RPM SCA-774 Single Channel Analyzer Board Replacement

Last Updated: 05/02/2025 1:43 AM

The following table lists all the components that make up the document.

Title Type Status Last Updated
Rapiscan VM-250 Vehicle Monitor
Device
Published
10/14/2024 9:50 AM
Rapiscan PM-700 Pedestrian Monitor
Device
Published
06/20/2024 11:38 AM
Rapiscan TM-850 Rail Monitor
Device
Published
09/18/2024 10:28 AM
Rapiscan CM-267 Conveyor Monitor
Device
Published
06/27/2024 1:02 PM
7478 - 1401 - Establish Initial Conditions; Remark:
Procedure Step
Published
09/01/2023 7:48 PM
1401 - Establish Initial Conditions
Instruction
Published
09/30/2022 3:14 PM
7823 - 7592 - Inform system operators; Remark:
Procedure Step
Published
07/07/2023 10:54 PM
7592 - Inform system operators
Instruction
Published
06/29/2023 3:20 PM
7824 - 7676 - Brief system operators on expected work, duration, anticipated alarms, and fa...; Remark:7677
Procedure Step
Published
07/07/2023 10:55 PM
7676 - Brief system operators on expected work, duration, anticipated alarms, and fa...
Instruction
Published
07/01/2023 11:39 PM
7677 - Operators should expect numerous fault indications and alarms during procedur...
Remark
Published
07/02/2023 3:05 AM
7825 - 7594 - Close lane and set up barriers to establish a safety watch; Remark:7595
Procedure Step
Published
07/07/2023 10:57 PM
7678 - Warning : Traffic should temporarily be rerouted or halted during conduction of this pr...
Annotation
Published
07/03/2023 10:23 AM
7594 - Close lane and set up barriers to establish a safety watch
Instruction
Published
06/29/2023 3:28 PM
7595 - Use orange safety (traffic control) cones or equivalent per site-specific saf...
Remark
Published
06/29/2023 3:33 PM
7270 - 7235 - Power off RPM; Remark:7236
Procedure Step
Published
09/01/2023 7:57 PM
7235 - Power off RPM
Instruction
Published
04/24/2023 12:30 PM
7236 - Move LD-260 switch to OFF position. The PWR ON
Remark
Published
04/27/2023 4:25 PM
7827 - 7791 - Remove SCA-774 Board; Remark:
Procedure Step
Published
07/07/2023 10:59 PM
7791 - Remove SCA-774 Board
Instruction
Published
07/07/2023 2:14 PM
7828 - 7793 - Disconnect only signal (BNC) cables from SCA-775 module; Remark:7794
Procedure Step
Published
07/07/2023 11:00 PM
7792 - Note : It is good engineering practice to ensure all cables and connectors are label...
Annotation
Published
07/07/2023 2:17 PM
7793 - Disconnect only signal (BNC) cables from SCA-775 module
Instruction
Published
07/07/2023 2:18 PM
7794 - Remove Signal BNC Cables
Remark
Published
07/07/2023 2:22 PM
7829 - 7796 - Loosen screws in each corner (4) using medium Philips screwdriver and open SC...; Remark:7797
Procedure Step
Published
07/07/2023 11:02 PM
7795 - Caution : If you rotate cover of the SCA-775 down without first pulling out from the bo...
Annotation
Published
07/07/2023 2:23 PM
7796 - Loosen screws in each corner (4) using medium Philips screwdriver and open SC...
Instruction
Published
07/07/2023 2:24 PM
7797 - Normally the cover screws are captured and should not come out of cover. ...
Remark
Published
07/07/2023 2:34 PM
9467 - To prevent breaking the hinge on the module / door, once the retainer screws ...
Remark
Published
10/03/2023 3:32 PM
7830 - 7799 - Disconnect 4 wiring harness assembly/connectors (J6, J8, J10, J11) from SCA-7...; Remark:7800
Procedure Step
Published
07/07/2023 11:04 PM
7798 - Caution : Never remove connectors by pulling on wires.
Annotation
Published
07/07/2023 5:41 PM
7799 - Disconnect 4 wiring harness assembly/connectors (J6, J8, J10, J11) from SCA-7...
Instruction
Published
07/07/2023 5:44 PM
7800 - J8 and J11 should be labeled; write J6 and J10 on the appropriate connector i...
Remark
Published
07/07/2023 9:27 PM
7831 - 7801 - Remove 4 screws at corners of board; Remark:7802
Procedure Step
Published
07/07/2023 11:05 PM
7801 - Remove 4 screws at corners of board
Instruction
Published
07/07/2023 9:28 PM
7802 - Do not lose the screws. They are re-used to secure the SCA-774 board.
Remark
Published
07/07/2023 9:31 PM
7832 - 7803 - Remove board from SCA-775 module; Remark:7804
Procedure Step
Published
07/07/2023 11:06 PM
7803 - Remove board from SCA-775 module
Instruction
Published
07/07/2023 9:32 PM
7804 - BNC connectors are attached to the SCA-774 board and easily slide down then o...
Remark
Published
07/07/2023 9:34 PM
3397 - 3395 - Label faulty component; Remark:3396
Procedure Step
Published
07/21/2024 6:59 AM
3395 - Label faulty component
Instruction
Published
08/07/2021 11:07 AM
3396 - Use tag or tape. Include date of removal, description of failure symptoms, co...
Remark
Published
08/09/2021 11:35 AM
7833 - 7805 - Install New SCA-774; Remark:
Procedure Step
Published
07/07/2023 11:06 PM
7805 - Install New SCA-774
Instruction
Published
07/07/2023 9:35 PM
7834 - 7806 - Install new SCA-774 board; Remark:7807
Procedure Step
Published
07/07/2023 11:07 PM
7806 - Install new SCA-774 board
Instruction
Published
07/07/2023 9:36 PM
7807 - Use screws previously removed.
Remark
Published
07/07/2023 9:38 PM
7835 - 7809 - Reconnect 4 wiring harness assembly/connectors (J6, J8, J10, J11) from SCA-77...; Remark:7810
Procedure Step
Published
10/11/2023 7:37 PM
7808 - Caution : Proper connection of wiring harnesses is critical.
Annotation
Published
07/07/2023 9:39 PM
7809 - Reconnect 4 wiring harness assembly/connectors (J6, J8, J10, J11) from SCA-77...
Instruction
Published
07/07/2023 9:42 PM
7810 - Ensure all pins are engaged. It is easy to install the connectors one pin off...
Remark
Published
07/07/2023 9:44 PM
7836 - 7813 - Reconnect BNC connectors on top of SCA-775 module; Remark:
Procedure Step
Published
07/07/2023 11:42 PM
7811 - Caution : Proper connection of cables is critical.
Annotation
Published
07/07/2023 9:48 PM
7813 - Reconnect BNC connectors on top of SCA-775 module
Instruction
Published
07/07/2023 9:49 PM
7837 - 7814 - Close SCA-775 module cover and tighten 4 screws; Remark:7815
Procedure Step
Published
07/07/2023 11:09 PM
7814 - Close SCA-775 module cover and tighten 4 screws
Instruction
Published
07/07/2023 9:50 PM
7815 - If the follow-on alignment and functional compliance test procedures are to b...
Remark
Published
07/07/2023 9:52 PM
7280 - 7250 - Power on RPM; Remark:7251
Procedure Step
Published
04/27/2023 4:14 PM
7250 - Power on RPM
Instruction
Published
05/01/2023 8:31 AM
7251 - Move LD-260 switch to ON position. The LED PWR ON
Remark
Published
05/10/2023 3:14 PM
7281 - 7252 - Verify RPM start-up; Remark:7253
Procedure Step
Published
04/20/2025 3:26 PM
7252 - Verify RPM start-up
Instruction
Published
04/27/2023 2:23 PM
7253 - RPM will perform a power on self-test (POST) and collect a background radiati...
Remark
Published
05/10/2023 3:14 PM
7279 - 7249 - Return equipment to normal operating condition; Remark:
Procedure Step
Published
04/27/2023 4:13 PM
7249 - Return equipment to normal operating condition
Instruction
Published
04/08/2025 3:22 PM
7840 - 7816 - Perform electronic alignment; Remark:7817
Procedure Step
Published
07/07/2023 11:12 PM
7816 - Perform electronic alignment
Instruction
Published
07/07/2023 9:55 PM
7817 - DET-RPM-RAP-CM01, RPM Electronic Alignment Procedure.
Remark
Published
04/13/2025 5:55 PM
7842 - 7820 - Inform system operators upon completion of maintenance action; Remark:
Procedure Step
Published
07/07/2023 11:15 PM
7820 - Inform system operators upon completion of maintenance action
Instruction
Published
07/07/2023 10:02 PM
322 - 321 - Document maintenance actions; Remark:
Procedure Step
Published
06/17/2021 9:49 AM
321 - Document maintenance actions
Instruction
Published
04/21/2025 11:19 AM
2869 - 2585 - Document maintenance performed; Remark:2866
Procedure Step
Published
06/18/2021 5:58 PM
2585 - Document maintenance performed
Instruction
Published
07/09/2021 12:15 PM
2866 - Record observations, times, and results for the maintenance report.
Remark
Published
04/21/2025 11:39 AM
4706 - 4705 - Submit report; Remark:4864
Procedure Step
Published
06/29/2022 9:50 AM
4705 - Submit report
Instruction
Published
06/29/2022 9:50 AM
4864 - As specified by management or contractual obligations.
Remark
Published
07/28/2022 1:36 PM
Corrective Maintenance Procedure
Document Type
Published
03/02/2020 3:32 PM
Upon SCA-774 board failure
Frequency
Published
07/07/2023 11:22 PM
Warning
Annotation Type
Published
03/02/2020 3:25 PM
Note
Annotation Type
Published
03/02/2020 3:25 PM
Caution
Annotation Type
Published
03/02/2020 3:24 PM
Technician 2
Skill Level
Published
04/09/2020 1:17 AM
Keys to access RPM
Replacement Parts
Published
04/27/2023 6:56 PM
Reflective safety vest if required
Replacement Parts
Published
06/20/2023 4:47 PM
safety glasses
Replacement Parts
Published
07/02/2023 4:48 PM
Ladder; 2 meters, 6 feet tall; non-conducting if required
Replacement Parts
Published
07/02/2023 4:48 PM
Traffic control cones or equivalent if required
Replacement Parts
Published
06/20/2023 4:47 PM
Phillips screwdriver, small
Replacement Parts
Published
07/07/2023 11:39 PM
Phillips screwdriver, medium
Replacement Parts
Published
07/07/2023 11:39 PM
LD-260 Disconnect Switch Power Off
Image
Published
04/24/2023 12:49 PM
Disconnect Signal BNC Cables
Image
Published
07/07/2023 2:20 PM
Remove Six (6) Cover Screws
Image
Published
07/07/2023 2:27 PM
Cover screws are captured
Image
Published
10/04/2023 3:01 PM
To prevent breaking the hinge
Image
Published
10/04/2023 3:02 PM
SCA-774 Screws at Corner
Image
Published
07/07/2023 9:30 PM
LD-260 Disconnect Switch Power On
Image
Published
05/04/2023 3:37 PM

