Last Updated: 04/24/2025 1:44 AM

The following table lists all the components that make up the document.

Title Type Status Last Updated
Rapiscan PM-700 Pedestrian Monitor
Device
Not translated
06/20/2024 11:38 AM
Rapiscan VM-250 Vehicle Monitor
Device
Not translated
10/14/2024 9:50 AM
Rapiscan TM-850 Rail Monitor
Device
Not translated
09/18/2024 10:28 AM
Rapiscan CM-267 Conveyor Monitor
Device
Not translated
06/27/2024 1:02 PM
7927 - Définissez un état initial
Instruction
Published
07/12/2023 12:23 AM
1402 - 7927 - Définissez un état initial; Remark:
Procedure Step
Published
09/30/2022 1:47 PM
9053 - Warning : Traffic should temporarily be rerouted or halted during conduction of this pr...
Annotation
Not translated
09/27/2023 9:09 AM
7231 - Close lane
Instruction
Not translated
04/18/2023 1:00 PM
7233 - Use orange safety (traffic control) cones to setup barriers. Practice establi...
Remark
Not translated
04/24/2023 12:18 PM
7268 - 7231 - Close lane; Remark:7233
Procedure Step
Not translated
04/27/2023 7:01 PM
7232 - Open RPM door
Instruction
Not translated
04/18/2023 1:02 PM
7234 - Open all doors needed to access components.
Remark
Not translated
04/19/2025 7:48 PM
7269 - 7232 - Open RPM door; Remark:7234
Procedure Step
Not translated
04/27/2023 7:02 PM
7235 - Power off RPM
Instruction
Not translated
04/24/2023 12:30 PM
7236 - Move LD-260 switch to OFF position. The PWR ON
Remark
Not translated
04/27/2023 4:25 PM
7270 - 7235 - Power off RPM; Remark:7236
Procedure Step
Not translated
09/01/2023 7:57 PM
8066 - Débranchez le connecteur supérieur gauche
Instruction
Published
07/31/2023 1:49 PM
8065 - Le connecteur d’entrée d’alimentation est un connecteur Molex à trois broches. L...
Remark
Published
07/31/2023 1:54 PM
8070 - 8066 - Débranchez le connecteur supérieur gauche; Remark:8065
Procedure Step
Published
07/31/2023 1:54 PM
8076 - Remplacez le fusible
Instruction
Published
07/31/2023 4:31 PM
8077 - 8076 - Remplacez le fusible; Remark:
Procedure Step
Published
07/31/2023 4:31 PM
8074 - Retirez l’écrou de retenue du commutateur
Instruction
Published
07/31/2023 4:32 PM
8073 - Une petite clé polygonale ou clé à molette peut être nécessaire pour desserrer l...
Remark
Published
07/31/2023 4:38 PM
8075 - 8074 - Retirez l’écrou de retenue du commutateur; Remark:8073
Procedure Step
Published
07/31/2023 4:38 PM
8083 - Retirez les quatre vis de la plaque du capot
Instruction
Published
07/31/2023 7:44 PM
8082 -
Remark
Not translated
07/31/2023 7:46 PM
8084 - 8083 - Retirez les quatre vis de la plaque du capot; Remark:8082
Procedure Step
Published
07/31/2023 7:46 PM
8081 - Retirez la plaque du capot
Instruction
Published
07/31/2023 7:51 PM
8080 -
Remark
Not translated
07/31/2023 7:52 PM
8085 - 8081 - Retirez la plaque du capot; Remark:8080
Procedure Step
Published
07/31/2023 7:52 PM
8079 - Retirez le fusible défectueux
Instruction
Published
07/31/2023 7:53 PM
8078 - Dégagez ou retirez délicatement le fusible défectueux de son porte-fusible.
Remark
Published
07/31/2023 7:54 PM
8086 - 8079 - Retirez le fusible défectueux; Remark:8078
Procedure Step
Published
07/31/2023 7:54 PM
3395 - Étiquetez le composant défectueux
Instruction
Published
08/07/2021 11:07 AM
3396 - Utilisez une étiquette ou du ruban adhésif. Incluez la date du retrait, la descr...
Remark
Published
08/09/2021 11:35 AM
3397 - 3395 - Étiquetez le composant défectueux; Remark:3396
Procedure Step
Published
07/21/2024 6:59 AM
8096 - Installez un nouveau fusible
Instruction
Published
07/31/2023 7:55 PM
8097 - 8096 - Installez un nouveau fusible; Remark:
Procedure Step
Published
07/31/2023 7:56 PM
10322 - Place the new fuse in the fuse holder.
Instruction
Not translated
11/17/2023 7:18 PM
10323 - 10322 - Place the new fuse in the fuse holder.; Remark:
Procedure Step
Not translated
11/17/2023 7:19 PM
8094 - Installez la plaque du capot
Instruction
Published
07/31/2023 7:56 PM
8098 - 8094 - Installez la plaque du capot; Remark:
Procedure Step
Published
07/31/2023 7:56 PM
8093 - Installez les quatre (4) vis
Instruction
Published
07/31/2023 7:57 PM
8099 - 8093 - Installez les quatre (4) vis; Remark:
Procedure Step
Published
07/31/2023 7:57 PM
8092 - Installez l’écrou de retenue du commutateur
Instruction
Published
