Rapiscan PRM-470 CG |
Device
|
Published
|
10/28/2024 3:40 PM
|
Rapiscan PRM-470 CGN |
Device
|
Published
|
10/28/2024 3:33 PM
|
247 - 257 - Prepare instrument; Remark: |
Procedure Step
|
Published
|
04/11/2025 9:08 PM
|
257 - Prepare instrument |
Instruction
|
Published
|
04/11/2025 9:07 PM
|
607 - 205 - Disconnect charger; Remark: |
Procedure Step
|
Published
|
07/23/2021 2:42 PM
|
205 - Disconnect charger |
Instruction
|
Published
|
07/23/2021 2:42 PM
|
260 - 313 - Power off instrument; Remark: |
Procedure Step
|
Published
|
07/23/2021 2:43 PM
|
313 - Power off instrument |
Instruction
|
Published
|
07/23/2021 2:41 PM
|
261 - 65 - Loosen four (4) cover screws; Remark:264 |
Procedure Step
|
Published
|
08/12/2021 7:25 AM
|
65 - Loosen four (4) cover screws |
Instruction
|
Published
|
07/22/2021 12:38 PM
|
264 - Use a medium Phillips (PH2) screwdriver. Screws do not need to be completely ... |
Remark
|
Published
|
07/20/2021 3:59 PM
|
263 - 262 - Remove instrument cover; Remark:413 |
Procedure Step
|
Published
|
08/11/2021 1:41 PM
|
2771 - Note : There are high-voltage detector circuit boards inside the instrument; however... |
Annotation
|
Published
|
10/04/2022 11:06 AM
|
262 - Remove instrument cover |
Instruction
|
Published
|
07/20/2021 3:35 PM
|
413 - PRM-470 Remove Instrument Cover |
Remark
|
Published
|
11/01/2024 8:32 PM
|
267 - 266 - Locate battery connection; Remark:272 |
Procedure Step
|
Published
|
08/11/2021 1:42 PM
|
3033 - Note : PRM-470 CGN models have an additional board and connectors not shown in remar... |
Annotation
|
Published
|
10/04/2022 11:07 AM
|
266 - Locate battery connection |
Instruction
|
Published
|
07/20/2021 3:36 PM
|
272 - Battery connection is labeled 1. |
Remark
|
Published
|
07/21/2021 12:11 PM
|
271 - 270 - Disconnect battery; Remark:414 |
Procedure Step
|
Published
|
08/11/2021 1:42 PM
|
1345 - Note : It is good practice to ensure all cables and connectors are labeled prior to ... |
Annotation
|
Published
|
10/04/2022 11:08 AM
|
270 - Disconnect battery |
Instruction
|
Published
|
07/20/2021 3:37 PM
|
414 - PRM-470_Disconnect_battery |
Remark
|
Published
|
11/02/2024 1:21 PM
|
443 - 442 - Disconnect remaining connectors; Remark: |
Procedure Step
|
Published
|
08/11/2021 1:43 PM
|
442 - Disconnect remaining connectors |
Instruction
|
Published
|
07/22/2021 12:39 PM
|
618 - 615 - Uninstall PRCB-472 board; Remark: |
Procedure Step
|
Published
|
08/12/2021 7:16 AM
|
615 - Uninstall PRCB-472 board |
Instruction
|
Published
|
08/07/2021 11:00 AM
|
446 - 445 - Remove four (4) mounting screws; Remark:444 |
Procedure Step
|
Published
|
08/11/2021 1:43 PM
|
445 - Remove four (4) mounting screws |
Instruction
|
Published
|
07/22/2021 12:41 PM
|
444 - Use a small Phillips (PH1) screwdriver. Retain screws. |
Remark
|
Published
|
07/22/2021 1:19 PM
|
450 - 449 - Raise edge of PRCB-472 board to access underside; Remark:448 |
Procedure Step
|
Published
|
08/11/2021 1:48 PM
|
447 - Caution : Do not damage ribbon cable attached to the underside of PRCB-472. |
Annotation
|
Published
|
10/04/2022 11:11 AM
|
449 - Raise edge of PRCB-472 board to access underside |
Instruction
|
Published
|
07/22/2021 12:42 PM
|
448 - PRM-470 Lifting PRCB-472 circuit board |
Remark
|
Published
|
