FHT 681 replacement

PackEye Gamma High Voltage Adjustment

Last Updated: 04/24/2025 1:43 AM

The following table lists all the components that make up the document.

Title Type Status Last Updated
Thermo FHT1377 PackEye
Device
Published
10/28/2024 3:37 PM
6445 - 6444 - Connect to PackEye; Remark:
Procedure Step
Published
11/30/2022 1:47 PM
6444 - Connect to PackEye
Instruction
Published
11/30/2022 1:47 PM
6451 - 6353 - Connect PackEye to Computer; Remark:6450
Procedure Step
Published
11/30/2022 2:06 PM
6353 - Connect PackEye to Computer
Instruction
Published
11/30/2022 10:56 AM
6450 - Refer to DET-HHD-THR-PAK-RM03, PackEye Computer Connection.
Remark
Published
11/30/2022 2:01 PM
6452 - 6449 - Click Settings...; Remark:6448
Procedure Step
Published
11/30/2022 2:34 PM
6449 - Click Settings...
Instruction
Published
11/30/2022 2:07 PM
6448 - IO PackEye Settings Button
Remark
Published
11/09/2024 9:07 PM
6453 - 6447 - Enter Administrator mode; Remark:6446
Procedure Step
Published
11/30/2022 2:50 PM
6447 - Enter Administrator mode
Instruction
Published
11/30/2022 2:48 PM
6446 - Select Options, then Configurations, then
Remark
Published
11/30/2022 2:50 PM
6822 - 6821 - Adjust High Voltage; Remark:
Procedure Step
Published
12/19/2022 2:03 PM
6821 - Adjust High Voltage
Instruction
Published
12/19/2022 2:03 PM
6832 - 6831 - Select HV Adjustment tab; Remark:6830
Procedure Step
Published
12/19/2022 3:35 PM
6831 - Select HV Adjustment tab
Instruction
Published
12/19/2022 3:32 PM
6830 - IO PackEye Interface HV Adjustment
Remark
Published
11/09/2024 9:08 PM
6833 - 6829 - Document current gamma high voltage; Remark:6828
Procedure Step
Published
12/19/2022 3:36 PM
6829 - Document current gamma high voltage
Instruction
Published
12/19/2022 3:36 PM
6828 - IO PackEye Interface Current HV
Remark
Published
11/09/2024 9:08 PM
6834 - 6827 - Select Cs-137; Remark:6826
Procedure Step
Published
12/19/2022 3:38 PM
6827 - Select Cs-137
Instruction
Published
12/19/2022 3:37 PM
6826 - IO PackEye Interface Select Cesium CS-137
Remark
Published
11/16/2024 8:03 PM
6835 - 3828 - Place gamma source on instrument; Remark:6825
Procedure Step
Published
12/19/2022 3:39 PM
3828 - Place gamma source on instrument
Instruction
Published
03/28/2022 6:18 PM
6825 - Gamma source should be located in center of PackEye for best results.
Remark
Published
12/19/2022 3:39 PM
6836 - 6824 - Click Start HV Setup; Remark:6823
Procedure Step
Published
12/19/2022 3:41 PM
6824 - Click Start HV Setup
Instruction
Published
12/19/2022 3:40 PM
6823 - IO PackEye Interface Start HV Setup
Remark
Published
11/16/2024 8:04 PM
6844 - 6843 - Wait for adjustment to complete; Remark:6842
Procedure Step
Published
12/19/2022 4:37 PM
6843 - Wait for adjustment to complete
Instruction
Published
12/19/2022 4:37 PM
6842 - The screen will update and the Status window will be shaded blue.
Remark
Published
12/19/2022 4:37 PM
6845 - 6841 - Click Update HV; Remark:6840
Procedure Step
Published
12/19/2022 4:39 PM
6841 - Click Update HV
Instruction
Published
12/19/2022 4:38 PM
6840 - The Status window will be shaded green when the process is done.
Remark
Published
12/19/2022 4:39 PM
6846 - 6492 - Click Send; Remark:6839
Procedure Step
Published
12/19/2022 4:41 PM
6492 - Click Send
Instruction
Published
12/01/2022 7:46 PM
6839 - This will update the high voltage.
Remark
Published
12/19/2022 4:40 PM
6847 - 6838 - Click OK to close Settings window; Remark:6837
Procedure Step
Published
12/19/2022 5:10 PM
6838 - Click OK to close Settings window
Instruction
Published
12/19/2022 4:42 PM
6837 - IO PackEye Interface OK Close HV
Remark
Published
11/16/2024 8:10 PM
6475 - 6465 - Close FHT 1377 software; Remark:6632
Procedure Step
Published
12/01/2022 12:49 PM
6465 - Close FHT 1377 software
Instruction
Published
12/01/2022 12:46 PM
6632 - Click File, then Exit. Click Yes
Remark
