1402 - 7927 - Establish Initial Conditions; Remark: |
Procedure Step
|
Published
|
09/30/2022 1:47 PM
|
7927 - Establish Initial Conditions |
Instruction
|
Published
|
07/12/2023 12:23 AM
|
7579 - 7577 - Brief operators on expected work, duration, anticipated fault indicators, and...; Remark:7576 |
Procedure Step
|
Published
|
06/20/2023 4:37 PM
|
7577 - Brief operators on expected work, duration, anticipated fault indicators, and... |
Instruction
|
Published
|
06/20/2023 4:37 PM
|
7576 - Alarms/faults: Operators should expect to receive tamper (TT) fault indicatio... |
Remark
|
Published
|
06/20/2023 4:37 PM
|
7574 - 7572 - Close lane and set up barriers.; Remark:7571 |
Procedure Step
|
Published
|
06/20/2023 4:42 PM
|
7578 - Warning : Vehicle, and/or pedestrian traffic should temporarily be rerouted or halted d... |
Annotation
|
Published
|
06/20/2023 4:37 PM
|
7572 - Close lane and set up barriers. |
Instruction
|
Published
|
06/20/2023 4:39 PM
|
7571 - Use orange safety cones or equivalent based on site-specific safety practices... |
Remark
|
Published
|
06/20/2023 4:42 PM
|
7588 - 7587 - Clean and inspect RPM cabinet exterior; Remark: |
Procedure Step
|
Published
|
06/21/2023 9:49 AM
|
7573 - Note : Perform and document each step in this procedure on a Rapiscan RPM Cleaning a... |
Annotation
|
Published
|
06/20/2023 4:42 PM
|
7575 - Reminder : All discrepancies noted during the performance of this procedure should be co... |
Annotation
|
Published
|
06/20/2023 4:44 PM
|
7587 - Clean and inspect RPM cabinet exterior |
Instruction
|
Published
|
06/21/2023 9:48 AM
|
7585 - 7583 - Inspect exterior for dents, scratches, rust, and bare metal; Remark: |
Procedure Step
|
Published
|
06/21/2023 9:50 AM
|
7583 - Inspect exterior for dents, scratches, rust, and bare metal |
Instruction
|
Published
|
06/21/2023 9:49 AM
|
7586 - 7582 - Lubricate hinges and keyholes; Remark:7581 |
Procedure Step
|
Published
|
06/21/2023 9:51 AM
|
7584 - Note : If rust or bare metal is found, take corrective action. See SLD_Technical Ser... |
Annotation
|
Published
|
06/21/2023 9:50 AM
|
7582 - Lubricate hinges and keyholes |
Instruction
|
Published
|
06/21/2023 9:51 AM
|
7581 - Use of a dry graphite lubricant is recommended. |
Remark
|
Published
|
06/21/2023 9:51 AM
|
7903 - 7902 - Inspect RPM and pedestal bolts and flanges; Remark:7901 |
Procedure Step
|
Published
|
07/11/2023 10:57 PM
|
7902 - Inspect RPM and pedestal bolts and flanges |
Instruction
|
Published
|
07/11/2023 10:56 PM
|
7901 - If loose, tighten the bolts and flanges |
Remark
|
Published
|
07/11/2023 10:57 PM
|
7900 - 7898 - Clean and inspect RPM cabinet interior; Remark: |
Procedure Step
|
Published
|
07/11/2023 11:00 PM
|
7899 - Warning : If standing water is present in the RPM cabinet interior, implement site-spec... |
Annotation
|
Published
|
07/11/2023 11:00 PM
|
7898 - Clean and inspect RPM cabinet interior |
Instruction
|
Published
|
07/11/2023 11:00 PM
|
7894 - 7893 - Inspect interior of RPM cabinets for dirt, debris, and signs of water; Remark: |
Procedure Step
|
Published
|
07/11/2023 11:02 PM
|
7893 - Inspect interior of RPM cabinets for dirt, debris, and signs of water |
Instruction
|
Published
|
07/11/2023 11:01 PM
|
7895 - 7892 - Inspect for cables and wires in neat condition and tied down; Remark: |
Procedure Step
|
Published
|
07/11/2023 11:03 PM
|
7892 - Inspect for cables and wires in neat condition and tied down |
Instruction
|
Published
|
07/11/2023 11:02 PM
|
7896 - 7891 - Inspect desiccant and replace if required; Remark:7890 |
Procedure Step
|
Published
|
07/11/2023 11:03 PM
|
7891 - Inspect desiccant and replace if required |
Instruction
|
Published
|
07/11/2023 11:03 PM
|
7890 - Per DET-RPM-RAP-RM01. |
Remark
|
Published
|
07/11/2023 11:03 PM
|
7897 - 7889 - Inspect battery, cables, and connectors for corrosion and damage; Remark:7888 |
Procedure Step
|
Published
|
07/11/2023 11:04 PM
|
7889 - Inspect battery, cables, and connectors for corrosion and damage |
Instruction
|
Published
|
07/11/2023 11:04 PM
|
7888 - Check for swelling of the battery case and corrosion of battery connections; ... |
Remark
|
Published
