247 - 257 - Prepare instrument; Remark: |
Procedure Step
|
Published
|
04/11/2025 9:08 PM
|
257 - Prepare instrument |
Instruction
|
Published
|
04/11/2025 9:07 PM
|
2548 - 205 - Disconnect charger; Remark:2547 |
Procedure Step
|
Published
|
08/02/2021 12:46 PM
|
205 - Disconnect charger |
Instruction
|
Published
|
07/23/2021 2:42 PM
|
2547 - IO PRM-470 Remove Charger Cable |
Remark
|
Published
|
11/02/2024 3:10 PM
|
2633 - 220 - Power on instrument; Remark:2545 |
Procedure Step
|
Published
|
08/12/2021 12:19 PM
|
220 - Power on instrument |
Instruction
|
Published
|
04/06/2025 7:00 PM
|
2545 - IO PRM-470 Power Button Red Box |
Remark
|
Published
|
10/29/2024 9:30 PM
|
261 - 65 - Loosen four (4) cover screws; Remark:264 |
Procedure Step
|
Published
|
08/12/2021 7:25 AM
|
65 - Loosen four (4) cover screws |
Instruction
|
Published
|
07/22/2021 12:38 PM
|
264 - Use a medium Phillips (PH2) screwdriver. Screws do not need to be completely ... |
Remark
|
Published
|
07/20/2021 3:59 PM
|
2642 - 262 - Remove instrument cover; Remark:2631 |
Procedure Step
|
Published
|
08/23/2021 11:44 AM
|
2634 - Warning : Do not touch circuit board components as there are high voltage energized tes... |
Annotation
|
Published
|
08/23/2021 11:27 AM
|
262 - Remove instrument cover |
Instruction
|
Published
|
07/20/2021 3:35 PM
|
2631 - IO PRM-470 Cover Open Action |
Remark
|
Published
|
11/02/2024 3:12 PM
|
2643 - 2551 - Connect Multichannel Analyzer (MCA); Remark: |
Procedure Step
|
Published
|
08/23/2021 11:44 AM
|
2551 - Connect Multichannel Analyzer (MCA) |
Instruction
|
Published
|
08/03/2021 2:13 PM
|
2644 - 2552 - Connect MCA to computer; Remark:2630 |
Procedure Step
|
Published
|
08/23/2021 11:44 AM
|
2552 - Connect MCA to computer |
Instruction
|
Published
|
08/03/2021 2:15 PM
|
2630 - Use provided Mini-USB [universal serial bus] to USB cable. |
Remark
|
Published
|
08/23/2021 11:29 AM
|
2645 - 2553 - Attach test leads to MCA; Remark:2629 |
Procedure Step
|
Published
|
08/23/2021 11:37 AM
|
2553 - Attach test leads to MCA |
Instruction
|
Published
|
08/03/2021 2:15 PM
|
2629 - Connect to the SIGNAL input. |
Remark
|
Published
|
08/23/2021 11:38 AM
|
2646 - 2554 - Collect pre-alignment Spectra; Remark: |
Procedure Step
|
Published
|
08/23/2021 11:45 AM
|
2554 - Collect pre-alignment Spectra |
Instruction
|
Published
|
08/03/2021 2:16 PM
|
2647 - 2555 - Start Amptek software; Remark:2627 |
Procedure Step
|
Published
|
08/23/2021 12:04 PM
|
2555 - Start Amptek software |
Instruction
|
Published
|
08/03/2021 2:17 PM
|
2627 - IO Amptek Icon DppMCA |
Remark
|
Published
|
11/02/2024 3:13 PM
|
2648 - 2556 - Verify MCA settings; Remark:2626 |
Procedure Step
|
Published
|
08/23/2021 11:40 AM
|
2556 - Verify MCA settings |
Instruction
|
Published
|
08/23/2021 11:39 AM
|
2626 - Settings should match the image below. |
Remark
|
Published
|
08/23/2021 11:39 AM
|
2649 - 2557 - Place Cs-137 source on gamma detector; Remark:2625 |
Procedure Step
|
Published
|
08/23/2021 11:46 AM
|
2557 - Place Cs-137 source on gamma detector |
