ID Title Content type Referenced in Step Referenced in Document Published
8519 8519 - Use a large Phillips (PH3) screwdriver. There should be four (4) screws, but ... Remark 8563 - 8518 - Remove four (4) front panel screws; Remark:8519 STEP: 8563 - 8518 - Remove four (4) front panel screws; Remark:8519
RPM Neutron Detector Helium-3 (He3) Tube Replacement
8520 8520 - Remove stabilizing brace screws Instruction 8565 - 8520 - Remove stabilizing brace screws; Remark:8521
9602 - 8520 - Remove stabilizing brace screws; Remark:8521
STEP: 8565 - 8520 - Remove stabilizing brace screws; Remark:8521
RPM Neutron Detector Helium-3 (He3) Tube Replacement
8521 8521 - There should be two stabilizing braces for each He3 tube; configurations migh... Remark 8565 - 8520 - Remove stabilizing brace screws; Remark:8521
9602 - 8520 - Remove stabilizing brace screws; Remark:8521
STEP: 8565 - 8520 - Remove stabilizing brace screws; Remark:8521
RPM Neutron Detector Helium-3 (He3) Tube Replacement
8522 8522 - Caution : Tube may fall out of detector assembly when bracket screw is removed. Annotation 8566 - 8523 - Loosen bracket screw (if applicable); Remark:8525 STEP: 8566 - 8523 - Loosen bracket screw (if applicable); Remark:8525
RPM Neutron Detector Helium-3 (He3) Tube Replacement
8523 8523 - Loosen bracket screw (if applicable) Instruction 8566 - 8523 - Loosen bracket screw (if applicable); Remark:8525 STEP: 8566 - 8523 - Loosen bracket screw (if applicable); Remark:8525
RPM Neutron Detector Helium-3 (He3) Tube Replacement
8524 8524 - Note : This step is only needed if replacing He3 tube from upper detector. Annotation
8525 8525 - If there is more than one screw, completely remove one. Use medium Phillips (... Remark 8566 - 8523 - Loosen bracket screw (if applicable); Remark:8525 STEP: 8566 - 8523 - Loosen bracket screw (if applicable); Remark:8525
RPM Neutron Detector Helium-3 (He3) Tube Replacement
8526 8526 - Rotate bracket (if applicable) Instruction 8567 - 8526 - Rotate bracket (if applicable); Remark:8527
8574 - 8526 - Rotate bracket (if applicable); Remark:8536
STEP: 8567 - 8526 - Rotate bracket (if applicable); Remark:8527
RPM Neutron Detector Helium-3 (He3) Tube Replacement

STEP: 8574 - 8526 - Rotate bracket (if applicable); Remark:8536
RPM Neutron Detector Helium-3 (He3) Tube Replacement
8527 8527 - Rotate neutron bracket Remark 8567 - 8526 - Rotate bracket (if applicable); Remark:8527 STEP: 8567 - 8526 - Rotate bracket (if applicable); Remark:8527
RPM Neutron Detector Helium-3 (He3) Tube Replacement
8528 8528 - Remove He3 tube Instruction 8568 - 8528 - Remove He3 tube; Remark:8529 STEP: 8568 - 8528 - Remove He3 tube; Remark:8529
RPM Neutron Detector Helium-3 (He3) Tube Replacement
8529 8529 - Slide tube up through hole and then pull out of moderator. Remark 8568 - 8528 - Remove He3 tube; Remark:8529 STEP: 8568 - 8528 - Remove He3 tube; Remark:8529
RPM Neutron Detector Helium-3 (He3) Tube Replacement
8530 8530 - Remove stabilizing braces Instruction 8569 - 8530 - Remove stabilizing braces; Remark:8531 STEP: 8569 - 8530 - Remove stabilizing braces; Remark:8531
RPM Neutron Detector Helium-3 (He3) Tube Replacement
8531 8531 - Slide stabilizing braces off He3 tube. Remark 8569 - 8530 - Remove stabilizing braces; Remark:8531 STEP: 8569 - 8530 - Remove stabilizing braces; Remark:8531
RPM Neutron Detector Helium-3 (He3) Tube Replacement
8532 8532 - Warning : Do not dispose of He3 neutron tube Annotation 8570 - 5395 - Label faulty component; Remark:7244
8533 8533 - Install New He3 Tube Instruction 8571 - 8533 - Install New He3 Tube; Remark: STEP: 8571 - 8533 - Install New He3 Tube; Remark:
