radEAGLET Operational Test

Last Updated: 04/24/2025 1:46 AM

The following table lists all the components that make up the document.

Title Type Status Last Updated
ORTEC radEAGLET-R 2SG
Device
Published
10/08/2024 1:48 PM
247 - 257 - Prepare instrument; Remark:
Procedure Step
Published
04/11/2025 9:08 PM
257 - Prepare instrument
Instruction
Published
04/11/2025 9:07 PM
786 - 219 - Verify there are no sources of radiation near instrument; Remark:7
Procedure Step
Published
04/20/2025 6:37 PM
219 - Verify there are no sources of radiation near instrument
Instruction
Published
04/12/2025 4:20 PM
7 - No Radiation symbol
Remark
Published
07/12/2021 1:34 PM
10880 - 10722 - Place instrument next to calibration block; Remark:10720
Procedure Step
Published
07/25/2024 9:39 PM
10722 - Place instrument next to calibration block
Instruction
Published
07/19/2024 2:28 PM
10720 - This is not required for models with an internal Cesium-137 (Cs-137) source. ...
Remark
Published
07/19/2024 2:28 PM
10879 - radEAGLET Next to calibration block
Remark
Published
09/25/2024 8:47 PM
10881 - 220 - Power on instrument; Remark:10718
Procedure Step
Published
07/25/2024 9:44 PM
220 - Power on instrument
Instruction
Published
04/06/2025 7:00 PM
10718 - Hold power button for about 2 seconds.
Remark
Published
07/19/2024 2:35 PM
10878 - radEAGLET Power instrument on
Remark
Published
09/26/2024 6:51 PM
10728 - 612 - Wait for instrument to complete start-up sequence; Remark:10713
Procedure Step
Published
04/13/2025 6:58 PM
612 - Wait for instrument to complete start-up sequence
Instruction
Published
04/13/2025 6:38 PM
10713 - This may take 1-3 minutes.
Remark
Published
07/19/2024 2:45 PM
10714 - radEAGLET Start up instrument stabilizing
Remark
Published
09/26/2024 7:15 PM
10715 - radEAGLET Start up sequence
Remark
Published
09/26/2024 7:14 PM
10882 - 10712 - Verify sufficient battery charge; Remark:10710
Procedure Step
Published
07/25/2024 9:50 PM
10712 - Verify sufficient battery charge
Instruction
Published
07/19/2024 2:57 PM
10710 - A fully charged battery will last approximately 8 hours. Confirm remaining ba...
Remark
Published
07/19/2024 3:00 PM
10877 - radEAGLET Verify battery charge
Remark
Published
09/25/2024 9:56 PM
10730 - 10709 - Verify instrument is stabilized; Remark:10707
Procedure Step
Published
07/19/2024 3:04 PM
10709 - Verify instrument is stabilized
Instruction
Published
07/19/2024 3:02 PM
10707 - The instrument is stabilized when the icon is green.
Remark
Published
07/19/2024 3:03 PM
10708 - radEAGLET Verify instrument stablized
Remark
Published
09/25/2024 10:09 PM
2253 - 2208 - Acquire Background Measurement; Remark:
Procedure Step
Published
08/27/2024 4:49 PM
2208 - Acquire Background Measurement
Instruction
Published
04/06/2021 4:47 PM
10900 - 1437 - Verify Response to Gamma Source; Remark:
Procedure Step
Published
07/25/2024 10:12 PM
1437 - Verify Response to Gamma Source
Instruction
Published
09/01/2020 7:45 PM
10918 - 10672 - Verify instrument is in dose rate mode; Remark:10917
Procedure Step
Published
07/28/2024 2:45 PM
10672 - Verify instrument is in dose rate mode
Instruction
Published
07/19/2024 4:25 PM
10917 - radEAGLET verify instrument is in dose rate mode
Remark
Published
09/25/2024 10:07 PM
10896 - 235 - Place instrument next to radioactive gamma source; Remark:10895
Procedure Step
Published
07/25/2024 10:16 PM
235 - Place instrument next to radioactive gamma source
Instruction
Published
07/09/2021 1:39 PM
10895 - radEAGLET Next to radioactive gamma source
Remark
Published
09/26/2024 6:59 PM
10897 - 3097 - Verify instrument responds correctly; Remark:10889
Procedure Step
Published
07/25/2024 10:25 PM
3097 - Verify instrument responds correctly
Instruction
Published
07/16/2021 10:50 AM
10889 - Dose rate mode should respond as follows: • Gamma counts per second ...
Remark
Published
07/25/2024 10:18 PM
10890 - radEAGLET Background color will change
Remark
Published
09/26/2024 7:20 PM
10891 - • Gamma LED will flash
Remark
Published
07/25/2024 10:19 PM
10892 - radEAGLET Gamma LED will flash
Remark
Published
09/26/2024 7:22 PM
10893 - • Audible alarm will sound (if enabled) • Instrument will vibrate ...
Remark
Published
07/25/2024 10:23 PM
10894 - radEAGLET Instrument will vibrate
Remark
Published
09/26/2024 7:25 PM
10898 - 10888 - Move instrument away from radioactive source; Remark:10901
Procedure Step
Published
07/25/2024 10:30 PM
10888 - Move instrument away from radioactive source
Instruction
Published
07/25/2024 10:26 PM
10901 - radEAGLET Move instrument away from radioactive source
Remark
Published
09/26/2024 7:33 PM
10916 - 2209 - Verify instrument is in a suitable background radiation area; Remark:10693
Procedure Step
Published
07/28/2024 2:35 PM
2209 - Verify instrument is in a suitable background radiation area
Instruction
Published
06/11/2024 3:31 PM
10693 - The instrument should be located near the secondary inspection area, in simil...
Remark
Published
07/19/2024 3:12 PM
10915 - No source
Remark
Published
09/26/2024 7:36 PM
10899 - 10692 - Enter DETECT mode; Remark:10690
Procedure Step
Published
07/25/2024 10:33 PM
10695 - Note : Left, right, and down arrow Buttons will select screen options. The remainder...
Annotation
Published
07/19/2024 3:14 PM
10692 - Enter DETECT mode
Instruction
Published
07/19/2024 3:16 PM
10690 - Press down arrow to select DETECT.
Remark
Published
07/19/2024 3:16 PM
10885 - radEAGLET Enter DETECT mode
Remark
Published
09/26/2024 7:38 PM
10698 - 2220 - Wait for measurement to complete; Remark:10688
Procedure Step
Published
07/19/2024 3:23 PM
2220 - Wait for measurement to complete
Instruction
Published
10/22/2020 11:15 AM
10688 - This should take approximately 30 seconds. Instrument is ready when percentage b...
Remark
Published
07/19/2024 3:22 PM
10689 - radEAGLET Wait for measurement to complete
Remark
Published
09/26/2024 7:42 PM
10903 - 235 - Place instrument next to radioactive gamma source; Remark:10938
Procedure Step
Published
07/28/2024 11:53 AM
10938 - radEAGLET next to radioactive gamma source GREEN screen
Remark
Published
09/26/2024 7:49 PM
10912 - 3097 - Verify instrument responds correctly; Remark:10904
Procedure Step
Published
07/28/2024 12:09 PM
10904 - DETECT mode should respond as follows: • Gamma dose...
Remark
Published
07/28/2024 11:56 AM
10905 - radEAGLET Graph values will increase change to red
Remark
Published
09/26/2024 7:50 PM
10906 - radEAGLET Gamma LED will flash
Remark
Published
09/26/2024 7:51 PM
10907 - • Audible alerts will increase in pitch (if enabled) • Instrument ...
Remark
Published
07/28/2024 12:00 PM
10908 - radEAGLET Instrument will vibrate GRAPH screen
Remark
Published
09/26/2024 7:53 PM
10921 - 10888 - Move instrument away from radioactive source; Remark:10919
Procedure Step
Published
07/28/2024 2:56 PM
10919 - radEAGLET move instrument away from source red GRAPH screen
Remark
Published
09/26/2024 7:55 PM
10922 - 10680 - Exit DETECT mode; Remark:10923
Procedure Step
Published
07/28/2024 3:01 PM
10680 - Exit DETECT mode
Instruction
Published
07/19/2024 4:18 PM
10923 - Select EXIT
Remark
Published
07/28/2024 3:11 PM
10920 - radEAGLET Select EXIT
Remark
Published
09/27/2024 7:08 PM
10914 - 10913 - Verify Identification Performance; Remark:
Procedure Step
Published
07/28/2024 12:13 PM
10913 - Verify Identification Performance
Instruction
Published
07/28/2024 12:11 PM
10941 - 235 - Place instrument next to radioactive gamma source; Remark:10940
Procedure Step
Published
07/28/2024 7:51 PM
10940 - radEAGLET Next to radioactive gamma source
Remark
Published
09/27/2024 7:21 PM
10928 - 10672 - Verify instrument is in dose rate mode; Remark:10927
Procedure Step
Published
07/28/2024 3:56 PM
10927 - radEAGLET instrument is in dose rate mode
Remark
Published
09/27/2024 7:22 PM
10926 - 859 - Start identification measurement; Remark:10665
Procedure Step
Published
07/28/2024 3:48 PM
859 - Start identification measurement
Instruction
Published
10/26/2020 7:00 PM
10665 - Select EASY ID
Remark
Published
07/19/2024 4:28 PM
10924 - radeAGLET Select EASY ID
Remark
Published
09/27/2024 7:24 PM
10932 - Highlight Unknown and choose SELECT.
Remark
Published
07/28/2024 4:00 PM
10933 - radEAGLET Highlight Unknown and choose SELECT
Remark
Published
09/27/2024 7:29 PM
10934 - 2220 - Wait for measurement to complete; Remark:10737
Procedure Step
Published
07/28/2024 4:08 PM
10737 - The screen might prompt the operator to move the instrument away or towards t...
Remark
Published
07/20/2024 7:34 PM
10931 - radEAGLET Wait for measurement to complete
Remark
Published
09/27/2024 7:34 PM
10935 - 1442 - Verify identification results are correct; Remark:10929
Procedure Step
Published
07/28/2024 4:14 PM
1442 - Verify identification results are correct
Instruction
Published
09/02/2020 3:03 PM
10929 - Identification results should match the isotope(s) present.
Remark
Published
07/28/2024 4:10 PM
10930 - radEAGLET results should match isotope present
Remark
Published
09/27/2024 7:38 PM
10937 - 10749 - Exit EASY ID mode; Remark:10678
Procedure Step
Published
07/28/2024 7:41 PM
10749 - Exit EASY ID mode
Instruction
Published
07/20/2024 8:24 PM
10678 - Select EXIT
Remark
Published
07/19/2024 4:18 PM
10936 - radEAGLET Select EXIT
Remark
Published
09/27/2024 7:42 PM
253 - 242 - Document and report any unresolved problems; Remark:
Procedure Step
Published
06/22/2021 10:23 AM
242 - Document and report any unresolved problems
Instruction
Published
04/21/2025 11:45 AM
Routine Maintenance Procedure
Document Type
Published
03/02/2020 3:31 PM
minutes
Duration
Published
05/26/2022 11:41 AM
Annually
Frequency
Published
04/01/2020 11:37 AM
Before each use
Frequency
Published
08/31/2020 5:00 PM
Daily
Frequency
Published
04/01/2020 11:36 AM
Note
Annotation Type
Published
03/02/2020 3:25 PM
Technician 1
Skill Level
Published
05/14/2020 2:56 PM
None
Tools
Published
05/06/2020 9:50 PM
No Radiation Symbol
படம்
Published
08/13/2024 2:56 PM
radEAGLET Next to calibration block
படம்
Published
07/19/2024 4:32 PM
radEAGLET Power instrument on
படம்
Published
07/19/2024 4:32 PM
radEAGLET Start up instrument stabilizing
படம்
Published
07/19/2024 4:32 PM
radEAGLET start up sequence
படம்
Published
07/19/2024 4:32 PM
radEAGLET Verify battery charge
படம்
Published
07/19/2024 4:32 PM
radEAGLET Verify instrument stabilized
படம்
Published
07/19/2024 4:32 PM
radEAGLET start up sequence
படம்
Published
07/21/2024 3:26 PM
radEAGLET Next to radioactive gamma source
படம்
Published
07/25/2024 10:49 PM
radEAGLET Background color will change
படம்
Published
07/25/2024 10:49 PM
radEAGLET Gamma LED will flash
படம்
Published
07/25/2024 10:49 PM
radEAGLET instrument will vibrate
படம்
Published
07/28/2024 3:22 PM
radEAGLET Move instrument away from source
படம்
Published
07/26/2024 1:25 PM
No Source Found
படம்
Published
12/07/2023 2:54 PM
RadEAGLET Enter DETECT mode_V2.png
படம்
Published
07/20/2024 1:49 PM
radEAGLET Wait for measurement to complete
படம்
Published
07/19/2024 4:32 PM
radEAGLET next to radioactive gamma source GREEN screen
படம்
Published
07/28/2024 2:38 PM
radEAGLET Graph values will increase change to red
படம்
Published
07/28/2024 12:09 PM
radEAGLET Instrument will vibrate GRAPH.png
படம்
Published
07/25/2024 10:49 PM
radEAGLET move instrument away from source red GRAPH screen
படம்
Published
07/28/2024 3:01 PM
radEAGLET Select EXIT DETECT mode
படம்
Published
07/25/2024 9:20 PM
radEAGLET Verify instrument is in dose rate mode
படம்
Published
07/19/2024 4:32 PM
radEAGLET Select EASY ID
படம்
Published
07/19/2024 4:32 PM
radEAGLET Highlight Unknown and choose SELECT
படம்
Published
07/28/2024 4:14 PM
radEAGLET Wait for measurement to complete
படம்
Published
07/20/2024 7:54 PM
radEAGLET results should match isotope present
படம்
Published
07/28/2024 4:14 PM
radEAGLET Select EXIT
படம்
Published
07/20/2024 8:51 PM