Published
12/08/2022 9:55 AM
6464 - IO PackEye Exit Menu Interface
Remark
Published
11/16/2024 8:10 PM
6441 - 6440 - Restore Instrument Operation; Remark:
Procedure Step
Published
11/30/2022 1:48 PM
6440 - Restore Instrument Operation
Instruction
Published
11/30/2022 1:48 PM
3869 - 313 - Power off instrument; Remark:3850
Procedure Step
Published
03/29/2022 2:23 AM
313 - Power off instrument
Instruction
Published
07/23/2021 2:41 PM
3850 - Press and hold the power button for approximately 10 seconds until indicator ...
Remark
Published
03/29/2022 1:38 AM
6457 - 6456 - Disconnect USB/Serial adapter; Remark:6455
Procedure Step
Published
11/30/2022 3:05 PM
6456 - Disconnect USB/Serial adapter
Instruction
Published
11/30/2022 3:03 PM
6455 - IO PackEye Serial Cable Disconnect
Remark
Published
11/16/2024 8:11 PM
5792 - 5786 - Reconnect RS232 jumper; Remark:5785
Procedure Step
Published
11/03/2022 3:42 PM
5786 - Reconnect RS232 jumper
Instruction
Published
11/03/2022 3:39 PM
5785 - Use small, slotted screwdriver to secure connector.
Remark
Published
11/16/2022 9:35 AM
5830 - IO PackEye RS232 Connect Cable
Remark
Published
11/09/2024 8:14 PM
6458 - 319 - Perform operational test; Remark:6454
Procedure Step
Published
11/30/2022 3:06 PM
319 - Perform operational test
Instruction
Published
06/10/2021 8:31 PM
6454 - DET-HHD-THR-PAK-RM01, PackEye Operational Test.
Remark
Published
11/30/2022 3:06 PM
322 - 321 - Document maintenance actions; Remark:
Procedure Step
Published
06/17/2021 9:49 AM
321 - Document maintenance actions
Instruction
Published
04/21/2025 11:19 AM
2869 - 2585 - Document maintenance performed; Remark:2866
Procedure Step
Published
06/18/2021 5:58 PM
2585 - Document maintenance performed
Instruction
Published
07/09/2021 12:15 PM
2866 - Record observations, times, and results for the maintenance report.
Remark
Published
04/21/2025 11:39 AM
4706 - 4705 - Submit report; Remark:4864
Procedure Step
Published
06/29/2022 9:50 AM
4705 - Submit report
Instruction
Published
06/29/2022 9:50 AM
4864 - As specified by management or contractual obligations.
Remark
Published
07/28/2022 1:36 PM
Routine Maintenance Procedure
Document Type
Published
03/02/2020 3:31 PM
minutes
Duration
Published
05/26/2022 11:41 AM
Annually
Frequency
Published
04/01/2020 11:37 AM
Directed to do so by maintenance support
Frequency
Published
12/19/2022 5:55 PM
FHT 681 replacement
Frequency
Published
12/19/2022 5:54 PM
Gamma detector replacement
Frequency
Published
12/19/2022 5:53 PM
Instrument is not functioning correctly (nuisance alarms)
Frequency
Published
12/19/2022 5:53 PM
Technician 2
Skill Level
Published
04/09/2020 1:17 AM
Computer
Tools
Published
05/09/2020 3:05 PM
FHT 1377 software
Tools
Published
11/30/2022 1:25 PM
USB-A male to RS-232 (DB9) male serial adapter (USB/Serial adapter)
Tools
Published
11/30/2022 1:26 PM
packeye_ui_fhtapp_settings.jpg
படம்
Published
10/23/2023 10:14 AM
packeye_ui_fhtapp_administrator.jpg
படம்
Published
10/23/2023 1:24 PM
packeye_ui_fhtapp_hv_selecttab.jpg
படம்
Published
10/23/2023 1:26 PM
packeye_ui_fhtapp_hv_currentvalue.jpg
படம்
Published
10/23/2023 1:27 PM
packeye_ui_fhtapp_hv_cs137.jpg
படம்
Published
10/23/2023 1:29 PM
packeye_diradsource_placecenter.jpg
படம்
Published
10/23/2023 9:46 AM
packeye_ui_config_hv_startsetup.jpg
படம்
Published
10/23/2023 1:30 PM
packeye_ui_fhtapp_hv_bluescreen.jpg
படம்
Published
10/23/2023 1:31 PM
packeye_ui_fhtapp_hv_greenoptimized.jpg
படம்
Published
10/23/2023 1:33 PM
packeye_ui_fhtapp_sendt1031.jpg
படம்
Published
10/23/2023 1:40 PM
packeye_ui_fhtapp_hv_okclose.jpg
படம்
Published
10/23/2023 1:34 PM
packeye_ui_fhtapp_exit.jpg
படம்
Published
10/23/2023 1:35 PM
Power off Packeye
படம்
Published
02/19/2022 1:48 AM
packeye_di_serialcable_remove.jpg
படம்
Published
10/23/2023 9:51 AM
packeye_di_rs232cable_insert.jpg
படம்
Published
10/23/2023 9:48 AM