Last Updated: 04/24/2025 1:44 AM

The following table lists all the components that make up the document.

Title Type Status Last Updated
Rapiscan VM-250 Vehicle Monitor
Device
Published
10/14/2024 9:50 AM
Rapiscan PM-700 Pedestrian Monitor
Device
Published
06/20/2024 11:38 AM
Rapiscan TM-850 Rail Monitor
Device
Published
09/18/2024 10:28 AM
7738 - 7646 - Prepare RPM Specific FCT Datasheet; Remark:
Procedure Step
Published
07/03/2023 10:36 AM
7647 - Note : Step 1 (1 through 1-4) should be performed before traveling to the RPMs. ...
Annotation
Published
06/30/2023 1:12 PM
7646 - Prepare RPM Specific FCT Datasheet
Instruction
Published
06/30/2023 1:11 PM
7739 - 7648 - Open most recent baselined FCT datasheet on laptop; Remark:
Procedure Step
Published
07/02/2023 12:27 PM
7648 - Open most recent baselined FCT datasheet on laptop
Instruction
Published
06/30/2023 1:14 PM
7740 - 7649 - Save file with unique name (add today's date) and close master copy; Remark:7650
Procedure Step
Published
07/02/2023 12:28 PM
7649 - Save file with unique name (add today's date) and close master copy
Instruction
Published
06/30/2023 1:15 PM
7650 - An example of a unique file name is US_PortofEntry_FCT_Lane1_05132016...
Remark
Published
07/02/2023 3:00 AM
7741 - 7651 - Enter date of procedure performance in appropriate cell; Remark:
Procedure Step
Published
07/02/2023 12:30 PM
7652 - Note : Date of procedure in FCT datasheet is extremely important for correct radioac...
Annotation
Published
07/02/2023 5:22 PM
7651 - Enter date of procedure performance in appropriate cell
Instruction
Published
06/30/2023 1:19 PM
7742 - 7653 - Enter RPM identification information; Remark:7654
Procedure Step
Published
07/02/2023 12:32 PM
7653 - Enter RPM identification information
Instruction
Published
06/30/2023 1:21 PM
7654 - Complete the General Information section to specifically identify the RPM (se...
Remark
Published
07/02/2023 3:01 AM
7743 - 7655 - Verify Gamma Radioactive Source is Sufficient for FCT; Remark:
Procedure Step
Published
07/02/2023 12:37 PM
7655 - Verify Gamma Radioactive Source is Sufficient for FCT
Instruction
Published
07/02/2023 5:23 PM
7744 - 7656 - Enter Co-57 source identification number; Remark:7657
Procedure Step
Published
07/02/2023 12:40 PM
7656 - Enter Co-57 source identification number
Instruction
Published
06/30/2023 2:26 PM
7657 - Source information is commonly listed directly on the label of radioactive so...
Remark
Published
07/02/2023 3:01 AM
7745 - 7658 - Enter Co-57 initial activity in kBq (as listed on source label or source cert...; Remark:7659
Procedure Step
Published
07/02/2023 12:40 PM
7658 - Enter Co-57 initial activity in kBq (as listed on source label or source cert...
Instruction
Published
06/30/2023 2:35 PM
7659 - Source Activity Level
Remark
Published
07/02/2023 3:02 AM
7746 - 7660 - Enter Co-57 source calibration date; Remark:7661
Procedure Step
Published
07/02/2023 12:42 PM
7660 - Enter Co-57 source calibration date
Instruction
Published
06/30/2023 2:46 PM
7661 - Source Calibration Date
Remark
Published
07/02/2023 3:02 AM
7747 - 7662 - Verify Co-57 calculated current activity is within specified limits; Remark:7664
Procedure Step
Published
04/13/2025 6:20 PM
7663 - Standard : Current Co-57 source activity must be between 19 and 400 kBq to perform this ...
Annotation
Published
07/02/2023 5:24 PM
7662 - Verify Co-57 calculated current activity is within specified limits
Instruction
Published
04/13/2025 5:49 PM
7664 - Source Current Activity Level
Remark
Published
07/02/2023 3:03 AM
7748 - 7665 - Verify Neutron Radioactive Source is Sufficient for FCT ...; Remark:
Procedure Step
Published
07/02/2023 12:46 PM
7665 - Verify Neutron Radioactive Source is Sufficient for FCT ...
Instruction
Published
06/30/2023 2:59 PM
7749 - 7666 - Enter Cf-252 source identification number; Remark:7667
Procedure Step
Published
07/02/2023 12:48 PM
7666 - Enter Cf-252 source identification number
Instruction
