RPM Neutron Detector Contaminant Removal

Last Updated: 04/23/2025 1:42 AM

The following table lists all the components that make up the document.

Title Type Status Last Updated
Rapiscan VM-250 Vehicle Monitor
Device
Published
10/14/2024 9:50 AM
Rapiscan PM-700 Pedestrian Monitor
Device
Published
06/20/2024 11:38 AM
Rapiscan TM-850 Rail Monitor
Device
Published
09/18/2024 10:28 AM
9584 - 9543 - Neutron Tube Serial Number; Remark:
Procedure Step
Published
10/11/2023 8:02 AM
9543 - Neutron Tube Serial Number
Instruction
Published
10/10/2023 3:49 PM
9585 - 9544 - Record serial number; Remark:9546
Procedure Step
Published
10/11/2023 8:02 AM
9544 - Record serial number
Instruction
Published
10/10/2023 3:49 PM
9546 - Only performed on detector tubes removed from the RPM.
Remark
Published
10/10/2023 4:18 PM
10325 - 10324 - Remove MHV Outer Connector Shell; Remark:
Procedure Step
Published
11/18/2023 2:45 PM
10324 - Remove MHV Outer Connector Shell
Instruction
Published
11/18/2023 2:45 PM
9586 - 9547 - Remove MHV outer connector shell; Remark:9548
Procedure Step
Published
10/11/2023 8:04 AM
9545 - Caution : Oils from skin may contaminate the insulating surfaces. Either lint-free cott...
Annotation
Published
10/10/2023 3:51 PM
9604 - Caution : Avoid tearing or binding the rubber O-ring at the base of the connector shell...
Annotation
Published
10/11/2023 11:09 AM
9547 - Remove MHV outer connector shell
Instruction
Published
10/10/2023 4:19 PM
9548 - Use adjustable wrench. Loosen and unscrew connector shell.
Remark
Published
04/13/2025 6:08 PM
9587 - 9549 - Confirm O-ring is positioned above threaded surface and undamaged; Remark:9550
Procedure Step
Published
10/11/2023 8:05 AM
9549 - Confirm O-ring is positioned above threaded surface and undamaged
Instruction
Published
10/10/2023 8:27 PM
9550 - The O-ring size is 0.79 mm (0.031 in.) cross section by 19.69 mm (0.775 in.) ...
Remark
Published
10/10/2023 8:30 PM
10329 - 10328 - Remove Teflon Insulator Ring; Remark:
Procedure Step
Published
11/18/2023 2:55 PM
10328 - Remove Teflon Insulator Ring
Instruction
Published
11/18/2023 2:55 PM
9588 - 9551 - Remove Teflon insulator ring from ceramic core insulator; Remark:9552
Procedure Step
Published
10/11/2023 8:05 AM
9573 - Caution : Do not bend or twist the high voltage wire lead.
Annotation
Published
10/10/2023 10:12 PM
9551 - Remove Teflon insulator ring from ceramic core insulator
Instruction
Published
10/10/2023 8:38 PM
9552 - Carefully pull Teflon insulator ring along the tube axis
Remark
Published
04/13/2025 6:07 PM
10327 - 10326 - Inspect Neutron Tube Insulator; Remark:
Procedure Step
Published
11/18/2023 2:56 PM
10326 - Inspect Neutron Tube Insulator
Instruction
Published
11/18/2023 2:56 PM
9589 - 9553 - Examine surface condition of neutron tube insulator; Remark:9554
Procedure Step
Published
04/13/2025 6:15 PM
9553 - Examine surface condition of neutron tube insulator
Instruction
Published
04/13/2025 6:07 PM
9554 - Questionable insulator
Remark
Published
10/10/2023 9:37 PM
9555 - Typical insulator
Remark
Published
04/13/2025 6:07 PM
9590 - 9556 - Clean Insulator Core and Ring; Remark:
Procedure Step
Published
10/11/2023 8:12 AM
9556 - Clean Insulator Core and Ring
Instruction
Published
10/10/2023 9:40 PM
9591 - 9557 - Rinse ceramic and Teflon insulators; Remark:9558
Procedure Step
Published
04/13/2025 6:15 PM
9559 - Warning : Use nitrile gloves as sensitive skin may react to the alcohol
Annotation
Published
10/10/2023 9:52 PM
9560 - Caution : For quality check, spray alcohol on a piece of clean glass and let evaporate....
Annotation
Published
10/10/2023 9:54 PM
9557 - Rinse ceramic and Teflon insulators
Instruction
Published
04/13/2025 6:07 PM
9558 - Using a stream spray of alcohol, coat insulators and allow to evaporate.&nbsp...
Remark
Published
10/10/2023 9:49 PM
9592 - 9561 - Wipe insulator; Remark:9562
Procedure Step
Published
10/11/2023 8:14 AM
9561 - Wipe insulator
Instruction
Published
10/10/2023 9:54 PM
9562 - Sweep surfaces with cottom swab, or lint-free cloth soaked in alcohol.
Remark
Published
11/18/2023 3:17 PM
10332 - Continue to sweep and rinse until dust particles no longer appear on the swab...
Remark
Published
11/18/2023 3:18 PM
9593 - 9563 - Inspect for and remove cotton fibers; Remark:9564
Procedure Step
Published
10/11/2023 8:15 AM
9563 - Inspect for and remove cotton fibers
Instruction
Published
10/10/2023 10:01 PM
9564 - Remove cotton fibers deposited in insulator areas using tweezers.
Remark
Published
04/13/2025 6:06 PM
9594 - 9566 - Dry insulators; Remark:9567
Procedure Step
Published
10/11/2023 8:16 AM
9565 - Caution : Heating of the detector tube shall not exceed 100°C.
Annotation
Published
10/10/2023 10:05 PM
9566 - Dry insulators
Instruction
Published
10/10/2023 10:05 PM
9567 - Allow components to air dry.
Remark
Published
10/10/2023 10:06 PM
9595 - 9568 - Clean connector shell; Remark:9569
Procedure Step
Published
10/11/2023 8:16 AM
9568 - Clean connector shell
Instruction
Published
10/10/2023 10:06 PM
9569 - The interior of the narrow-size barrel is the primary contact surface to clea...
Remark
Published
10/10/2023 10:09 PM
7279 - 7249 - Return equipment to normal operating condition; Remark:
Procedure Step
Published
04/27/2023 4:13 PM
7249 - Return equipment to normal operating condition
Instruction
Published
04/08/2025 3:22 PM
9597 - 9571 - Confirm O-ring is in place; Remark:9572
Procedure Step
Published
10/11/2023 8:18 AM
9571 - Confirm O-ring is in place
Instruction
Published
10/10/2023 10:10 PM
9572 - No lubrication is necessary.
Remark
Published
10/10/2023 10:12 PM
9598 - 9574 - Reinstall ring insulator; Remark:9575
Procedure Step
Published
04/13/2025 6:15 PM
9574 - Reinstall ring insulator
Instruction
Published
04/13/2025 6:06 PM
9575 - Slide ring insulator over core insulator and high voltage wire lead.
Remark
Published
04/13/2025 6:06 PM
9599 - 9577 - Screw connector shell in place; Remark:9578
Procedure Step
Published
10/11/2023 8:19 AM
9576 - Note : Carefully place threads to avoid cross-threading of shell with the tube wall....
Annotation
Published
10/10/2023 10:17 PM
9577 - Screw connector shell in place
Instruction
Published
10/10/2023 10:17 PM
9578 - Screw connector shell until finger tight.
Remark
Published
04/13/2025 6:05 PM
10331 - 10330 - Test detector tube in an RPM or text fixture when possible; Remark:
Procedure Step
Published
11/18/2023 3:12 PM
10330 - Test detector tube in an RPM or text fixture when possible
Instruction
Published
11/18/2023 3:12 PM
322 - 321 - Document maintenance actions; Remark:
Procedure Step
Published
06/17/2021 9:49 AM
321 - Document maintenance actions
Instruction
Published
04/21/2025 11:19 AM
2869 - 2585 - Document maintenance performed; Remark:2866
Procedure Step
Published
06/18/2021 5:58 PM
2585 - Document maintenance performed
Instruction
Published
07/09/2021 12:15 PM
2866 - Record observations, times, and results for the maintenance report.
Remark
Published
04/21/2025 11:39 AM
4706 - 4705 - Submit report; Remark:4864
Procedure Step
Published
06/29/2022 9:50 AM
4705 - Submit report
Instruction
Published
06/29/2022 9:50 AM
4864 - As specified by management or contractual obligations.
Remark
Published
07/28/2022 1:36 PM
Corrective Maintenance Procedure
Document Type
Published
03/02/2020 3:32 PM
hours
Duration
Published
05/26/2022 11:45 AM
Upon neutron detector tube failure
Frequency
Published
10/11/2023 10:33 AM
Caution
Annotation Type
Published
03/02/2020 3:24 PM
Warning
Annotation Type
Published
03/02/2020 3:25 PM
Note
Annotation Type
Published
03/02/2020 3:25 PM
Technician 1
Skill Level
Published
05/14/2020 2:56 PM
Adjustable wrench
Replacement Parts
Published
06/02/2023 10:08 PM
Tweezers
Tools
Published
08/30/2022 4:28 PM
Safety glasses if required
Replacement Parts
Published
06/20/2023 4:47 PM
Neutron Tube SN Location
படம்
Published
10/10/2023 4:13 PM
Neutron Tube Serial Number Location
படம்
Published
10/10/2023 4:14 PM
Neutron O-ring
படம்
Published
10/10/2023 8:30 PM
Neutron Tube Axis
படம்
Published
10/10/2023 8:37 PM
Neutron Questionable Insulator
படம்
Published
10/10/2023 9:32 PM
Neutron Typical Insulator
படம்
Published
10/10/2023 9:34 PM
Wipe Neutron Insulator
படம்
Published
10/10/2023 9:56 PM
Neutron Tube Shell
படம்
Published
10/10/2023 10:07 PM
Neutron Insulator
படம்
Published
10/10/2023 10:14 PM

