023 10:34 PM
8968 - 8951 - Apply sealant if needed; Remark:8950
Procedure Step
Published
09/25/2023 10:35 PM
8951 - Apply sealant if needed
Instruction
Published
09/25/2023 10:34 PM
8950 - Access wire penetration hole from back of the RPM door.
Remark
Published
09/25/2023 10:35 PM
7279 - 7249 - Return equipment to normal operating condition; Remark:
Procedure Step
Published
04/27/2023 4:13 PM
7249 - Return equipment to normal operating condition
Instruction
Published
04/08/2025 3:22 PM
8949 - 8948 - Hold door open; Remark:8947
Procedure Step
Published
09/25/2023 10:37 PM
8948 - Hold door open
Instruction
Published
09/25/2023 10:37 PM
8947 - Do not move door. Door must remain stationary to prevent occupancy.
Remark
Published
09/25/2023 10:37 PM
7280 - 7250 - Power on RPM; Remark:7251
Procedure Step
Published
04/27/2023 4:14 PM
7250 - Power on RPM
Instruction
Published
05/01/2023 8:31 AM
7251 - Move LD-260 switch to ON position. The LED PWR ON
Remark
Published
05/10/2023 3:14 PM
7468 - 7304 - Confirm RPM has restarted correctly; Remark:7487
Procedure Step
Published
06/02/2023 5:36 PM
7304 - Confirm RPM has restarted correctly
Instruction
Published
05/01/2023 8:31 AM
7487 - The SC-770 controller will display "OK" following Power On Self-Test (POST) a...
Remark
Published
06/02/2023 10:35 PM
7389 - 7254 - Confirm network connection; Remark:7255
Procedure Step
Published
05/04/2023 4:33 PM
7254 - Confirm network connection
Instruction
Published
04/27/2023 2:22 PM
7255 - Contact operators to confirm communications have been reestablished between RPM ...
Remark
Published
05/10/2023 3:15 PM
7470 - 7442 - Generate occupancy; Remark:7443
Procedure Step
Published
06/02/2023 5:37 PM
7442 - Generate occupancy
Instruction
Published
06/02/2023 4:19 PM
7443 - Create motion in front of occupancy sensor. While holding the door open and s...
Remark
Published
06/02/2023 4:21 PM
7471 - 7444 - Verify occupancy sensor functionality; Remark:7445
Procedure Step
Published
06/02/2023 5:38 PM
7444 - Verify occupancy sensor functionality
Instruction
Published
06/02/2023 4:32 PM
7445 - IXIO-DT1 green sensor light will illuminate.
Remark
Published
06/02/2023 4:35 PM
8973 - Left latch on the LCD screen will indicate a “closed” circuit.
Remark
Published
09/25/2023 11:05 PM
8974 - SC-770 status will read “OCCUPIED”.
Remark
Published
09/25/2023 11:06 PM
7472 - 7446 - Install sensor cover; Remark:7447
Procedure Step
Published
06/02/2023 5:38 PM
7446 - Install sensor cover
Instruction
Published
06/02/2023 4:37 PM
7447 - The cover should snap into place.
Remark
Published
06/02/2023 4:38 PM
7473 - 7448 - If needed, apply sealant; Remark:7449
Procedure Step
Published
06/02/2023 5:39 PM
7448 - If needed, apply sealant
Instruction
Published
06/02/2023 4:39 PM
7449 - If used outdoors, sealant should be applied to top and sides of cover. Do not...
Remark
Published
06/02/2023 4:41 PM
7474 - 7310 - Enable tamper switches; Remark:7451
Procedure Step
Published
06/02/2023 5:41 PM
7310 - Enable tamper switches
Instruction
Published
05/01/2023 8:36 AM
7451 - Remove magnets and/or adhesive tape from door tamper switches.
Remark
Published
04/13/2025 5:46 PM
7283 - 7256 - Close and lock all RPM doors; Remark:
Procedure Step
Published
09/01/2023 11:45 PM
7256 - Close and lock all RPM doors
Instruction
Published
04/27/2023 2:21 PM
7842 - 7820 - Inform system operators upon completion of maintenance action; Remark:
Procedure Step
Published
07/07/2023 11:15 PM
7820 - Inform system operators upon completion of maintenance action
Instruction
Published
07/07/2023 10:02 PM
322 - 321 - Document maintenance actions; Remark:
Procedure Step
Published
06/17/2021 9:49 AM
321 - Document maintenance actions
Instruction
Published
04/21/2025 11:19 AM
2869 - 2585 - Document maintenance performed; Remark:2866
Procedure Step
Published
06/18/2021 5:58 PM
2585 - Document maintenance performed
Instruction
Published
07/09/2021 12:15 PM
2866 - Record observations, times, and results for the maintenance report.
Remark
Published
04/21/2025 11:39 AM
4706 - 4705 - Submit report; Remark:4864
Procedure Step
Published
06/29/2022 9:50 AM
4705 - Submit report
Instruction
Published
06/29/2022 9:50 AM
4864 - As specified by management or contractual obligations.
