Rapiscan VM-250 Vehicle Monitor |
Device
|
Published
|
10/14/2024 9:50 AM
|
Rapiscan TM-850 Rail Monitor |
Device
|
Published
|
09/18/2024 10:28 AM
|
8468 - 1401 - Establish Initial Conditions; Remark: |
Procedure Step
|
Published
|
09/16/2023 4:47 PM
|
1401 - Establish Initial Conditions |
Instruction
|
Published
|
09/30/2022 3:14 PM
|
8489 - 1401 - Establish Initial Conditions; Remark: |
Procedure Step
|
Published
|
09/24/2023 9:51 AM
|
7265 - Warning : Traffic should temporarily be rerouted or halted during this procedure to ens... |
Annotation
|
Published
|
04/27/2023 1:42 PM
|
8490 - 7592 - Inform system operators; Remark: |
Procedure Step
|
Published
|
09/16/2023 8:49 PM
|
7592 - Inform system operators |
Instruction
|
Published
|
06/29/2023 3:20 PM
|
7454 - 7290 - Disable tamper switches; Remark:7416 |
Procedure Step
|
Published
|
06/02/2023 5:25 PM
|
7290 - Disable tamper switches |
Instruction
|
Published
|
05/01/2023 8:14 AM
|
7416 - Use a magnet to disable tamper switches for all open doors. Use adhesive tape... |
Remark
|
Published
|
06/02/2023 1:18 PM
|
8561 - 7291 - Disable both infrared occupancy sensors; Remark:8514 |
Procedure Step
|
Published
|
09/18/2023 12:05 AM
|
5291 - Note : It is good practice to verify all cables and connectors are labeled prior to ... |
Annotation
|
Published
|
10/24/2022 8:35 AM
|
7291 - Disable both infrared occupancy sensors |
Instruction
|
Published
|
05/01/2023 8:15 AM
|
8514 - Verify sensors mounted in control pillar door are receivers. |
Remark
|
Published
|
09/29/2023 11:52 AM
|
9205 - To disconnect sensor cable, turn collar counterclockwise and pull away from s... |
Remark
|
Published
|
09/29/2023 11:52 AM
|
8221 - 7676 - Brief system operators on expected work, duration, anticipated alarms, and fa...; Remark: |
Procedure Step
|
Published
|
09/01/2023 9:26 PM
|
7676 - Brief system operators on expected work, duration, anticipated alarms, and fa... |
Instruction
|
Published
|
07/01/2023 11:39 PM
|
8890 - 7292 - Uninstall Faulty Nano Controller; Remark: |
Procedure Step
|
Published
|
09/25/2023 7:30 PM
|
7292 - Uninstall Faulty Nano Controller |
Instruction
|
Published
|
05/01/2023 8:18 AM
|
8370 - 8369 - Disconnect RJ-45 Ethernet cable; Remark:8368 |
Procedure Step
|
Published
|
09/25/2023 7:21 PM
|
8369 - Disconnect RJ-45 Ethernet cable |
Instruction
|
Published
|
09/12/2023 10:46 AM
|
8368 - |
Remark
|
Published
|
09/12/2023 10:46 AM
|
8377 - 8376 - Disconnect occupancy sensor wires; Remark:8375 |
Procedure Step
|
Published
|
09/25/2023 7:23 PM
|
8376 - Disconnect occupancy sensor wires |
Instruction
|
Published
|
09/12/2023 10:57 AM
|
8375 - Use small slotted screwdriver. Remove wires from I1 terminal... |
Remark
|
Published
|
09/12/2023 11:01 AM
|
8378 - 8374 - Disconnect power wires; Remark:8373 |
Procedure Step
|
Published
|
09/25/2023 7:24 PM
|
8374 - Disconnect power wires |
Instruction
|
Published
|
09/12/2023 11:01 AM
|
8373 - These wires go to Terminal Block 1 (TB1). Use small slotted screwdriver |
Remark
|
Published
|
09/12/2023 11:03 AM
|
8379 - 8372 - Disconnect occupancy output wire; Remark:8371 |
Procedure Step
|
Published
|
09/25/2023 7:26 PM
|
8372 - Disconnect occupancy output wire |
Instruction
|
Published
|
09/12/2023 11:03 AM
|