radEAGLET Operation

Last Updated: 04/24/2025 1:46 AM

The following table lists all the components that make up the document.

Title Type Status Last Updated
ORTEC radEAGLET-R 2SG
Device
Published
10/08/2024 1:48 PM
247 - 257 - Prepare instrument; Remark:
Procedure Step
Published
04/11/2025 9:08 PM
257 - Prepare instrument
Instruction
Published
04/11/2025 9:07 PM
10725 - 10724 - Wear safety strap; Remark:10723
Procedure Step
Published
07/19/2024 2:24 PM
10724 - Wear safety strap
Instruction
Published
07/19/2024 2:22 PM
10723 - radEAGLET Wear safety strap
Remark
Published
09/28/2024 8:38 AM
786 - 219 - Verify there are no sources of radiation near instrument; Remark:7
Procedure Step
Published
04/20/2025 6:37 PM
219 - Verify there are no sources of radiation near instrument
Instruction
Published
04/12/2025 4:20 PM
7 - No Radiation symbol
Remark
Published
07/12/2021 1:34 PM
10726 - 10722 - Place instrument next to calibration block; Remark:10720
Procedure Step
Published
07/19/2024 2:30 PM
10722 - Place instrument next to calibration block
Instruction
Published
07/19/2024 2:28 PM
10720 - This is not required for models with an internal Cesium-137 (Cs-137) source. ...
Remark
Published
07/19/2024 2:28 PM
10721 - radEAGLET Next to calibration block
Remark
Published
09/28/2024 10:54 AM
10727 - 220 - Power on instrument; Remark:10718
Procedure Step
Published
07/19/2024 2:44 PM
220 - Power on instrument
Instruction
Published
04/06/2025 7:00 PM
10718 - Hold power button for about 2 seconds.
Remark
Published
07/19/2024 2:35 PM
10719 - radEAGLET Power instrument on
Remark
Published
09/28/2024 10:57 AM
10728 - 612 - Wait for instrument to complete start-up sequence; Remark:10713
Procedure Step
Published
04/13/2025 6:58 PM
612 - Wait for instrument to complete start-up sequence
Instruction
Published
04/13/2025 6:38 PM
10713 - This may take 1-3 minutes.
Remark
Published
07/19/2024 2:45 PM
10714 - radEAGLET Start up instrument stabilizing
Remark
Published
09/26/2024 7:15 PM
10715 - radEAGLET Start up sequence
Remark
Published
09/26/2024 7:14 PM
10729 - 10712 - Verify sufficient battery charge; Remark:10710
Procedure Step
Published
07/19/2024 3:01 PM
10717 - Note : If the screen dims due to inactivity, press any button once to wake up.
Annotation
Published
07/19/2024 2:49 PM
10712 - Verify sufficient battery charge
Instruction
Published
07/19/2024 2:57 PM
10710 - A fully charged battery will last approximately 8 hours. Confirm remaining ba...
Remark
Published
07/19/2024 3:00 PM
10711 - radEAGLET Verify battery charge
Remark
Published
09/28/2024 11:12 AM
10730 - 10709 - Verify instrument is stabilized; Remark:10707
Procedure Step
Published
07/19/2024 3:04 PM
10709 - Verify instrument is stabilized
Instruction
Published
07/19/2024 3:02 PM
10707 - The instrument is stabilized when the icon is green.
Remark
Published
07/19/2024 3:03 PM
10708 - radEAGLET Verify instrument stablized
Remark
Published
09/25/2024 10:09 PM
11051 - 3494 - Collect background measurement; Remark:10705
Procedure Step
Published
09/27/2024 8:51 PM
3494 - Collect background measurement
Instruction
Published
08/27/2024 5:25 PM
10705 - For instructions on performing a background measurement, refer to DET-HHD-ORT...
Remark
Published
04/13/2025 5:28 PM
410 - 7519 - Locate radioactive material; Remark:
Procedure Step
Published
04/13/2025 6:17 PM
7519 - Locate radioactive material
Instruction
Published
04/13/2025 5:47 PM
10696 - 2209 - Verify instrument is in a suitable background radiation area; Remark:10693
Procedure Step
Published
07/19/2024 3:14 PM
2209 - Verify instrument is in a suitable background radiation area
Instruction
Published
06/11/2024 3:31 PM
10693 - The instrument should be located near the secondary inspection area, in simil...
Remark
Published
07/19/2024 3:12 PM
10794 - No Radiation Sources
Remark
Published
09/28/2024 11:01 AM
10697 - 10692 - Enter DETECT mode; Remark:10690
Procedure Step
Published
07/19/2024 3:19 PM
10695 - Note : Left, right, and down arrow Buttons will select screen options. The remainder...
Annotation
Published
07/19/2024 3:14 PM
10692 - Enter DETECT mode
Instruction
Published
07/19/2024 3:16 PM
10690 - Press down arrow to select DETECT.
Remark
Published
07/19/2024 3:16 PM
10691 - radEAGLET Enter DETECT Mode
Remark
Published
09/28/2024 11:40 AM
10698 - 2220 - Wait for measurement to complete; Remark:10688
Procedure Step
Published
07/19/2024 3:23 PM
2220 - Wait for measurement to complete
Instruction
Published
10/22/2020 11:15 AM
10688 - This should take approximately 30 seconds. Instrument is ready when percentage b...
Remark
Published
07/19/2024 3:22 PM
10689 - radEAGLET Wait for measurement to complete
Remark
Published
09/26/2024 7:42 PM
10699 - 408 - Survey close to surface of item; Remark:388
Procedure Step
Published
07/19/2024 3:27 PM
408 - Survey close to surface of item
Instruction
Published
06/10/2021 8:50 PM
388 - Maintain a distance of approximately 5 to 10 cm from surface of item. Do not ...
Remark
Published
06/10/2021 8:49 PM
10687 - radEAGLET Survey close to surface
Remark
Published
09/27/2024 9:01 PM
10700 - 366 - Survey slowly over entire item; Remark:2315
Procedure Step
Published
07/19/2024 4:06 PM
366 - Survey slowly over entire item
Instruction
Published
06/11/2021 9:10 AM
2315 - Move instrument approximately 20 cm per second. Thoroughly survey all accessi...
Remark
Published
11/04/2020 5:09 PM
10686 - radEAGLET Survey slowly
Remark
Published
09/27/2024 9:06 PM
10701 - 367 - Observe instrument response; Remark:10684
Procedure Step
Published
07/19/2024 4:09 PM
367 - Observe instrument response
Instruction
Published
06/11/2021 9:21 AM
10684 - Use audible alerts, numerical values, and moving graph to locate sources of r...
Remark
Published
07/19/2024 4:07 PM
10685 - radEAGLET Observe response
Remark
Published
09/27/2024 9:09 PM
10702 - 10646 - Localize source of radiation; Remark:386
Procedure Step
Published
07/19/2024 4:12 PM
10646 - Localize source of radiation
Instruction
Published
06/14/2024 4:22 PM
386 - Use crosshair technique to localize.
Remark
Published
06/11/2021 9:20 AM
10683 - radEAGLET Localize source
Remark
Published
09/27/2024 9:11 PM
405 - 368 - Mark point(s) of interest; Remark:4277
Procedure Step
Published
04/20/2025 5:44 PM
368 - Mark point(s) of interest
Instruction
Published
06/11/2021 9:23 AM
4277 - Place a marker (tape, pencil, etc.) on points exhibiting elevated radiation. ...
Remark
Published
04/20/2025 5:37 PM
10704 - 10680 - Exit DETECT mode; Remark:10678
Procedure Step
Published
07/24/2024 1:36 PM
10680 - Exit DETECT mode
Instruction
Published
07/19/2024 4:18 PM
10678 - Select EXIT
Remark
Published
07/19/2024 4:18 PM
10679 - radEAGLET Selet EXIT
Remark
Published
09/27/2024 9:20 PM
10677 - 856 - Identify Isotopes; Remark:
Procedure Step
Published
07/19/2024 4:20 PM
856 - Identify Isotopes
Instruction
Published
07/23/2021 9:20 PM
10674 - 2218 - Place instrument close to measurement location; Remark:2325
Procedure Step
Published
07/19/2024 4:24 PM
2218 - Place instrument close to measurement location
Instruction
Published
04/06/2021 5:15 PM
2325 - The instrument should be as close as possible without making contact.
Remark
Published
07/23/2021 10:42 PM
10673 - radEAGLET Instrument close to location
Remark
Published
09/27/2024 9:22 PM
10943 - 10672 - Verify instrument is in dose rate mode; Remark:10942
Procedure Step
Published
07/29/2024 10:21 AM
10672 - Verify instrument is in dose rate mode
Instruction
Published
07/19/2024 4:25 PM
10942 - radEAGLET Verify instrument is in dose rate mode
Remark
Published
09/27/2024 9:28 PM
10676 - 859 - Start identification measurement; Remark:10665
Procedure Step
Published
07/19/2024 4:32 PM
859 - Start identification measurement
Instruction
Published
10/26/2020 7:00 PM
10665 - Select EASY ID
Remark
Published
07/19/2024 4:28 PM
10666 - radEAGLET Select EASY ID
Remark
Published
10/01/2024 5:36 PM
10667 - Highlight Unknown
Remark
Published
07/19/2024 4:29 PM
10668 - radEAGLET Highlight Unknown
Remark
Published
10/01/2024 5:38 PM
10669 - Choose SELECT
Remark
Published
07/19/2024 4:31 PM
10670 - radEAGLET Unknown choose SELECT
Remark
Published
10/01/2024 5:41 PM
10739 - 2220 - Wait for measurement to complete; Remark:10737
Procedure Step
Published
07/20/2024 7:37 PM
10737 - The screen might prompt the operator to move the instrument away or towards t...
Remark
Published
07/20/2024 7:34 PM
10738 - radEAGLET Wait for measurement to complete
Remark
Published
07/23/2024 6:16 PM
10740 - 2221 - Observe identification results; Remark:10735
Procedure Step
Published
07/20/2024 7:54 PM
2221 - Observe identification results
Instruction
Published
04/06/2021 5:20 PM
10735 - Identification results include: 1) identification confidence (1-10)
Remark
Published
07/20/2024 7:42 PM
10736 - radEAGLET Identification Results
Remark
Published
07/24/2024 11:35 AM
10750 - 10749 - Exit EASY ID mode; Remark:10678
Procedure Step
Published
07/20/2024 8:27 PM
10749 - Exit EASY ID mode
Instruction
Published
07/20/2024 8:24 PM
10748 - radEAGLET Select EXIT
Remark
Published
07/23/2024 5:57 PM
399 - 375 - Document results; Remark:394
Procedure Step
Published
06/11/2021 9:46 AM
375 - Document results
Instruction
Published
06/11/2021 9:37 AM
394 - Document results per Standard Operating Procedures.
Remark
Published
06/11/2021 9:36 AM
2248 - 313 - Power off instrument; Remark:10741
Procedure Step
Published
10/22/2020 12:22 PM
313 - Power off instrument
Instruction
Published
07/23/2021 2:41 PM
10741 - Select MENU
Remark
Published
07/20/2024 8:44 PM
10742 - radEAGLET Select MENU power off
Remark
Published
07/23/2024 6:13 PM
10743 - Highlight Shutdown
Remark
Published
07/20/2024 8:46 PM
10744 - radEAGLET Highlight Shutdown
Remark
Published
07/23/2024 5:59 PM
10745 - radEAGLET Choose Select for Shutdown
Remark
Published
07/23/2024 5:58 PM
10746 - Select OK
Remark
Published
07/20/2024 8:50 PM
10747 - radEAGLET Select OK
Remark
Published
07/23/2024 5:57 PM
10792 - 2370 - Connect to charger; Remark:10787
Procedure Step
Published
07/21/2024 12:40 PM
2370 - Connect to charger
Instruction
Published
04/06/2021 5:31 PM
10787 - The instrument has a wall charger and an automobile charger.
Remark
Published
07/21/2024 12:34 PM
10788 - radEAGLET Wall Charger and Charging Port
Remark
Published
07/23/2024 5:55 PM
10793 -
Remark
Published
07/21/2024 12:43 PM
10789 - Align the red dash with the top of the charging port.
Remark
Published
07/21/2024 12:36 PM
10790 - radEAGLET Align red dash charging port
Remark
Published
07/23/2024 5:54 PM
10791 - radEAGLET Align red dash charging port 2
Remark
Published
07/23/2024 5:41 PM
Operator Procedure
Document Type
Published
03/02/2020 3:31 PM
Note
Annotation Type
Published
03/02/2020 3:25 PM
None
Tools
Published
05/06/2020 9:50 PM
radEAGLET Wear safety strap
படம்
Published
07/19/2024 4:32 PM
No Radiation Symbol
படம்
Published
08/13/2024 2:56 PM
radEAGLET Next to calibration block
படம்
Published
07/19/2024 4:32 PM
radEAGLET Power instrument on
படம்
Published
07/19/2024 4:32 PM
radEAGLET Start up instrument stabilizing
படம்
Published
07/19/2024 4:32 PM
radEAGLET start up sequence
படம்
Published
07/19/2024 4:32 PM
radEAGLET Verify battery charge
படம்
Published
07/19/2024 4:32 PM
radEAGLET Verify instrument stabilized
படம்
Published
07/19/2024 4:32 PM
No Radiation Sources
படம்
Published
07/21/2024 2:10 PM
RadEAGLET Enter DETECT mode_V2.png
படம்
Published
07/20/2024 1:49 PM
radEAGLET Wait for measurement to complete
படம்
Published
07/19/2024 4:32 PM
radEAGLET Survey close to surface
படம்
Published
07/19/2024 4:32 PM
radEAGLET Survey slowly
படம்
Published
07/19/2024 4:32 PM
radEAGLET Observe response
படம்
Published
07/19/2024 4:32 PM
radEAGLET Localize source
படம்
Published
07/19/2024 4:32 PM
Mark_Source_Location_Trefoil
படம்
Published
02/19/2023 10:54 AM
radEAGLET Select EXIT DETECT mode
படம்
Published
07/25/2024 9:20 PM
radEAGLET Instrument close to location
படம்
Published
07/19/2024 4:32 PM
radEAGLET Verify instrument is in dose rate mode
படம்
Published
07/19/2024 4:32 PM
radEAGLET Select EASY ID
படம்
Published
07/19/2024 4:32 PM
radEAGLET Highlight Unknown
படம்
Published
07/19/2024 4:32 PM
radEAGLET Unknown choose SELECT
படம்
Published
07/19/2024 4:32 PM
radEAGLET Wait for measurement to complete
படம்
Published
07/20/2024 7:54 PM
radEAGLET Identification Results
படம்
Published
07/20/2024 7:54 PM
radEAGLET Select EXIT
படம்
Published
07/20/2024 8:51 PM
radEAGLET Select MENU
படம்
Published
07/25/2024 8:34 PM
radEAGLET Highlight Shutdown
படம்
Published
07/20/2024 8:51 PM
radEAGLET Choose Select for Shutdown
படம்
Published
07/20/2024 8:51 PM
radEAGLET Select OK
படம்
Published
07/20/2024 8:51 PM
radEAGLET Wall charger
படம்
Published
07/21/2024 12:40 PM
radEAGLET Charging port
படம்
Published
07/21/2024 12:40 PM
radEAGLET Align red dash charging port
படம்
Published
07/21/2024 12:40 PM
radEAGLET Align red dash charging port_2
படம்
Published
07/21/2024 12:40 PM

TA600 Radiation Pager Operational Test

Last Updated: 04/24/2025 1:43 AM

The following table lists all the components that make up the document.

