Rapiscan VM-250 Vehicle Monitor |
Device
|
Published
|
10/14/2024 9:50 AM
|
Rapiscan TM-850 Rail Monitor |
Device
|
Published
|
09/18/2024 10:28 AM
|
8468 - 1401 - Establish Initial Conditions; Remark: |
Procedure Step
|
Published
|
09/16/2023 4:47 PM
|
1401 - Establish Initial Conditions |
Instruction
|
Published
|
09/30/2022 3:14 PM
|
7268 - 7231 - Close lane; Remark:7233 |
Procedure Step
|
Published
|
04/27/2023 7:01 PM
|
9053 - Warning : Traffic should temporarily be rerouted or halted during conduction of this pr... |
Annotation
|
Published
|
09/27/2023 9:09 AM
|
7231 - Close lane |
Instruction
|
Published
|
04/18/2023 1:00 PM
|
7233 - Use orange safety (traffic control) cones to setup barriers. Practice establi... |
Remark
|
Published
|
04/24/2023 12:18 PM
|
7269 - 7232 - Open RPM door; Remark:7234 |
Procedure Step
|
Published
|
04/27/2023 7:02 PM
|
7232 - Open RPM door |
Instruction
|
Published
|
04/18/2023 1:02 PM
|
7234 - Open all doors needed to access components. |
Remark
|
Published
|
04/19/2025 7:48 PM
|
7270 - 7235 - Power off RPM; Remark:7236 |
Procedure Step
|
Published
|
09/01/2023 7:57 PM
|
7235 - Power off RPM |
Instruction
|
Published
|
04/24/2023 12:30 PM
|
7236 - Move LD-260 switch to OFF position. The PWR ON |
Remark
|
Published
|
04/27/2023 4:25 PM
|
8623 - 8613 - Uninstall Faulty Sensor; Remark: |
Procedure Step
|
Published
|
09/19/2023 12:06 PM
|
8613 - Uninstall Faulty Sensor |
Instruction
|
Published
|
09/19/2023 11:40 AM
|
8624 - 8614 - Locate infrared sensors; Remark:8615 |
Procedure Step
|
Published
|
09/19/2023 5:39 PM
|
8614 - Locate infrared sensors |
Instruction
|
Published
|
09/19/2023 11:41 AM
|
8615 - Typical sensor locations are as follows: Control pillar hou... |
Remark
|
Published
|
09/19/2023 11:43 AM
|
8625 - 8617 - Disconnect applicable infrared sensors; Remark:8618 |
Procedure Step
|
Published
|
09/19/2023 12:08 PM
|
8617 - Disconnect applicable infrared sensors |
Instruction
|
Published
|
09/19/2023 11:49 AM
|
8618 - To disconnect sensor cable, turn collar counterclockwise and pull away from s... |
Remark
|
Published
|
09/19/2023 11:51 AM
|
8626 - 8619 - Unscrew mounting nut; Remark:8620 |
Procedure Step
|
Published
|
09/19/2023 12:09 PM
|
8619 - Unscrew mounting nut |
Instruction
|
Published
|
09/19/2023 11:59 AM
|
8620 - Rotate threaded nut counterclockwise. It may be necessary to hold the infrare... |
Remark
|
Published
|
09/19/2023 11:58 AM
|
8627 - 8621 - Remove sensor from back of door; Remark:8622 |
Procedure Step
|
Published
|
09/19/2023 12:09 PM
|
8621 - Remove sensor from back of door |
Instruction
|
Published
|
09/19/2023 12:01 PM
|
8622 - Removal of infrared sensor |
Remark
|
Published
|
09/19/2023 12:03 PM
|
8660 - 8658 - Retain sensor O-ring; Remark:8659 |
Procedure Step
|
Published
|
09/19/2023 5:56 PM
|
8658 - Retain sensor O-ring |
Instruction
|
Published
|
09/19/2023 5:55 PM
|
8659 - Retain Sensor O-ring |
Remark
|
Published
|
09/19/2023 5:55 PM
|
3397 - 3395 - Label faulty component; Remark:3396 |
Procedure Step
|
Published
|
07/21/2024 6:59 AM
|
3395 - Label faulty component |
Instruction
|
Published
|
08/07/2021 11:07 AM
|
3396 - Use tag or tape. Include date of removal, description of failure symptoms, co... |
Remark
|
Published
|
08/09/2021 11:35 AM
|
8641 - 8628 - Install New Sensor; Remark: |
Procedure Step
|
Published
|
09/19/2023 4:09 PM
|
8628 - Install New Sensor |
Instruction
|
Published
|
09/19/2023 12:35 PM
|
8642 - 8629 - Verify replacement sensor matches function and color of sensor previously rem...; Remark:8630 |
