8953 |
8953 - Connect green wire to TB2, Pin 6 |
Instruction |
8967 - 8953 - Connect green wire to TB2, Pin 6; Remark:8952 |
STEP: 8967 - 8953 - Connect green wire to TB2, Pin 6; Remark:8952 RPM SPY-2 to IXIO-DT1 Occupancy Sensor Conversion |
✔ |
8954 |
8954 - Black is the ground wire. White is the common wire |
Remark |
8966 - 8955 - Connect both black and white wires to TB2, Pin 15; Remark:8954 |
STEP: 8966 - 8955 - Connect both black and white wires to TB2, Pin 15; Remark:8954 RPM SPY-2 to IXIO-DT1 Occupancy Sensor Conversion |
✔ |
8955 |
8955 - Connect both black and white wires to TB2, Pin 15 |
Instruction |
8966 - 8955 - Connect both black and white wires to TB2, Pin 15; Remark:8954 |
STEP: 8966 - 8955 - Connect both black and white wires to TB2, Pin 15; Remark:8954 RPM SPY-2 to IXIO-DT1 Occupancy Sensor Conversion |
✔ |
8956 |
8956 - Red is power (+12 VDC) wire. |
Remark |
8965 - 8958 - Connect red wire to TB2, Pin 16; Remark:8956 |
STEP: 8965 - 8958 - Connect red wire to TB2, Pin 16; Remark:8956 RPM SPY-2 to IXIO-DT1 Occupancy Sensor Conversion |
✔ |
8957 |
8957 - For models with older terminal blocks, it may be necessary to use a fork conn... |
Remark |
8965 - 8958 - Connect red wire to TB2, Pin 16; Remark:8956 |
STEP: 8965 - 8958 - Connect red wire to TB2, Pin 16; Remark:8956 RPM SPY-2 to IXIO-DT1 Occupancy Sensor Conversion |
✔ |
8958 |
8958 - Connect red wire to TB2, Pin 16 |
Instruction |
8965 - 8958 - Connect red wire to TB2, Pin 16; Remark:8956 |
STEP: 8965 - 8958 - Connect red wire to TB2, Pin 16; Remark:8956 RPM SPY-2 to IXIO-DT1 Occupancy Sensor Conversion |
✔ |
8959 |
8959 - New IXIO-DT1 cable should be routed along existing SPY-2 cable. Cable ties ma... |
Remark |
8964 - 8960 - Route new cable to TB2; Remark:8959 |
STEP: 8964 - 8960 - Route new cable to TB2; Remark:8959 RPM SPY-2 to IXIO-DT1 Occupancy Sensor Conversion |
✔ |
8960 |
8960 - Route new cable to TB2 |
Instruction |
8964 - 8960 - Route new cable to TB2; Remark:8959 |
STEP: 8964 - 8960 - Route new cable to TB2; Remark:8959 RPM SPY-2 to IXIO-DT1 Occupancy Sensor Conversion |
✔ |
8961 |
8961 - Do not remove existing occupancy sensor from door panel. Disconnect SPY-2 wir... |
Remark |
8963 - 8962 - Disconnect existing SPY-2 wiring; Remark:8961 |
STEP: 8963 - 8962 - Disconnect existing SPY-2 wiring; Remark:8961 RPM SPY-2 to IXIO-DT1 Occupancy Sensor Conversion |
✔ |
8962 |
8962 - Disconnect existing SPY-2 wiring |
Instruction |
8963 - 8962 - Disconnect existing SPY-2 wiring; Remark:8961 |
STEP: 8963 - 8962 - Disconnect existing SPY-2 wiring; Remark:8961 RPM SPY-2 to IXIO-DT1 Occupancy Sensor Conversion |
✔ |
8963 |
8963 - 8962 - Disconnect existing SPY-2 wiring; Remark:8961 |
Procedure Step |
|
|
✔ |
8964 |
8964 - 8960 - Route new cable to TB2; Remark:8959 |
Procedure Step |
|
|
✔ |
8965 |
8965 - 8958 - Connect red wire to TB2, Pin 16; Remark:8956 |
Procedure Step |
|
|
✔ |
8966 |
8966 - 8955 - Connect both black and white wires to TB2, Pin 15; Remark:8954 |
Procedure Step |
|
|
✔ |
8967 |
8967 - 8953 - Connect green wire to TB2, Pin 6; Remark:8952 |
Procedure Step |
|
|
✔ |
8968 |
8968 - 8951 - Apply sealant if needed; Remark:8950 |
Procedure Step |
|
|
✔ |
8969 |
