2523 |
2523 - 2522 - Tap slider next to Nuclide library; Remark:2521 |
Procedure Step |
|
|
✔ |
2524 |
2524 - Scroll through folder to locate file |
Remark |
2526 - 2525 - Tap on new library file; Remark:2524 |
STEP: 2526 - 2525 - Tap on new library file; Remark:2524 AT6101C Library Update Android |
✔ |
2525 |
2525 - Tap on new library file |
Instruction |
2526 - 2525 - Tap on new library file; Remark:2524 |
STEP: 2526 - 2525 - Tap on new library file; Remark:2524 AT6101C Library Update Android |
✔ |
2526 |
2526 - 2525 - Tap on new library file; Remark:2524 |
Procedure Step |
|
|
✔ |
2527 |
2527 - Verify new library file is selected |
Remark |
2529 - 2528 - Verify new library file is selected; Remark:2527 |
STEP: 2529 - 2528 - Verify new library file is selected; Remark:2527 AT6101C Library Update Android |
✔ |
2528 |
2528 - Verify new library file is selected |
Instruction |
2529 - 2528 - Verify new library file is selected; Remark:2527 |
STEP: 2529 - 2528 - Verify new library file is selected; Remark:2527 AT6101C Library Update Android |
✔ |
2529 |
2529 - 2528 - Verify new library file is selected; Remark:2527 |
Procedure Step |
|
|
✔ |
2530 |
2530 - Restart Atomtex App |
Instruction |
1635 - 2530 - Restart Atomtex App; Remark: |
STEP: 1635 - 2530 - Restart Atomtex App; Remark: AT6101C Library Update Android |
✔ |
2531 |
2531 - Tap the back button on the device until the main screen appears |
Remark |
|
|
✔ |
2534 |
2534 - Tap menu icon, then Exit |
Remark |
|
|
✔ |
2537 |
2537 - Atomtex App Icon |
Remark |
2539 - 1427 - Start Atomtex App; Remark:2537 |
STEP: 2539 - 1427 - Start Atomtex App; Remark:2537 AT6101C Library Update Android |
✔ |
2539 |
2539 - 1427 - Start Atomtex App; Remark:2537 |
Procedure Step |
|
|
✔ |
2541 |
2541 - 1634 - Verify system is operating correctly; Remark:1633 |
Procedure Step |
|
|
✔ |
2543 |
2543 - IO PRM-470 Screen SEARCH mode Gamma 278 CPS |
Remark |
2720 - 2719 - Determine Average CPS of source and background radiation; Remark:2543 |
STEP: 2720 - 2719 - Determine Average CPS of source and background radiation; Remark:2543 PRM-470 Efficiency Test |
✔ |
2544 |
2544 - IO PRM-470 Screen BACKGROUND mode 60 CPS |
Remark |
2706 - 2705 - Verify instrument is in BACKGROUND MODE; Remark:2544 |
STEP: 2706 - 2705 - Verify instrument is in BACKGROUND MODE; Remark:2544 PRM-470 Efficiency Test |
✔ |
2545 |
2545 - IO PRM-470 Power Button Red Box |
Remark |
139 - 220 - Power on instrument; Remark:2545 2633 - 220 - Power on instrument; Remark:2545 3090 - 313 - Power off instrument; Remark:2545 |
STEP: 139 - 220 - Power on instrument; Remark:2545 PRM-470 CG Survey Instrument
STEP: 2633 - 220 - Power on instrument; Remark:2545 PRM-470 Gamma Alignment PRM-470 Efficiency Test
STEP: 3090 - 313 - Power off instrument; Remark:2545 PRM-470 CG Survey Instrument |
✔ |
2546 |
2546 - IO PRM-470 Front View Upright |
Remark |
2697 - 2696 - Position instrument upright; Remark:3458 |
STEP: 2697 - 2696 - Position instrument upright; Remark:3458 PRM-470 Efficiency Test |
✔ |
2547 |
2547 - IO PRM-470 Remove Charger Cable |
Remark |
2548 - 205 - Disconnect charger; Remark:2547 |