Procedure Step
|
Published
|
09/19/2023 4:10 PM
|
8629 - Verify replacement sensor matches function and color of sensor previously rem... |
Instruction
|
Published
|
09/19/2023 12:36 PM
|
8630 - Infrared sensor identification |
Remark
|
Published
|
09/19/2023 12:48 PM
|
8643 - 8631 - Remove nut closest to sensor face; Remark:8632 |
Procedure Step
|
Published
|
09/19/2023 4:11 PM
|
8631 - Remove nut closest to sensor face |
Instruction
|
Published
|
09/19/2023 12:48 PM
|
8632 - Infrared Nut |
Remark
|
Published
|
09/19/2023 12:50 PM
|
8644 - 8633 - Add retained O-ring; Remark:8634 |
Procedure Step
|
Published
|
09/19/2023 4:12 PM
|
8633 - Add retained O-ring |
Instruction
|
Published
|
09/19/2023 3:52 PM
|
8634 - Infrared Sensor O-ring |
Remark
|
Published
|
09/19/2023 3:55 PM
|
8645 - 8635 - Mount new infrared sensor; Remark:8636 |
Procedure Step
|
Published
|
09/19/2023 4:13 PM
|
8635 - Mount new infrared sensor |
Instruction
|
Published
|
09/19/2023 3:57 PM
|
8636 - Insert sensor through hole on the back side of door. |
Remark
|
Published
|
09/19/2023 4:01 PM
|
8646 - 8638 - Add outside nut to front and hand tighten; Remark:8639 |
Procedure Step
|
Published
|
09/19/2023 4:14 PM
|
8637 - Note : The nut on the outside should be flush with the sensor. |
Annotation
|
Published
|
09/19/2023 4:01 PM
|
8638 - Add outside nut to front and hand tighten |
Instruction
|
Published
|
09/19/2023 4:02 PM
|
8639 - Use the adjustable wrench to snug the nut up slightly, just enough for the ga... |
Remark
|
Published
|
09/19/2023 4:05 PM
|
8647 - 8661 - Reconnect applicable cable previously removed in Step 4-6; Remark:8559 |
Procedure Step
|
Published
|
09/19/2023 4:15 PM
|
5553 - Caution : Correct placement of connectors and wiring is critical to proper operation. |
Annotation
|
Published
|
10/28/2022 2:19 PM
|
8661 - Reconnect applicable cable previously removed in Step 4-4 |
Instruction
|
Published
|
09/19/2023 6:14 PM
|
8559 - To reconnect sensor cable, align connectors, push towards sensor, and turn co... |
Remark
|
Published
|
09/29/2023 12:05 PM
|
7279 - 7249 - Return equipment to normal operating condition; Remark: |
Procedure Step
|
Published
|
04/27/2023 4:13 PM
|
7249 - Return equipment to normal operating condition |
Instruction
|
Published
|
04/08/2025 3:22 PM
|
8503 - 7250 - Power on RPM; Remark:7251 |
Procedure Step
|
Published
|
09/16/2023 9:00 PM
|
7250 - Power on RPM |
Instruction
|
Published
|
05/01/2023 8:31 AM
|
7251 - Move LD-260 switch to ON position. The LED PWR ON |
Remark
|
Published
|
05/10/2023 3:14 PM
|
7281 - 7252 - Verify RPM start-up; Remark:7253 |
Procedure Step
|
Published
|
04/20/2025 3:26 PM
|
7252 - Verify RPM start-up |
Instruction
|
Published
|
04/27/2023 2:23 PM
|
7253 - RPM will perform a power on self-test (POST) and collect a background radiati... |
Remark
|
Published
|
05/10/2023 3:14 PM
|
8654 - 8648 - Verify SC-770 display shows OCCUPIED when infrared beams are...; Remark:8651 |
Procedure Step
|
Published
|
09/19/2023 4:52 PM
|
8648 - Verify SC-770 display shows OCCUPIED when infrared beams are... |
Instruction
|
Published
|
09/19/2023 4:23 PM
|
8651 - SC-770 Occupied |
Remark
|
Published
|
09/19/2023 4:30 PM
|
8655 - 8649 - Test sensors independently; Remark:8650 |
Procedure Step
|
Published
|
09/19/2023 4:53 PM
|
8649 - Test sensors independently |
Instruction
|
Published
|
09/19/2023 4:24 PM
|
8650 - Disconnect one receiver cable, shut door, and clear sensors for five (5) seco... |
Remark
|
Published
|
09/19/2023 4:28 PM
|
8656 - 8648 - Verify SC-770 display shows OCCUPIED when infrared beams are...; Remark:8651 |