07/31/2023 7:57 PM
8100 - 8092 - Installez l’écrou de retenue du commutateur; Remark:
Procedure Step
Published
07/31/2023 7:58 PM
7249 - Return equipment to normal operating condition
Instruction
Not translated
04/08/2025 3:22 PM
7279 - 7249 - Return equipment to normal operating condition; Remark:
Procedure Step
Not translated
04/27/2023 4:13 PM
8088 - Rebranchez le connecteur supérieur gauche
Instruction
Published
07/31/2023 8:01 PM
8087 - Lorsque le connecteur est reconnecté, le voyant orange doit être allumé.
Remark
Published
07/31/2023 8:05 PM
8089 - 8088 - Rebranchez le connecteur supérieur gauche; Remark:8087
Procedure Step
Published
07/31/2023 8:06 PM
7250 - Power on RPM
Instruction
Not translated
05/01/2023 8:31 AM
7251 - Move LD-260 switch to ON position. The LED PWR ON
Remark
Not translated
05/10/2023 3:14 PM
7280 - 7250 - Power on RPM; Remark:7251
Procedure Step
Not translated
04/27/2023 4:14 PM
7252 - Verify RPM start-up
Instruction
Not translated
04/27/2023 2:23 PM
7253 - RPM will perform a power on self-test (POST) and collect a background radiati...
Remark
Not translated
05/10/2023 3:14 PM
7281 - 7252 - Verify RPM start-up; Remark:7253
Procedure Step
Not translated
04/20/2025 3:26 PM
7254 - Confirm network connection
Instruction
Not translated
04/27/2023 2:22 PM
7255 - Contact operators to confirm communications have been reestablished between RPM ...
Remark
Not translated
05/10/2023 3:15 PM
7282 - 7254 - Confirm network connection; Remark:7255
Procedure Step
Not translated
04/27/2023 4:15 PM
7256 - Close and lock all RPM doors
Instruction
Not translated
04/27/2023 2:21 PM
7283 - 7256 - Close and lock all RPM doors; Remark:
Procedure Step
Not translated
09/01/2023 11:45 PM
7820 - Inform system operators upon completion of maintenance action
Instruction
Not translated
07/07/2023 10:02 PM
7842 - 7820 - Inform system operators upon completion of maintenance action; Remark:
Procedure Step
Not translated
07/07/2023 11:15 PM
321 - Consignez les actions de maintenance
Instruction
Published
04/21/2025 11:19 AM
322 - 321 - Consignez les actions de maintenance; Remark:
Procedure Step
Published
06/17/2021 9:49 AM
2585 - Consignez la maintenance effectuée
Instruction
Published
07/09/2021 12:15 PM
2866 - Enregistrez les observations, les horodatages et les résultats dans le rapport d...
Remark
Published
04/21/2025 11:39 AM
2869 - 2585 - Consignez la maintenance effectuée; Remark:2866
Procedure Step
Published
06/18/2021 5:58 PM
4705 - Soumettez le rapport
Instruction
Published
06/29/2022 9:50 AM
4864 - Comme spécifié par l’encadrement ou les obligations contractuelles.
Remark
Published
07/28/2022 1:36 PM
4706 - 4705 - Soumettez le rapport; Remark:4864
Procedure Step
Published
06/29/2022 9:50 AM
Procédure de maintenance corrective
Document Type
Published
03/02/2020 3:32 PM
20 minutes
Duration
Published
05/18/2020 5:44 PM
Upon failure of the fuse
Frequency
Not translated
11/17/2023 6:27 PM
Avertissement
Annotation Type
Published
03/02/2020 3:25 PM
Technicien 2
Skill Level
Published
04/09/2020 1:17 AM
Clés d’accès au RPM
Replacement Parts
Published
04/27/2023 6:56 PM
Petit tournevis Phillips (PH1)
Tools
Published
05/14/2020 2:48 PM
Tournevis Phillips moyen (PH2)
Tools
Published
04/24/2020 4:40 PM
Gilet de sécurité orange/jaune
Replacement Parts
Published
04/27/2023 6:56 PM
Chaussures de sécurité
Replacement Parts
Published
04/27/2023 6:56 PM
lunettes de sécurité
Replacement Parts
Published
07/02/2023 4:48 PM
Échelle ; 2 mètres (6 pieds) de hauteur ; non-conductrice si nécessaire
Replacement Parts
Published
07/02/2023 4:48 PM
Cônes de signalisation orange
Replacement Parts
Published
04/27/2023 6:56 PM
petite clé à molette
Tools
Published
07/31/2023 10:46 AM
LD-260 Disconnect Switch Power Off
Image
Published
04/24/2023 12:49 PM
Unplugged LD-260
Image
Published
11/17/2023 6:50 PM
LD-260 Switch Power Off
Image
Published
11/17/2023 6:49 PM
LD-260 Nut
Image
Published
11/17/2023 7:06 PM
Remove four cover plate screws
Image
Published
07/31/2023 7:46 PM
LD-260 Cover Removed
Image
Published
11/17/2023 8:25 PM
LD-260 Fuse
Image
Published
11/17/2023 7:10 PM
LD-260
Image
Published
07/31/2023 7:42 PM
LD-260 Disconnect Switch Power On
Image
Published
05/04/2023 3:37 PM
DET-RPM-RAP-CM05