STEP: 2548 - 205 - Disconnect charger; Remark:2547 PRM-470 Gamma Alignment PRM-470 NHA-472 Board Replacement PRM-470 Efficiency Test |
✔ |
2548 |
2548 - 205 - Disconnect charger; Remark:2547 |
Procedure Step |
|
|
✔ |
2551 |
2551 - Connect Multichannel Analyzer (MCA) |
Instruction |
2643 - 2551 - Connect Multichannel Analyzer (MCA); Remark: |
STEP: 2643 - 2551 - Connect Multichannel Analyzer (MCA); Remark: PRM-470 Gamma Alignment |
✔ |
2552 |
2552 - Connect MCA to computer |
Instruction |
2644 - 2552 - Connect MCA to computer; Remark:2630 |
STEP: 2644 - 2552 - Connect MCA to computer; Remark:2630 PRM-470 Gamma Alignment |
✔ |
2553 |
2553 - Attach test leads to MCA |
Instruction |
2645 - 2553 - Attach test leads to MCA; Remark:2629 |
STEP: 2645 - 2553 - Attach test leads to MCA; Remark:2629 PRM-470 Gamma Alignment |
✔ |
2554 |
2554 - Collect pre-alignment Spectra |
Instruction |
2646 - 2554 - Collect pre-alignment Spectra; Remark: |
STEP: 2646 - 2554 - Collect pre-alignment Spectra; Remark: PRM-470 Gamma Alignment |
✔ |
2555 |
2555 - Start Amptek software |
Instruction |
2647 - 2555 - Start Amptek software; Remark:2627 |
STEP: 2647 - 2555 - Start Amptek software; Remark:2627 PRM-470 Gamma Alignment |
✔ |
2556 |
2556 - Verify MCA settings |
Instruction |
2648 - 2556 - Verify MCA settings; Remark:2626 |
STEP: 2648 - 2556 - Verify MCA settings; Remark:2626 PRM-470 Gamma Alignment |
✔ |
2557 |
2557 - Place Cs-137 source on gamma detector |
Instruction |
2649 - 2557 - Place Cs-137 source on gamma detector; Remark:2625 |
STEP: 2649 - 2557 - Place Cs-137 source on gamma detector; Remark:2625 PRM-470 Gamma Alignment |
✔ |
2558 |
2558 - Connect leads to stage 1 test points |
Instruction |
2650 - 2558 - Connect leads to stage 1 test points; Remark:2624 |
STEP: 2650 - 2558 - Connect leads to stage 1 test points; Remark:2624 PRM-470 Gamma Alignment |
✔ |
2559 |
2559 - Collect stage 1 spectrum |
Instruction |
2651 - 2559 - Collect stage 1 spectrum; Remark:2622 2669 - 2559 - Collect stage 1 spectrum; Remark:2598 |
STEP: 2651 - 2559 - Collect stage 1 spectrum; Remark:2622 PRM-470 Gamma Alignment
STEP: 2669 - 2559 - Collect stage 1 spectrum; Remark:2598 PRM-470 Gamma Alignment |
✔ |
2560 |
2560 - Save stage 1 spectrum |
Instruction |
2652 - 2560 - Save stage 1 spectrum; Remark:2620 2670 - 2560 - Save stage 1 spectrum; Remark:2597 |
STEP: 2652 - 2560 - Save stage 1 spectrum; Remark:2620 PRM-470 Gamma Alignment
STEP: 2670 - 2560 - Save stage 1 spectrum; Remark:2597 PRM-470 Gamma Alignment |
✔ |
2561 |
2561 - Connect leads to stage 2 test point |
Instruction |
2653 - 2561 - Connect leads to stage 2 test point; Remark:2619 |
STEP: 2653 - 2561 - Connect leads to stage 2 test point; Remark:2619 PRM-470 Gamma Alignment |
✔ |
2562 |
2562 - Collect stage 2 spectrum |
Instruction |
2654 - 2562 - Collect stage 2 spectrum; Remark:2617 2673 - 2562 - Collect stage 2 spectrum; Remark:2592 |
STEP: 2654 - 2562 - Collect stage 2 spectrum; Remark:2617 PRM-470 Gamma Alignment
STEP: 2673 - 2562 - Collect stage 2 spectrum; Remark:2592 PRM-470 Gamma Alignment |
✔ |
2563 |
2563 - Save stage 2 spectrum |
