9213 9213 - Firmly press VD-580 into place on PMT and reattach springs Instruction 9276 - 9213 - Firmly press VD-580 into place on PMT and reattach springs; Remark: STEP: 9276 - 9213 - Firmly press VD-580 into place on PMT and reattach springs; Remark:
RPM VD-580 Replacement
9214 9214 - Reconnect BNC and MHV cables to VD-580 Instruction 9277 - 9214 - Reconnect BNC and MHV cables to VD-580; Remark: STEP: 9277 - 9214 - Reconnect BNC and MHV cables to VD-580; Remark:
RPM VD-580 Replacement
9215 9215 - Verify detector count rate Instruction 9272 - 9215 - Verify detector count rate; Remark:9220 STEP: 9272 - 9215 - Verify detector count rate; Remark:9220
RPM VD-580 Replacement
9216 9216 - Reopen RPM Lane Instruction 9273 - 9216 - Reopen RPM Lane; Remark:
9218 9218 - Potted version has visible gel coating on circuit board. Remark 9282 - 9210 - Verify VD-580 to be installed is potted; Remark:9218 STEP: 9282 - 9210 - Verify VD-580 to be installed is potted; Remark:9218
RPM VD-580 Replacement
9219 9219 - Potted Version Remark 9282 - 9210 - Verify VD-580 to be installed is potted; Remark:9218 STEP: 9282 - 9210 - Verify VD-580 to be installed is potted; Remark:9218
RPM VD-580 Replacement
9220 9220 - Navigate to SHOW COUNTS on SC-770. Enter “Program Mode” by pres... Remark 9272 - 9215 - Verify detector count rate; Remark:9220 STEP: 9272 - 9215 - Verify detector count rate; Remark:9220
RPM VD-580 Replacement
9221 9221 - Note : Do not release the springs while they are under tension, the springs may fly ... Annotation 9280 - 9208 - Unhook springs from photomultiplier tube (PMT) using needle nose pliers; Remark: STEP: 9280 - 9208 - Unhook springs from photomultiplier tube (PMT) using needle nose pliers; Remark:
RPM VD-580 Replacement
9222 9222 - Note : It may be easier to install the rear spring first. You can install that spring b... Annotation 9276 - 9213 - Firmly press VD-580 into place on PMT and reattach springs; Remark: STEP: 9276 - 9213 - Firmly press VD-580 into place on PMT and reattach springs; Remark:
RPM VD-580 Replacement
9223 9223 - Remove PMFX Box Instruction 9265 - 9223 - Remove PMFX Box; Remark: STEP: 9265 - 9223 - Remove PMFX Box; Remark:
RPM Neutron Signal Pick-Off Box (PMFX) Replacement
9224 9224 - Disconnect all signal (BNC) and miniature high voltage (MHV) cables from PMFX... Instruction 9262 - 9224 - Disconnect all signal (BNC) and miniature high voltage (MHV) cables from PMFX...; Remark: STEP: 9262 - 9224 - Disconnect all signal (BNC) and miniature high voltage (MHV) cables from PMFX...; Remark:
RPM Neutron Signal Pick-Off Box (PMFX) Replacement
9225 9225 - Install New PMFX Box Instruction 9261 - 9225 - Install New PMFX Box; Remark: STEP: 9261 - 9225 - Install New PMFX Box; Remark:
RPM Neutron Signal Pick-Off Box (PMFX) Replacement
9226 9226 - Mount PMFX with four screws Instruction 9257 - 9226 - Mount PMFX with four screws; Remark:7807 STEP: 9257 - 9226 - Mount PMFX with four screws; Remark:7807
RPM Neutron Signal Pick-Off Box (PMFX) Replacement
9227 9227 - Reinstall four (4) cover screws Instruction 9258 - 9227 - Reinstall four (4) cover screws; Remark:7807 STEP: 9258 - 9227 - Reinstall four (4) cover screws; Remark:7807
RPM Neutron Signal Pick-Off Box (PMFX) Replacement
9228 9228 - Reconnect BNC and MHV connectors to PMFX box Instruction 9259 - 9228 - Reconnect BNC and MHV connectors to PMFX box; Remark: STEP: 9259 - 9228 - Reconnect BNC and MHV connectors to PMFX box; Remark:
RPM Neutron Signal Pick-Off Box (PMFX) Replacement
9229 9229 - Verify neutron counts Instruction 9254 - 9229 - Verify neutron counts; Remark:9231 STEP: 9254 - 9229 - Verify neutron counts; Remark:9231
RPM Neutron Signal Pick-Off Box (PMFX) Replacement
9230 9230 - Prepare Laptop and Software Instruction 9517 - 9230 - Prepare Laptop and Software; Remark: STEP: 9517 - 9230 - Prepare Laptop and Software; Remark:
