ID Title Content type Referenced in Step Referenced in Document Published
10470 10470 - Remark 3085 - 3077 - SELECT mode; Remark:10470 STEP: 3085 - 3077 - SELECT mode; Remark:10470
PRM-470 CG Survey Instrument
Rapiscan PRM-470 CGN Survey Instrument
10472 10472 - Remark 10347 - 313 - Power off instrument; Remark:10472 STEP: 10347 - 313 - Power off instrument; Remark:10472
Rapiscan PRM-470 CGN Survey Instrument
10473 10473 - Remark 10474 - 220 - Power on instrument; Remark:10473 STEP: 10474 - 220 - Power on instrument; Remark:10473
Rapiscan PRM-470 CGN Survey Instrument
10474 10474 - 220 - Power on instrument; Remark:10473 Procedure Step
10475 10475 - Remark
10477 10477 - Note : When using battery power there is no indication of battery level. When the ba... Annotation 10480 - 257 - Prepare instrument; Remark: STEP: 10480 - 257 - Prepare instrument; Remark:
Radiation Solutions Inc. RS-700 Operation
10478 10478 - Warning : When the system is plugged into an external power outlet, power runs to the b... Annotation 10480 - 257 - Prepare instrument; Remark: STEP: 10480 - 257 - Prepare instrument; Remark:
Radiation Solutions Inc. RS-700 Operation
10479 10479 - Caution : The detector is heavy (>60 lbs). Lift with caution, preferably with two pe... Annotation 10480 - 257 - Prepare instrument; Remark: STEP: 10480 - 257 - Prepare instrument; Remark:
Radiation Solutions Inc. RS-700 Operation
10480 10480 - 257 - Prepare instrument; Remark: Procedure Step
10482 10482 - Press and hold the Power button. Remark 10486 - 220 - Power on instrument; Remark:10482 STEP: 10486 - 220 - Power on instrument; Remark:10482
Viken Nighthawk-HBI Operation
10483 10483 - Remark 10485 - 10484 - Insert battery pack; Remark:10483 STEP: 10485 - 10484 - Insert battery pack; Remark:10483
Viken Nighthawk-HBI Operation
10484 10484 - Insert battery pack Instruction 5580 - 10484 - Insert battery pack; Remark:5578
10485 - 10484 - Insert battery pack; Remark:10483
STEP: 5580 - 10484 - Insert battery pack; Remark:5578
RadSeeker Check Connections
RadSeeker Stabilization Module Replacement