RPM Functional Compliance Test

Last Updated: 05/02/2025 1:43 AM

The following table lists all the components that make up the document.

Title Type Status Last Updated
Rapiscan VM-250 Vehicle Monitor
Device
Published
10/14/2024 9:50 AM
Rapiscan PM-700 Pedestrian Monitor
Device
Published
06/20/2024 11:38 AM
Rapiscan TM-850 Rail Monitor
Device
Published
09/18/2024 10:28 AM
7738 - 7646 - Prepare RPM Specific FCT Datasheet; Remark:
Procedure Step
Published
07/03/2023 10:36 AM
7647 - Note : Step 1 (1 through 1-4) should be performed before traveling to the RPMs. ...
Annotation
Published
06/30/2023 1:12 PM
7646 - Prepare RPM Specific FCT Datasheet
Instruction
Published
06/30/2023 1:11 PM
7739 - 7648 - Open most recent baselined FCT datasheet on laptop; Remark:
Procedure Step
Published
07/02/2023 12:27 PM
7648 - Open most recent baselined FCT datasheet on laptop
Instruction
Published
06/30/2023 1:14 PM
7740 - 7649 - Save file with unique name (add today's date) and close master copy; Remark:7650
Procedure Step
Published
07/02/2023 12:28 PM
7649 - Save file with unique name (add today's date) and close master copy
Instruction
Published
06/30/2023 1:15 PM
7650 - An example of a unique file name is US_PortofEntry_FCT_Lane1_05132016...
Remark
Published
07/02/2023 3:00 AM
7741 - 7651 - Enter date of procedure performance in appropriate cell; Remark:
Procedure Step
Published
07/02/2023 12:30 PM
7652 - Note : Date of procedure in FCT datasheet is extremely important for correct radioac...
Annotation
Published
07/02/2023 5:22 PM
7651 - Enter date of procedure performance in appropriate cell
Instruction
Published
06/30/2023 1:19 PM
7742 - 7653 - Enter RPM identification information; Remark:7654
Procedure Step
Published
07/02/2023 12:32 PM
7653 - Enter RPM identification information
Instruction
Published
06/30/2023 1:21 PM
7654 - Complete the General Information section to specifically identify the RPM (se...
Remark
Published
07/02/2023 3:01 AM
7743 - 7655 - Verify Gamma Radioactive Source is Sufficient for FCT; Remark:
Procedure Step
Published
07/02/2023 12:37 PM
7655 - Verify Gamma Radioactive Source is Sufficient for FCT
Instruction
Published
07/02/2023 5:23 PM
7744 - 7656 - Enter Co-57 source identification number; Remark:7657
Procedure Step
Published
07/02/2023 12:40 PM
7656 - Enter Co-57 source identification number
Instruction
Published
06/30/2023 2:26 PM
7657 - Source information is commonly listed directly on the label of radioactive so...
Remark
Published
07/02/2023 3:01 AM
7745 - 7658 - Enter Co-57 initial activity in kBq (as listed on source label or source cert...; Remark:7659
Procedure Step
Published
07/02/2023 12:40 PM
7658 - Enter Co-57 initial activity in kBq (as listed on source label or source cert...
Instruction
Published
06/30/2023 2:35 PM
7659 - Source Activity Level
Remark
Published
07/02/2023 3:02 AM
7746 - 7660 - Enter Co-57 source calibration date; Remark:7661
Procedure Step
Published
07/02/2023 12:42 PM
7660 - Enter Co-57 source calibration date
Instruction
Published
06/30/2023 2:46 PM
7661 - Source Calibration Date
Remark
Published
07/02/2023 3:02 AM
7747 - 7662 - Verify Co-57 calculated current activity is within specified limits; Remark:7664
Procedure Step
Published
04/13/2025 6:20 PM
7663 - Standard : Current Co-57 source activity must be between 19 and 400 kBq to perform this ...
Annotation
Published
07/02/2023 5:24 PM
7662 - Verify Co-57 calculated current activity is within specified limits
Instruction
Published
04/13/2025 5:49 PM
7664 - Source Current Activity Level
Remark
Published
07/02/2023 3:03 AM
7748 - 7665 - Verify Neutron Radioactive Source is Sufficient for FCT ...; Remark:
Procedure Step
Published
07/02/2023 12:46 PM
7665 - Verify Neutron Radioactive Source is Sufficient for FCT ...
Instruction
Published
06/30/2023 2:59 PM
7749 - 7666 - Enter Cf-252 source identification number; Remark:7667
Procedure Step
Published
07/02/2023 12:48 PM
7666 - Enter Cf-252 source identification number
Instruction
Published
06/30/2023 3:00 PM
7667 - Source information is commonly listed directly on the label of the radioactiv...
Remark
Published
07/03/2023 10:21 AM
7750 - 7668 - Enter Cf-252 source activity in kBq (as listed on source label or source cert...; Remark:7669
Procedure Step
Published
07/02/2023 12:49 PM
7668 - Enter Cf-252 source activity in kBq (as listed on source label or source cert...
Instruction
Published
06/30/2023 3:23 PM
7669 -
Remark
Published
07/02/2023 12:51 PM
7751 - 7670 - Enter Cf-252 source calibration date; Remark:7671
Procedure Step
Published
07/02/2023 12:52 PM
7670 - Enter Cf-252 source calibration date
Instruction
Published
06/30/2023 3:35 PM
7671 - Certificate of Calibration Neutron Date
Remark
Published
07/02/2023 3:04 AM
7752 - 7673 - Verify Cf-252 calculated current activity is within specified limits; Remark:7674
Procedure Step
Published
07/02/2023 12:54 PM
7672 - Standard : Current Cf-252 source activity must be between 37 and 185 kBq to perform this...
Annotation
Published
06/30/2023 3:42 PM
7673 - Verify Cf-252 calculated current activity is within specified limits
Instruction
Published
06/30/2023 3:44 PM
7674 - Current Cf-252 source activity must be between 2,000 and 20,000 n/s to perfor...
Remark
Published
07/02/2023 3:05 AM
7621 - 1401 - Establish Initial Conditions; Remark:
Procedure Step
Published
06/29/2023 5:37 PM
1401 - Establish Initial Conditions
Instruction
Published
09/30/2022 3:14 PM
7622 - 7592 - Inform system operators; Remark:11335
Procedure Step
Published
04/20/2025 10:15 AM
7592 - Inform system operators
Instruction
Published
06/29/2023 3:20 PM
11335 - Upon arrival, brief system operators on expected work, duration, anticipated ...
Remark
Published
04/20/2025 10:14 AM
7753 - 7676 - Brief system operators on expected work, duration, anticipated alarms, and fa...; Remark:7677
Procedure Step
Published
07/02/2023 1:53 PM
7676 - Brief system operators on expected work, duration, anticipated alarms, and fa...
Instruction
Published
07/01/2023 11:39 PM
7677 - Operators should expect numerous fault indications and alarms during procedur...
Remark
Published
07/02/2023 3:05 AM
7754 - 7594 - Close lane and set up barriers to establish a safety watch; Remark:7595
Procedure Step
Published
07/02/2023 1:55 PM
7678 - Warning : Traffic should temporarily be rerouted or halted during conduction of this pr...
Annotation
Published
07/03/2023 10:23 AM
7594 - Close lane and set up barriers to establish a safety watch
Instruction
Published
06/29/2023 3:28 PM
7595 - Use orange safety (traffic control) cones or equivalent per site-specific saf...
