RadSeeker CS/CL Wi-Fi Status Change

Last Updated: 04/24/2025 1:42 AM

The following table lists all the components that make up the document.

Title Type Status Last Updated
Smiths Detection RadSeeker CS
Device
Published
06/27/2024 12:54 PM
4032 - 4019 - Prepare Equipment; Remark:
Procedure Step
Published
10/31/2022 10:54 AM
4019 - Prepare Equipment
Instruction
Published
04/21/2022 12:44 PM
5599 - 5598 - Obtain Service Mode password for unit; Remark:5597
Procedure Step
Published
10/31/2022 11:35 AM
5598 - Obtain Service Mode password for unit
Instruction
Published
10/31/2022 11:34 AM
5597 - Password is serial number specific. Obtain from Nuclear Smuggling Detection a...
Remark
Published
10/31/2022 11:35 AM
2348 - 2295 - Verify sufficient battery charge; Remark:2301
Procedure Step
Published
11/04/2020 2:35 PM
2295 - Verify sufficient battery charge
Instruction
Published
04/06/2021 4:43 PM
2301 - Open the battery cover to view the charge level indicator.
Remark
Published
07/23/2021 8:38 PM
2302 - Replace battery pack or charge instrument if fewer than two (2) bars are visi...
Remark
Published
07/27/2021 12:20 PM
2297 - IO RadSeeker 3 bar Battery
Remark
Published
10/19/2024 10:28 PM
4723 - 220 - Power on instrument; Remark:4721
Procedure Step
Published
07/01/2022 1:02 AM
220 - Power on instrument
Instruction
Published
04/06/2025 7:00 PM
4721 - Press and hold ENTER button until display powers on (3 to 5 ...
Remark
Published
06/29/2022 1:12 PM
2298 - IO RadSeeker Button Pad Select Button Yellow Box
Remark
Published
10/21/2024 7:26 PM
2462 - 612 - Wait for instrument to complete start-up sequence; Remark:2306
Procedure Step
Published
04/13/2025 6:49 PM
612 - Wait for instrument to complete start-up sequence
Instruction
Published
04/13/2025 6:38 PM
2306 - The instrument will automatically enter Detect mode after sy...
Remark
Published
07/23/2021 8:45 PM
5600 - 5596 - Verify computer is powered on; Remark:
Procedure Step
Published
10/31/2022 11:35 AM
5596 - Verify computer is powered on
Instruction
Published
10/31/2022 11:35 AM
5595 - 5594 - Establish Connection between Computer and RadSeeker; Remark:
Procedure Step
Published
10/31/2022 11:36 AM
5594 - Establish Connection between Computer and RadSeeker
Instruction
Published
10/31/2022 11:36 AM
3721 - 3601 - Connect instrument to computer; Remark:3607
Procedure Step
Published
09/30/2021 11:27 AM
3601 - Connect instrument to computer
Instruction
Published
09/23/2021 5:51 PM
3607 - Use USB-A to mini-USB cable provided with RadSeeker.
Remark
Published
09/23/2021 5:57 PM
3608 - IO RadSeeker Insert mini-USB
Remark
Published
09/23/2021 5:59 PM
3651 - If Detector Controller software does not start automatically, double click ic...
Remark
Published
09/28/2021 2:57 PM
3722 - 3635 - Wait for Detector Controller to open; Remark:3652
Procedure Step
Published
10/31/2022 11:05 AM
3635 - Wait for Detector Controller to open
Instruction
Published
09/28/2021 2:44 PM
3652 - Detector Controller opens automatically to the Offload Data ...
Remark
Published
09/28/2021 2:58 PM
5581 - If the computer cannot connect with the RadSeeker, refer to DET-HHD-SMD-OP04,...
Remark
Published
10/31/2022 11:04 AM
5593 - 5592 - Enter Service Mode; Remark:
Procedure Step
Published
10/31/2022 11:37 AM
5592 - Enter Service Mode
Instruction
Published
10/31/2022 11:37 AM
5648 - 5647 - Select Operations tab; Remark:5649
Procedure Step
Published
10/31/2022 12:11 PM
5647 - Select Operations tab
Instruction
Published
10/31/2022 12:11 PM
5649 - IO RadSeeker Operations Tab Controller
Remark
Published
10/31/2022 4:35 PM
5640 - 5639 - Click Advanced Control; Remark:5650
Procedure Step
Published
10/31/2022 12:12 PM
5639 - Click Advanced Control
Instruction
Published
10/31/2022 12:12 PM
5650 - IO RadSeeker Advanced Control Controller
Remark
Published
10/31/2022 4:39 PM
5641 - 5636 - Enter Service Mode password and click Login; Remark:5651
Procedure Step
Published
10/31/2022 12:14 PM
5637 - Caution : Certain changes made in Service Mode can cause critical degradation to instru...
Annotation
Published
10/31/2022 12:13 PM
5638 - Note : The Service Mode password is different than the Advanced Mode password suppli...
Annotation
Published
10/31/2022 12:14 PM
5636 - Enter Service Mode password and click Login
Instruction
Published
10/31/2022 12:13 PM
5651 - IO RadSeeker Login Password Window
Remark
Published
10/31/2022 4:38 PM
5591 - 5590 - Move Configuration File to Computer; Remark:
Procedure Step
Published
10/31/2022 11:38 AM
5590 - Move Configuration File to Computer
Instruction
Published
10/31/2022 11:38 AM
5642 - 5635 - Select File Transfer tab; Remark:5652
Procedure Step
Published
10/31/2022 12:15 PM
5635 - Select File Transfer tab
Instruction
Published
10/31/2022 12:15 PM
5652 - IO RadSeeker File Transfer Controller
Remark
Published
11/01/2022 4:50 AM
5643 - 5634 - Navigate to Control folder; Remark:5633
Procedure Step
Published
10/31/2022 12:18 PM
5634 - Navigate to Control folder
Instruction
Published
10/31/2022 12:16 PM
5633 - To locate Control folder, expand directory structure on right side of screen,...
Remark
Published
10/31/2022 12:17 PM
5644 - 5632 - Select service.xml file; Remark:5653
Procedure Step
Published
10/31/2022 12:19 PM
5632 - Select service.xml file
Instruction
Published
10/31/2022 12:18 PM
5653 - IO RadSeeker ServiceXML in NAND Controller
Remark
Published
11/01/2022 4:52 AM
5645 - 5631 - Choose a local folder on your computer; Remark:5630
Procedure Step
Published
10/31/2022 12:20 PM
5631 - Choose a local folder on your computer
Instruction
Published
10/31/2022 12:19 PM
5630 - On the left (Local) side of Detector Controller window, expand My Computer fi...
Remark
Published
10/31/2022 12:20 PM
5646 - 5629 - Initiate transfer from RadSeeker to computer; Remark:5628
Procedure Step
Published
10/31/2022 12:21 PM
5629 - Initiate transfer from RadSeeker to computer
Instruction
Published
10/31/2022 12:20 PM
5628 - Click left-pointing green arrow to transfer file from RadSeeker to computer.
Remark
Published
10/31/2022 12:21 PM
5589 - 5588 - Edit Configuration File; Remark:
Procedure Step
Published
10/31/2022 11:39 AM
5588 - Edit Configuration File
Instruction
Published
10/31/2022 11:39 AM
5624 - 5623 - Open service.xml file; Remark:5622
Procedure Step
Published
10/31/2022 11:56 AM
5623 - Open service.xml file
Instruction
Published
10/31/2022 11:55 AM