RPM Neutron Detector Helium-3 (He3) Tube Replacement
8534 8534 - Place stabilizing braces onto new He3 tube Instruction 8572 - 8534 - Place stabilizing braces onto new He3 tube; Remark: STEP: 8572 - 8534 - Place stabilizing braces onto new He3 tube; Remark:
RPM Neutron Detector Helium-3 (He3) Tube Replacement
8535 8535 - Insert new He3 tube into moderator Instruction 8573 - 8535 - Insert new He3 tube into moderator; Remark: STEP: 8573 - 8535 - Insert new He3 tube into moderator; Remark:
RPM Neutron Detector Helium-3 (He3) Tube Replacement
8536 8536 - Rotate He3 tube bracket Remark 8574 - 8526 - Rotate bracket (if applicable); Remark:8536 STEP: 8574 - 8526 - Rotate bracket (if applicable); Remark:8536
RPM Neutron Detector Helium-3 (He3) Tube Replacement
8537 8537 - Tighten bracket screw (if applicable) Instruction 8575 - 8537 - Tighten bracket screw (if applicable); Remark:8538 STEP: 8575 - 8537 - Tighten bracket screw (if applicable); Remark:8538
RPM Neutron Detector Helium-3 (He3) Tube Replacement
8538 8538 - Use medium Phillips (PH2) screwdriver. Remark 8575 - 8537 - Tighten bracket screw (if applicable); Remark:8538 STEP: 8575 - 8537 - Tighten bracket screw (if applicable); Remark:8538
RPM Neutron Detector Helium-3 (He3) Tube Replacement
8539 8539 - Reinstall stabilizing braces screws Instruction 8576 - 8539 - Reinstall stabilizing braces screws; Remark:8540 STEP: 8576 - 8539 - Reinstall stabilizing braces screws; Remark:8540
RPM Neutron Detector Helium-3 (He3) Tube Replacement
8540 8540 - Use medium Phillips (PH2) screwdriver. Remark 8576 - 8539 - Reinstall stabilizing braces screws; Remark:8540 STEP: 8576 - 8539 - Reinstall stabilizing braces screws; Remark:8540
RPM Neutron Detector Helium-3 (He3) Tube Replacement
8541 8541 - Reinstall front panel with four (4) screws Instruction 8577 - 8541 - Reinstall front panel with four (4) screws; Remark:8542 STEP: 8577 - 8541 - Reinstall front panel with four (4) screws; Remark:8542
RPM Neutron Detector Helium-3 (He3) Tube Replacement
8542 8542 - Use large Phillips (PH3) screwdriver. Remark 8577 - 8541 - Reinstall front panel with four (4) screws; Remark:8542 STEP: 8577 - 8541 - Reinstall front panel with four (4) screws; Remark:8542
RPM Neutron Detector Helium-3 (He3) Tube Replacement
8543 8543 - Reconnect cable to He3 tube Instruction 8578 - 8543 - Reconnect cable to He3 tube; Remark:8544 STEP: 8578 - 8543 - Reconnect cable to He3 tube; Remark:8544
RPM Neutron Detector Helium-3 (He3) Tube Replacement
8544 8544 - Rotate to align connector notches. Push toward connection and turn coupling n... Remark 8578 - 8543 - Reconnect cable to He3 tube; Remark:8544 STEP: 8578 - 8543 - Reconnect cable to He3 tube; Remark:8544
RPM Neutron Detector Helium-3 (He3) Tube Replacement
8545 8545 - Isolate new He3 tube Instruction 8579 - 8545 - Isolate new He3 tube; Remark:8547 STEP: 8579 - 8545 - Isolate new He3 tube; Remark:8547
RPM Neutron Detector Helium-3 (He3) Tube Replacement
8546 8546 - Caution : Do not disconnect cable from new tube Annotation 8579 - 8545 - Isolate new He3 tube; Remark:8547 STEP: 8579 - 8545 - Isolate new He3 tube; Remark:8547
RPM Neutron Detector Helium-3 (He3) Tube Replacement
8547 8547 - Disconnect cables from all He3 tubes in moderator (white box) except Remark 8579 - 8545 - Isolate new He3 tube; Remark:8547 STEP: 8579 - 8545 - Isolate new He3 tube; Remark:8547
RPM Neutron Detector Helium-3 (He3) Tube Replacement
8548 8548 - Navigate to SHOW COUNTS for neutron channels Instruction 8580 - 8548 - Navigate to SHOW COUNTS for neutron channels; Remark:8549 STEP: 8580 - 8548 - Navigate to SHOW COUNTS for neutron channels; Remark:8549
