Rapiscan VM-250 Vehicle Monitor |
Device
|
Published
|
10/14/2024 9:50 AM
|
Rapiscan PM-700 Pedestrian Monitor |
Device
|
Published
|
06/20/2024 11:38 AM
|
Rapiscan TM-850 Rail Monitor |
Device
|
Published
|
09/18/2024 10:28 AM
|
7621 - 1401 - Establish Initial Conditions; Remark: |
Procedure Step
|
Published
|
06/29/2023 5:37 PM
|
1401 - Establish Initial Conditions |
Instruction
|
Published
|
09/30/2022 3:14 PM
|
7622 - 7592 - Inform system operators; Remark:11335 |
Procedure Step
|
Published
|
04/20/2025 10:15 AM
|
7592 - Inform system operators |
Instruction
|
Published
|
06/29/2023 3:20 PM
|
11335 - Upon arrival, brief system operators on expected work, duration, anticipated ... |
Remark
|
Published
|
04/20/2025 10:14 AM
|
7623 - 7593 - Brief system operators on expected work and duration before starting work&nbs...; Remark: |
Procedure Step
|
Published
|
06/29/2023 4:56 PM
|
7593 - Brief system operators on expected work and duration before starting work&nbs... |
Instruction
|
Published
|
06/29/2023 3:22 PM
|
7624 - 7594 - Close lane and set up barriers to establish a safety watch; Remark:7595 |
Procedure Step
|
Published
|
06/29/2023 4:57 PM
|
7594 - Close lane and set up barriers to establish a safety watch |
Instruction
|
Published
|
06/29/2023 3:28 PM
|
7595 - Use orange safety (traffic control) cones or equivalent per site-specific saf... |
Remark
|
Published
|
06/29/2023 3:33 PM
|
7625 - 7596 - Perform +12 VDC Battery Load Test; Remark: |
Procedure Step
|
Published
|
06/29/2023 4:58 PM
|
7596 - Perform +12 VDC Battery Load Test |
Instruction
|
Published
|
06/29/2023 3:38 PM
|
7626 - 7597 - Unlock and open RPM cabinets doors as required to access cabinet interior...; Remark: |
Procedure Step
|
Published
|
06/29/2023 4:59 PM
|
7597 - Unlock and open RPM cabinets doors as required to access cabinet interior... |
Instruction
|
Published
|
06/29/2023 3:40 PM
|
7270 - 7235 - Power off RPM; Remark:7236 |
Procedure Step
|
Published
|
09/01/2023 7:57 PM
|
7235 - Power off RPM |
Instruction
|
Published
|
04/24/2023 12:30 PM
|
7236 - Move LD-260 switch to OFF position. The PWR ON |
Remark
|
Published
|
04/27/2023 4:25 PM
|
7629 - 7600 - Switch ac power off so green window is visible; Remark:7628 |
Procedure Step
|
Published
|
04/13/2025 6:19 PM
|
7599 - Warning : 120/220 Vac will be present at the input side of the ac circuit breaker. ... |
Annotation
|
Published
|
06/29/2023 3:43 PM
|
7600 - Switch ac power off so green window is visible |
Instruction
|
Published
|
04/13/2025 5:48 PM
|
7628 - Breaker Off |
Remark
|
Published
|
06/29/2023 5:01 PM
|
7280 - 7250 - Power on RPM; Remark:7251 |
Procedure Step
|
Published
|
04/27/2023 4:14 PM
|
7250 - Power on RPM |
Instruction
|
Published
|
05/01/2023 8:31 AM
|
7251 - Move LD-260 switch to ON position. The LED PWR ON |
Remark
|
Published
|
05/10/2023 3:14 PM
|
11339 - 6914 - Verify battery operation; Remark:11338 |
Procedure Step
|
Published
|
04/20/2025 1:30 PM
|
6914 - Verify battery operation |
Instruction
|
Published
|
12/21/2022 12:41 PM
|
11338 - If the RPM does not power on, replace battery by performing procedure ... |
Remark
|
Published
|
04/20/2025 1:28 PM
|
7633 - 7606 - Measure and record battery voltage; Remark:7632 |
Procedure Step
|
Published
|
06/29/2023 5:09 PM
|
7605 - Standard : Using a DMM, the battery voltage should be approximately 12 to 13 VDC. |
Annotation
|
Published
|
06/29/2023 4:01 PM
|
7606 - Measure and record battery voltage |
Instruction
|
Published
|
06/29/2023 4:02 PM
|
7632 - VDC Battery |
Remark
|
Published
|
06/29/2023 5:09 PM
|
7634 - 7607 - Wait approximately 1 hour; Remark: |
Procedure Step
|
Published
|
06/29/2023 5:10 PM
|
7607 - Wait approximately 1 hour |
Instruction
|
Published
|
06/29/2023 4:05 PM
|
7635 - 7608 - Re-measure battery voltage; Remark:7609 |
Procedure Step
|
Published
|