5622 - Without closing the Detector Controller software, open service.xml
Remark
Published
10/31/2022 11:56 AM
5625 - 5621 - Locate Wi-Fi parameter; Remark:5620
Procedure Step
Published
10/31/2022 11:57 AM
5621 - Locate Wi-Fi parameter
Instruction
Published
10/31/2022 11:56 AM
5620 - In the service.xml file, locate the line that reads ...
Remark
Published
10/31/2022 11:57 AM
5626 - 5618 - Edit Wi-Fi status; Remark:5617
Procedure Step
Published
10/31/2022 12:00 PM
5619 - Caution : Do not change any other settings in the service.xml file.
Annotation
Published
10/31/2022 12:02 PM
5618 - Edit Wi-Fi status
Instruction
Published
10/31/2022 11:58 AM
5617 - To disable Wi-Fi, edit line to read as follows: <ForceWifiDisable&...
Remark
Published
10/31/2022 12:00 PM
5627 - 5616 - Save file service.xml; Remark:5615
Procedure Step
Published
10/31/2022 12:01 PM
5616 - Save file service.xml
Instruction
Published
10/31/2022 12:01 PM
5615 - Click File and then click Save.
Remark
Published
10/31/2022 12:01 PM
5587 - 5586 - Transfer Edited service.xml File; Remark:
Procedure Step
Published
10/31/2022 11:39 AM
5586 - Transfer Edited service.xml File
Instruction
Published
10/31/2022 11:39 AM
5611 - 5610 - Return to Detector Controller software; Remark:
Procedure Step
Published
10/31/2022 11:47 AM
5610 - Return to Detector Controller software
Instruction
Published
10/31/2022 11:47 AM
5612 - 5609 - Select service.xml on computer; Remark:5654
Procedure Step
Published
10/31/2022 11:48 AM
5609 - Select service.xml on computer
Instruction
Published
10/31/2022 11:48 AM
5654 - IO RadSeeker ServiceXML in LOCAL Controller
Remark
Published
11/01/2022 4:54 AM
5613 - 5608 - Click green arrow to initiate transfer from computer to RadSeeker; Remark:5607
Procedure Step
Published
10/31/2022 11:50 AM
5608 - Click green arrow to initiate transfer from computer to RadSeeker
Instruction
Published
10/31/2022 11:49 AM
5607 - This will overwrite the version on the RadSeeker.
Remark
Published
10/31/2022 11:50 AM
5606 - 5602 - Close Detector Controller software; Remark:3656
Procedure Step
Published
10/31/2022 11:50 AM
5602 - Close Detector Controller software
Instruction
Published
10/31/2022 11:50 AM
3656 - IO RadSeeker Exit Detector Controller
Remark
Published
09/28/2021 3:03 PM
5585 - 5584 - Verify Wi-Fi Status; Remark:
Procedure Step
Published
10/31/2022 11:40 AM
5584 - Verify Wi-Fi Status
Instruction
Published
10/31/2022 11:40 AM
2497 - 313 - Power off instrument; Remark:2330
Procedure Step
Published
11/04/2020 5:53 PM
313 - Power off instrument
Instruction
Published
07/23/2021 2:41 PM
2330 - Press ENTER until the screen displays Shutting down
Remark
Published
07/23/2021 9:42 PM
2316 - IO RadSeeker Shutting Down
Remark
Published
11/04/2020 4:58 PM
5605 - 5604 - Confirm settings change; Remark:5603
Procedure Step
Published
10/31/2022 11:46 AM
5604 - Confirm settings change
Instruction
Published
10/31/2022 11:45 AM
5603 - Icon at the top right of the screen indicates Wi-Fi status.
Remark
Published
10/31/2022 11:46 AM
5655 - Wi-Fi disabled:
Remark
Published
11/01/2022 4:56 AM
5656 - Wi-Fi enabled:
Remark
Published
11/01/2022 4:57 AM
322 - 321 - Document maintenance actions; Remark:
Procedure Step
Published
06/17/2021 9:49 AM
321 - Document maintenance actions
Instruction
Published
04/21/2025 11:19 AM
2869 - 2585 - Document maintenance performed; Remark:2866
Procedure Step
Published
06/18/2021 5:58 PM
2585 - Document maintenance performed
Instruction
Published
07/09/2021 12:15 PM
2866 - Record observations, times, and results for the maintenance report.
Remark
Published
04/21/2025 11:39 AM
4706 - 4705 - Submit report; Remark:4864
Procedure Step
Published
06/29/2022 9:50 AM
4705 - Submit report
Instruction
Published
06/29/2022 9:50 AM
4864 - As specified by management or contractual obligations.
Remark
Published
07/28/2022 1:36 PM
Corrective Maintenance Procedure
Document Type
Published
03/02/2020 3:32 PM
minutes
Duration
Published
05/26/2022 11:41 AM
Resolve faults (frozen display or boot errors) caused by Wi-Fi network interference
Frequency
Published
10/31/2022 11:12 AM
As Needed
Frequency
Published
04/01/2020 11:36 AM
Caution
Annotation Type
Published
03/02/2020 3:24 PM
Note
Annotation Type
Published
03/02/2020 3:25 PM
Technician 2
Skill Level
Published
04/09/2020 1:17 AM
RadSeeker alternating current (AC) power cable (or charged battery)
Tools
Published
10/31/2022 11:22 AM
Mini-USB male to USB-A male cable
Tools
Published
03/19/2021 3:37 PM
Computer running Windows 7 or later operating system
Tools
Published
10/31/2022 11:22 AM
Smiths Detection Detector Controller software and drivers
Tools
Published
10/31/2022 11:24 AM
Notepad or other text editing software
Tools
Published
10/31/2022 11:14 AM
radseeker_di_battopen_2arrow_00659.jpg
படம்
Published
10/20/2023 9:31 AM
radseeker_di_battbar_000477.jpg
படம்
Published
10/18/2023 4:32 PM
radseeker_di_selectmiddle_00473.jpg
படம்
Published
10/20/2023 9:35 AM
radseeker_ui_modedetect_217cps_00467.jpg
படம்
Published
10/20/2023 10:15 AM
Laptop USB Plug-in
படம்
Published
12/24/2021 1:50 AM
RadSeeker Connector USB Insert
படம்
Published
12/24/2021 1:50 AM
Smiths Controller Screen Icon
படம்
Published
12/26/2021 2:26 AM
Smiths Controller Offload Data
படம்
Published
12/26/2021 2:26 AM
Smiths Controller Operations Tab
படம்
Published
10/31/2022 2:24 PM
Smiths Controller Advanced Control Tab
படம்
Published
10/31/2022 2:27 PM
Smiths Controller Window for Login Password
படம்
Published
10/31/2022 2:30 PM
Smiths Controller File Transfer Tab
படம்
Published
10/31/2022 2:35 PM
Smiths Controller Control Folder for service.xml
படம்
Published
10/31/2022 2:42 PM
Smiths Controller Select service.xml File
படம்
Published
10/31/2022 2:45 PM
Smiths Controller Expand My Computer Local
படம்
Published
10/31/2022 2:49 PM
Smiths Controller Green Arrow From RadSeeker
படம்
Published
10/31/2022 3:02 PM
Smiths Controller Open File Notepad
படம்
Published
10/31/2022 3:54 PM
Smiths Controller Wifi Parameter Disable
படம்
Published
10/31/2022 3:31 PM
Smiths Controller Local Documents Folder for service.xml
படம்
Published
10/31/2022 3:44 PM
Smiths Controller Green Arrow From Computer
படம்
Published
10/31/2022 3:50 PM
Smiths Controller Exit
படம்
Published
12/26/2021 2:26 AM
radseeker_ui_shut_00460.jpg
படம்
Published
10/20/2023 10:19 AM
radseeker_ui_wifidisable_status.jpg
படம்
Published
10/18/2023 4:25 PM
radseeker_ui_wifienable_status.jpg
படம்
Published
10/18/2023 4:25 PM