Remark
Published
06/29/2023 3:33 PM
7755 - 7679 - Disconnect Ethernet; Remark:11336
Procedure Step
Published
04/20/2025 11:18 AM
7680 - Caution : Make sure to press release button on back of Ethernet cable before removing.
Annotation
Published
07/01/2023 11:54 PM
7679 - Disconnect Ethernet
Instruction
Published
07/01/2023 11:52 PM
11336 - Locate Ethernet connector on top of SC-770 controller. Press release button o...
Remark
Published
04/20/2025 11:21 AM
7756 - 7681 - Disable occupancy sensor; Remark:7682
Procedure Step
Published
07/02/2023 1:59 PM
7681 - Disable occupancy sensor
Instruction
Published
07/01/2023 11:55 PM
7682 - For vehicle monitor, disconnect both break-beam sensor receivers (usually*) l...
Remark
Published
07/02/2023 3:06 AM
7757 - 344 - Verify parameter settings are correct; Remark:
Procedure Step
Published
07/02/2023 2:00 PM
344 - Verify parameter settings are correct
Instruction
Published
07/03/2023 10:24 AM
7280 - 7250 - Power on RPM; Remark:7251
Procedure Step
Published
04/27/2023 4:14 PM
7250 - Power on RPM
Instruction
Published
05/01/2023 8:31 AM
7251 - Move LD-260 switch to ON position. The LED PWR ON
Remark
Published
05/10/2023 3:14 PM
7281 - 7252 - Verify RPM start-up; Remark:7253
Procedure Step
Published
04/20/2025 3:26 PM
7252 - Verify RPM start-up
Instruction
Published
04/27/2023 2:23 PM
7253 - RPM will perform a power on self-test (POST) and collect a background radiati...
Remark
Published
05/10/2023 3:14 PM
7760 - 7683 - Record SC-770 parameter values; Remark:7684
Procedure Step
Published
07/02/2023 2:09 PM
7685 - Caution : Each SC-770 parameter must match the values obtained from the LANL configurat...
Annotation
Published
07/02/2023 12:20 AM
7683 - Record SC-770 parameter values
Instruction
Published
07/02/2023 12:09 AM
7684 - Enter Program Mode by pressing "0." Enter the password 1234...
Remark
Published
07/02/2023 3:06 AM
7761 - 7686 - Manually enter variable values; Remark:7687
Procedure Step
Published
07/02/2023 2:12 PM
7686 - Manually enter variable values
Instruction
Published
07/02/2023 12:22 AM
7687 - Variable values include parameters such as N*Sigma and Alpha value.
Remark
Published
04/13/2025 5:49 PM
7762 - 7688 - Click the check box to confirm fixed values; Remark:
Procedure Step
Published
04/13/2025 6:20 PM
7688 - Click the check box to confirm fixed values
Instruction
Published
04/13/2025 5:49 PM
7763 - 7689 - Return to SC-770 main menu; Remark:7690
Procedure Step
Published
07/02/2023 2:14 PM
7689 - Return to SC-770 main menu
Instruction
Published
07/02/2023 12:28 AM
7690 - Press "#" button until the SC-770 displays the main menu.
Remark
Published
04/13/2025 5:50 PM
7764 - 7691 - Perform Gamma Detector Efficiency Measurements; Remark:
Procedure Step
Published
04/13/2025 6:20 PM
7691 - Perform Gamma Detector Efficiency Measurements
Instruction
Published
04/13/2025 5:50 PM
7765 - 7694 - Navigate SC-770 to SHOW COUNTS for gamma detectors; Remark:7695
Procedure Step
Published
07/02/2023 2:18 PM
7692 - Caution : Keep gamma detectors protected from direct sunlight.
Annotation
Published
04/13/2025 5:50 PM
7693 - Note : Verify there are no radiation sources sources within 20 meters of the RPM whi...
Annotation
Published
07/02/2023 12:40 AM
7694 - Navigate SC-770 to SHOW COUNTS for gamma detectors
Instruction
Published
07/02/2023 12:41 AM
7695 - From SC-770 main programming menu, press GAMMA
Remark
Published
04/13/2025 5:52 PM
7766 - 7696 - Record measured gamma background count rate for each gamma detector; Remark:7697
Procedure Step
Published
07/02/2023 2:19 PM
7696 - Record measured gamma background count rate for each gamma detector
Instruction
Published
07/02/2023 12:57 AM
7697 - Stand clear of all gamma detectors, watch displayed count rate for each chann...
Remark
Published
07/02/2023 3:07 AM
7767 - 7700 - Place label side of Co-57 gamma source against yellow dot at center of detect...; Remark:7701
Procedure Step
Published
07/02/2023 2:23 PM
7698 - Standard : Due to low energy of Co-57 gammas, the count rate on either side of the sourc...
Annotation
Published
07/02/2023 1:07 AM
7699 - Note : Verify distance between source and detector is minimized to warrant accurate ...
Annotation
Published
07/02/2023 1:08 AM
7700 - Place label side of Co-57 gamma source against yellow dot at center of detect...
Instruction
Published
07/02/2023 1:09 AM
7701 - The source must be held firmly against the detector with a low-density tool s...
Remark
Published
07/02/2023 3:08 AM
7768 - 7702 - Record gamma count rate in appropriate "Source Count Rate (Co-57)" cell; Remark:7704
Procedure Step
Published
07/02/2023 2:25 PM
7703 - Note : Verify that there are no additional radiation sources within 20 meters of the...
Annotation
Published
07/02/2023 1:17 AM
7702 - Record gamma count rate in appropriate "Source Count Rate (Co-57)" cell
Instruction
Published
07/02/2023 1:15 AM
7704 - Stand clear of all gamma detectors, watch displayed count rate for each chann...
Remark
Published
07/02/2023 1:23 AM
7769 - 7705 - Repeat for each gamma detector in RPM; Remark:
Procedure Step
Published
07/02/2023 2:27 PM
7705 - Repeat for each gamma detector in RPM
Instruction
Published
07/02/2023 1:25 AM
7770 - 7707 - Verify gamma detector efficiency; Remark:7708
Procedure Step
Published
04/13/2025 6:20 PM
7706 - Standard : Gamma detector efficiency should be greater than 20%
Annotation
Published
07/02/2023 1:31 AM
7707 - Verify gamma detector efficiency
Instruction
Published
04/13/2025 5:52 PM
7708 - Gamma Detector Efficiency
Remark
Published
07/02/2023 3:08 AM
7771 - 7709 - Go to SC-770 main menu; Remark:7710
Procedure Step
Published
07/02/2023 2:31 PM
7709 - Go to SC-770 main menu
Instruction
Published
07/02/2023 1:41 AM
7710 - Press "#" button until the SC-770 displays the main menu.
Remark
Published
07/02/2023 3:09 AM
7772 - 7711 - Perform Neutron Detector Efficiency Measurements; Remark:
Procedure Step
Published
07/02/2023 2:33 PM
7711 - Perform Neutron Detector Efficiency Measurements
Instruction
Published
07/02/2023 1:49 AM
7773 - 7712 - Enter "fixed" neutron background count rate for each neutron detector; Remark:7713
Procedure Step
Published
07/02/2023 2:34 PM
7712 - Enter "fixed" neutron background count rate for each neutron detector
Instruction
Published
07/02/2023 1:52 AM
7713 - Record 1 counts per second (cps) for each neutron tube installed on each chan...
Remark
Published
07/02/2023 2:00 AM
7774 - 7714 - Navigate SC-770 to SHOW COUNTS for neutron detectors; Remark:7715
Procedure Step
Published
07/02/2023 2:36 PM
7714 - Navigate SC-770 to SHOW COUNTS for neutron detectors
Instruction