Instruction |
2655 - 2563 - Save stage 2 spectrum; Remark:2616 2674 - 2563 - Save stage 2 spectrum; Remark:2591 |
STEP: 2655 - 2563 - Save stage 2 spectrum; Remark:2616 PRM-470 Gamma Alignment
STEP: 2674 - 2563 - Save stage 2 spectrum; Remark:2591 PRM-470 Gamma Alignment |
✔ |
2564 |
2564 - Measure pre-alignment high voltage |
Instruction |
2656 - 2564 - Measure pre-alignment high voltage; Remark: |
STEP: 2656 - 2564 - Measure pre-alignment high voltage; Remark: PRM-470 Gamma Alignment |
✔ |
2565 |
2565 - Connect HV probe to DMM |
Instruction |
2657 - 2565 - Connect HV probe to DMM; Remark:2614 |
STEP: 2657 - 2565 - Connect HV probe to DMM; Remark:2614 PRM-470 Gamma Alignment |
✔ |
2566 |
2566 - Switch DMM to DC voltage |
Instruction |
2658 - 2566 - Switch DMM to DC voltage; Remark:2613 |
STEP: 2658 - 2566 - Switch DMM to DC voltage; Remark:2613 PRM-470 Gamma Alignment PRM-470 NHA-472 Board Replacement |
✔ |
2567 |
2567 - Locate ground test point |
Instruction |
2659 - 2567 - Locate ground test point; Remark:2610 2785 - 2567 - Locate ground test point; Remark:2782 |
STEP: 2659 - 2567 - Locate ground test point; Remark:2610 PRM-470 Gamma Alignment
STEP: 2785 - 2567 - Locate ground test point; Remark:2782 PRM-470 NHA-472 Board Replacement |
✔ |
2568 |
2568 - Connect HV probe to ground |
Instruction |
2660 - 2568 - Connect HV probe to ground; Remark:2609 |
STEP: 2660 - 2568 - Connect HV probe to ground; Remark:2609 PRM-470 Gamma Alignment |
✔ |
2569 |
2569 - Locate HV test point |
Instruction |
2661 - 2569 - Locate HV test point; Remark:2607 |
STEP: 2661 - 2569 - Locate HV test point; Remark:2607 PRM-470 Gamma Alignment |
✔ |
2570 |
2570 - Connect HV probe to test point |
Instruction |
2662 - 2570 - Connect HV probe to test point; Remark:2605 |
STEP: 2662 - 2570 - Connect HV probe to test point; Remark:2605 PRM-470 Gamma Alignment |
✔ |
2571 |
2571 - Document voltage |
Instruction |
2663 - 2571 - Document voltage; Remark:2589 2680 - 2571 - Document voltage; Remark:2589 |
STEP: 2663 - 2571 - Document voltage; Remark:2589 PRM-470 Gamma Alignment
STEP: 2680 - 2571 - Document voltage; Remark:2589 PRM-470 Gamma Alignment |
✔ |
2572 |
2572 - Remove HV probe from PRM-470 |
Instruction |
2664 - 2572 - Remove HV probe from PRM-470; Remark: 2681 - 2572 - Remove HV probe from PRM-470; Remark:2588 |
STEP: 2664 - 2572 - Remove HV probe from PRM-470; Remark: PRM-470 Gamma Alignment
STEP: 2681 - 2572 - Remove HV probe from PRM-470; Remark:2588 PRM-470 Gamma Alignment |
✔ |
2573 |
2573 - Adjust gains |
Instruction |
2665 - 2573 - Adjust gains; Remark: |
STEP: 2665 - 2573 - Adjust gains; Remark: PRM-470 Gamma Alignment |
✔ |
2574 |
2574 - Connect leads to stage 1 test points |
Instruction |
2666 - 2574 - Connect leads to stage 1 test points; Remark:2602 |
STEP: 2666 - 2574 - Connect leads to stage 1 test points; Remark:2602 PRM-470 Gamma Alignment |
✔ |
2575 |
2575 - Verify Cs-137 source is on center of gamma detector |
Instruction |
2667 - 2575 - Verify Cs-137 source is on center of gamma detector; Remark:2601 |
STEP: 2667 - 2575 - Verify Cs-137 source is on center of gamma detector; Remark:2601 PRM-470 Gamma Alignment |