RadSeeker Detector Controller Installation

Last Updated: 04/24/2025 1:39 AM

The following table lists all the components that make up the document.

Title Type Status Last Updated
Smiths Detection RadSeeker CS
Device
Published
06/27/2024 12:54 PM
3688 - 3603 - Install Drivers; Remark:
Procedure Step
Published
09/29/2021 2:46 PM
3604 - Note : The instructions in the RadSeeker Detector Controller PC Software Manual will...
Annotation
Published
09/23/2021 5:53 PM
3605 - Note : This procedure was validated on a computer with Windows 7. The software shoul...
Annotation
Published
09/23/2021 5:53 PM
3603 - Install Drivers
Instruction
Published
09/23/2021 5:51 PM
3689 - 3602 - Insert Detector Controller disk into computer; Remark:3606
Procedure Step
Published
09/29/2021 2:47 PM
3602 - Insert Detector Controller disk into computer
Instruction
Published
09/23/2021 5:51 PM
3606 - For computers with no Disk drive, copy CD contents to a USB drive.
Remark
Published
09/23/2021 5:57 PM
3690 - 3601 - Connect instrument to computer; Remark:5972
Procedure Step
Published
09/29/2021 2:48 PM
3601 - Connect instrument to computer
Instruction
Published
09/23/2021 5:51 PM
5972 - IO RadSeeker Connect USB to Computer and RadSeeker Connector USB Insert
Remark
Published
11/15/2022 11:53 AM
3691 - 3600 - Open Device Manager; Remark:3612
Procedure Step
Published
09/29/2021 2:49 PM
3600 - Open Device Manager
Instruction
Published
09/23/2021 5:50 PM
3612 - Type Device Manager in the Windows start menu.
Remark
Published
09/27/2021 1:42 PM
3692 - 3599 - Find RadSeeker Serial USB; Remark:3613
Procedure Step
Published
09/29/2021 2:50 PM
3599 - Find RadSeeker Serial USB
Instruction
Published
09/23/2021 5:50 PM
3613 - IO RadSeeker DeviceMgr Other USB
Remark
Published
09/27/2021 1:43 PM
3693 - 3598 - Right click on RadSeeker Serial USB and select Updat...; Remark:3614
Procedure Step
Published
09/29/2021 2:51 PM
3598 - Right click on RadSeeker Serial USB and select Updat...
Instruction
Published
09/23/2021 5:50 PM
3614 - RadSeeker Serial USB will be listed under Other devices and might have a yell...
Remark
Published
09/27/2021 1:44 PM
3694 - 3597 - Click Browse my computer for driver software; Remark:3615
Procedure Step
Published
09/29/2021 2:52 PM
3597 - Click Browse my computer for driver software
Instruction
Published
09/23/2021 5:49 PM
3615 - IO RadSeeker DriverUpdate Browse Option
Remark
Published
09/27/2021 1:46 PM
3695 - 3596 - Click Browse; Remark:3616
Procedure Step
Published
09/29/2021 2:52 PM
3596 - Click Browse
Instruction
Published
09/23/2021 5:48 PM
3616 - IO RadSeeker DriverUpdate Browse Button
Remark
Published
09/27/2021 1:47 PM
3696 - 3595 - Select RadSeeker disk and click OK; Remark:3617
Procedure Step
Published
09/29/2021 2:54 PM
3595 - Select RadSeeker disk and click OK
Instruction
Published
09/23/2021 5:47 PM
3617 - Select the Disk drive or the USB drive where the RadSeeker contents are store...
Remark
Published
09/27/2021 1:48 PM
3697 - 3594 - Click Next; Remark:3618
Procedure Step
Published
09/29/2021 2:55 PM
3594 - Click Next
Instruction
Published
09/23/2021 5:47 PM
3618 - IO RadSeeker DriverUpdate Next Button
Remark
Published
09/27/2021 1:49 PM
3698 - 3593 - Click Install if security popup appears; Remark:3619
Procedure Step
Published
09/29/2021 2:55 PM
3593 - Click Install if security popup appears
Instruction
Published
09/23/2021 5:47 PM
3619 - IO RadSeeker DriverUpdate Install Button
Remark
Published
09/27/2021 1:51 PM
3699 - 3592 - Click Close when drivers finish installing; Remark:3620
Procedure Step
Published
09/29/2021 2:56 PM
3592 - Click Close when drivers finish installing
Instruction
Published
09/23/2021 5:46 PM
3620 - IO RadSeeker DriverUpdate Close Button
Remark
Published
09/27/2021 1:52 PM
3621 - In the Device Manager, Smiths Detection RadSeeker Serial is ...
Remark
Published
09/27/2021 1:54 PM
3700 - 3591 - Disconnect instrument from computer; Remark:3622
Procedure Step
Published
09/29/2021 2:58 PM
3591 - Disconnect instrument from computer
Instruction
Published
09/23/2021 5:45 PM
3622 - IO RadSeeker Remove mini-USB
Remark
Published
09/27/2021 1:56 PM
3701 - 3590 - Install Detector Controller Application; Remark:
Procedure Step
Published
09/29/2021 2:58 PM
3590 - Install Detector Controller Application
Instruction
Published
09/23/2021 5:45 PM
3702 - 3589 - Open Media Manager from Detector Controller disk; Remark:3623
Procedure Step
Published
09/29/2021 3:02 PM
3589 - Open Media Manager from Detector Controller disk
Instruction
Published
09/23/2021 5:44 PM
3623 - If the Media Manager did not open automatically when the disk was inserted, b...
Remark
Published
09/29/2021 3:01 PM
3718 - 3588 - Click Install Detector Controller; Remark:3624
Procedure Step
Published
09/30/2021 10:29 AM
3588 - Click Install Detector Controller
Instruction
Published
09/23/2021 5:44 PM
3624 - IO RadSeeker Controller Install
Remark
Published
09/27/2021 2:46 PM
3703 - 3587 - Follow Setup Wizard prompts; Remark:3625
Procedure Step
Published
09/29/2021 3:03 PM
3587 - Follow Setup Wizard prompts
Instruction
Published
09/23/2021 5:44 PM
3625 - IO RadSeeker Controller Welcome Setup
Remark
Published
09/27/2021 2:47 PM
3704 - 3586 - Click Finish once installation is complete; Remark:3626
Procedure Step
Published
09/29/2021 3:03 PM
3586 - Click Finish once installation is complete
Instruction
Published
09/23/2021 5:43 PM
3626 - IO RadSeeker Controller Complete Setup
Remark
Published
09/27/2021 2:48 PM
3705 - 3585 - Verify Detector Controller application was successfully installed; Remark:3627
Procedure Step
Published
09/29/2021 3:05 PM
3585 - Verify Detector Controller application was successfully installed
Instruction
Published
09/23/2021 5:43 PM
3627 - The Detector Controller icon should appear on the desktop.
Remark
Published
09/27/2021 2:49 PM
3706 - 3584 - Install Connection Manager Application; Remark:
Procedure Step
Published
09/29/2021 3:05 PM
3584 - Install Connection Manager Application
Instruction
Published
09/23/2021 5:42 PM
3707 - 3583 - Click Install Connection Manager in Media Manager window...; Remark:3628
Procedure Step
Published
09/29/2021 3:06 PM
3583 - Click Install Connection Manager in Media Manager window...
Instruction
Published
09/23/2021 5:41 PM
3628 - IO RadSeeker Connection Install
Remark
Published
09/27/2021 2:51 PM
3708 - 3582 - Follow Setup Wizard prompts; Remark:3629
Procedure Step
Published
09/29/2021 3:07 PM
3582 - Follow Setup Wizard prompts
Instruction
Published
09/23/2021 5:41 PM
3629 - IO RadSeeker Connection Welcome Setup
Remark
Published
09/27/2021 2:52 PM
3709 - 3581 - Click Finish to return to Media Manager window; Remark:3630
Procedure Step
Published
09/29/2021 3:08 PM
3581 - Click Finish to return to Media Manager window
Instruction
Published
09/23/2021 5:40 PM
3630 - IO RadSeeker Connection Finish Setup
Remark
Published
09/27/2021 2:53 PM
3710 - 3580 - Verify Connection Manager application was successfully installed; Remark:3631
Procedure Step
Published
09/29/2021 3:10 PM
3580 - Verify Connection Manager application was successfully installed
Instruction
Published
09/23/2021 5:40 PM
3631 - The Connection Manager icon will appear in the system tray following successf...
Remark
Published
09/27/2021 2:54 PM
3711 - 3579 - Close Media Manager program and remove disk from computer; Remark:3632
Procedure Step
Published
09/29/2021 3:11 PM
3579 - Close Media Manager program and remove disk from computer
Instruction
Published
09/23/2021 5:39 PM
3632 - IO RadSeeker Controller Media Mgr Close
Remark
Published
09/27/2021 2:56 PM
3712 - 3578 - Verify RadSeeker Connection; Remark:
Procedure Step
Published
09/29/2021 3:11 PM
3578 - Verify RadSeeker Connection
Instruction
Published
09/23/2021 5:39 PM
3713 - 3577 - Connect instrument to computer again; Remark:3608
Procedure Step
Published
09/29/2021 3:12 PM
3577 - Connect instrument to computer again
Instruction
Published
09/23/2021 5:38 PM
3608 - IO RadSeeker Insert mini-USB
Remark
Published
09/23/2021 5:59 PM
3714 - 3576 - Wait for Detector Controller application to open; Remark:3633
Procedure Step
Published
09/29/2021 3:13 PM
3576 - Wait for Detector Controller application to open
Instruction
Published
09/23/2021 5:36 PM
3633 - If drivers and applications were successfully installed, the Detector Control...
Remark
Published
09/27/2021 2:58 PM
3634 - If Detector Controller software does not start automatically, double click th...
Remark
Published
09/27/2021 2:58 PM
253 - 242 - Document and report any unresolved problems; Remark:
Procedure Step
Published
06/22/2021 10:23 AM
242 - Document and report any unresolved problems
Instruction
Published
04/21/2025 11:45 AM
Operator Procedure
Document Type
Published
03/02/2020 3:31 PM
Note
Annotation Type
Published
03/02/2020 3:25 PM
Detector Controller disk
Tools
Published
09/30/2021 11:17 AM
Mini-USB male to USB-A male cable
Tools
Published
03/19/2021 3:37 PM
Computer
Tools
Published
05/09/2020 3:05 PM
radseeker_di_connect_usb_to_computer.jpg
படம்
Published
10/10/2023 12:30 AM
RadSeeker Connector USB Insert
படம்
Published
12/24/2021 1:50 AM
Smiths Controller Windows Device Mgr
படம்
Published
12/30/2021 1:50 AM
Smiths Controller Device Other Serial USB
படம்
Published
12/30/2021 1:50 AM
Smiths Controller Device Update Driver USB
படம்
Published
12/30/2021 1:50 AM
Smiths Controller Device Browse Computer
படம்
Published
12/30/2021 1:50 AM
Smiths Controller Device Browse Button
படம்
Published
12/30/2021 1:50 AM
Smiths Controller Device as Drive
படம்
Published
12/30/2021 1:50 AM
Smiths Controller Device Driver Next
படம்
Published
12/30/2021 1:50 AM
Smiths Controller Device Driver Install
படம்
Published
12/30/2021 1:50 AM
Smiths Controller Device Driver Close
படம்
Published
12/30/2021 1:50 AM
Smiths Controller Device Driver Port ID
படம்
Published
12/30/2021 1:50 AM
RadSeeker Connector USB Remove
படம்
Published
12/24/2021 1:50 AM
Smiths Controller Device Media Manager
படம்
Published
12/30/2021 1:50 AM
Smiths Controller Device App Install
படம்
Published
12/30/2021 1:50 AM
Smiths Controller Welcome
படம்
Published
12/30/2021 1:50 AM
Smiths Controller Finish
படம்
Published
12/30/2021 1:50 AM
Smiths Controller Screen Icon
படம்
Published
12/26/2021 2:26 AM
Smiths Connection Mgr Install
படம்
Published
12/30/2021 1:50 AM
detectorcon_ui_wizardwelcome2_00696.png
படம்
Published
12/30/2021 1:50 AM
Smiths Connection Mgr Finish
படம்
Published
12/30/2021 1:50 AM
Smiths Connection Mgr Screen Icon Tray
படம்
Published
12/26/2021 2:26 AM
Smiths Controller Device App Close
படம்
Published
12/30/2021 1:50 AM
Smiths Controller Device App Opening Screen
படம்
Published
12/30/2021 1:50 AM