Procedure Step
|
Published
|
09/19/2023 4:54 PM
|
8653 - 8652 - Repeat steps 4-4 through 4-6 for other receiver sensors.; Remark: |
Procedure Step
|
Published
|
04/13/2025 6:16 PM
|
8652 - Repeat steps 4-4 through 4-6 for other receiver sensors. |
Instruction
|
Published
|
04/13/2025 6:11 PM
|
7282 - 7254 - Confirm network connection; Remark:7255 |
Procedure Step
|
Published
|
04/27/2023 4:15 PM
|
7254 - Confirm network connection |
Instruction
|
Published
|
04/27/2023 2:22 PM
|
7255 - Contact operators to confirm communications have been reestablished between RPM ... |
Remark
|
Published
|
05/10/2023 3:15 PM
|
7283 - 7256 - Close and lock all RPM doors; Remark: |
Procedure Step
|
Published
|
09/01/2023 11:45 PM
|
7256 - Close and lock all RPM doors |
Instruction
|
Published
|
04/27/2023 2:21 PM
|
7842 - 7820 - Inform system operators upon completion of maintenance action; Remark: |
Procedure Step
|
Published
|
07/07/2023 11:15 PM
|
7820 - Inform system operators upon completion of maintenance action |
Instruction
|
Published
|
07/07/2023 10:02 PM
|
322 - 321 - Document maintenance actions; Remark: |
Procedure Step
|
Published
|
06/17/2021 9:49 AM
|
321 - Document maintenance actions |
Instruction
|
Published
|
04/21/2025 11:19 AM
|
2869 - 2585 - Document maintenance performed; Remark:2866 |
Procedure Step
|
Published
|
06/18/2021 5:58 PM
|
2585 - Document maintenance performed |
Instruction
|
Published
|
07/09/2021 12:15 PM
|
2866 - Record observations, times, and results for the maintenance report. |
Remark
|
Published
|
04/21/2025 11:39 AM
|
4706 - 4705 - Submit report; Remark:4864 |
Procedure Step
|
Published
|
06/29/2022 9:50 AM
|
4705 - Submit report |
Instruction
|
Published
|
06/29/2022 9:50 AM
|
4864 - As specified by management or contractual obligations. |
Remark
|
Published
|
07/28/2022 1:36 PM
|
Corrective Maintenance Procedure |
Document Type
|
Published
|
03/02/2020 3:32 PM
|
30 minutes |
Duration
|
Published
|
04/01/2020 11:35 AM
|
If system is locked in continuous occupancy or speed indication does not function |
Frequency
|
Published
|
09/19/2023 5:28 PM
|
Warning |
Annotation Type
|
Published
|
03/02/2020 3:25 PM
|
Note |
Annotation Type
|
Published
|
03/02/2020 3:25 PM
|
Caution |
Annotation Type
|
Published
|
03/02/2020 3:24 PM
|
Technician 1 |
Skill Level
|
Published
|
05/14/2020 2:56 PM
|
Keys to access RPM |
Replacement Parts
|
Published
|
04/27/2023 6:56 PM
|
Adjustable wrench |
Replacement Parts
|
Published
|
06/02/2023 10:08 PM
|
Ladder: 2 meters, 6 feet tall; non-conducting |
Replacement Parts
|
Published
|
09/01/2023 9:34 PM
|
Reflective safety vest if required |
Replacement Parts
|
Published
|
06/20/2023 4:47 PM
|
LD-260 Disconnect Switch Power Off |
படம்
|
Published
|
04/24/2023 12:49 PM
|
Remove Infrared Sensor Nut |
படம்
|
Published
|
09/19/2023 11:57 AM
|
Mount Infrared Sensors |
படம்
|
Published
|
09/19/2023 5:51 PM
|
Retained Infrared O-ring |
படம்
|
Published
|
09/19/2023 5:44 PM
|
Infrared Sensor Identification |
படம்
|
Published
|
09/19/2023 12:39 PM
|
Outside Nut of Infrared Sensor |
படம்
|
Published
|
09/19/2023 12:49 PM
|
Tighten Infrared Sensor Nut |
படம்
|
Published
|
09/19/2023 4:03 PM
|
Infrared Connection |
படம்
|
Published
|
09/29/2023 12:02 PM
|
Infrared Cable Installation |
படம்
|
Published
|
09/17/2023 10:12 PM
|
Infrared Sensor Cable |
படம்
|
Published
|
09/17/2023 10:13 PM
|
LD-260 Disconnect Switch Power On |
படம்
|
Published
|
05/04/2023 3:37 PM
|
SC-770 Occupied |
படம்
|
Published
|
09/19/2023 4:30 PM
|