5-mm nut (1/4 inch) nut driver or socket
PackEye Reseat FHT 681 Connections
Last Updated: 04/24/2025 1:42 AM
The following table lists all the components that make up the document.
PRM-470 PRCB-472 Board Replacement
Last Updated: 04/24/2025 1:34 AM
The following table lists all the components that make up the document.
PRM-470 GHA-472 Board Replacement
Last Updated: 04/24/2025 1:34 AM
The following table lists all the components that make up the document.
Title | Type | Status | Last Updated |
---|---|---|---|
Rapiscan PRM-470 CG | Device
|
Published
|
10/28/2024 3:40 PM
|
Rapiscan PRM-470 CGN | Device
|
Published
|
10/28/2024 3:33 PM
|
247 - 257 - Prepare instrument; Remark: | Procedure Step
|
Published
|
04/11/2025 9:08 PM
|
257 - Prepare instrument | Instruction
|
Published
|
04/11/2025 9:07 PM
|
607 - 205 - Disconnect charger; Remark: | Procedure Step
|
Published
|
07/23/2021 2:42 PM
|
205 - Disconnect charger | Instruction
|
Published
|
07/23/2021 2:42 PM
|
314 - 313 - Power off instrument; Remark: | Procedure Step
|
Published
|
08/12/2021 6:54 AM
|
313 - Power off instrument | Instruction
|
Published
|
07/23/2021 2:41 PM
|
275 - 65 - Loosen four (4) cover screws; Remark:264 | Procedure Step
|
Published
|
07/26/2021 12:42 PM
|
65 - Loosen four (4) cover screws | Instruction
|
Published
|
07/22/2021 12:38 PM
|
264 - Use a medium Phillips (PH2) screwdriver. Screws do not need to be completely ... | Remark
|
Published
|
07/20/2021 3:59 PM
|
263 - 262 - Remove instrument cover; Remark:413 | Procedure Step
|
Published
|
08/11/2021 1:41 PM
|
2771 - Note : There are high-voltage detector circuit boards inside the instrument; however... | Annotation
|
Published
|
10/04/2022 11:06 AM
|
262 - Remove instrument cover | Instruction
|
Published
|
07/20/2021 3:35 PM
|
413 - PRM-470 Remove Instrument Cover | Remark
|
Published
|
11/01/2024 8:32 PM
|
267 - 266 - Locate battery connection; Remark:272 | Procedure Step
|
Published
|
08/11/2021 1:42 PM
|
3033 - Note : PRM-470 CGN models have an additional board and connectors not shown in remar... | Annotation
|
Published
|
10/04/2022 11:07 AM
|
266 - Locate battery connection | Instruction
|
Published
|
07/20/2021 3:36 PM
|
272 - Battery connection is labeled 1. | Remark
|
Published
|
07/21/2021 12:11 PM
|
271 - 270 - Disconnect battery; Remark:414 | Procedure Step
|
Published
|
08/11/2021 1:42 PM
|
1345 - Note : It is good practice to ensure all cables and connectors are labeled prior to ... | Annotation
|
Published
|
10/04/2022 11:08 AM
|
270 - Disconnect battery | Instruction
|
Published
|
07/20/2021 3:37 PM
|
414 - PRM-470_Disconnect_battery | Remark
|
Published
|
11/02/2024 1:21 PM
|
443 - 442 - Disconnect remaining connectors; Remark: | Procedure Step
|
Published
|
08/11/2021 1:43 PM
|
442 - Disconnect remaining connectors | Instruction
|
Published
|
07/22/2021 12:39 PM
|
571 - 570 - Uninstall faulty GHA-472; Remark: | Procedure Step
|
Published
|
08/12/2021 6:55 AM
|
570 - Uninstall faulty GHA-472 | Instruction
|
Published
|
08/11/2021 4:34 PM
|
478 - 476 - Remove mounting nut; Remark:477 | Procedure Step
|
Published
|
08/11/2021 1:54 PM
|
476 - Remove mounting nut | Instruction
|
Published
|
08/07/2021 10:57 AM
|
477 - PRM-470 - Removing GHA-472 mounting nut | Remark
|
Published
|
11/02/2024 2:00 PM
|
481 - 479 - Remove GHA-472 board; Remark:480 | Procedure Step
|
Published
|
08/11/2021 1:55 PM
|
479 - Remove GHA-472 board | Instruction
|
Published
|
07/22/2021 12:56 PM
|
480 - Gently pry up the GHA-472 board from the PRCB-472 board. | Remark
|
Published
|
07/22/2021 1:13 PM
|
741 - 740 - Install new GHA-472 board; Remark: | Procedure Step
|
Published
|
08/12/2021 6:56 AM
|
740 - Install new GHA-472 board | Instruction
|
Published
|
08/11/2021 4:35 PM
|
484 - 482 - Replace GHA-472 board; Remark:483 | Procedure Step
|
Published
|
08/11/2021 1:55 PM
|
482 - Replace GHA-472 board | Instruction
|
Published
|
07/22/2021 12:56 PM
|
483 - Verify connectors are correctly aligned then press down. | Remark
|
Published
|
07/22/2021 1:14 PM
|
744 - 743 - Reinstall mounting nut; Remark:489 | Procedure Step
|
Published
|
08/12/2021 6:56 AM
|
504 - Caution : Do not overtighten the mounting nut. | Annotation
|
Published
|
10/04/2022 11:11 AM
|
743 - Reinstall mounting nut | Instruction
|
Published
|
08/11/2021 4:36 PM
|