Instruction
|
Published
|
08/11/2021 3:25 PM
|
2625 - Center the source on the detector. |
Remark
|
Published
|
08/11/2021 3:27 PM
|
2650 - 2558 - Connect leads to stage 1 test points; Remark:2624 |
Procedure Step
|
Published
|
08/23/2021 11:46 AM
|
2558 - Connect leads to stage 1 test points |
Instruction
|
Published
|
08/11/2021 3:30 PM
|
2624 - Black test lead connects to TP20. Red test lead connects to TP1. |
Remark
|
Published
|
08/11/2021 3:59 PM
|
2651 - 2559 - Collect stage 1 spectrum; Remark:2622 |
Procedure Step
|
Published
|
08/23/2021 11:47 AM
|
2635 - Standard : At least 2,000 counts should be recorded on the peak channel. |
Annotation
|
Published
|
10/04/2022 11:15 AM
|
2636 - Note : Hot keys for DppMCA software: “A” will clear spectrum and restart acquisi... |
Annotation
|
Published
|
10/04/2022 11:13 AM
|
2559 - Collect stage 1 spectrum |
Instruction
|
Published
|
08/11/2021 3:30 PM
|
2622 - The traffic light icon will start/stop data acquisition. |
Remark
|
Published
|
08/11/2021 4:00 PM
|
2623 - Placing the cursor at the peak location will aid in monitoring the counts in ... |
Remark
|
Published
|
08/11/2021 4:01 PM
|
2652 - 2560 - Save stage 1 spectrum; Remark:2620 |
Procedure Step
|
Published
|
08/23/2021 11:47 AM
|
2637 - Standard : Use the following file naming convention: CO_SITE_MO_SN_STG_PP CO =... |
Annotation
|
Published
|
08/23/2021 11:50 AM
|
2560 - Save stage 1 spectrum |
Instruction
|
Published
|
08/11/2021 3:31 PM
|
2620 - IO Amptek Save File in DppMCA |
Remark
|
Published
|
11/02/2024 3:14 PM
|
2621 - Use the correct file naming convention. Example: US_Richland_CG_102... |
Remark
|
Published
|
08/11/2021 4:03 PM
|
2653 - 2561 - Connect leads to stage 2 test point; Remark:2619 |
Procedure Step
|
Published
|
08/23/2021 11:51 AM
|
2561 - Connect leads to stage 2 test point |
Instruction
|
Published
|
08/11/2021 3:32 PM
|
2619 - Red test lead connects to TP2. |
Remark
|
Published
|
08/11/2021 4:03 PM
|
2654 - 2562 - Collect stage 2 spectrum; Remark:2617 |
Procedure Step
|
Published
|
08/23/2021 11:52 AM
|
2562 - Collect stage 2 spectrum |
Instruction
|
Published
|
08/11/2021 3:33 PM
|
2617 - Start data collection. |
Remark
|
Published
|
08/11/2021 4:04 PM
|
2618 - Placing the cursor at the peak location will aid in monitoring the counts in ... |
Remark
|
Published
|
08/11/2021 4:05 PM
|
2655 - 2563 - Save stage 2 spectrum; Remark:2616 |
Procedure Step
|
Published
|
08/23/2021 11:52 AM
|
2563 - Save stage 2 spectrum |
Instruction
|
Published
|
08/11/2021 3:38 PM
|
2616 - Use the correct file naming convention. Example: US_Richland_CG_102... |
Remark
|
Published
|
08/11/2021 4:06 PM
|
2656 - 2564 - Measure pre-alignment high voltage; Remark: |
Procedure Step
|
Published
|
05/03/2022 12:00 PM
|
2564 - Measure pre-alignment high voltage |
Instruction
|
Published
|
05/03/2022 12:00 PM
|
2657 - 2565 - Connect HV probe to DMM; Remark:2614 |
Procedure Step
|
Published
|
08/23/2021 11:53 AM
|
2565 - Connect HV probe to DMM |
Instruction
|
Published
|
