Rapiscan PM-700 Pedestrian Monitor |
Device
|
Published
|
06/20/2024 11:38 AM
|
7478 - 1401 - Establish Initial Conditions; Remark: |
Procedure Step
|
Published
|
09/01/2023 7:48 PM
|
1401 - Establish Initial Conditions |
Instruction
|
Published
|
09/30/2022 3:14 PM
|
7452 - 7231 - Close lane; Remark:7415 |
Procedure Step
|
Published
|
06/02/2023 5:12 PM
|
7231 - Close lane |
Instruction
|
Published
|
04/18/2023 1:00 PM
|
7415 - Re-route pedestrian traffic. |
Remark
|
Published
|
06/02/2023 1:08 PM
|
7453 - 7232 - Open RPM door; Remark:7267 |
Procedure Step
|
Published
|
06/02/2023 5:24 PM
|
7232 - Open RPM door |
Instruction
|
Published
|
04/18/2023 1:02 PM
|
7267 - Open all doors needed to access components. |
Remark
|
Published
|
09/16/2023 4:54 PM
|
7454 - 7290 - Disable tamper switches; Remark:7416 |
Procedure Step
|
Published
|
06/02/2023 5:25 PM
|
7290 - Disable tamper switches |
Instruction
|
Published
|
05/01/2023 8:14 AM
|
7416 - Use a magnet to disable tamper switches for all open doors. Use adhesive tape... |
Remark
|
Published
|
06/02/2023 1:18 PM
|
7270 - 7235 - Power off RPM; Remark:7236 |
Procedure Step
|
Published
|
09/01/2023 7:57 PM
|
7235 - Power off RPM |
Instruction
|
Published
|
04/24/2023 12:30 PM
|
7236 - Move LD-260 switch to OFF position. The PWR ON |
Remark
|
Published
|
04/27/2023 4:25 PM
|
7479 - 7417 - Prepare New Occupancy Sensor; Remark: |
Procedure Step
|
Published
|
06/02/2023 6:13 PM
|
7417 - Prepare New Occupancy Sensor |
Instruction
|
Published
|
06/02/2023 1:39 PM
|
7456 - 7418 - Remove cover from new occupancy sensor; Remark:7419 |
Procedure Step
|
Published
|
06/02/2023 5:27 PM
|
7418 - Remove cover from new occupancy sensor |
Instruction
|
Published
|
06/02/2023 1:43 PM
|
7419 - Use a slotted screwdriver to pry the cover off from the side. |
Remark
|
Published
|
04/13/2025 5:44 PM
|
7457 - 7420 - Verify narrow field radar antenna is installed; Remark:7421 |
Procedure Step
|
Published
|
04/13/2025 6:18 PM
|
7420 - Verify narrow field radar antenna is installed |
Instruction
|
Published
|
04/13/2025 5:44 PM
|
7421 - The IXIO-DT1 should come with the narrow field antenna installed. |
Remark
|
Published
|
06/02/2023 2:14 PM
|
8901 - If needed, the antenna can be changed. Remove cover. Install narrow field ant... |
Remark
|
Published
|
09/25/2023 9:51 PM
|
7480 - 7422 - Uninstall Faulty Occupancy Sensor; Remark: |
Procedure Step
|
Published
|
06/02/2023 9:42 PM
|
7422 - Uninstall Faulty Occupancy Sensor |
Instruction
|
Published
|
06/02/2023 2:16 PM
|
7458 - 7423 - Remove Cover; Remark:7424 |
Procedure Step
|
Published
|
06/02/2023 5:28 PM
|
7423 - Remove Cover |
Instruction
|
Published
|
06/02/2023 2:18 PM
|
7424 - If needed, use a sharp utility knife to cut sealant around edges of sensor. A... |
Remark
|
Published
|
06/02/2023 2:21 PM
|
7459 - 7425 - Disconnect wire connector; Remark:7426 |
Procedure Step
|
Published
|
06/02/2023 5:29 PM
|
7425 - Disconnect wire connector |
Instruction
|
Published
|
06/02/2023 2:48 PM
|
7426 - The wire connector is located on the right side of existing sensor. |
Remark
|
Published
|
06/02/2023 2:53 PM
|
7460 - 7427 - Loosen two (2) mounting screws; Remark:7428 |
Procedure Step
|
Published
|
06/02/2023 5:30 PM
|
7429 - Note : Some existing occupancy sensors are installed using screws and nuts, ... |