RPM ELK Siren Replacement

Last Updated: 04/23/2025 1:42 AM

The following table lists all the components that make up the document.

Title Type Status Last Updated
Rapiscan VM-250 Vehicle Monitor
Device
Published
10/14/2024 9:50 AM
Rapiscan TM-850 Rail Monitor
Device
Published
09/18/2024 10:28 AM
8468 - 1401 - Establish Initial Conditions; Remark:
Procedure Step
Published
09/16/2023 4:47 PM
1401 - Establish Initial Conditions
Instruction
Published
09/30/2022 3:14 PM
8490 - 7592 - Inform system operators; Remark:
Procedure Step
Published
09/16/2023 8:49 PM
7592 - Inform system operators
Instruction
Published
06/29/2023 3:20 PM
8221 - 7676 - Brief system operators on expected work, duration, anticipated alarms, and fa...; Remark:
Procedure Step
Published
09/01/2023 9:26 PM
7676 - Brief system operators on expected work, duration, anticipated alarms, and fa...
Instruction
Published
07/01/2023 11:39 PM
10267 - 7967 - Close lane and set up barriers or establish a safety watch; Remark:7571
Procedure Step
Published
11/10/2023 1:41 PM
7678 - Warning : Traffic should temporarily be rerouted or halted during conduction of this pr...
Annotation
Published
07/03/2023 10:23 AM
7967 - Close lane and set up barriers or establish a safety watch
Instruction
Published
07/12/2023 12:41 AM
7571 - Use orange safety cones or equivalent based on site-specific safety practices...
Remark
Published
06/20/2023 4:42 PM
10268 - 9235 - Open Control pillar RPM door; Remark:
Procedure Step
Published
11/10/2023 1:42 PM
9235 - Open Control pillar RPM door
Instruction
Published
10/03/2023 12:03 PM
7270 - 7235 - Power off RPM; Remark:7236
Procedure Step
Published
09/01/2023 7:57 PM
7235 - Power off RPM
Instruction
Published
04/24/2023 12:30 PM
7236 - Move LD-260 switch to OFF position. The PWR ON
Remark
Published
04/27/2023 4:25 PM
8748 - 8747 - Disconnect ELK Siren Wiring; Remark:
Procedure Step
Published
09/24/2023 10:25 PM
8747 - Disconnect ELK Siren Wiring
Instruction
Published
09/24/2023 10:24 PM
8803 - 8673 - Locate terminal block TB4; Remark:8674
Procedure Step
Published
09/25/2023 9:59 AM
7792 - Note : It is good engineering practice to ensure all cables and connectors are label...
Annotation
Published
07/07/2023 2:17 PM
8673 - Locate terminal block TB4
Instruction
Published
09/24/2023 10:02 AM
8674 - For vehicle monitors: Open the upper RPM door
Remark
Published
09/24/2023 9:58 AM
8751 - 8749 - Disconnect wires from terminal block TB4; Remark:8750
Procedure Step
Published
09/24/2023 10:31 PM
8749 - Disconnect wires from terminal block TB4
Instruction
Published
09/24/2023 10:28 PM
8750 - Using a flathead screwdriver, disconnect wires: Red wire - ...
Remark
Published
09/24/2023 10:30 PM
8753 - 8678 - Release wiring harness from fasteners; Remark:8752
Procedure Step
Published
04/13/2025 6:16 PM
8678 - Release wiring harness from fasteners
Instruction
Published
04/13/2025 6:10 PM
8752 - Using cutter pliers, remove associated fasteners from TB4 Pin 8
Remark
Published
09/24/2023 10:45 PM
8755 - 8754 - Uninstall Faulty ELK Siren and Housing; Remark:
Procedure Step
Published
09/24/2023 10:47 PM
8754 - Uninstall Faulty ELK Siren and Housing
Instruction
Published
09/24/2023 10:46 PM
8758 - 8756 - Remove screw located on bottom of ELK siren housing; Remark:8757
Procedure Step
Published
09/24/2023 10:50 PM
8756 - Remove screw located on bottom of ELK siren housing
Instruction
Published
09/24/2023 10:47 PM
8757 - Turn screw counterclockwise using an 11 mm wrench.
Remark
Published
09/24/2023 10:49 PM
8761 - 8759 - Remove outer casing of ELK siren; Remark:8760
Procedure Step
Published
09/24/2023 10:52 PM
8759 - Remove outer casing of ELK siren
Instruction
Published
09/24/2023 10:50 PM
8760 - Lower outer casing approximately ½” (12 mm), pull casing away from door ap...
Remark
Published
09/24/2023 10:51 PM
8764 - 8762 - Remove ELK siren; Remark:8763
Procedure Step
Published
09/24/2023 10:55 PM
8762 - Remove ELK siren
Instruction
Published
09/24/2023 10:52 PM
8763 - Pull the siren away from the housing assembly. Ensure when removing to pull s...
Remark
Published
09/24/2023 10:54 PM
8766 - 8765 - Carefully pull ELK siren thorugh door without losing grommet; Remark:
Procedure Step
Published
09/24/2023 10:57 PM
8765 - Carefully pull ELK siren thorugh door without losing grommet
Instruction
Published
09/24/2023 10:57 PM
8770 - 8767 - Remove screws and nuts; Remark:8769
Procedure Step
Published
09/24/2023 11:02 PM
8768 - Caution : While removing the hardware, the enclosure mount will come loose. Take care n...
Annotation
Published
09/24/2023 10:58 PM
8767 - Remove screws and nuts
Instruction
Published
09/24/2023 10:58 PM
8769 - Using an adjustable wrench, hold nuts on the inside of the door while using a...
Remark
Published
09/24/2023 11:01 PM
8771 - 8693 - Remove residue off RPM door; Remark:
Procedure Step
Published
09/24/2023 11:04 PM
8693 - Remove residue off RPM door
Instruction
Published
09/24/2023 1:22 PM
3397 - 3395 - Label faulty component; Remark:3396
Procedure Step
Published
07/21/2024 6:59 AM
3395 - Label faulty component
Instruction
Published
08/07/2021 11:07 AM
3396 - Use tag or tape. Include date of removal, description of failure symptoms, co...
Remark
Published
08/09/2021 11:35 AM
8773 - 8772 - Install New ELK Siren Housing and Siren; Remark:
Procedure Step
Published
09/24/2023 11:07 PM
8772 - Install New ELK Siren Housing and Siren
Instruction
Published
09/24/2023 11:06 PM
8776 - 8774 - Attach new ELK siren mount; Remark:
Procedure Step
Published
09/24/2023 11:10 PM
8774 - Attach new ELK siren mount
Instruction
Published
09/24/2023 11:08 PM
8777 - 8775 - Apply a light amount of silicone around nuts on back side of door; Remark:
Procedure Step
Published
09/24/2023 11:11 PM
8701 - Warning : Use protective gloves when handling silicone.
Annotation
Published
09/24/2023 1:50 PM
8775 - Apply a light amount of silicone around nuts on back side of door
