Rapiscan VM-250 Vehicle Monitor |
Device
|
Published
|
10/14/2024 9:50 AM
|
Rapiscan PM-700 Pedestrian Monitor |
Device
|
Published
|
06/20/2024 11:38 AM
|
Rapiscan TM-850 Rail Monitor |
Device
|
Published
|
09/18/2024 10:28 AM
|
Rapiscan CM-267 Conveyor Monitor |
Device
|
Published
|
06/27/2024 1:02 PM
|
7621 - 1401 - Establish Initial Conditions; Remark: |
Procedure Step
|
Published
|
06/29/2023 5:37 PM
|
1401 - Establish Initial Conditions |
Instruction
|
Published
|
09/30/2022 3:14 PM
|
7268 - 7231 - Close lane; Remark:7233 |
Procedure Step
|
Published
|
04/27/2023 7:01 PM
|
9053 - Warning : Traffic should temporarily be rerouted or halted during conduction of this pr... |
Annotation
|
Published
|
09/27/2023 9:09 AM
|
7231 - Close lane |
Instruction
|
Published
|
04/18/2023 1:00 PM
|
7233 - Use orange safety (traffic control) cones to setup barriers. Practice establi... |
Remark
|
Published
|
04/24/2023 12:18 PM
|
7269 - 7232 - Open RPM door; Remark:7234 |
Procedure Step
|
Published
|
04/27/2023 7:02 PM
|
7232 - Open RPM door |
Instruction
|
Published
|
04/18/2023 1:02 PM
|
7234 - Open all doors needed to access components. |
Remark
|
Published
|
04/19/2025 7:48 PM
|
8221 - 7676 - Brief system operators on expected work, duration, anticipated alarms, and fa...; Remark: |
Procedure Step
|
Published
|
09/01/2023 9:26 PM
|
7676 - Brief system operators on expected work, duration, anticipated alarms, and fa... |
Instruction
|
Published
|
07/01/2023 11:39 PM
|
9632 - 9609 - Power off AC circuit breaker; Remark:9610 |
Procedure Step
|
Published
|
10/11/2023 3:25 PM
|
9607 - Warning : 110/240 VAC is present at circuit breaker and at the AC line filter. |
Annotation
|
Published
|
04/13/2025 6:03 PM
|
9608 - Note : Normally, the OFF position will be when the circuit breaker ... |
Annotation
|
Published
|
10/11/2023 2:20 PM
|
9609 - Power off AC circuit breaker |
Instruction
|
Published
|
10/11/2023 2:21 PM
|
9610 - The AC circuit breaker is located at the bottom of the control pillar. ... |
Remark
|
Published
|
04/13/2025 6:03 PM
|
9633 - 9611 - Uninstall AC Line Filter; Remark: |
Procedure Step
|
Published
|
10/11/2023 3:26 PM
|
9611 - Uninstall AC Line Filter |
Instruction
|
Published
|
10/11/2023 2:30 PM
|
9634 - 9612 - Confirm no AC voltage is present; Remark:9613 |
Procedure Step
|
Published
|
04/13/2025 6:15 PM
|
9612 - Confirm no AC voltage is present |
Instruction
|
Published
|
04/13/2025 6:02 PM
|
9613 - Using a digital multimeter, place the negative (-) lead on the mounting screw... |
Remark
|
Published
|
10/11/2023 2:36 PM
|
9635 - 9615 - Measure each black wire connection; Remark:9616 |
Procedure Step
|
Published
|
10/11/2023 3:27 PM
|
9614 - Warning : DO NOT proceed if voltage is present at either wire location... |
Annotation
|
Published
|
10/11/2023 2:37 PM
|
9615 - Measure each black wire connection |
Instruction
|
Published
|
10/11/2023 2:40 PM
|
9616 - Using a digital multimeter, place the positive (+) lead on each of the mounti... |
Remark
|
Published
|
10/11/2023 2:44 PM
|
9636 - 9617 - Measure each white wire connection; Remark:9618 |
Procedure Step
|
Published
|
10/11/2023 3:28 PM
|
9617 - Measure each white wire connection |
Instruction
|
Published
|
10/11/2023 2:45 PM
|
9618 - Using a digital multimeter, place the positive (+) lead on each of the mounti... |
Remark
|
Published