8969 - Connect Wiring to RPM |
Instruction |
8970 - 8969 - Connect Wiring to RPM; Remark: |
STEP: 8970 - 8969 - Connect Wiring to RPM; Remark: RPM SPY-2 to IXIO-DT1 Occupancy Sensor Conversion |
✔ |
8970 |
8970 - 8969 - Connect Wiring to RPM; Remark: |
Procedure Step |
|
|
✔ |
8971 |
8971 - Re-route pedestrian traffic. |
Remark |
|
|
✔ |
8972 |
8972 - 7231 - Close lane; Remark:7415 |
Procedure Step |
|
|
✔ |
8973 |
8973 - Left latch on the LCD screen will indicate a “closed” circuit. |
Remark |
7471 - 7444 - Verify occupancy sensor functionality; Remark:7445 |
STEP: 7471 - 7444 - Verify occupancy sensor functionality; Remark:7445 RPM IXIO-DT1 Occupancy Sensor Replacement RPM SPY-2 to IXIO-DT1 Occupancy Sensor Conversion |
✔ |
8974 |
8974 - SC-770 status will read “OCCUPIED”. |
Remark |
7471 - 7444 - Verify occupancy sensor functionality; Remark:7445 |
STEP: 7471 - 7444 - Verify occupancy sensor functionality; Remark:7445 RPM IXIO-DT1 Occupancy Sensor Replacement RPM SPY-2 to IXIO-DT1 Occupancy Sensor Conversion |
✔ |
8975 |
8975 - Adjust output voltage to +14.6 VDC |
Troubleshoot Element Text |
8980 - 8975 - Adjust output voltage to +14.6 VDC - Decision, Notes: 9041 |
|
✔ |
8976 |
8976 - Measure the output of the +15 VDC power supply. |
Remark |
|
|
✔ |
8977 |
8977 - The optimal output voltage is +14.6 VDC. |
Remark |
|
|
✔ |
8978 |
8978 - Attempt to adjust the output voltage from the +15 VDC power supply using the ... |
Remark |
|
|
✔ |
8979 |
8979 - Were you able to adjust the voltage? |
Remark |
|
|
✔ |
8981 |
8981 - 120/240 VAC present at power supply? |
Troubleshoot Element Text |
8987 - 8981 - 120/240 VAC present at power supply? - Decision, Notes: 8982 |
|
✔ |
8982 |
8982 - Using a digital multimeter in AC mode |
Remark |
|
|
✔ |
8983 |
8983 - Measure the AC voltage at the input to the 15 VDC power supply |
Remark |
|
|
✔ |
8984 |
8984 - A plexiglas cover may have to be removed to perform this measurement |
Remark |
|
|
✔ |
8985 |
8985 - Is 120/240 VAC present? |
Remark |
|
|
✔ |
8986 |
8986 - Warning : The technician performing this measurement should be appropriately trained an... |
Annotation |
8873 - 8869 - Inspect Wiring/Connections/Breaker - Process, Notes: 8870 8987 - 8981 - 120/240 VAC present at power supply? - Decision, Notes: 8982 8996 - 8994 - 120/240 VAC present? - Process, Notes: 8982 |
|
✔ |
8988 |
8988 - Contact Facilities |
Troubleshoot Element Text |
8992 - 8988 - Contact Facilities - Incomplete, Notes: 8989 |
|
✔ |
8989 |
8989 - If 120/240 VAC is not present at the supply side of the RPM input breaker, th... |
Remark |
|
|
✔ |
8990 |
8990 - If the AC power is supplied from an NSDD-installed lane side utility panel, b... |
Remark |
|
|
✔ |
8991 |
8991 - If the AC power is supplied from site power, contact the organization respons... |
Remark |
|
|
✔ |
8993 |
8993 - Warning : The 120/240 VAC terminal is adjacent to the DC output terminals. |
Annotation |
8980 - 8975 - Adjust output voltage to +14.6 VDC - Decision, Notes: 9041 11479 - 11478 - Adjust Output Voltage to 15VDC - Process, Notes: 11488 |
STEP: 11479 - 11478 - Adjust Output Voltage to 15VDC - Process, Notes: 11488 Rapiscan RPM VM-250, TM-850 Troubleshooting Rapiscan RPM VM-250, TM-850 Troubleshooting Rapiscan PM-700 Rapiscan PM-700 120/240 VAC Power Distribution |