Instruction
Published
09/24/2023 11:09 PM
8780 - 8778 - Feed ELK siren wires through grommet located in door; Remark:8779
Procedure Step
Published
09/24/2023 11:19 PM
8778 - Feed ELK siren wires through grommet located in door
Instruction
Published
09/24/2023 11:17 PM
8779 - ELK Siren Wires
Remark
Published
09/24/2023 11:18 PM
8783 - 8781 - Slide new ELK siren onto ELK siren housing tab; Remark:8782
Procedure Step
Published
09/24/2023 11:22 PM
8781 - Slide new ELK siren onto ELK siren housing tab
Instruction
Published
09/24/2023 11:19 PM
8782 - ELK Siren Housing Tab
Remark
Published
09/24/2023 11:21 PM
8785 - 8784 - Apply a light amount of silicone around wires and grommet on back side of doo...; Remark:
Procedure Step
Published
09/24/2023 11:23 PM
8784 - Apply a light amount of silicone around wires and grommet on back side of doo...
Instruction
Published
09/24/2023 11:22 PM
8788 - 8786 - Reinstall ELK siren housing outer case; Remark:8787
Procedure Step
Published
09/24/2023 11:26 PM
8786 - Reinstall ELK siren housing outer case
Instruction
Published
09/24/2023 11:24 PM
8787 - The tabs on the outer casing must fit in the U-shaped slot on the housing ass...
Remark
Published
09/24/2023 11:25 PM
8791 - 8789 - Install screw located on bottom of ELK siren housing.; Remark:8790
Procedure Step
Published
09/24/2023 11:28 PM
8789 - Install screw located on bottom of ELK siren housing.
Instruction
Published
09/24/2023 11:27 PM
8790 - ELK Siren Bottom Screw
Remark
Published
09/24/2023 11:27 PM
8794 - 8793 - Reconnect ELK Siren Wiring; Remark:
Procedure Step
Published
09/24/2023 11:31 PM
8793 - Reconnect ELK Siren Wiring
Instruction
Published
09/24/2023 11:31 PM
8792 - 8673 - Locate terminal block TB4; Remark:8674
Procedure Step
Published
09/24/2023 11:30 PM
8797 - 8795 - Connect wires to terminal block TB4; Remark:8796
Procedure Step
Published
09/24/2023 11:34 PM
8795 - Connect wires to terminal block TB4
Instruction
Published
09/24/2023 11:31 PM
8796 - Using a flathead screwdriver, connect wires: Red wire - Pin...
Remark
Published
09/24/2023 11:33 PM
8799 - 8714 - Add wire fasteners where removed; Remark:8798
Procedure Step
Published
09/24/2023 11:37 PM
8714 - Add wire fasteners where removed
Instruction
Published
09/24/2023 2:16 PM
8798 - Adding ELK Siren Wiring Fasteners
Remark
Published
09/24/2023 11:37 PM
7279 - 7249 - Return equipment to normal operating condition; Remark:
Procedure Step
Published
04/27/2023 4:13 PM
7249 - Return equipment to normal operating condition
Instruction
Published
04/08/2025 3:22 PM
8503 - 7250 - Power on RPM; Remark:7251
Procedure Step
Published
09/16/2023 9:00 PM
7250 - Power on RPM
Instruction
Published
05/01/2023 8:31 AM
7251 - Move LD-260 switch to ON position. The LED PWR ON
Remark
Published
05/10/2023 3:14 PM
8801 - 8800 - Listen for the siren to activate; Remark:
Procedure Step
Published
04/13/2025 6:15 PM
8800 - Listen for the siren to activate
Instruction
Published
04/13/2025 6:09 PM
8670 - 319 - Perform operational test; Remark:8669
Procedure Step
Published
04/08/2025 2:20 PM
319 - Perform operational test
Instruction
Published
06/10/2021 8:31 PM
8669 - DET-RPM-RAP-RM03, RPM Operational Testing
Remark
Published
09/20/2023 4:18 PM
8506 - 7254 - Confirm network connection; Remark:7255
Procedure Step
Published
09/24/2023 3:34 PM
7254 - Confirm network connection
Instruction
Published
04/27/2023 2:22 PM
7255 - Contact operators to confirm communications have been reestablished between RPM ...
Remark
Published
05/10/2023 3:15 PM
8507 - 7256 - Close and lock all RPM doors; Remark:
Procedure Step
Published
09/24/2023 3:35 PM
7256 - Close and lock all RPM doors
Instruction
Published
04/27/2023 2:21 PM
7842 - 7820 - Inform system operators upon completion of maintenance action; Remark:
Procedure Step
Published
07/07/2023 11:15 PM
7820 - Inform system operators upon completion of maintenance action
Instruction
Published
07/07/2023 10:02 PM
322 - 321 - Document maintenance actions; Remark:
Procedure Step
Published
06/17/2021 9:49 AM
321 - Document maintenance actions
Instruction
Published
04/21/2025 11:19 AM
2869 - 2585 - Document maintenance performed; Remark:2866
Procedure Step
Published
06/18/2021 5:58 PM
2585 - Document maintenance performed
Instruction
Published
07/09/2021 12:15 PM
2866 - Record observations, times, and results for the maintenance report.
Remark
Published
04/21/2025 11:39 AM
4706 - 4705 - Submit report; Remark:4864
Procedure Step
Published
06/29/2022 9:50 AM
4705 - Submit report
Instruction
Published
06/29/2022 9:50 AM
4864 - As specified by management or contractual obligations.
Remark
Published
07/28/2022 1:36 PM
Corrective Maintenance Procedure
Document Type
Published
03/02/2020 3:32 PM
Upon failure of ELK siren
Frequency
Published
09/25/2023 9:49 AM
Warning
Annotation Type
Published
03/02/2020 3:25 PM
Note
Annotation Type
Published
03/02/2020 3:25 PM
Caution
Annotation Type
Published
03/02/2020 3:24 PM
Technician 1
Skill Level
Published
05/14/2020 2:56 PM
Small slotted (flathead) screwdriver
Tools
Published
09/11/2020 11:23 AM
Medium Phillips (PH2) screwdriver
Tools
Published
04/24/2020 4:40 PM
Adjustable wrench
Replacement Parts
Published
06/02/2023 10:08 PM
Wire cutter pliers
Tools
Published
10/27/2022 1:20 PM
Gloves
Replacement Parts
Published
05/10/2023 3:28 PM
LD-260 Disconnect Switch Power Off
படம்
Published
04/24/2023 12:49 PM
TB4 Siren Wiring
படம்
Published
09/24/2023 10:30 PM
ELK Siren Screw
படம்
Published
09/24/2023 10:48 PM
Remove ELK Siren
படம்
Published
09/24/2023 10:53 PM
ELK Siren Mount
படம்
Published
09/24/2023 10:59 PM
ELK Siren Mount Nuts
படம்
Published
09/24/2023 11:00 PM
ELK Siren Wires
படம்
Published
09/24/2023 11:18 PM
ELK Siren Housing Tab
படம்
Published
09/24/2023 11:20 PM
ELK Siren Housing
படம்
Published
09/24/2023 11:25 PM
ELK Siren Wiring Fasteners
படம்
Published
09/24/2023 11:36 PM
LD-260 Disconnect Switch Power On
படம்
Published
05/04/2023 3:37 PM