RPM SC-770 Rabbit Board Firmware Update
9231 9231 - Neutron counts can be verified by placing Cf-252 source near front of neutron... Remark 9254 - 9229 - Verify neutron counts; Remark:9231 STEP: 9254 - 9229 - Verify neutron counts; Remark:9231
RPM Neutron Signal Pick-Off Box (PMFX) Replacement
9232 9232 - Non-potted version Remark 9264 - 445 - Remove four (4) mounting screws; Remark:9232 STEP: 9264 - 445 - Remove four (4) mounting screws; Remark:9232
RPM Neutron Signal Pick-Off Box (PMFX) Replacement
9233 9233 - Potted version Remark 9264 - 445 - Remove four (4) mounting screws; Remark:9232 STEP: 9264 - 445 - Remove four (4) mounting screws; Remark:9232
RPM Neutron Signal Pick-Off Box (PMFX) Replacement
9234 9234 - Access holes for retaining screws. Remark 9264 - 445 - Remove four (4) mounting screws; Remark:9232 STEP: 9264 - 445 - Remove four (4) mounting screws; Remark:9232
RPM Neutron Signal Pick-Off Box (PMFX) Replacement
9235 9235 - Open Control pillar RPM door Instruction 9337 - 9235 - Open Control pillar RPM door; Remark:
10264 - 9235 - Open Control pillar RPM door; Remark:
10268 - 9235 - Open Control pillar RPM door; Remark:
STEP: 10264 - 9235 - Open Control pillar RPM door; Remark:
RPM Alarm Strobe Light Assembly Replacement

STEP: 10268 - 9235 - Open Control pillar RPM door; Remark:
RPM ELK Siren Replacement
9236 9236 - Switch LD-260 to OFF position and verify green “PWR ON” LED is not lit Instruction 9338 - 9236 - Switch LD-260 to OFF position and verify green “PWR ON” LED is not lit; Remark:9525
10265 - 9236 - Switch LD-260 to OFF position and verify green “PWR ON” LED is not lit; Remark:10263
STEP: 10265 - 9236 - Switch LD-260 to OFF position and verify green “PWR ON” LED is not lit; Remark:10263
RPM Alarm Strobe Light Assembly Replacement
9237 9237 - Verify Alignment of Tamper Switch and Magnet Instruction 9333 - 9237 - Verify Alignment of Tamper Switch and Magnet; Remark: STEP: 9333 - 9237 - Verify Alignment of Tamper Switch and Magnet; Remark:
RPM Tamper Switch Alignment, Replacement, and Repair
9238 9238 - Measure distance from inside edge of cabinet to edge of tamper switch Instruction 9329 - 9238 - Measure distance from inside edge of cabinet to edge of tamper switch; Remark:9296 STEP: 9329 - 9238 - Measure distance from inside edge of cabinet to edge of tamper switch; Remark:9296
RPM Tamper Switch Alignment, Replacement, and Repair
9239 9239 - Measure distance from inside edge of door to edge of magnet Instruction 9330 - 9239 - Measure distance from inside edge of door to edge of magnet; Remark:9297 STEP: 9330 - 9239 - Measure distance from inside edge of door to edge of magnet; Remark:9297
RPM Tamper Switch Alignment, Replacement, and Repair
9240 9240 - Verify alignment of tamper switch and magnet Instruction 9331 - 9240 - Verify alignment of tamper switch and magnet; Remark:9298 STEP: 9331 - 9240 - Verify alignment of tamper switch and magnet; Remark:9298
RPM Tamper Switch Alignment, Replacement, and Repair
9241 9241 - Relocate tamper switch or magnet to correct any misalignment, if necessary Instruction 9332 - 9241 - Relocate tamper switch or magnet to correct any misalignment, if necessary; Remark:9299 STEP: 9332 - 9241 - Relocate tamper switch or magnet to correct any misalignment, if necessary; Remark:9299
RPM Tamper Switch Alignment, Replacement, and Repair
9242 9242 - Tamper Switch Replacement and Wiring Connection Instruction 9328 - 9242 - Tamper Switch Replacement and Wiring Connection; Remark: STEP: 9328 - 9242 - Tamper Switch Replacement and Wiring Connection; Remark:
RPM Tamper Switch Alignment, Replacement, and Repair
9243 9243 - 7592 - Inform system operators; Remark: Procedure Step
