Rapiscan CM-267 Conveyor Monitor |
Device
|
Published
|
06/27/2024 1:02 PM
|
Rapiscan PM-700 Pedestrian Monitor |
Device
|
Published
|
06/20/2024 11:38 AM
|
Rapiscan TM-850 Rail Monitor |
Device
|
Published
|
09/18/2024 10:28 AM
|
Rapiscan VM-250 Vehicle Monitor |
Device
|
Published
|
10/14/2024 9:50 AM
|
1402 - 7927 - Establish Initial Conditions; Remark: |
Procedure Step
|
Published
|
09/30/2022 1:47 PM
|
7927 - Establish Initial Conditions |
Instruction
|
Published
|
07/12/2023 12:23 AM
|
7268 - 7231 - Close lane; Remark:7233 |
Procedure Step
|
Published
|
04/27/2023 7:01 PM
|
9053 - Warning : Traffic should temporarily be rerouted or halted during conduction of this pr... |
Annotation
|
Published
|
09/27/2023 9:09 AM
|
7231 - Close lane |
Instruction
|
Published
|
04/18/2023 1:00 PM
|
7233 - Use orange safety (traffic control) cones to setup barriers. Practice establi... |
Remark
|
Published
|
04/24/2023 12:18 PM
|
8244 - 7683 - Record SC-770 parameter values; Remark:8243 |
Procedure Step
|
Published
|
09/06/2023 3:59 PM
|
7683 - Record SC-770 parameter values |
Instruction
|
Published
|
07/02/2023 12:09 AM
|
8243 - If possible, record SC-770 parameter settings on a blank FCT datasheet for us... |
Remark
|
Published
|
09/06/2023 3:59 PM
|
7270 - 7235 - Power off RPM; Remark:7236 |
Procedure Step
|
Published
|
09/01/2023 7:57 PM
|
7235 - Power off RPM |
Instruction
|
Published
|
04/24/2023 12:30 PM
|
7236 - Move LD-260 switch to OFF position. The PWR ON |
Remark
|
Published
|
04/27/2023 4:25 PM
|
10320 - 10319 - Uninstall Faulty SC-771 Controller Board; Remark: |
Procedure Step
|
Published
|
11/17/2023 1:10 PM
|
10319 - Uninstall Faulty SC-771 Controller Board |
Instruction
|
Published
|
11/17/2023 1:05 PM
|
8239 - 8238 - Loosen SC-770 cover screws; Remark:8237 |
Procedure Step
|
Published
|
09/06/2023 4:14 PM
|
8238 - Loosen SC-770 cover screws |
Instruction
|
Published
|
09/06/2023 4:03 PM
|
8237 - Use the medium Phillips screwdriver to loosen screws. The screws should be ca... |
Remark
|
Published
|
09/06/2023 4:14 PM
|
9716 - |
Remark
|
Published
|
10/13/2023 2:38 PM
|
8240 - 8235 - Pull cover straight out and away from SC-770 body before rotating lid down; Remark:9715 |
Procedure Step
|
Published
|
09/06/2023 4:18 PM
|
8236 - Caution : Do not rotate the lid down before pulling it straight away from the SC-770 bo... |
Annotation
|
Published
|
09/06/2023 4:18 PM
|
8235 - Pull cover straight out and away from SC-770 body before rotating lid down |
Instruction
|
Published
|
09/06/2023 4:17 PM
|
9715 - |
Remark
|
Published
|
10/13/2023 2:36 PM
|
8246 - |
Remark
|
Published
|
09/06/2023 4:32 PM
|
8247 - 8245 - Disconnect all wiring harness assembly/connectors and Ethernet cable from SC-...; Remark:8276 |
Procedure Step
|
Published
|
09/06/2023 4:35 PM
|
1345 - Note : It is good practice to ensure all cables and connectors are labeled prior to ... |
Annotation
|
Published
|
10/04/2022 11:08 AM
|
8245 - Disconnect all wiring harness assembly/connectors and Ethernet cable from SC-... |
Instruction
|
Published
|
09/06/2023 4:33 PM
|
8276 - |
Remark
|
Published
|
09/07/2023 3:28 PM
|
8274 - 8273 - Remove 8 mounting screws; Remark:8272 |