Published
06/30/2023 3:00 PM
7667 - Source information is commonly listed directly on the label of the radioactiv...
Remark
Published
07/03/2023 10:21 AM
7750 - 7668 - Enter Cf-252 source activity in kBq (as listed on source label or source cert...; Remark:7669
Procedure Step
Published
07/02/2023 12:49 PM
7668 - Enter Cf-252 source activity in kBq (as listed on source label or source cert...
Instruction
Published
06/30/2023 3:23 PM
7669 -
Remark
Published
07/02/2023 12:51 PM
7751 - 7670 - Enter Cf-252 source calibration date; Remark:7671
Procedure Step
Published
07/02/2023 12:52 PM
7670 - Enter Cf-252 source calibration date
Instruction
Published
06/30/2023 3:35 PM
7671 - Certificate of Calibration Neutron Date
Remark
Published
07/02/2023 3:04 AM
7752 - 7673 - Verify Cf-252 calculated current activity is within specified limits; Remark:7674
Procedure Step
Published
07/02/2023 12:54 PM
7672 - Standard : Current Cf-252 source activity must be between 37 and 185 kBq to perform this...
Annotation
Published
06/30/2023 3:42 PM
7673 - Verify Cf-252 calculated current activity is within specified limits
Instruction
Published
06/30/2023 3:44 PM
7674 - Current Cf-252 source activity must be between 2,000 and 20,000 n/s to perfor...
Remark
Published
07/02/2023 3:05 AM
7621 - 1401 - Establish Initial Conditions; Remark:
Procedure Step
Published
06/29/2023 5:37 PM
1401 - Establish Initial Conditions
Instruction
Published
09/30/2022 3:14 PM
7622 - 7592 - Inform system operators; Remark:11335
Procedure Step
Published
04/20/2025 10:15 AM
7592 - Inform system operators
Instruction
Published
06/29/2023 3:20 PM
11335 - Upon arrival, brief system operators on expected work, duration, anticipated ...
Remark
Published
04/20/2025 10:14 AM
7753 - 7676 - Brief system operators on expected work, duration, anticipated alarms, and fa...; Remark:7677
Procedure Step
Published
07/02/2023 1:53 PM
7676 - Brief system operators on expected work, duration, anticipated alarms, and fa...
Instruction
Published
07/01/2023 11:39 PM
7677 - Operators should expect numerous fault indications and alarms during procedur...
Remark
Published
07/02/2023 3:05 AM
7754 - 7594 - Close lane and set up barriers to establish a safety watch; Remark:7595
Procedure Step
Published
07/02/2023 1:55 PM
7678 - Warning : Traffic should temporarily be rerouted or halted during conduction of this pr...
Annotation
Published
07/03/2023 10:23 AM
7594 - Close lane and set up barriers to establish a safety watch
Instruction
Published
06/29/2023 3:28 PM
7595 - Use orange safety (traffic control) cones or equivalent per site-specific saf...
Remark
Published
06/29/2023 3:33 PM
7755 - 7679 - Disconnect Ethernet; Remark:11336
Procedure Step
Published
04/20/2025 11:18 AM
7680 - Caution : Make sure to press release button on back of Ethernet cable before removing.
Annotation
Published
07/01/2023 11:54 PM
7679 - Disconnect Ethernet
Instruction
Published
07/01/2023 11:52 PM
11336 - Locate Ethernet connector on top of SC-770 controller. Press release button o...
Remark
Published
04/20/2025 11:21 AM
7756 - 7681 - Disable occupancy sensor; Remark:7682
Procedure Step
Published
07/02/2023 1:59 PM
7681 - Disable occupancy sensor
Instruction
Published
07/01/2023 11:55 PM
7682 - For vehicle monitor, disconnect both break-beam sensor receivers (usually*) l...
Remark
Published
07/02/2023 3:06 AM
7757 - 344 - Verify parameter settings are correct; Remark:
Procedure Step
Published
07/02/2023 2:00 PM
344 - Verify parameter settings are correct
Instruction
Published
07/03/2023 10:24 AM
7280 - 7250 - Power on RPM; Remark:7251
Procedure Step
Published
04/27/2023 4:14 PM
7250 - Power on RPM
Instruction
Published
05/01/2023 8:31 AM
7251 - Move LD-260 switch to ON position. The LED PWR ON
Remark
Published
05/10/2023 3:14 PM
7281 - 7252 - Verify RPM start-up; Remark:7253
Procedure Step
Published
04/20/2025 3:26 PM
7252 - Verify RPM start-up
Instruction
Published
04/27/2023 2:23 PM
