Rapiscan CM-267 Conveyor Monitor |
Device
|
Published
|
06/27/2024 1:02 PM
|
Rapiscan TM-850 Rail Monitor |
Device
|
Published
|
09/18/2024 10:28 AM
|
Rapiscan VM-250 Vehicle Monitor |
Device
|
Published
|
10/14/2024 9:50 AM
|
Rapiscan PM-700 Pedestrian Monitor |
Device
|
Published
|
06/20/2024 11:38 AM
|
1402 - 7927 - Establish Initial Conditions; Remark: |
Procedure Step
|
Published
|
09/30/2022 1:47 PM
|
7927 - Establish Initial Conditions |
Instruction
|
Published
|
07/12/2023 12:23 AM
|
7372 - 7231 - Close lane; Remark:7233 |
Procedure Step
|
Published
|
09/01/2023 7:52 PM
|
7261 - Warning : Traffic should temporarily be rerouted or halted during this procedure to ens... |
Annotation
|
Published
|
09/28/2023 2:09 PM
|
7231 - Close lane |
Instruction
|
Published
|
04/18/2023 1:00 PM
|
7233 - Use orange safety (traffic control) cones to setup barriers. Practice establi... |
Remark
|
Published
|
04/24/2023 12:18 PM
|
7269 - 7232 - Open RPM door; Remark:7234 |
Procedure Step
|
Published
|
04/27/2023 7:02 PM
|
7232 - Open RPM door |
Instruction
|
Published
|
04/18/2023 1:02 PM
|
7234 - Open all doors needed to access components. |
Remark
|
Published
|
04/19/2025 7:48 PM
|
7374 - 7235 - Power off RPM; Remark:7236 |
Procedure Step
|
Published
|
05/04/2023 4:15 PM
|
7235 - Power off RPM |
Instruction
|
Published
|
04/24/2023 12:30 PM
|
7236 - Move LD-260 switch to OFF position. The PWR ON |
Remark
|
Published
|
04/27/2023 4:25 PM
|
9719 - 9718 - Uninstall Faulty GPRB-756 from SC-770 Controller Module ...; Remark: |
Procedure Step
|
Published
|
10/13/2023 1:48 PM
|
9718 - Uninstall Faulty GPRB-756 from SC-770 Controller Module ... |
Instruction
|
Published
|
10/13/2023 1:48 PM
|
8239 - 8238 - Loosen SC-770 cover screws; Remark:8237 |
Procedure Step
|
Published
|
09/06/2023 4:14 PM
|
8238 - Loosen SC-770 cover screws |
Instruction
|
Published
|
09/06/2023 4:03 PM
|
8237 - Use the medium Phillips screwdriver to loosen screws. The screws should be ca... |
Remark
|
Published
|
09/06/2023 4:14 PM
|
9716 - |
Remark
|
Published
|
10/13/2023 2:38 PM
|
8240 - 8235 - Pull cover straight out and away from SC-770 body before rotating lid down; Remark:9715 |
Procedure Step
|
Published
|
09/06/2023 4:18 PM
|
8236 - Caution : Do not rotate the lid down before pulling it straight away from the SC-770 bo... |
Annotation
|
Published
|
09/06/2023 4:18 PM
|
8235 - Pull cover straight out and away from SC-770 body before rotating lid down |
Instruction
|
Published
|
09/06/2023 4:17 PM
|
9715 - |
Remark
|
Published
|
10/13/2023 2:36 PM
|
8246 - |
Remark
|
Published
|
09/06/2023 4:32 PM
|
9717 - 9714 - Disconnect 3 MOLEX connectors from GPRB-756; Remark:9713 |
Procedure Step
|
Published
|
10/13/2023 2:32 PM
|
7792 - Note : It is good engineering practice to ensure all cables and connectors are label... |
Annotation
|
Published
|
07/07/2023 2:17 PM
|
9714 - Disconnect 3 MOLEX connectors from GPRB-756 |