RPM Banner IR Occupancy Sensor Replacement

Last Updated: 04/23/2025 1:42 AM

The following table lists all the components that make up the document.

Title Type Status Last Updated
Rapiscan VM-250 Vehicle Monitor
Device
Published
10/14/2024 9:50 AM
Rapiscan TM-850 Rail Monitor
Device
Published
09/18/2024 10:28 AM
8468 - 1401 - Establish Initial Conditions; Remark:
Procedure Step
Published
09/16/2023 4:47 PM
1401 - Establish Initial Conditions
Instruction
Published
09/30/2022 3:14 PM
7268 - 7231 - Close lane; Remark:7233
Procedure Step
Published
04/27/2023 7:01 PM
9053 - Warning : Traffic should temporarily be rerouted or halted during conduction of this pr...
Annotation
Published
09/27/2023 9:09 AM
7231 - Close lane
Instruction
Published
04/18/2023 1:00 PM
7233 - Use orange safety (traffic control) cones to setup barriers. Practice establi...
Remark
Published
04/24/2023 12:18 PM
7269 - 7232 - Open RPM door; Remark:7234
Procedure Step
Published
04/27/2023 7:02 PM
7232 - Open RPM door
Instruction
Published
04/18/2023 1:02 PM
7234 - Open all doors needed to access components.
Remark
Published
04/19/2025 7:48 PM
7270 - 7235 - Power off RPM; Remark:7236
Procedure Step
Published
09/01/2023 7:57 PM
7235 - Power off RPM
Instruction
Published
04/24/2023 12:30 PM
7236 - Move LD-260 switch to OFF position. The PWR ON
Remark
Published
04/27/2023 4:25 PM
8623 - 8613 - Uninstall Faulty Sensor; Remark:
Procedure Step
Published
09/19/2023 12:06 PM
8613 - Uninstall Faulty Sensor
Instruction
Published
09/19/2023 11:40 AM
8624 - 8614 - Locate infrared sensors; Remark:8615
Procedure Step
Published
09/19/2023 5:39 PM
8614 - Locate infrared sensors
Instruction
Published
09/19/2023 11:41 AM
8615 - Typical sensor locations are as follows: Control pillar hou...
Remark
Published
09/19/2023 11:43 AM
8625 - 8617 - Disconnect applicable infrared sensors; Remark:8618
Procedure Step
Published
09/19/2023 12:08 PM
8617 - Disconnect applicable infrared sensors
Instruction
Published
09/19/2023 11:49 AM
8618 - To disconnect sensor cable, turn collar counterclockwise and pull away from s...
Remark
Published
09/19/2023 11:51 AM
8626 - 8619 - Unscrew mounting nut; Remark:8620
Procedure Step
Published
09/19/2023 12:09 PM
8619 - Unscrew mounting nut
Instruction
Published
09/19/2023 11:59 AM
8620 - Rotate threaded nut counterclockwise. It may be necessary to hold the infrare...
Remark
Published
09/19/2023 11:58 AM
8627 - 8621 - Remove sensor from back of door; Remark:8622
Procedure Step
Published
09/19/2023 12:09 PM
8621 - Remove sensor from back of door
Instruction
Published
09/19/2023 12:01 PM
8622 - Removal of infrared sensor
Remark
Published
09/19/2023 12:03 PM
8660 - 8658 - Retain sensor O-ring; Remark:8659
Procedure Step
Published
09/19/2023 5:56 PM
8658 - Retain sensor O-ring
Instruction
Published
09/19/2023 5:55 PM
8659 - Retain Sensor O-ring
Remark
Published
09/19/2023 5:55 PM
3397 - 3395 - Label faulty component; Remark:3396
Procedure Step
Published
07/21/2024 6:59 AM
3395 - Label faulty component
Instruction
Published
08/07/2021 11:07 AM
3396 - Use tag or tape. Include date of removal, description of failure symptoms, co...
Remark
Published
08/09/2021 11:35 AM
8641 - 8628 - Install New Sensor; Remark:
Procedure Step
Published
09/19/2023 4:09 PM
8628 - Install New Sensor
Instruction
Published
09/19/2023 12:35 PM
8642 - 8629 - Verify replacement sensor matches function and color of sensor previously rem...; Remark:8630
Procedure Step
Published
09/19/2023 4:10 PM
8629 - Verify replacement sensor matches function and color of sensor previously rem...
Instruction
Published
09/19/2023 12:36 PM
8630 - Infrared sensor identification
Remark
Published
09/19/2023 12:48 PM
8643 - 8631 - Remove nut closest to sensor face; Remark:8632
Procedure Step
Published
09/19/2023 4:11 PM
8631 - Remove nut closest to sensor face
Instruction
Published
09/19/2023 12:48 PM
8632 - Infrared Nut
Remark
Published
09/19/2023 12:50 PM
8644 - 8633 - Add retained O-ring; Remark:8634
Procedure Step
Published
09/19/2023 4:12 PM
8633 - Add retained O-ring
Instruction
Published
09/19/2023 3:52 PM
8634 - Infrared Sensor O-ring
Remark
Published
09/19/2023 3:55 PM
8645 - 8635 - Mount new infrared sensor; Remark:8636
Procedure Step
Published
09/19/2023 4:13 PM
8635 - Mount new infrared sensor
Instruction
Published
09/19/2023 3:57 PM
8636 - Insert sensor through hole on the back side of door.
Remark
Published
09/19/2023 4:01 PM
8646 - 8638 - Add outside nut to front and hand tighten; Remark:8639
Procedure Step
Published
09/19/2023 4:14 PM
8637 - Note : The nut on the outside should be flush with the sensor.
Annotation
Published
09/19/2023 4:01 PM
8638 - Add outside nut to front and hand tighten
Instruction
Published
09/19/2023 4:02 PM
8639 - Use the adjustable wrench to snug the nut up slightly, just enough for the ga...
Remark
Published
09/19/2023 4:05 PM
8647 - 8661 - Reconnect applicable cable previously removed in Step 4-6; Remark:8559
Procedure Step
Published
09/19/2023 4:15 PM
5553 - Caution : Correct placement of connectors and wiring is critical to proper operation.