7253 - RPM will perform a power on self-test (POST) and collect a background radiati...
Remark
Published
05/10/2023 3:14 PM
7760 - 7683 - Record SC-770 parameter values; Remark:7684
Procedure Step
Published
07/02/2023 2:09 PM
7685 - Caution : Each SC-770 parameter must match the values obtained from the LANL configurat...
Annotation
Published
07/02/2023 12:20 AM
7683 - Record SC-770 parameter values
Instruction
Published
07/02/2023 12:09 AM
7684 - Enter Program Mode by pressing "0." Enter the password 1234...
Remark
Published
07/02/2023 3:06 AM
7761 - 7686 - Manually enter variable values; Remark:7687
Procedure Step
Published
07/02/2023 2:12 PM
7686 - Manually enter variable values
Instruction
Published
07/02/2023 12:22 AM
7687 - Variable values include parameters such as N*Sigma and Alpha value.
Remark
Published
04/13/2025 5:49 PM
7762 - 7688 - Click the check box to confirm fixed values; Remark:
Procedure Step
Published
04/13/2025 6:20 PM
7688 - Click the check box to confirm fixed values
Instruction
Published
04/13/2025 5:49 PM
7763 - 7689 - Return to SC-770 main menu; Remark:7690
Procedure Step
Published
07/02/2023 2:14 PM
7689 - Return to SC-770 main menu
Instruction
Published
07/02/2023 12:28 AM
7690 - Press "#" button until the SC-770 displays the main menu.
Remark
Published
04/13/2025 5:50 PM
7764 - 7691 - Perform Gamma Detector Efficiency Measurements; Remark:
Procedure Step
Published
04/13/2025 6:20 PM
7691 - Perform Gamma Detector Efficiency Measurements
Instruction
Published
04/13/2025 5:50 PM
7765 - 7694 - Navigate SC-770 to SHOW COUNTS for gamma detectors; Remark:7695
Procedure Step
Published
07/02/2023 2:18 PM
7692 - Caution : Keep gamma detectors protected from direct sunlight.
Annotation
Published
04/13/2025 5:50 PM
7693 - Note : Verify there are no radiation sources sources within 20 meters of the RPM whi...
Annotation
Published
07/02/2023 12:40 AM
7694 - Navigate SC-770 to SHOW COUNTS for gamma detectors
Instruction
Published
07/02/2023 12:41 AM
7695 - From SC-770 main programming menu, press GAMMA
Remark
Published
04/13/2025 5:52 PM
7766 - 7696 - Record measured gamma background count rate for each gamma detector; Remark:7697
Procedure Step
Published
07/02/2023 2:19 PM
7696 - Record measured gamma background count rate for each gamma detector
Instruction
Published
07/02/2023 12:57 AM
7697 - Stand clear of all gamma detectors, watch displayed count rate for each chann...
Remark
Published
07/02/2023 3:07 AM
7767 - 7700 - Place label side of Co-57 gamma source against yellow dot at center of detect...; Remark:7701
Procedure Step
Published
07/02/2023 2:23 PM
7698 - Standard : Due to low energy of Co-57 gammas, the count rate on either side of the sourc...
Annotation
Published
07/02/2023 1:07 AM
7699 - Note : Verify distance between source and detector is minimized to warrant accurate ...
Annotation
Published
07/02/2023 1:08 AM
7700 - Place label side of Co-57 gamma source against yellow dot at center of detect...
Instruction
Published
07/02/2023 1:09 AM
7701 - The source must be held firmly against the detector with a low-density tool s...
Remark
Published
07/02/2023 3:08 AM
7768 - 7702 - Record gamma count rate in appropriate "Source Count Rate (Co-57)" cell; Remark:7704
Procedure Step
Published
07/02/2023 2:25 PM
7703 - Note : Verify that there are no additional radiation sources within 20 meters of the...
Annotation
Published
07/02/2023 1:17 AM
7702 - Record gamma count rate in appropriate "Source Count Rate (Co-57)" cell
Instruction
Published
07/02/2023 1:15 AM
7704 - Stand clear of all gamma detectors, watch displayed count rate for each chann...
Remark
Published
07/02/2023 1:23 AM
7769 - 7705 - Repeat for each gamma detector in RPM; Remark:
Procedure Step
Published
07/02/2023 2:27 PM
7705 - Repeat for each gamma detector in RPM
Instruction
Published
07/02/2023 1:25 AM
7770 - 7707 - Verify gamma detector efficiency; Remark:7708
Procedure Step
Published
04/13/2025 6:20 PM