Title Type Status Last Updated
Sensor Tech TA600 Radiation Pager
Device
Published
10/28/2024 3:51 PM
247 - 257 - Prepare instrument; Remark:
Procedure Step
Published
04/11/2025 9:08 PM
257 - Prepare instrument
Instruction
Published
04/11/2025 9:07 PM
786 - 219 - Verify there are no sources of radiation near instrument; Remark:7
Procedure Step
Published
04/20/2025 6:37 PM
219 - Verify there are no sources of radiation near instrument
Instruction
Published
04/12/2025 4:20 PM
7 - No Radiation symbol
Remark
Published
07/12/2021 1:34 PM
7555 - 220 - Power on instrument; Remark:7542
Procedure Step
Published
06/05/2023 5:57 PM
220 - Power on instrument
Instruction
Published
04/06/2025 7:00 PM
7542 - Set instrument to audio only mode.
Remark
Published
04/13/2025 5:48 PM
7556 - 612 - Wait for instrument to complete start-up sequence; Remark:7512
Procedure Step
Published
04/13/2025 6:50 PM
612 - Wait for instrument to complete start-up sequence
Instruction
Published
04/13/2025 6:38 PM
7512 - Red numerical LED display will flash while collecting background for 30 secon...
Remark
Published
10/19/2023 7:54 AM
7557 - 7543 - Test Audible Alarm; Remark:
Procedure Step
Published
06/05/2023 5:59 PM
7543 - Test Audible Alarm
Instruction
Published
06/05/2023 3:31 PM
7558 - 7544 - Place instrument next to source of radiation; Remark:7545
Procedure Step
Published
06/05/2023 5:59 PM
7544 - Place instrument next to source of radiation
Instruction
Published
06/05/2023 3:32 PM
7545 - TA600 Next to Source
Remark
Published
06/05/2023 3:34 PM
7559 - 2936 - Verify audible alarm functions correctly; Remark:7547
Procedure Step
Published
06/05/2023 6:00 PM
2936 - Verify audible alarm functions correctly
Instruction
Published
06/15/2021 4:09 PM
7547 - The instrument should respond as follows: Emit an audible b...
Remark
Published
06/05/2023 5:00 PM
7560 - 7548 - Acknowledge alarm; Remark:7549
Procedure Step
Published
06/05/2023 6:01 PM
7548 - Acknowledge alarm
Instruction
Published
06/05/2023 5:03 PM
7549 - Press display button to stop alarm. Otherwise, the alarm will automatically s...
Remark
Published
06/05/2023 5:07 PM
7561 - 7550 - Move instrument away from source of radiation; Remark:7551
Procedure Step
Published
06/05/2023 6:02 PM
7550 - Move instrument away from source of radiation
Instruction
Published
06/05/2023 5:09 PM
7551 - Move source away from TA600
Remark
Published
06/05/2023 5:12 PM
2914 - 2912 - Test vibration alarm; Remark:
Procedure Step
Published
06/06/2022 5:28 PM
2912 - Test vibration alarm
Instruction
Published
06/15/2021 4:11 PM
7562 - 7546 - Change to vibrate mode; Remark:7552
Procedure Step
Published
06/05/2023 6:02 PM
7546 - Change to vibrate mode
Instruction
Published
06/05/2023 3:35 PM
7552 - Set instrument to vibrate only mode.
Remark
Published
06/05/2023 5:15 PM
7563 - 612 - Wait for instrument to complete start-up sequence; Remark:7512
Procedure Step
Published
04/13/2025 6:55 PM
7553 - Note : If dial is turned to vibrate mode quickly, the instrument will not repeat sta...
Annotation
Published
06/05/2023 5:17 PM
7564 - 7544 - Place instrument next to source of radiation; Remark:7545
Procedure Step
Published
06/05/2023 6:05 PM
7565 - 2938 - Verify vibration alarm functions correctly; Remark:7554
Procedure Step
Published
06/05/2023 6:06 PM
2938 - Verify vibration alarm functions correctly
Instruction
Published
06/15/2021 4:12 PM
7554 - The instrument should respond as follows: Vibrate
Remark
Published
06/05/2023 5:24 PM
7566 - 7548 - Acknowledge alarm; Remark:7549
Procedure Step
Published
06/05/2023 6:07 PM
7567 - 7550 - Move instrument away from source of radiation; Remark:7551
Procedure Step
Published
06/05/2023 6:08 PM
253 - 242 - Document and report any unresolved problems; Remark:
Procedure Step
Published
06/22/2021 10:23 AM
242 - Document and report any unresolved problems
Instruction
Published
04/21/2025 11:45 AM
Routine Maintenance Procedure
Document Type
Published
03/02/2020 3:31 PM
Daily
Frequency
Published
04/01/2020 11:36 AM
Before each use
Frequency
Published
08/31/2020 5:00 PM
Note
Annotation Type
Published
03/02/2020 3:25 PM
Technician 1
Skill Level
Published
05/14/2020 2:56 PM
None
Tools
Published
05/06/2020 9:50 PM
No Radiation Symbol
படம்
Published
08/13/2024 2:56 PM
TA600 Audio Only
படம்
Published
06/04/2023 9:55 PM
TA600 Background
படம்
Published
06/04/2023 9:59 PM
TA600 Ready
படம்
Published
06/04/2023 9:59 PM
TA600 Next to Source
படம்
Published
03/29/2024 11:57 AM
TA600 Audible Alarm
படம்
Published
06/05/2023 5:00 PM
TA600 Acknowledge Alarm
படம்
Published
06/05/2023 5:07 PM
TA600 Away From Source
படம்
Published
06/05/2023 5:11 PM
TA600 Vibrate Only
படம்
Published
06/04/2023 9:56 PM
TA600 Vibration Alarm
படம்
Published
06/05/2023 5:23 PM

RadSeeker Calibration

Last Updated: 04/24/2025 1:42 AM

The following table lists all the components that make up the document.

Title Type Status Last Updated
Smiths Detection RadSeeker CS
Device
Published
06/27/2024 12:54 PM
5925 - 5924 - Prepare Calibration Source; Remark:
Procedure Step
Published
11/07/2022 1:09 PM
5924 - Prepare Calibration Source
Instruction
Published
11/07/2022 1:09 PM
5923 - 5922 - Position Eu-152 calibration source; Remark:5921
Procedure Step
Published
11/07/2022 1:21 PM
5922 - Position Eu-152 calibration source
Instruction
Published
11/07/2022 1:10 PM
5921 - Position Eu-152 source in front of the detector.
Remark
Published
11/07/2022 1:21 PM
5920 - 5919 - Calibrate Instrument; Remark:
Procedure Step
Published
11/07/2022 1:22 PM
5919 - Calibrate Instrument
Instruction
Published
11/07/2022 1:22 PM
5914 - 5913 - Enter Advanced Mode; Remark:5912
Procedure Step
Published
11/07/2022 1:24 PM
5913 - Enter Advanced Mode
Instruction
Published
11/07/2022 1:23 PM
5912 - Select Menu from the Detect screen. Scroll down to E...
Remark
Published
11/07/2022 1:24 PM
5915 - 5911 - Enter password; Remark:5910
Procedure Step
Published
11/07/2022 1:26 PM
5911 - Enter password
Instruction
Published
11/07/2022 1:25 PM
5910 - Enter default Nuclear Smuggling Detection and Deterrence (NSDD) password
Remark
Published
11/07/2022 1:26 PM
5916 - 5592 - Enter Service Mode; Remark:5909
Procedure Step
Published
11/07/2022 1:28 PM
5592 - Enter Service Mode
Instruction
Published
10/31/2022 11:37 AM
5909 - Select Enter Service Mode from the Advanced Mode menu.
Remark
Published
11/07/2022 1:28 PM
5917 - 5908 - Start calibration; Remark:5907
Procedure Step
Published
11/07/2022 1:31 PM
5908 - Start calibration
Instruction
Published
11/07/2022 1:30 PM
5907 - Select Calibrate Detector. Wait several minutes for the cali...
Remark
Published
11/07/2022 1:31 PM
5918 - 5906 - Confirm completion; Remark:5905
Procedure Step
Published
11/07/2022 1:32 PM
5906 - Confirm completion
Instruction
Published
11/07/2022 1:32 PM
5905 - The Calibrated message will appear indicating calibration is...
Remark
Published
11/07/2022 1:32 PM
5904 - 5903 - Prepare Instrument for Use; Remark:
Procedure Step
Published
11/07/2022 1:33 PM
5903 - Prepare Instrument for Use
Instruction
Published
11/07/2022 1:33 PM
5900 - 5899 - Exit Service Mode; Remark:5898
Procedure Step
Published
11/07/2022 1:35 PM
5899 - Exit Service Mode
Instruction
Published
11/07/2022 1:34 PM
5898 - Return Back to Service Mode options.
Remark
Published
11/07/2022 1:35 PM
5901 - 5897 - Select Exit Advanced Mode; Remark:5957
Procedure Step
Published
11/07/2022 1:36 PM
5897 - Select Exit Advanced Mode
Instruction
Published
11/07/2022 1:36 PM
5957 - IO RadSeeker Detect Screen Exit Advanced Mode
Remark
Published
11/15/2022 11:43 AM
5902 - 5896 - Restart Instrument; Remark:
Procedure Step
Published
11/07/2022 1:37 PM
5896 - Restart Instrument
Instruction
Published
11/07/2022 1:37 PM
322 - 321 - Document maintenance actions; Remark:
Procedure Step
Published
06/17/2021 9:49 AM
321 - Document maintenance actions
Instruction
Published
04/21/2025 11:19 AM
2869 - 2585 - Document maintenance performed; Remark:2866
Procedure Step
Published
06/18/2021 5:58 PM
2585 - Document maintenance performed
Instruction
Published
07/09/2021 12:15 PM
2866 - Record observations, times, and results for the maintenance report.
Remark
Published
04/21/2025 11:39 AM
4706 - 4705 - Submit report; Remark:4864
Procedure Step
Published
06/29/2022 9:50 AM
4705 - Submit report
Instruction
Published
06/29/2022 9:50 AM
4864 - As specified by management or contractual obligations.
Remark
Published
07/28/2022 1:36 PM
Corrective Maintenance Procedure
Document Type
Published
03/02/2020 3:32 PM
minutes
Duration
Published
05/26/2022 11:41 AM
As Needed
Frequency
Published
04/01/2020 11:36 AM
Technician 2
Skill Level
Published
04/09/2020 1:17 AM
None
Tools
Published
05/06/2020 9:50 PM
radseeker_di_front_rad_symbol.jpg
படம்
Published
10/10/2023 12:32 AM
radseeker_ui_detect_screen_menu.jpg
படம்
Published
10/10/2023 12:20 AM
radseeker_ui_detect_screen_enter_arrow.jpg
படம்
Published
10/10/2023 12:22 AM
radseeker_ui_detect_screen_password.jpg
படம்
Published
10/10/2023 12:14 AM
radseeker_ui_detect_screen_enter_service_mode.jpg
படம்
Published
10/10/2023 12:26 AM
radseeker_ui_detect_screen_calibrate_detector.jpg
படம்
Published
10/10/2023 12:27 AM
radseeker_ui_detect_screen_calibrated.jpg
படம்
Published
10/10/2023 12:26 AM
radseeker_ui_detect_screen_back_left_arrow.jpg
படம்
Published
10/10/2023 12:27 AM
radseeker_ui_detect_screen_back.jpg
படம்
Published
10/10/2023 12:28 AM
radseeker_ui_detect_screen_exit_advanced_mode.jpg
படம்
Published
10/10/2023 12:21 AM

PackEye Battery Cycle

Last Updated: 04/24/2025 1:42 AM

The following table lists all the components that make up the document.