08/11/2021 3:41 PM
|
2614 - Use Fluke 80K-40 high voltage (HV) probe and Fluke 179 DMM. |
Remark
|
Published
|
08/11/2021 4:06 PM
|
2658 - 2566 - Switch DMM to DC voltage; Remark:2613 |
Procedure Step
|
Published
|
08/18/2021 10:21 PM
|
2566 - Switch DMM to DC voltage |
Instruction
|
Published
|
08/11/2021 3:41 PM
|
2613 - IO Fluke DMM Dial DC Volt |
Remark
|
Published
|
11/02/2024 3:15 PM
|
2659 - 2567 - Locate ground test point; Remark:2610 |
Procedure Step
|
Published
|
08/23/2021 11:53 AM
|
2567 - Locate ground test point |
Instruction
|
Published
|
08/11/2021 3:42 PM
|
2610 - The ground TP38 is located on the GHA-472 gamma board and might not be clearl... |
Remark
|
Published
|
08/23/2021 11:41 AM
|
2660 - 2568 - Connect HV probe to ground; Remark:2609 |
Procedure Step
|
Published
|
08/23/2021 11:54 AM
|
2568 - Connect HV probe to ground |
Instruction
|
Published
|
08/11/2021 3:42 PM
|
2609 - Connect black test lead of HV probe to TP38. Verify good connection. |
Remark
|
Published
|
08/11/2021 4:08 PM
|
2661 - 2569 - Locate HV test point; Remark:2607 |
Procedure Step
|
Published
|
08/23/2021 11:42 AM
|
2569 - Locate HV test point |
Instruction
|
Published
|
08/23/2021 11:41 AM
|
2607 - The HV TP34 is located on the GHA-472 gamma board and might not be clearly la... |
Remark
|
Published
|
08/11/2021 4:09 PM
|
2662 - 2570 - Connect HV probe to test point; Remark:2605 |
Procedure Step
|
Published
|
08/23/2021 11:54 AM
|
2638 - Warning : The test point has high voltage. Only contact the test point with the high vo... |
Annotation
|
Published
|
10/04/2022 11:21 AM
|
2570 - Connect HV probe to test point |
Instruction
|
Published
|
08/23/2021 11:30 AM
|
2605 - Contact TP34 with tip of red HV probe. |
Remark
|
Published
|
08/11/2021 4:10 PM
|
2663 - 2571 - Document voltage; Remark:2589 |
Procedure Step
|
Published
|
08/23/2021 11:55 AM
|
2639 - Standard : Typical values are between 650 and 850 Volts DC. Older units might have highe... |
Annotation
|
Published
|
10/04/2022 11:17 AM
|
2571 - Document voltage |
Instruction
|
Published
|
08/11/2021 3:45 PM
|
2589 - The number indicated on the DMM must be multiplied by 1000 if the 80K-40 prob... |
Remark
|
Published
|
08/11/2021 4:11 PM
|
2664 - 2572 - Remove HV probe from PRM-470; Remark: |
Procedure Step
|
Published
|
08/23/2021 11:55 AM
|
2572 - Remove HV probe from PRM-470 |
Instruction
|
Published
|
08/11/2021 3:46 PM
|
2665 - 2573 - Adjust gains; Remark: |
Procedure Step
|
Published
|
08/23/2021 11:55 AM
|
2573 - Adjust gains |
Instruction
|
Published
|
08/11/2021 3:46 PM
|
2666 - 2574 - Connect leads to stage 1 test points; Remark:2602 |
Procedure Step
|
Published
|
08/23/2021 11:56 AM
|
2574 - Connect leads to stage 1 test points |
Instruction
|
Published
|
08/11/2021 3:47 PM
|
2602 - Black test lead connects to TP20. Red test lead connects to TP1. |
Remark
|
Published
|
05/03/2022 4:24 PM
|
2667 - 2575 - Verify Cs-137 source is on center of gamma detector; Remark:2601 |
Procedure Step
|
Published
|
08/23/2021 11:56 AM
|