7706 - Standard : Gamma detector efficiency should be greater than 20%
Annotation
Published
07/02/2023 1:31 AM
7707 - Verify gamma detector efficiency
Instruction
Published
04/13/2025 5:52 PM
7708 - Gamma Detector Efficiency
Remark
Published
07/02/2023 3:08 AM
7771 - 7709 - Go to SC-770 main menu; Remark:7710
Procedure Step
Published
07/02/2023 2:31 PM
7709 - Go to SC-770 main menu
Instruction
Published
07/02/2023 1:41 AM
7710 - Press "#" button until the SC-770 displays the main menu.
Remark
Published
07/02/2023 3:09 AM
7772 - 7711 - Perform Neutron Detector Efficiency Measurements; Remark:
Procedure Step
Published
07/02/2023 2:33 PM
7711 - Perform Neutron Detector Efficiency Measurements
Instruction
Published
07/02/2023 1:49 AM
7773 - 7712 - Enter "fixed" neutron background count rate for each neutron detector; Remark:7713
Procedure Step
Published
07/02/2023 2:34 PM
7712 - Enter "fixed" neutron background count rate for each neutron detector
Instruction
Published
07/02/2023 1:52 AM
7713 - Record 1 counts per second (cps) for each neutron tube installed on each chan...
Remark
Published
07/02/2023 2:00 AM
7774 - 7714 - Navigate SC-770 to SHOW COUNTS for neutron detectors; Remark:7715
Procedure Step
Published
07/02/2023 2:36 PM
7714 - Navigate SC-770 to SHOW COUNTS for neutron detectors
Instruction
Published
07/02/2023 2:02 AM
7715 - From SC-770 main programming menu, press NEUTRON ...
Remark
Published
04/13/2025 6:19 PM
7775 - 7718 - Place Cf-252 neutron source against yellow dot on center of detector; Remark:7719
Procedure Step
Published
07/02/2023 2:37 PM
7716 - Warning : Do not hold the neutron source on the detector face with your hand or stand n...
Annotation
Published
07/02/2023 2:07 AM
7717 - Note : During the neutron detector efficiency tests, verify no one is near t...
Annotation
Published
07/02/2023 2:10 AM
7718 - Place Cf-252 neutron source against yellow dot on center of detector
Instruction
Published
07/02/2023 2:12 AM
7719 - It is acceptable to use adhesive tape for this step
Remark
Published
04/13/2025 5:54 PM
7776 - 7720 - Record neutron count rate in appropriate "Source Count Rate (Cf-252)" cell; Remark:7722
Procedure Step
Published
07/02/2023 2:38 PM
7721 - Note : Ensure that threre are no additional radiation sources within 20 meters of th...
Annotation
Published
07/02/2023 2:18 AM
7720 - Record neutron count rate in appropriate "Source Count Rate (Cf-252)" cell
Instruction
Published
07/02/2023 2:15 AM
7722 - Stand clear of all neutron detectors, watch displayed count rate for each cha...
Remark
Published
07/02/2023 2:22 AM
7777 - 7723 - Repeat for all neutron detectors in RPM; Remark:
Procedure Step
Published
07/02/2023 2:40 PM
7723 - Repeat for all neutron detectors in RPM
Instruction
Published
07/02/2023 2:24 AM
7778 - 7724 - Verify neutron detector efficiency; Remark:7726
Procedure Step
Published
07/02/2023 2:42 PM
7725 - Standard : Neutron detector efficiency should be greater than 5% (VM with 2 helium tubes...
Annotation
Published
07/02/2023 2:27 AM
7724 - Verify neutron detector efficiency
Instruction
Published
07/02/2023 2:25 AM
7726 - Neutron Source Efficiency
Remark
Published
07/02/2023 2:29 AM
7279 - 7249 - Return equipment to normal operating condition; Remark:
Procedure Step
Published
04/27/2023 4:13 PM
7249 - Return equipment to normal operating condition
Instruction
Published
04/08/2025 3:22 PM
7780 - 7728 - Exit SC-770 programming mode; Remark:7729
Procedure Step
Published
07/02/2023 2:44 PM
7728 - Exit SC-770 programming mode
Instruction
Published
07/02/2023 2:33 AM
7729 - Press "#" until SC-770 exits programming mode and return to normal operating ...
Remark
Published
07/02/2023 2:34 AM
7781 - 7730 - Reconnect Ethernet; Remark:7731
Procedure Step
Published
04/20/2025 11:00 AM
7730 - Reconnect Ethernet
Instruction
Published
07/02/2023 2:34 AM
7731 - Insert Ethernet connector at top of SC-770 module. Connector will audibly "cl...
Remark
Published
07/02/2023 2:36 AM