|
07/11/2023 11:04 PM
|
7887 - 7886 - Inspect RPM cabinet for moisture intrusion; Remark: |
Procedure Step
|
Published
|
07/11/2023 11:06 PM
|
7886 - Inspect RPM cabinet for moisture intrusion |
Instruction
|
Published
|
07/11/2023 11:06 PM
|
7885 - 7884 - Inspect RPM penetrations for integrity and moisture intrusion such as localiz...; Remark:7883 |
Procedure Step
|
Published
|
07/11/2023 11:20 PM
|
7884 - Inspect RPM penetrations for integrity and moisture intrusion such as localiz... |
Instruction
|
Published
|
07/11/2023 11:09 PM
|
7883 - Panel 1 Check that the cabinet penetrations for the lights, speaker, a... |
Remark
|
Published
|
07/11/2023 11:20 PM
|
7921 - 7920 - Inspect RPM door seals for leakage; Remark:7919 |
Procedure Step
|
Published
|
07/11/2023 11:23 PM
|
7920 - Inspect RPM door seals for leakage |
Instruction
|
Published
|
07/11/2023 11:23 PM
|
7919 - Localized deposit of dust on the inner side of the RPM door is indicative of ... |
Remark
|
Published
|
07/11/2023 11:23 PM
|
7922 - 7918 - Inspect RPM internal surfaces and components for signs of rust and/or mildew; Remark: |
Procedure Step
|
Published
|
07/11/2023 11:24 PM
|
7918 - Inspect RPM internal surfaces and components for signs of rust and/or mildew |
Instruction
|
Published
|
07/11/2023 11:24 PM
|
7279 - 7249 - Return equipment to normal operating condition; Remark: |
Procedure Step
|
Published
|
04/27/2023 4:13 PM
|
7249 - Return equipment to normal operating condition |
Instruction
|
Published
|
04/08/2025 3:22 PM
|
7911 - 7910 - Close doors and lock cabinets; Remark: |
Procedure Step
|
Published
|
07/11/2023 11:26 PM
|
7910 - Close doors and lock cabinets |
Instruction
|
Published
|
07/11/2023 11:26 PM
|
7912 - 7909 - Dispose of waste materials; Remark: |
Procedure Step
|
Published
|
07/11/2023 11:27 PM
|
7909 - Dispose of waste materials |
Instruction
|
Published
|
07/11/2023 11:27 PM
|
7913 - 7908 - Verify RPM is communicating with central alarm station and that all faults ar...; Remark: |
Procedure Step
|
Published
|
07/11/2023 11:27 PM
|
7908 - Verify RPM is communicating with central alarm station and that all faults ar... |
Instruction
|
Published
|
07/11/2023 11:27 PM
|
7842 - 7820 - Inform system operators upon completion of maintenance action; Remark: |
Procedure Step
|
Published
|
07/07/2023 11:15 PM
|
7820 - Inform system operators upon completion of maintenance action |
Instruction
|
Published
|
07/07/2023 10:02 PM
|
322 - 321 - Document maintenance actions; Remark: |
Procedure Step
|
Published
|
06/17/2021 9:49 AM
|
321 - Document maintenance actions |
Instruction
|
Published
|
04/21/2025 11:19 AM
|
2869 - 2585 - Document maintenance performed; Remark:2866 |
Procedure Step
|
Published
|
06/18/2021 5:58 PM
|
2585 - Document maintenance performed |
Instruction
|
Published
|
07/09/2021 12:15 PM
|
2866 - Record observations, times, and results for the maintenance report. |
Remark
|
Published
|
04/21/2025 11:39 AM
|
4706 - 4705 - Submit report; Remark:4864 |
Procedure Step
|
Published
|
06/29/2022 9:50 AM
|
4705 - Submit report |
Instruction
|
Published
|
06/29/2022 9:50 AM
|
4864 - As specified by management or contractual obligations. |
Remark
|
Published
|
07/28/2022 1:36 PM
|
Routine Maintenance Procedure |
Document Type
|
Published
|
03/02/2020 3:31 PM
|
30 minutes |
Duration
|
Published
|
04/01/2020 11:35 AM
|
Quarterly |
Frequency
|
Published
|
08/02/2020 10:39 PM
|
Warning |
Annotation Type
|
Published
|
03/02/2020 3:25 PM
|
Note |
Annotation Type
|
Published
|
03/02/2020 3:25 PM
|
Reminder |
Annotation Type
|
Published
|
04/08/2020 12:21 PM
|
Technician 1 |
Skill Level
|
Published
|
05/14/2020 2:56 PM
|
Keys for RPM |
Replacement Parts
|
Published
|
06/20/2023 4:47 PM
|
Reflective safety vest if required |
Replacement Parts
|
Published
|
06/20/2023 4:47 PM
|
Safety glasses if required |
Replacement Parts
|
Published
|
06/20/2023 4:47 PM
|
Ladder if required |
Replacement Parts
|
Published
|
06/20/2023 4:47 PM
|
Traffic control cones or equivalent if required |
Replacement Parts
|
Published
|
06/20/2023 4:47 PM
|
RPM panel inspect for penetrations or leaking |
படம்
|
Published
|