✔ |
8994 |
8994 - 120/240 VAC present? |
Troubleshoot Element Text |
8996 - 8994 - 120/240 VAC present? - Process, Notes: 8982 |
|
✔ |
8995 |
8995 - measure the voltage potential between the bottom terminal of the AC input bre... |
Remark |
|
|
✔ |
8997 |
8997 - Start |
Troubleshoot Element Text |
8999 - 8997 - AC LED on LD-260 illuminated? - Decision, Notes: 8998 9005 - 8997 - AC LED on LD-260 illuminated? - Decision, Notes: 8998 9072 - 8997 - AC LED on LD-260 illuminated? - Decision, Notes: 8998 9083 - 8997 - Start - Begin, Notes: 9204 - 8997 - AC LED on LD-260 illuminated? - Decision, Notes: 8998 11474 - 8997 - Start - Begin, Notes: |
STEP: 9083 - 8997 - Start - Begin, Notes: Rapiscan RPM VM-250, TM-850 Troubleshooting Rapiscan RPM VM-250, TM-850 Troubleshooting Rapiscan PM-700 Rapiscan PM-700 15 VDC Power Distribution
STEP: 9204 - 8997 - AC LED on LD-260 illuminated? - Decision, Notes: 8998 Rapiscan RPM VM-250, TM-850 Troubleshooting Rapiscan PM-700 Rapiscan RPM VM-250, TM-850 Troubleshooting Rapiscan PM-700
STEP: 11474 - 8997 - Start - Begin, Notes: Rapiscan RPM VM-250, TM-850 Troubleshooting Rapiscan RPM VM-250, TM-850 Troubleshooting Rapiscan PM-700 Rapiscan PM-700 120/240 VAC Power Distribution |
✔ |
8998 |
8998 - Is the AC LED on the LD-260 illuminated? |
Remark |
|
|
✔ |
9000 |
9000 - AC LED on LD-260 illuminated? |
Troubleshoot Element Text |
9004 - 9000 - AC LED on LD-260 illuminated? - Decision, Notes: 8998 11481 - 9000 - AC LED on LD-260 illuminated? - Decision, Notes: 11518 - 9000 - AC LED on LD-260 illuminated? - Decision, Notes: 11520 - 9000 - AC LED on LD-260 illuminated? - Decision, Notes: 8998 |
STEP: 9004 - 9000 - AC LED on LD-260 illuminated? - Decision, Notes: 8998 Rapiscan RPM VM-250, TM-850 Troubleshooting Rapiscan RPM VM-250, TM-850 Troubleshooting Rapiscan PM-700 Rapiscan PM-700 120/240 VAC Power Distribution
STEP: 11481 - 9000 - AC LED on LD-260 illuminated? - Decision, Notes: Rapiscan RPM VM-250, TM-850 Troubleshooting Rapiscan RPM VM-250, TM-850 Troubleshooting Rapiscan PM-700 Rapiscan PM-700 120/240 VAC Power Distribution
STEP: 11520 - 9000 - AC LED on LD-260 illuminated? - Decision, Notes: 8998 Rapiscan RPM VM-250, TM-850 Troubleshooting Rapiscan RPM VM-250, TM-850 Troubleshooting Rapiscan PM-700 Rapiscan PM-700 15 VDC Power Distribution |
✔ |
9001 |
9001 - The AC circuit breaker might be tripped. |
Remark |
|
|
✔ |
9002 |
9002 - Reset the circuit breaker at the bottom of the RPM control pillar. |
Remark |
|
|
✔ |
9003 |
9003 - If the breaker trips again, there is likely a ground fault that should be loc... |
Remark |
|
|
✔ |
9006 |
9006 - Replace LD-260 |
Troubleshoot Element Text |
9009 - 9006 - Replace LD-260 - Formal Procedure, Notes: 9007 |
STEP: 9009 - 9006 - Replace LD-260 - Formal Procedure, Notes: 9007 Rapiscan RPM VM-250, TM-850 Troubleshooting Rapiscan RPM VM-250, TM-850 Troubleshooting Rapiscan PM-700 Rapiscan PM-700 15 VDC Power Distribution Rapiscan RPM VM-250, TM-850 Troubleshooting Rapiscan PM-700 |
✔ |
9007 |
9007 - Perform the following procedure: |
Remark |
|
|
✔ |
9008 |