STEP: 10485 - 10484 - Insert battery pack; Remark:10483
Viken Nighthawk-HBI Operation
10485 10485 - 10484 - Insert battery pack; Remark:10483 Procedure Step
10486 10486 - 220 - Power on instrument; Remark:10482 Procedure Step
10487 10487 - Warning : Prior to use, the operator should read and understand the complete user’s g... Annotation 10489 - 257 - Prepare instrument; Remark: STEP: 10489 - 257 - Prepare instrument; Remark:
Viken Nighthawk-HBI Operation
10488 10488 - Caution : Do not block the air intake vents or outlet vents when the instrument is in u... Annotation 10489 - 257 - Prepare instrument; Remark: STEP: 10489 - 257 - Prepare instrument; Remark:
Viken Nighthawk-HBI Operation
10489 10489 - 257 - Prepare instrument; Remark: Procedure Step
10491 10491 - Remark 10500 - 10492 - Acknowledge warnings; Remark:10491 STEP: 10500 - 10492 - Acknowledge warnings; Remark:10491
Viken Nighthawk-HBI Operation
10492 10492 - Acknowledge warnings Instruction 10500 - 10492 - Acknowledge warnings; Remark:10491 STEP: 10500 - 10492 - Acknowledge warnings; Remark:10491
Viken Nighthawk-HBI Operation
10493 10493 - Type in your username and password. Remark 10499 - 10494 - Log into the application; Remark:10493 STEP: 10499 - 10494 - Log into the application; Remark:10493
Viken Nighthawk-HBI Operation
10494 10494 - Log in to application Instruction 10499 - 10494 - Log into the application; Remark:10493 STEP: 10499 - 10494 - Log into the application; Remark:10493
Viken Nighthawk-HBI Operation
10495 10495 - Note : See the user’s guide to set up the first administrator. Keep a secure recor... Annotation 10499 - 10494 - Log into the application; Remark:10493 STEP: 10499 - 10494 - Log into the application; Remark:10493
Viken Nighthawk-HBI Operation
10496 10496 - On the home screen, tap on the Viken icon. Remark 10498 - 10497 - Select HBI application; Remark:10496 STEP: 10498 - 10497 - Select HBI application; Remark:10496
Viken Nighthawk-HBI Operation
10497 10497 - Select HBI application Instruction 10498 - 10497 - Select HBI application; Remark:10496 STEP: 10498 - 10497 - Select HBI application; Remark:10496
Viken Nighthawk-HBI Operation
10498 10498 - 10497 - Select HBI application; Remark:10496 Procedure Step
10499 10499 - 10494 - Log into the application; Remark:10493 Procedure Step
10500 10500 - 10492 - Acknowledge warnings; Remark:10491 Procedure Step
10501 10501 - Tap Menu icon, select Settings, if needed Instruction 10502 - 10501 - Tap Menu icon, select Settings, if needed; Remark:10518 STEP: 10502 - 10501 - Tap Menu icon, select Settings, if needed; Remark:10518
Viken Nighthawk-HBI Operation
10502 10502 - 10501 - Tap Menu icon, select Settings, if needed; Remark:10518 Procedure Step
10503 10503 - Perform a system check Instruction 10505 - 10503 - Perform a system check; Remark: STEP: 10505 - 10503 - Perform a system check; Remark:
Viken Nighthawk-HBI Operation
10504 10504 - Note : It is recommended to perform a system check if you have not used the instrume... Annotation 10505 - 10503 - Perform a system check; Remark: STEP: 10505 - 10503 - Perform a system check; Remark:
Viken Nighthawk-HBI Operation
10505 10505 - 10503 - Perform a system check; Remark: Procedure Step
10506 10506 - Conduct scan Instruction 10509 - 10506 - Conduct scan; Remark: STEP: 10509 - 10506 - Conduct scan; Remark:
Viken Nighthawk-HBI Operation
10507 10507 - Warning : The HBI should not be used to scan people directly. Never point the instrumen... Annotation 10509 - 10506 - Conduct scan; Remark: STEP: 10509 - 10506 - Conduct scan; Remark:
Viken Nighthawk-HBI Operation
10508 10508 - Warning : Do not stare directly into the red laser beams. Annotation 10509 - 10506 - Conduct scan; Remark: STEP: 10509 - 10506 - Conduct scan; Remark:
Viken Nighthawk-HBI Operation
10509 10509 - 10506 - Conduct scan; Remark: Procedure Step
10510 10510 - Remark 10522 - 10511 - Tap OK on screen; Remark:10510 STEP: 10522 - 10511 - Tap OK on screen; Remark:10510
Viken Nighthawk-HBI Operation
10511 10511 - Tap OK on screen Instruction 10522 - 10511 - Tap OK on screen; Remark:10510 STEP: 10522 - 10511 - Tap OK on screen; Remark:10510
Viken Nighthawk-HBI Operation
10512 10512 - This will take approximately 10 seconds. Remark 10521 - 10513 - Wait for system check to complete; Remark:10512 STEP: 10521 - 10513 - Wait for system check to complete; Remark:10512
Viken Nighthawk-HBI Operation
10513 10513 - Wait for system check to complete Instruction 10521 - 10513 - Wait for system check to complete; Remark:10512 STEP: 10521 - 10513 - Wait for system check to complete; Remark:10512
Viken Nighthawk-HBI Operation
10514 10514 - Viken Nighthawk system check screen YES Remark 10520 - 10515 - Tap YES on screen; Remark:10514 STEP: 10520 - 10515 - Tap YES on screen; Remark:10514
Viken Nighthawk-HBI Operation
10515 10515 - Tap YES on screen Instruction 10520 - 10515 - Tap YES on screen; Remark:10514 STEP: 10520 - 10515 - Tap YES on screen; Remark:10514
Viken Nighthawk-HBI Operation
10516 10516 - Place face down on flat surface. Remark 10519 - 10517 - Place instrument on sample radiation shield; Remark:10516 STEP: 10519 - 10517 - Place instrument on sample radiation shield; Remark:10516
Viken Nighthawk-HBI Operation
10517 10517 - Place instrument on sample radiation shield Instruction 10519 - 10517 - Place instrument on sample radiation shield; Remark:10516 STEP: 10519 - 10517 - Place instrument on sample radiation shield; Remark:10516