9244 9244 - 7676 - Brief system operators on expected work, duration, anticipated alarms, and fa...; Remark:7677 Procedure Step
9245 9245 - 7967 - Close lane and set up barriers or establish a safety watch; Remark:7595 Procedure Step
9247 9247 - 1401 - Establish Initial Conditions; Remark: Procedure Step
9249 9249 - 7820 - Inform system operators upon completion of maintenance action; Remark: Procedure Step
9252 9252 - 321 - Document Maintenance Actions; Remark: Procedure Step
9253 9253 - 7818 - Properly dispose of/control used parts; Remark:7875 Procedure Step
9254 9254 - 9229 - Verify neutron counts; Remark:9231 Procedure Step
9255 9255 - 8250 - Reopen Lane; Remark: Procedure Step
9256 9256 - 7249 - Return Equipment to Normal Operating Condition; Remark: Procedure Step
9257 9257 - 9226 - Mount PMFX with four screws; Remark:7807 Procedure Step
9258 9258 - 9227 - Reinstall four (4) cover screws; Remark:7807 Procedure Step
9259 9259 - 9228 - Reconnect BNC and MHV connectors to PMFX box; Remark: Procedure Step
9261 9261 - 9225 - Install New PMFX Box; Remark: Procedure Step
9262 9262 - 9224 - Disconnect all signal (BNC) and miniature high voltage (MHV) cables from PMFX...; Remark: Procedure Step
9263 9263 - 572 - Remove four (4) cover screws; Remark:9520 Procedure Step
9264 9264 - 445 - Remove four (4) mounting screws; Remark:9232 Procedure Step
9265 9265 - 9223 - Remove PMFX Box; Remark: Procedure Step
9268 9268 - 7821 - Document maintenance performed, times, and results for inclusion in correctiv...; Remark: Procedure Step
9270 9270 - 321 - Document maintenance actions; Remark: Procedure Step
9272 9272 - 9215 - Verify detector count rate; Remark:9220 Procedure Step
9273 9273 - 9216 - Reopen RPM Lane; Remark: Procedure Step
9274 9274 - 7249 - Return Equipment to Normal Operating Condition; Remark: Procedure Step
9275 9275 - 9212 - Line up alignment key and notch between PMT and VD‑580; Remark:9519 Procedure Step
9276 9276 - 9213 - Firmly press VD-580 into place on PMT and reattach springs; Remark: Procedure Step
9277 9277 - 9214 - Reconnect BNC and MHV cables to VD-580; Remark: Procedure Step
9278 9278 - 9211 - Install New VD-580; Remark: Procedure Step
9279 9279 - 9207 - Disconnect BNC and MHV cables from VD-580 on top of gamma detector; Remark: Procedure Step
9280 9280 - 9208 - Unhook springs from photomultiplier tube (PMT) using needle nose pliers; Remark: Procedure Step
9281 9281 - 9209 - Pull VD-580 off gently to remove from PMT; Remark:9518 Procedure Step
9282 9282 - 9210 - Verify VD-580 to be installed is potted; Remark:9218 Procedure Step
9283 9283 - 8309 - Remove VD-580; Remark: Procedure Step
9284 9284 - 7592 - Inform system operators; Remark: Procedure Step
9285 9285 - 7676 - Brief system operators on expected work, duration, anticipated alarms, and fa...; Remark: Procedure Step
9286 9286 - 7967 - Close lane and set up barriers or establish a safety watch; Remark:7595 Procedure Step
9288 9288 - 1401 - Establish Initial Conditions; Remark: Procedure Step
9290 9290 - Remark
9291 9291 - Note : Depending on the age and model of RPM, the tamper switch may be held in place by... Annotation 9333 - 9237 - Verify Alignment of Tamper Switch and Magnet; Remark: STEP: 9333 - 9237 - Verify Alignment of Tamper Switch and Magnet; Remark:
RPM Tamper Switch Alignment, Replacement, and Repair
9292 9292 - Note : The troubleshooting process should determine if the reed switch is bad, or if th... Annotation 9333 - 9237 - Verify Alignment of Tamper Switch and Magnet; Remark: STEP: 9333 - 9237 - Verify Alignment of Tamper Switch and Magnet; Remark:
RPM Tamper Switch Alignment, Replacement, and Repair
9293 9293 - Note : Consider relocating the tamper switch, rather than the magnet, to minimize numbe... Annotation 9332 - 9241 - Relocate tamper switch or magnet to correct any misalignment, if necessary; Remark:9299 STEP: 9332 - 9241 - Relocate tamper switch or magnet to correct any misalignment, if necessary; Remark:9299