489 - PRM-470 - Location of GHA-472 mounting nut | Remark
|
Published
|
11/02/2024 2:01 PM
|
303 - 302 - Reassemble instrument; Remark: | Procedure Step
|
Published
|
10/07/2022 1:49 PM
|
302 - Reassemble instrument | Instruction
|
Published
|
06/16/2021 11:28 PM
|
500 - 498 - Reconnect all connectors except battery; Remark:499 | Procedure Step
|
Published
|
08/11/2021 2:02 PM
|
498 - Reconnect all connectors except battery | Instruction
|
Published
|
07/22/2021 1:02 PM
|
499 - Do not connect location 1. | Remark
|
Published
|
07/22/2021 1:17 PM
|
306 - 305 - Reconnect battery; Remark:416 | Procedure Step
|
Published
|
08/11/2021 3:11 PM
|
305 - Reconnect battery | Instruction
|
Published
|
07/29/2021 3:48 PM
|
416 - PRM-470 Battery Replacement - Reconnect battery | Remark
|
Published
|
11/02/2024 2:02 PM
|
308 - 307 - Replace front cover; Remark: | Procedure Step
|
Published
|
08/11/2021 2:03 PM
|
304 - Caution : Ensure all wiring is inside the instrument while replacing cover. | Annotation
|
Published
|
10/04/2022 11:10 AM
|
307 - Replace front cover | Instruction
|
Published
|
07/20/2021 3:57 PM
|
310 - 309 - Tighten four (4) cover screws; Remark:417 | Procedure Step
|
Published
|
08/11/2021 2:04 PM
|
569 - Caution : Do not overtighten screws. | Annotation
|
Published
|
06/16/2021 2:31 PM
|
309 - Tighten four (4) cover screws | Instruction
|
Published
|
07/22/2021 1:02 PM
|
417 - Use a medium Phillips (PH2) screwdriver. | Remark
|
Published
|
07/22/2021 1:18 PM
|
747 - 746 - Perform gamma alignment; Remark:745 | Procedure Step
|
Published
|
08/12/2021 6:56 AM
|
746 - Perform gamma alignment | Instruction
|
Published
|
08/11/2021 4:37 PM
|
745 - An alignment is required following replacement of the gamma board or the gamm... | Remark
|
Published
|
08/12/2021 7:00 AM
|
322 - 321 - Document maintenance actions; Remark: | Procedure Step
|
Published
|
06/17/2021 9:49 AM
|
321 - Document maintenance actions | Instruction
|
Published
|
04/21/2025 11:19 AM
|
2869 - 2585 - Document maintenance performed; Remark:2866 | Procedure Step
|
Published
|
06/18/2021 5:58 PM
|
2585 - Document maintenance performed | Instruction
|
Published
|
07/09/2021 12:15 PM
|
2866 - Record observations, times, and results for the maintenance report. | Remark
|
Published
|
04/21/2025 11:39 AM
|
4706 - 4705 - Submit report; Remark:4864 | Procedure Step
|
Published
|
06/29/2022 9:50 AM
|
4705 - Submit report | Instruction
|
Published
|
06/29/2022 9:50 AM
|
4864 - As specified by management or contractual obligations. | Remark
|
Published
|
07/28/2022 1:36 PM
|
Corrective Maintenance Procedure | Document Type
|
Published
|
03/02/2020 3:32 PM
|
20 minutes | Duration
|
Published
|
05/18/2020 5:44 PM
|
As Needed | Frequency
|
Published
|
04/01/2020 11:36 AM
|
Note | Annotation Type
|
Published
|
03/02/2020 3:25 PM
|
Caution | Annotation Type
|
Published
|
03/02/2020 3:24 PM
|
Technician 2 | Skill Level
|
Published
|
04/09/2020 1:17 AM
|
Medium Phillips (PH2) screwdriver | Tools
|
Published
|
04/24/2020 4:40 PM
|
Small Phillips (PH1) screwdriver | Tools
|
Published
|
05/14/2020 2:48 PM
|
5-mm (1/4 inch) nut driver or socket | Tools
|
Published
|
05/14/2020 3:21 PM
|
Needle nose pliers | Tools
|
Published
|
05/06/2020 4:10 PM
|
PRM470_Remove_Screws_Top_Case | படம்
|
Published
|
05/08/2020 6:05 PM
|
PRM-470_di_CGN_open_00536 | படம்
|
Published
|
02/19/2023 11:26 AM
|
Battery_connection_is_labeled_1 | படம்
|
Published
|
02/19/2023 10:46 AM
|
PRM-470_Disconnect_battery | படம்
|
Published
|
05/09/2020 8:40 PM
|
PRM-470 - GHA-472 mounting nut location | படம்
|
Published
|
02/19/2023 11:37 AM
|
PRM-470 - GHA-472 mounting nut removal | படம்
|
Published
|
05/12/2020 1:29 PM
|
PRM-470 - Removing GHA-472 board | படம்
|
Published
|
05/12/2020 1:40 PM
|
PRM-470 - Re-seating GHA-472 board | படம்
|
Published
|
05/12/2020 1:47 PM
|
PRM-470 - Re-seating the GHA-472 board | படம்
|
Published
|
05/12/2020 1:53 PM
|
PRM-470 - GHA-472 mounting nut location | படம்
|
Published
|
05/12/2020 2:00 PM
|
PRM470_Battery_connection_is_labeled_1 | படம்
|
Published
|
02/19/2023 10:40 AM
|
PRM-470_Reconnect_battery | படம்
|
Published
|
05/10/2020 8:16 PM
|
PRM-470_Tighten_4_cover_screws | படம்
|
Published
|
05/10/2020 8:22 PM
|
PRM-470 Check Connections and Reseat Boards
Last Updated: 04/24/2025 1:34 AM
The following table lists all the components that make up the document.