9008 - DET-RPM-RAP-CM06, RPM LD-260 Load Disconnect Replacement. |
Remark |
|
|
✔ |
9010 |
9010 - DET-RPM-RAP-CM26, +15 VDC Power Supply Replacement |
Remark |
|
|
✔ |
9011 |
9011 - Replace LD-260 Fuse |
Troubleshoot Element Text |
9013 - 9011 - Replace LD-260 Fuse - Formal Procedure, Notes: 9007 |
STEP: 9013 - 9011 - Replace LD-260 Fuse - Formal Procedure, Notes: 9007 Rapiscan RPM VM-250, TM-850 Troubleshooting Rapiscan RPM VM-250, TM-850 Troubleshooting Rapiscan PM-700 Rapiscan PM-700 15 VDC Power Distribution |
✔ |
9012 |
9012 - DET-RPM-RAP-CM05, RPM LD-260 Load Disconnect Fuse Replacement. |
Remark |
|
|
✔ |
9014 |
9014 - Troubleshoot component power issue. |
Troubleshoot Element Text |
|
|
✔ |
9015 |
9015 - Reconnect LD-260 Molex J2 and J4 connectors |
Remark |
|
|
✔ |
9016 |
9016 - There might be an individual component causing the power issues. |
Remark |
|
|
✔ |
9017 |
9017 - Isolate faulty component by systematically disconnecting power to each compon... |
Remark |
|
|
✔ |
9019 |
9019 - Inspect Wiring |
Troubleshoot Element Text |
9022 - 9019 - Inspect Wiring - Process, Notes: 9020 9024 - 9019 - Inspect Wiring - Process, Notes: 9023 11493 - 9019 - Inspect Wiring - Process, Notes: 8982 11505 - 9019 - Inspect Wiring - Process, Notes: 8982 |
STEP: 11505 - 9019 - Inspect Wiring - Process, Notes: 8982 Rapiscan RPM VM-250, TM-850 Troubleshooting Rapiscan RPM VM-250, TM-850 Troubleshooting Rapiscan PM-700 Rapiscan PM-700 120/240 VAC Power Distribution |
✔ |
9020 |
9020 - Check and reseat wiring/connectors between terminal block TB-1 pins 1, 2, or ... |
Remark |
|
|
✔ |
9021 |
9021 - Refer to the +15 VDC distribution block diagram for more information. |
Remark |
|
|
✔ |
9023 |
9023 - Check and reseat wiring/connectors between LD-260 output Molex J4 and termina... |
Remark |
|
|
✔ |
9025 |
9025 - Possible Component Failure |
Troubleshoot Element Text |
9028 - 9025 - Possible Component Failure - Process, Notes: 9026 10052 - 9025 - Possible Component Failure - Decision, Notes: 10049 |
STEP: 10052 - 9025 - Possible Component Failure - Decision, Notes: 10049 Rapiscan RPM VM-250, TM-850 Troubleshooting Rapiscan RPM VM-250, TM-850 Troubleshooting Rapiscan PM-700 |
✔ |
9026 |
9026 - Replace the component. |
Remark |
|
|
✔ |
9027 |
9027 - Refer to applicable procedure for more information about replacement. |
Remark |
|
|
✔ |
9029 |
9029 - Replace RPM Battery |
Troubleshoot Element Text |
9031 - 9029 - Replace RPM Battery - Formal Procedure, Notes: 9007 |
STEP: 9031 - 9029 - Replace RPM Battery - Formal Procedure, Notes: 9007 Rapiscan RPM VM-250, TM-850 Troubleshooting Rapiscan RPM VM-250, TM-850 Troubleshooting Rapiscan PM-700 Rapiscan PM-700 15 VDC Power Distribution |
✔ |
9030 |
9030 - DET-RPM-RAP-CM28, +12 VDC Battery Replacement |
Remark |
|
|
✔ |
9032 |
9032 - PWR ON LED on the LD-260 illuminated? |
Troubleshoot Element Text |
9034 - 9032 - PWR ON LED on the LD-260 illuminated? - Decision, Notes: 9033 9052 - 9032 - PWR ON LED on the LD-260 illuminated? - Decision, Notes: 9033 9066 - 9032 - PWR ON LED on the LD-260 illuminated? - Decision, Notes: 9033 11519 - 9032 - PWR LED on the LD-260 illuminated? - Decision, Notes: |