Annotation
|
Published
|
06/02/2023 3:09 PM
|
7427 - Loosen two (2) mounting screws |
Instruction
|
Published
|
06/02/2023 2:56 PM
|
7428 - Use a medium Phillips (PH2) screwdriver. If screws and nuts were used, an adj... |
Remark
|
Published
|
06/02/2023 3:04 PM
|
7461 - 7430 - Remove faulty occupancy sensor; Remark:7431 |
Procedure Step
|
Published
|
06/02/2023 5:31 PM
|
7430 - Remove faulty occupancy sensor |
Instruction
|
Published
|
06/02/2023 3:11 PM
|
7431 - If a Wizard G3 sensor is being removed, push up on both sides to free the sen... |
Remark
|
Published
|
09/29/2023 1:49 PM
|
3397 - 3395 - Label faulty component; Remark:3396 |
Procedure Step
|
Published
|
07/21/2024 6:59 AM
|
3395 - Label faulty component |
Instruction
|
Published
|
08/07/2021 11:07 AM
|
3396 - Use tag or tape. Include date of removal, description of failure symptoms, co... |
Remark
|
Published
|
08/09/2021 11:35 AM
|
7481 - 7432 - Install new occupancy sensor; Remark: |
Procedure Step
|
Published
|
06/02/2023 9:46 PM
|
7432 - Install new occupancy sensor |
Instruction
|
Published
|
06/02/2023 3:27 PM
|
7463 - 7433 - Mount new sensor; Remark:7434 |
Procedure Step
|
Published
|
06/02/2023 5:32 PM
|
7433 - Mount new sensor |
Instruction
|
Published
|
06/02/2023 3:29 PM
|
7434 - First, slide left side onto mounting screw. |
Remark
|
Published
|
04/13/2025 5:44 PM
|
9206 - Then, place right side over mounting screw and push down. |
Remark
|
Published
|
09/29/2023 1:55 PM
|
7464 - 7435 - Tighten two (2) mounting screws; Remark:7436 |
Procedure Step
|
Published
|
06/02/2023 5:33 PM
|
7435 - Tighten two (2) mounting screws |
Instruction
|
Published
|
06/02/2023 3:40 PM
|
7436 - Use medium Phillips (PH2) screwdriver. Take care not to overtighten. |
Remark
|
Published
|
04/13/2025 5:45 PM
|
7482 - 7437 - Route wiring through clamp and connect; Remark:7488 |
Procedure Step
|
Published
|
06/02/2023 10:42 PM
|
7437 - Route wiring through clamp and connect |
Instruction
|
Published
|
06/02/2023 3:53 PM
|
7488 - Clamp and Connect |
Remark
|
Published
|
06/02/2023 10:49 PM
|
7465 - 7439 - Adjust angle of the radar antenna; Remark:7438 |
Procedure Step
|
Published
|
04/13/2025 6:19 PM
|
7439 - Adjust angle of the radar antenna |
Instruction
|
Published
|
04/13/2025 5:45 PM
|
7438 - The angle is adjusted by manually rotating the antenna up or down. The defaul... |
Remark
|
Published
|
09/29/2023 1:58 PM
|
7279 - 7249 - Return equipment to normal operating condition; Remark: |
Procedure Step
|
Published
|
04/27/2023 4:13 PM
|
7249 - Return equipment to normal operating condition |
Instruction
|
Published
|
04/08/2025 3:22 PM
|
7466 - 7440 - Hold door open; Remark:7441 |
Procedure Step
|
Published
|
06/02/2023 5:35 PM
|
7440 - Hold door open |
Instruction
|
Published
|
06/02/2023 4:10 PM
|
7441 - Do not move door. Door must remain stationary to prevent occupancy. |
Remark
|
Published
|
04/13/2025 5:45 PM
|
7280 - 7250 - Power on RPM; Remark:7251 |
Procedure Step
|
Published
|
04/27/2023 4:14 PM
|
7250 - Power on RPM |
Instruction
|
Published
|
05/01/2023 8:31 AM
|
7251 - Move LD-260 switch to ON position. The LED PWR ON |
Remark
|
Published
|
05/10/2023 3:14 PM
|
7468 - 7304 - Confirm RPM has restarted correctly; Remark:7487 |
Procedure Step
|
Published
|
06/02/2023 5:36 PM
|
