ID Title Content type Referenced in Step Referenced in Document Published
9326 9326 - 9308 - Insert tamper switch wire into terminal end and crimp using crimping tool; Remark:9522 Procedure Step
9327 9327 - 9309 - Connect tamper switch to existing wiring using terminal end connectors; Remark:9521 Procedure Step
9328 9328 - 9242 - Tamper Switch Replacement and Wiring Connection; Remark: Procedure Step
9329 9329 - 9238 - Measure distance from inside edge of cabinet to edge of tamper switch; Remark:9296 Procedure Step
9330 9330 - 9239 - Measure distance from inside edge of door to edge of magnet; Remark:9297 Procedure Step
9331 9331 - 9240 - Verify alignment of tamper switch and magnet; Remark:9298 Procedure Step
9332 9332 - 9241 - Relocate tamper switch or magnet to correct any misalignment, if necessary; Remark:9299 Procedure Step
9333 9333 - 9237 - Verify Alignment of Tamper Switch and Magnet; Remark: Procedure Step
9334 9334 - 7592 - Inform system operators upon arrival; Remark: Procedure Step
9335 9335 - 7676 - Brief system operators on expected work, duration, anticipated alarms, and fa...; Remark: Procedure Step
9336 9336 - 7967 - Close lane and set up barriers or establish a safety watch; Remark:7595 Procedure Step
9337 9337 - 9235 - Open Control pillar RPM door; Remark: Procedure Step
9338 9338 - 9236 - Switch LD-260 to OFF position and verify green “PWR ON” LED is not lit; Remark:9525 Procedure Step
9339 9339 - 1401 - Establish Initial Conditions; Remark: Procedure Step
9341 9341 - Note : If only replacing the fault LED bulb, twist connector one-quarter turn counte... Annotation 9418 - 1401 - Establish Initial Conditions; Remark: STEP: 9418 - 1401 - Establish Initial Conditions; Remark:
RPM LED Fault Light Assembly Replacement
9342 9342 - For train monitors - open the control cabinet. Remark
9343 9343 - Use a medium Phillips screwdriver for the front of the door and a 7 mm nut dr... Remark 9401 - 9359 - Install new fault light housing to front of door; Remark:9343 STEP: 9401 - 9359 - Install new fault light housing to front of door; Remark:9343
RPM LED Fault Light Assembly Replacement
9344 9344 - Use a medium Phillips screwdriver for the front of the door and a 7 mm nut dr... Remark 9396 - 9365 - Install new fault light housing to front of door; Remark:9344 STEP: 9396 - 9365 - Install new fault light housing to front of door; Remark:9344
RPM LED Fault Light Assembly Replacement
9345 9345 - Join the related wires back together with union connectors. Connect red and w... Remark 9393 - 9375 - Crimp union connectors to appropriate wires using a crimping tool; Remark:9345 STEP: 9393 - 9375 - Crimp union connectors to appropriate wires using a crimping tool; Remark:9345
RPM LED Fault Light Assembly Replacement
9346 9346 - During the Power-On-Self-Test (POST), the lights and audio will operate for a... Remark 9384 - 9377 - Switch LD-260 to on position while watching new LED fault light; Remark:9346
9347 9347 - DET-RPM-RAP-RM03 RPM Operational Test. Remark 9385 - 319 - Perform operational test; Remark:9347
9929 - 319 - Perform operational test; Remark:9347
STEP: 9385 - 319 - Perform operational test; Remark:9347
RPM LD-260 Load Disconnect Replacement
RPM Ethernet-to-Fiber Media Converter Replacement
RPM SCA-774 Single Channel Analyzer Board Replacement
RPM SCA-775 Module Replacement
RPM LD-260 Load Disconnect Fuse Replacement
RPM SC-771 Controller Board Replacement
RPM SC-770 Controller Module Replacement
RPM Banner IR Occupancy Sensor Replacement
RPM Nano Controller Replacement
RPM SPY-2 to IXIO-DT1 Occupancy Sensor Conversion
RPM Neutron Signal Pick-Off Box (PMFX) Replacement
RPM VD-580 Replacement
RPM LED Fault Light Assembly Replacement

STEP: 9929 - 319 - Perform operational test; Remark:9347
RPM AM-270 Remote Alarm Panel Replacement
