Rapiscan TM-850 Rail Monitor |
Device
|
Published
|
09/18/2024 10:28 AM
|
Rapiscan VM-250 Vehicle Monitor |
Device
|
Published
|
10/14/2024 9:50 AM
|
Rapiscan PM-700 Pedestrian Monitor |
Device
|
Published
|
06/20/2024 11:38 AM
|
Rapiscan CM-267 Conveyor Monitor |
Device
|
Published
|
06/27/2024 1:02 PM
|
1402 - 7927 - Establish Initial Conditions; Remark: |
Procedure Step
|
Published
|
09/30/2022 1:47 PM
|
7927 - Establish Initial Conditions |
Instruction
|
Published
|
07/12/2023 12:23 AM
|
7268 - 7231 - Close lane; Remark:7233 |
Procedure Step
|
Published
|
04/27/2023 7:01 PM
|
9053 - Warning : Traffic should temporarily be rerouted or halted during conduction of this pr... |
Annotation
|
Published
|
09/27/2023 9:09 AM
|
7231 - Close lane |
Instruction
|
Published
|
04/18/2023 1:00 PM
|
7233 - Use orange safety (traffic control) cones to setup barriers. Practice establi... |
Remark
|
Published
|
04/24/2023 12:18 PM
|
7269 - 7232 - Open RPM door; Remark:7234 |
Procedure Step
|
Published
|
04/27/2023 7:02 PM
|
7232 - Open RPM door |
Instruction
|
Published
|
04/18/2023 1:02 PM
|
7234 - Open all doors needed to access components. |
Remark
|
Published
|
04/19/2025 7:48 PM
|
7270 - 7235 - Power off RPM; Remark:7236 |
Procedure Step
|
Published
|
09/01/2023 7:57 PM
|
7235 - Power off RPM |
Instruction
|
Published
|
04/24/2023 12:30 PM
|
7236 - Move LD-260 switch to OFF position. The PWR ON |
Remark
|
Published
|
04/27/2023 4:25 PM
|
8072 - 10288 - Turn AC Power Off; Remark: |
Procedure Step
|
Published
|
07/31/2023 11:51 AM
|
10288 - Turn AC Power Off |
Instruction
|
Published
|
11/16/2023 6:34 PM
|
10157 - 10154 - Turn RPM AC power input breaker switch to “OFF” position; Remark:10153 |
Procedure Step
|
Published
|
10/23/2023 11:08 AM
|
10155 - Warning : 120/240 Vac will still be present at the AC power terminal block and at the A... |
Annotation
|
Published
|
10/23/2023 11:06 AM
|
10156 - Note : Normally the “OFF” position will be when the switch is in the down positi... |
Annotation
|
Published
|
10/23/2023 11:08 AM
|
10154 - Turn RPM AC power input breaker switch to “OFF” position |
Instruction
|
Published
|
10/23/2023 11:04 AM
|
10153 - Note the different styles of AC breakers: 1. Black breaker/green so... |
Remark
|
Published
|
10/23/2023 11:05 AM
|
10158 - 10152 - Confirm AC LED on LD-260 is no longer lit once AC breaker ha...; Remark:10151 |
Procedure Step
|
Published
|
04/13/2025 6:14 PM
|
10152 - Confirm AC LED on LD-260 is no longer lit once AC breaker ha... |
Instruction
|
Published
|
04/13/2025 5:31 PM
|
10151 - confirming LD-260 power is off |
Remark
|
Published
|
10/23/2023 11:32 AM
|
10150 - 10149 - Uninstall Faulty +12V Battery; Remark: |
Procedure Step
|
Published
|
10/23/2023 11:35 AM
|
10149 - Uninstall Faulty +12V Battery |
Instruction
|
Published
|
10/23/2023 11:34 AM
|
10142 - 10141 - Disconnect battery at Molex plug; Remark:10140 |
Procedure Step
|
Published
|
10/23/2023 11:42 AM
|
10141 - Disconnect battery at Molex plug |
Instruction
|
Published
|
10/23/2023 11:35 AM
|
10140 - Unplug the 2-conductor Molex by opening latch and separate ends by pulling ap... |
Remark
|
Published
|
10/23/2023 11:42 AM
|
10143 - 10139 - Lift battery out of RPM cabinet; Remark:10137 |
Procedure Step
|
Published
|
10/23/2023 11:45 AM
|
10139 - Lift battery out of RPM cabinet |
Instruction
|
Published
|
10/23/2023 11:45 AM
|
