Rapiscan PM-700 Pedestrian Monitor |
Device
|
Not translated
|
06/20/2024 11:38 AM
|
Rapiscan VM-250 Vehicle Monitor |
Device
|
Not translated
|
10/14/2024 9:50 AM
|
Rapiscan TM-850 Rail Monitor |
Device
|
Not translated
|
09/18/2024 10:28 AM
|
Rapiscan CM-267 Conveyor Monitor |
Device
|
Not translated
|
06/27/2024 1:02 PM
|
7927 - Définissez un état initial |
Instruction
|
Published
|
07/12/2023 12:23 AM
|
1402 - 7927 - Définissez un état initial; Remark: |
Procedure Step
|
Published
|
09/30/2022 1:47 PM
|
9053 - Warning : Traffic should temporarily be rerouted or halted during conduction of this pr... |
Annotation
|
Not translated
|
09/27/2023 9:09 AM
|
7231 - Close lane |
Instruction
|
Not translated
|
04/18/2023 1:00 PM
|
7233 - Use orange safety (traffic control) cones to setup barriers. Practice establi... |
Remark
|
Not translated
|
04/24/2023 12:18 PM
|
7268 - 7231 - Close lane; Remark:7233 |
Procedure Step
|
Not translated
|
04/27/2023 7:01 PM
|
7232 - Open RPM door |
Instruction
|
Not translated
|
04/18/2023 1:02 PM
|
7234 - Open all doors needed to access components. |
Remark
|
Not translated
|
04/19/2025 7:48 PM
|
7269 - 7232 - Open RPM door; Remark:7234 |
Procedure Step
|
Not translated
|
04/27/2023 7:02 PM
|
7235 - Power off RPM |
Instruction
|
Not translated
|
04/24/2023 12:30 PM
|
7236 - Move LD-260 switch to OFF position. The PWR ON |
Remark
|
Not translated
|
04/27/2023 4:25 PM
|
7270 - 7235 - Power off RPM; Remark:7236 |
Procedure Step
|
Not translated
|
09/01/2023 7:57 PM
|
8066 - Débranchez le connecteur supérieur gauche |
Instruction
|
Published
|
07/31/2023 1:49 PM
|
8065 - Le connecteur d’entrée d’alimentation est un connecteur Molex à trois broches. L... |
Remark
|
Published
|
07/31/2023 1:54 PM
|
8070 - 8066 - Débranchez le connecteur supérieur gauche; Remark:8065 |
Procedure Step
|
Published
|
07/31/2023 1:54 PM
|
8076 - Remplacez le fusible |
Instruction
|
Published
|
07/31/2023 4:31 PM
|
8077 - 8076 - Remplacez le fusible; Remark: |
Procedure Step
|
Published
|
07/31/2023 4:31 PM
|
8074 - Retirez l’écrou de retenue du commutateur |
Instruction
|
Published
|
07/31/2023 4:32 PM
|
8073 - Une petite clé polygonale ou clé à molette peut être nécessaire pour desserrer l... |
Remark
|
Published
|
07/31/2023 4:38 PM
|
8075 - 8074 - Retirez l’écrou de retenue du commutateur; Remark:8073 |
Procedure Step
|
Published
|
07/31/2023 4:38 PM
|
8083 - Retirez les quatre vis de la plaque du capot |
Instruction
|
Published
|
07/31/2023 7:44 PM
|
8082 - |
Remark
|
Not translated
|
07/31/2023 7:46 PM
|
8084 - 8083 - Retirez les quatre vis de la plaque du capot; Remark:8082 |
Procedure Step
|
Published
|
07/31/2023 7:46 PM
|
8081 - Retirez la plaque du capot |
Instruction
|
Published
|
07/31/2023 7:51 PM
|
8080 - |
Remark
|
Not translated
|
07/31/2023 7:52 PM
|
8085 - 8081 - Retirez la plaque du capot; Remark:8080 |
Procedure Step
|
Published
|
07/31/2023 7:52 PM
|
8079 - Retirez le fusible défectueux |
Instruction
|
Published
|
07/31/2023 7:53 PM
|