9348 9348 - Open Control pillar radiation portal monitor (RPM) door Instruction 9416 - 9348 - Open Control pillar radiation portal monitor (RPM) door; Remark:
9350 9350 - Disconnect LED Fault Light Wiring Instruction 9412 - 9350 - Disconnect LED Fault Light Wiring; Remark: STEP: 9412 - 9350 - Disconnect LED Fault Light Wiring; Remark:
RPM LED Fault Light Assembly Replacement
9351 9351 - Open Control door to access terminal block (TB4) on the back of the door ... Instruction 9406 - 9351 - Open Control door to access terminal block (TB4) on the back of the door ...; Remark:8674 STEP: 9406 - 9351 - Open Control door to access terminal block (TB4) on the back of the door ...; Remark:8674
RPM LED Fault Light Assembly Replacement
9352 9352 - Remove black wire (TB4-3) and black wire (TB4-4) from TB4 using a small flath... Instruction 9407 - 9352 - Remove black wire (TB4-3) and black wire (TB4-4) from TB4 using a small flath...; Remark:9530 STEP: 9407 - 9352 - Remove black wire (TB4-3) and black wire (TB4-4) from TB4 using a small flath...; Remark:9530
RPM LED Fault Light Assembly Replacement
9353 9353 - Remove any wire ties securing red and black wires using side cutter pliers Instruction 9408 - 9353 - Remove any wire ties securing red and black wires using side cutter pliers; Remark: STEP: 9408 - 9353 - Remove any wire ties securing red and black wires using side cutter pliers; Remark:
RPM LED Fault Light Assembly Replacement
9354 9354 - Open Control RPM door to identify wiring connections (for pedestrian monitors... Instruction 9409 - 9354 - Open Control RPM door to identify wiring connections (for pedestrian monitors...; Remark:9529 STEP: 9409 - 9354 - Open Control RPM door to identify wiring connections (for pedestrian monitors...; Remark:9529
RPM LED Fault Light Assembly Replacement
9355 9355 - Remove connectors by cutting wires as close as possible to end of each connec... Instruction 9410 - 9355 - Remove connectors by cutting wires as close as possible to end of each connec...; Remark: STEP: 9410 - 9355 - Remove connectors by cutting wires as close as possible to end of each connec...; Remark:
RPM LED Fault Light Assembly Replacement
9356 9356 - Remove any wire ties securing wires using side cutter pliers Instruction 9411 - 9356 - Remove any wire ties securing wires using side cutter pliers; Remark: STEP: 9411 - 9356 - Remove any wire ties securing wires using side cutter pliers; Remark:
RPM LED Fault Light Assembly Replacement
9357 9357 - Uninstall Fault Light Hardware Instruction 9405 - 9357 - Uninstall Fault Light Hardware; Remark: STEP: 9405 - 9357 - Uninstall Fault Light Hardware; Remark:
RPM LED Fault Light Assembly Replacement
9358 9358 - Gently pry fault light cover off Instruction 9400 - 9358 - Gently pry fault light cover off; Remark:9528 STEP: 9400 - 9358 - Gently pry fault light cover off; Remark:9528
RPM LED Fault Light Assembly Replacement
9359 9359 - Install new fault light housing to front of door Instruction 9401 - 9359 - Install new fault light housing to front of door; Remark:9343 STEP: 9401 - 9359 - Install new fault light housing to front of door; Remark:9343
RPM LED Fault Light Assembly Replacement
9360 9360 - Remove fault light back plate by rotating it 45 degrees counterclockwise and ... Instruction 9402 - 9360 - Remove fault light back plate by rotating it 45 degrees counterclockwise and ...; Remark:9527 STEP: 9402 - 9360 - Remove fault light back plate by rotating it 45 degrees counterclockwise and ...; Remark:9527
RPM LED Fault Light Assembly Replacement
9361 9361 - Pull fault light socket through hole in door Instruction 9403 - 9361 - Pull fault light socket through hole in door; Remark: STEP: 9403 - 9361 - Pull fault light socket through hole in door; Remark:
RPM LED Fault Light Assembly Replacement