Title Type Status Last Updated
Thermo FHT1377 PackEye
Device
Published
10/28/2024 3:37 PM
5690 - 5689 - Power Cycle Power Supply; Remark:
Procedure Step
Published
11/03/2022 10:35 AM
5689 - Power Cycle Power Supply
Instruction
Published
11/03/2022 10:35 AM
5758 - 205 - Disconnect charger; Remark:3946
Procedure Step
Published
11/03/2022 2:01 PM
205 - Disconnect charger
Instruction
Published
07/23/2021 2:42 PM
3946 - Rotate the collar counterclockwise and pull.
Remark
Published
04/12/2022 1:37 PM
3852 - 220 - Power on instrument; Remark:3836
Procedure Step
Published
03/29/2022 1:59 AM
220 - Power on instrument
Instruction
Published
04/06/2025 7:00 PM
3836 - Press power button on the indicator unit for approximately 1 second.
Remark
Published
03/29/2022 1:05 AM
5757 - 5756 - Wait for instrument to power off; Remark:5755
Procedure Step
Published
11/03/2022 2:00 PM
5756 - Wait for instrument to power off
Instruction
Published
11/03/2022 2:00 PM
5755 - This will discharge the battery. Time for this step is between 12 and 48 hour...
Remark
Published
11/03/2022 2:00 PM
5754 - 5753 - Reconnect charger; Remark:5751
Procedure Step
Published
11/03/2022 1:56 PM
5753 - Reconnect charger
Instruction
Published
11/03/2022 1:49 PM
5751 - IO PackEye Reconnect Charger Cable to Power Supply
Remark
Published
10/19/2024 4:44 PM
5752 - CHARGE (yellow) and READY (green) LEDs will...
Remark
Published
11/10/2022 9:17 AM
5750 - 5749 - Wait for instrument to completely charge; Remark:5748
Procedure Step
Published
11/03/2022 1:48 PM
5749 - Wait for instrument to completely charge
Instruction
Published
11/03/2022 1:47 PM
5748 - Time for this step is between 2 and 4 hours. Once fully charged, only the
Remark
Published
11/03/2022 1:48 PM
5688 - 5687 - Power Cycle Backup Battery; Remark:
Procedure Step
Published
11/03/2022 10:35 AM
5687 - Power Cycle Backup Battery
Instruction
Published
11/03/2022 10:35 AM
5747 - 5746 - Connect backup battery to charger; Remark:5745
Procedure Step
Published
11/03/2022 1:46 PM
5746 - Connect backup battery to charger
Instruction
Published
11/03/2022 1:45 PM
5745 - The backup battery uses a different charger than the PackEye.
Remark
Published
12/21/2022 12:52 PM
5696 - 5695 - Start charging cycle; Remark:5694
Procedure Step
Published
11/03/2022 10:41 AM
5695 - Start charging cycle
Instruction
Published
11/03/2022 10:40 AM
5694 - The yellow button will start the discharge cycle. There are different charger...
Remark
Published
11/03/2022 10:41 AM
5693 - 5692 - Wait for charging cycle to complete; Remark:5691
Procedure Step
Published
11/03/2022 10:39 AM
5692 - Wait for charging cycle to complete
Instruction
Published
11/03/2022 10:38 AM
5691 - The charger will fully discharge the battery and then fully recharge it. Time...
Remark
Published
11/03/2022 10:39 AM
253 - 242 - Document and report any unresolved problems; Remark:
Procedure Step
Published
06/22/2021 10:23 AM
242 - Document and report any unresolved problems
Instruction
Published
04/21/2025 11:45 AM
Routine Maintenance Procedure
Document Type
Published
03/02/2020 3:31 PM
hours
Duration
Published
05/26/2022 11:45 AM
Semi-annually
Frequency
Published
11/03/2022 2:10 PM
Technician 1
Skill Level
Published
05/14/2020 2:56 PM
None
Tools
Published
05/06/2020 9:50 PM
packeye_di_charger_disconnect_redarrow_00782.jpg
படம்
Published
10/20/2023 12:54 PM
packeye_ui_power_on_00719
படம்
Published
02/07/2022 1:46 AM
packeye_di_charger_connect_redarrow_00783.jpg
படம்
Published
10/20/2023 12:53 PM
packeye_di_batteryCHARGING_0.jpg
படம்
Published
10/23/2023 1:43 PM
packeye_di_batteryREADY.jpg
படம்
Published
10/23/2023 9:34 AM
packeye_di_backupbattery_oncharger.jpg
படம்
Published
10/20/2023 3:50 PM
packeye_di_battery_charger_discharging.jpg
படம்
Published
10/23/2023 9:11 AM
packeye_di_battery_charger_status_LED.jpg
படம்
Published
10/23/2023 9:12 AM

RadSeeker Routine Assessment

Last Updated: 04/24/2025 1:41 AM

The following table lists all the components that make up the document.

Title Type Status Last Updated
Smiths Detection RadSeeker CS
Device
Published
06/27/2024 12:54 PM
247 - 257 - Prepare instrument; Remark:
Procedure Step
Published
04/11/2025 9:08 PM
257 - Prepare instrument
Instruction
Published
04/11/2025 9:07 PM
4713 - 2295 - Verify sufficient battery charge; Remark:2301
Procedure Step
Published
07/01/2022 12:56 AM
2295 - Verify sufficient battery charge
Instruction
Published
04/06/2021 4:43 PM
2301 - Open the battery cover to view the charge level indicator.
Remark
Published
07/23/2021 8:38 PM
4714 - Replace battery pack or charge instrument if fewer than two (2) bars are visi...
Remark
Published
06/29/2022 1:06 PM
4723 - 220 - Power on instrument; Remark:4721
Procedure Step
Published
07/01/2022 1:02 AM
220 - Power on instrument
Instruction
Published
04/06/2025 7:00 PM
4721 - Press and hold ENTER button until display powers on (3 to 5 ...
Remark
Published
06/29/2022 1:12 PM
2298 - IO RadSeeker Button Pad Select Button Yellow Box
Remark
Published
10/21/2024 7:26 PM
4724 - 220 - Power on instrument; Remark:4721
Procedure Step
Published
04/07/2025 12:23 PM
5978 - IO RadSeeker Select Middle
Remark
Published
11/15/2022 11:50 AM
4725 - 315 - Connect charger; Remark:4717
Procedure Step
Published
07/01/2022 12:59 AM
315 - Connect charger
Instruction
Published
07/20/2021 10:45 AM
4717 - Plug charger into instrument and AC [alternating current] power outlet.
Remark
Published
06/29/2022 1:16 PM
4726 - 4716 - Verify instrument is charging; Remark:4715
Procedure Step
Published
12/21/2022 8:31 AM
4716 - Verify instrument is charging
Instruction
Published
06/29/2022 1:16 PM
4715 - IO RadSeeker Power Connected Screen
Remark
Published
06/29/2022 1:18 PM
4778 - 3601 - Connect instrument to computer; Remark:4830
Procedure Step
Published
06/30/2022 4:01 PM
3601 - Connect instrument to computer
Instruction
Published
09/23/2021 5:51 PM
4830 - IO Laptop USB Connection
Remark
Published
07/27/2022 4:23 PM
3608 - IO RadSeeker Insert mini-USB
Remark
Published
09/23/2021 5:59 PM
4670 - 4668 - Verify Configuration; Remark:
Procedure Step
Published
06/23/2022 1:34 PM
4669 - Note : The next steps require HATS version 2.8.
Annotation
Published
06/23/2022 1:34 PM
4668 - Verify Configuration
Instruction
Published
06/23/2022 1:33 PM
4677 - 4676 - Start HATS software; Remark:4862
Procedure Step
Published
06/23/2022 1:43 PM
4676 - Start HATS software
Instruction
Published
06/23/2022 1:42 PM
4862 - IO HATS App Logo
Remark
Published
07/28/2022 12:36 PM
4678 - 4675 - Connect instrument to HATS; Remark:4674
Procedure Step
Published
06/23/2022 1:51 PM
4675 - Connect instrument to HATS
Instruction
Published
06/23/2022 1:45 PM
4674 - Select RadSeeker from the dropdown list. Click on the Connec...
Remark
Published
06/23/2022 1:51 PM
4772 - 4771 - Verify settings are correct; Remark:4770