7782 - 319 - Perform operational test; Remark:7734
Procedure Step
Published
07/02/2023 2:47 PM
7732 - Caution : It is critical that the RPM be returned to the proper operational configurati...
Annotation
Published
07/02/2023 2:39 AM
319 - Perform operational test
Instruction
Published
06/10/2021 8:31 PM
7734 - Perform procedure DET-RPM-RAP‐RM03 RPM Operational Testing.
Remark
Published
07/02/2023 2:43 AM
7842 - 7820 - Inform system operators upon completion of maintenance action; Remark:
Procedure Step
Published
07/07/2023 11:15 PM
7820 - Inform system operators upon completion of maintenance action
Instruction
Published
07/07/2023 10:02 PM
322 - 321 - Document maintenance actions; Remark:
Procedure Step
Published
06/17/2021 9:49 AM
321 - Document maintenance actions
Instruction
Published
04/21/2025 11:19 AM
2869 - 2585 - Document maintenance performed; Remark:2866
Procedure Step
Published
06/18/2021 5:58 PM
2585 - Document maintenance performed
Instruction
Published
07/09/2021 12:15 PM
2866 - Record observations, times, and results for the maintenance report.
Remark
Published
04/21/2025 11:39 AM
4706 - 4705 - Submit report; Remark:4864
Procedure Step
Published
06/29/2022 9:50 AM
4705 - Submit report
Instruction
Published
06/29/2022 9:50 AM
4864 - As specified by management or contractual obligations.
Remark
Published
07/28/2022 1:36 PM
Routine Maintenance Procedure
Document Type
Published
03/02/2020 3:31 PM
Annually
Frequency
Published
04/01/2020 11:37 AM
As specified by corrective maintenance retest requirements following guidance from the Nuclear Smuggling Detection and Deterrence (NSDD) Program
Frequency
Published
07/02/2023 3:28 PM
Note
Annotation Type
Published
03/02/2020 3:25 PM
Standard
Annotation Type
Published
03/02/2020 3:25 PM
Warning
Annotation Type
Published
03/02/2020 3:25 PM
Caution
Annotation Type
Published
03/02/2020 3:24 PM
Technician 1
Skill Level
Published
05/14/2020 2:56 PM
Technician 2
Skill Level
Published
04/09/2020 1:17 AM
Keys to access RPM
Replacement Parts
Published
04/27/2023 6:56 PM
Reflective safety vest if required
Replacement Parts
Published
06/20/2023 4:47 PM
safety glasses
Replacement Parts
Published
07/02/2023 4:48 PM
Ladder; 2 meters, 6 feet tall; non-conducting if required
Replacement Parts
Published
07/02/2023 4:48 PM
Traffic control cones or equivalent if required
Replacement Parts
Published
06/20/2023 4:47 PM
Source-holding device ~ 1.5 m long extending rod or pole
Replacement Parts
Published
07/02/2023 4:48 PM
Flashlight/headlight is recommended
Replacement Parts
Published
07/02/2023 4:48 PM
Laptop computer with current baselined functional compliance test, FCT, datasheet
Replacement Parts
Published
07/02/2023 4:48 PM
Functional Compliance Testting Data
Image
Published
06/30/2023 1:26 PM
Source Activity Label
Image
Published
06/30/2023 2:37 PM
Certificate of Calibration Source Activity
Image
Published
06/30/2023 2:38 PM
Source Calibration Date
Image
Published
06/30/2023 2:43 PM
Certificate of Calibration Source Date
Image
Published
06/30/2023 2:44 PM
Certificate of Calibration Current Source Activity
Image
Published
06/30/2023 2:51 PM
Certificate of Calibration Current Neutron Date
Image
Published
06/30/2023 3:37 PM
Certificate of Calibration Current Neutron Current Level
Image
Published
06/30/2023 3:45 PM
Disconnect Ethernet cable on top of SC-770 box
Image
Published
10/04/2023 2:59 PM
LD-260 Disconnect Switch Power On
Image
Published
05/04/2023 3:37 PM
SC-770 Main Menu
Image
Published
07/02/2023 12:29 AM
Record Measured Gamma Background
Image
Published
07/02/2023 12:56 AM
Gamma Count in Co-57 Source
Image
Published
07/02/2023 1:20 AM
Gamma Detector Efficiency
Image
Published
07/02/2023 1:39 AM
Neutron Background Count Rate
Image
Published
07/02/2023 1:54 AM
Neutron Count Rate
Image
Published
07/02/2023 2:21 AM
Neutron Source Efficiency
Image
Published
07/02/2023 2:28 AM
Functional Compliance Test Results
Image
Published
07/02/2023 2:43 AM
DET-RPM-RAP-RM05