8371 - Use small slotted screwdriver. Remove green wire from Q1 ter... |
Remark
|
Published
|
09/12/2023 11:04 AM
|
8891 - 7297 - Remove faulty Nano Controller; Remark:8380 |
Procedure Step
|
Published
|
09/25/2023 7:31 PM
|
8382 - Note : Nano Controller installation may differ from configuration shown in this proc... |
Annotation
|
Published
|
09/12/2023 11:16 AM
|
7297 - Remove faulty Nano Controller |
Instruction
|
Published
|
05/01/2023 8:21 AM
|
8380 - Use slotted screwdriver to pull down tab and rotate Nano Controller up. Use m... |
Remark
|
Published
|
09/12/2023 11:15 AM
|
3397 - 3395 - Label faulty component; Remark:3396 |
Procedure Step
|
Published
|
07/21/2024 6:59 AM
|
3395 - Label faulty component |
Instruction
|
Published
|
08/07/2021 11:07 AM
|
3396 - Use tag or tape. Include date of removal, description of failure symptoms, co... |
Remark
|
Published
|
08/09/2021 11:35 AM
|
8894 - 7298 - Install New Nano Controller; Remark: |
Procedure Step
|
Published
|
09/25/2023 8:01 PM
|
7298 - Install New Nano Controller |
Instruction
|
Published
|
05/01/2023 8:24 AM
|
8895 - 7299 - Mount new Nano Controller; Remark:8892 |
Procedure Step
|
Published
|
09/25/2023 8:02 PM
|
7299 - Mount new Nano Controller |
Instruction
|
Published
|
05/01/2023 8:24 AM
|
8892 - Hook nano controller to top of mounting rail and rotate down. Nano controller... |
Remark
|
Published
|
09/25/2023 7:37 PM
|
8896 - 7300 - Reconnect occupancy output wire; Remark:7338 |
Procedure Step
|
Published
|
09/25/2023 9:37 PM
|
7263 - Caution : Correct placement of connectors and wiring is critical to proper operation. |
Annotation
|
Published
|
04/24/2023 2:32 PM
|
7300 - Reconnect occupancy output wire |
Instruction
|
Published
|
05/01/2023 8:26 AM
|
7338 - Insert green wire in Q1 terminal. Use a small slotted screwdriver. |
Remark
|
Published
|
05/03/2023 10:48 AM
|
8897 - 7301 - Reconnect power wires; Remark:7339 |
Procedure Step
|
Published
|
09/25/2023 8:04 PM
|
7301 - Reconnect power wires |
Instruction
|
Published
|
05/01/2023 8:26 AM
|
7339 - Use a small slotted screwdriver to reconnect existing power wires on terminal... |
Remark
|
Published
|
09/25/2023 7:48 PM
|
8898 - 7302 - Reconnect occupancy sensor wires; Remark:7340 |
Procedure Step
|
Published
|
09/25/2023 8:05 PM
|
7302 - Reconnect occupancy sensor wires |
Instruction
|
Published
|
05/01/2023 8:27 AM
|
7340 - Connect black wire from black infrared occupancy sensor to I1 |
Remark
|
Published
|
09/25/2023 7:53 PM
|
8899 - 7303 - Reconnect RJ-45 Ethernet cable; Remark:8893 |
Procedure Step
|
Published
|
09/25/2023 8:06 PM
|
7303 - Reconnect RJ-45 Ethernet cable |
Instruction
|
Published
|
05/01/2023 8:28 AM
|
8893 - Nano Controller RJ45 Connection |
Remark
|
Published
|
09/25/2023 7:57 PM
|
7279 - 7249 - Return equipment to normal operating condition; Remark: |
Procedure Step
|
Published
|
04/27/2023 4:13 PM
|
7249 - Return equipment to normal operating condition |
Instruction
|
Published
|
04/08/2025 3:22 PM
|
7280 - 7250 - Power on RPM; Remark:7251 |
Procedure Step
|
Published
|
04/27/2023 4:14 PM
|
7250 - Power on RPM |
Instruction
|
Published
|
05/01/2023 8:31 AM
|
7251 - Move LD-260 switch to ON position. The LED PWR ON |
Remark
|
Published
|
05/10/2023 3:14 PM
|
7281 - 7252 - Verify RPM start-up; Remark:7253 |