RadSeeker Upload and Attach with Schneider

Last Updated: 04/24/2025 1:39 AM

The following table lists all the components that make up the document.

Title Type Status Last Updated
Smiths Detection RadSeeker CS
Device
Published
06/27/2024 12:54 PM
3719 - 3687 - Upload Spectra; Remark:
Procedure Step
Published
09/30/2021 11:22 AM
3687 - Upload Spectra
Instruction
Published
09/29/2021 9:29 AM
3720 - 220 - Power on instrument; Remark:2303
Procedure Step
Published
09/30/2021 11:24 AM
3666 - Note : Smiths Detection Connection Manager and Detector Controller must be installed...
Annotation
Published
09/28/2021 3:25 PM
220 - Power on instrument
Instruction
Published
04/06/2025 7:00 PM
2303 - Press and hold ENTER button until display powers on (3 to 5 ...
Remark
Published
07/23/2021 8:41 PM
2298 - IO RadSeeker Button Pad Select Button Yellow Box
Remark
Published
10/21/2024 7:26 PM
3721 - 3601 - Connect instrument to computer; Remark:3607
Procedure Step
Published
09/30/2021 11:27 AM
3601 - Connect instrument to computer
Instruction
Published
09/23/2021 5:51 PM
3607 - Use USB-A to mini-USB cable provided with RadSeeker.
Remark
Published
09/23/2021 5:57 PM
3608 - IO RadSeeker Insert mini-USB
Remark
Published
09/23/2021 5:59 PM
3651 - If Detector Controller software does not start automatically, double click ic...
Remark
Published
09/28/2021 2:57 PM
3722 - 3635 - Wait for Detector Controller to open; Remark:3652
Procedure Step
Published
10/31/2022 11:05 AM
3635 - Wait for Detector Controller to open
Instruction
Published
09/28/2021 2:44 PM
3652 - Detector Controller opens automatically to the Offload Data ...
Remark
Published
09/28/2021 2:58 PM
5581 - If the computer cannot connect with the RadSeeker, refer to DET-HHD-SMD-OP04,...
Remark
Published
10/31/2022 11:04 AM
3723 - 3636 - Select files to transfer; Remark:3653
Procedure Step
Published
09/30/2021 11:29 AM
3667 - Note : RadSeeker stores three files for every identification measurement; it is only...
Annotation
Published
09/28/2021 3:26 PM
3668 - Note : Delete spectra from RadSeeker after upload by selecting Delete downloaded dat...
Annotation
Published
09/28/2021 3:26 PM
3636 - Select files to transfer
Instruction
Published
09/28/2021 2:45 PM
3653 - Under Download, select which files to transfer to computer. ...
Remark
Published
09/28/2021 3:00 PM
3724 - 3637 - Select location to store files; Remark:3654
Procedure Step
Published
09/30/2021 11:30 AM
3637 - Select location to store files
Instruction
Published
09/28/2021 2:45 PM
3654 - Select the location to save the files to by clicking Browse....
Remark
Published
09/28/2021 3:01 PM
3725 - 3638 - Click Start Offloading; Remark:3655
Procedure Step
Published
09/30/2021 11:31 AM
3638 - Click Start Offloading
Instruction
Published
09/28/2021 2:45 PM
3655 - The Download Status will display Offloaded when the file upl...
Remark
Published
09/28/2021 3:02 PM
3726 - 3639 - Exit software; Remark:3656
Procedure Step
Published
09/30/2021 11:32 AM
3639 - Exit software
Instruction
Published
09/28/2021 2:46 PM
3656 - IO RadSeeker Exit Detector Controller
Remark
Published
09/28/2021 3:03 PM
3727 - 3641 - Attach Spectra; Remark:
Procedure Step
Published
10/02/2022 2:38 PM
3641 - Attach Spectra
Instruction
Published
10/02/2022 2:03 PM
3738 - 3670 - Click on Alarms from Schneider CAS home screen; Remark:3677
Procedure Step
Published
09/30/2021 1:24 PM
3670 - Click on Alarms from Schneider CAS home screen
Instruction
Published
09/28/2021 3:34 PM
3677 - IO SchCAS Site Map Alarms Red Box
Remark
Published
09/28/2021 3:41 PM
3739 - 3671 - Click on magnifying glass next to event; Remark:3678
Procedure Step
Published
09/30/2021 1:24 PM
3671 - Click on magnifying glass next to event
Instruction
Published
09/28/2021 3:34 PM
3678 - IO SchCAS Event List Magnifier Box
Remark
Published
09/28/2021 3:43 PM
3740 - 3672 - Select Display Alarm Details Popup; Remark:3679
Procedure Step
Published
09/30/2021 1:25 PM
3672 - Select Display Alarm Details Popup
Instruction
Published
09/28/2021 3:35 PM
3679 - IO SchCAS Event List Menu Display Details
Remark
Published
09/28/2021 3:44 PM
3741 - 3673 - Select Files tab; Remark:3680
Procedure Step
Published
09/30/2021 1:26 PM
3673 - Select Files tab
Instruction
Published
09/28/2021 3:35 PM
3680 - IO SchCAS Event Details Files tab
Remark
Published
09/28/2021 3:45 PM
3742 - 3674 - Click Attach File; Remark:3681
Procedure Step
Published
09/30/2021 1:26 PM
3674 - Click Attach File
Instruction
Published
09/28/2021 3:36 PM
3681 - IO SchCAS Event Details Files Attach File
Remark
Published
09/28/2021 3:46 PM
3743 - 3675 - Click Save/Exit; Remark:3682
Procedure Step
Published
09/30/2021 1:27 PM
3675 - Click Save/Exit
Instruction
Published
09/28/2021 3:37 PM
3682 - Locate spectral file previously saved. Select the N42.N42 file (ANSI format)....
Remark
Published
09/28/2021 3:48 PM
3744 - 3650 - Click OK; Remark:3683
Procedure Step
Published
09/30/2021 1:28 PM
3650 - Click OK
Instruction
Published
09/28/2021 2:54 PM
3683 - IO SchCAS Event File Operation OK
Remark
Published
09/28/2021 3:49 PM
3745 - 3649 - Type a comment; Remark:3684
Procedure Step
Published
09/30/2021 1:28 PM
3649 - Type a comment
Instruction
Published
09/28/2021 2:54 PM
3684 - Click on the “Details” tab then type a comment about the instrument used ...
Remark
Published
09/28/2021 3:50 PM
3746 - 3675 - Click Save/Exit; Remark:3685
Procedure Step
Published
09/30/2021 1:29 PM
3685 - IO SchCAS Event Details Save tab
Remark
Published
09/28/2021 3:51 PM
3747 - 3676 - Verify spectrum was attached; Remark:3686
Procedure Step
Published
09/30/2021 1:29 PM
3676 - Verify spectrum was attached
Instruction
Published
09/28/2021 3:38 PM
3686 - The event will have a check mark in the paper clip column.
Remark
Published
09/28/2021 3:51 PM
253 - 242 - Document and report any unresolved problems; Remark:
Procedure Step
Published
06/22/2021 10:23 AM
242 - Document and report any unresolved problems
Instruction
Published
04/21/2025 11:45 AM
Operator Procedure
Document Type
Published
03/02/2020 3:31 PM
Note
Annotation Type
Published
03/02/2020 3:25 PM
Mini-USB male to USB-A male cable
Tools
Published
03/19/2021 3:37 PM
radseeker_di_selectmiddle_00473.jpg
படம்
Published
10/20/2023 9:35 AM
Laptop USB Plug-in
படம்
Published
12/24/2021 1:50 AM
RadSeeker Connector USB Insert
படம்
Published
12/24/2021 1:50 AM
Smiths Controller Screen Icon
படம்
Published
12/26/2021 2:26 AM
Smiths Controller Offload Data
படம்
Published
12/26/2021 2:26 AM
Smiths Controller Download Menu
படம்
Published
12/26/2021 2:26 AM
Smiths Controller Location Download
படம்
Published
12/26/2021 2:26 AM
Smiths Controller Status Start Offload
படம்
Published
12/26/2021 2:26 AM
Smiths Controller Exit
படம்
Published
12/26/2021 2:26 AM
Schneider Event Alarms Button
படம்
Published
12/31/2021 1:49 AM
Schneider Event Alarm Summary Magnify
படம்
Published
12/31/2021 1:49 AM
Schneider Event Menu Display Details
படம்
Published
12/31/2021 1:49 AM
Schneider Event Files Tab
படம்
Published
12/31/2021 1:49 AM
Schneider Event Attach File Tab
படம்
Published
12/31/2021 1:49 AM
Schneider Event Files Open Spectrum
படம்
Published
12/31/2021 1:49 AM
Schneider Event File OK Attach Button
படம்
Published
12/31/2021 1:49 AM
Schneider Event File Details Comment
படம்
Published
12/31/2021 1:49 AM
Schneider Event Alarms Exit
படம்
Published
12/31/2021 1:49 AM
Schneider Event Alarm Attachment Icon
படம்
Published
12/31/2021 1:49 AM