9362 9362 - Remove any leftover silicone from hole in door using flathead screwdriver... Instruction 9404 - 9362 - Remove any leftover silicone from hole in door using flathead screwdriver...; Remark:9526 STEP: 9404 - 9362 - Remove any leftover silicone from hole in door using flathead screwdriver...; Remark:9526
RPM LED Fault Light Assembly Replacement
9363 9363 - Install New Fault Light Hardware Instruction 9399 - 9363 - Install New Fault Light Hardware; Remark: STEP: 9399 - 9363 - Install New Fault Light Hardware; Remark:
RPM LED Fault Light Assembly Replacement
9364 9364 - Feed wires of new fault light assembly through hole in door Instruction 9395 - 9364 - Feed wires of new fault light assembly through hole in door; Remark: STEP: 9395 - 9364 - Feed wires of new fault light assembly through hole in door; Remark:
RPM LED Fault Light Assembly Replacement
9365 9365 - Install new fault light housing to front of door Instruction 9396 - 9365 - Install new fault light housing to front of door; Remark:9344 STEP: 9396 - 9365 - Install new fault light housing to front of door; Remark:9344
RPM LED Fault Light Assembly Replacement
9366 9366 - Apply silicone around the rim of socket on back of door Instruction 9397 - 9366 - Apply silicone around the rim of socket on back of door; Remark:9536 STEP: 9397 - 9366 - Apply silicone around the rim of socket on back of door; Remark:9536
RPM LED Fault Light Assembly Replacement
9367 9367 - Install new fault light cover to front of door Instruction 9398 - 9367 - Install new fault light cover to front of door; Remark: STEP: 9398 - 9367 - Install new fault light cover to front of door; Remark:
RPM LED Fault Light Assembly Replacement
9368 9368 - Reconnect LED Fault Light Wiring Instruction 9394 - 9368 - Reconnect LED Fault Light Wiring; Remark: STEP: 9394 - 9368 - Reconnect LED Fault Light Wiring; Remark:
RPM LED Fault Light Assembly Replacement
9369 9369 - Open Control pillar door to access terminal block (TB4) on back of door Instruction 9387 - 9369 - Open Control pillar door to access terminal block (TB4) on back of door; Remark:8674 STEP: 9387 - 9369 - Open Control pillar door to access terminal block (TB4) on back of door; Remark:8674
RPM LED Fault Light Assembly Replacement
9370 9370 - Reinstall black wire (TB4-3) and black wire (TB4-4) wiring into TB4 using a s... Instruction 9388 - 9370 - Reinstall black wire (TB4-3) and black wire (TB4-4) wiring into TB4 using a s...; Remark:9535 STEP: 9388 - 9370 - Reinstall black wire (TB4-3) and black wire (TB4-4) wiring into TB4 using a s...; Remark:9535
RPM LED Fault Light Assembly Replacement
9371 9371 - Add ties to secure wires where needed Instruction 9389 - 9371 - Add ties to secure wires where needed; Remark: STEP: 9389 - 9371 - Add ties to secure wires where needed; Remark:
RPM LED Fault Light Assembly Replacement
9372 9372 - Open Control RPM door to access fault light connections (for pedestrian monit... Instruction 9390 - 9372 - Open Control RPM door to access fault light connections (for pedestrian monit...; Remark:9534 STEP: 9390 - 9372 - Open Control RPM door to access fault light connections (for pedestrian monit...; Remark:9534
RPM LED Fault Light Assembly Replacement
9373 9373 - Strip 1 cm from end of connecting wires using crimping tool Instruction 9391 - 9373 - Strip 1 cm from end of connecting wires using crimping tool; Remark:9533 STEP: 9391 - 9373 - Strip 1 cm from end of connecting wires using crimping tool; Remark:9533
RPM LED Fault Light Assembly Replacement
9374 9374 - Remove sheathing from end of fault light wires using crimping tool Instruction 9392 - 9374 - Remove sheathing from end of fault light wires using crimping tool; Remark:9532 STEP: 9392 - 9374 - Remove sheathing from end of fault light wires using crimping tool; Remark:9532