RPM Neutron Detector Helium-3 (He3) Tube Replacement
RPM HHV-448/458 High Voltage Board Replacement
8549 8549 - On SC-770, press 01234# Then, press 2: Remark 8580 - 8548 - Navigate to SHOW COUNTS for neutron channels; Remark:8549 STEP: 8580 - 8548 - Navigate to SHOW COUNTS for neutron channels; Remark:8549
RPM Neutron Detector Helium-3 (He3) Tube Replacement
RPM HHV-448/458 High Voltage Board Replacement
8550 8550 - Place neutron source on neutron detector Instruction 8581 - 8550 - Place neutron source on neutron detector; Remark:8551 STEP: 8581 - 8550 - Place neutron source on neutron detector; Remark:8551
RPM Neutron Detector Helium-3 (He3) Tube Replacement
8551 8551 - Secure source to middle of detector with adhesive tape. Remark 8581 - 8550 - Place neutron source on neutron detector; Remark:8551 STEP: 8581 - 8550 - Place neutron source on neutron detector; Remark:8551
RPM Neutron Detector Helium-3 (He3) Tube Replacement
8552 8552 - Verify counts from new He3 tube Instruction
8553 8553 - Neutron counts will increase on the channel with the new He3 tube Remark 8582 - 9606 - Verify counts from cleaned He3 tube; Remark:8553 STEP: 8582 - 9606 - Verify counts from cleaned He3 tube; Remark:8553
RPM Neutron Detector Helium-3 (He3) Tube Replacement
8554 8554 - On SC-770, press # button until main controller screen is di... Remark 8584 - 8458 - Exit programming mode; Remark:8554 STEP: 8584 - 8458 - Exit programming mode; Remark:8554
RPM SC-770 Controller Module Replacement
RPM Neutron Detector Helium-3 (He3) Tube Replacement
RPM VD-580 Replacement
RPM SC-770 Rabbit Board Firmware Update
8555 8555 - Reconnect all neutron detectors Instruction 8585 - 8555 - Reconnect all neutron detectors; Remark:8556 STEP: 8585 - 8555 - Reconnect all neutron detectors; Remark:8556
RPM Neutron Detector Helium-3 (He3) Tube Replacement
8556 8556 - Connecting neutron cable Remark 8585 - 8555 - Reconnect all neutron detectors; Remark:8556 STEP: 8585 - 8555 - Reconnect all neutron detectors; Remark:8556
RPM Neutron Detector Helium-3 (He3) Tube Replacement
8557 8557 - Perform functional compliance test Instruction 8586 - 8557 - Perform functional compliance test; Remark:8558 STEP: 8586 - 8557 - Perform functional compliance test; Remark:8558
RPM Neutron Detector Helium-3 (He3) Tube Replacement
8558 8558 - DET-RPM-RAP-RM05, RPM Functional Compliance Test. Remark 8586 - 8557 - Perform functional compliance test; Remark:8558 STEP: 8586 - 8557 - Perform functional compliance test; Remark:8558
RPM Neutron Detector Helium-3 (He3) Tube Replacement
8559 8559 - To reconnect sensor cable, align connectors, push towards sensor, and turn co... Remark 8587 - 7305 - Enable both infrared occupancy sensors; Remark:8559
8588 - 7305 - Enable both infrared occupancy sensors; Remark:8559
8647 - 8661 - Reconnect applicable cable previously removed in Step 4-4; Remark:8559
STEP: 8587 - 7305 - Enable both infrared occupancy sensors; Remark:8559
RPM LD-260 Load Disconnect Replacement
RPM Ethernet-to-Fiber Media Converter Replacement
RPM IXIO-DT1 Occupancy Sensor Replacement
RPM SCA-774 Single Channel Analyzer Board Replacement
RPM SCA-775 Module Replacement
RPM LD-260 Load Disconnect Fuse Replacement
RPM SC-771 Controller Board Replacement
RPM SC-770 Controller Module Replacement
RPM Banner IR Occupancy Sensor Replacement
RPM Nano Controller Replacement
RPM SPY-2 to IXIO-DT1 Occupancy Sensor Conversion
RPM Neutron Signal Pick-Off Box (PMFX) Replacement
RPM VD-580 Replacement

STEP: 8588 - 7305 - Enable both infrared occupancy sensors; Remark:8559