RadSeeker Upload and Attach with RAVEN

Last Updated: 04/24/2025 1:39 AM

The following table lists all the components that make up the document.

Title Type Status Last Updated
Smiths Detection RadSeeker CS
Device
Published
06/27/2024 12:54 PM
3719 - 3687 - Upload Spectra; Remark:
Procedure Step
Published
09/30/2021 11:22 AM
3687 - Upload Spectra
Instruction
Published
09/29/2021 9:29 AM
3720 - 220 - Power on instrument; Remark:2303
Procedure Step
Published
09/30/2021 11:24 AM
3666 - Note : Smiths Detection Connection Manager and Detector Controller must be installed...
Annotation
Published
09/28/2021 3:25 PM
220 - Power on instrument
Instruction
Published
04/06/2025 7:00 PM
2303 - Press and hold ENTER button until display powers on (3 to 5 ...
Remark
Published
07/23/2021 8:41 PM
2298 - IO RadSeeker Button Pad Select Button Yellow Box
Remark
Published
10/21/2024 7:26 PM
3721 - 3601 - Connect instrument to computer; Remark:3607
Procedure Step
Published
09/30/2021 11:27 AM
3601 - Connect instrument to computer
Instruction
Published
09/23/2021 5:51 PM
3607 - Use USB-A to mini-USB cable provided with RadSeeker.
Remark
Published
09/23/2021 5:57 PM
3608 - IO RadSeeker Insert mini-USB
Remark
Published
09/23/2021 5:59 PM
3651 - If Detector Controller software does not start automatically, double click ic...
Remark
Published
09/28/2021 2:57 PM
3722 - 3635 - Wait for Detector Controller to open; Remark:3652
Procedure Step
Published
10/31/2022 11:05 AM
3635 - Wait for Detector Controller to open
Instruction
Published
09/28/2021 2:44 PM
3652 - Detector Controller opens automatically to the Offload Data ...
Remark
Published
09/28/2021 2:58 PM
5581 - If the computer cannot connect with the RadSeeker, refer to DET-HHD-SMD-OP04,...
Remark
Published
10/31/2022 11:04 AM
3723 - 3636 - Select files to transfer; Remark:3653
Procedure Step
Published
09/30/2021 11:29 AM
3667 - Note : RadSeeker stores three files for every identification measurement; it is only...
Annotation
Published
09/28/2021 3:26 PM
3668 - Note : Delete spectra from RadSeeker after upload by selecting Delete downloaded dat...
Annotation
Published
09/28/2021 3:26 PM
3636 - Select files to transfer
Instruction
Published
09/28/2021 2:45 PM
3653 - Under Download, select which files to transfer to computer. ...
Remark
Published
09/28/2021 3:00 PM
3724 - 3637 - Select location to store files; Remark:3654
Procedure Step
Published
09/30/2021 11:30 AM
3637 - Select location to store files
Instruction
Published
09/28/2021 2:45 PM
3654 - Select the location to save the files to by clicking Browse....
Remark
Published
09/28/2021 3:01 PM
3725 - 3638 - Click Start Offloading; Remark:3655
Procedure Step
Published
09/30/2021 11:31 AM
3638 - Click Start Offloading
Instruction
Published
09/28/2021 2:45 PM
3655 - The Download Status will display Offloaded when the file upl...
Remark
Published
09/28/2021 3:02 PM
3726 - 3639 - Exit software; Remark:3656
Procedure Step
Published
09/30/2021 11:32 AM
3639 - Exit software
Instruction
Published
09/28/2021 2:46 PM
3656 - IO RadSeeker Exit Detector Controller
Remark
Published
09/28/2021 3:03 PM
3700 - 3591 - Disconnect instrument from computer; Remark:3622
Procedure Step
Published
09/29/2021 2:58 PM
3591 - Disconnect instrument from computer
Instruction
Published
09/23/2021 5:45 PM
3622 - IO RadSeeker Remove mini-USB
Remark
Published
09/27/2021 1:56 PM
3727 - 3641 - Attach Spectra; Remark:
Procedure Step
Published
10/02/2022 2:38 PM
3641 - Attach Spectra
Instruction
Published
10/02/2022 2:03 PM
3728 - 3640 - Open RAVEN Event Log; Remark:3657
Procedure Step
Published
10/02/2022 2:37 PM
3640 - Open RAVEN Event Log
Instruction
Published
10/02/2022 2:02 PM
3657 - IO RAVEN Event Log Tab
Remark
Published
09/28/2021 3:11 PM
3729 - 3642 - Click on alarm event to attach spectra; Remark:3658
Procedure Step
Published
10/02/2022 2:37 PM
3642 - Click on alarm event to attach spectra
Instruction
Published
10/02/2022 2:02 PM
3658 - IO RAVEN 1st Priority Alarm Event Red Box
Remark
Published
09/28/2021 3:13 PM
3730 - 3643 - Click Attach RIID; Remark:3659
Procedure Step
Published
10/02/2022 2:37 PM
3643 - Click Attach RIID
Instruction
Published
10/02/2022 2:01 PM
3659 - IO RAVEN Event Details Profile Attach RIID Red
Remark
Published
09/28/2021 3:15 PM
3731 - 3644 - Click Import File; Remark:3660
Procedure Step
Published
09/30/2021 11:36 AM
3669 - Note : RadSeeker is not currently available in the Riid Type dropdo...
Annotation
Published
09/28/2021 3:27 PM
3644 - Click Import File
Instruction
Published
10/02/2022 1:56 PM
3660 - IO RAVEN Dialog RIID Import File
Remark
Published
09/28/2021 3:16 PM
3732 - 3645 - Open spectrum; Remark:3661
Procedure Step
Published
09/30/2021 11:37 AM
3645 - Open spectrum
Instruction
Published
09/28/2021 2:51 PM
3661 - Locate spectral file previously saved. Select the N42.N42 file (ANSI format)....
Remark
Published
09/28/2021 3:18 PM
3733 - 3646 - Click OK to close Dialog window; Remark:3662
Procedure Step
Published
10/02/2022 2:35 PM
3646 - Click OK to close Dialog window
Instruction
Published
10/02/2022 1:52 PM
3662 - IO RAVEN Dialog OK to close
Remark
Published
09/28/2021 3:19 PM
3734 - 3647 - Click RIID Data tab to verify attachment; Remark:3663
Procedure Step
Published
10/02/2022 2:34 PM
3647 - Click RIID Data tab to verify attachment
Instruction
Published
10/02/2022 2:06 PM
3663 - The attached file(s) will be listed under Riid Scans attached to this...
Remark
Published
10/02/2022 2:10 PM
3735 - 3648 - Click Enter Comment; Remark:3664
Procedure Step
Published
09/30/2021 11:39 AM
3648 - Click Enter Comment
Instruction
Published
09/28/2021 2:53 PM
3664 - IO RAVEN Event Enter Comment
Remark
Published
09/28/2021 3:21 PM
3736 - 3649 - Type a comment; Remark:3665
Procedure Step
Published
09/30/2021 11:40 AM
3649 - Type a comment
Instruction
Published
09/28/2021 2:54 PM
3665 - The comment should indicate that a RadSeeker was used to perform identificati...
Remark
Published
09/28/2021 3:22 PM
3737 - 3650 - Click OK; Remark:
Procedure Step
Published
09/30/2021 11:41 AM
3650 - Click OK
Instruction
Published
09/28/2021 2:54 PM
253 - 242 - Document and report any unresolved problems; Remark:
Procedure Step
Published
06/22/2021 10:23 AM
242 - Document and report any unresolved problems
Instruction
Published
04/21/2025 11:45 AM
Operator Procedure
Document Type
Published
03/02/2020 3:31 PM
Note
Annotation Type
Published
03/02/2020 3:25 PM
Mini-USB male to USB-A male cable
Tools
Published
03/19/2021 3:37 PM
radseeker_di_selectmiddle_00473.jpg
படம்
Published
10/20/2023 9:35 AM
Laptop USB Plug-in
படம்
Published
12/24/2021 1:50 AM
RadSeeker Connector USB Insert
படம்
Published
12/24/2021 1:50 AM
Smiths Controller Screen Icon
படம்
Published
12/26/2021 2:26 AM
Smiths Controller Offload Data
படம்
Published
12/26/2021 2:26 AM
Smiths Controller Download Menu
படம்
Published
12/26/2021 2:26 AM
Smiths Controller Location Download
படம்
Published
12/26/2021 2:26 AM
Smiths Controller Status Start Offload
படம்
Published
12/26/2021 2:26 AM
Smiths Controller Exit
படம்
Published
12/26/2021 2:26 AM
RadSeeker Connector USB Remove
படம்
Published
12/24/2021 1:50 AM
RAVEN Event Log tab
படம்
Published
12/31/2021 1:49 AM
RAVEN Event Log Alarm Selection
படம்
Published
12/31/2021 1:49 AM
RAVEN Event Attach RIID Button
படம்
Published
12/31/2021 1:49 AM
RAVEN Event Import File Button
படம்
Published
12/31/2021 1:49 AM
RAVEN Event Spectrum File Open
படம்
Published
12/31/2021 1:49 AM
RAVEN Event Dialog OK Button
படம்
Published
12/31/2021 1:49 AM
RAVEN Event Verify RIID Data
படம்
Published
12/31/2021 1:49 AM
RAVEN Event Enter Comment Button
படம்
Published
12/31/2021 1:49 AM
RAVEN Event Comment Text Field
படம்
Published
12/31/2021 1:49 AM