✔ |
2576 |
2576 - Adjust stage 1 gain |
Instruction |
2668 - 2576 - Adjust stage 1 gain; Remark:2599 |
STEP: 2668 - 2576 - Adjust stage 1 gain; Remark:2599 PRM-470 Gamma Alignment |
✔ |
2577 |
2577 - Connect to stage 2 test point |
Instruction |
2671 - 2577 - Connect to stage 2 test point; Remark:2596 |
STEP: 2671 - 2577 - Connect to stage 2 test point; Remark:2596 PRM-470 Gamma Alignment |
✔ |
2578 |
2578 - Adjust stage 2 gain |
Instruction |
2672 - 2578 - Adjust stage 2 gain; Remark:2593 |
STEP: 2672 - 2578 - Adjust stage 2 gain; Remark:2593 PRM-470 Gamma Alignment |
✔ |
2579 |
2579 - Remove test leads |
Instruction |
2675 - 2579 - Remove test leads; Remark: |
STEP: 2675 - 2579 - Remove test leads; Remark: PRM-470 Gamma Alignment |
✔ |
2580 |
2580 - Disconnect MCA |
Instruction |
2676 - 2580 - Disconnect MCA; Remark: |
STEP: 2676 - 2580 - Disconnect MCA; Remark: PRM-470 Gamma Alignment |
✔ |
2581 |
2581 - Remove radioactive source |
Instruction |
2677 - 2581 - Remove radioactive source; Remark: 8583 - 2581 - Remove radioactive source; Remark: |
STEP: 2677 - 2581 - Remove radioactive source; Remark: PRM-470 Gamma Alignment
STEP: 8583 - 2581 - Remove radioactive source; Remark: RPM Neutron Detector Helium-3 (He3) Tube Replacement |
✔ |
2582 |
2582 - Measure post-alignment high voltage |
Instruction |
2678 - 2582 - Measure post-alignment high voltage; Remark: |
STEP: 2678 - 2582 - Measure post-alignment high voltage; Remark: PRM-470 Gamma Alignment |
✔ |
2583 |
2583 - Measure high voltage |
Instruction |
2679 - 2583 - Measure high voltage; Remark:2590 |
STEP: 2679 - 2583 - Measure high voltage; Remark:2590 PRM-470 Gamma Alignment |
✔ |
2584 |
2584 - Perform efficiency test |
Instruction |
2682 - 2584 - Perform efficiency test; Remark:2587 6435 - 2584 - Perform efficiency test; Remark:6434 6896 - 2584 - Perform efficiency test; Remark:6895 |
STEP: 2682 - 2584 - Perform efficiency test; Remark:2587 PRM-470 Gamma Alignment
STEP: 6435 - 2584 - Perform efficiency test; Remark:6434 PackEye FHT 681 Replacement PackEye Gamma Detector Replacement
STEP: 6896 - 2584 - Perform efficiency test; Remark:6895 PackEye Routine Assessment |
✔ |
2585 |
2585 - Document maintenance performed |
Instruction |
2683 - 2585 - Document maintenance performed; Remark:8230 2869 - 2585 - Document maintenance performed; Remark:2866 5685 - 2585 - Document maintenance performed; Remark:5684 5793 - 2585 - Document maintenance performed; Remark:2866 5927 - 2585 - Document maintenance performed; Remark:2866 6334 - 2585 - Document maintenance performed; Remark:2866 6437 - 2585 - Document maintenance performed; Remark:2866 6547 - 2585 - Document maintenance performed; Remark:2866 6796 - 2585 - Document maintenance performed; Remark:2866 6892 - 2585 - Document maintenance performed; Remark:8230 |
