Rapiscan PM-700 Pedestrian Monitor |
Device
|
Published
|
06/20/2024 11:38 AM
|
Rapiscan VM-250 Vehicle Monitor |
Device
|
Published
|
10/14/2024 9:50 AM
|
Rapiscan TM-850 Rail Monitor |
Device
|
Published
|
09/18/2024 10:28 AM
|
7621 - 1401 - Establish Initial Conditions; Remark: |
Procedure Step
|
Published
|
06/29/2023 5:37 PM
|
1401 - Establish Initial Conditions |
Instruction
|
Published
|
09/30/2022 3:14 PM
|
7268 - 7231 - Close lane; Remark:7233 |
Procedure Step
|
Published
|
04/27/2023 7:01 PM
|
9053 - Warning : Traffic should temporarily be rerouted or halted during conduction of this pr... |
Annotation
|
Published
|
09/27/2023 9:09 AM
|
7231 - Close lane |
Instruction
|
Published
|
04/18/2023 1:00 PM
|
7233 - Use orange safety (traffic control) cones to setup barriers. Practice establi... |
Remark
|
Published
|
04/24/2023 12:18 PM
|
7269 - 7232 - Open RPM door; Remark:7234 |
Procedure Step
|
Published
|
04/27/2023 7:02 PM
|
7232 - Open RPM door |
Instruction
|
Published
|
04/18/2023 1:02 PM
|
7234 - Open all doors needed to access components. |
Remark
|
Published
|
04/19/2025 7:48 PM
|
7454 - 7290 - Disable tamper switches; Remark:7416 |
Procedure Step
|
Published
|
06/02/2023 5:25 PM
|
7290 - Disable tamper switches |
Instruction
|
Published
|
05/01/2023 8:14 AM
|
7416 - Use a magnet to disable tamper switches for all open doors. Use adhesive tape... |
Remark
|
Published
|
06/02/2023 1:18 PM
|
8281 - 8280 - Disable both infrared occupancy sensors; Remark:8279 |
Procedure Step
|
Published
|
09/07/2023 8:39 PM
|
7351 - Note : It is good practice to verify all cables and connectors are labeled prior to ... |
Annotation
|
Published
|
05/03/2023 11:25 AM
|
8280 - Disable both infrared occupancy sensors |
Instruction
|
Published
|
09/07/2023 8:31 PM
|
8279 - Verify sensors mounted in control pillar door are receivers |
Remark
|
Published
|
09/07/2023 8:39 PM
|
8287 - To disconnect sensor cable, turn collar counterclockwise and pull away from s... |
Remark
|
Published
|
09/08/2023 12:34 PM
|
7270 - 7235 - Power off RPM; Remark:7236 |
Procedure Step
|
Published
|
09/01/2023 7:57 PM
|
7235 - Power off RPM |
Instruction
|
Published
|
04/24/2023 12:30 PM
|
7236 - Move LD-260 switch to OFF position. The PWR ON |
Remark
|
Published
|
04/27/2023 4:25 PM
|
8286 - 8285 - Uninstall VD-580; Remark: |
Procedure Step
|
Published
|
09/08/2023 12:39 PM
|
8285 - Uninstall VD-580 |
Instruction
|
Published
|
09/08/2023 12:38 PM
|
8284 - 8283 - Disconnect BNC and MHV cables; Remark:8282 |
Procedure Step
|
Published
|
09/08/2023 12:45 PM
|
7352 - Note : It is good practice to verify all cables and connectors are labeled prior to ... |
Annotation
|
Published
|
05/03/2023 11:27 AM
|
8283 - Disconnect BNC and MHV cables |
Instruction
|
Published
|
09/08/2023 12:40 PM
|
8282 - Push toward connection, turn coupling nut counterclockwise, and pull away fro... |
Remark
|
Published
|
09/08/2023 12:45 PM
|
8313 - 8311 - Remove three (3) mounting springs; Remark:8310 |
Procedure Step
|
Published
|
09/08/2023 2:28 PM
|