Procedure Step
|
Published
|
04/20/2025 3:26 PM
|
7252 - Verify RPM start-up |
Instruction
|
Published
|
04/27/2023 2:23 PM
|
7253 - RPM will perform a power on self-test (POST) and collect a background radiati... |
Remark
|
Published
|
05/10/2023 3:14 PM
|
8506 - 7254 - Confirm network connection; Remark:7255 |
Procedure Step
|
Published
|
09/24/2023 3:34 PM
|
7254 - Confirm network connection |
Instruction
|
Published
|
04/27/2023 2:22 PM
|
7255 - Contact operators to confirm communications have been reestablished between RPM ... |
Remark
|
Published
|
05/10/2023 3:15 PM
|
8588 - 7305 - Enable both infrared occupancy sensors; Remark:8559 |
Procedure Step
|
Published
|
09/17/2023 11:04 PM
|
5553 - Caution : Correct placement of connectors and wiring is critical to proper operation. |
Annotation
|
Published
|
10/28/2022 2:19 PM
|
7305 - Enable both infrared occupancy sensors |
Instruction
|
Published
|
05/01/2023 8:33 AM
|
8559 - To reconnect sensor cable, align connectors, push towards sensor, and turn co... |
Remark
|
Published
|
09/29/2023 12:05 PM
|
8433 - 8432 - Close all RPM doors; Remark: |
Procedure Step
|
Published
|
09/14/2023 9:14 AM
|
8432 - Close all RPM doors |
Instruction
|
Published
|
09/14/2023 9:14 AM
|
8434 - 8431 - Generate speed message; Remark:8430 |
Procedure Step
|
Published
|
09/14/2023 9:15 AM
|
8431 - Generate speed message |
Instruction
|
Published
|
09/14/2023 9:14 AM
|
8430 - Stand to side of control pillar. Open door with infrared sensors. |
Remark
|
Published
|
09/14/2023 9:15 AM
|
8606 - 7308 - Verify Nano Controller response; Remark:8599 |
Procedure Step
|
Published
|
09/18/2023 12:49 PM
|
7308 - Verify Nano Controller response |
Instruction
|
Published
|
05/01/2023 8:35 AM
|
8599 - Nano Controller LEDs will illuminate (IN1, IN2 |
Remark
|
Published
|
09/18/2023 12:36 PM
|
8437 - 8425 - Verify speed message in CAS; Remark:8424 |
Procedure Step
|
Published
|
09/14/2023 9:37 AM
|
8425 - Verify speed message in CAS |
Instruction
|
Published
|
09/14/2023 9:36 AM
|
8424 - Contact CAS operator to verify “SP” appears in RAVEN [Radiation Alarm and... |
Remark
|
Published
|
09/14/2023 9:37 AM
|
8589 - 7310 - Enable tamper switches; Remark:7348 |
Procedure Step
|
Published
|
09/17/2023 11:07 PM
|
7310 - Enable tamper switches |
Instruction
|
Published
|
05/01/2023 8:36 AM
|
7348 - Remove all magnets and/or adhesive tape from door switches. |
Remark
|
Published
|
09/17/2023 10:23 PM
|
8507 - 7256 - Close and lock all RPM doors; Remark: |
Procedure Step
|
Published
|
09/24/2023 3:35 PM
|
7256 - Close and lock all RPM doors |
Instruction
|
Published
|
04/27/2023 2:21 PM
|
7842 - 7820 - Inform system operators upon completion of maintenance action; Remark: |
Procedure Step
|
Published
|
07/07/2023 11:15 PM
|
7820 - Inform system operators upon completion of maintenance action |
Instruction
|
Published
|
07/07/2023 10:02 PM
|
322 - 321 - Document maintenance actions; Remark: |
Procedure Step
|
Published
|
06/17/2021 9:49 AM
|
321 - Document maintenance actions |
Instruction
|
Published
|
04/21/2025 11:19 AM
|
2869 - 2585 - Document maintenance performed; Remark:2866 |
Procedure Step
|
Published
|
06/18/2021 5:58 PM
|
2585 - Document maintenance performed |
Instruction
|
Published
|
07/09/2021 12:15 PM
|