Viken Nighthawk-HBI Operation
10518 10518 - The system check screen will automatically pop-up if it has been more than 7 ... Remark 10502 - 10501 - Tap Menu icon, select Settings, if needed; Remark:10518 STEP: 10502 - 10501 - Tap Menu icon, select Settings, if needed; Remark:10518
Viken Nighthawk-HBI Operation
10519 10519 - 10517 - Place instrument on sample radiation shield; Remark:10516 Procedure Step
10520 10520 - 10515 - Tap YES on screen; Remark:10514 Procedure Step
10521 10521 - 10513 - Wait for system check to complete; Remark:10512 Procedure Step
10522 10522 - 10511 - Tap OK on screen; Remark:10510 Procedure Step
10523 10523 - Press the Power button for 1 second. Remark 10525 - 313 - Power off instrument; Remark:10523 STEP: 10525 - 313 - Power off instrument; Remark:10523
Viken Nighthawk-HBI Operation
10525 10525 - 313 - Power off instrument; Remark:10523 Procedure Step
10526 10526 - The instrument will need to be re-armed. Repeat steps 3-2 to 3-4. Remark 10543 - 10527 - Start new scan, if needed; Remark:10526 STEP: 10543 - 10527 - Start new scan, if needed; Remark:10526
Viken Nighthawk-HBI Operation
10527 10527 - Start new scan, if needed Instruction 10543 - 10527 - Start new scan, if needed; Remark:10526 STEP: 10543 - 10527 - Start new scan, if needed; Remark:10526
Viken Nighthawk-HBI Operation
10528 10528 - The instrument must be moved to capture a two (2)-dimensional image. Moving t... Remark 10542 - 10530 - Scan item of interest; Remark:10528 STEP: 10542 - 10530 - Scan item of interest; Remark:10528
Viken Nighthawk-HBI Operation
10529 10529 - Remark 10542 - 10530 - Scan item of interest; Remark:10528 STEP: 10542 - 10530 - Scan item of interest; Remark:10528
Viken Nighthawk-HBI Operation
10530 10530 - Scan item of interest Instruction 10542 - 10530 - Scan item of interest; Remark:10528 STEP: 10542 - 10530 - Scan item of interest; Remark:10528
Viken Nighthawk-HBI Operation
10531 10531 - Note : Longer scan times produce larger image files, shorter scans are preferred. Annotation 10542 - 10530 - Scan item of interest; Remark:10528 STEP: 10542 - 10530 - Scan item of interest; Remark:10528
Viken Nighthawk-HBI Operation
10532 10532 - Note : There is a 30 second maximum scan time. Annotation 10542 - 10530 - Scan item of interest; Remark:10528 STEP: 10542 - 10530 - Scan item of interest; Remark:10528
Viken Nighthawk-HBI Operation
10533 10533 - Note : Multiple scans may be required to fully image an item. Annotation 10542 - 10530 - Scan item of interest; Remark:10528 STEP: 10542 - 10530 - Scan item of interest; Remark:10528
Viken Nighthawk-HBI Operation
10534 10534 - The triggers may be red or blue, depending on the model. The HBI will start t... Remark 10541 - 10535 - Press and hold the triggers; Remark:10534 STEP: 10541 - 10535 - Press and hold the triggers; Remark:10534
Viken Nighthawk-HBI Operation
10535 10535 - Press and hold the triggers Instruction 10541 - 10535 - Press and hold the triggers; Remark:10534 STEP: 10541 - 10535 - Press and hold the triggers; Remark:10534
Viken Nighthawk-HBI Operation
10536 10536 - The blue slider at the top of the screen must be swiped to the right edge of ... Remark 10540 - 10537 - Swipe slider to the right or touch the right side of the line; Remark:10536 STEP: 10540 - 10537 - Swipe slider to the right or touch the right side of the line; Remark:10536
Viken Nighthawk-HBI Operation
10537 10537 - Swipe slider to the right or touch the right side of the line Instruction 10540 - 10537 - Swipe slider to the right or touch the right side of the line; Remark:10536 STEP: 10540 - 10537 - Swipe slider to the right or touch the right side of the line; Remark:10536
Viken Nighthawk-HBI Operation
10538 10538 - Position instrument over item to be scanned Instruction 10539 - 10538 - Position instrument over item to be scanned; Remark: STEP: 10539 - 10538 - Position instrument over item to be scanned; Remark:
Viken Nighthawk-HBI Operation
10539 10539 - 10538 - Position instrument over item to be scanned; Remark: Procedure Step
10540 10540 - 10537 - Swipe slider to the right or touch the right side of the line; Remark:10536 Procedure Step
10541 10541 - 10535 - Press and hold the triggers; Remark:10534 Procedure Step
10542 10542 - 10530 - Scan item of interest; Remark:10528 Procedure Step
10543 10543 - 10527 - Start new scan, if needed; Remark:10526 Procedure Step
10544 10544 - Remark
10545 10545 - No radiation symbol Remark 2700 - 219 - Verify there are no sources of radiation near instrument; Remark:10545
10549 10549 - Troubleshooting Walkthrough Troubleshoot Element Text 10551 - 10549 - Troubleshooting Walkthrough - Begin, Notes: 10550
10550 10550 - Placeholder for SE CAS camera(s) offline flowchart. A full troubleshooting wa... Remark
10552 10552 - Troubleshooting Guide Troubleshoot Element Text 10553 - 10552 - Troubleshooting Guide - Begin, Notes:
10565 10565 - Are Nanocontroller input voltages correct? Troubleshoot Element Text 10569 - 10565 - Are Nanocontroller input voltages correct? - Decision, Notes: 10566
10605 - 10565 - Are Nanocontroller input voltages correct? - Decision, Notes: 10566
STEP: 10569 - 10565 - Are Nanocontroller input voltages correct? - Decision, Notes: 10566
Rapiscan RPM VM-250, TM-850 Troubleshooting