10137 - The battery posts may be covered with a protective, non-conductive blanket to... |
Remark
|
Published
|
10/23/2023 11:45 AM
|
10144 - 10136 - Disconnect wiring harness from failed battery; Remark:10135 |
Procedure Step
|
Published
|
10/23/2023 11:47 AM
|
10136 - Disconnect wiring harness from failed battery |
Instruction
|
Published
|
10/23/2023 11:46 AM
|
10135 - Remove the wiring harness from the failed battery in preparation for installa... |
Remark
|
Published
|
10/23/2023 11:46 AM
|
10145 - 10134 - Attach wiring harness to new battery; Remark:10132 |
Procedure Step
|
Published
|
10/23/2023 11:51 AM
|
10134 - Attach wiring harness to new battery |
Instruction
|
Published
|
10/23/2023 11:49 AM
|
10132 - Install the wiring harness on the new battery. |
Remark
|
Published
|
10/23/2023 11:50 AM
|
10133 - If the non-conductive blanket was present on the old battery install it on th... |
Remark
|
Published
|
10/23/2023 11:50 AM
|
10146 - 10131 - Place new battery into position in RPM cabinet; Remark: |
Procedure Step
|
Published
|
10/23/2023 11:51 AM
|
10131 - Place new battery into position in RPM cabinet |
Instruction
|
Published
|
10/23/2023 11:51 AM
|
10147 - 10130 - Reinstall protective cover; Remark: |
Procedure Step
|
Published
|
10/23/2023 11:52 AM
|
10130 - Reinstall protective cover |
Instruction
|
Published
|
10/23/2023 11:52 AM
|
10148 - 10129 - Reconnect battery; Remark:10128 |
Procedure Step
|
Published
|
10/23/2023 11:54 AM
|
10129 - Reconnect battery |
Instruction
|
Published
|
10/23/2023 11:52 AM
|
10128 - Reconnect the two halves of the Molex connector; slide the two halves togethe... |
Remark
|
Published
|
10/23/2023 11:54 AM
|
3397 - 3395 - Label faulty component; Remark:3396 |
Procedure Step
|
Published
|
07/21/2024 6:59 AM
|
3395 - Label faulty component |
Instruction
|
Published
|
08/07/2021 11:07 AM
|
3396 - Use tag or tape. Include date of removal, description of failure symptoms, co... |
Remark
|
Published
|
08/09/2021 11:35 AM
|
10127 - 10307 - Turn AC Power On; Remark: |
Procedure Step
|
Published
|
10/23/2023 11:55 AM
|
10307 - Turn AC Power On |
Instruction
|
Published
|
11/16/2023 7:01 PM
|
10125 - 10124 - Turn power ON at AC breaker; Remark:10153 |
Procedure Step
|
Published
|
10/23/2023 12:08 PM
|
10124 - Turn power ON at AC breaker |
Instruction
|
Published
|
10/23/2023 12:06 PM
|
10310 - 10308 - Confirm AC LED on LD-260 is lit; Remark:10309 |
Procedure Step
|
Published
|
04/13/2025 6:13 PM
|
10308 - Confirm AC LED on LD-260 is lit |
Instruction
|
Published
|
04/13/2025 5:31 PM
|
10309 - AC Present |
Remark
|
Published
|
11/16/2023 7:23 PM
|
7279 - 7249 - Return equipment to normal operating condition; Remark: |
Procedure Step
|
Published
|
04/27/2023 4:13 PM
|
7249 - Return equipment to normal operating condition |
Instruction
|
Published
|
04/08/2025 3:22 PM
|
7280 - 7250 - Power on RPM; Remark:7251 |
Procedure Step
|
Published
|
04/27/2023 4:14 PM
|
7250 - Power on RPM |
Instruction
|
Published
|
05/01/2023 8:31 AM
|
7251 - Move LD-260 switch to ON position. The LED PWR ON |
Remark
|
Published
|
05/10/2023 3:14 PM
|
7281 - 7252 - Verify RPM start-up; Remark:7253 |
Procedure Step
|
Published
|
04/20/2025 3:26 PM
|
7252 - Verify RPM start-up |
Instruction
|
Published
|
04/27/2023 2:23 PM
|
7253 - RPM will perform a power on self-test (POST) and collect a background radiati... |
Remark
|
Published
|
05/10/2023 3:14 PM
|