RPM Tamper Switch Alignment, Replacement, and Repair
9294 9294 - Caution : Wear safety glasses as appropriate. Annotation 9332 - 9241 - Relocate tamper switch or magnet to correct any misalignment, if necessary; Remark:9299 STEP: 9332 - 9241 - Relocate tamper switch or magnet to correct any misalignment, if necessary; Remark:9299
RPM Tamper Switch Alignment, Replacement, and Repair
9295 9295 - Note : Once you have made the repair or replaced the tamper switch, the tamper light wi... Annotation 9320 - 7249 - Return equipment to normal operating condition; Remark:
9296 9296 - There is no predetermined position of a tamper switch. The switch may be located... Remark 9329 - 9238 - Measure distance from inside edge of cabinet to edge of tamper switch; Remark:9296 STEP: 9329 - 9238 - Measure distance from inside edge of cabinet to edge of tamper switch; Remark:9296
RPM Tamper Switch Alignment, Replacement, and Repair
9297 9297 - The location of the magnet is determined by the location of the tamper switch. Remark 9330 - 9239 - Measure distance from inside edge of door to edge of magnet; Remark:9297 STEP: 9330 - 9239 - Measure distance from inside edge of door to edge of magnet; Remark:9297
RPM Tamper Switch Alignment, Replacement, and Repair
9298 9298 - The alignment of the magnet and the tamper switch need to be within 6 mm (1/4 in... Remark 9331 - 9240 - Verify alignment of tamper switch and magnet; Remark:9298 STEP: 9331 - 9240 - Verify alignment of tamper switch and magnet; Remark:9298
RPM Tamper Switch Alignment, Replacement, and Repair
9299 9299 - Drill and tap new holes that align the tamper switch to the magnet using a porta... Remark 9332 - 9241 - Relocate tamper switch or magnet to correct any misalignment, if necessary; Remark:9299 STEP: 9332 - 9241 - Relocate tamper switch or magnet to correct any misalignment, if necessary; Remark:9299
RPM Tamper Switch Alignment, Replacement, and Repair
9300 9300 - Reseal holes with RTV following tamper switch installation. Remark 9323 - 9305 - Install new tamper switch with two screws using a medium Phillips screwdriver; Remark:9300 STEP: 9323 - 9305 - Install new tamper switch with two screws using a medium Phillips screwdriver; Remark:9300
RPM Tamper Switch Alignment, Replacement, and Repair
9301 9301 - If the replacement terminal ends do not match the existing terminal ends, it may... Remark 9324 - 9306 - Determine if replacement terminal ends match existing terminal ends; Remark:9301 STEP: 9324 - 9306 - Determine if replacement terminal ends match existing terminal ends; Remark:9301
RPM Tamper Switch Alignment, Replacement, and Repair
9302 9302 - Open and close each door of the Control pillar, ensuring that the LED fault ligh... Remark 9318 - 9312 - Verify Control pillar tamper switch is operational; Remark:9302 STEP: 9318 - 9312 - Verify Control pillar tamper switch is operational; Remark:9302
RPM Tamper Switch Alignment, Replacement, and Repair
9303 9303 - Open and close each door of the Auxiliary pillar, ensuring that the LED fault li... Remark 9319 - 9313 - Verify Auxiliary pillar tamper switch is operational; Remark:9303 STEP: 9319 - 9313 - Verify Auxiliary pillar tamper switch is operational; Remark:9303
RPM Tamper Switch Alignment, Replacement, and Repair
9304 9304 - Remove two screws of tamper switch using a medium Phillips screwdriver Instruction 9322 - 9304 - Remove two screws of tamper switch using a medium Phillips screwdriver; Remark:9524 STEP: 9322 - 9304 - Remove two screws of tamper switch using a medium Phillips screwdriver; Remark:9524
RPM Tamper Switch Alignment, Replacement, and Repair