8078 - Dégagez ou retirez délicatement le fusible défectueux de son porte-fusible. |
Remark
|
Published
|
07/31/2023 7:54 PM
|
8086 - 8079 - Retirez le fusible défectueux; Remark:8078 |
Procedure Step
|
Published
|
07/31/2023 7:54 PM
|
3395 - Étiquetez le composant défectueux |
Instruction
|
Published
|
08/07/2021 11:07 AM
|
3396 - Utilisez une étiquette ou du ruban adhésif. Incluez la date du retrait, la descr... |
Remark
|
Published
|
08/09/2021 11:35 AM
|
3397 - 3395 - Étiquetez le composant défectueux; Remark:3396 |
Procedure Step
|
Published
|
07/21/2024 6:59 AM
|
8096 - Installez un nouveau fusible |
Instruction
|
Published
|
07/31/2023 7:55 PM
|
8097 - 8096 - Installez un nouveau fusible; Remark: |
Procedure Step
|
Published
|
07/31/2023 7:56 PM
|
10322 - Place the new fuse in the fuse holder. |
Instruction
|
Not translated
|
11/17/2023 7:18 PM
|
10323 - 10322 - Place the new fuse in the fuse holder.; Remark: |
Procedure Step
|
Not translated
|
11/17/2023 7:19 PM
|
8094 - Installez la plaque du capot |
Instruction
|
Published
|
07/31/2023 7:56 PM
|
8098 - 8094 - Installez la plaque du capot; Remark: |
Procedure Step
|
Published
|
07/31/2023 7:56 PM
|
8093 - Installez les quatre (4) vis |
Instruction
|
Published
|
07/31/2023 7:57 PM
|
8099 - 8093 - Installez les quatre (4) vis; Remark: |
Procedure Step
|
Published
|
07/31/2023 7:57 PM
|
8092 - Installez l’écrou de retenue du commutateur |
Instruction
|
Published
|
07/31/2023 7:57 PM
|
8100 - 8092 - Installez l’écrou de retenue du commutateur; Remark: |
Procedure Step
|
Published
|
07/31/2023 7:58 PM
|
7249 - Return equipment to normal operating condition |
Instruction
|
Not translated
|
04/08/2025 3:22 PM
|
7279 - 7249 - Return equipment to normal operating condition; Remark: |
Procedure Step
|
Not translated
|
04/27/2023 4:13 PM
|
8088 - Rebranchez le connecteur supérieur gauche |
Instruction
|
Published
|
07/31/2023 8:01 PM
|
8087 - Lorsque le connecteur est reconnecté, le voyant orange doit être allumé. |
Remark
|
Published
|
07/31/2023 8:05 PM
|
8089 - 8088 - Rebranchez le connecteur supérieur gauche; Remark:8087 |
Procedure Step
|
Published
|
07/31/2023 8:06 PM
|
7250 - Power on RPM |
Instruction
|
Not translated
|
05/01/2023 8:31 AM
|
7251 - Move LD-260 switch to ON position. The LED PWR ON |
Remark
|
Not translated
|
05/10/2023 3:14 PM
|
7280 - 7250 - Power on RPM; Remark:7251 |
Procedure Step
|
Not translated
|
04/27/2023 4:14 PM
|
7252 - Verify RPM start-up |
Instruction
|
Not translated
|
04/27/2023 2:23 PM
|
7253 - RPM will perform a power on self-test (POST) and collect a background radiati... |
Remark
|
Not translated
|
05/10/2023 3:14 PM
|
7281 - 7252 - Verify RPM start-up; Remark:7253 |
Procedure Step
|
Not translated
|
04/20/2025 3:26 PM
|
7254 - Confirm network connection |
Instruction
|
Not translated
|
04/27/2023 2:22 PM
|
7255 - Contact operators to confirm communications have been reestablished between RPM ... |
Remark
|
Not translated
|
05/10/2023 3:15 PM
|
7282 - 7254 - Confirm network connection; Remark:7255 |