Published
07/02/2023 2:02 AM
7715 - From SC-770 main programming menu, press NEUTRON ...
Remark
Published
04/13/2025 6:19 PM
7775 - 7718 - Place Cf-252 neutron source against yellow dot on center of detector; Remark:7719
Procedure Step
Published
07/02/2023 2:37 PM
7716 - Warning : Do not hold the neutron source on the detector face with your hand or stand n...
Annotation
Published
07/02/2023 2:07 AM
7717 - Note : During the neutron detector efficiency tests, verify no one is near t...
Annotation
Published
07/02/2023 2:10 AM
7718 - Place Cf-252 neutron source against yellow dot on center of detector
Instruction
Published
07/02/2023 2:12 AM
7719 - It is acceptable to use adhesive tape for this step
Remark
Published
04/13/2025 5:54 PM
7776 - 7720 - Record neutron count rate in appropriate "Source Count Rate (Cf-252)" cell; Remark:7722
Procedure Step
Published
07/02/2023 2:38 PM
7721 - Note : Ensure that threre are no additional radiation sources within 20 meters of th...
Annotation
Published
07/02/2023 2:18 AM
7720 - Record neutron count rate in appropriate "Source Count Rate (Cf-252)" cell
Instruction
Published
07/02/2023 2:15 AM
7722 - Stand clear of all neutron detectors, watch displayed count rate for each cha...
Remark
Published
07/02/2023 2:22 AM
7777 - 7723 - Repeat for all neutron detectors in RPM; Remark:
Procedure Step
Published
07/02/2023 2:40 PM
7723 - Repeat for all neutron detectors in RPM
Instruction
Published
07/02/2023 2:24 AM
7778 - 7724 - Verify neutron detector efficiency; Remark:7726
Procedure Step
Published
07/02/2023 2:42 PM
7725 - Standard : Neutron detector efficiency should be greater than 5% (VM with 2 helium tubes...
Annotation
Published
07/02/2023 2:27 AM
7724 - Verify neutron detector efficiency
Instruction
Published
07/02/2023 2:25 AM
7726 - Neutron Source Efficiency
Remark
Published
07/02/2023 2:29 AM
7279 - 7249 - Return equipment to normal operating condition; Remark:
Procedure Step
Published
04/27/2023 4:13 PM
7249 - Return equipment to normal operating condition
Instruction
Published
04/08/2025 3:22 PM
7780 - 7728 - Exit SC-770 programming mode; Remark:7729
Procedure Step
Published
07/02/2023 2:44 PM
7728 - Exit SC-770 programming mode
Instruction
Published
07/02/2023 2:33 AM
7729 - Press "#" until SC-770 exits programming mode and return to normal operating ...
Remark
Published
07/02/2023 2:34 AM
7781 - 7730 - Reconnect Ethernet; Remark:7731
Procedure Step
Published
04/20/2025 11:00 AM
7730 - Reconnect Ethernet
Instruction
Published
07/02/2023 2:34 AM
7731 - Insert Ethernet connector at top of SC-770 module. Connector will audibly "cl...
Remark
Published
07/02/2023 2:36 AM
7782 - 319 - Perform operational test; Remark:7734
Procedure Step
Published
07/02/2023 2:47 PM
7732 - Caution : It is critical that the RPM be returned to the proper operational configurati...
Annotation
Published
07/02/2023 2:39 AM
319 - Perform operational test
Instruction
Published
06/10/2021 8:31 PM
7734 - Perform procedure DET-RPM-RAP‐RM03 RPM Operational Testing.
Remark
Published
07/02/2023 2:43 AM
7842 - 7820 - Inform system operators upon completion of maintenance action; Remark:
Procedure Step
Published
07/07/2023 11:15 PM
7820 - Inform system operators upon completion of maintenance action
Instruction
Published
07/07/2023 10:02 PM
322 - 321 - Document maintenance actions; Remark:
Procedure Step
Published
06/17/2021 9:49 AM
321 - Document maintenance actions
Instruction
Published
04/21/2025 11:19 AM
2869 - 2585 - Document maintenance performed; Remark:2866
Procedure Step
Published
06/18/2021 5:58 PM
2585 - Document maintenance performed
Instruction
Published
07/09/2021 12:15 PM
2866 - Record observations, times, and results for the maintenance report.
Remark
Published
04/21/2025 11:39 AM
4706 - 4705 - Submit report; Remark:4864
Procedure Step
Published
06/29/2022 9:50 AM
4705 - Submit report
Instruction
Published
06/29/2022 9:50 AM
4864 - As specified by management or contractual obligations.
Remark
Published
07/28/2022 1:36 PM
Routine Maintenance Procedure
Document Type
Published
03/02/2020 3:31 PM
Annually
Frequency
Published
04/01/2020 11:37 AM
As specified by corrective maintenance retest requirements following guidance from the Nuclear Smuggling Detection and Deterrence (NSDD) Program
Frequency
Published
07/02/2023 3:28 PM
Note
Annotation Type
Published
03/02/2020 3:25 PM
Standard
Annotation Type
Published
03/02/2020 3:25 PM
Warning
Annotation Type
Published
03/02/2020 3:25 PM
Caution
Annotation Type
Published
03/02/2020 3:24 PM
Technician 1
Skill Level
Published
05/14/2020 2:56 PM
Technician 2
Skill Level
Published
04/09/2020 1:17 AM
Keys to access RPM
Replacement Parts
Published
04/27/2023 6:56 PM
Reflective safety vest if required
Replacement Parts
Published
06/20/2023 4:47 PM
safety glasses
Replacement Parts
Published
07/02/2023 4:48 PM
Ladder; 2 meters, 6 feet tall; non-conducting if required
Replacement Parts
Published
07/02/2023 4:48 PM
Traffic control cones or equivalent if required
Replacement Parts
Published
06/20/2023 4:47 PM
Source-holding device ~ 1.5 m long extending rod or pole
Replacement Parts
Published
07/02/2023 4:48 PM
Flashlight/headlight is recommended
Replacement Parts
Published
07/02/2023 4:48 PM
Laptop computer with current baselined functional compliance test, FCT, datasheet
Replacement Parts
Published
07/02/2023 4:48 PM
Functional Compliance Testting Data
Image
Published
06/30/2023 1:26 PM
Source Activity Label
Image
Published
06/30/2023 2:37 PM
Certificate of Calibration Source Activity
Image
Published
06/30/2023 2:38 PM
Source Calibration Date
Image
Published
06/30/2023 2:43 PM
Certificate of Calibration Source Date
Image
Published
06/30/2023 2:44 PM
Certificate of Calibration Current Source Activity
Image
Published
06/30/2023 2:51 PM
Certificate of Calibration Current Neutron Date
Image
Published
06/30/2023 3:37 PM
Certificate of Calibration Current Neutron Current Level
Image
Published
06/30/2023 3:45 PM
Disconnect Ethernet cable on top of SC-770 box
Image
Published
10/04/2023 2:59 PM
LD-260 Disconnect Switch Power On
Image
Published
05/04/2023 3:37 PM
SC-770 Main Menu
Image
Published
07/02/2023 12:29 AM
Record Measured Gamma Background
Image
Published
07/02/2023 12:56 AM
Gamma Count in Co-57 Source
Image
Published
07/02/2023 1:20 AM
Gamma Detector Efficiency
Image
Published
07/02/2023 1:39 AM
Neutron Background Count Rate
Image
Published
07/02/2023 1:54 AM
Neutron Count Rate
Image
Published
07/02/2023 2:21 AM
Neutron Source Efficiency
Image
Published
07/02/2023 2:28 AM
Functional Compliance Test Results
Image
Published
07/02/2023 2:43 AM