11/02/2024 4:30 PM
|
453 - 452 - Disconnect overlay button connector; Remark:451 |
Procedure Step
|
Published
|
08/11/2021 1:48 PM
|
452 - Disconnect overlay button connector |
Instruction
|
Published
|
07/22/2021 12:43 PM
|
451 - PRM-470 Display circuit board |
Remark
|
Published
|
11/02/2024 3:35 PM
|
595 - 572 - Remove four (4) cover screws; Remark:594 |
Procedure Step
|
Published
|
08/12/2021 7:26 AM
|
572 - Remove four (4) cover screws |
Instruction
|
Published
|
08/09/2021 1:57 PM
|
594 - Completely remove screws by continuing to thread them out of the front cover.... |
Remark
|
Published
|
08/12/2021 7:34 AM
|
596 - IO PRM-470 Cover Held by 4 screws exposed |
Remark
|
Published
|
11/02/2024 4:33 PM
|
597 - 573 - Remove two (2) handle mounting screws; Remark:593 |
Procedure Step
|
Published
|
08/12/2021 7:26 AM
|
573 - Remove two (2) handle mounting screws |
Instruction
|
Published
|
08/09/2021 1:58 PM
|
593 - Use a medium Phillips screwdriver (PH2). Retain screws. |
Remark
|
Published
|
08/11/2021 11:19 AM
|
598 - 574 - Uninstall faulty overlay; Remark: |
Procedure Step
|
Published
|
08/12/2021 7:27 AM
|
574 - Uninstall faulty overlay |
Instruction
|
Published
|
08/09/2021 1:59 PM
|
599 - 575 - Peel off faulty overlay; Remark:592 |
Procedure Step
|
Published
|
08/12/2021 7:27 AM
|
575 - Peel off faulty overlay |
Instruction
|
Published
|
08/09/2021 2:00 PM
|
592 - Use a scraping tool or blade to begin. The overlay has two (2) layers. Verify... |
Remark
|
Published
|
08/11/2021 11:21 AM
|
600 - 576 - Clean case cover; Remark:591 |
Procedure Step
|
Published
|
08/12/2021 7:28 AM
|
576 - Clean case cover |
Instruction
|
Published
|
08/11/2021 11:24 AM
|
591 - Use scraper, adhesive remover, and rags to remove excess adhesive. |
Remark
|
Published
|
08/11/2021 11:28 AM
|
601 - 580 - Install new button overlay; Remark: |
Procedure Step
|
Published
|
08/12/2021 7:28 AM
|
580 - Install new button overlay |
Instruction
|
Published
|
08/09/2021 2:03 PM
|
602 - 577 - Expose adhesive; Remark:590 |
Procedure Step
|
Published
|
08/12/2021 7:29 AM
|
577 - Expose adhesive |
Instruction
|
Published
|
08/09/2021 2:04 PM
|
590 - Peel protective layer from new overlay. |
Remark
|
Published
|
08/11/2021 11:29 AM
|
603 - 578 - Feed overlay button connector through slot; Remark:589 |
Procedure Step
|
Published
|
08/12/2021 7:29 AM
|
578 - Feed overlay button connector through slot |
Instruction
|
Published
|
08/09/2021 2:05 PM
|
589 - IO Overlay of PRM-470 Wire Ribbon Slot |
Remark
|
Published
|
11/02/2024 4:35 PM
|
708 - 579 - Apply overlay to cover; Remark:707 |
Procedure Step
|
Published
|
08/12/2021 7:31 AM
|
579 - Apply overlay to cover |
Instruction
|
Published
|
08/09/2021 2:05 PM
|
707 - Align holes for screws and LEDs. |
Remark
|
Published
|
08/11/2021 11:30 AM
|
604 - 581 - Pull connector through slot; Remark:587 |
Procedure Step
|
Published
|
08/12/2021 7:30 AM
|
581 - Pull connector through slot |
Instruction
|
Published
|
08/09/2021 2:06 PM
|
587 - Overlay should be flat against the case. |
Remark
|
Published
|
08/11/2021 11:32 AM
|
605 - 582 - Verify overlay is securely attached; Remark:586 |
Procedure Step
|
Published
|
08/12/2021 7:31 AM
|
582 - Verify overlay is securely attached |
Instruction
|
Published
|