STEP: 2869 - 2585 - Document maintenance performed; Remark:2866 PRM-470 Battery Replacement PRM-470 PRCB-472 Board Replacement PRM-470 Overlay Replacement PRM-470 Charging Port Replacement PRM-470 GHA-472 Board Replacement PRM-470 LCD Assembly Replacement AT6101C BT-DU3 Replacement AT6101C Gamma Detector Replacement AT6101C Neutron Detector Replacement AT6101C Routine Assessment AT6101C BTDU-3 Battery Replacement AT6101C Radionuclide Library Update Windows AT6101C Library Update Android PRM-470 Gamma Alignment PRM-470 NHA-472 Board Replacement Radiation Pager Battery Replacement Radiation Pager Adjust Threshold RadSeeker Internal Battery Replacement RadSeeker Check Connections RadSeeker CS/CL Wi-Fi Status Change PackEye Power Supply Replacement PackEye Reseat Power Supply Connections PackEye Refurbish Power Supply RadSeeker Calibration VeriFinder Stabilization Module Replacement PackEye Reseat FHT 681 Connections PackEye FHT 681 Replacement PackEye Firmware Update PackEye Gamma Detector Replacement PackEye Reseat Indicator Connections PackEye Neutron Detector Replacement PackEye Gamma High Voltage Adjustment RPM LD-260 Load Disconnect Replacement RPM Ethernet-to-Fiber Media Converter Replacement RPM IXIO-DT1 Occupancy Sensor Replacement RPM +12 VDC Battery Load Test RPM Functional Compliance Test RPM SCA-774 Single Channel Analyzer Board Replacement RPM SCA-775 Module Replacement RPM LD-260 Load Disconnect Fuse Replacement RPM Rabbit Board Replacement RPM Desiccant Inspection and Replacement RPM SC-771 Controller Board Replacement RPM Gamma Detector Replacement RPM ThetaController Installation RPM Sonalert Module Replacement RPM Neutron Detector Helium-3 (He3) Tube Replacement RPM RS232 to RS485 Converter Replacement RPM Banner IR Occupancy Sensor Replacement RPM SC-770 Controller Module Replacement RPM Alarm Strobe Light Assembly Replacement RPM ELK Siren Replacement RPM ELK Siren Driver Replacement RPM Nano Controller Replacement RPM SPY-2 to IXIO-DT1 Occupancy Sensor Conversion RPM Neutron Signal Pick-Off Box (PMFX) Replacement RPM VD-580 Replacement RPM Tamper Switch Alignment, Replacement, and Repair RPM LED Fault Light Assembly Replacement RPM SC-770 Rabbit Board Firmware Update RPM Neutron Detector Contaminant Removal RPM AC Line Filter Replacement RPM HHV-448/458 High Voltage Board Replacement RPM General Purpose Relay Board Replacement RPM +15Vdc Power Supply Replacement RPM AM-270 Remote Alarm Panel Replacement RPM +12 VDC Battery Replacement RPM Cabinet Door Gasket Replacement RadSeeker Stabilization Module Replacement TA600 Power Knob Adjustment TA600 Top Housing Replacement RPM Cleaning and Inspection
STEP: 6892 - 2585 - Document maintenance performed; Remark:8230 PackEye Routine Assessment |
✔ |
2586 |
2586 - Date, time, spare parts used, other conditions corrected at time of visit, an... |
Remark |
|
|
✔ |
2587 |
2587 - DET-HHD-RAP-RM05, PRM-470 Efficiency Test |
Remark |
2682 - 2584 - Perform efficiency test; Remark:2587 |
STEP: 2682 - 2584 - Perform efficiency test; Remark:2587 PRM-470 Gamma Alignment |
✔ |
2588 |
2588 - Power off DMM. Carefully remove test leads. |
Remark |
2681 - 2572 - Remove HV probe from PRM-470; Remark:2588 |
STEP: 2681 - 2572 - Remove HV probe from PRM-470; Remark:2588 PRM-470 Gamma Alignment |
✔ |
2589 |
2589 - The number indicated on the DMM must be multiplied by 1000 if the 80K-40 prob... |