Procedure Step
|
Published
|
09/07/2023 2:40 PM
|
8273 - Remove 8 mounting screws |
Instruction
|
Published
|
09/07/2023 2:40 PM
|
8272 - Do not lose the screws. They are reused to secure the SC-771 board. |
Remark
|
Published
|
09/07/2023 2:40 PM
|
8275 - 8271 - Remove board from SC-770 controller module; Remark: |
Procedure Step
|
Published
|
09/07/2023 2:41 PM
|
8271 - Remove board from SC-770 controller module |
Instruction
|
Published
|
09/07/2023 2:41 PM
|
3397 - 3395 - Label faulty component; Remark:3396 |
Procedure Step
|
Published
|
07/21/2024 6:59 AM
|
3395 - Label faulty component |
Instruction
|
Published
|
08/07/2021 11:07 AM
|
3396 - Use tag or tape. Include date of removal, description of failure symptoms, co... |
Remark
|
Published
|
08/09/2021 11:35 AM
|
8270 - 8269 - Install New SC-771 Board; Remark: |
Procedure Step
|
Published
|
09/07/2023 2:44 PM
|
8269 - Install New SC-771 Board |
Instruction
|
Published
|
09/07/2023 2:44 PM
|
8266 - 8265 - Install new SC-771 board; Remark:8264 |
Procedure Step
|
Published
|
09/07/2023 2:46 PM
|
8265 - Install new SC-771 board |
Instruction
|
Published
|
09/07/2023 2:45 PM
|
8264 - The spare SC-771 should include a rabbit board. If it does not, install one a... |
Remark
|
Published
|
09/07/2023 2:45 PM
|
8267 - 8262 - Reconnect all wiring harness assembly/connectors and Ethernet cable; Remark: |
Procedure Step
|
Published
|
09/07/2023 2:47 PM
|
8263 - Caution : Proper connection of wiring harnesses and Ethernet cable is critical |
Annotation
|
Published
|
09/07/2023 2:53 PM
|
8262 - Reconnect all wiring harness assembly/connectors and Ethernet cable |
Instruction
|
Published
|
09/07/2023 2:46 PM
|
8268 - 8261 - Close SC-770 module cover and tighten all screws; Remark: |
Procedure Step
|
Published
|
09/07/2023 2:50 PM
|
8261 - Close SC-770 module cover and tighten all screws |
Instruction
|
Published
|
09/07/2023 2:50 PM
|
7279 - 7249 - Return equipment to normal operating condition; Remark: |
Procedure Step
|
Published
|
04/27/2023 4:13 PM
|
7249 - Return equipment to normal operating condition |
Instruction
|
Published
|
04/08/2025 3:22 PM
|
7280 - 7250 - Power on RPM; Remark:7251 |
Procedure Step
|
Published
|
04/27/2023 4:14 PM
|
7250 - Power on RPM |
Instruction
|
Published
|
05/01/2023 8:31 AM
|
7251 - Move LD-260 switch to ON position. The LED PWR ON |
Remark
|
Published
|
05/10/2023 3:14 PM
|
8256 - 8193 - Verify Rabbit board firmware is correct; Remark:8194 |
Procedure Step
|
Published
|
09/07/2023 2:57 PM
|
8254 - Note : If firmware version is not correct, perform procedure DET-RPM-RAP-CM02 to upd... |
Annotation
|
Published
|
09/07/2023 2:56 PM
|
8255 - Caution : The firmware version must be correct to operate the system |
Annotation
|
Published
|
09/07/2023 2:57 PM
|
8193 - Verify Rabbit board firmware is correct |
Instruction
|
Published
|
09/01/2023 7:18 PM
|
8194 - Enter Program Mode by pressing “0.” Enter the password ... |
Remark
|
Published
|
09/01/2023 7:23 PM
|
8257 - 8252 - Input currently approved SC-770 parameter settings; Remark:8251 |
Procedure Step
|
Published
|
09/07/2023 3:02 PM
|