9305 9305 - Install new tamper switch with two screws using a medium Phillips screwdriver Instruction 9323 - 9305 - Install new tamper switch with two screws using a medium Phillips screwdriver; Remark:9300 STEP: 9323 - 9305 - Install new tamper switch with two screws using a medium Phillips screwdriver; Remark:9300
RPM Tamper Switch Alignment, Replacement, and Repair
9306 9306 - Determine if replacement terminal ends match existing terminal ends Instruction 9324 - 9306 - Determine if replacement terminal ends match existing terminal ends; Remark:9301 STEP: 9324 - 9306 - Determine if replacement terminal ends match existing terminal ends; Remark:9301
RPM Tamper Switch Alignment, Replacement, and Repair
9307 9307 - Remove ¼ inch (6mm) of insulation from tamper switch wire end using wire stripp... Instruction 9325 - 9307 - Remove ¼ inch (6mm) of insulation from tamper switch wire end using wire stripp...; Remark:9523 STEP: 9325 - 9307 - Remove ¼ inch (6mm) of insulation from tamper switch wire end using wire stripp...; Remark:9523
RPM Tamper Switch Alignment, Replacement, and Repair
9308 9308 - Insert tamper switch wire into terminal end and crimp using crimping tool Instruction 9326 - 9308 - Insert tamper switch wire into terminal end and crimp using crimping tool; Remark:9522 STEP: 9326 - 9308 - Insert tamper switch wire into terminal end and crimp using crimping tool; Remark:9522
RPM Tamper Switch Alignment, Replacement, and Repair
9309 9309 - Connect tamper switch to existing wiring using terminal end connectors Instruction 9327 - 9309 - Connect tamper switch to existing wiring using terminal end connectors; Remark:9521 STEP: 9327 - 9309 - Connect tamper switch to existing wiring using terminal end connectors; Remark:9521
RPM Tamper Switch Alignment, Replacement, and Repair
9310 9310 - Switch LD-260 to ON position and verify green “PWR ON” LED is lit Instruction 9321 - 9310 - Switch LD-260 to ON position and verify green “PWR ON” LED is lit; Remark:
9311 9311 - Verify Tamper Switch is Operational Instruction
9312 9312 - Verify Control pillar tamper switch is operational Instruction 9318 - 9312 - Verify Control pillar tamper switch is operational; Remark:9302 STEP: 9318 - 9312 - Verify Control pillar tamper switch is operational; Remark:9302
RPM Tamper Switch Alignment, Replacement, and Repair
9313 9313 - Verify Auxiliary pillar tamper switch is operational Instruction 9319 - 9313 - Verify Auxiliary pillar tamper switch is operational; Remark:9303 STEP: 9319 - 9313 - Verify Auxiliary pillar tamper switch is operational; Remark:9303
RPM Tamper Switch Alignment, Replacement, and Repair
9314 9314 - 7820 - Inform system operators upon completion of maintenance action; Remark: Procedure Step
9315 9315 - 7821 - Document maintenance performed, times, and results for inclusion in correctiv...; Remark: Procedure Step
9317 9317 - 321 - Document maintenance actions; Remark: Procedure Step
9318 9318 - 9312 - Verify Control pillar tamper switch is operational; Remark:9302 Procedure Step
9319 9319 - 9313 - Verify Auxiliary pillar tamper switch is operational; Remark:9303 Procedure Step
9320 9320 - 7249 - Return equipment to normal operating condition; Remark: Procedure Step
9321 9321 - 9310 - Switch LD-260 to ON position and verify green “PWR ON” LED is lit; Remark: Procedure Step
9322 9322 - 9304 - Remove two screws of tamper switch using a medium Phillips screwdriver; Remark:9524 Procedure Step
9323 9323 - 9305 - Install new tamper switch with two screws using a medium Phillips screwdriver; Remark:9300 Procedure Step
9324 9324 - 9306 - Determine if replacement terminal ends match existing terminal ends; Remark:9301 Procedure Step
9325 9325 - 9307 - Remove ¼ inch (6mm) of insulation from tamper switch wire end using wire stripp...; Remark:9523 Procedure Step