STEP: 9034 - 9032 - PWR ON LED on the LD-260 illuminated? - Decision, Notes: 9033 Rapiscan RPM VM-250, TM-850 Troubleshooting Rapiscan RPM VM-250, TM-850 Troubleshooting Rapiscan PM-700 Rapiscan PM-700 15 VDC Power Distribution
STEP: 9052 - 9032 - PWR ON LED on the LD-260 illuminated? - Decision, Notes: 9033 Rapiscan RPM VM-250, TM-850 Troubleshooting Rapiscan RPM VM-250, TM-850 Troubleshooting Rapiscan PM-700 Rapiscan PM-700 15 VDC Power Distribution
STEP: 9066 - 9032 - PWR ON LED on the LD-260 illuminated? - Decision, Notes: 9033 Rapiscan RPM VM-250, TM-850 Troubleshooting Rapiscan RPM VM-250, TM-850 Troubleshooting Rapiscan PM-700 Rapiscan PM-700 15 VDC Power Distribution |
✔ |
9033 |
9033 - Is the PWR ON LED on the LD-260 illuminated? |
Remark |
|
|
✔ |
9035 |
9035 - Disconnect LD-260 Molex Connectors |
Troubleshoot Element Text |
9039 - 9035 - Disconnect LD-260 Molex Connectors - Process, Notes: 9036 |
STEP: 9039 - 9035 - Disconnect LD-260 Molex Connectors - Process, Notes: 9036 Rapiscan RPM VM-250, TM-850 Troubleshooting Rapiscan RPM VM-250, TM-850 Troubleshooting Rapiscan PM-700 Rapiscan PM-700 15 VDC Power Distribution |
✔ |
9036 |
9036 - Reinstall retained cover screws and toggle switch nut on LD-260. |
Remark |
|
|
✔ |
9037 |
9037 - Replace nut on toggle switch |
Remark |
|
|
✔ |
9038 |
9038 - Disconnect Molex J2 and J4 connectors |
Remark |
|
|
✔ |
9040 |
9040 - +15 VDC at LD-260 Output? |
Troubleshoot Element Text |
9044 - 9040 - +15 VDC at LD-260 Output? - Decision, Notes: 9041 |
|
✔ |
9041 |
9041 - Using a digital multimeter in DC mode,verify 15 VDC at TB1 pins 1, 2, and 3. |
Remark |
|
|
✔ |
9042 |
9042 - measure the voltage at LD-260 output, Molex J4, between pins 4 and 5. |
Remark |
|
|
✔ |
9043 |
9043 - Is there approximately +15 VDC present? |
Remark |
|
|
✔ |
9045 |
9045 - LD-260 Fuse Failed? |
Troubleshoot Element Text |
9051 - 9045 - LD-260 Fuse Failed? - Decision, Notes: 9046 |
STEP: 9051 - 9045 - LD-260 Fuse Failed? - Decision, Notes: 9046 Rapiscan RPM VM-250, TM-850 Troubleshooting Rapiscan RPM VM-250, TM-850 Troubleshooting Rapiscan PM-700 Rapiscan PM-700 15 VDC Power Distribution |
✔ |
9046 |
9046 - Turn off power to the RPM at the AC input breaker |
Remark |
|
|
✔ |
9047 |
9047 - Reconnect RPM Battery |
Remark |
|
|
✔ |
9048 |
9048 - Remove and retain four (4) cover plate screws and nut on toggle switch |
Remark |
|
|
✔ |
9049 |
9049 - Examine fuse visually. |
Remark |
|
|
✔ |
9050 |
9050 - Or, check continuity with multi-meter. |
Remark |
|
|
✔ |
9053 |
9053 - Warning : Traffic should temporarily be rerouted or halted during conduction of this pr... |
Annotation |
7268 - 7231 - Close lane; Remark:7233 |
STEP: 7268 - 7231 - Close lane; Remark:7233 RPM LD-260 Load Disconnect Replacement RPM Ethernet-to-Fiber Media Converter Replacement RPM SCA-774 Single Channel Analyzer Board Replacement RPM SCA-775 Module Replacement RPM LD-260 Load Disconnect Fuse Replacement RPM SC-771 Controller Board Replacement RPM Gamma Detector Replacement RPM ThetaController Installation RPM SC-770 Controller Module Replacement RPM Neutron Detector Helium-3 (He3) Tube Replacement RPM RS232 to RS485 Converter Replacement RPM Banner IR Occupancy Sensor Replacement RPM Nano Controller Replacement RPM Neutron Signal Pick-Off Box (PMFX) Replacement RPM VD-580 Replacement RPM Tamper Switch Alignment, Replacement, and Repair RPM LED Fault Light Assembly Replacement RPM SC-770 Rabbit Board Firmware Update RPM AC Line Filter Replacement RPM +15Vdc Power Supply Replacement RPM AM-270 Remote Alarm Panel Replacement RPM +12 VDC Battery Replacement RPM Cabinet Door Gasket Replacement |