RPM Neutron Detector Helium-3 (He3) Tube Replacement
RPM RS232 to RS485 Converter Replacement
8560 8560 - 8518 - Remove four (4) front panel screws; Remark: Procedure Step
8561 8561 - 7291 - Disable both infrared occupancy sensors; Remark:8514 Procedure Step
8562 8562 - 8516 - Disconnect cable from faulty helium-3 (He3) tube; Remark:8517 Procedure Step
8563 8563 - 8518 - Remove four (4) front panel screws; Remark:8519 Procedure Step
8564 8564 - 6748 - Remove front panel; Remark: Procedure Step
8565 8565 - 8520 - Remove stabilizing brace screws; Remark:8521 Procedure Step
8566 8566 - 8523 - Loosen bracket screw (if applicable); Remark:8525 Procedure Step
8567 8567 - 8526 - Rotate bracket (if applicable); Remark:8527 Procedure Step
8568 8568 - 8528 - Remove He3 tube; Remark:8529 Procedure Step
8569 8569 - 8530 - Remove stabilizing braces; Remark:8531 Procedure Step
8571 8571 - 8533 - Install New He3 Tube; Remark: Procedure Step
8572 8572 - 8534 - Place stabilizing braces onto new He3 tube; Remark: Procedure Step
8573 8573 - 8535 - Insert new He3 tube into moderator; Remark: Procedure Step
8574 8574 - 8526 - Rotate bracket (if applicable); Remark:8536 Procedure Step
8575 8575 - 8537 - Tighten bracket screw (if applicable); Remark:8538 Procedure Step
8576 8576 - 8539 - Reinstall stabilizing braces screws; Remark:8540 Procedure Step
8577 8577 - 8541 - Reinstall front panel with four (4) screws; Remark:8542 Procedure Step
8578 8578 - 8543 - Reconnect cable to He3 tube; Remark:8544 Procedure Step
8579 8579 - 8545 - Isolate new He3 tube; Remark:8547 Procedure Step
8580 8580 - 8548 - Navigate to SHOW COUNTS for neutron channels; Remark:8549 Procedure Step
8581 8581 - 8550 - Place neutron source on neutron detector; Remark:8551 Procedure Step
8582 8582 - 9606 - Verify counts from cleaned He3 tube; Remark:8553 Procedure Step
8583 8583 - 2581 - Remove radioactive source; Remark: Procedure Step
8584 8584 - 8458 - Exit programming mode; Remark:8554 Procedure Step
8585 8585 - 8555 - Reconnect all neutron detectors; Remark:8556 Procedure Step
8586 8586 - 8557 - Perform functional compliance test; Remark:8558 Procedure Step
8587 8587 - 7305 - Enable both infrared occupancy sensors; Remark:8559 Procedure Step
8588 8588 - 7305 - Enable both infrared occupancy sensors; Remark:8559 Procedure Step
8589 8589 - 7310 - Enable tamper switches; Remark:7348 Procedure Step
8591 8591 - 8515 - Uninstall Faulty Neutron Tube; Remark: Procedure Step
8592 8592 - Uninstall faulty RS232 to RS485 converter Instruction 8600 - 8592 - Uninstall faulty RS232 to RS485 converter; Remark: STEP: 8600 - 8592 - Uninstall faulty RS232 to RS485 converter; Remark:
RPM RS232 to RS485 Converter Replacement
8593 8593 - Remove faulty RS232 to RS485 converter Instruction 8605 - 8593 - Remove faulty RS232 to RS485 converter; Remark: STEP: 8605 - 8593 - Remove faulty RS232 to RS485 converter; Remark:
RPM RS232 to RS485 Converter Replacement
8594 8594 - Install new RS232 to RS485 Converter Instruction 8601 - 8594 - Install new RS232 to RS485 Converter; Remark: STEP: 8601 - 8594 - Install new RS232 to RS485 Converter; Remark:
RPM RS232 to RS485 Converter Replacement
8595 8595 - Mount new RS232 to RS485 converter Instruction 8602 - 8595 - Mount new RS232 to RS485 converter; Remark:8596 STEP: 8602 - 8595 - Mount new RS232 to RS485 converter; Remark:8596
RPM RS232 to RS485 Converter Replacement
8596 8596 - Use retained hardware. Remark 8602 - 8595 - Mount new RS232 to RS485 converter; Remark:8596 STEP: 8602 - 8595 - Mount new RS232 to RS485 converter; Remark:8596
RPM RS232 to RS485 Converter Replacement