2575 - Verify Cs-137 source is on center of gamma detector |
Instruction
|
Published
|
08/11/2021 3:47 PM
|
2601 - IO PRM-470 Source on Gamma Detector |
Remark
|
Published
|
11/02/2024 3:02 PM
|
2668 - 2576 - Adjust stage 1 gain; Remark:2599 |
Procedure Step
|
Published
|
08/23/2021 11:56 AM
|
2640 - Standard : 1st stage gain = Peak location should be at channel 115 +/- 3 channels. |
Annotation
|
Published
|
10/04/2022 11:18 AM
|
2576 - Adjust stage 1 gain |
Instruction
|
Published
|
08/11/2021 3:48 PM
|
2599 - Use precision slotted (tweaker) screwdriver to adjust R10 until peak is cente... |
Remark
|
Published
|
08/11/2021 4:14 PM
|
2669 - 2559 - Collect stage 1 spectrum; Remark:2598 |
Procedure Step
|
Published
|
08/23/2021 11:57 AM
|
2598 - Place the cursor at channel 115 to monitor the counts. |
Remark
|
Published
|
05/03/2022 12:01 PM
|
2670 - 2560 - Save stage 1 spectrum; Remark:2597 |
Procedure Step
|
Published
|
08/23/2021 11:57 AM
|
2597 - Use the correct file naming convention. Example: US_Richland_CG_102... |
Remark
|
Published
|
08/11/2021 4:15 PM
|
2671 - 2577 - Connect to stage 2 test point; Remark:2596 |
Procedure Step
|
Published
|
08/23/2021 11:58 AM
|
2577 - Connect to stage 2 test point |
Instruction
|
Published
|
08/11/2021 3:49 PM
|
2596 - Move red test lead to TP2. |
Remark
|
Published
|
08/11/2021 4:16 PM
|
2672 - 2578 - Adjust stage 2 gain; Remark:2593 |
Procedure Step
|
Published
|
08/23/2021 11:58 AM
|
2641 - Standard : 2nd stage gain = Peak location should be at channel 310 +/- 5 channels. |
Annotation
|
Published
|
10/04/2022 11:17 AM
|
2578 - Adjust stage 2 gain |
Instruction
|
Published
|
08/11/2021 3:50 PM
|
2593 - Use Tweaker to adjust R17 (may not be labeled on board) until peak is centere... |
Remark
|
Published
|
08/11/2021 4:16 PM
|
2673 - 2562 - Collect stage 2 spectrum; Remark:2592 |
Procedure Step
|
Published
|
08/23/2021 11:59 AM
|
2592 - Place the cursor at channel 310 to monitor the counts. |
Remark
|
Published
|
08/11/2021 4:17 PM
|
2674 - 2563 - Save stage 2 spectrum; Remark:2591 |
Procedure Step
|
Published
|
08/23/2021 11:59 AM
|
2591 - Use the correct file naming convention. Example: US_Richland_CG_102... |
Remark
|
Published
|
08/11/2021 4:18 PM
|
2675 - 2579 - Remove test leads; Remark: |
Procedure Step
|
Published
|
08/23/2021 11:59 AM
|
2579 - Remove test leads |
Instruction
|
Published
|
08/11/2021 3:51 PM
|
2676 - 2580 - Disconnect MCA; Remark: |
Procedure Step
|
Published
|
08/23/2021 12:00 PM
|
2580 - Disconnect MCA |
Instruction
|
Published
|
08/11/2021 3:51 PM
|
2677 - 2581 - Remove radioactive source; Remark: |
Procedure Step
|
Published
|
08/23/2021 12:00 PM
|
2581 - Remove radioactive source |
Instruction
|
Published
|
08/11/2021 3:52 PM
|
2678 - 2582 - Measure post-alignment high voltage; Remark: |
Procedure Step
|
Published
|
08/23/2021 12:00 PM
|
2582 - Measure post-alignment high voltage |
Instruction
|
Published
|
08/11/2021 3:53 PM
|
2679 - 2583 - Measure high voltage; Remark:2590 |
Procedure Step
|
Published
|
08/23/2021 12:01 PM
|