✔ |
9054 |
9054 - Disconnect RPM Battery |
Troubleshoot Element Text |
9057 - 9054 - Disconnect RPM Battery - Process, Notes: 9055 |
STEP: 9057 - 9054 - Disconnect RPM Battery - Process, Notes: 9055 Rapiscan RPM VM-250, TM-850 Troubleshooting Rapiscan RPM VM-250, TM-850 Troubleshooting Rapiscan PM-700 Rapiscan PM-700 15 VDC Power Distribution |
✔ |
9055 |
9055 - Isolate RPM battery from LD-260 by disconnecting J3 connector. |
Remark |
|
|
✔ |
9056 |
9056 - or, disconnecting the red wire from the battery terminal |
Remark |
|
|
✔ |
9058 |
9058 - +15 VDC at Component Input? |
Troubleshoot Element Text |
9062 - 9058 - +15 VDC at Component Input? - Decision, Notes: 9041 |
|
✔ |
9059 |
9059 - verify +15 VDC at Component power input. |
Remark |
|
|
✔ |
9060 |
9060 - Measurement location differs for each component. |
Remark |
|
|
✔ |
9061 |
9061 - Refer to wiring diagrams for more information. |
Remark |
|
|
✔ |
9063 |
9063 - 15 VDC at Terminal Block? |
Troubleshoot Element Text |
|
|
✔ |
9064 |
9064 - Pins 4, 5, and 6 are associated grounds. |
Remark |
|
|
✔ |
9067 |
9067 - 15 VDC at J3 Molex? |
Troubleshoot Element Text |
9070 - 9067 - 15 VDC at J3 Molex? - Decision, Notes: 9068 11535 - 9067 - 15 VDC at J3 Molex? - Decision, Notes: 11534 |
STEP: 11535 - 9067 - 15 VDC at J3 Molex? - Decision, Notes: 11534 Rapiscan RPM VM-250, TM-850 Troubleshooting Rapiscan RPM VM-250, TM-850 Troubleshooting Rapiscan PM-700 Rapiscan PM-700 15 VDC Power Distribution |
✔ |
9068 |
9068 - Disconnect LD-260 Molex J3 connector |
Remark |
|
|
✔ |
9069 |
9069 - measure the voltage between pin 2 and 3 |
Remark |
|
|
✔ |
9071 |
9071 - Use needle nose pliers. |
Remark |
8326 - 8322 - Reattach mounting springs; Remark:9071 |
STEP: 8326 - 8322 - Reattach mounting springs; Remark:9071 RPM Gamma Detector Replacement |
✔ |
9073 |
9073 - Replace J3 Molex Connector |
Troubleshoot Element Text |
9077 - 9073 - Replace J3 Molex Connector - Process, Notes: 9046 |
STEP: 9077 - 9073 - Replace J3 Molex Connector - Process, Notes: 9046 Rapiscan RPM VM-250, TM-850 Troubleshooting Rapiscan RPM VM-250, TM-850 Troubleshooting Rapiscan PM-700 Rapiscan PM-700 15 VDC Power Distribution |
✔ |
9074 |
9074 - Replace J3 Molex Connector from spare parts. |
Remark |
|
|
✔ |
9075 |
9075 - Reconnect J3 Molex connector to LD-260. |
Remark |
|
|
✔ |
9076 |
9076 - Turn on power to the RPM at the AC input breaker |
Remark |
|
|
✔ |
9078 |
9078 - Inspect LD-260 Molex J3 Connector |
Troubleshoot Element Text |
9082 - 9078 - Inspect LD-260 Molex J3 Connector - Decision, Notes: 9079 |
STEP: 9082 - 9078 - Inspect LD-260 Molex J3 Connector - Decision, Notes: 9079 Rapiscan RPM VM-250, TM-850 Troubleshooting Rapiscan RPM VM-250, TM-850 Troubleshooting Rapiscan PM-700 Rapiscan PM-700 15 VDC Power Distribution |
✔ |