7304 - Confirm RPM has restarted correctly |
Instruction
|
Published
|
05/01/2023 8:31 AM
|
7487 - The SC-770 controller will display "OK" following Power On Self-Test (POST) a... |
Remark
|
Published
|
06/02/2023 10:35 PM
|
7282 - 7254 - Confirm network connection; Remark:7255 |
Procedure Step
|
Published
|
04/27/2023 4:15 PM
|
7254 - Confirm network connection |
Instruction
|
Published
|
04/27/2023 2:22 PM
|
7255 - Contact operators to confirm communications have been reestablished between RPM ... |
Remark
|
Published
|
05/10/2023 3:15 PM
|
7470 - 7442 - Generate occupancy; Remark:7443 |
Procedure Step
|
Published
|
06/02/2023 5:37 PM
|
7442 - Generate occupancy |
Instruction
|
Published
|
06/02/2023 4:19 PM
|
7443 - Create motion in front of occupancy sensor. While holding the door open and s... |
Remark
|
Published
|
06/02/2023 4:21 PM
|
7471 - 7444 - Verify occupancy sensor functionality; Remark:7445 |
Procedure Step
|
Published
|
06/02/2023 5:38 PM
|
7444 - Verify occupancy sensor functionality |
Instruction
|
Published
|
06/02/2023 4:32 PM
|
7445 - IXIO-DT1 green sensor light will illuminate. |
Remark
|
Published
|
06/02/2023 4:35 PM
|
8973 - Left latch on the LCD screen will indicate a “closed” circuit. |
Remark
|
Published
|
09/25/2023 11:05 PM
|
8974 - SC-770 status will read “OCCUPIED”. |
Remark
|
Published
|
09/25/2023 11:06 PM
|
7472 - 7446 - Install sensor cover; Remark:7447 |
Procedure Step
|
Published
|
06/02/2023 5:38 PM
|
7446 - Install sensor cover |
Instruction
|
Published
|
06/02/2023 4:37 PM
|
7447 - The cover should snap into place. |
Remark
|
Published
|
06/02/2023 4:38 PM
|
7473 - 7448 - If needed, apply sealant; Remark:7449 |
Procedure Step
|
Published
|
06/02/2023 5:39 PM
|
7448 - If needed, apply sealant |
Instruction
|
Published
|
06/02/2023 4:39 PM
|
7449 - If used outdoors, sealant should be applied to top and sides of cover. Do not... |
Remark
|
Published
|
06/02/2023 4:41 PM
|
7474 - 7310 - Enable tamper switches; Remark:7451 |
Procedure Step
|
Published
|
06/02/2023 5:41 PM
|
7310 - Enable tamper switches |
Instruction
|
Published
|
05/01/2023 8:36 AM
|
7451 - Remove magnets and/or adhesive tape from door tamper switches. |
Remark
|
Published
|
04/13/2025 5:46 PM
|
7283 - 7256 - Close and lock all RPM doors; Remark: |
Procedure Step
|
Published
|
09/01/2023 11:45 PM
|
7256 - Close and lock all RPM doors |
Instruction
|
Published
|
04/27/2023 2:21 PM
|
7842 - 7820 - Inform system operators upon completion of maintenance action; Remark: |
Procedure Step
|
Published
|
07/07/2023 11:15 PM
|
7820 - Inform system operators upon completion of maintenance action |
Instruction
|
Published
|
07/07/2023 10:02 PM
|
322 - 321 - Document maintenance actions; Remark: |
Procedure Step
|
Published
|
06/17/2021 9:49 AM
|
321 - Document maintenance actions |
Instruction
|
Published
|
04/21/2025 11:19 AM
|
2869 - 2585 - Document maintenance performed; Remark:2866 |
Procedure Step
|
Published
|
06/18/2021 5:58 PM
|
2585 - Document maintenance performed |
Instruction
|
Published
|
07/09/2021 12:15 PM
|
2866 - Record observations, times, and results for the maintenance report. |
Remark
|
Published
|
04/21/2025 11:39 AM
|
4706 - 4705 - Submit report; Remark:4864 |
Procedure Step
|
Published
|
06/29/2022 9:50 AM
|
4705 - Submit report |
Instruction