RPM LED Fault Light Assembly Replacement
9375 9375 - Crimp union connectors to appropriate wires using a crimping tool Instruction 9393 - 9375 - Crimp union connectors to appropriate wires using a crimping tool; Remark:9345 STEP: 9393 - 9375 - Crimp union connectors to appropriate wires using a crimping tool; Remark:9345
RPM LED Fault Light Assembly Replacement
9376 9376 - Test Proper Light Operation Instruction 9386 - 9376 - Test Proper Light Operation; Remark:
9377 9377 - Switch LD-260 to on position while watching new LED fault light Instruction 9384 - 9377 - Switch LD-260 to on position while watching new LED fault light; Remark:9346
9381 9381 - 9379 - Document maintenance performed, times, and results for inclusion in correctiv...; Remark: Procedure Step
9382 9382 - 4705 - Submit report; Remark:2867 Procedure Step
9383 9383 - 321 - Document Maintenance Actions; Remark: Procedure Step
9384 9384 - 9377 - Switch LD-260 to on position while watching new LED fault light; Remark:9346 Procedure Step
9385 9385 - 319 - Perform operational test; Remark:9347 Procedure Step
9386 9386 - 9376 - Test Proper Light Operation; Remark: Procedure Step
9387 9387 - 9369 - Open Control pillar door to access terminal block (TB4) on back of door; Remark:8674 Procedure Step
9388 9388 - 9370 - Reinstall black wire (TB4-3) and black wire (TB4-4) wiring into TB4 using a s...; Remark:9535 Procedure Step
9389 9389 - 9371 - Add ties to secure wires where needed; Remark: Procedure Step
9390 9390 - 9372 - Open Control RPM door to access fault light connections (for pedestrian monit...; Remark:9534 Procedure Step
9391 9391 - 9373 - Strip 1 cm from end of connecting wires using crimping tool; Remark:9533 Procedure Step
9392 9392 - 9374 - Remove sheathing from end of fault light wires using crimping tool; Remark:9532 Procedure Step
9393 9393 - 9375 - Crimp union connectors to appropriate wires using a crimping tool; Remark:9345 Procedure Step
9394 9394 - 9368 - Reconnect LED Fault Light Wiring; Remark: Procedure Step
9395 9395 - 9364 - Feed wires of new fault light assembly through hole in door; Remark: Procedure Step
9396 9396 - 9365 - Install new fault light housing to front of door; Remark:9344 Procedure Step
9397 9397 - 9366 - Apply silicone around the rim of socket on back of door; Remark:9536 Procedure Step
9398 9398 - 9367 - Install new fault light cover to front of door; Remark: Procedure Step
9399 9399 - 9363 - Install New Fault Light Hardware; Remark: Procedure Step
9400 9400 - 9358 - Gently pry fault light cover off; Remark:9528 Procedure Step
9401 9401 - 9359 - Install new fault light housing to front of door; Remark:9343 Procedure Step
9402 9402 - 9360 - Remove fault light back plate by rotating it 45 degrees counterclockwise and ...; Remark:9527 Procedure Step
9403 9403 - 9361 - Pull fault light socket through hole in door; Remark: Procedure Step
9404 9404 - 9362 - Remove any leftover silicone from hole in door using flathead screwdriver...; Remark:9526 Procedure Step
9405 9405 - 9357 - Uninstall Fault Light Hardware; Remark: Procedure Step
9406 9406 - 9351 - Open Control door to access terminal block (TB4) on the back of the door ...; Remark:8674 Procedure Step
9407 9407 - 9352 - Remove black wire (TB4-3) and black wire (TB4-4) from TB4 using a small flath...; Remark:9530 Procedure Step
9408 9408 - 9353 - Remove any wire ties securing red and black wires using side cutter pliers; Remark: Procedure Step
9409 9409 - 9354 - Open Control RPM door to identify wiring connections (for pedestrian monitors...; Remark:9529 Procedure Step
9410 9410 - 9355 - Remove connectors by cutting wires as close as possible to end of each connec...; Remark: Procedure Step
9411 9411 - 9356 - Remove any wire ties securing wires using side cutter pliers; Remark: Procedure Step