2866 - Record observations, times, and results for the maintenance report. |
Remark
|
Published
|
04/21/2025 11:39 AM
|
4706 - 4705 - Submit report; Remark:4864 |
Procedure Step
|
Published
|
06/29/2022 9:50 AM
|
4705 - Submit report |
Instruction
|
Published
|
06/29/2022 9:50 AM
|
4864 - As specified by management or contractual obligations. |
Remark
|
Published
|
07/28/2022 1:36 PM
|
Corrective Maintenance Procedure |
Document Type
|
Published
|
03/02/2020 3:32 PM
|
Upon failure of Nano Controller |
Frequency
|
Published
|
09/25/2023 8:49 PM
|
Warning |
Annotation Type
|
Published
|
03/02/2020 3:25 PM
|
Note |
Annotation Type
|
Published
|
03/02/2020 3:25 PM
|
Caution |
Annotation Type
|
Published
|
03/02/2020 3:24 PM
|
Technician 2 |
Skill Level
|
Published
|
04/09/2020 1:17 AM
|
Keys to access RPM |
Replacement Parts
|
Published
|
04/27/2023 6:56 PM
|
Magnets and adhesive tape to disable door tamper switches |
Replacement Parts
|
Published
|
06/02/2023 10:08 PM
|
Medium Phillips (PH2) screwdriver |
Tools
|
Published
|
04/24/2020 4:40 PM
|
Small slotted (flathead) screwdriver |
Tools
|
Published
|
09/11/2020 11:23 AM
|
Orange/yellow safety vest |
Replacement Parts
|
Published
|
04/27/2023 6:56 PM
|
Safety shoes |
Replacement Parts
|
Published
|
04/27/2023 6:56 PM
|
Gloves |
Replacement Parts
|
Published
|
05/10/2023 3:28 PM
|
Protective headwear: glasses, hard hat |
Replacement Parts
|
Published
|
05/10/2023 3:31 PM
|
Orange traffic cones |
Replacement Parts
|
Published
|
04/27/2023 6:56 PM
|
Disable tamper switch |
படம்
|
Published
|
09/07/2023 8:22 PM
|
Disable Tamper Switch |
படம்
|
Published
|
06/02/2023 2:28 PM
|
Infrared Receiver |
படம்
|
Published
|
09/17/2023 7:09 PM
|
Infrared Receiver DC |
படம்
|
Published
|
09/29/2023 11:47 AM
|
Infrared Disconnect Sensor Cable |
படம்
|
Published
|
09/17/2023 7:11 PM
|
Infrared Sensor Disconnect |
படம்
|
Published
|
09/17/2023 7:12 PM
|
nanocontroller - Disconnect RJ-45 Ethernet cable |
படம்
|
Published
|
09/12/2023 10:40 AM
|
Disconnect occupancy sensor wires |
படம்
|
Published
|
09/12/2023 10:50 AM
|
Disconnect power wires |
படம்
|
Published
|
09/12/2023 10:52 AM
|
Disconnect occupancy output wire |
படம்
|
Published
|
09/12/2023 10:55 AM
|
Remove Nano Controller |
படம்
|
Published
|
09/12/2023 11:07 AM
|
Remove Nano Controller 2 |
படம்
|
Published
|
09/12/2023 11:08 AM
|
Install Nano Controller |
படம்
|
Published
|
09/25/2023 7:36 PM
|
Nano Controller Output Wire |
படம்
|
Published
|
09/25/2023 9:33 PM
|
Power to Nano Controller |
படம்
|
Published
|
09/25/2023 7:47 PM
|
Connect Occupancy Sensor Wires |
படம்
|
Published
|
09/25/2023 7:53 PM
|
Connect RJ45 in Nano Controller |
படம்
|
Published
|
09/25/2023 7:56 PM
|
LD-260 Disconnect Switch Power On |
படம்
|
Published
|
05/04/2023 3:37 PM
|
Infrared Connection |
படம்
|
Published
|
09/29/2023 12:02 PM
|
Infrared Cable Installation |
படம்
|
Published
|
09/17/2023 10:12 PM
|
Infrared Sensor Cable |
படம்
|
Published
|
09/17/2023 10:13 PM
|
Open door with infrared sensors |
படம்
|
Published
|
09/14/2023 9:01 AM
|
PLC Response |
படம்
|
Published
|
09/18/2023 12:35 PM
|
Remove all magnets and or adhesive tape from door switches |
படம்
|
Published
|
09/08/2023 4:18 PM
|
Remove Magnet on Tamper Switch |
படம்
|
Published
|
06/02/2023 4:31 PM
|