Procedure Step
Published
06/29/2022 1:24 PM
4771 - Verify settings are correct
Instruction
Published
04/12/2025 11:41 AM
4770 - Navigate to Settings page.
Remark
Published
06/29/2022 1:24 PM
4773 - 4769 - Restore Nuclear Smuggling Detection and Deterrence (NSDD) settings; Remark:4768
Procedure Step
Published
06/29/2022 1:25 PM
4769 - Restore Nuclear Smuggling Detection and Deterrence (NSDD) settings
Instruction
Published
06/29/2022 1:25 PM
4768 - Click Reset to NSDD Defaults.
Remark
Published
06/29/2022 1:25 PM
4774 - 4767 - Set date and time settings; Remark:4766
Procedure Step
Published
06/29/2022 1:27 PM
4767 - Set date and time settings
Instruction
Published
06/29/2022 1:26 PM
4766 - Navigate to Device Utilities page. Select Device Specific ta...
Remark
Published
06/29/2022 11:41 PM
4775 - 4765 - Set password; Remark:4764
Procedure Step
Published
06/29/2022 1:28 PM
4765 - Set password
Instruction
Published
06/29/2022 1:27 PM
4764 - Navigate to Device Utilities page. Select General tab. Selec...
Remark
Published
06/29/2022 11:40 PM
4776 - 4763 - Disable Wi-Fi; Remark:4762
Procedure Step
Published
06/29/2022 1:31 PM
4763 - Disable Wi-Fi
Instruction
Published
06/29/2022 1:29 PM
4762 - Navigate to Device Utilities page. Select Network tab. Click...
Remark
Published
06/29/2022 11:39 PM
4673 - 4672 - Perform a Self-Test; Remark:
Procedure Step
Published
06/23/2022 1:39 PM
4672 - Perform a Self-Test
Instruction
Published
06/23/2022 1:39 PM
4759 - 3525 - Navigate to Menu; Remark:4757
Procedure Step
Published
07/01/2022 1:25 AM
3525 - Navigate to Menu
Instruction
Published
07/29/2021 6:41 AM
4757 - Press DOWN to select Menu.
Remark
Published
06/29/2022 1:33 PM
4760 - 4755 - Select Self-test; Remark:4754
Procedure Step
Published
06/29/2022 1:37 PM
4755 - Select Self-test
Instruction
Published
06/29/2022 1:35 PM
4754 - Use UP and DOWN to select Self-test and press ENTER
Remark
Published
06/29/2022 1:36 PM
4761 - 4753 - Respond to self-test; Remark:4752
Procedure Step
Published
06/29/2022 1:39 PM
4756 - Note : Failures during the self-test are most likely a result of cables not properly...
Annotation
Published
06/29/2022 1:37 PM
4753 - Respond to self-test
Instruction
Published
06/29/2022 1:38 PM
4752 - Answer the question prompts on the RadSeeker regarding instrument feedback su...
Remark
Published
06/29/2022 1:39 PM
4710 - 319 - Perform operational test; Remark:4863
Procedure Step
Published
06/30/2022 3:37 PM
319 - Perform operational test
Instruction
Published
06/10/2021 8:31 PM
4863 - Perform DET-HHD-SMD-RM01 RadSeeker Operational Test.
Remark
Published
07/28/2022 1:43 PM
4708 - 4707 - Perform HATS Assessment; Remark:
Procedure Step
Published
06/29/2022 9:50 AM
4707 - Perform HATS Assessment
Instruction
Published
06/29/2022 9:48 AM
4740 - 4739 - Navigate to Assessments page; Remark:4861
Procedure Step
Published
06/29/2022 1:46 PM
4739 - Navigate to Assessments page
Instruction
Published
06/29/2022 1:40 PM
4861 - IO HATS Navigate to Assessments
Remark
Published
07/28/2022 12:51 PM
4751 - 4748 - Document preliminary assessment results; Remark:4747
Procedure Step
Published
07/28/2022 1:01 PM
4748 - Document preliminary assessment results
Instruction
Published
06/29/2022 1:44 PM
4747 - Select Maintenance. Type "Routine Annual Assessment" in
Remark
Published
06/29/2022 11:38 PM
4741 - 4738 - Perform assessment; Remark:4737
Procedure Step
Published
06/29/2022 1:47 PM
4738 - Perform assessment
Instruction
Published
06/29/2022 1:47 PM
4737 - Click Perform Assessment. Select Result tab...
Remark
Published
06/29/2022 11:33 PM
4742 - 4736 - Save assessment file; Remark:4735
Procedure Step
Published
06/29/2022 1:49 PM
4736 - Save assessment file
Instruction
Published
06/29/2022 1:48 PM
4735 - IO HATS Export Package Save
Remark
Published
06/29/2022 1:49 PM
4743 - 4734 - Disconnect instrument from HATS; Remark:4733
Procedure Step
Published
07/27/2022 4:03 PM
4734 - Disconnect instrument from HATS
Instruction
Published
06/29/2022 1:50 PM
4733 - IO RadSeeker Disconnect from HATS
Remark
Published
06/29/2022 1:51 PM
4744 - 4734 - Disconnect instrument from HATS; Remark:5977
Procedure Step
Published
07/01/2022 1:21 AM
5977 - IO RadSeeker Disconnect from HATS Red Box
Remark
Published
11/15/2022 11:51 AM
4745 - 220 - Power on instrument; Remark:4729
Procedure Step
Published
07/01/2022 1:22 AM
4729 - Press and hold ENTER button until display powers on (3 to 5 ...
Remark
Published
06/29/2022 1:56 PM
4746 - 4728 - Verify instrument successfully completes startup; Remark:2306
Procedure Step
Published
06/29/2022 1:58 PM
4728 - Verify instrument successfully completes startup
Instruction
Published
06/29/2022 1:57 PM
2306 - The instrument will automatically enter Detect mode after sy...
Remark
Published
07/23/2021 8:45 PM
4706 - 4705 - Submit report; Remark:4864
Procedure Step
Published
06/29/2022 9:50 AM
4705 - Submit report
Instruction
Published
06/29/2022 9:50 AM
4864 - As specified by management or contractual obligations.
Remark
Published
07/28/2022 1:36 PM
Routine Maintenance Procedure
Document Type
Published
03/02/2020 3:31 PM
minutes
Duration
Published
05/26/2022 11:41 AM
Annually
Frequency
Published
04/01/2020 11:37 AM
Note
Annotation Type
Published
03/02/2020 3:25 PM
Technician 2
Skill Level
Published
04/09/2020 1:17 AM
None
Tools
Published
05/06/2020 9:50 PM
radseeker_di_battopen_2arrow_00659.jpg
படம்
Published
10/20/2023 9:31 AM
radseeker_di_battbar_000477.jpg
படம்
Published
10/18/2023 4:32 PM
radseeker_di_selectmiddle_00473.jpg
படம்
Published
10/20/2023 9:35 AM
radseeker_di_chargerconnect2_redarrow.jpg
படம்
Published
10/20/2023 10:30 AM
radseeker_ui_chargingplug_183cps.jpg
படம்
Published
10/20/2023 10:29 AM
Laptop USB Plug-in
படம்
Published
12/24/2021 1:50 AM
RadSeeker Connector USB Insert
படம்
Published
12/24/2021 1:50 AM
HATS App Logo
படம்
Published
07/28/2022 11:52 AM
radseeker_ui_HATSconnectlist.jpg
படம்
Published
10/20/2023 10:31 AM
radseeker_ui_HATSsettingsnav_redbox.jpg
படம்
Published
10/20/2023 10:31 AM
HATS Reset to NSDD Defaults
படம்
Published
07/28/2022 12:01 PM
HATS Set Date and Time
படம்
Published
07/28/2022 12:03 PM
HATS Reset Password
படம்
Published
07/28/2022 12:05 PM
HATS Disable WiFi Utility
படம்
Published
07/28/2022 12:08 PM
radseeker_ui_menu_right_button.jpg
படம்
Published
10/20/2023 10:32 AM
radseeker_ui_menu_selftest_61cps.jpg
படம்
Published
10/20/2023 10:33 AM
HATS Assessment Menu Clipboard Icon
படம்
Published
07/28/2022 12:16 PM
HATS Assessment reason maintenance
படம்
Published
07/28/2022 12:20 PM
HATS Assessment Perform Button and Results
படம்
Published
07/28/2022 12:23 PM
HATS Export Package Button
படம்
Published
07/28/2022 12:24 PM
radseeker_ui_HATSdisconnect_0.jpg
படம்
Published
10/20/2023 10:28 AM
radseeker_ui_modedetect_217cps_00467.jpg
படம்
Published
10/20/2023 10:15 AM