8312 - Note : Take care when removing springs, as they might snap back and become misplaced... |
Annotation
|
Published
|
09/08/2023 2:28 PM
|
8311 - Remove three (3) mounting springs |
Instruction
|
Published
|
09/08/2023 2:22 PM
|
8310 - Use needle nose pliers. Retain springs for reinstallation. |
Remark
|
Published
|
09/08/2023 2:28 PM
|
8314 - 8309 - Remove VD-580; Remark:8308 |
Procedure Step
|
Published
|
09/08/2023 2:41 PM
|
8309 - Remove VD-580 |
Instruction
|
Published
|
09/08/2023 2:31 PM
|
8308 - Pull VD-580, using small side-to-side motion. |
Remark
|
Published
|
09/08/2023 2:40 PM
|
8307 - 8306 - Uninstall faulty gamma detector; Remark: |
Procedure Step
|
Published
|
09/08/2023 2:45 PM
|
8306 - Uninstall faulty gamma detector |
Instruction
|
Published
|
09/08/2023 2:45 PM
|
8302 - 8301 - Remove metal brackets; Remark:8300 |
Procedure Step
|
Published
|
09/08/2023 2:52 PM
|
8301 - Remove metal brackets |
Instruction
|
Published
|
09/08/2023 2:47 PM
|
8300 - Use small Phillips (PH1) screwdriver. Retain brackets and screws |
Remark
|
Published
|
09/08/2023 2:51 PM
|
8303 - 8298 - Remove securing straps; Remark:8297 |
Procedure Step
|
Published
|
09/08/2023 3:00 PM
|
8299 - Caution : Detector may fall out of lead shielding when brackets and straps are removed.... |
Annotation
|
Published
|
09/08/2023 3:00 PM
|
8298 - Remove securing straps |
Instruction
|
Published
|
09/08/2023 2:54 PM
|
8297 - Do NOT cut straps. Straps may be hook and loop (Velcro) or cable ties. Some w... |
Remark
|
Published
|
09/08/2023 2:59 PM
|
8304 - 8296 - Remove faulty gamma detector; Remark:8295 |
Procedure Step
|
Published
|
09/08/2023 3:06 PM
|
8296 - Remove faulty gamma detector |
Instruction
|
Published
|
09/08/2023 3:00 PM
|
8295 - |
Remark
|
Published
|
09/08/2023 3:06 PM
|
3397 - 3395 - Label faulty component; Remark:3396 |
Procedure Step
|
Published
|
07/21/2024 6:59 AM
|
3395 - Label faulty component |
Instruction
|
Published
|
08/07/2021 11:07 AM
|
3396 - Use tag or tape. Include date of removal, description of failure symptoms, co... |
Remark
|
Published
|
08/09/2021 11:35 AM
|
8292 - 8291 - Install new gamma detector; Remark: |
Procedure Step
|
Published
|
09/08/2023 3:10 PM
|
8291 - Install new gamma detector |
Instruction
|
Published
|
09/08/2023 3:10 PM
|
8290 - 8289 - Set new gamma detector in place; Remark:8288 |
Procedure Step
|
Published
|
09/08/2023 3:24 PM
|
8289 - Set new gamma detector in place |
Instruction
|
Published
|
09/08/2023 3:15 PM
|
8288 - |
Remark
|
Published
|
09/08/2023 3:24 PM
|
8333 - 8332 - Fasten securing straps; Remark:8331 |
Procedure Step
|
Published
|
09/08/2023 3:31 PM
|
8332 - Fasten securing straps |
Instruction
|
Published
|
09/08/2023 3:30 PM
|
8331 - Use hook and loop (Velcro) straps or long, heavy-duty cable ties. If cable ti... |
Remark
|
Published
|
09/08/2023 3:31 PM
|
8334 - 8330 - Replace metal brackets; Remark:472 |
Procedure Step
|
Published
|
09/08/2023 3:37 PM
|
8330 - Replace metal brackets |
Instruction
|
Published
|
09/08/2023 3:31 PM
|
472 - Use a small Phillips (PH1) screwdriver. |