Instruction
|
Published
|
10/13/2023 2:03 PM
|
9713 - |
Remark
|
Published
|
10/13/2023 2:31 PM
|
9730 - 9729 - Remove 4 Phillips head screws and retain for reuse; Remark: |
Procedure Step
|
Published
|
10/13/2023 2:42 PM
|
9729 - Remove 4 Phillips head screws and retain for reuse |
Instruction
|
Published
|
10/13/2023 2:42 PM
|
9731 - 9728 - Remove faulty GPRB-756; Remark: |
Procedure Step
|
Published
|
10/13/2023 2:42 PM
|
9728 - Remove faulty GPRB-756 |
Instruction
|
Published
|
10/13/2023 2:42 PM
|
3397 - 3395 - Label faulty component; Remark:3396 |
Procedure Step
|
Published
|
07/21/2024 6:59 AM
|
3395 - Label faulty component |
Instruction
|
Published
|
08/07/2021 11:07 AM
|
3396 - Use tag or tape. Include date of removal, description of failure symptoms, co... |
Remark
|
Published
|
08/09/2021 11:35 AM
|
9726 - 9725 - Install New GPRB-756; Remark: |
Procedure Step
|
Published
|
10/13/2023 3:00 PM
|
9725 - Install New GPRB-756 |
Instruction
|
Published
|
10/13/2023 2:46 PM
|
9723 - 9722 - Line up the new GPRB-756 with the screw holes, and re-install the four Philli...; Remark: |
Procedure Step
|
Published
|
10/13/2023 3:01 PM
|
9722 - Line up the new GPRB-756 with the screw holes, and re-install the four Philli... |
Instruction
|
Published
|
10/13/2023 3:01 PM
|
9724 - 9721 - Reconnect 3 MOLEX connectors to the GPRB-756; Remark:9720 |
Procedure Step
|
Published
|
10/13/2023 3:04 PM
|
7811 - Caution : Proper connection of cables is critical. |
Annotation
|
Published
|
07/07/2023 9:48 PM
|
9721 - Reconnect 3 MOLEX connectors to the GPRB-756 |
Instruction
|
Published
|
10/13/2023 3:02 PM
|
9720 - |
Remark
|
Published
|
10/13/2023 3:02 PM
|
8268 - 8261 - Close SC-770 module cover and tighten all screws; Remark: |
Procedure Step
|
Published
|
09/07/2023 2:50 PM
|
8261 - Close SC-770 module cover and tighten all screws |
Instruction
|
Published
|
09/07/2023 2:50 PM
|
7280 - 7250 - Power on RPM; Remark:7251 |
Procedure Step
|
Published
|
04/27/2023 4:14 PM
|
7250 - Power on RPM |
Instruction
|
Published
|
05/01/2023 8:31 AM
|
7251 - Move LD-260 switch to ON position. The LED PWR ON |
Remark
|
Published
|
05/10/2023 3:14 PM
|
7279 - 7249 - Return equipment to normal operating condition; Remark: |
Procedure Step
|
Published
|
04/27/2023 4:13 PM
|
7249 - Return equipment to normal operating condition |
Instruction
|
Published
|
04/08/2025 3:22 PM
|
7282 - 7254 - Confirm network connection; Remark:7255 |
Procedure Step
|
Published
|
04/27/2023 4:15 PM
|
7254 - Confirm network connection |
Instruction
|
Published
|
04/27/2023 2:22 PM
|
7255 - Contact operators to confirm communications have been reestablished between RPM ... |
Remark
|
Published
|
05/10/2023 3:15 PM
|
9735 - 319 - Perform operational test; Remark:9733 |
Procedure Step
|
Published
|
04/08/2025 2:22 PM
|
319 - Perform operational test |
Instruction
|
Published
|
06/10/2021 8:31 PM
|
9733 - DET-RPM-RAP-RM03. |