PRM-470 Gamma Alignment

Last Updated: 04/24/2025 1:34 AM

The following table lists all the components that make up the document.

Title Type Status Last Updated
247 - 257 - Prepare instrument; Remark:
Procedure Step
Published
04/11/2025 9:08 PM
257 - Prepare instrument
Instruction
Published
04/11/2025 9:07 PM
2548 - 205 - Disconnect charger; Remark:2547
Procedure Step
Published
08/02/2021 12:46 PM
205 - Disconnect charger
Instruction
Published
07/23/2021 2:42 PM
2547 - IO PRM-470 Remove Charger Cable
Remark
Published
11/02/2024 3:10 PM
2633 - 220 - Power on instrument; Remark:2545
Procedure Step
Published
08/12/2021 12:19 PM
220 - Power on instrument
Instruction
Published
04/06/2025 7:00 PM
2545 - IO PRM-470 Power Button Red Box
Remark
Published
10/29/2024 9:30 PM
261 - 65 - Loosen four (4) cover screws; Remark:264
Procedure Step
Published
08/12/2021 7:25 AM
65 - Loosen four (4) cover screws
Instruction
Published
07/22/2021 12:38 PM
264 - Use a medium Phillips (PH2) screwdriver. Screws do not need to be completely ...
Remark
Published
07/20/2021 3:59 PM
2642 - 262 - Remove instrument cover; Remark:2631
Procedure Step
Published
08/23/2021 11:44 AM
2634 - Warning : Do not touch circuit board components as there are high voltage energized tes...
Annotation
Published
08/23/2021 11:27 AM
262 - Remove instrument cover
Instruction
Published
07/20/2021 3:35 PM
2631 - IO PRM-470 Cover Open Action
Remark
Published
11/02/2024 3:12 PM
2643 - 2551 - Connect Multichannel Analyzer (MCA); Remark:
Procedure Step
Published
08/23/2021 11:44 AM
2551 - Connect Multichannel Analyzer (MCA)
Instruction
Published
08/03/2021 2:13 PM
2644 - 2552 - Connect MCA to computer; Remark:2630
Procedure Step
Published
08/23/2021 11:44 AM
2552 - Connect MCA to computer
Instruction
Published
08/03/2021 2:15 PM
2630 - Use provided Mini-USB [universal serial bus] to USB cable.
Remark
Published
08/23/2021 11:29 AM
2645 - 2553 - Attach test leads to MCA; Remark:2629
Procedure Step
Published
08/23/2021 11:37 AM
2553 - Attach test leads to MCA
Instruction
Published
08/03/2021 2:15 PM
2629 - Connect to the SIGNAL input.
Remark
Published
08/23/2021 11:38 AM
2646 - 2554 - Collect pre-alignment Spectra; Remark:
Procedure Step
Published
08/23/2021 11:45 AM
2554 - Collect pre-alignment Spectra
Instruction
Published
08/03/2021 2:16 PM
2647 - 2555 - Start Amptek software; Remark:2627
Procedure Step
Published
08/23/2021 12:04 PM
2555 - Start Amptek software
Instruction
Published
08/03/2021 2:17 PM
2627 - IO Amptek Icon DppMCA
Remark
Published
11/02/2024 3:13 PM
2648 - 2556 - Verify MCA settings; Remark:2626
Procedure Step
Published
08/23/2021 11:40 AM
2556 - Verify MCA settings
Instruction
Published
08/23/2021 11:39 AM
2626 - Settings should match the image below.
Remark
Published
08/23/2021 11:39 AM
2649 - 2557 - Place Cs-137 source on gamma detector; Remark:2625
Procedure Step
Published
08/23/2021 11:46 AM
2557 - Place Cs-137 source on gamma detector
Instruction
Published
08/11/2021 3:25 PM
2625 - Center the source on the detector.
Remark
Published
08/11/2021 3:27 PM
2650 - 2558 - Connect leads to stage 1 test points; Remark:2624
Procedure Step
Published
08/23/2021 11:46 AM
2558 - Connect leads to stage 1 test points
Instruction
Published
08/11/2021 3:30 PM
2624 - Black test lead connects to TP20. Red test lead connects to TP1.
Remark
Published
08/11/2021 3:59 PM
2651 - 2559 - Collect stage 1 spectrum; Remark:2622
Procedure Step
Published
08/23/2021 11:47 AM
2635 - Standard : At least 2,000 counts should be recorded on the peak channel.
Annotation
Published
10/04/2022 11:15 AM
2636 - Note : Hot keys for DppMCA software: “A” will clear spectrum and restart acquisi...
Annotation
Published
10/04/2022 11:13 AM
2559 - Collect stage 1 spectrum
Instruction
Published
08/11/2021 3:30 PM
2622 - The traffic light icon will start/stop data acquisition.
Remark
Published
08/11/2021 4:00 PM
2623 - Placing the cursor at the peak location will aid in monitoring the counts in ...
Remark
Published
08/11/2021 4:01 PM
2652 - 2560 - Save stage 1 spectrum; Remark:2620
Procedure Step
Published
08/23/2021 11:47 AM
2637 - Standard : Use the following file naming convention: CO_SITE_MO_SN_STG_PP CO =...
Annotation
Published
08/23/2021 11:50 AM
2560 - Save stage 1 spectrum
Instruction
Published
08/11/2021 3:31 PM
2620 - IO Amptek Save File in DppMCA
Remark
Published
11/02/2024 3:14 PM
2621 - Use the correct file naming convention. Example: US_Richland_CG_102...
Remark
Published
08/11/2021 4:03 PM
2653 - 2561 - Connect leads to stage 2 test point; Remark:2619
Procedure Step
Published
08/23/2021 11:51 AM
2561 - Connect leads to stage 2 test point
Instruction
Published
08/11/2021 3:32 PM
2619 - Red test lead connects to TP2.
Remark
Published
08/11/2021 4:03 PM
2654 - 2562 - Collect stage 2 spectrum; Remark:2617
Procedure Step
Published
08/23/2021 11:52 AM
2562 - Collect stage 2 spectrum
Instruction
Published
08/11/2021 3:33 PM
2617 - Start data collection.
Remark
Published
08/11/2021 4:04 PM
2618 - Placing the cursor at the peak location will aid in monitoring the counts in ...
Remark
Published
08/11/2021 4:05 PM
2655 - 2563 - Save stage 2 spectrum; Remark:2616
Procedure Step
Published
08/23/2021 11:52 AM
2563 - Save stage 2 spectrum
Instruction
Published
08/11/2021 3:38 PM
2616 - Use the correct file naming convention. Example: US_Richland_CG_102...
Remark
Published
08/11/2021 4:06 PM
2656 - 2564 - Measure pre-alignment high voltage; Remark:
Procedure Step
Published
05/03/2022 12:00 PM
2564 - Measure pre-alignment high voltage
Instruction
Published
05/03/2022 12:00 PM