Annotation
Published
10/28/2022 2:19 PM
8661 - Reconnect applicable cable previously removed in Step 4-4
Instruction
Published
09/19/2023 6:14 PM
8559 - To reconnect sensor cable, align connectors, push towards sensor, and turn co...
Remark
Published
09/29/2023 12:05 PM
7279 - 7249 - Return equipment to normal operating condition; Remark:
Procedure Step
Published
04/27/2023 4:13 PM
7249 - Return equipment to normal operating condition
Instruction
Published
04/08/2025 3:22 PM
8503 - 7250 - Power on RPM; Remark:7251
Procedure Step
Published
09/16/2023 9:00 PM
7250 - Power on RPM
Instruction
Published
05/01/2023 8:31 AM
7251 - Move LD-260 switch to ON position. The LED PWR ON
Remark
Published
05/10/2023 3:14 PM
7281 - 7252 - Verify RPM start-up; Remark:7253
Procedure Step
Published
04/20/2025 3:26 PM
7252 - Verify RPM start-up
Instruction
Published
04/27/2023 2:23 PM
7253 - RPM will perform a power on self-test (POST) and collect a background radiati...
Remark
Published
05/10/2023 3:14 PM
8654 - 8648 - Verify SC-770 display shows OCCUPIED when infrared beams are...; Remark:8651
Procedure Step
Published
09/19/2023 4:52 PM
8648 - Verify SC-770 display shows OCCUPIED when infrared beams are...
Instruction
Published
09/19/2023 4:23 PM
8651 - SC-770 Occupied
Remark
Published
09/19/2023 4:30 PM
8655 - 8649 - Test sensors independently; Remark:8650
Procedure Step
Published
09/19/2023 4:53 PM
8649 - Test sensors independently
Instruction
Published
09/19/2023 4:24 PM
8650 - Disconnect one receiver cable, shut door, and clear sensors for five (5) seco...
Remark
Published
09/19/2023 4:28 PM
8656 - 8648 - Verify SC-770 display shows OCCUPIED when infrared beams are...; Remark:8651
Procedure Step
Published
09/19/2023 4:54 PM
8653 - 8652 - Repeat steps 4-4 through 4-6 for other receiver sensors.; Remark:
Procedure Step
Published
04/13/2025 6:16 PM
8652 - Repeat steps 4-4 through 4-6 for other receiver sensors.
Instruction
Published
04/13/2025 6:11 PM
7282 - 7254 - Confirm network connection; Remark:7255
Procedure Step
Published
04/27/2023 4:15 PM
7254 - Confirm network connection
Instruction
Published
04/27/2023 2:22 PM
7255 - Contact operators to confirm communications have been reestablished between RPM ...
Remark
Published
05/10/2023 3:15 PM
7283 - 7256 - Close and lock all RPM doors; Remark:
Procedure Step
Published
09/01/2023 11:45 PM
7256 - Close and lock all RPM doors
Instruction
Published
04/27/2023 2:21 PM
7842 - 7820 - Inform system operators upon completion of maintenance action; Remark:
Procedure Step
Published
07/07/2023 11:15 PM
7820 - Inform system operators upon completion of maintenance action
Instruction
Published
07/07/2023 10:02 PM
322 - 321 - Document maintenance actions; Remark:
Procedure Step
Published
06/17/2021 9:49 AM
321 - Document maintenance actions
Instruction
Published
04/21/2025 11:19 AM
2869 - 2585 - Document maintenance performed; Remark:2866
Procedure Step
Published
06/18/2021 5:58 PM
2585 - Document maintenance performed
Instruction
Published
07/09/2021 12:15 PM
2866 - Record observations, times, and results for the maintenance report.
Remark
Published
04/21/2025 11:39 AM
4706 - 4705 - Submit report; Remark:4864
Procedure Step
Published
06/29/2022 9:50 AM
4705 - Submit report
Instruction
Published
06/29/2022 9:50 AM
4864 - As specified by management or contractual obligations.
Remark
Published
07/28/2022 1:36 PM
Corrective Maintenance Procedure
Document Type
Published
03/02/2020 3:32 PM
30 minutes
Duration
Published
04/01/2020 11:35 AM
If system is locked in continuous occupancy or speed indication does not function
Frequency
Published
09/19/2023 5:28 PM
Warning
Annotation Type
Published
03/02/2020 3:25 PM
Note
Annotation Type
Published
03/02/2020 3:25 PM
Caution
Annotation Type
Published
03/02/2020 3:24 PM
Technician 1
Skill Level
Published
05/14/2020 2:56 PM
Keys to access RPM
Replacement Parts
Published
04/27/2023 6:56 PM
Adjustable wrench
Replacement Parts
Published
06/02/2023 10:08 PM
Ladder: 2 meters, 6 feet tall; non-conducting
Replacement Parts
Published
09/01/2023 9:34 PM
Reflective safety vest if required
Replacement Parts
Published
06/20/2023 4:47 PM
LD-260 Disconnect Switch Power Off
படம்
Published
04/24/2023 12:49 PM
Remove Infrared Sensor Nut
படம்
Published
09/19/2023 11:57 AM
Mount Infrared Sensors
படம்
Published
09/19/2023 5:51 PM
Retained Infrared O-ring
படம்
Published
09/19/2023 5:44 PM
Infrared Sensor Identification
படம்
Published
09/19/2023 12:39 PM
Outside Nut of Infrared Sensor
படம்
Published
09/19/2023 12:49 PM
Tighten Infrared Sensor Nut
படம்
Published
09/19/2023 4:03 PM
Infrared Connection
படம்
Published
09/29/2023 12:02 PM
Infrared Cable Installation
படம்
Published
09/17/2023 10:12 PM
Infrared Sensor Cable
படம்
Published
09/17/2023 10:13 PM
LD-260 Disconnect Switch Power On
படம்
Published
05/04/2023 3:37 PM
SC-770 Occupied
படம்
Published
09/19/2023 4:30 PM

RPM Sonalert Module Replacement

Last Updated: 04/23/2025 1:42 AM

The following table lists all the components that make up the document.