2583 - Measure high voltage |
Instruction
|
Published
|
08/11/2021 3:54 PM
|
2590 - Repeat high voltage measurement steps provided earlier in this procedure.... |
Remark
|
Published
|
08/11/2021 4:19 PM
|
2680 - 2571 - Document voltage; Remark:2589 |
Procedure Step
|
Published
|
08/23/2021 12:01 PM
|
2681 - 2572 - Remove HV probe from PRM-470; Remark:2588 |
Procedure Step
|
Published
|
08/23/2021 12:01 PM
|
2588 - Power off DMM. Carefully remove test leads. |
Remark
|
Published
|
08/11/2021 4:20 PM
|
303 - 302 - Reassemble instrument; Remark: |
Procedure Step
|
Published
|
10/07/2022 1:49 PM
|
302 - Reassemble instrument |
Instruction
|
Published
|
06/16/2021 11:28 PM
|
2684 - 307 - Replace front cover; Remark: |
Procedure Step
|
Published
|
08/23/2021 12:02 PM
|
304 - Caution : Ensure all wiring is inside the instrument while replacing cover. |
Annotation
|
Published
|
10/04/2022 11:10 AM
|
307 - Replace front cover |
Instruction
|
Published
|
07/20/2021 3:57 PM
|
310 - 309 - Tighten four (4) cover screws; Remark:417 |
Procedure Step
|
Published
|
08/11/2021 2:04 PM
|
569 - Caution : Do not overtighten screws. |
Annotation
|
Published
|
06/16/2021 2:31 PM
|
309 - Tighten four (4) cover screws |
Instruction
|
Published
|
07/22/2021 1:02 PM
|
417 - Use a medium Phillips (PH2) screwdriver. |
Remark
|
Published
|
07/22/2021 1:18 PM
|
320 - 319 - Perform operational test; Remark:347 |
Procedure Step
|
Published
|
08/12/2021 7:12 AM
|
319 - Perform operational test |
Instruction
|
Published
|
06/10/2021 8:31 PM
|
347 - Perform DET-HHD-RAP-RM01 PRM-470 Operational Test. |
Remark
|
Published
|
07/21/2021 12:22 PM
|
2682 - 2584 - Perform efficiency test; Remark:2587 |
Procedure Step
|
Published
|
08/23/2021 12:02 PM
|
2584 - Perform efficiency test |
Instruction
|
Published
|
08/11/2021 3:55 PM
|
2587 - DET-HHD-RAP-RM05, PRM-470 Efficiency Test |
Remark
|
Published
|
08/11/2021 4:22 PM
|
322 - 321 - Document maintenance actions; Remark: |
Procedure Step
|
Published
|
06/17/2021 9:49 AM
|
321 - Document maintenance actions |
Instruction
|
Published
|
04/21/2025 11:19 AM
|
2869 - 2585 - Document maintenance performed; Remark:2866 |
Procedure Step
|
Published
|
06/18/2021 5:58 PM
|
2585 - Document maintenance performed |
Instruction
|
Published
|
07/09/2021 12:15 PM
|
2866 - Record observations, times, and results for the maintenance report. |
Remark
|
Published
|
04/21/2025 11:39 AM
|
4706 - 4705 - Submit report; Remark:4864 |
Procedure Step
|
Published
|
06/29/2022 9:50 AM
|
4705 - Submit report |
Instruction
|
Published
|
06/29/2022 9:50 AM
|
4864 - As specified by management or contractual obligations. |
Remark
|
Published
|
07/28/2022 1:36 PM
|
Corrective Maintenance Procedure |
Document Type
|
Published
|
03/02/2020 3:32 PM
|
30 minutes |
Duration
|
Published
|
04/01/2020 11:35 AM
|
As Needed |
Frequency
|
Published
|
04/01/2020 11:36 AM
|
Warning |
Annotation Type
|
Published
|
03/02/2020 3:25 PM
|
Standard |
Annotation Type
|
Published
|
03/02/2020 3:25 PM
|
Note |
Annotation Type
|
Published
|