2657 - 2565 - Connect HV probe to DMM; Remark:2614
Procedure Step
Published
08/23/2021 11:53 AM
2565 - Connect HV probe to DMM
Instruction
Published
08/11/2021 3:41 PM
2614 - Use Fluke 80K-40 high voltage (HV) probe and Fluke 179 DMM.
Remark
Published
08/11/2021 4:06 PM
2658 - 2566 - Switch DMM to DC voltage; Remark:2613
Procedure Step
Published
08/18/2021 10:21 PM
2566 - Switch DMM to DC voltage
Instruction
Published
08/11/2021 3:41 PM
2613 - IO Fluke DMM Dial DC Volt
Remark
Published
11/02/2024 3:15 PM
2659 - 2567 - Locate ground test point; Remark:2610
Procedure Step
Published
08/23/2021 11:53 AM
2567 - Locate ground test point
Instruction
Published
08/11/2021 3:42 PM
2610 - The ground TP38 is located on the GHA-472 gamma board and might not be clearl...
Remark
Published
08/23/2021 11:41 AM
2660 - 2568 - Connect HV probe to ground; Remark:2609
Procedure Step
Published
08/23/2021 11:54 AM
2568 - Connect HV probe to ground
Instruction
Published
08/11/2021 3:42 PM
2609 - Connect black test lead of HV probe to TP38. Verify good connection.
Remark
Published
08/11/2021 4:08 PM
2661 - 2569 - Locate HV test point; Remark:2607
Procedure Step
Published
08/23/2021 11:42 AM
2569 - Locate HV test point
Instruction
Published
08/23/2021 11:41 AM
2607 - The HV TP34 is located on the GHA-472 gamma board and might not be clearly la...
Remark
Published
08/11/2021 4:09 PM
2662 - 2570 - Connect HV probe to test point; Remark:2605
Procedure Step
Published
08/23/2021 11:54 AM
2638 - Warning : The test point has high voltage. Only contact the test point with the high vo...
Annotation
Published
10/04/2022 11:21 AM
2570 - Connect HV probe to test point
Instruction
Published
08/23/2021 11:30 AM
2605 - Contact TP34 with tip of red HV probe.
Remark
Published
08/11/2021 4:10 PM
2663 - 2571 - Document voltage; Remark:2589
Procedure Step
Published
08/23/2021 11:55 AM
2639 - Standard : Typical values are between 650 and 850 Volts DC. Older units might have highe...
Annotation
Published
10/04/2022 11:17 AM
2571 - Document voltage
Instruction
Published
08/11/2021 3:45 PM
2589 - The number indicated on the DMM must be multiplied by 1000 if the 80K-40 prob...
Remark
Published
08/11/2021 4:11 PM
2664 - 2572 - Remove HV probe from PRM-470; Remark:
Procedure Step
Published
08/23/2021 11:55 AM
2572 - Remove HV probe from PRM-470
Instruction
Published
08/11/2021 3:46 PM
2665 - 2573 - Adjust gains; Remark:
Procedure Step
Published
08/23/2021 11:55 AM
2573 - Adjust gains
Instruction
Published
08/11/2021 3:46 PM
2666 - 2574 - Connect leads to stage 1 test points; Remark:2602
Procedure Step
Published
08/23/2021 11:56 AM
2574 - Connect leads to stage 1 test points
Instruction
Published
08/11/2021 3:47 PM
2602 - Black test lead connects to TP20. Red test lead connects to TP1.
Remark
Published
05/03/2022 4:24 PM
2667 - 2575 - Verify Cs-137 source is on center of gamma detector; Remark:2601
Procedure Step
Published
08/23/2021 11:56 AM
2575 - Verify Cs-137 source is on center of gamma detector
Instruction
Published
08/11/2021 3:47 PM
2601 - IO PRM-470 Source on Gamma Detector
Remark
Published
11/02/2024 3:02 PM
2668 - 2576 - Adjust stage 1 gain; Remark:2599
Procedure Step
Published
08/23/2021 11:56 AM
2640 - Standard : 1st stage gain = Peak location should be at channel 115 +/- 3 channels.
Annotation
Published
10/04/2022 11:18 AM
2576 - Adjust stage 1 gain
Instruction
Published
08/11/2021 3:48 PM
2599 - Use precision slotted (tweaker) screwdriver to adjust R10 until peak is cente...
Remark
Published
08/11/2021 4:14 PM
2669 - 2559 - Collect stage 1 spectrum; Remark:2598
Procedure Step
Published
08/23/2021 11:57 AM
2598 - Place the cursor at channel 115 to monitor the counts.
Remark
Published
05/03/2022 12:01 PM
2670 - 2560 - Save stage 1 spectrum; Remark:2597
Procedure Step
Published
08/23/2021 11:57 AM
2597 - Use the correct file naming convention. Example: US_Richland_CG_102...
Remark
Published
08/11/2021 4:15 PM
2671 - 2577 - Connect to stage 2 test point; Remark:2596
Procedure Step
Published
08/23/2021 11:58 AM
2577 - Connect to stage 2 test point
Instruction
Published
08/11/2021 3:49 PM
2596 - Move red test lead to TP2.
Remark
Published
08/11/2021 4:16 PM
2672 - 2578 - Adjust stage 2 gain; Remark:2593
Procedure Step
Published
08/23/2021 11:58 AM
2641 - Standard : 2nd stage gain = Peak location should be at channel 310 +/- 5 channels.
Annotation
Published
10/04/2022 11:17 AM
2578 - Adjust stage 2 gain
Instruction
Published
08/11/2021 3:50 PM
2593 - Use Tweaker to adjust R17 (may not be labeled on board) until peak is centere...
Remark
Published
08/11/2021 4:16 PM
2673 - 2562 - Collect stage 2 spectrum; Remark:2592
Procedure Step
Published
08/23/2021 11:59 AM
2592 - Place the cursor at channel 310 to monitor the counts.
Remark
Published
08/11/2021 4:17 PM
2674 - 2563 - Save stage 2 spectrum; Remark:2591
Procedure Step
Published
08/23/2021 11:59 AM
2591 - Use the correct file naming convention. Example: US_Richland_CG_102...
Remark
Published
08/11/2021 4:18 PM
2675 - 2579 - Remove test leads; Remark:
Procedure Step
Published
08/23/2021 11:59 AM
2579 - Remove test leads
Instruction
Published
08/11/2021 3:51 PM
2676 - 2580 - Disconnect MCA; Remark:
Procedure Step
Published
08/23/2021 12:00 PM
2580 - Disconnect MCA
Instruction
Published
08/11/2021 3:51 PM
2677 - 2581 - Remove radioactive source; Remark:
Procedure Step
Published
08/23/2021 12:00 PM
2581 - Remove radioactive source
Instruction
Published
08/11/2021 3:52 PM
2678 - 2582 - Measure post-alignment high voltage; Remark:
Procedure Step
Published
08/23/2021 12:00 PM
2582 - Measure post-alignment high voltage
Instruction
Published