Remark
|
Published
|
10/13/2023 4:08 PM
|
8260 - 8250 - Reopen Lane; Remark:8249 |
Procedure Step
|
Published
|
09/07/2023 3:09 PM
|
8250 - Reopen Lane |
Instruction
|
Published
|
09/07/2023 3:09 PM
|
8249 - Remove orange safety (traffic control) cones |
Remark
|
Published
|
09/07/2023 3:09 PM
|
7842 - 7820 - Inform system operators upon completion of maintenance action; Remark: |
Procedure Step
|
Published
|
07/07/2023 11:15 PM
|
7820 - Inform system operators upon completion of maintenance action |
Instruction
|
Published
|
07/07/2023 10:02 PM
|
322 - 321 - Document maintenance actions; Remark: |
Procedure Step
|
Published
|
06/17/2021 9:49 AM
|
321 - Document maintenance actions |
Instruction
|
Published
|
04/21/2025 11:19 AM
|
2869 - 2585 - Document maintenance performed; Remark:2866 |
Procedure Step
|
Published
|
06/18/2021 5:58 PM
|
2585 - Document maintenance performed |
Instruction
|
Published
|
07/09/2021 12:15 PM
|
2866 - Record observations, times, and results for the maintenance report. |
Remark
|
Published
|
04/21/2025 11:39 AM
|
4706 - 4705 - Submit report; Remark:4864 |
Procedure Step
|
Published
|
06/29/2022 9:50 AM
|
4705 - Submit report |
Instruction
|
Published
|
06/29/2022 9:50 AM
|
4864 - As specified by management or contractual obligations. |
Remark
|
Published
|
07/28/2022 1:36 PM
|
Corrective Maintenance Procedure |
Document Type
|
Published
|
03/02/2020 3:32 PM
|
minutes |
Duration
|
Published
|
05/26/2022 11:41 AM
|
Upon failure of general purpose relay board |
Frequency
|
Published
|
10/13/2023 1:18 PM
|
Warning |
Annotation Type
|
Published
|
03/02/2020 3:25 PM
|
Caution |
Annotation Type
|
Published
|
03/02/2020 3:24 PM
|
Note |
Annotation Type
|
Published
|
03/02/2020 3:25 PM
|
Technician 1 |
Skill Level
|
Published
|
05/14/2020 2:56 PM
|
Phillips screwdriver, medium |
Replacement Parts
|
Published
|
07/07/2023 11:39 PM
|
Keys to access RPM |
Replacement Parts
|
Published
|
04/27/2023 6:56 PM
|
Reflective safety vest if required |
Replacement Parts
|
Published
|
06/20/2023 4:47 PM
|
Ladder; 2 meters, 6 feet tall; non-conducting if required |
Replacement Parts
|
Published
|
07/02/2023 4:48 PM
|
Traffic control cones or equivalent if required |
Replacement Parts
|
Published
|
06/20/2023 4:47 PM
|
Safety glasses if required |
Replacement Parts
|
Published
|
06/20/2023 4:47 PM
|
LD-260 Disconnect Switch Power Off |
படம்
|
Published
|
04/24/2023 12:49 PM
|
SC-770 Controller Screws |
படம்
|
Published
|
09/01/2023 5:56 PM
|
Loosen SC-770 cover screws |
படம்
|
Published
|
09/20/2023 1:14 PM
|
Loosen SC-770 cover screws zoom in |
படம்
|
Published
|
10/13/2023 2:17 PM
|
SC-770 lid cover removal instruction |
படம்
|
Published
|
10/13/2023 2:22 PM
|
SC-770 lid cover removal |
படம்
|
Published
|
09/06/2023 4:31 PM
|
GPRB-756 |
படம்
|
Published
|
10/13/2023 2:27 PM
|
LD-260 Disconnect Switch Power On |
படம்
|
Published
|
05/04/2023 3:37 PM
|