RS-350 Operational Test

Last Updated: 04/24/2025 1:41 AM

The following table lists all the components that make up the document.

Title Type Status Last Updated
Radiation Solutions Inc. RS-350
Device
Published
10/20/2024 8:53 AM
4819 - 257 - Prepare instrument; Remark:
Procedure Step
Published
07/27/2022 1:18 PM
1468 - Note : No artificial radioactive sources should be present during the initial startu...
Annotation
Published
07/27/2022 1:16 PM
257 - Prepare instrument
Instruction
Published
04/11/2025 9:07 PM
786 - 219 - Verify there are no sources of radiation near instrument; Remark:7
Procedure Step
Published
04/20/2025 6:37 PM
219 - Verify there are no sources of radiation near instrument
Instruction
Published
04/12/2025 4:20 PM
7 - No Radiation symbol
Remark
Published
07/12/2021 1:34 PM
4424 - 220 - Power on instrument; Remark:4423
Procedure Step
Published
06/10/2022 6:25 AM
220 - Power on instrument
Instruction
Published
04/06/2025 7:00 PM
4423 - Open backpack and press power button for approximately 1 second.
Remark
Published
06/10/2022 5:14 AM
1496 - 1495 - Power on mobile device; Remark:
Procedure Step
Published
11/12/2020 4:40 PM
1495 - Power on mobile device
Instruction
Published
11/12/2020 4:20 PM
4425 - 4421 - Open RadMobile app; Remark:4811
Procedure Step
Published
06/10/2022 5:16 AM
4422 - Note : Refer to DET-HHD-RSI-RS3-OP02, RS-350 RadMobile App Pairing for app ...
Annotation
Published
06/10/2022 5:16 AM
4421 - Open RadMobile app
Instruction
Published
06/10/2022 5:15 AM
4811 - IO RS350 RadMobile App Logo No Words
Remark
Published
07/07/2022 12:54 PM
4426 - 4420 - Select name of RS-350; Remark:4419
Procedure Step
Published
06/10/2022 5:17 AM
4420 - Select name of RS-350
Instruction
Published
06/10/2022 5:17 AM
4419 - The last connected device will appear as the first option on the screen. ...
Remark
Published
06/10/2022 5:17 AM
4427 - 1432 - Verify backpack connection to mobile device; Remark:4418
Procedure Step
Published
06/10/2022 5:20 AM
1432 - Verify backpack connection to mobile device
Instruction
Published
09/01/2020 7:34 PM
4418 - Gamma and neutron values will be changing.
Remark
Published
06/10/2022 5:20 AM
4428 - 2295 - Verify sufficient battery charge; Remark:4416
Procedure Step
Published
06/10/2022 5:23 AM
2295 - Verify sufficient battery charge
Instruction
Published
04/06/2021 4:43 PM
4416 - Backpack battery life is indicated by the battery icon in the app.
Remark
Published
06/10/2022 5:22 AM
4417 - Mobile device battery life is typically indicated at the top of the display.
Remark
Published
06/10/2022 5:23 AM
252 - 232 - Check instrument gamma response; Remark:
Procedure Step
Published
07/29/2021 11:10 AM
232 - Check instrument gamma response
Instruction
Published
07/23/2021 9:58 AM
4497 - 235 - Place instrument next to radioactive gamma source; Remark:4817
Procedure Step
Published
06/10/2022 7:59 AM
235 - Place instrument next to radioactive gamma source
Instruction
Published
07/09/2021 1:39 PM
4817 - IO RS350 Move Closer to Rad Source Trefoil
Remark
Published
07/07/2022 7:25 PM
4498 - 1439 - Verify instrument responds to radioactive source; Remark:4495
Procedure Step
Published
06/10/2022 8:00 AM
1439 - Verify instrument responds to radioactive source
Instruction
Published
06/29/2022 11:50 PM
4495 - Gamma dose rate and count rate values will increase. Movin...
Remark
Published
07/07/2022 7:21 PM
4496 - Automatic identification of the radiation source may occur as the RS-350 is b...
Remark
Published
07/07/2022 7:23 PM
2251 - 2217 - Perform Identification Measurement; Remark:
Procedure Step
Published
07/28/2021 9:55 PM
2217 - Perform Identification Measurement
Instruction
Published
04/06/2021 5:13 PM
4452 - 859 - Start identification measurement; Remark:4430
Procedure Step
Published
06/10/2022 6:07 AM
859 - Start identification measurement
Instruction
Published
10/26/2020 7:00 PM
4430 - Tap menu icon.
Remark
Published
06/10/2022 5:38 AM
4451 - Tap Start dwell.
Remark
Published
06/10/2022 6:07 AM
4453 - 2220 - Wait for measurement to complete; Remark:4809
Procedure Step
Published
04/20/2025 12:56 PM
2220 - Wait for measurement to complete
Instruction
Published
10/22/2020 11:15 AM
4809 - IO RS350 Dwell Mode Timer Running 3/60
Remark
Published
07/06/2022 4:29 PM
4492 - 1442 - Verify identification results are correct; Remark:4491
Procedure Step
Published
06/10/2022 7:28 AM
1442 - Verify identification results are correct
Instruction
Published
09/02/2020 3:03 PM
4491 - Identification results should match the isotopes associated with the radioact...
Remark
Published
07/07/2022 7:19 PM
4493 - 4490 - Tap CLOSE; Remark:4489
Procedure Step
Published
06/10/2022 7:29 AM
4490 - Tap CLOSE
Instruction
Published
06/10/2022 7:29 AM
4489 - This will return the instrument to Automatic mode.
Remark
Published
07/07/2022 7:18 PM
4494 - 4488 - Move instrument away from radioactive gamma source; Remark:4818
Procedure Step
Published
06/10/2022 7:30 AM
4488 - Move instrument away from radioactive gamma source
Instruction
Published
06/10/2022 7:30 AM
4818 - IO RS350 Move Away from Rad Source Trefoil
Remark
Published
07/07/2022 7:26 PM
4481 - 4480 - Check instrument neutron response (if available); Remark:
Procedure Step
Published
06/10/2022 7:19 AM
4480 - Check instrument neutron response (if available)
Instruction
Published
06/10/2022 7:19 AM
4485 - 3095 - Place instrument next to radioactive neutron source; Remark:4817
Procedure Step
Published
06/10/2022 7:31 AM
3095 - Place instrument next to radioactive neutron source
Instruction
Published
07/16/2021 10:49 AM
4486 - 1439 - Verify instrument responds to radioactive source; Remark:4484
Procedure Step
Published
06/10/2022 7:32 AM
4484 - Neutron count rate values will increase. The mobile device...
Remark
Published
07/07/2022 7:17 PM
4487 - 4483 - Move instrument away from radioactive neutron source; Remark:4818
Procedure Step
Published
06/10/2022 7:33 AM
4483 - Move instrument away from radioactive neutron source
Instruction
Published
06/10/2022 7:33 AM
253 - 242 - Document and report any unresolved problems; Remark:
Procedure Step
Published
06/22/2021 10:23 AM
242 - Document and report any unresolved problems
Instruction
Published
04/21/2025 11:45 AM
Routine Maintenance Procedure
Document Type
Published
03/02/2020 3:31 PM
minutes
Duration
Published
05/26/2022 11:41 AM
Annually
Frequency
Published
04/01/2020 11:37 AM
Before each use
Frequency
Published
08/31/2020 5:00 PM
Monthly
Frequency
Published
04/01/2020 11:36 AM
Note
Annotation Type
Published
03/02/2020 3:25 PM
Technician 1
Skill Level
Published
05/14/2020 2:56 PM
None
Tools
Published
05/06/2020 9:50 PM
No Radiation Symbol
படம்
Published
08/13/2024 2:56 PM
RS350 Power Button Green Light
படம்
Published
07/05/2022 3:50 PM
RS-350 RadMobile App Logo
படம்
Published
07/05/2022 4:34 PM
RS-350 App Connecting Serial Number Full Screen
படம்
Published
07/06/2022 1:18 PM
RS-350 Graph 70.5 nSv Boxes Dose, Counts, Graph
படம்
Published
07/05/2022 4:18 PM
RS-350 App Battery Icon Red Box
படம்
Published
07/06/2022 1:09 PM
RS-350 App Mobile Battery Percent
படம்
Published
07/06/2022 1:37 PM
RS-350 Move to Rad Source
படம்
Published
07/05/2022 3:56 PM
RS-350 Graph Alarm Response Red Arrow
படம்
Published
07/05/2022 4:22 PM
RS-350 Identification Dwell Result Co-60
படம்
Published
07/05/2022 5:35 PM
RS-350 App Menu Icon Red Box
படம்
Published
07/06/2022 1:27 PM
RS-350 Identification Dwell Start
படம்
Published
07/05/2022 5:37 PM
RS-350 Wait Dwell 3 of 60 sec
படம்
Published
07/05/2022 4:05 PM
RS-350 Close Dwell Mode
படம்
Published
07/05/2022 5:32 PM
RS-350 Move away from Rad Source
படம்
Published
07/05/2022 3:58 PM
RS-350 Alarm Neutron Red Box 10 CPS
படம்
Published
07/05/2022 5:20 PM