Procedure Step
|
Not translated
|
04/27/2023 4:15 PM
|
7256 - Close and lock all RPM doors |
Instruction
|
Not translated
|
04/27/2023 2:21 PM
|
7283 - 7256 - Close and lock all RPM doors; Remark: |
Procedure Step
|
Not translated
|
09/01/2023 11:45 PM
|
7820 - Inform system operators upon completion of maintenance action |
Instruction
|
Not translated
|
07/07/2023 10:02 PM
|
7842 - 7820 - Inform system operators upon completion of maintenance action; Remark: |
Procedure Step
|
Not translated
|
07/07/2023 11:15 PM
|
321 - Consignez les actions de maintenance |
Instruction
|
Published
|
04/21/2025 11:19 AM
|
322 - 321 - Consignez les actions de maintenance; Remark: |
Procedure Step
|
Published
|
06/17/2021 9:49 AM
|
2585 - Consignez la maintenance effectuée |
Instruction
|
Published
|
07/09/2021 12:15 PM
|
2866 - Enregistrez les observations, les horodatages et les résultats dans le rapport d... |
Remark
|
Published
|
04/21/2025 11:39 AM
|
2869 - 2585 - Consignez la maintenance effectuée; Remark:2866 |
Procedure Step
|
Published
|
06/18/2021 5:58 PM
|
4705 - Soumettez le rapport |
Instruction
|
Published
|
06/29/2022 9:50 AM
|
4864 - Comme spécifié par l’encadrement ou les obligations contractuelles. |
Remark
|
Published
|
07/28/2022 1:36 PM
|
4706 - 4705 - Soumettez le rapport; Remark:4864 |
Procedure Step
|
Published
|
06/29/2022 9:50 AM
|
Procédure de maintenance corrective |
Document Type
|
Published
|
03/02/2020 3:32 PM
|
20 minutes |
Duration
|
Published
|
05/18/2020 5:44 PM
|
Upon failure of the fuse |
Frequency
|
Not translated
|
11/17/2023 6:27 PM
|
Avertissement |
Annotation Type
|
Published
|
03/02/2020 3:25 PM
|
Technicien 2 |
Skill Level
|
Published
|
04/09/2020 1:17 AM
|
Clés d’accès au RPM |
Replacement Parts
|
Published
|
04/27/2023 6:56 PM
|
Petit tournevis Phillips (PH1) |
Tools
|
Published
|
05/14/2020 2:48 PM
|
Tournevis Phillips moyen (PH2) |
Tools
|
Published
|
04/24/2020 4:40 PM
|
Gilet de sécurité orange/jaune |
Replacement Parts
|
Published
|
04/27/2023 6:56 PM
|
Chaussures de sécurité |
Replacement Parts
|
Published
|
04/27/2023 6:56 PM
|
lunettes de sécurité |
Replacement Parts
|
Published
|
07/02/2023 4:48 PM
|
Échelle ; 2 mètres (6 pieds) de hauteur ; non-conductrice si nécessaire |
Replacement Parts
|
Published
|
07/02/2023 4:48 PM
|
Cônes de signalisation orange |
Replacement Parts
|
Published
|
04/27/2023 6:56 PM
|
petite clé à molette |
Tools
|
Published
|
07/31/2023 10:46 AM
|
LD-260 Disconnect Switch Power Off |
Image
|
Published
|
04/24/2023 12:49 PM
|
Unplugged LD-260 |
Image
|
Published
|
11/17/2023 6:50 PM
|
LD-260 Switch Power Off |
Image
|
Published
|
11/17/2023 6:49 PM
|
LD-260 Nut |
Image
|
Published
|
11/17/2023 7:06 PM
|
Remove four cover plate screws |
Image
|
Published
|
07/31/2023 7:46 PM
|
LD-260 Cover Removed |
Image
|
Published
|
11/17/2023 8:25 PM
|
LD-260 Fuse |
Image
|
Published
|
11/17/2023 7:10 PM
|
LD-260 |
Image
|
Published
|
07/31/2023 7:42 PM
|
LD-260 Disconnect Switch Power On |
Image
|
Published
|
05/04/2023 3:37 PM
|