08/09/2021 2:07 PM
|
586 - Apply pressure over entire overlay to ensure contact with cover. |
Remark
|
Published
|
08/11/2021 11:34 AM
|
303 - 302 - Reassemble instrument; Remark: |
Procedure Step
|
Published
|
10/07/2022 1:49 PM
|
302 - Reassemble instrument |
Instruction
|
Published
|
06/16/2021 11:28 PM
|
709 - 583 - Reattach handle; Remark:585 |
Procedure Step
|
Published
|
08/12/2021 7:32 AM
|
583 - Reattach handle |
Instruction
|
Published
|
08/09/2021 2:08 PM
|
585 - Use a medium Phillips screwdriver (PH2). |
Remark
|
Published
|
08/11/2021 11:37 AM
|
710 - 584 - Reinsert four (4) assembly screws; Remark:596 |
Procedure Step
|
Published
|
08/12/2021 7:32 AM
|
584 - Reinsert four (4) assembly screws |
Instruction
|
Published
|
08/09/2021 2:09 PM
|
465 - 463 - Reconnect overlay button connector; Remark:464 |
Procedure Step
|
Published
|
08/11/2021 1:51 PM
|
462 - Caution : Correct placement of connectors and wiring is critical to proper operation. |
Annotation
|
Published
|
09/28/2023 2:13 PM
|
463 - Reconnect overlay button connector |
Instruction
|
Published
|
07/22/2021 12:50 PM
|
464 - PRM-470 - Connecting ribbon cable to overlay button connector |
Remark
|
Published
|
11/02/2024 3:35 PM
|
470 - 468 - Set PRCB-472 board over mounting posts; Remark:469 |
Procedure Step
|
Published
|
08/11/2021 1:52 PM
|
468 - Set PRCB-472 board over mounting posts |
Instruction
|
Published
|
07/22/2021 12:52 PM
|
469 - Position ribbon cable to avoid obstructing PRCB-472 mounting hole. |
Remark
|
Published
|
07/22/2021 1:12 PM
|
473 - 471 - Reinstall four (4) mounting screws; Remark:472 |
Procedure Step
|
Published
|
08/11/2021 1:53 PM
|
471 - Reinstall four (4) mounting screws |
Instruction
|
Published
|
07/22/2021 12:53 PM
|
472 - Use a small Phillips (PH1) screwdriver. |
Remark
|
Published
|
07/22/2021 1:13 PM
|
500 - 498 - Reconnect all connectors except battery; Remark:499 |
Procedure Step
|
Published
|
08/11/2021 2:02 PM
|
498 - Reconnect all connectors except battery |
Instruction
|
Published
|
07/22/2021 1:02 PM
|
499 - Do not connect location 1. |
Remark
|
Published
|
07/22/2021 1:17 PM
|
306 - 305 - Reconnect battery; Remark:416 |
Procedure Step
|
Published
|
08/11/2021 3:11 PM
|
305 - Reconnect battery |
Instruction
|
Published
|
07/29/2021 3:48 PM
|
416 - PRM-470 Battery Replacement - Reconnect battery |
Remark
|
Published
|
11/02/2024 2:02 PM
|
308 - 307 - Replace front cover; Remark: |
Procedure Step
|
Published
|
08/11/2021 2:03 PM
|
304 - Caution : Ensure all wiring is inside the instrument while replacing cover. |
Annotation
|
Published
|
10/04/2022 11:10 AM
|
307 - Replace front cover |
Instruction
|
Published
|
07/20/2021 3:57 PM
|
310 - 309 - Tighten four (4) cover screws; Remark:417 |
Procedure Step
|
Published
|
08/11/2021 2:04 PM
|
569 - Caution : Do not overtighten screws. |
Annotation
|
Published
|
06/16/2021 2:31 PM
|
309 - Tighten four (4) cover screws |
Instruction
|
Published
|
07/22/2021 1:02 PM
|
417 - Use a medium Phillips (PH2) screwdriver. |
Remark
|
Published
|
07/22/2021 1:18 PM
|
359 - 319 - Perform operational test; Remark:347 |
Procedure Step
|
Published
|
07/20/2021 10:55 AM
|
319 - Perform operational test |
Instruction
|
Published
|
06/10/2021 8:31 PM
|