Title Type Status Last Updated
Rapiscan PM-700 Pedestrian Monitor
Device
Published
06/20/2024 11:38 AM
8468 - 1401 - Establish Initial Conditions; Remark:
Procedure Step
Published
09/16/2023 4:47 PM
1401 - Establish Initial Conditions
Instruction
Published
09/30/2022 3:14 PM
8489 - 1401 - Establish Initial Conditions; Remark:
Procedure Step
Published
09/24/2023 9:51 AM
7265 - Warning : Traffic should temporarily be rerouted or halted during this procedure to ens...
Annotation
Published
04/27/2023 1:42 PM
8490 - 7592 - Inform system operators; Remark:
Procedure Step
Published
09/16/2023 8:49 PM
7592 - Inform system operators
Instruction
Published
06/29/2023 3:20 PM
8221 - 7676 - Brief system operators on expected work, duration, anticipated alarms, and fa...; Remark:
Procedure Step
Published
09/01/2023 9:26 PM
7676 - Brief system operators on expected work, duration, anticipated alarms, and fa...
Instruction
Published
07/01/2023 11:39 PM
8492 - 8469 - Uninstall Faulty Sonalert Module; Remark:
Procedure Step
Published
09/16/2023 8:51 PM
8469 - Uninstall Faulty Sonalert Module
Instruction
Published
09/16/2023 10:05 PM
8494 - 8472 - Isolate faulty neutron Sonalert module; Remark:8473
Procedure Step
Published
09/16/2023 8:53 PM
8475 - Note : Sonalert modules produce an audio alert during a Power On Self-Test (POST). P...
Annotation
Published
09/16/2023 5:54 PM
8472 - Isolate faulty neutron Sonalert module
Instruction
Published
09/16/2023 5:30 PM
8473 - The Sonalert below the blue LED is for neutron alarms. It em...
Remark
Published
09/16/2023 5:33 PM
8493 - 8470 - Isolate faulty gamma Sonalert module; Remark:8471
Procedure Step
Published
09/16/2023 8:52 PM
8470 - Isolate faulty gamma Sonalert module
Instruction
Published
09/16/2023 5:30 PM
8471 - The Sonalert below the red LED is for gamma alarms. It emits...
Remark
Published
09/16/2023 5:27 PM
8495 - 8476 - Disconnect wiring from faulty Sonalert module; Remark:8477
Procedure Step
Published
09/16/2023 9:54 PM
7352 - Note : It is good practice to verify all cables and connectors are labeled prior to ...
Annotation
Published
05/03/2023 11:27 AM
8476 - Disconnect wiring from faulty Sonalert module
Instruction
Published
09/16/2023 5:57 PM
8477 - Neutron Sonalert Module
Remark
Published
04/13/2025 5:58 PM
9174 - Gamma Sonalert Module
Remark
Published
04/13/2025 6:09 PM
8496 - 8478 - Unscrew mounting ring; Remark:8479
Procedure Step
Published
09/16/2023 8:55 PM
8478 - Unscrew mounting ring
Instruction
Published
09/16/2023 6:08 PM
8479 - Rotate threaded ring counter-clockwise. It may be necessary to use an adjusta...
Remark
Published
09/16/2023 6:13 PM
8497 - 8480 - Remove faulty Sonalert module; Remark:
Procedure Step
Published
09/16/2023 8:56 PM
8480 - Remove faulty Sonalert module
Instruction
Published
09/16/2023 6:14 PM
3397 - 3395 - Label faulty component; Remark:3396
Procedure Step
Published
07/21/2024 6:59 AM
3395 - Label faulty component
Instruction
Published
08/07/2021 11:07 AM
3396 - Use tag or tape. Include date of removal, description of failure symptoms, co...
Remark
Published
08/09/2021 11:35 AM
8499 - 8481 - Install New Sonalert Module; Remark:
Procedure Step
Published
09/16/2023 8:57 PM
8481 - Install New Sonalert Module
Instruction
Published
09/16/2023 6:18 PM
8500 - 8482 - Mount new Sonalert module; Remark:8483
Procedure Step
Published
09/16/2023 8:58 PM
8482 - Mount new Sonalert module
Instruction
Published
09/16/2023 6:19 PM
8483 - Place Sonalert module through hole in door and install the threaded ring.&nbs...
Remark
Published
09/16/2023 6:20 PM
8501 - 8484 - Connect wires to Sonalert module; Remark:9176
Procedure Step
Published
09/16/2023 8:59 PM
7263 - Caution : Correct placement of connectors and wiring is critical to proper operation.
Annotation
Published
04/24/2023 2:32 PM
8484 - Connect wires to Sonalert module
Instruction
Published
09/16/2023 6:22 PM
9176 - Neutron alarm Sonalert connections: Positive termi...
Remark
Published
09/28/2023 2:19 PM
9175 - Gamma alarm Sonalert connections: Positive termina...
Remark
Published
09/28/2023 2:04 PM
7279 - 7249 - Return equipment to normal operating condition; Remark:
Procedure Step
Published
04/27/2023 4:13 PM
7249 - Return equipment to normal operating condition
Instruction
Published
04/08/2025 3:22 PM
8503 - 7250 - Power on RPM; Remark:7251
Procedure Step
Published
09/16/2023 9:00 PM
7250 - Power on RPM
Instruction
Published
05/01/2023 8:31 AM
7251 - Move LD-260 switch to ON position. The LED PWR ON
Remark
Published
05/10/2023 3:14 PM
8504 - 8486 - Verify operation of new Sonalert; Remark:8487
Procedure Step
Published
09/16/2023 10:56 PM
8486 - Verify operation of new Sonalert
Instruction
Published
09/16/2023 6:55 PM
8487 - Both neutron and gamma Sonalert modules produce an audio alert during Power O...
Remark
Published
09/16/2023 7:00 PM
8506 - 7254 - Confirm network connection; Remark:7255
Procedure Step
Published
09/24/2023 3:34 PM
7254 - Confirm network connection
Instruction
Published
04/27/2023 2:22 PM
7255 - Contact operators to confirm communications have been reestablished between RPM ...
Remark
Published
05/10/2023 3:15 PM
8507 - 7256 - Close and lock all RPM doors; Remark:
Procedure Step
Published
09/24/2023 3:35 PM
7256 - Close and lock all RPM doors
Instruction
Published
04/27/2023 2:21 PM
7842 - 7820 - Inform system operators upon completion of maintenance action; Remark:
Procedure Step
Published
07/07/2023 11:15 PM
7820 - Inform system operators upon completion of maintenance action
Instruction
Published
07/07/2023 10:02 PM
322 - 321 - Document maintenance actions; Remark:
Procedure Step
Published
06/17/2021 9:49 AM
321 - Document maintenance actions
Instruction
Published
04/21/2025 11:19 AM
2869 - 2585 - Document maintenance performed; Remark:2866
Procedure Step
Published
06/18/2021 5:58 PM
2585 - Document maintenance performed
Instruction
Published
07/09/2021 12:15 PM
2866 - Record observations, times, and results for the maintenance report.
Remark
Published
04/21/2025 11:39 AM
4706 - 4705 - Submit report; Remark:4864
Procedure Step
Published
06/29/2022 9:50 AM
4705 - Submit report
Instruction
Published
06/29/2022 9:50 AM
4864 - As specified by management or contractual obligations.
Remark
Published
07/28/2022 1:36 PM
Corrective Maintenance Procedure
Document Type
Published
03/02/2020 3:32 PM
Upon failure of Sonalert module
Frequency
Published
09/16/2023 9:36 PM
Warning
Annotation Type
Published
03/02/2020 3:25 PM
Note
Annotation Type
Published
03/02/2020 3:25 PM
Caution
Annotation Type
Published
03/02/2020 3:24 PM
Technician 2
Skill Level
Published
04/09/2020 1:17 AM
Keys to access RPM
Replacement Parts
Published
04/27/2023 6:56 PM
Medium Phillips (PH2) screwdriver
Tools
Published
04/24/2020 4:40 PM
Adjustable wrench
Replacement Parts
Published
06/02/2023 10:08 PM
Orange/yellow safety vest
Replacement Parts
Published
04/27/2023 6:56 PM
Safety shoes
Replacement Parts
Published
04/27/2023 6:56 PM
Gloves
Replacement Parts
Published
05/10/2023 3:28 PM
Protective headwear: glasses, hard hat
Replacement Parts
Published
05/10/2023 3:31 PM
Orange traffic cones
Replacement Parts
Published
04/27/2023 6:56 PM
Neutron Alarm
படம்
Published
09/16/2023 5:28 PM
Gamma Sonalert
படம்
Published
09/16/2023 5:26 PM
Neutron Speaker
படம்
Published
09/16/2023 6:01 PM
Gamma Speaker
படம்
Published
09/16/2023 6:00 PM
Unscrew Sonalert Ring
படம்
Published
09/16/2023 6:10 PM
Neutron Terminal
படம்
Published
09/28/2023 2:05 PM
Gamma Terminal.png
படம்
Published
09/16/2023 6:39 PM
LD-260 Disconnect Switch Power On
படம்
Published
05/04/2023 3:37 PM

RPM IXIO-DT1 Occupancy Sensor Replacement

Last Updated: 04/23/2025 1:40 AM

The following table lists all the components that make up the document.