Remark |
2663 - 2571 - Document voltage; Remark:2589 2680 - 2571 - Document voltage; Remark:2589 |
STEP: 2663 - 2571 - Document voltage; Remark:2589 PRM-470 Gamma Alignment
STEP: 2680 - 2571 - Document voltage; Remark:2589 PRM-470 Gamma Alignment |
✔ |
2590 |
2590 - Repeat high voltage measurement steps provided earlier in this procedure.... |
Remark |
2679 - 2583 - Measure high voltage; Remark:2590 |
STEP: 2679 - 2583 - Measure high voltage; Remark:2590 PRM-470 Gamma Alignment |
✔ |
2591 |
2591 - Use the correct file naming convention. Example: US_Richland_CG_102... |
Remark |
2674 - 2563 - Save stage 2 spectrum; Remark:2591 |
STEP: 2674 - 2563 - Save stage 2 spectrum; Remark:2591 PRM-470 Gamma Alignment |
✔ |
2592 |
2592 - Place the cursor at channel 310 to monitor the counts. |
Remark |
2673 - 2562 - Collect stage 2 spectrum; Remark:2592 |
STEP: 2673 - 2562 - Collect stage 2 spectrum; Remark:2592 PRM-470 Gamma Alignment |
✔ |
2593 |
2593 - Use Tweaker to adjust R17 (may not be labeled on board) until peak is centere... |
Remark |
2672 - 2578 - Adjust stage 2 gain; Remark:2593 |
STEP: 2672 - 2578 - Adjust stage 2 gain; Remark:2593 PRM-470 Gamma Alignment |
✔ |
2594 |
2594 - Determine current activity of radioactive source |
Instruction |
2595 - 2594 - Determine current activity of radioactive source; Remark: |
STEP: 2595 - 2594 - Determine current activity of radioactive source; Remark: PRM-470 Efficiency Test |
✔ |
2595 |
2595 - 2594 - Determine current activity of radioactive source; Remark: |
Procedure Step |
|
|
✔ |
2596 |
2596 - Move red test lead to TP2. |
Remark |
2671 - 2577 - Connect to stage 2 test point; Remark:2596 |
STEP: 2671 - 2577 - Connect to stage 2 test point; Remark:2596 PRM-470 Gamma Alignment |
✔ |
2597 |
2597 - Use the correct file naming convention. Example: US_Richland_CG_102... |
Remark |
2670 - 2560 - Save stage 1 spectrum; Remark:2597 |
STEP: 2670 - 2560 - Save stage 1 spectrum; Remark:2597 PRM-470 Gamma Alignment |
✔ |
2598 |
2598 - Place the cursor at channel 115 to monitor the counts. |
Remark |
2669 - 2559 - Collect stage 1 spectrum; Remark:2598 |
STEP: 2669 - 2559 - Collect stage 1 spectrum; Remark:2598 PRM-470 Gamma Alignment |
✔ |
2599 |
2599 - Use precision slotted (tweaker) screwdriver to adjust R10 until peak is cente... |
Remark |
2668 - 2576 - Adjust stage 1 gain; Remark:2599 |
STEP: 2668 - 2576 - Adjust stage 1 gain; Remark:2599 PRM-470 Gamma Alignment |
✔ |
2600 |
2600 - The source assay activity is indicated on the certification documents or comm... |
Remark |
2606 - 2604 - Determine assay activity of radioactive source; Remark:2600 |
STEP: 2606 - 2604 - Determine assay activity of radioactive source; Remark:2600 PRM-470 Efficiency Test |
✔ |
2601 |
2601 - IO PRM-470 Source on Gamma Detector |
Remark |
2667 - 2575 - Verify Cs-137 source is on center of gamma detector; Remark:2601 |
STEP: 2667 - 2575 - Verify Cs-137 source is on center of gamma detector; Remark:2601 PRM-470 Gamma Alignment |
✔ |
2602 |
2602 - Black test lead connects to TP20. Red test lead connects to TP1. |
Remark |
2666 - 2574 - Connect leads to stage 1 test points; Remark:2602 |