RPM IXIO-DT1 Occupancy Sensor Replacement

Last Updated: 05/02/2025 1:43 AM

The following table lists all the components that make up the document.

Title Type Status Last Updated
Rapiscan PM-700 Pedestrian Monitor
Device
Published
06/20/2024 11:38 AM
7478 - 1401 - Establish Initial Conditions; Remark:
Procedure Step
Published
09/01/2023 7:48 PM
1401 - Establish Initial Conditions
Instruction
Published
09/30/2022 3:14 PM
7452 - 7231 - Close lane; Remark:7415
Procedure Step
Published
06/02/2023 5:12 PM
7231 - Close lane
Instruction
Published
04/18/2023 1:00 PM
7415 - Re-route pedestrian traffic.
Remark
Published
06/02/2023 1:08 PM
7453 - 7232 - Open RPM door; Remark:7267
Procedure Step
Published
06/02/2023 5:24 PM
7232 - Open RPM door
Instruction
Published
04/18/2023 1:02 PM
7267 - Open all doors needed to access components.
Remark
Published
09/16/2023 4:54 PM
7454 - 7290 - Disable tamper switches; Remark:7416
Procedure Step
Published
06/02/2023 5:25 PM
7290 - Disable tamper switches
Instruction
Published
05/01/2023 8:14 AM
7416 - Use a magnet to disable tamper switches for all open doors. Use adhesive tape...
Remark
Published
06/02/2023 1:18 PM
7270 - 7235 - Power off RPM; Remark:7236
Procedure Step
Published
09/01/2023 7:57 PM
7235 - Power off RPM
Instruction
Published
04/24/2023 12:30 PM
7236 - Move LD-260 switch to OFF position. The PWR ON
Remark
Published
04/27/2023 4:25 PM
7479 - 7417 - Prepare New Occupancy Sensor; Remark:
Procedure Step
Published
06/02/2023 6:13 PM
7417 - Prepare New Occupancy Sensor
Instruction
Published
06/02/2023 1:39 PM
7456 - 7418 - Remove cover from new occupancy sensor; Remark:7419
Procedure Step
Published
06/02/2023 5:27 PM
7418 - Remove cover from new occupancy sensor
Instruction
Published
06/02/2023 1:43 PM
7419 - Use a slotted screwdriver to pry the cover off from the side.
Remark
Published
04/13/2025 5:44 PM
7457 - 7420 - Verify narrow field radar antenna is installed; Remark:7421
Procedure Step
Published
04/13/2025 6:18 PM
7420 - Verify narrow field radar antenna is installed
Instruction
Published
04/13/2025 5:44 PM
7421 - The IXIO-DT1 should come with the narrow field antenna installed.
Remark
Published
06/02/2023 2:14 PM
8901 - If needed, the antenna can be changed. Remove cover. Install narrow field ant...
Remark
Published
09/25/2023 9:51 PM
7480 - 7422 - Uninstall Faulty Occupancy Sensor; Remark:
Procedure Step
Published
06/02/2023 9:42 PM
7422 - Uninstall Faulty Occupancy Sensor
Instruction
Published
06/02/2023 2:16 PM
7458 - 7423 - Remove Cover; Remark:7424
Procedure Step
Published
06/02/2023 5:28 PM
7423 - Remove Cover
Instruction
Published
06/02/2023 2:18 PM
7424 - If needed, use a sharp utility knife to cut sealant around edges of sensor. A...
Remark
Published
06/02/2023 2:21 PM
7459 - 7425 - Disconnect wire connector; Remark:7426
Procedure Step
Published
06/02/2023 5:29 PM
7425 - Disconnect wire connector
Instruction
Published
06/02/2023 2:48 PM
7426 - The wire connector is located on the right side of existing sensor.
Remark
Published
06/02/2023 2:53 PM
7460 - 7427 - Loosen two (2) mounting screws; Remark:7428
Procedure Step
Published
06/02/2023 5:30 PM
7429 - Note : Some existing occupancy sensors are installed using screws and nuts, ...
Annotation
Published
06/02/2023 3:09 PM
7427 - Loosen two (2) mounting screws
Instruction
Published
06/02/2023 2:56 PM
7428 - Use a medium Phillips (PH2) screwdriver. If screws and nuts were used, an adj...
Remark
Published
06/02/2023 3:04 PM
7461 - 7430 - Remove faulty occupancy sensor; Remark:7431
Procedure Step
Published
06/02/2023 5:31 PM
7430 - Remove faulty occupancy sensor
Instruction
Published
06/02/2023 3:11 PM
7431 - If a Wizard G3 sensor is being removed, push up on both sides to free the sen...
Remark
Published
09/29/2023 1:49 PM
3397 - 3395 - Label faulty component; Remark:3396
Procedure Step
Published
07/21/2024 6:59 AM
3395 - Label faulty component
Instruction
Published
08/07/2021 11:07 AM
3396 - Use tag or tape. Include date of removal, description of failure symptoms, co...
Remark
Published
08/09/2021 11:35 AM
7481 - 7432 - Install new occupancy sensor; Remark:
Procedure Step
Published
06/02/2023 9:46 PM
7432 - Install new occupancy sensor
Instruction
Published
06/02/2023 3:27 PM
7463 - 7433 - Mount new sensor; Remark:7434
Procedure Step
Published
06/02/2023 5:32 PM
7433 - Mount new sensor
Instruction
Published
06/02/2023 3:29 PM
7434 - First, slide left side onto mounting screw.
Remark
Published
04/13/2025 5:44 PM
9206 - Then, place right side over mounting screw and push down.
Remark
Published
09/29/2023 1:55 PM
7464 - 7435 - Tighten two (2) mounting screws; Remark:7436
Procedure Step
Published
06/02/2023 5:33 PM
7435 - Tighten two (2) mounting screws
Instruction
Published
06/02/2023 3:40 PM
7436 - Use medium Phillips (PH2) screwdriver. Take care not to overtighten.
Remark
Published
04/13/2025 5:45 PM
7482 - 7437 - Route wiring through clamp and connect; Remark:7488
Procedure Step
Published
06/02/2023 10:42 PM
7437 - Route wiring through clamp and connect
Instruction
Published
06/02/2023 3:53 PM
7488 - Clamp and Connect
Remark
Published
06/02/2023 10:49 PM
7465 - 7439 - Adjust angle of the radar antenna; Remark:7438
Procedure Step
Published
04/13/2025 6:19 PM
7439 - Adjust angle of the radar antenna
Instruction
Published
04/13/2025 5:45 PM
7438 - The angle is adjusted by manually rotating the antenna up or down. The defaul...
Remark
Published
09/29/2023 1:58 PM
7279 - 7249 - Return equipment to normal operating condition; Remark:
Procedure Step
Published
04/27/2023 4:13 PM
7249 - Return equipment to normal operating condition
Instruction
Published
04/08/2025 3:22 PM
7466 - 7440 - Hold door open; Remark:7441
Procedure Step
Published
06/02/2023 5:35 PM
7440 - Hold door open
Instruction
Published
06/02/2023 4:10 PM
7441 - Do not move door. Door must remain stationary to prevent occupancy.
Remark
Published
04/13/2025 5:45 PM
7280 - 7250 - Power on RPM; Remark:7251
Procedure Step
Published
04/27/2023 4:14 PM
7250 - Power on RPM
Instruction
Published
05/01/2023 8:31 AM
7251 - Move LD-260 switch to ON position. The LED PWR ON
Remark
Published
05/10/2023 3:14 PM