06/29/2023 5:11 PM
|
7608 - Re-measure battery voltage |
Instruction
|
Published
|
06/29/2023 4:09 PM
|
7609 - If the battery voltage is less than 11 VDC, replace the battery by performing... |
Remark
|
Published
|
06/29/2023 4:11 PM
|
7636 - 7610 - Switch ac power on so red window is visible; Remark:7611 |
Procedure Step
|
Published
|
06/29/2023 5:12 PM
|
7610 - Switch ac power on so red window is visible |
Instruction
|
Published
|
06/29/2023 4:13 PM
|
7611 - Amber "ac" light on LD-260 should illuminate. |
Remark
|
Published
|
04/13/2025 5:48 PM
|
7637 - 7612 - Close and lock RPM cabinets; Remark: |
Procedure Step
|
Published
|
06/29/2023 5:12 PM
|
7612 - Close and lock RPM cabinets |
Instruction
|
Published
|
06/29/2023 4:23 PM
|
7279 - 7249 - Return equipment to normal operating condition; Remark: |
Procedure Step
|
Published
|
04/27/2023 4:13 PM
|
7249 - Return equipment to normal operating condition |
Instruction
|
Published
|
04/08/2025 3:22 PM
|
7282 - 7254 - Confirm network connection; Remark:7255 |
Procedure Step
|
Published
|
04/27/2023 4:15 PM
|
7254 - Confirm network connection |
Instruction
|
Published
|
04/27/2023 2:22 PM
|
7255 - Contact operators to confirm communications have been reestablished between RPM ... |
Remark
|
Published
|
05/10/2023 3:15 PM
|
7640 - 7616 - Close, reopen, and close cabinet doors to clear all tampers from fault queue; Remark: |
Procedure Step
|
Published
|
06/29/2023 5:17 PM
|
7616 - Close, reopen, and close cabinet doors to clear all tampers from fault queue |
Instruction
|
Published
|
06/29/2023 4:42 PM
|
7641 - 7617 - Open lane; Remark: |
Procedure Step
|
Published
|
06/29/2023 5:17 PM
|
7617 - Open lane |
Instruction
|
Published
|
06/29/2023 4:43 PM
|
7842 - 7820 - Inform system operators upon completion of maintenance action; Remark: |
Procedure Step
|
Published
|
07/07/2023 11:15 PM
|
7820 - Inform system operators upon completion of maintenance action |
Instruction
|
Published
|
07/07/2023 10:02 PM
|
322 - 321 - Document maintenance actions; Remark: |
Procedure Step
|
Published
|
06/17/2021 9:49 AM
|
321 - Document maintenance actions |
Instruction
|
Published
|
04/21/2025 11:19 AM
|
2869 - 2585 - Document maintenance performed; Remark:2866 |
Procedure Step
|
Published
|
06/18/2021 5:58 PM
|
2585 - Document maintenance performed |
Instruction
|
Published
|
07/09/2021 12:15 PM
|
2866 - Record observations, times, and results for the maintenance report. |
Remark
|
Published
|
04/21/2025 11:39 AM
|
4706 - 4705 - Submit report; Remark:4864 |
Procedure Step
|
Published
|
06/29/2022 9:50 AM
|
4705 - Submit report |
Instruction
|
Published
|
06/29/2022 9:50 AM
|
4864 - As specified by management or contractual obligations. |
Remark
|
Published
|
07/28/2022 1:36 PM
|
Routine Maintenance Procedure |
Document Type
|
Published
|
03/02/2020 3:31 PM
|
Semi-annually |
Frequency
|
Published
|
11/03/2022 2:10 PM
|
Warning |
Annotation Type
|
Published
|
03/02/2020 3:25 PM
|
Standard |
Annotation Type
|
Published
|
03/02/2020 3:25 PM
|
Technician 2 |
Skill Level
|
Published
|
04/09/2020 1:17 AM
|
Keys for RPM |
Replacement Parts
|
Published
|
06/20/2023 4:47 PM
|
Reflective safety vest if applicable |
Replacement Parts
|
Published
|
06/29/2023 5:46 PM
|
Safety glasses if applicable |
Replacement Parts
|
Published
|
06/29/2023 5:46 PM
|
Traffic control cones or equivalent |
Replacement Parts
|
Published
|
06/29/2023 5:46 PM
|
Digital multimeter DMM |
Replacement Parts
|
Published
|
06/29/2023 5:46 PM
|
LD-260 Disconnect Switch Power Off |
படம்
|
Published
|
04/24/2023 12:49 PM
|
AC Circuit Breaker Off_0.png |
படம்
|
Published
|
06/29/2023 4:24 PM
|
LD-260 Disconnect Switch Power On |
படம்
|
Published
|
05/04/2023 3:37 PM
|
Battery VDC |
படம்
|
Published
|
06/29/2023 4:04 PM
|
AC Circuit Breaker On_0.png |
படம்
|
Published
|
06/29/2023 4:20 PM
|