Title Type Status Last Updated
Rapiscan PM-700 Pedestrian Monitor
Device
Published
06/20/2024 11:38 AM
7478 - 1401 - Establish Initial Conditions; Remark:
Procedure Step
Published
09/01/2023 7:48 PM
1401 - Establish Initial Conditions
Instruction
Published
09/30/2022 3:14 PM
7452 - 7231 - Close lane; Remark:7415
Procedure Step
Published
06/02/2023 5:12 PM
7231 - Close lane
Instruction
Published
04/18/2023 1:00 PM
7415 - Re-route pedestrian traffic.
Remark
Published
06/02/2023 1:08 PM
7453 - 7232 - Open RPM door; Remark:7267
Procedure Step
Published
06/02/2023 5:24 PM
7232 - Open RPM door
Instruction
Published
04/18/2023 1:02 PM
7267 - Open all doors needed to access components.
Remark
Published
09/16/2023 4:54 PM
7454 - 7290 - Disable tamper switches; Remark:7416
Procedure Step
Published
06/02/2023 5:25 PM
7290 - Disable tamper switches
Instruction
Published
05/01/2023 8:14 AM
7416 - Use a magnet to disable tamper switches for all open doors. Use adhesive tape...
Remark
Published
06/02/2023 1:18 PM
7270 - 7235 - Power off RPM; Remark:7236
Procedure Step
Published
09/01/2023 7:57 PM
7235 - Power off RPM
Instruction
Published
04/24/2023 12:30 PM
7236 - Move LD-260 switch to OFF position. The PWR ON
Remark
Published
04/27/2023 4:25 PM
7479 - 7417 - Prepare New Occupancy Sensor; Remark:
Procedure Step
Published
06/02/2023 6:13 PM
7417 - Prepare New Occupancy Sensor
Instruction
Published
06/02/2023 1:39 PM
7456 - 7418 - Remove cover from new occupancy sensor; Remark:7419
Procedure Step
Published
06/02/2023 5:27 PM
7418 - Remove cover from new occupancy sensor
Instruction
Published
06/02/2023 1:43 PM
7419 - Use a slotted screwdriver to pry the cover off from the side.
Remark
Published
04/13/2025 5:44 PM
7457 - 7420 - Verify narrow field radar antenna is installed; Remark:7421
Procedure Step
Published
04/13/2025 6:18 PM
7420 - Verify narrow field radar antenna is installed
Instruction
Published
04/13/2025 5:44 PM
7421 - The IXIO-DT1 should come with the narrow field antenna installed.
Remark
Published
06/02/2023 2:14 PM
8901 - If needed, the antenna can be changed. Remove cover. Install narrow field ant...
Remark
Published
09/25/2023 9:51 PM
7480 - 7422 - Uninstall Faulty Occupancy Sensor; Remark:
Procedure Step
Published
06/02/2023 9:42 PM
7422 - Uninstall Faulty Occupancy Sensor
Instruction
Published
06/02/2023 2:16 PM
7458 - 7423 - Remove Cover; Remark:7424
Procedure Step
Published
06/02/2023 5:28 PM
7423 - Remove Cover
Instruction
Published
06/02/2023 2:18 PM
7424 - If needed, use a sharp utility knife to cut sealant around edges of sensor. A...
Remark
Published
06/02/2023 2:21 PM
7459 - 7425 - Disconnect wire connector; Remark:7426
Procedure Step
Published
06/02/2023 5:29 PM
7425 - Disconnect wire connector
Instruction
Published
06/02/2023 2:48 PM
7426 - The wire connector is located on the right side of existing sensor.
Remark
Published
06/02/2023 2:53 PM
7460 - 7427 - Loosen two (2) mounting screws; Remark:7428
Procedure Step
Published
06/02/2023 5:30 PM
7429 - Note : Some existing occupancy sensors are installed using screws and nuts, ...
Annotation
Published
06/02/2023 3:09 PM
7427 - Loosen two (2) mounting screws
Instruction
Published
06/02/2023 2:56 PM
7428 - Use a medium Phillips (PH2) screwdriver. If screws and nuts were used, an adj...
Remark
Published
06/02/2023 3:04 PM
7461 - 7430 - Remove faulty occupancy sensor; Remark:7431
Procedure Step
Published
06/02/2023 5:31 PM
7430 - Remove faulty occupancy sensor
Instruction
Published
06/02/2023 3:11 PM
7431 - If a Wizard G3 sensor is being removed, push up on both sides to free the sen...
Remark
Published
09/29/2023 1:49 PM
3397 - 3395 - Label faulty component; Remark:3396
Procedure Step
Published
07/21/2024 6:59 AM
3395 - Label faulty component
Instruction
Published
08/07/2021 11:07 AM
3396 - Use tag or tape. Include date of removal, description of failure symptoms, co...
Remark
Published
08/09/2021 11:35 AM
7481 - 7432 - Install new occupancy sensor; Remark:
Procedure Step
Published
06/02/2023 9:46 PM
7432 - Install new occupancy sensor
Instruction
Published
06/02/2023 3:27 PM
7463 - 7433 - Mount new sensor; Remark:7434
Procedure Step
Published
06/02/2023 5:32 PM
7433 - Mount new sensor
Instruction
Published
06/02/2023 3:29 PM
7434 - First, slide left side onto mounting screw.
Remark
Published
04/13/2025 5:44 PM
9206 - Then, place right side over mounting screw and push down.
Remark
Published
09/29/2023 1:55 PM
7464 - 7435 - Tighten two (2) mounting screws; Remark:7436
Procedure Step
Published
06/02/2023 5:33 PM
7435 - Tighten two (2) mounting screws
Instruction
Published
06/02/2023 3:40 PM
7436 - Use medium Phillips (PH2) screwdriver. Take care not to overtighten.
Remark
Published
04/13/2025 5:45 PM
7482 - 7437 - Route wiring through clamp and connect; Remark:7488
Procedure Step
Published
06/02/2023 10:42 PM
7437 - Route wiring through clamp and connect
Instruction
Published
06/02/2023 3:53 PM
7488 - Clamp and Connect
Remark
Published
06/02/2023 10:49 PM
7465 - 7439 - Adjust angle of the radar antenna; Remark:7438
Procedure Step
Published
04/13/2025 6:19 PM
7439 - Adjust angle of the radar antenna
Instruction
Published
04/13/2025 5:45 PM
7438 - The angle is adjusted by manually rotating the antenna up or down. The defaul...
Remark
Published
09/29/2023 1:58 PM
7279 - 7249 - Return equipment to normal operating condition; Remark:
Procedure Step
Published
04/27/2023 4:13 PM
7249 - Return equipment to normal operating condition
Instruction
Published
04/08/2025 3:22 PM
7466 - 7440 - Hold door open; Remark:7441
Procedure Step
Published
06/02/2023 5:35 PM
7440 - Hold door open
Instruction
Published
06/02/2023 4:10 PM
7441 - Do not move door. Door must remain stationary to prevent occupancy.
Remark
Published
04/13/2025 5:45 PM
7280 - 7250 - Power on RPM; Remark:7251
Procedure Step
Published
04/27/2023 4:14 PM
7250 - Power on RPM
Instruction
Published
05/01/2023 8:31 AM
7251 - Move LD-260 switch to ON position. The LED PWR ON
Remark
Published
05/10/2023 3:14 PM
7468 - 7304 - Confirm RPM has restarted correctly; Remark:7487