Perform functional compliance testing of radiation portal monitor (RPM)

Equipment Hierarchy
Rapiscan VM-250 Vehicle Monitor
Rapiscan PM-700 Pedestrian Monitor
Rapiscan TM-850 Rail Monitor
Frequency
Annually
As specified by corrective maintenance retest requirements following guidance from the Nuclear Smuggling Detection and Deterrence (NSDD) Program
Technician Level
Technician Level
Technician 1
x 1
Technician Level
Technician 2
x 1
Duration
Notes

Per RPM

Length of time
30
Tools Required
Keys to access RPM
Reflective safety vest if required
safety glasses
Ladder; 2 meters, 6 feet tall; non-conducting if required
Traffic control cones or equivalent if required
Source-holding device ~ 1.5 m long extending rod or pole
Flashlight/headlight is recommended
Laptop computer with current baselined functional compliance test, FCT, datasheet
Materials Required
SC-770 parameter settings for each RPM at the site
Radioactive check sources
Vehicle and Pedestrian Monitor VM-250AGN/PM-700AGN Operations & Service Manual
Originators
Craig Stinson
Bailey Toon
Brian Tucker
Originating Organization
PNNL
Approver
Jamie Hughes
Safety Concerns
Electrical
Radioactive Source
Final Documentation
Completed FCT datasheet
Routine maintenance report
Departmental Coordination

Coordinate site access with system operators

Date of Origin
Version
1.00
Version #
Revision #
1.00
Revision Description

Updated pillar names

Revision Author
Preparation
Step 1
Main Step
Preparation
Step 2

7744 - 7656 - Enter Co-57 source identification number; Remark:7657

Step 00

7657 - Source information is commonly listed directly on the label of radioactive so...