Remark
|
Published
|
07/22/2021 1:13 PM
|
8329 - 8328 - Install VD-580; Remark: |
Procedure Step
|
Published
|
09/08/2023 3:41 PM
|
8328 - Install VD-580 |
Instruction
|
Published
|
09/08/2023 3:41 PM
|
8325 - 8324 - Reconnect VD-580 to photomultiplier tube; Remark:8323 |
Procedure Step
|
Published
|
09/08/2023 3:47 PM
|
8324 - Reconnect VD-580 to photomultiplier tube |
Instruction
|
Published
|
09/08/2023 3:42 PM
|
8323 - The VD-580 has a notch that aligns with the tab on the photomultiplier tube |
Remark
|
Published
|
09/08/2023 3:47 PM
|
8326 - 8322 - Reattach mounting springs; Remark:9071 |
Procedure Step
|
Published
|
09/08/2023 3:50 PM
|
8322 - Reattach mounting springs |
Instruction
|
Published
|
09/08/2023 3:48 PM
|
9071 - Use needle nose pliers. |
Remark
|
Published
|
09/27/2023 9:58 AM
|
8327 - 8320 - Reconnect BNC and MHV cables; Remark:8319 |
Procedure Step
|
Published
|
09/08/2023 3:56 PM
|
5553 - Caution : Correct placement of connectors and wiring is critical to proper operation. |
Annotation
|
Published
|
10/28/2022 2:19 PM
|
8320 - Reconnect BNC and MHV cables |
Instruction
|
Published
|
09/08/2023 3:55 PM
|
8319 - Ensure cables are connected correctly. Connector placement should not require... |
Remark
|
Published
|
09/08/2023 3:56 PM
|
7279 - 7249 - Return equipment to normal operating condition; Remark: |
Procedure Step
|
Published
|
04/27/2023 4:13 PM
|
7249 - Return equipment to normal operating condition |
Instruction
|
Published
|
04/08/2025 3:22 PM
|
7280 - 7250 - Power on RPM; Remark:7251 |
Procedure Step
|
Published
|
04/27/2023 4:14 PM
|
7250 - Power on RPM |
Instruction
|
Published
|
05/01/2023 8:31 AM
|
7251 - Move LD-260 switch to ON position. The LED PWR ON |
Remark
|
Published
|
05/10/2023 3:14 PM
|
7468 - 7304 - Confirm RPM has restarted correctly; Remark:7487 |
Procedure Step
|
Published
|
06/02/2023 5:36 PM
|
7304 - Confirm RPM has restarted correctly |
Instruction
|
Published
|
05/01/2023 8:31 AM
|
7487 - The SC-770 controller will display "OK" following Power On Self-Test (POST) a... |
Remark
|
Published
|
06/02/2023 10:35 PM
|
7469 - 7254 - Confirm network connection; Remark:7255 |
Procedure Step
|
Published
|
06/02/2023 5:36 PM
|
7254 - Confirm network connection |
Instruction
|
Published
|
04/27/2023 2:22 PM
|
7255 - Contact operators to confirm communications have been reestablished between RPM ... |
Remark
|
Published
|
05/10/2023 3:15 PM
|
7840 - 7816 - Perform electronic alignment; Remark:7817 |
Procedure Step
|
Published
|
07/07/2023 11:12 PM
|
7816 - Perform electronic alignment |
Instruction
|
Published
|
07/07/2023 9:55 PM
|
7817 - DET-RPM-RAP-CM01, RPM Electronic Alignment Procedure. |
Remark
|
Published
|
04/13/2025 5:55 PM
|
8317 - 8316 - Enable both infrared occupancy sensors; Remark:8315 |
Procedure Step
|
Published
|
09/08/2023 4:14 PM
|
7263 - Caution : Correct placement of connectors and wiring is critical to proper operation. |
Annotation
|
Published
|
04/24/2023 2:32 PM
|
8316 - Enable both infrared occupancy sensors |