7468 - 7304 - Confirm RPM has restarted correctly; Remark:7487
Procedure Step
Published
06/02/2023 5:36 PM
7304 - Confirm RPM has restarted correctly
Instruction
Published
05/01/2023 8:31 AM
7487 - The SC-770 controller will display "OK" following Power On Self-Test (POST) a...
Remark
Published
06/02/2023 10:35 PM
7282 - 7254 - Confirm network connection; Remark:7255
Procedure Step
Published
04/27/2023 4:15 PM
7254 - Confirm network connection
Instruction
Published
04/27/2023 2:22 PM
7255 - Contact operators to confirm communications have been reestablished between RPM ...
Remark
Published
05/10/2023 3:15 PM
7470 - 7442 - Generate occupancy; Remark:7443
Procedure Step
Published
06/02/2023 5:37 PM
7442 - Generate occupancy
Instruction
Published
06/02/2023 4:19 PM
7443 - Create motion in front of occupancy sensor. While holding the door open and s...
Remark
Published
06/02/2023 4:21 PM
7471 - 7444 - Verify occupancy sensor functionality; Remark:7445
Procedure Step
Published
06/02/2023 5:38 PM
7444 - Verify occupancy sensor functionality
Instruction
Published
06/02/2023 4:32 PM
7445 - IXIO-DT1 green sensor light will illuminate.
Remark
Published
06/02/2023 4:35 PM
8973 - Left latch on the LCD screen will indicate a “closed” circuit.
Remark
Published
09/25/2023 11:05 PM
8974 - SC-770 status will read “OCCUPIED”.
Remark
Published
09/25/2023 11:06 PM
7472 - 7446 - Install sensor cover; Remark:7447
Procedure Step
Published
06/02/2023 5:38 PM
7446 - Install sensor cover
Instruction
Published
06/02/2023 4:37 PM
7447 - The cover should snap into place.
Remark
Published
06/02/2023 4:38 PM
7473 - 7448 - If needed, apply sealant; Remark:7449
Procedure Step
Published
06/02/2023 5:39 PM
7448 - If needed, apply sealant
Instruction
Published
06/02/2023 4:39 PM
7449 - If used outdoors, sealant should be applied to top and sides of cover. Do not...
Remark
Published
06/02/2023 4:41 PM
7474 - 7310 - Enable tamper switches; Remark:7451
Procedure Step
Published
06/02/2023 5:41 PM
7310 - Enable tamper switches
Instruction
Published
05/01/2023 8:36 AM
7451 - Remove magnets and/or adhesive tape from door tamper switches.
Remark
Published
04/13/2025 5:46 PM
7283 - 7256 - Close and lock all RPM doors; Remark:
Procedure Step
Published
09/01/2023 11:45 PM
7256 - Close and lock all RPM doors
Instruction
Published
04/27/2023 2:21 PM
7842 - 7820 - Inform system operators upon completion of maintenance action; Remark:
Procedure Step
Published
07/07/2023 11:15 PM
7820 - Inform system operators upon completion of maintenance action
Instruction
Published
07/07/2023 10:02 PM
322 - 321 - Document maintenance actions; Remark:
Procedure Step
Published
06/17/2021 9:49 AM
321 - Document maintenance actions
Instruction
Published
04/21/2025 11:19 AM
2869 - 2585 - Document maintenance performed; Remark:2866
Procedure Step
Published
06/18/2021 5:58 PM
2585 - Document maintenance performed
Instruction
Published
07/09/2021 12:15 PM
2866 - Record observations, times, and results for the maintenance report.
Remark
Published
04/21/2025 11:39 AM
4706 - 4705 - Submit report; Remark:4864
Procedure Step
Published
06/29/2022 9:50 AM
4705 - Submit report
Instruction
Published
06/29/2022 9:50 AM
4864 - As specified by management or contractual obligations.
Remark
Published
07/28/2022 1:36 PM
Corrective Maintenance Procedure
Document Type
Published
03/02/2020 3:32 PM
Instrument is not functioning correctly
Frequency
Published
12/19/2022 5:52 PM
Note
Annotation Type
Published
03/02/2020 3:25 PM
Technician 1
Skill Level
Published
05/14/2020 2:56 PM
Keys to access RPM
Replacement Parts
Published
04/27/2023 6:56 PM
Magnets and adhesive tape to disable door tamper switches
Replacement Parts
Published
06/02/2023 10:08 PM
Medium slotted screwdriver
Replacement Parts
Published
06/02/2023 10:08 PM
Medium Phillips (PH2) screwdriver
Tools
Published
04/24/2020 4:40 PM
Adjustable wrench
Replacement Parts
Published
06/02/2023 10:08 PM
Utility knife
Tools
Published
05/19/2020 1:54 PM
Orange/yellow safety vest
Replacement Parts
Published
04/27/2023 6:56 PM
Safety shoes
Replacement Parts
Published
04/27/2023 6:56 PM
Gloves
Replacement Parts
Published
05/10/2023 3:28 PM
Protective headwear: glasses, hard hat
Replacement Parts
Published
05/10/2023 3:31 PM
Orange traffic cones
Replacement Parts
Published
04/27/2023 6:56 PM
Disable tamper switch
Image
Published
09/07/2023 8:22 PM
Disable Tamper Switch
Image
Published
06/02/2023 2:28 PM
LD-260 Disconnect Switch Power Off
Image
Published
04/24/2023 12:49 PM
Remove Occupancy Sensor Cover
Image
Published
06/02/2023 2:38 PM
The IXIO-DT1 should come with the narrow field antenna installed
Image
Published
09/25/2023 8:35 PM
Verify narrow field radar antenna is installed
Image
Published
09/25/2023 8:38 PM
Verify narrow field radar antenna is installed 2
Image
Published
09/25/2023 8:39 PM
Uninstall Occupancy Sensor Cover
Image
Published
06/02/2023 2:37 PM
Disconnect Wire Connector
Image
Published
06/02/2023 2:53 PM
Loosen Two Mounting screws
Image
Published
06/02/2023 3:04 PM
Remove faulty Occupancy Sensor
Image
Published
09/29/2023 1:47 PM
Push Occupancy Sensor to the right
Image
Published
09/29/2023 1:48 PM
Mount new sensor
Image
Published
09/25/2023 8:52 PM
Push Down Over Mounting Screw to Install Occupancy Sensor
Image
Published
06/02/2023 3:51 PM
Tighten Occupancy Sensor Mounting Screws
Image
Published
06/02/2023 3:48 PM
Route wiring through clamp and connect
Image
Published
06/02/2023 3:55 PM
Adjust angle of the radar antenna
Image
Published
09/25/2023 8:56 PM
Adjust angle of the radar antenna2
Image
Published
09/25/2023 8:58 PM
LD-260 Disconnect Switch Power On
Image
Published
05/04/2023 3:37 PM
IXIO-DT1 green sensor light will illuminate
Image
Published
09/25/2023 9:37 PM
Verify occupancy sensor functionality
Image
Published
09/25/2023 9:38 PM
Verify occupancy sensor functionality2
Image
Published
09/25/2023 9:39 PM
Install Occupancy Sensor Cover
Image
Published
06/02/2023 4:26 PM
Occupancy Sensor Sealant Application
Image
Published
06/02/2023 4:30 PM
Remove Magnet from Tamper.PNG
Image
Published
09/28/2023 9:37 AM
Remove Magnet on Tamper Switch
Image
Published
06/02/2023 4:31 PM