STEP: 10605 - 10565 - Are Nanocontroller input voltages correct? - Decision, Notes: 10566
Rapiscan RPM VM-250, TM-850 Troubleshooting
Rapiscan RPM VM-250, TM-850 Troubleshooting
10566 10566 - When occupied, voltages should be +15 VDC Remark
10567 10567 - Measure the voltages at the Nanocontroller inputs I1 and I2 Remark
10568 10568 - Are both input voltages +15 VDC? Remark
10570 10570 - +15 VDC present at IR sensors? Troubleshoot Element Text 10573 - 10570 - +15 VDC present at IR sensors? - Decision, Notes: 9041
10607 - 10570 - +15 VDC present at IR sensors? - Decision, Notes: 9041
STEP: 10573 - 10570 - +15 VDC present at IR sensors? - Decision, Notes: 9041
Rapiscan RPM VM-250, TM-850 Troubleshooting

STEP: 10607 - 10570 - +15 VDC present at IR sensors? - Decision, Notes: 9041
Rapiscan RPM VM-250, TM-850 Troubleshooting
Rapiscan RPM VM-250, TM-850 Troubleshooting
10571 10571 - Verify +15 VDC is applied to all sensors: Vehicle Monitor: Remark
10572 10572 - Is +15 VDC present at all sensors? Remark
10574 10574 - Measure the occupancy signal input voltage from the control pillar&nb... Remark
10578 10578 - Both IN LEDs Illuminated? Troubleshoot Element Text 10580 - 10578 - Both IN LEDs Illuminated? - Decision, Notes: 10097
10608 - 10578 - Both IN LEDs Illuminated? - Decision, Notes: 10097
STEP: 10580 - 10578 - Both IN LEDs Illuminated? - Decision, Notes: 10097
Rapiscan RPM VM-250, TM-850 Troubleshooting

STEP: 10608 - 10578 - Both IN LEDs Illuminated? - Decision, Notes: 10097
Rapiscan RPM VM-250, TM-850 Troubleshooting
Rapiscan RPM VM-250, TM-850 Troubleshooting
10579 10579 - Are both IN LEDs Illuminated? Remark
10581 10581 - RUN and OK LEDs Illuminated? Troubleshoot Element Text 10583 - 10581 - RUN and OK LEDs Illuminated? - Decision, Notes: 10097
10609 - 10581 - RUN and OK LEDs Illuminated? - Decision, Notes: 10097
STEP: 10583 - 10581 - RUN and OK LEDs Illuminated? - Decision, Notes: 10097
Rapiscan RPM VM-250, TM-850 Troubleshooting