|
Published
|
06/29/2022 9:50 AM
|
4864 - As specified by management or contractual obligations. |
Remark
|
Published
|
07/28/2022 1:36 PM
|
Corrective Maintenance Procedure |
Document Type
|
Published
|
03/02/2020 3:32 PM
|
Instrument is not functioning correctly |
Frequency
|
Published
|
12/19/2022 5:52 PM
|
Note |
Annotation Type
|
Published
|
03/02/2020 3:25 PM
|
Technician 1 |
Skill Level
|
Published
|
05/14/2020 2:56 PM
|
Keys to access RPM |
Replacement Parts
|
Published
|
04/27/2023 6:56 PM
|
Magnets and adhesive tape to disable door tamper switches |
Replacement Parts
|
Published
|
06/02/2023 10:08 PM
|
Medium slotted screwdriver |
Replacement Parts
|
Published
|
06/02/2023 10:08 PM
|
Medium Phillips (PH2) screwdriver |
Tools
|
Published
|
04/24/2020 4:40 PM
|
Adjustable wrench |
Replacement Parts
|
Published
|
06/02/2023 10:08 PM
|
Utility knife |
Tools
|
Published
|
05/19/2020 1:54 PM
|
Orange/yellow safety vest |
Replacement Parts
|
Published
|
04/27/2023 6:56 PM
|
Safety shoes |
Replacement Parts
|
Published
|
04/27/2023 6:56 PM
|
Gloves |
Replacement Parts
|
Published
|
05/10/2023 3:28 PM
|
Protective headwear: glasses, hard hat |
Replacement Parts
|
Published
|
05/10/2023 3:31 PM
|
Orange traffic cones |
Replacement Parts
|
Published
|
04/27/2023 6:56 PM
|
Disable tamper switch |
படம்
|
Published
|
09/07/2023 8:22 PM
|
Disable Tamper Switch |
படம்
|
Published
|
06/02/2023 2:28 PM
|
LD-260 Disconnect Switch Power Off |
படம்
|
Published
|
04/24/2023 12:49 PM
|
Remove Occupancy Sensor Cover |
படம்
|
Published
|
06/02/2023 2:38 PM
|
The IXIO-DT1 should come with the narrow field antenna installed |
படம்
|
Published
|
09/25/2023 8:35 PM
|
Verify narrow field radar antenna is installed |
படம்
|
Published
|
09/25/2023 8:38 PM
|
Verify narrow field radar antenna is installed 2 |
படம்
|
Published
|
09/25/2023 8:39 PM
|
Uninstall Occupancy Sensor Cover |
படம்
|
Published
|
06/02/2023 2:37 PM
|
Disconnect Wire Connector |
படம்
|
Published
|
06/02/2023 2:53 PM
|
Loosen Two Mounting screws |
படம்
|
Published
|
06/02/2023 3:04 PM
|
Remove faulty Occupancy Sensor |
படம்
|
Published
|
09/29/2023 1:47 PM
|
Push Occupancy Sensor to the right |
படம்
|
Published
|
09/29/2023 1:48 PM
|
Mount new sensor |
படம்
|
Published
|
09/25/2023 8:52 PM
|
Push Down Over Mounting Screw to Install Occupancy Sensor |
படம்
|
Published
|
06/02/2023 3:51 PM
|
Tighten Occupancy Sensor Mounting Screws |
படம்
|
Published
|
06/02/2023 3:48 PM
|
Route wiring through clamp and connect |
படம்
|
Published
|
06/02/2023 3:55 PM
|
Adjust angle of the radar antenna |
படம்
|
Published
|
09/25/2023 8:56 PM
|
Adjust angle of the radar antenna2 |
படம்
|
Published
|
09/25/2023 8:58 PM
|
LD-260 Disconnect Switch Power On |
படம்
|
Published
|
05/04/2023 3:37 PM
|
IXIO-DT1 green sensor light will illuminate |
படம்
|
Published
|
09/25/2023 9:37 PM
|
Verify occupancy sensor functionality |
படம்
|
Published
|
09/25/2023 9:38 PM
|
Verify occupancy sensor functionality2 |
படம்
|
Published
|
09/25/2023 9:39 PM
|
Install Occupancy Sensor Cover |
படம்
|
Published
|
06/02/2023 4:26 PM
|
Occupancy Sensor Sealant Application |
படம்
|
Published
|
06/02/2023 4:30 PM
|
Remove Magnet from Tamper.PNG |
படம்
|
Published
|
09/28/2023 9:37 AM
|
Remove Magnet on Tamper Switch |
படம்
|
Published
|
06/02/2023 4:31 PM
|