9412 9412 - 9350 - Disconnect LED Fault Light Wiring; Remark: Procedure Step
9413 9413 - 7592 - Inform system operators upon arrival; Remark: Procedure Step
9414 9414 - 7676 - Brief system operators on expected work, duration, anticipated alarms, and fa...; Remark: Procedure Step
9415 9415 - 7967 - Close lane and set up barriers or establish a safety watch; Remark:7595 Procedure Step
9416 9416 - 9348 - Open Control pillar radiation portal monitor (RPM) door; Remark: Procedure Step
9418 9418 - 1401 - Establish Initial Conditions; Remark: Procedure Step
9420 9420 - Verify appropriate USB‑to-serial drivers are installed for adapter Instruction 9509 - 9420 - Verify appropriate USB‑to-serial drivers are installed for adapter; Remark:9458 STEP: 9509 - 9420 - Verify appropriate USB‑to-serial drivers are installed for adapter; Remark:9458
RPM SC-770 Rabbit Board Firmware Update
9421 9421 - Verify RFU software is installed Instruction 9510 - 9421 - Verify RFU software is installed; Remark:9459 STEP: 9510 - 9421 - Verify RFU software is installed; Remark:9459
RPM SC-770 Rabbit Board Firmware Update
9422 9422 - Start RFU software Instruction 9511 - 9422 - Start RFU software; Remark:9460 STEP: 9511 - 9422 - Start RFU software; Remark:9460
RPM SC-770 Rabbit Board Firmware Update
9423 9423 - Select “Communications” from Setup File Menu Instruction 9512 - 9423 - Select “Communications” from Setup File Menu; Remark:9542 STEP: 9512 - 9423 - Select “Communications” from Setup File Menu; Remark:9542
RPM SC-770 Rabbit Board Firmware Update
9424 9424 - Verify Comm Port is same on USB-to-serial driver and RFU software Instruction 9513 - 9424 - Verify Comm Port is same on USB-to-serial driver and RFU software; Remark:9461 STEP: 9513 - 9424 - Verify Comm Port is same on USB-to-serial driver and RFU software; Remark:9461
RPM SC-770 Rabbit Board Firmware Update
9425 9425 - Verify Baud Rate is same on USB-to-serial driver and RFU software Instruction 9514 - 9425 - Verify Baud Rate is same on USB-to-serial driver and RFU software; Remark:9462 STEP: 9514 - 9425 - Verify Baud Rate is same on USB-to-serial driver and RFU software; Remark:9462
RPM SC-770 Rabbit Board Firmware Update
9426 9426 - Verify remaining RFU software parameters Instruction 9515 - 9426 - Verify remaining RFU software parameters; Remark:9463 STEP: 9515 - 9426 - Verify remaining RFU software parameters; Remark:9463
RPM SC-770 Rabbit Board Firmware Update
9427 9427 - Click “OK” to close Communications Options Instruction 9516 - 9427 - Click “OK” to close Communications Options; Remark: STEP: 9516 - 9427 - Click “OK” to close Communications Options; Remark:
RPM SC-770 Rabbit Board Firmware Update
9428 9428 - Brief system operators on expected work, duration, anticipated alarms, and fa... Instruction 9500 - 9428 - Brief system operators on expected work, duration, anticipated alarms, and fa...; Remark:7677
9429 9429 - Wait for system to perform self-test followed by background radiation measure... Instruction 9503 - 9429 - Wait for system to perform self-test followed by background radiation measure...; Remark:
9430 9430 - Verify existing firmware is not current Instruction 9504 - 9430 - Verify existing firmware is not current; Remark:9464 STEP: 9504 - 9430 - Verify existing firmware is not current; Remark:9464
RPM SC-770 Rabbit Board Firmware Update
9431 9431 - Record parameter settings Instruction 9505 - 9431 - Record parameter settings; Remark:9466 STEP: 9505 - 9431 - Record parameter settings; Remark:9466
RPM SC-770 Rabbit Board Firmware Update
9434 9434 - Connect Computer to Rabbit Board Instruction 9498 - 9434 - Connect Computer to Rabbit Board; Remark: STEP: 9498 - 9434 - Connect Computer to Rabbit Board; Remark:
RPM SC-770 Rabbit Board Firmware Update