RPM Ethernet-to-Fiber Media Converter Replacement

Last Updated: 05/02/2025 1:43 AM

The following table lists all the components that make up the document.

Title Type Status Last Updated
Rapiscan PM-700 Pedestrian Monitor
Device
Published
06/20/2024 11:38 AM
Rapiscan VM-250 Vehicle Monitor
Device
Published
10/14/2024 9:50 AM
Rapiscan TM-850 Rail Monitor
Device
Published
09/18/2024 10:28 AM
7371 - 1401 - Establish Initial Conditions; Remark:
Procedure Step
Published
05/04/2023 4:11 PM
1401 - Establish Initial Conditions
Instruction
Published
09/30/2022 3:14 PM
7372 - 7231 - Close lane; Remark:7233
Procedure Step
Published
09/01/2023 7:52 PM
7261 - Warning : Traffic should temporarily be rerouted or halted during this procedure to ens...
Annotation
Published
09/28/2023 2:09 PM
7231 - Close lane
Instruction
Published
04/18/2023 1:00 PM
7233 - Use orange safety (traffic control) cones to setup barriers. Practice establi...
Remark
Published
04/24/2023 12:18 PM
7373 - 7232 - Open RPM door; Remark:7267
Procedure Step
Published
09/01/2023 7:55 PM
7232 - Open RPM door
Instruction
Published
04/18/2023 1:02 PM
7267 - Open all doors needed to access components.
Remark
Published
09/16/2023 4:54 PM
7374 - 7235 - Power off RPM; Remark:7236
Procedure Step
Published
05/04/2023 4:15 PM
7235 - Power off RPM
Instruction
Published
04/24/2023 12:30 PM
7236 - Move LD-260 switch to OFF position. The PWR ON
Remark
Published
04/27/2023 4:25 PM
7375 - 7356 - Uninstall Faulty Media Converter; Remark:
Procedure Step
Published
05/04/2023 4:17 PM
7356 - Uninstall Faulty Media Converter
Instruction
Published
05/11/2023 12:29 PM
7376 - 7357 - Disconnect Ethernet and optical cables; Remark:7358
Procedure Step
Published
05/04/2023 4:19 PM
5291 - Note : It is good practice to verify all cables and connectors are labeled prior to ...
Annotation
Published
10/24/2022 8:35 AM
7357 - Disconnect Ethernet and optical cables
Instruction
Published
05/11/2023 12:30 PM
7358 - Magnum CS14P Premium Rated Converter Switch
Remark
Published
05/04/2023 1:42 PM
7377 - 7295 - Disconnect power wires; Remark:7359
Procedure Step
Published
05/04/2023 4:20 PM
7295 - Disconnect power wires
Instruction
Published
05/01/2023 8:20 AM
7359 - Use a small precision screwdriver to loosen the screw
Remark
Published
05/11/2023 12:34 PM
7378 - 5405 - Remove two (2) mounting screws; Remark:7360
Procedure Step
Published
05/04/2023 4:21 PM
5405 - Remove two (2) mounting screws
Instruction
Published
10/27/2022 3:28 PM
7360 - Use medium Phillips head (PH2) screwdriver. Retain screws.
Remark
Published
05/11/2023 12:35 PM
7379 - 7361 - Remove faulty media converter; Remark:
Procedure Step
Published
05/04/2023 4:23 PM
7361 - Remove faulty media converter
Instruction
Published
05/11/2023 12:36 PM
3397 - 3395 - Label faulty component; Remark:3396
Procedure Step
Published
07/21/2024 6:59 AM
3395 - Label faulty component
Instruction
Published
08/07/2021 11:07 AM
3396 - Use tag or tape. Include date of removal, description of failure symptoms, co...
Remark
Published
08/09/2021 11:35 AM
7381 - 7362 - Install New Ethernet-to-Fiber Media Converter; Remark:
Procedure Step
Published
05/04/2023 4:25 PM
7362 - Install New Ethernet-to-Fiber Media Converter
Instruction
Published
05/11/2023 12:38 PM
7382 - 7363 - Mount new media converter with two (2) screws; Remark:7396
Procedure Step
Published
05/04/2023 4:53 PM
7363 - Mount new media converter with two (2) screws
Instruction
Published
05/11/2023 12:38 PM
7396 - Use retained screws. Use medium Phillips (PH2) screwdriver.
Remark
Published
05/10/2023 9:11 AM
7397 -
Remark
Published
05/04/2023 4:53 PM
7383 - 7301 - Reconnect power wires; Remark:7364
Procedure Step
Published
05/04/2023 4:27 PM
462 - Caution : Correct placement of connectors and wiring is critical to proper operation.
Annotation
Published
09/28/2023 2:13 PM
7301 - Reconnect power wires
Instruction
Published
05/01/2023 8:26 AM
7364 - Insert power wires and use a small precision screwdriver to tighten the screw.
Remark
Published
05/11/2023 12:39 PM
7384 - 7365 - Reconnect Ethernet and fiber cables; Remark:7366
Procedure Step
Published
05/04/2023 4:28 PM
7365 - Reconnect Ethernet and fiber cables
Instruction
Published
05/11/2023 12:40 PM
7366 - Media Converter Connectors
Remark
Published
05/11/2023 12:40 PM
7279 - 7249 - Return equipment to normal operating condition; Remark:
Procedure Step
Published
04/27/2023 4:13 PM
7249 - Return equipment to normal operating condition
Instruction
Published
04/08/2025 3:22 PM
7386 - 7250 - Power on RPM; Remark:7367
Procedure Step
Published
09/01/2023 7:59 PM
7250 - Power on RPM
Instruction
Published
05/01/2023 8:31 AM
7367 - Move LD-260 switch to ON position. The PWR ON
Remark
Published
05/11/2023 12:42 PM
7387 - 7368 - Verify power and connectivity; Remark:7369
Procedure Step
Published
05/04/2023 4:31 PM
7368 - Verify power and connectivity
Instruction
Published
05/11/2023 12:42 PM
7369 - POWER and communications LEDs will be constantly on or blinking.
Remark
Published
05/10/2023 2:12 PM
7388 - 7304 - Confirm RPM has restarted correctly; Remark:7370
Procedure Step
Published
05/04/2023 4:32 PM
7304 - Confirm RPM has restarted correctly
Instruction
Published
05/01/2023 8:31 AM
7370 - The SC-770 will perform Power On Self-Test (POST) followed by a background me...
Remark
Published
05/10/2023 9:14 AM
7389 - 7254 - Confirm network connection; Remark:7255
Procedure Step
Published
05/04/2023 4:33 PM
7254 - Confirm network connection
Instruction
Published
04/27/2023 2:22 PM
7255 - Contact operators to confirm communications have been reestablished between RPM ...
Remark
Published
05/10/2023 3:15 PM
7390 - 7256 - Close and lock all RPM doors; Remark:
Procedure Step
Published
05/04/2023 4:34 PM
7256 - Close and lock all RPM doors
Instruction
Published
04/27/2023 2:21 PM
7842 - 7820 - Inform system operators upon completion of maintenance action; Remark:
Procedure Step
Published
07/07/2023 11:15 PM
7820 - Inform system operators upon completion of maintenance action
Instruction
Published
07/07/2023 10:02 PM
322 - 321 - Document maintenance actions; Remark:
Procedure Step
Published
06/17/2021 9:49 AM
321 - Document maintenance actions
Instruction
Published
04/21/2025 11:19 AM
2869 - 2585 - Document maintenance performed; Remark:2866
Procedure Step
Published
06/18/2021 5:58 PM
2585 - Document maintenance performed
Instruction
Published
07/09/2021 12:15 PM
2866 - Record observations, times, and results for the maintenance report.
Remark
Published
04/21/2025 11:39 AM
4706 - 4705 - Submit report; Remark:4864
Procedure Step
Published
06/29/2022 9:50 AM
4705 - Submit report
Instruction
Published
06/29/2022 9:50 AM
4864 - As specified by management or contractual obligations.
Remark
Published
07/28/2022 1:36 PM
Corrective Maintenance Procedure
Document Type
Published
03/02/2020 3:32 PM
Instrument is not functioning correctly
Frequency
Published
12/19/2022 5:52 PM
Warning
Annotation Type
Published
03/02/2020 3:25 PM
Note
Annotation Type
Published
03/02/2020 3:25 PM
Caution
Annotation Type
Published
03/02/2020 3:24 PM
Technician 2
Skill Level
Published
04/09/2020 1:17 AM
Keys to access RPM
Replacement Parts
Published
04/27/2023 6:56 PM
Medium Phillips (PH2) screwdriver
Tools
Published
04/24/2020 4:40 PM
Small slotted precision screwdriver
Replacement Parts
Published
05/04/2023 4:38 PM
Orange/yellow safety vest
Replacement Parts
Published
04/27/2023 6:56 PM
Safety shoes
Replacement Parts
Published
04/27/2023 6:56 PM
Gloves
Replacement Parts
Published
05/10/2023 3:28 PM
Protective headwear: glasses, hard hat
Replacement Parts
Published
05/10/2023 3:31 PM
Orange traffic cones
Replacement Parts
Published
04/27/2023 6:56 PM
LD-260 Disconnect Switch Power Off
Image
Published
04/24/2023 12:49 PM
Magnum CS14P Premium Rated Converter Switch
Image
Published
05/04/2023 1:38 PM
Magnum CS14P Premium Rated Converter Switch Loosen Screw
Image
Published
05/04/2023 1:46 PM
Magnum CS14P Premium Rated Converter Switch Screws
Image
Published
05/04/2023 1:53 PM
Magnum CS14P Premium Rated Converter Switch Screws
Image
Published
05/04/2023 4:50 PM
Magnum CS14P Premium Rated Converter Switch Tighten Screws
Image
Published
05/04/2023 2:11 PM
Magnum CS14P Premium Rated Converter Switch Connectors
Image
Published
05/04/2023 3:31 PM
LD-260 Disconnect Switch Power On
Image
Published
05/04/2023 3:37 PM
Magnum CS14P Premium Rated Converter Switch LEDs.png
Image
Published
05/04/2023 3:41 PM

RPM LD-260 Load Disconnect Replacement

Last Updated: 05/02/2025 1:42 AM

The following table lists all the components that make up the document.