Handheld Radiation Monitor Routine Assessment

Last Updated: 04/24/2025 1:40 AM

The following table lists all the components that make up the document.

Title Type Status Last Updated
Sensor Tech Handheld Radiation Monitor
Device
Published
10/28/2024 3:52 PM
4384 - 4383 - Document serial number; Remark:4382
Procedure Step
Published
06/06/2022 9:39 PM
4383 - Document serial number
Instruction
Published
06/06/2022 9:38 PM
4382 - Record information on the Handheld Radiation Monitor Assessment Form...
Remark
Published
06/06/2022 9:38 PM
4381 - 319 - Perform operational test; Remark:4380
Procedure Step
Published
06/06/2022 9:40 PM
319 - Perform operational test
Instruction
Published
06/10/2021 8:31 PM
4380 - DET-HHD-STE-HRM-RM01, Handheld Radiation Monitor Operational Test.
Remark
Published
06/06/2022 9:40 PM
4379 - 4378 - Replace battery; Remark:4377
Procedure Step
Published
06/06/2022 9:42 PM
4378 - Replace battery
Instruction
Published
06/06/2022 9:41 PM
4377 - DET-HHD-STE-HRM-RM02, Handheld Radiation Monitor Battery Replacement...
Remark
Published
06/06/2022 9:42 PM
4376 - 346 - Submit assessment form; Remark:4375
Procedure Step
Published
06/06/2022 9:43 PM
346 - Submit assessment form
Instruction
Published
06/16/2021 10:39 PM
4375 - Submit Handheld Radiation Monitor Assessment Form or HATS [Handheld ...
Remark
Published
06/06/2022 9:43 PM
Routine Maintenance Procedure
Document Type
Published
03/02/2020 3:31 PM
minutes
Duration
Published
05/26/2022 11:41 AM
Annually
Frequency
Published
04/01/2020 11:37 AM
Technician 1
Skill Level
Published
05/14/2020 2:56 PM
None
Tools
Published
05/06/2020 9:50 PM
HRM Serial Number Location
படம்
Published
08/02/2022 7:55 PM
HRM Assessment Form for RM03
File
Published
08/03/2022 10:47 AM

Handheld Radiation Monitor Operational Test

Last Updated: 04/24/2025 1:40 AM

The following table lists all the components that make up the document.

Title Type Status Last Updated
Sensor Tech Handheld Radiation Monitor
Device
Published
10/28/2024 3:52 PM
247 - 257 - Prepare instrument; Remark:
Procedure Step
Published
04/11/2025 9:08 PM
257 - Prepare instrument
Instruction
Published
04/11/2025 9:07 PM
786 - 219 - Verify there are no sources of radiation near instrument; Remark:7
Procedure Step
Published
04/20/2025 6:37 PM
219 - Verify there are no sources of radiation near instrument
Instruction
Published
04/12/2025 4:20 PM
7 - No Radiation symbol
Remark
Published
07/12/2021 1:34 PM
4316 - 220 - Power on instrument; Remark:4315
Procedure Step
Published
06/06/2022 5:58 PM
220 - Power on instrument
Instruction
Published
04/06/2025 7:00 PM
4315 - Set instrument to AUDIO mode.
Remark
Published
06/06/2022 5:58 PM
4290 - 612 - Wait for instrument to complete start-up sequence; Remark:4286
Procedure Step
Published
04/13/2025 6:50 PM
612 - Wait for instrument to complete start-up sequence
Instruction
Published
04/13/2025 6:38 PM
4286 - The unit is ready for operation when the period flashes every 20 seconds....
Remark
Published
06/06/2022 4:11 PM
252 - 232 - Check instrument gamma response; Remark:
Procedure Step
Published
07/29/2021 11:10 AM
232 - Check instrument gamma response
Instruction
Published
07/23/2021 9:58 AM
4312 - 235 - Place instrument next to radioactive gamma source; Remark:4884
Procedure Step
Published
06/06/2022 6:00 PM
235 - Place instrument next to radioactive gamma source
Instruction
Published
07/09/2021 1:39 PM
4884 - IO HRM Move Closer to Rad Source
Remark
Published
08/04/2022 1:44 PM
4313 - 2936 - Verify audible alarm functions correctly; Remark:4310
Procedure Step
Published
06/06/2022 6:02 PM
2936 - Verify audible alarm functions correctly
Instruction
Published
06/15/2021 4:09 PM
4310 - The instrument should respond as follows: Instrument will e...
Remark
Published
06/06/2022 6:01 PM
4311 - Numeric value will appear in the gamma LED [light-emitting diode] dis...
Remark
Published
06/06/2022 6:02 PM
4314 - 241 - Move instrument away from radioactive gamma source; Remark:4883
Procedure Step
Published
06/06/2022 6:03 PM
241 - Move instrument away from radioactive gamma source
Instruction
Published
06/25/2021 12:22 PM
4883 - IO HRM Move Away from Rad Source
Remark
Published
08/04/2022 1:47 PM
2914 - 2912 - Test vibration alarm; Remark:
Procedure Step
Published
06/06/2022 5:28 PM
2912 - Test vibration alarm
Instruction
Published
06/15/2021 4:11 PM
4320 - 4319 - Change to VIBRATE mode; Remark:4318
Procedure Step
Published
06/06/2022 6:08 PM
4319 - Change to VIBRATE mode
Instruction
Published
06/06/2022 6:07 PM
4318 - Quickly move switch to VIBRATE.
Remark
Published
06/06/2022 6:08 PM
4323 - 2938 - Verify vibration alarm functions correctly; Remark:4321
Procedure Step
Published
06/06/2022 6:12 PM
2938 - Verify vibration alarm functions correctly
Instruction
Published
06/15/2021 4:12 PM
4321 - The instrument should respond as follows: Instrument will v...
Remark
Published
06/06/2022 6:11 PM
4322 - Numeric value will appear in the gamma LED display.
Remark
Published
06/06/2022 6:11 PM
4329 - 4328 - Check response with neutron radioactive source; Remark:
Procedure Step
Published
06/06/2022 6:21 PM
4332 - Note : The neutron response can be performed using a neutron radioactive source or b...
Annotation
Published
06/06/2022 6:37 PM
4328 - Check response with neutron radioactive source
Instruction
Published
06/06/2022 6:21 PM
4326 - 3095 - Place instrument next to radioactive neutron source; Remark:4884
Procedure Step
Published
06/06/2022 6:31 PM
3095 - Place instrument next to radioactive neutron source
Instruction
Published
07/16/2021 10:49 AM
4325 - 3097 - Verify instrument responds correctly; Remark:4310
Procedure Step
Published
06/06/2022 6:24 PM
3096 - Note : Most radioactive neutron sources also have a gamma component, which will likely ...
Annotation
Published
07/23/2021 9:57 AM
3097 - Verify instrument responds correctly
Instruction
Published
07/16/2021 10:50 AM
4324 - Numeric value will appear in the neutron LED display. Blue...
Remark
Published
06/06/2022 6:24 PM
4327 - 3098 - Move instrument away from radioactive neutron source; Remark:4883
Procedure Step
Published
06/06/2022 6:32 PM
3098 - Move instrument away from radioactive neutron source
Instruction
Published
07/16/2021 10:54 AM
4338 - 3095 - Place instrument next to radioactive neutron source; Remark:4884
Procedure Step
Published
06/06/2022 6:31 PM
4331 - 3097 - Verify instrument responds correctly; Remark:4321
Procedure Step
Published
06/06/2022 6:51 PM
4330 - Numeric value will appear in the neutron LED display. Blue...
Remark
Published
06/06/2022 6:51 PM
4339 - 3098 - Move instrument away from radioactive neutron source; Remark:4883
Procedure Step
Published
06/06/2022 6:32 PM
4337 - 4335 - Check response with background neutron radiation; Remark:
Procedure Step
Published
06/06/2022 7:01 PM
4336 - Note : If no neutron radioactive source is available, the following step can be used...
Annotation
Published
06/06/2022 7:01 PM
4335 - Check response with background neutron radiation
Instruction
Published
06/06/2022 7:01 PM
4344 - 4343 - Monitor neutron LED; Remark:4342
Procedure Step
Published
06/06/2022 7:11 PM
4343 - Monitor neutron LED
Instruction
Published
06/06/2022 7:10 PM
4342 - Watch neutron LED carefully in a low-light environment for at least 5 minutes...
Remark
Published
06/06/2022 7:11 PM
4345 - 4341 - Verify instrument responds to background neutron radiation; Remark:4340
Procedure Step
Published
06/06/2022 7:13 PM
4341 - Verify instrument responds to background neutron radiation
Instruction
Published
06/06/2022 7:11 PM
4340 - In natural background, the instrument should respond about one (1) to three (...
Remark
Published
06/06/2022 7:13 PM
4349 - 4343 - Monitor neutron LED; Remark:4342
Procedure Step
Published
06/06/2022 7:11 PM
4350 - 4341 - Verify instrument responds to background neutron radiation; Remark:4348
Procedure Step
Published
06/06/2022 7:17 PM
4348 - In natural background, the instrument should respond about one (1) to three (...
Remark
Published
06/06/2022 7:16 PM
253 - 242 - Document and report any unresolved problems; Remark:
Procedure Step
Published
06/22/2021 10:23 AM
242 - Document and report any unresolved problems
Instruction
Published
04/21/2025 11:45 AM
Routine Maintenance Procedure
Document Type
Published
03/02/2020 3:31 PM
minutes
Duration
Published
05/26/2022 11:41 AM
Before each use
Frequency
Published
08/31/2020 5:00 PM
Daily
Frequency
Published
04/01/2020 11:36 AM
Note
Annotation Type
Published
03/02/2020 3:25 PM
Technician 1
Skill Level
Published
05/14/2020 2:56 PM
None
Tools
Published
05/06/2020 9:50 PM
No Radiation Symbol
படம்
Published
08/13/2024 2:56 PM
HRM Switch in AUDIO position
படம்
Published
08/02/2022 5:03 PM
HRM Red LED Dot Period
படம்
Published
08/02/2022 4:53 PM
HRM Move to Rad Source Trefoil
படம்
Published
08/02/2022 7:57 PM
HRM Alert Audio
படம்
Published
08/02/2022 7:51 PM
HRM Red LED Display 3
படம்
Published
08/02/2022 7:47 PM
HRM Move away from Rad Source Trefoil
படம்
Published
08/02/2022 7:59 PM
HRM Switch in VIBRATE position
படம்
Published
08/02/2022 5:06 PM
HRM Alert Vibrate
படம்
Published
08/02/2022 7:52 PM
HRM Alert Audio Neutron Full Size
படம்
Published
08/04/2022 4:58 PM
HRM Alert Blue LED Neutron Level 3
படம்
Published
08/03/2022 10:29 AM
HRM Alert Vibrate Neutron Full Size
படம்
Published
08/04/2022 5:00 PM
HRM Alert Audio Neutron
படம்
Published
08/03/2022 10:32 AM
HRM Alert Vibrate Neutron
படம்
Published
08/03/2022 10:34 AM