STEP: 2666 - 2574 - Connect leads to stage 1 test points; Remark:2602 PRM-470 Gamma Alignment |
✔ |
2603 |
2603 - If needed, convert from microCi to Bq:... |
Remark |
2606 - 2604 - Determine assay activity of radioactive source; Remark:2600 |
STEP: 2606 - 2604 - Determine assay activity of radioactive source; Remark:2600 PRM-470 Efficiency Test |
✔ |
2604 |
2604 - Determine assay activity of radioactive source |
Instruction |
2606 - 2604 - Determine assay activity of radioactive source; Remark:2600 |
STEP: 2606 - 2604 - Determine assay activity of radioactive source; Remark:2600 PRM-470 Efficiency Test |
✔ |
2605 |
2605 - Contact TP34 with tip of red HV probe. |
Remark |
2662 - 2570 - Connect HV probe to test point; Remark:2605 |
STEP: 2662 - 2570 - Connect HV probe to test point; Remark:2605 PRM-470 Gamma Alignment |
✔ |
2606 |
2606 - 2604 - Determine assay activity of radioactive source; Remark:2600 |
Procedure Step |
|
|
✔ |
2607 |
2607 - The HV TP34 is located on the GHA-472 gamma board and might not be clearly la... |
Remark |
2661 - 2569 - Locate HV test point; Remark:2607 |
STEP: 2661 - 2569 - Locate HV test point; Remark:2607 PRM-470 Gamma Alignment |
✔ |
2608 |
2608 - Calculate the number of days, t, between the source assay date and t... |
Remark |
2615 - 2612 - Determine age of source; Remark:2608 |
STEP: 2615 - 2612 - Determine age of source; Remark:2608 PRM-470 Efficiency Test |
✔ |
2609 |
2609 - Connect black test lead of HV probe to TP38. Verify good connection. |
Remark |
2660 - 2568 - Connect HV probe to ground; Remark:2609 |
STEP: 2660 - 2568 - Connect HV probe to ground; Remark:2609 PRM-470 Gamma Alignment |
✔ |
2610 |
2610 - The ground TP38 is located on the GHA-472 gamma board and might not be clearl... |
Remark |
2659 - 2567 - Locate ground test point; Remark:2610 |
STEP: 2659 - 2567 - Locate ground test point; Remark:2610 PRM-470 Gamma Alignment |
✔ |
2611 |
2611 - There are several online aids available to determine the number of days betwe... |
Remark |
2615 - 2612 - Determine age of source; Remark:2608 |
STEP: 2615 - 2612 - Determine age of source; Remark:2608 PRM-470 Efficiency Test |
✔ |
2612 |
2612 - Determine age of source |
Instruction |
2615 - 2612 - Determine age of source; Remark:2608 |
STEP: 2615 - 2612 - Determine age of source; Remark:2608 PRM-470 Efficiency Test |
✔ |
2613 |
2613 - IO Fluke DMM Dial DC Volt |
Remark |
2658 - 2566 - Switch DMM to DC voltage; Remark:2613 |
STEP: 2658 - 2566 - Switch DMM to DC voltage; Remark:2613 PRM-470 Gamma Alignment PRM-470 NHA-472 Board Replacement |
✔ |
2614 |
2614 - Use Fluke 80K-40 high voltage (HV) probe and Fluke 179 DMM. |
Remark |
2657 - 2565 - Connect HV probe to DMM; Remark:2614 |
STEP: 2657 - 2565 - Connect HV probe to DMM; Remark:2614 PRM-470 Gamma Alignment |
✔ |
2615 |
2615 - 2612 - Determine age of source; Remark:2608 |
Procedure Step |
|
|
✔ |
2616 |
2616 - Use the correct file naming convention. Example: US_Richland_CG_102... |
Remark |
2655 - 2563 - Save stage 2 spectrum; Remark:2616 |
STEP: 2655 - 2563 - Save stage 2 spectrum; Remark:2616 PRM-470 Gamma Alignment |