9735 - 319 - Perform operational test; Remark:9733 |
Procedure Step
|
Published
|
04/08/2025 2:22 PM
|
319 - Perform operational test |
Instruction
|
Published
|
06/10/2021 8:31 PM
|
9733 - DET-RPM-RAP-RM03. |
Remark
|
Published
|
10/13/2023 4:08 PM
|
7282 - 7254 - Confirm network connection; Remark:7255 |
Procedure Step
|
Published
|
04/27/2023 4:15 PM
|
7254 - Confirm network connection |
Instruction
|
Published
|
04/27/2023 2:22 PM
|
7255 - Contact operators to confirm communications have been reestablished between RPM ... |
Remark
|
Published
|
05/10/2023 3:15 PM
|
7283 - 7256 - Close and lock all RPM doors; Remark: |
Procedure Step
|
Published
|
09/01/2023 11:45 PM
|
7256 - Close and lock all RPM doors |
Instruction
|
Published
|
04/27/2023 2:21 PM
|
7842 - 7820 - Inform system operators upon completion of maintenance action; Remark: |
Procedure Step
|
Published
|
07/07/2023 11:15 PM
|
7820 - Inform system operators upon completion of maintenance action |
Instruction
|
Published
|
07/07/2023 10:02 PM
|
322 - 321 - Document maintenance actions; Remark: |
Procedure Step
|
Published
|
06/17/2021 9:49 AM
|
321 - Document maintenance actions |
Instruction
|
Published
|
04/21/2025 11:19 AM
|
2869 - 2585 - Document maintenance performed; Remark:2866 |
Procedure Step
|
Published
|
06/18/2021 5:58 PM
|
2585 - Document maintenance performed |
Instruction
|
Published
|
07/09/2021 12:15 PM
|
2866 - Record observations, times, and results for the maintenance report. |
Remark
|
Published
|
04/21/2025 11:39 AM
|
4706 - 4705 - Submit report; Remark:4864 |
Procedure Step
|
Published
|
06/29/2022 9:50 AM
|
4705 - Submit report |
Instruction
|
Published
|
06/29/2022 9:50 AM
|
4864 - As specified by management or contractual obligations. |
Remark
|
Published
|
07/28/2022 1:36 PM
|
Corrective Maintenance Procedure |
Document Type
|
Published
|
03/02/2020 3:32 PM
|
20 minutes |
Duration
|
Published
|
05/18/2020 5:44 PM
|
Upon failure of +12 Vdc battery |
Frequency
|
Published
|
10/23/2023 9:58 AM
|
Warning |
Annotation Type
|
Published
|
03/02/2020 3:25 PM
|
Note |
Annotation Type
|
Published
|
03/02/2020 3:25 PM
|
Technician 2 |
Skill Level
|
Published
|
04/09/2020 1:17 AM
|
Keys to access RPM |
Replacement Parts
|
Published
|
04/27/2023 6:56 PM
|
Phillips screwdriver, medium |
Replacement Parts
|
Published
|
07/07/2023 11:39 PM
|
Permanent marker |
Tools
|
Published
|
10/23/2023 10:07 AM
|
Orange/yellow safety vest |
Replacement Parts
|
Published
|
04/27/2023 6:56 PM
|
Safety shoes |
Replacement Parts
|
Published
|
04/27/2023 6:56 PM
|
safety glasses |
Replacement Parts
|
Published
|
07/02/2023 4:48 PM
|
Ladder; 2 meters, 6 feet tall; non-conducting if required |
Replacement Parts
|
Published
|
07/02/2023 4:48 PM
|
Orange traffic cones |
Replacement Parts
|
Published
|
04/27/2023 6:56 PM
|
LD-260 Disconnect Switch Power Off |
படம்
|
Published
|
04/24/2023 12:49 PM
|
AC Power input breaker |
படம்
|
Published
|
10/23/2023 11:05 AM
|
LD-260 Power off.png |
படம்
|
Published
|
10/23/2023 2:11 PM
|
Disconnect battery at Molex plug (1) |
படம்
|
Published
|
10/23/2023 11:39 AM
|
Disconnect battery at Molex plug (2) |
படம்
|
Published
|
10/23/2023 11:40 AM
|
Disconnect battery at Molex plug (3) |
படம்
|
Published
|
10/23/2023 11:41 AM
|
AC power present |
படம்
|
Published
|
10/23/2023 12:20 PM
|
LD-260 Disconnect Switch Power On |
படம்
|
Published
|
05/04/2023 3:37 PM
|