|
10/11/2023 2:49 PM
|
9637 - 9619 - Disconnect all wiring; Remark:9620 |
Procedure Step
|
Published
|
10/11/2023 3:29 PM
|
7352 - Note : It is good practice to verify all cables and connectors are labeled prior to ... |
Annotation
|
Published
|
05/03/2023 11:27 AM
|
9619 - Disconnect all wiring |
Instruction
|
Published
|
10/11/2023 2:51 PM
|
9620 - Using a small Phillips screwdriver, disconnect all the wires attached to the ... |
Remark
|
Published
|
10/11/2023 2:52 PM
|
9638 - 9621 - Remove AC line filter; Remark:9622 |
Procedure Step
|
Published
|
10/11/2023 3:30 PM
|
9621 - Remove AC line filter |
Instruction
|
Published
|
10/11/2023 2:52 PM
|
9622 - Remove two M4 mounting screws and washers. Retain hardware. |
Remark
|
Published
|
10/11/2023 2:58 PM
|
3397 - 3395 - Label faulty component; Remark:3396 |
Procedure Step
|
Published
|
07/21/2024 6:59 AM
|
3395 - Label faulty component |
Instruction
|
Published
|
08/07/2021 11:07 AM
|
3396 - Use tag or tape. Include date of removal, description of failure symptoms, co... |
Remark
|
Published
|
08/09/2021 11:35 AM
|
9639 - 9623 - Install New AC Line Filter; Remark: |
Procedure Step
|
Published
|
10/11/2023 3:30 PM
|
9623 - Install New AC Line Filter |
Instruction
|
Published
|
10/11/2023 3:01 PM
|
9640 - 9624 - Mount new AC line filter; Remark:9625 |
Procedure Step
|
Published
|
10/11/2023 3:31 PM
|
7263 - Caution : Correct placement of connectors and wiring is critical to proper operation. |
Annotation
|
Published
|
04/24/2023 2:32 PM
|
9624 - Mount new AC line filter |
Instruction
|
Published
|
10/11/2023 3:01 PM
|
9625 - Reuse retained M4 screws and internal washers. Remember to mount the ground w... |
Remark
|
Published
|
10/11/2023 3:04 PM
|
9641 - 9626 - Reconnect AC line filter wiring; Remark:9627 |
Procedure Step
|
Published
|
10/11/2023 3:32 PM
|
9626 - Reconnect AC line filter wiring |
Instruction
|
Published
|
10/11/2023 3:07 PM
|
9627 - Make sure the load wire (+) is accross from the line wire (+). |
Remark
|
Published
|
10/11/2023 3:09 PM
|
7279 - 7249 - Return equipment to normal operating condition; Remark: |
Procedure Step
|
Published
|
04/27/2023 4:13 PM
|
7249 - Return equipment to normal operating condition |
Instruction
|
Published
|
04/08/2025 3:22 PM
|
9642 - 9628 - Power on AC circuit breaker; Remark:9629 |
Procedure Step
|
Published
|
10/11/2023 3:33 PM
|
9628 - Power on AC circuit breaker |
Instruction
|
Published
|
10/11/2023 3:12 PM
|
9629 - AC Circuit Breaker On |
Remark
|
Published
|
10/11/2023 3:16 PM
|
9643 - 9630 - Verify AC line filter voltage; Remark:9631 |
Procedure Step
|
Published
|
10/11/2023 3:33 PM
|
9630 - Verify AC line filter voltage |
Instruction
|
Published
|
10/11/2023 3:18 PM
|
9631 - Voltage should be present at both the input and output. 110-240 VAC will be p... |
Remark
|
Published
|
10/11/2023 3:21 PM
|
7280 - 7250 - Power on RPM; Remark:7251 |
Procedure Step
|
Published
|
04/27/2023 4:14 PM
|
7250 - Power on RPM |
Instruction
|
Published
|
05/01/2023 8:31 AM
|
7251 - Move LD-260 switch to ON position. The LED PWR ON |
Remark
|
Published
|
05/10/2023 3:14 PM
|
7281 - 7252 - Verify RPM start-up; Remark:7253 |
Procedure Step
|
Published
|
04/20/2025 3:26 PM
|
7252 - Verify RPM start-up |
Instruction
|
Published
|
04/27/2023 2:23 PM
|
7253 - RPM will perform a power on self-test (POST) and collect a background radiati... |