Title Type Status Last Updated
Rapiscan PM-700 Pedestrian Monitor
Device
Published
06/20/2024 11:38 AM
Rapiscan VM-250 Vehicle Monitor
Device
Published
10/14/2024 9:50 AM
Rapiscan TM-850 Rail Monitor
Device
Published
09/18/2024 10:28 AM
7264 - 1401 - Establish Initial Conditions; Remark:
Procedure Step
Published
04/27/2023 7:00 PM
1401 - Establish Initial Conditions
Instruction
Published
09/30/2022 3:14 PM
7268 - 7231 - Close lane; Remark:7233
Procedure Step
Published
04/27/2023 7:01 PM
9053 - Warning : Traffic should temporarily be rerouted or halted during conduction of this pr...
Annotation
Published
09/27/2023 9:09 AM
7231 - Close lane
Instruction
Published
04/18/2023 1:00 PM
7233 - Use orange safety (traffic control) cones to setup barriers. Practice establi...
Remark
Published
04/24/2023 12:18 PM
7269 - 7232 - Open RPM door; Remark:7234
Procedure Step
Published
04/27/2023 7:02 PM
7232 - Open RPM door
Instruction
Published
04/18/2023 1:02 PM
7234 - Open all doors needed to access components.
Remark
Published
04/19/2025 7:48 PM
7270 - 7235 - Power off RPM; Remark:7236
Procedure Step
Published
09/01/2023 7:57 PM
7235 - Power off RPM
Instruction
Published
04/24/2023 12:30 PM
7236 - Move LD-260 switch to OFF position. The PWR ON
Remark
Published
04/27/2023 4:25 PM
7271 - 7237 - Uninstall Faulty LD-260; Remark:
Procedure Step
Published
04/27/2023 7:05 PM
7237 - Uninstall Faulty LD-260
Instruction
Published
04/24/2023 1:09 PM
7272 - 7238 - Disconnect three (3) connectors; Remark:7239
Procedure Step
Published
04/27/2023 7:06 PM
5291 - Note : It is good practice to verify all cables and connectors are labeled prior to ...
Annotation
Published
10/24/2022 8:35 AM
7238 - Disconnect three (3) connectors
Instruction
Published
04/24/2023 12:38 PM
7239 - Needle nose pliers can be used to remove connectors.
Remark
Published
05/10/2023 3:08 PM
7273 - 7240 - Remove two (2) mounting screw; Remark:7241
Procedure Step
Published
04/27/2023 4:09 PM
7240 - Remove two (2) mounting screws
Instruction
Published
04/05/2025 2:39 PM
7241 - Use medium Phillips (PH2) screwdriver. Retain screws.
Remark
Published
05/10/2023 3:09 PM
7274 - 7242 - Remove faulty LD-260; Remark:
Procedure Step
Published
04/27/2023 4:09 PM
7242 - Remove faulty LD-260
Instruction
Published
05/10/2023 3:10 PM
3397 - 3395 - Label faulty component; Remark:3396
Procedure Step
Published
07/21/2024 6:59 AM
3395 - Label faulty component
Instruction
Published
08/07/2021 11:07 AM
3396 - Use tag or tape. Include date of removal, description of failure symptoms, co...
Remark
Published
08/09/2021 11:35 AM
7276 - 7245 - Install New LD-260; Remark:
Procedure Step
Published
04/27/2023 4:11 PM
7245 - Install New LD-260
Instruction
Published
05/10/2023 3:11 PM
7277 - 7246 - Mount new LD-260; Remark:7247
Procedure Step
Published
04/27/2023 7:07 PM
7246 - Mount new LD-260
Instruction
Published
05/10/2023 3:12 PM
7247 - Use retained screws. Use medium Phillips (PH2) screwdriver.
Remark
Published
05/10/2023 3:12 PM
7278 - 7248 - Reconnect three (3) connectors; Remark:7411
Procedure Step
Published
05/08/2023 8:31 AM
7263 - Caution : Correct placement of connectors and wiring is critical to proper operation.
Annotation
Published
04/24/2023 2:32 PM
7248 - Reconnect three (3) connectors
Instruction
Published
05/10/2023 3:13 PM
7411 - Reconnect three (3) connectors
Remark
Published
05/08/2023 8:30 AM
7279 - 7249 - Return equipment to normal operating condition; Remark:
Procedure Step
Published
04/27/2023 4:13 PM
7249 - Return equipment to normal operating condition
Instruction
Published
04/08/2025 3:22 PM
7280 - 7250 - Power on RPM; Remark:7251
Procedure Step
Published
04/27/2023 4:14 PM
7250 - Power on RPM
Instruction
Published
05/01/2023 8:31 AM
7251 - Move LD-260 switch to ON position. The LED PWR ON
Remark
Published
05/10/2023 3:14 PM
7281 - 7252 - Verify RPM start-up; Remark:7253
Procedure Step
Published
04/20/2025 3:26 PM
7252 - Verify RPM start-up
Instruction
Published
04/27/2023 2:23 PM
7253 - RPM will perform a power on self-test (POST) and collect a background radiati...
Remark
Published
05/10/2023 3:14 PM
7282 - 7254 - Confirm network connection; Remark:7255
Procedure Step
Published
04/27/2023 4:15 PM
7254 - Confirm network connection
Instruction
Published
04/27/2023 2:22 PM
7255 - Contact operators to confirm communications have been reestablished between RPM ...
Remark
Published
05/10/2023 3:15 PM
7283 - 7256 - Close and lock all RPM doors; Remark:
Procedure Step
Published
09/01/2023 11:45 PM
7256 - Close and lock all RPM doors
Instruction
Published
04/27/2023 2:21 PM
7842 - 7820 - Inform system operators upon completion of maintenance action; Remark:
Procedure Step
Published
07/07/2023 11:15 PM
7820 - Inform system operators upon completion of maintenance action
Instruction
Published
07/07/2023 10:02 PM
322 - 321 - Document maintenance actions; Remark:
Procedure Step
Published
06/17/2021 9:49 AM
321 - Document maintenance actions
Instruction
Published
04/21/2025 11:19 AM
2869 - 2585 - Document maintenance performed; Remark:2866
Procedure Step
Published
06/18/2021 5:58 PM
2585 - Document maintenance performed
Instruction
Published
07/09/2021 12:15 PM
2866 - Record observations, times, and results for the maintenance report.
Remark
Published
04/21/2025 11:39 AM
4706 - 4705 - Submit report; Remark:4864
Procedure Step
Published
06/29/2022 9:50 AM
4705 - Submit report
Instruction
Published
06/29/2022 9:50 AM
4864 - As specified by management or contractual obligations.
Remark
Published
07/28/2022 1:36 PM
Corrective Maintenance Procedure
Document Type
Published
03/02/2020 3:32 PM
Instrument is not functioning correctly
Frequency
Published
12/19/2022 5:52 PM
Warning
Annotation Type
Published
03/02/2020 3:25 PM
Note
Annotation Type
Published
03/02/2020 3:25 PM
Caution
Annotation Type
Published
03/02/2020 3:24 PM
Technician 2
Skill Level
Published
04/09/2020 1:17 AM
Keys to access RPM
Replacement Parts
Published
04/27/2023 6:56 PM
Medium Phillips (PH2) screwdriver
Tools
Published
04/24/2020 4:40 PM
Needle nose pliers
Tools
Published
05/06/2020 4:10 PM
Orange/yellow safety vest
Replacement Parts
Published
04/27/2023 6:56 PM
Safety shoes
Replacement Parts
Published
04/27/2023 6:56 PM
Gloves
Replacement Parts
Published
05/10/2023 3:28 PM
Protective headwear: glasses, hard hat
Replacement Parts
Published
05/10/2023 3:31 PM
Orange traffic cones
Replacement Parts
Published
04/27/2023 6:56 PM
LD-260 Disconnect Switch Power Off
Image
Published
04/24/2023 12:49 PM
LD-260 Disconnect Switch Connector Removal
Image
Published
04/24/2023 12:57 PM
LD-260 Disconnect Switch Screw Locations
Image
Published
04/24/2023 1:03 PM
LD-260 Disconnect Switch Connector Install
Image
Published
04/24/2023 1:19 PM
LD-260 Disconnect Switch Power On
Image
Published
05/04/2023 3:37 PM