Source information is commonly listed directly on the label of radioactive source; however, this may also be obtained from the Certificate of Calibration that is provided with all radioactive sources.

Gamma and neutron check source activities have a significant impact on the results obtained during RPM functional testing. Entering accurate source information into the datasheet is crucial to successful completion of this procedure. 

Preparation
Step 3

7749 - 7666 - Enter Cf-252 source identification number; Remark:7667

Step 00

7667 - Source information is commonly listed directly on the label of the radioactiv...

Source information is commonly listed directly on the label of the radioactive source; however, this may also be obtained from the Certificate of Calibration that is provided with all radioactive sources. 

Gamma and neutron check source activities have a significant impact on the results obtained during RPM functional testing. Entering accurate source information into the datasheet is crucial to successful completion of this procedure. 

7752 - 7673 - Verify Cf-252 calculated current activity is within specified limits; Remark:7674

Step 00
Preparation
Step 4

7754 - 7594 - Close lane and set up barriers to establish a safety watch; Remark:7595

Step 00

7756 - 7681 - Disable occupancy sensor; Remark:7682

Step 00

7682 - For vehicle monitor, disconnect both break-beam sensor receivers (usually*) l...

For vehicle monitor, disconnect both break-beam sensor receivers (usually*) located in the control pillar, and then disconnect 12 Vdc to the ultrasonic sensor in the auxiliary pillar.

For pedestrian monitor, place a piece of black tape over sensor of infrared curtain (SPY-2), or simply stand clear of occupancy sensor when door is opened. Disabling the sensors will prevent the RPM from sensing an occupied condition and going into fast-count mode when the RPM doors are opened or a maintenance technician is working in and around the pillars.

*In some installations, break-beam sensor receivers have been moved to the auxiliary pillar. It is important that receivers be disconnected; if the transmitters are disconnected a constant state of occupancy will result.

Preparation
Step 5

7760 - 7683 - Record SC-770 parameter values; Remark:7684

Step 00

7684 - Enter Program Mode by pressing "0." Enter the password 1234...

Enter Program Mode by pressing "0."

Enter the password 1234 and press "#" (enter).

Navigation of parameter settings can be found in the Vehicle and Pedestrian Monitor VM-250AGN/PM-700AGN Operations & Service Manual.

If parameter settings do not match currently approved settings from LANL database, set to match. 

Operation
Step 6

7765 - 7694 - Navigate SC-770 to SHOW COUNTS for gamma detectors; Remark:7695

Step 00

7766 - 7696 - Record measured gamma background count rate for each gamma detector; Remark:7697

Step 00

7767 - 7700 - Place label side of Co-57 gamma source against yellow dot at center of detect...; Remark:7701

Step 00

7768 - 7702 - Record gamma count rate in appropriate "Source Count Rate (Co-57)" cell; Remark:7704

Step 00
Operation
Step 7

7773 - 7712 - Enter "fixed" neutron background count rate for each neutron detector; Remark:7713

Step 00

7775 - 7718 - Place Cf-252 neutron source against yellow dot on center of detector; Remark:7719

Step 00

7776 - 7720 - Record neutron count rate in appropriate "Source Count Rate (Cf-252)" cell; Remark:7722

Step 00
Operation
Step 8

7782 - 319 - Perform operational test; Remark:7734

Step 00

7734 - Perform procedure DET-RPM-RAP‐RM03 RPM Operational Testing.

Perform procedure DET-RPM-RAP‐RM03 RPM Operational Testing.


Verify all faults and alarms indicate properly at the RPM if personnel and communication with the CAS are available. 
Verify the faults and alarms are displayed on the CAS workstation at this time as well.


Place a check in each box on the FCT to indicate that each fault and alarm was successful (image below).
 

Image
Test Results
Document Type
Routine Maintenance Procedure
Percent Complete
100.00
Percent Complete W/Media
100.00