Remark
|
Published
|
05/10/2023 3:14 PM
|
7282 - 7254 - Confirm network connection; Remark:7255 |
Procedure Step
|
Published
|
04/27/2023 4:15 PM
|
7254 - Confirm network connection |
Instruction
|
Published
|
04/27/2023 2:22 PM
|
7255 - Contact operators to confirm communications have been reestablished between RPM ... |
Remark
|
Published
|
05/10/2023 3:15 PM
|
7283 - 7256 - Close and lock all RPM doors; Remark: |
Procedure Step
|
Published
|
09/01/2023 11:45 PM
|
7256 - Close and lock all RPM doors |
Instruction
|
Published
|
04/27/2023 2:21 PM
|
7842 - 7820 - Inform system operators upon completion of maintenance action; Remark: |
Procedure Step
|
Published
|
07/07/2023 11:15 PM
|
7820 - Inform system operators upon completion of maintenance action |
Instruction
|
Published
|
07/07/2023 10:02 PM
|
322 - 321 - Document maintenance actions; Remark: |
Procedure Step
|
Published
|
06/17/2021 9:49 AM
|
321 - Document maintenance actions |
Instruction
|
Published
|
04/21/2025 11:19 AM
|
2869 - 2585 - Document maintenance performed; Remark:2866 |
Procedure Step
|
Published
|
06/18/2021 5:58 PM
|
2585 - Document maintenance performed |
Instruction
|
Published
|
07/09/2021 12:15 PM
|
2866 - Record observations, times, and results for the maintenance report. |
Remark
|
Published
|
04/21/2025 11:39 AM
|
4706 - 4705 - Submit report; Remark:4864 |
Procedure Step
|
Published
|
06/29/2022 9:50 AM
|
4705 - Submit report |
Instruction
|
Published
|
06/29/2022 9:50 AM
|
4864 - As specified by management or contractual obligations. |
Remark
|
Published
|
07/28/2022 1:36 PM
|
Corrective Maintenance Procedure |
Document Type
|
Published
|
03/02/2020 3:32 PM
|
Upon failure of AC line filter |
Frequency
|
Published
|
10/11/2023 3:49 PM
|
Warning |
Annotation Type
|
Published
|
03/02/2020 3:25 PM
|
Note |
Annotation Type
|
Published
|
03/02/2020 3:25 PM
|
Caution |
Annotation Type
|
Published
|
03/02/2020 3:24 PM
|
Technician 2 |
Skill Level
|
Published
|
04/09/2020 1:17 AM
|
Technician 1 |
Skill Level
|
Published
|
05/14/2020 2:56 PM
|
Small Phillips (PH1) screwdriver |
Tools
|
Published
|
05/14/2020 2:48 PM
|
Small slotted (flathead) screwdriver |
Tools
|
Published
|
09/11/2020 11:23 AM
|
Digital multimeter DMM |
Replacement Parts
|
Published
|
06/29/2023 5:46 PM
|
Orange/yellow safety vest |
Replacement Parts
|
Published
|
04/27/2023 6:56 PM
|
Safety shoes |
Replacement Parts
|
Published
|
04/27/2023 6:56 PM
|
Safety glasses if required |
Replacement Parts
|
Published
|
06/20/2023 4:47 PM
|
Ladder; 2 meters, 6 feet tall; non-conducting if required |
Replacement Parts
|
Published
|
07/02/2023 4:48 PM
|
Orange traffic cones |
Replacement Parts
|
Published
|
04/27/2023 6:56 PM
|
AC Line Ground Wire |
Image
|
Published
|
10/11/2023 2:33 PM
|
AC Line Filter Black Wire |
Image
|
Published
|
10/11/2023 2:42 PM
|
AC White Line Filter |
Image
|
Published
|
10/11/2023 2:48 PM
|
AC Line Filter Mounts |
Image
|
Published
|
10/11/2023 2:57 PM
|
AC Line Filter Wiring Orientation |
Image
|
Published
|
10/11/2023 3:08 PM
|
AC Breaker On |
Image
|
Published
|
10/11/2023 3:12 PM
|
AC Circuit Breaker On |
Image
|
Published
|
10/11/2023 3:15 PM
|
Measure AC Line Filter Voltage |
Image
|
Published
|
10/11/2023 3:17 PM
|
LD-260 Disconnect Switch Power On |
Image
|
Published
|
05/04/2023 3:37 PM
|