STEP: 10609 - 10581 - RUN and OK LEDs Illuminated? - Decision, Notes: 10097
Rapiscan RPM VM-250, TM-850 Troubleshooting
Rapiscan RPM VM-250, TM-850 Troubleshooting
10582 10582 - Are both the OK and RUN LEDs Illuminated? Remark
10584 10584 - PWR LED on Nanocontroller Illuminated? Troubleshoot Element Text 10586 - 10584 - PWR LED on Nanocontroller Illuminated? - Decision, Notes: 10097
10610 - 10584 - PWR LED on Nanocontroller Illuminated? - Decision, Notes: 10097
STEP: 10586 - 10584 - PWR LED on Nanocontroller Illuminated? - Decision, Notes: 10097
Rapiscan RPM VM-250, TM-850 Troubleshooting

STEP: 10610 - 10584 - PWR LED on Nanocontroller Illuminated? - Decision, Notes: 10097
Rapiscan RPM VM-250, TM-850 Troubleshooting
Rapiscan RPM VM-250, TM-850 Troubleshooting
10585 10585 - Is the PWR LED Illuminated? Remark
10587 10587 - Initiate an OCCUPIED condition by: Vehicle M... Remark
10588 10588 - Verify the SC-770 controller displays OCCUPIED. Remark
10590 10590 - Connect NMT to SC-770 output and use the Data Capture feature or verify with ... Remark
10592 10592 - Note : It would be extremely unlikely for both IR Occupancy sensor pairs to be fault... Annotation 10086 - 10084 - Replace Banner IR Occupancy Sensor - Formal Procedure, Notes: 9007
10593 - 10084 - Replace Banner IR Occupancy Sensor - Formal Procedure, Notes: 9007
STEP: 10086 - 10084 - Replace Banner IR Occupancy Sensor - Formal Procedure, Notes: 9007
Rapiscan RPM VM-250, TM-850 Troubleshooting
Rapiscan RPM VM-250, TM-850 Troubleshooting

STEP: 10593 - 10084 - Replace Banner IR Occupancy Sensor - Formal Procedure, Notes: 9007
Rapiscan RPM VM-250, TM-850 Troubleshooting
Rapiscan RPM VM-250, TM-850 Troubleshooting
10596 10596 - Replace RS232 to RS485 converter Troubleshoot Element Text 10598 - 10596 - Replace RS232 to RS485 converter - Formal Procedure, Notes: 9007 STEP: 10598 - 10596 - Replace RS232 to RS485 converter - Formal Procedure, Notes: 9007
Rapiscan RPM VM-250, TM-850 Troubleshooting
Rapiscan RPM VM-250, TM-850 Troubleshooting
10597 10597 - DET-RPM-RAP-CM17, RPM RS232 to RS485 Converter Replacement Remark
10602 10602 - Check wiring from nanocontroller output to SC-770 controller input ... Remark
10606 10606 - Note : In rare cases, the IR receivers are installed in the auxiliary pillar, and em... Annotation 10573 - 10570 - +15 VDC present at IR sensors? - Decision, Notes: 9041
10607 - 10570 - +15 VDC present at IR sensors? - Decision, Notes: 9041
STEP: 10573 - 10570 - +15 VDC present at IR sensors? - Decision, Notes: 9041
Rapiscan RPM VM-250, TM-850 Troubleshooting

STEP: 10607 - 10570 - +15 VDC present at IR sensors? - Decision, Notes: 9041
Rapiscan RPM VM-250, TM-850 Troubleshooting
Rapiscan RPM VM-250, TM-850 Troubleshooting
10630 10630 - Instruction 10631 - 10630 -; Remark: STEP: 10631 - 10630 -; Remark:
TEST
10631 10631 - 10630 -; Remark: Procedure Step
10638 10638 - VeriFinder Acknowledge Alarm Choice Remark 2449 - 2377 - Press POWER/SELECT to acknowledge alarm, if necessary; Remark:2409 STEP: 2449 - 2377 - Press POWER/SELECT to acknowledge alarm, if necessary; Remark:2409
VeriFinder Operation
10646 10646 - Localize source of radiation Instruction 10647 - 10646 - Lokalizujte zdroj záření; Remark:386
10702 - 10646 - Localize source of radiation; Remark:386
STEP: 10647 - 10646 - Lokalizujte zdroj záření; Remark:386
Handheld Radiation Monitor Operation

STEP: 10702 - 10646 - Localize source of radiation; Remark:386
radEAGLET Operation