Procedure Step
Published
06/02/2023 5:36 PM
7304 - Confirm RPM has restarted correctly
Instruction
Published
05/01/2023 8:31 AM
7487 - The SC-770 controller will display "OK" following Power On Self-Test (POST) a...
Remark
Published
06/02/2023 10:35 PM
7282 - 7254 - Confirm network connection; Remark:7255
Procedure Step
Published
04/27/2023 4:15 PM
7254 - Confirm network connection
Instruction
Published
04/27/2023 2:22 PM
7255 - Contact operators to confirm communications have been reestablished between RPM ...
Remark
Published
05/10/2023 3:15 PM
7470 - 7442 - Generate occupancy; Remark:7443
Procedure Step
Published
06/02/2023 5:37 PM
7442 - Generate occupancy
Instruction
Published
06/02/2023 4:19 PM
7443 - Create motion in front of occupancy sensor. While holding the door open and s...
Remark
Published
06/02/2023 4:21 PM
7471 - 7444 - Verify occupancy sensor functionality; Remark:7445
Procedure Step
Published
06/02/2023 5:38 PM
7444 - Verify occupancy sensor functionality
Instruction
Published
06/02/2023 4:32 PM
7445 - IXIO-DT1 green sensor light will illuminate.
Remark
Published
06/02/2023 4:35 PM
8973 - Left latch on the LCD screen will indicate a “closed” circuit.
Remark
Published
09/25/2023 11:05 PM
8974 - SC-770 status will read “OCCUPIED”.
Remark
Published
09/25/2023 11:06 PM
7472 - 7446 - Install sensor cover; Remark:7447
Procedure Step
Published
06/02/2023 5:38 PM
7446 - Install sensor cover
Instruction
Published
06/02/2023 4:37 PM
7447 - The cover should snap into place.
Remark
Published
06/02/2023 4:38 PM
7473 - 7448 - If needed, apply sealant; Remark:7449
Procedure Step
Published
06/02/2023 5:39 PM
7448 - If needed, apply sealant
Instruction
Published
06/02/2023 4:39 PM
7449 - If used outdoors, sealant should be applied to top and sides of cover. Do not...
Remark
Published
06/02/2023 4:41 PM
7474 - 7310 - Enable tamper switches; Remark:7451
Procedure Step
Published
06/02/2023 5:41 PM
7310 - Enable tamper switches
Instruction
Published
05/01/2023 8:36 AM
7451 - Remove magnets and/or adhesive tape from door tamper switches.
Remark
Published
04/13/2025 5:46 PM
7283 - 7256 - Close and lock all RPM doors; Remark:
Procedure Step
Published
09/01/2023 11:45 PM
7256 - Close and lock all RPM doors
Instruction
Published
04/27/2023 2:21 PM
7842 - 7820 - Inform system operators upon completion of maintenance action; Remark:
Procedure Step
Published
07/07/2023 11:15 PM
7820 - Inform system operators upon completion of maintenance action
Instruction
Published
07/07/2023 10:02 PM
322 - 321 - Document maintenance actions; Remark:
Procedure Step
Published
06/17/2021 9:49 AM
321 - Document maintenance actions
Instruction
Published
04/21/2025 11:19 AM
2869 - 2585 - Document maintenance performed; Remark:2866
Procedure Step
Published
06/18/2021 5:58 PM
2585 - Document maintenance performed
Instruction
Published
07/09/2021 12:15 PM
2866 - Record observations, times, and results for the maintenance report.
Remark
Published
04/21/2025 11:39 AM
4706 - 4705 - Submit report; Remark:4864
Procedure Step
Published
06/29/2022 9:50 AM
4705 - Submit report
Instruction
Published
06/29/2022 9:50 AM
4864 - As specified by management or contractual obligations.
Remark
Published
07/28/2022 1:36 PM
Corrective Maintenance Procedure
Document Type
Published
03/02/2020 3:32 PM
Instrument is not functioning correctly
Frequency
Published
12/19/2022 5:52 PM
Note
Annotation Type
Published
03/02/2020 3:25 PM
Technician 1
Skill Level
Published
05/14/2020 2:56 PM
Keys to access RPM
Replacement Parts
Published
04/27/2023 6:56 PM
Magnets and adhesive tape to disable door tamper switches
Replacement Parts
Published
06/02/2023 10:08 PM
Medium slotted screwdriver
Replacement Parts
Published
06/02/2023 10:08 PM
Medium Phillips (PH2) screwdriver
Tools
Published
04/24/2020 4:40 PM
Adjustable wrench
Replacement Parts
Published
06/02/2023 10:08 PM
Utility knife
Tools
Published
05/19/2020 1:54 PM
Orange/yellow safety vest
Replacement Parts
Published
04/27/2023 6:56 PM
Safety shoes
Replacement Parts
Published
04/27/2023 6:56 PM
Gloves
Replacement Parts
Published
05/10/2023 3:28 PM
Protective headwear: glasses, hard hat
Replacement Parts
Published
05/10/2023 3:31 PM
Orange traffic cones
Replacement Parts
Published
04/27/2023 6:56 PM
Disable tamper switch
படம்
Published
09/07/2023 8:22 PM
Disable Tamper Switch
படம்
Published
06/02/2023 2:28 PM
LD-260 Disconnect Switch Power Off
படம்
Published
04/24/2023 12:49 PM
Remove Occupancy Sensor Cover
படம்
Published
06/02/2023 2:38 PM
The IXIO-DT1 should come with the narrow field antenna installed
படம்
Published
09/25/2023 8:35 PM
Verify narrow field radar antenna is installed
படம்
Published
09/25/2023 8:38 PM
Verify narrow field radar antenna is installed 2
படம்
Published
09/25/2023 8:39 PM
Uninstall Occupancy Sensor Cover
படம்
Published
06/02/2023 2:37 PM
Disconnect Wire Connector
படம்
Published
06/02/2023 2:53 PM
Loosen Two Mounting screws
படம்
Published
06/02/2023 3:04 PM
Remove faulty Occupancy Sensor
படம்
Published
09/29/2023 1:47 PM
Push Occupancy Sensor to the right
படம்
Published
09/29/2023 1:48 PM
Mount new sensor
படம்
Published
09/25/2023 8:52 PM
Push Down Over Mounting Screw to Install Occupancy Sensor
படம்
Published
06/02/2023 3:51 PM
Tighten Occupancy Sensor Mounting Screws
படம்
Published
06/02/2023 3:48 PM
Route wiring through clamp and connect
படம்
Published
06/02/2023 3:55 PM
Adjust angle of the radar antenna
படம்
Published
09/25/2023 8:56 PM
Adjust angle of the radar antenna2
படம்
Published
09/25/2023 8:58 PM
LD-260 Disconnect Switch Power On
படம்
Published
05/04/2023 3:37 PM
IXIO-DT1 green sensor light will illuminate
படம்
Published
09/25/2023 9:37 PM
Verify occupancy sensor functionality
படம்
Published
09/25/2023 9:38 PM
Verify occupancy sensor functionality2
படம்
Published
09/25/2023 9:39 PM
Install Occupancy Sensor Cover
படம்
Published
06/02/2023 4:26 PM
Occupancy Sensor Sealant Application
படம்
Published
06/02/2023 4:30 PM
Remove Magnet from Tamper.PNG
படம்
Published
09/28/2023 9:37 AM
Remove Magnet on Tamper Switch
படம்
Published
06/02/2023 4:31 PM