Remark
Published
07/28/2022 1:36 PM
Corrective Maintenance Procedure
Document Type
Published
03/02/2020 3:32 PM
minutes
Duration
Published
05/26/2022 11:41 AM
Upon failure of the Visonic SPY-2 infrared curtain occupancy sensor
Frequency
Published
09/25/2023 3:49 PM
Caution
Annotation Type
Published
03/02/2020 3:24 PM
Warning
Annotation Type
Published
03/02/2020 3:25 PM
Note
Annotation Type
Published
03/02/2020 3:25 PM
Technician 2
Skill Level
Published
04/09/2020 1:17 AM
Keys to access RPM
Replacement Parts
Published
04/27/2023 6:56 PM
Magnets and adhesive tape to disable door tamper switches
Replacement Parts
Published
06/02/2023 10:08 PM
Medium Phillips (PH2) screwdriver
Tools
Published
04/24/2020 4:40 PM
Cordless drill
Tools
Published
09/25/2023 4:19 PM
3.2-mm (1/8-inch) drill bit (for metal)
Tools
Published
09/25/2023 4:19 PM
8-mm (5/16-inch) drill bit (for metal)
Tools
Published
09/25/2023 4:19 PM
Deburring tool
Tools
Published
09/25/2023 4:20 PM
safety glasses
Replacement Parts
Published
07/02/2023 4:48 PM
Gloves (heavy duty)
Tools
Published
09/25/2023 4:20 PM
Wire stripper
Tools
Published
09/25/2023 4:20 PM
Wire crimping tool
Tools
Published
09/25/2023 4:20 PM
Orange/yellow safety vest
Replacement Parts
Published
04/27/2023 6:56 PM
Safety shoes
Replacement Parts
Published
04/27/2023 6:56 PM
Protective headwear: glasses, hard hat
Replacement Parts
Published
05/10/2023 3:31 PM
Orange traffic cones
Replacement Parts
Published
04/27/2023 6:56 PM
Disable tamper switch
படம்
Published
09/07/2023 8:22 PM
Disable Tamper Switch
படம்
Published
06/02/2023 2:28 PM
LD-260 Disconnect Switch Power Off
படம்
Published
04/24/2023 12:49 PM
Remove Occupancy Sensor Cover
படம்
Published
06/02/2023 2:38 PM
The IXIO-DT1 should come with the narrow field antenna installed
படம்
Published
09/25/2023 8:35 PM
Verify narrow field radar antenna is installed
படம்
Published
09/25/2023 8:38 PM
Verify narrow field radar antenna is installed 2
படம்
Published
09/25/2023 8:39 PM
Mark mounting hole height
படம்
Published
09/25/2023 8:40 PM
Mark centerline of pedestrian monitor door
படம்
Published
09/25/2023 8:42 PM
Attach mounting template
படம்
Published
09/25/2023 8:44 PM
Mark location of 3.2-mm (1/8-inch) mounting holes
படம்
Published
09/25/2023 8:46 PM
Mark location of 8-mm (5/16-inch) hole for wire passage
படம்
Published
09/25/2023 8:47 PM
Insert rubber grommet in wire passage hole
படம்
Published
09/25/2023 8:48 PM
Feed wiring connector through grommet
படம்
Published
09/25/2023 8:50 PM
Feed wiring connector through grommet2
படம்
Published
09/25/2023 8:51 PM
Mount new sensor
படம்
Published
09/25/2023 8:52 PM
Mount new sensor2
படம்
Published
09/25/2023 8:53 PM
Tighten two (2) mounting screws
படம்
Published
09/25/2023 8:54 PM
Route wiring through clamp and connect
படம்
Published
09/25/2023 8:55 PM
Adjust angle of the radar antenna
படம்
Published
09/25/2023 8:56 PM
Adjust angle of the radar antenna2
படம்
Published
09/25/2023 8:58 PM
Disconnect existing SPY-2 wiring
படம்
Published
09/25/2023 8:59 PM
Route new cable to TB2
படம்
Published
09/25/2023 9:01 PM
Connect red wire to TB2, Pin 16
படம்
Published
09/25/2023 9:02 PM
Connect red wire to TB2, Pin 16 (2)
படம்
Published
09/25/2023 9:03 PM
fork connector
படம்
Published
09/25/2023 9:04 PM
Connect both black and white wires to TB2, Pin 15
படம்
Published
09/25/2023 9:06 PM
Connect green wire to TB2, Pin 6
படம்
Published
09/25/2023 9:34 PM
Apply sealant if needed
படம்
Published
09/25/2023 9:36 PM
LD-260 Disconnect Switch Power On
படம்
Published
05/04/2023 3:37 PM
IXIO-DT1 green sensor light will illuminate
படம்
Published
09/25/2023 9:37 PM
Verify occupancy sensor functionality
படம்
Published
09/25/2023 9:38 PM
Verify occupancy sensor functionality2
படம்
Published
09/25/2023 9:39 PM
Install Occupancy Sensor Cover
படம்
Published
06/02/2023 4:26 PM
Occupancy Sensor Sealant Application
படம்
Published
06/02/2023 4:30 PM
Remove Magnet from Tamper.PNG
படம்
Published
09/28/2023 9:37 AM
Remove Magnet on Tamper Switch
படம்
Published
06/02/2023 4:31 PM