8597 8597 - Connect power/signal connector and RJ-45 Ethernet cable. Remark 8603 - 2757 - Reconnect wiring; Remark:8597 STEP: 8603 - 2757 - Reconnect wiring; Remark:8597
RPM RS232 to RS485 Converter Replacement
8598 8598 - Reinstall LD-260 (VM-250 only) Instruction 8604 - 8598 - Reinstall LD-260 (VM-250 only); Remark: STEP: 8604 - 8598 - Reinstall LD-260 (VM-250 only); Remark:
RPM RS232 to RS485 Converter Replacement
8599 8599 - Nano Controller LEDs will illuminate (IN1, IN2 Remark 8606 - 7308 - Verify Nano Controller response; Remark:8599 STEP: 8606 - 7308 - Verify Nano Controller response; Remark:8599
RPM RS232 to RS485 Converter Replacement
RPM Nano Controller Replacement
8600 8600 - 8592 - Uninstall faulty RS232 to RS485 converter; Remark: Procedure Step
8601 8601 - 8594 - Install new RS232 to RS485 Converter; Remark: Procedure Step
8602 8602 - 8595 - Mount new RS232 to RS485 converter; Remark:8596 Procedure Step
8603 8603 - 2757 - Reconnect wiring; Remark:8597 Procedure Step
8604 8604 - 8598 - Reinstall LD-260 (VM-250 only); Remark: Procedure Step
8605 8605 - 8593 - Remove faulty RS232 to RS485 converter; Remark: Procedure Step
8606 8606 - 7308 - Verify Nano Controller response; Remark:8599 Procedure Step
8613 8613 - Uninstall Faulty Sensor Instruction 8623 - 8613 - Uninstall Faulty Sensor; Remark: STEP: 8623 - 8613 - Uninstall Faulty Sensor; Remark:
RPM Banner IR Occupancy Sensor Replacement
8614 8614 - Locate infrared sensors Instruction 8624 - 8614 - Locate infrared sensors; Remark:8615 STEP: 8624 - 8614 - Locate infrared sensors; Remark:8615
RPM Banner IR Occupancy Sensor Replacement
8615 8615 - Typical sensor locations are as follows: Control pillar hou... Remark 8624 - 8614 - Locate infrared sensors; Remark:8615 STEP: 8624 - 8614 - Locate infrared sensors; Remark:8615
RPM Banner IR Occupancy Sensor Replacement
8616 8616 - Note : It is unlikely for an emitter and receiver to fail at the same time. Most lik... Annotation
8617 8617 - Disconnect applicable infrared sensors Instruction 8625 - 8617 - Disconnect applicable infrared sensors; Remark:8618 STEP: 8625 - 8617 - Disconnect applicable infrared sensors; Remark:8618
RPM Banner IR Occupancy Sensor Replacement
8618 8618 - To disconnect sensor cable, turn collar counterclockwise and pull away from s... Remark 8625 - 8617 - Disconnect applicable infrared sensors; Remark:8618 STEP: 8625 - 8617 - Disconnect applicable infrared sensors; Remark:8618
RPM Banner IR Occupancy Sensor Replacement
8619 8619 - Unscrew mounting nut Instruction 8626 - 8619 - Unscrew mounting nut; Remark:8620 STEP: 8626 - 8619 - Unscrew mounting nut; Remark:8620
RPM Banner IR Occupancy Sensor Replacement
8620 8620 - Rotate threaded nut counterclockwise. It may be necessary to hold the infrare... Remark 8626 - 8619 - Unscrew mounting nut; Remark:8620 STEP: 8626 - 8619 - Unscrew mounting nut; Remark:8620
RPM Banner IR Occupancy Sensor Replacement
8621 8621 - Remove sensor from back of door Instruction 8627 - 8621 - Remove sensor from back of door; Remark:8622 STEP: 8627 - 8621 - Remove sensor from back of door; Remark:8622
RPM Banner IR Occupancy Sensor Replacement
8622 8622 - Removal of infrared sensor Remark 8627 - 8621 - Remove sensor from back of door; Remark:8622 STEP: 8627 - 8621 - Remove sensor from back of door; Remark:8622
RPM Banner IR Occupancy Sensor Replacement
8623 8623 - 8613 - Uninstall Faulty Sensor; Remark: Procedure Step
8624 8624 - 8614 - Locate infrared sensors; Remark:8615 Procedure Step
8625 8625 - 8617 - Disconnect applicable infrared sensors; Remark:8618 Procedure Step
8626 8626 - 8619 - Unscrew mounting nut; Remark:8620 Procedure Step