Remplacez le fusible dans le sectionneur de charge LD-260

Equipment Hierarchy
Rapiscan PM-700 Pedestrian Monitor
Rapiscan VM-250 Vehicle Monitor
Rapiscan TM-850 Rail Monitor
Rapiscan CM-267 Conveyor Monitor
Frequency
Upon failure of the fuse
Technician Level
Technician Level
Technicien 2
x 1
Duration
Time increment
20 minutes
Length of time
20
Tools Required
Clés d’accès au RPM
Petit tournevis Phillips (PH1)
Tournevis Phillips moyen (PH2)
Gilet de sécurité orange/jaune
Chaussures de sécurité
lunettes de sécurité
Échelle ; 2 mètres (6 pieds) de hauteur ; non-conductrice si nécessaire
Cônes de signalisation orange
petite clé à molette
Materials Required
Guide de maintenance du RPM Rév. 2.0
Fusible à action rapide 5 A 5x20 mm
Originators
David Alexander
Originating Organization
PNNL
Approver
Craig Stinson
Final Documentation
Rapport de maintenance corrective
Departmental Coordination

Coordonnez l’accès avec les opérateurs système

Date of Origin
Version
0.00
Version #
Revision Description

Noms des piliers mis à jour

Revision Date
Revision Author
Step 1

7268 - 7231 - Close lane; Remark:7233

Step 00

8070 - 8066 - Débranchez le connecteur supérieur gauche; Remark:8065

Step 00
Step 2
Instructions opérationnelles
Step 4
Step 5
Document Type
Corrective Maintenance Procedure
Percent Complete
60.92
Percent Complete W/Media
64.58