PackEye Backup Battery

Last Updated: 04/24/2025 1:40 AM

The following table lists all the components that make up the document.

Title Type Status Last Updated
Thermo FHT1377 PackEye
Device
Published
10/28/2024 3:37 PM
4193 - 4192 - Charge backup battery; Remark:4207
Procedure Step
Published
05/10/2022 1:42 PM
4192 - Charge backup battery
Instruction
Published
05/10/2022 1:42 PM
4207 - The backup battery and charger are included in the PackEye accessory case. Ba...
Remark
Published
05/10/2022 1:50 PM
4203 - 4202 - Disconnect Primary Battery; Remark:
Procedure Step
Published
05/10/2022 1:44 PM
4202 - Disconnect Primary Battery
Instruction
Published
05/10/2022 1:44 PM
3869 - 313 - Power off instrument; Remark:3850
Procedure Step
Published
03/29/2022 2:23 AM
313 - Power off instrument
Instruction
Published
07/23/2021 2:41 PM
3850 - Press and hold the power button for approximately 10 seconds until indicator ...
Remark
Published
03/29/2022 1:38 AM
4223 - 4222 - Place instrument on flat surface; Remark:4221
Procedure Step
Published
05/10/2022 1:56 PM
4222 - Place instrument on flat surface
Instruction
Published
05/10/2022 1:54 PM
4221 - Shoulder straps should be facing down.
Remark
Published
05/10/2022 1:55 PM
3926 - 3876 - Open top of backpack; Remark:3928
Procedure Step
Published
04/05/2022 5:28 PM
3876 - Open top of backpack
Instruction
Published
04/04/2022 3:14 PM
3928 - IO PackEye Open Top of Backpack for Battery Access
Remark
Published
10/24/2024 6:52 PM
4224 - 4219 - Remove distribution box; Remark:4218
Procedure Step
Published
05/10/2022 1:59 PM
4220 - Note : The distribution box is usually in the top of the backpack. On some models, i...
Annotation
Published
05/10/2022 1:59 PM
4219 - Remove distribution box
Instruction
Published
05/10/2022 1:58 PM
4218 - The distribution box is usually located in the top of the backpack.
Remark
Published
05/10/2022 1:58 PM
4225 - 4217 - Disconnect battery cable; Remark:4216
Procedure Step
Published
05/10/2022 2:03 PM
4217 - Disconnect battery cable
Instruction
Published
05/10/2022 2:01 PM
4216 - Rotate the collar counterclockwise and pull straight out. The battery cable c...
Remark
Published
05/10/2022 2:03 PM
4201 - 4200 - Connect Spare Battery; Remark:
Procedure Step
Published
05/10/2022 1:45 PM
4200 - Connect Spare Battery
Instruction
Published
05/10/2022 1:45 PM
4232 - 4231 - Connect backup battery to adapter cable; Remark:4230
Procedure Step
Published
05/17/2022 10:09 AM
4249 - Note : Backup battery should be charged prior to installation.
Annotation
Published
05/17/2022 10:06 AM
4231 - Connect backup battery to adapter cable
Instruction
Published
05/10/2022 2:08 PM
4230 - The adapter cable is included in the PackEye accessory case. The cable might ...
Remark
Published
05/10/2022 2:10 PM
4233 - 4228 - Connect adapter cable to distribution box; Remark:4227
Procedure Step
Published
05/10/2022 2:13 PM
4229 - Caution : Align connectors first. Do not use excessive force to push connectors togethe...
Annotation
Published
05/10/2022 2:13 PM
4228 - Connect adapter cable to distribution box
Instruction
Published
05/10/2022 2:11 PM
4227 - Align connectors. Push connectors together. Rotate collar clockwise.
Remark
Published
05/10/2022 2:12 PM
4199 - 4198 - Repack Instrument; Remark:
Procedure Step
Published
05/10/2022 1:46 PM
4198 - Repack Instrument
Instruction
Published
05/10/2022 1:46 PM
4238 - 4237 - Replace distribution box; Remark:4236
Procedure Step
Published
05/10/2022 2:17 PM
4237 - Replace distribution box
Instruction
Published
05/10/2022 2:15 PM
4236 - IO PackEye Distro Box Install
Remark
Published
10/24/2024 6:53 PM
4239 - 4235 - Place backup battery in top pocket of backpack; Remark:4234
Procedure Step
Published
05/10/2022 2:19 PM
4235 - Place backup battery in top pocket of backpack
Instruction
Published
05/10/2022 2:18 PM
4234 - IO PackEye Backup Battery in Pocket
Remark
Published
10/24/2024 6:54 PM
4240 - 1383 - Close backpack; Remark:
Procedure Step
Published
05/10/2022 2:21 PM
1383 - Close backpack
Instruction
Published
11/19/2020 5:23 PM
3852 - 220 - Power on instrument; Remark:3836
Procedure Step
Published
03/29/2022 1:59 AM
220 - Power on instrument
Instruction
Published
04/06/2025 7:00 PM
3836 - Press power button on the indicator unit for approximately 1 second.
Remark
Published
03/29/2022 1:05 AM
Operator Procedure
Document Type
Published
03/02/2020 3:31 PM
minutes
Duration
Published
05/26/2022 11:41 AM
As Needed
Frequency
Published
04/01/2020 11:36 AM
Note
Annotation Type
Published
03/02/2020 3:25 PM
Caution
Annotation Type
Published
03/02/2020 3:24 PM
Technician 1
Skill Level
Published
05/14/2020 2:56 PM
None
Tools
Published
05/06/2020 9:50 PM
packeye_di_backupbattery_oncharger.jpg
படம்
Published
10/20/2023 3:50 PM
packeye_di_ansmanncharger.jpg
படம்
Published
10/20/2023 3:47 PM
Power off Packeye
படம்
Published
02/19/2022 1:48 AM
packeye_di_opentop_redarrow_00758.jpg
படம்
Published
10/20/2023 12:55 PM
packeye_di_distrobox_remove.jpg
படம்
Published
10/20/2023 4:00 PM
packeye_di_batterycable_remove.jpg
படம்
Published
10/20/2023 3:54 PM
packeye_di_batterycable_2prong.jpg
படம்
Published
10/20/2023 3:51 PM
packeye_di_batterycable_adapter.jpg
படம்
Published
10/20/2023 3:52 PM
packeye_di_backupbattery_connect_adapter.jpg
படம்
Published
10/20/2023 3:49 PM
packeye_di_batterycable_install.jpg
படம்
Published
10/20/2023 3:53 PM
packeye_di_distrobox_install.jpg
படம்
Published
10/20/2023 3:59 PM
packeye_di_backupbattery_pocket.jpg
படம்
Published
10/20/2023 3:50 PM
packeye_ui_power_on_00719
படம்
Published