✔ |
2617 |
2617 - Start data collection. |
Remark |
2654 - 2562 - Collect stage 2 spectrum; Remark:2617 |
STEP: 2654 - 2562 - Collect stage 2 spectrum; Remark:2617 PRM-470 Gamma Alignment |
✔ |
2618 |
2618 - Placing the cursor at the peak location will aid in monitoring the counts in ... |
Remark |
2654 - 2562 - Collect stage 2 spectrum; Remark:2617 |
STEP: 2654 - 2562 - Collect stage 2 spectrum; Remark:2617 PRM-470 Gamma Alignment |
✔ |
2619 |
2619 - Red test lead connects to TP2. |
Remark |
2653 - 2561 - Connect leads to stage 2 test point; Remark:2619 |
STEP: 2653 - 2561 - Connect leads to stage 2 test point; Remark:2619 PRM-470 Gamma Alignment |
✔ |
2620 |
2620 - IO Amptek Save File in DppMCA |
Remark |
2652 - 2560 - Save stage 1 spectrum; Remark:2620 |
STEP: 2652 - 2560 - Save stage 1 spectrum; Remark:2620 PRM-470 Gamma Alignment |
✔ |
2621 |
2621 - Use the correct file naming convention. Example: US_Richland_CG_102... |
Remark |
2652 - 2560 - Save stage 1 spectrum; Remark:2620 |
STEP: 2652 - 2560 - Save stage 1 spectrum; Remark:2620 PRM-470 Gamma Alignment |
✔ |
2622 |
2622 - The traffic light icon will start/stop data acquisition. |
Remark |
2651 - 2559 - Collect stage 1 spectrum; Remark:2622 |
STEP: 2651 - 2559 - Collect stage 1 spectrum; Remark:2622 PRM-470 Gamma Alignment |
✔ |
2623 |
2623 - Placing the cursor at the peak location will aid in monitoring the counts in ... |
Remark |
2651 - 2559 - Collect stage 1 spectrum; Remark:2622 |
STEP: 2651 - 2559 - Collect stage 1 spectrum; Remark:2622 PRM-470 Gamma Alignment |
✔ |
2624 |
2624 - Black test lead connects to TP20. Red test lead connects to TP1. |
Remark |
2650 - 2558 - Connect leads to stage 1 test points; Remark:2624 |
STEP: 2650 - 2558 - Connect leads to stage 1 test points; Remark:2624 PRM-470 Gamma Alignment |
✔ |
2625 |
2625 - Center the source on the detector. |
Remark |
2649 - 2557 - Place Cs-137 source on gamma detector; Remark:2625 |
STEP: 2649 - 2557 - Place Cs-137 source on gamma detector; Remark:2625 PRM-470 Gamma Alignment |
✔ |
2626 |
2626 - Settings should match the image below. |
Remark |
2648 - 2556 - Verify MCA settings; Remark:2626 |
STEP: 2648 - 2556 - Verify MCA settings; Remark:2626 PRM-470 Gamma Alignment |
✔ |
2627 |
2627 - IO Amptek Icon DppMCA |
Remark |
2647 - 2555 - Start Amptek software; Remark:2627 |
STEP: 2647 - 2555 - Start Amptek software; Remark:2627 PRM-470 Gamma Alignment |
✔ |
2629 |
2629 - Connect to the SIGNAL input. |
Remark |
2645 - 2553 - Attach test leads to MCA; Remark:2629 |
STEP: 2645 - 2553 - Attach test leads to MCA; Remark:2629 PRM-470 Gamma Alignment |
✔ |
2630 |
2630 - Use provided Mini-USB [universal serial bus] to USB cable. |
Remark |
2644 - 2552 - Connect MCA to computer; Remark:2630 |
STEP: 2644 - 2552 - Connect MCA to computer; Remark:2630 PRM-470 Gamma Alignment |
✔ |
2631 |
2631 - IO PRM-470 Cover Open Action |
Remark |
2642 - 262 - Remove instrument cover; Remark:2631 |
STEP: 2642 - 262 - Remove instrument cover; Remark:2631 PRM-470 Gamma Alignment |
✔ |
2632 |
2632 - 2549 - Prepare instrument; Remark: |
Procedure Step |
|
|
✔ |