03/02/2020 3:25 PM
|
Caution |
Annotation Type
|
Published
|
03/02/2020 3:24 PM
|
Technician 2 |
Skill Level
|
Published
|
04/09/2020 1:17 AM
|
Precision slotted (tweaker) screwdriver |
Tools
|
Published
|
03/20/2021 6:23 PM
|
Amptek MCA8000D multichannel analyzer (MCA) |
Tools
|
Published
|
03/20/2021 6:22 PM
|
Computer with MCA software installed (Amptek DppMCA) |
Tools
|
Published
|
03/20/2021 6:22 PM
|
Mini-USB male to USB-A male cable |
Tools
|
Published
|
03/19/2021 3:37 PM
|
Test leads for MCA |
Tools
|
Published
|
03/19/2021 3:37 PM
|
Fluke 179 Digital Multimeter (DMM) |
Tools
|
Published
|
03/20/2021 6:27 PM
|
Test leads for DMM |
Tools
|
Published
|
03/20/2021 6:28 PM
|
Fluke 80K-40 high voltage (HV) probe |
Tools
|
Published
|
03/20/2021 6:23 PM
|
Medium Phillips (PH2) screwdriver |
Tools
|
Published
|
04/24/2020 4:40 PM
|
PRM-470 Disconnect Charger Cable |
படம்
|
Published
|
03/16/2021 1:39 AM
|
PRM-470_Partial_Power_Button_Red_Highlight.png |
படம்
|
Published
|
06/18/2021 6:28 PM
|
PRM470_Remove_Screws_Top_Case |
படம்
|
Published
|
05/08/2020 6:05 PM
|
PRM-470_di_CGN_open_00536 |
படம்
|
Published
|
02/19/2023 11:26 AM
|
Amptek MCA miniUSB connection |
படம்
|
Published
|
03/17/2021 2:46 AM
|
Amptek MCA connection to computer |
படம்
|
Published
|
03/17/2021 2:46 AM
|
Amptek MCA connection to signal input |
படம்
|
Published
|
03/17/2021 2:46 AM
|
Amptek Software Logo DppMCA |
படம்
|
Published
|
03/17/2021 2:46 AM
|
Amptek Software DppMCA Load Settings |
படம்
|
Published
|
03/17/2021 2:46 AM
|
Amptek Software DppMCA Settings |
படம்
|
Published
|
03/17/2021 2:46 AM
|
PRM-470 Gamma Source on Detector Interior |
படம்
|
Published
|
03/17/2021 2:46 AM
|
PRM-470 TP20 Ground on main CB |
படம்
|
Published
|
03/17/2021 2:46 AM
|
Amptek Software DppMCA Traffic Light |
படம்
|
Published
|
03/17/2021 2:46 AM
|
Amptek Software DppMCA Spectra Channel 120 |
படம்
|
Published
|
03/17/2021 2:46 AM
|
Amptek Software DppMCA Save File |
படம்
|
Published
|
03/17/2021 2:46 AM
|
PRM-470 GHA-472 TP2 |
படம்
|
Published
|
03/17/2021 2:46 AM
|
Amptek Software DppMCA Spectra Channel 291 |
படம்
|
Published
|
03/17/2021 2:46 AM
|
Fluke DMM on DC Voltage Dial |
படம்
|
Published
|
03/16/2021 1:39 AM
|
PRM-470 GHA-472 Locate TP38 |
படம்
|
Published
|
03/17/2021 2:46 AM
|
PRM-470 GHA-472 Connect TP38 |
படம்
|
Published
|
03/17/2021 2:46 AM
|
PRM-470 GHA-472 Locate TP34 |
படம்
|
Published
|
03/17/2021 2:46 AM
|
PRM-470 GHA-472 Connect TP34 |
படம்
|
Published
|
03/17/2021 2:46 AM
|
Fluke DMM Display 0.745 in HV Probe Multiplier |
படம்
|
Published
|
03/17/2021 2:46 AM
|
PRM-470 GHA-472 Connect TP1 Stage 1 |
படம்
|
Published
|
03/17/2021 2:46 AM
|
PRM-470 GHA-472 Adjust R10 |
படம்
|
Published
|
02/19/2023 11:19 AM
|
Amptek Software DppMCA Spectra Channel 115 |
படம்
|
Published
|
03/17/2021 2:46 AM
|
PRM-470 GHA-472 Adjust R17 |
படம்
|
Published
|
03/17/2021 2:46 AM
|
Amptek Software DppMCA Spectra Channel 310 |
படம்
|
Published
|
03/17/2021 2:46 AM
|
PRM-470_Tighten_4_cover_screws |
படம்
|
Published
|
05/10/2020 8:22 PM
|