8253 - Caution : To ensure proper RPM operation, careful attention must be paid when entering ... |
Annotation
|
Published
|
09/07/2023 3:00 PM
|
8252 - Input currently approved SC-770 parameter settings |
Instruction
|
Published
|
09/07/2023 2:59 PM
|
8251 - Use parameters previously recorded in Step 1-3. If those were not recorded, t... |
Remark
|
Published
|
09/07/2023 3:00 PM
|
8258 - 319 - Perform operational test; Remark:8219 |
Procedure Step
|
Published
|
04/08/2025 2:11 PM
|
319 - Perform operational test |
Instruction
|
Published
|
06/10/2021 8:31 PM
|
8219 - DET-RPM-RAP-RM03, Operational Testing procedure. |
Remark
|
Published
|
09/01/2023 8:45 PM
|
8260 - 8250 - Reopen Lane; Remark:8249 |
Procedure Step
|
Published
|
09/07/2023 3:09 PM
|
8250 - Reopen Lane |
Instruction
|
Published
|
09/07/2023 3:09 PM
|
8249 - Remove orange safety (traffic control) cones |
Remark
|
Published
|
09/07/2023 3:09 PM
|
7842 - 7820 - Inform system operators upon completion of maintenance action; Remark: |
Procedure Step
|
Published
|
07/07/2023 11:15 PM
|
7820 - Inform system operators upon completion of maintenance action |
Instruction
|
Published
|
07/07/2023 10:02 PM
|
322 - 321 - Document maintenance actions; Remark: |
Procedure Step
|
Published
|
06/17/2021 9:49 AM
|
321 - Document maintenance actions |
Instruction
|
Published
|
04/21/2025 11:19 AM
|
2869 - 2585 - Document maintenance performed; Remark:2866 |
Procedure Step
|
Published
|
06/18/2021 5:58 PM
|
2585 - Document maintenance performed |
Instruction
|
Published
|
07/09/2021 12:15 PM
|
2866 - Record observations, times, and results for the maintenance report. |
Remark
|
Published
|
04/21/2025 11:39 AM
|
4706 - 4705 - Submit report; Remark:4864 |
Procedure Step
|
Published
|
06/29/2022 9:50 AM
|
4705 - Submit report |
Instruction
|
Published
|
06/29/2022 9:50 AM
|
4864 - As specified by management or contractual obligations. |
Remark
|
Published
|
07/28/2022 1:36 PM
|
Corrective Maintenance Procedure |
Document Type
|
Published
|
03/02/2020 3:32 PM
|
30 minutes |
Duration
|
Published
|
04/01/2020 11:35 AM
|
Upon SC-771 board failure |
Frequency
|
Published
|
11/17/2023 12:47 PM
|
Warning |
Annotation Type
|
Published
|
03/02/2020 3:25 PM
|
Caution |
Annotation Type
|
Published
|
03/02/2020 3:24 PM
|
Note |
Annotation Type
|
Published
|
03/02/2020 3:25 PM
|
Technician 2 |
Skill Level
|
Published
|
04/09/2020 1:17 AM
|
Phillips screwdriver, medium |
Replacement Parts
|
Published
|
07/07/2023 11:39 PM
|
Phillips screwdriver, small |
Replacement Parts
|
Published
|
07/07/2023 11:39 PM
|
LD-260 Disconnect Switch Power Off |
படம்
|
Published
|
04/24/2023 12:49 PM
|
SC-770 Controller Screws |
படம்
|
Published
|
09/01/2023 5:56 PM
|
Loosen SC-770 cover screws |
படம்
|
Published
|
09/20/2023 1:14 PM
|
Loosen SC-770 cover screws zoom in |
படம்
|
Published
|
10/13/2023 2:17 PM
|
SC-770 lid cover removal instruction |
படம்
|
Published
|
10/13/2023 2:22 PM
|
SC-770 lid cover removal |
படம்
|
Published
|
09/06/2023 4:31 PM
|
Disconnect all wiring harness assembly/connectors and Ethernet cable from SC-771 |
படம்
|
Published
|
09/07/2023 3:27 PM
|
LD-260 Disconnect Switch Power On |
படம்
|
Published
|
05/04/2023 3:37 PM
|