08/11/2021 3:53 PM
2679 - 2583 - Measure high voltage; Remark:2590
Procedure Step
Published
08/23/2021 12:01 PM
2583 - Measure high voltage
Instruction
Published
08/11/2021 3:54 PM
2590 - Repeat high voltage measurement steps provided earlier in this procedure....
Remark
Published
08/11/2021 4:19 PM
2680 - 2571 - Document voltage; Remark:2589
Procedure Step
Published
08/23/2021 12:01 PM
2681 - 2572 - Remove HV probe from PRM-470; Remark:2588
Procedure Step
Published
08/23/2021 12:01 PM
2588 - Power off DMM. Carefully remove test leads.
Remark
Published
08/11/2021 4:20 PM
303 - 302 - Reassemble instrument; Remark:
Procedure Step
Published
10/07/2022 1:49 PM
302 - Reassemble instrument
Instruction
Published
06/16/2021 11:28 PM
2684 - 307 - Replace front cover; Remark:
Procedure Step
Published
08/23/2021 12:02 PM
304 - Caution : Ensure all wiring is inside the instrument while replacing cover.
Annotation
Published
10/04/2022 11:10 AM
307 - Replace front cover
Instruction
Published
07/20/2021 3:57 PM
310 - 309 - Tighten four (4) cover screws; Remark:417
Procedure Step
Published
08/11/2021 2:04 PM
569 - Caution : Do not overtighten screws.
Annotation
Published
06/16/2021 2:31 PM
309 - Tighten four (4) cover screws
Instruction
Published
07/22/2021 1:02 PM
417 - Use a medium Phillips (PH2) screwdriver.
Remark
Published
07/22/2021 1:18 PM
320 - 319 - Perform operational test; Remark:347
Procedure Step
Published
08/12/2021 7:12 AM
319 - Perform operational test
Instruction
Published
06/10/2021 8:31 PM
347 - Perform DET-HHD-RAP-RM01 PRM-470 Operational Test.
Remark
Published
07/21/2021 12:22 PM
2682 - 2584 - Perform efficiency test; Remark:2587
Procedure Step
Published
08/23/2021 12:02 PM
2584 - Perform efficiency test
Instruction
Published
08/11/2021 3:55 PM
2587 - DET-HHD-RAP-RM05, PRM-470 Efficiency Test
Remark
Published
08/11/2021 4:22 PM
322 - 321 - Document maintenance actions; Remark:
Procedure Step
Published
06/17/2021 9:49 AM
321 - Document maintenance actions
Instruction
Published
04/21/2025 11:19 AM
2869 - 2585 - Document maintenance performed; Remark:2866
Procedure Step
Published
06/18/2021 5:58 PM
2585 - Document maintenance performed
Instruction
Published
07/09/2021 12:15 PM
2866 - Record observations, times, and results for the maintenance report.
Remark
Published
04/21/2025 11:39 AM
4706 - 4705 - Submit report; Remark:4864
Procedure Step
Published
06/29/2022 9:50 AM
4705 - Submit report
Instruction
Published
06/29/2022 9:50 AM
4864 - As specified by management or contractual obligations.
Remark
Published
07/28/2022 1:36 PM
Corrective Maintenance Procedure
Document Type
Published
03/02/2020 3:32 PM
30 minutes
Duration
Published
04/01/2020 11:35 AM
As Needed
Frequency
Published
04/01/2020 11:36 AM
Warning
Annotation Type
Published
03/02/2020 3:25 PM
Standard
Annotation Type
Published
03/02/2020 3:25 PM
Note
Annotation Type
Published
03/02/2020 3:25 PM
Caution
Annotation Type
Published
03/02/2020 3:24 PM
Technician 2
Skill Level
Published
04/09/2020 1:17 AM
Precision slotted (tweaker) screwdriver
Tools
Published
03/20/2021 6:23 PM
Amptek MCA8000D multichannel analyzer (MCA)
Tools
Published
03/20/2021 6:22 PM
Computer with MCA software installed (Amptek DppMCA)
Tools
Published
03/20/2021 6:22 PM
Mini-USB male to USB-A male cable
Tools
Published
03/19/2021 3:37 PM
Test leads for MCA
Tools
Published
03/19/2021 3:37 PM
Fluke 179 Digital Multimeter (DMM)
Tools
Published
03/20/2021 6:27 PM
Test leads for DMM
Tools
Published
03/20/2021 6:28 PM
Fluke 80K-40 high voltage (HV) probe
Tools
Published
03/20/2021 6:23 PM
Medium Phillips (PH2) screwdriver
Tools
Published
04/24/2020 4:40 PM
PRM-470 Disconnect Charger Cable
படம்
Published
03/16/2021 1:39 AM
PRM-470_Partial_Power_Button_Red_Highlight.png
படம்
Published
06/18/2021 6:28 PM
PRM470_Remove_Screws_Top_Case
படம்
Published
05/08/2020 6:05 PM
PRM-470_di_CGN_open_00536
படம்
Published
02/19/2023 11:26 AM
Amptek MCA miniUSB connection
படம்
Published
03/17/2021 2:46 AM
Amptek MCA connection to computer
படம்
Published
03/17/2021 2:46 AM
Amptek MCA connection to signal input
படம்
Published
03/17/2021 2:46 AM
Amptek Software Logo DppMCA
படம்
Published
03/17/2021 2:46 AM
Amptek Software DppMCA Load Settings
படம்
Published
03/17/2021 2:46 AM
Amptek Software DppMCA Settings
படம்
Published
03/17/2021 2:46 AM
PRM-470 Gamma Source on Detector Interior
படம்
Published
03/17/2021 2:46 AM
PRM-470 TP20 Ground on main CB
படம்
Published
03/17/2021 2:46 AM
Amptek Software DppMCA Traffic Light
படம்
Published
03/17/2021 2:46 AM
Amptek Software DppMCA Spectra Channel 120
படம்
Published
03/17/2021 2:46 AM
Amptek Software DppMCA Save File
படம்
Published
03/17/2021 2:46 AM
PRM-470 GHA-472 TP2
படம்
Published
03/17/2021 2:46 AM
Amptek Software DppMCA Spectra Channel 291
படம்
Published
03/17/2021 2:46 AM
Fluke DMM on DC Voltage Dial
படம்
Published
03/16/2021 1:39 AM
PRM-470 GHA-472 Locate TP38
படம்
Published
03/17/2021 2:46 AM
PRM-470 GHA-472 Connect TP38
படம்
Published
03/17/2021 2:46 AM
PRM-470 GHA-472 Locate TP34
படம்
Published
03/17/2021 2:46 AM
PRM-470 GHA-472 Connect TP34
படம்
Published
03/17/2021 2:46 AM
Fluke DMM Display 0.745 in HV Probe Multiplier
படம்
Published
03/17/2021 2:46 AM
PRM-470 GHA-472 Connect TP1 Stage 1
படம்
Published
03/17/2021 2:46 AM
PRM-470 GHA-472 Adjust R10
படம்
Published
02/19/2023 11:19 AM
Amptek Software DppMCA Spectra Channel 115
படம்
Published
03/17/2021 2:46 AM
PRM-470 GHA-472 Adjust R17
படம்
Published
03/17/2021 2:46 AM
Amptek Software DppMCA Spectra Channel 310
படம்
Published
03/17/2021 2:46 AM
PRM-470_Tighten_4_cover_screws
படம்
Published
05/10/2020 8:22 PM