347 - Perform DET-HHD-RAP-RM01 PRM-470 Operational Test. |
Remark
|
Published
|
07/21/2021 12:22 PM
|
322 - 321 - Document maintenance actions; Remark: |
Procedure Step
|
Published
|
06/17/2021 9:49 AM
|
321 - Document maintenance actions |
Instruction
|
Published
|
04/21/2025 11:19 AM
|
2869 - 2585 - Document maintenance performed; Remark:2866 |
Procedure Step
|
Published
|
06/18/2021 5:58 PM
|
2585 - Document maintenance performed |
Instruction
|
Published
|
07/09/2021 12:15 PM
|
2866 - Record observations, times, and results for the maintenance report. |
Remark
|
Published
|
04/21/2025 11:39 AM
|
4706 - 4705 - Submit report; Remark:4864 |
Procedure Step
|
Published
|
06/29/2022 9:50 AM
|
4705 - Submit report |
Instruction
|
Published
|
06/29/2022 9:50 AM
|
4864 - As specified by management or contractual obligations. |
Remark
|
Published
|
07/28/2022 1:36 PM
|
Corrective Maintenance Procedure |
Document Type
|
Published
|
03/02/2020 3:32 PM
|
45 minutes |
Duration
|
Published
|
05/18/2020 12:58 PM
|
As Needed |
Frequency
|
Published
|
04/01/2020 11:36 AM
|
Note |
Annotation Type
|
Published
|
03/02/2020 3:25 PM
|
Caution |
Annotation Type
|
Published
|
03/02/2020 3:24 PM
|
Technician 2 |
Skill Level
|
Published
|
04/09/2020 1:17 AM
|
Medium Phillips (PH2) screwdriver |
Tools
|
Published
|
04/24/2020 4:40 PM
|
Small Phillips (PH1) screwdriver |
Tools
|
Published
|
05/14/2020 2:48 PM
|
Needle nose pliers |
Tools
|
Published
|
05/06/2020 4:10 PM
|
Scraping tool or blade |
Tools
|
Published
|
05/14/2020 2:49 PM
|
PRM470_Remove_Screws_Top_Case |
படம்
|
Published
|
05/08/2020 6:05 PM
|
PRM-470_di_CGN_open_00536 |
படம்
|
Published
|
02/19/2023 11:26 AM
|
Battery_connection_is_labeled_1 |
படம்
|
Published
|
02/19/2023 10:46 AM
|
PRM-470_Disconnect_battery |
படம்
|
Published
|
05/09/2020 8:40 PM
|
PRM-470 Remove four mounting screws on PRCB-472 |
படம்
|
Published
|
05/11/2020 7:57 PM
|
PRM-470_Raise_edge_of _PRCB-472_board_gamma_on |
படம்
|
Published
|
05/20/2020 2:04 PM
|
PRM-470 Remove ribbon cable from PRCB-472 LCD Functional |
படம்
|
Published
|
05/20/2020 10:03 AM
|
PRM-470 Cover Screw Total Extraction |
படம்
|
Published
|
05/14/2020 5:50 PM
|
PRM-470 Handle Screws Interior |
படம்
|
Published
|
05/14/2020 6:59 PM
|
PRM-470 Handle Removal Exterior |
படம்
|
Published
|
05/14/2020 5:55 PM
|
PRM-470 Overlay Remove 1 with Scraper |
படம்
|
Published
|
05/14/2020 5:57 PM
|
PRM-470 Overlay Remove 2 |
படம்
|
Published
|
05/14/2020 5:59 PM
|
PRM-470 Overlay Remove 3 |
படம்
|
Published
|
05/14/2020 6:01 PM
|
PRM-470 Overlay Install Wire Ribbon Slot |
படம்
|
Published
|
05/14/2020 6:04 PM
|
PRM-470 Overlay Install Align to Cover |
படம்
|
Published
|
05/14/2020 6:07 PM
|
PRM-470 Overlay Flatten to Cover |
படம்
|
Published
|
05/14/2020 6:09 PM
|
PRM-470 - Connecting ribbon cable to overlay button connector |
படம்
|
Published
|
05/12/2020 12:56 PM
|
PRM-470_Set_PRCB-472_board_gamma_on |
படம்
|
Published
|
05/20/2020 2:13 PM
|
Remove metal brackets |
படம்
|
Published
|
09/08/2023 2:50 PM
|
Remove metal brackets 2 |
படம்
|
Published
|
09/08/2023 2:51 PM
|
PRM470_Battery_connection_is_labeled_1 |
படம்
|
Published
|
02/19/2023 10:40 AM
|
PRM-470_Reconnect_battery |
படம்
|
Published
|
05/10/2020 8:16 PM
|
PRM-470_Tighten_4_cover_screws |
படம்
|
Published
|