Instruction
|
Published
|
09/08/2023 4:11 PM
|
8315 - To reconnect sensor cable, align connectors, push towards sensor, and turn th... |
Remark
|
Published
|
09/08/2023 4:13 PM
|
8318 - 7450 - Enable tamper switches; Remark:7348 |
Procedure Step
|
Published
|
09/08/2023 4:20 PM
|
7450 - Enable tamper switches |
Instruction
|
Published
|
06/02/2023 4:42 PM
|
7348 - Remove all magnets and/or adhesive tape from door switches. |
Remark
|
Published
|
09/17/2023 10:23 PM
|
7283 - 7256 - Close and lock all RPM doors; Remark: |
Procedure Step
|
Published
|
09/01/2023 11:45 PM
|
7256 - Close and lock all RPM doors |
Instruction
|
Published
|
04/27/2023 2:21 PM
|
7842 - 7820 - Inform system operators upon completion of maintenance action; Remark: |
Procedure Step
|
Published
|
07/07/2023 11:15 PM
|
7820 - Inform system operators upon completion of maintenance action |
Instruction
|
Published
|
07/07/2023 10:02 PM
|
322 - 321 - Document maintenance actions; Remark: |
Procedure Step
|
Published
|
06/17/2021 9:49 AM
|
321 - Document maintenance actions |
Instruction
|
Published
|
04/21/2025 11:19 AM
|
2869 - 2585 - Document maintenance performed; Remark:2866 |
Procedure Step
|
Published
|
06/18/2021 5:58 PM
|
2585 - Document maintenance performed |
Instruction
|
Published
|
07/09/2021 12:15 PM
|
2866 - Record observations, times, and results for the maintenance report. |
Remark
|
Published
|
04/21/2025 11:39 AM
|
4706 - 4705 - Submit report; Remark:4864 |
Procedure Step
|
Published
|
06/29/2022 9:50 AM
|
4705 - Submit report |
Instruction
|
Published
|
06/29/2022 9:50 AM
|
4864 - As specified by management or contractual obligations. |
Remark
|
Published
|
07/28/2022 1:36 PM
|
Corrective Maintenance Procedure |
Document Type
|
Published
|
03/02/2020 3:32 PM
|
minutes |
Duration
|
Published
|
05/26/2022 11:41 AM
|
Upon failure of the gamma detector |
Frequency
|
Published
|
09/07/2023 7:35 PM
|
Warning |
Annotation Type
|
Published
|
03/02/2020 3:25 PM
|
Note |
Annotation Type
|
Published
|
03/02/2020 3:25 PM
|
Caution |
Annotation Type
|
Published
|
03/02/2020 3:24 PM
|
Technician 2 |
Skill Level
|
Published
|
04/09/2020 1:17 AM
|
Keys to access RPM |
Replacement Parts
|
Published
|
04/27/2023 6:56 PM
|
Magnets and adhesive tape to disable door tamper switches |
Replacement Parts
|
Published
|
06/02/2023 10:08 PM
|
Needle nose pliers |
Tools
|
Published
|
05/06/2020 4:10 PM
|
Small Phillips (PH1) screwdriver |
Tools
|
Published
|
05/14/2020 2:48 PM
|
Ladder: 2 meters, 6 feet tall; non-conducting |
Replacement Parts
|
Published
|
09/01/2023 9:34 PM
|
Orange/yellow safety vest |
Replacement Parts
|
Published
|
04/27/2023 6:56 PM
|
Safety shoes |
Replacement Parts
|
Published
|
04/27/2023 6:56 PM
|
Gloves |
Replacement Parts
|
Published
|
05/10/2023 3:28 PM
|
Protective headwear: glasses, hard hat |
Replacement Parts
|
Published
|
05/10/2023 3:31 PM
|
Orange traffic cones |
Replacement Parts
|
Published
|
04/27/2023 6:56 PM
|
Disable tamper switch |
படம்
|
Published
|
09/07/2023 8:22 PM
|
Disable Tamper Switch |
படம்
|
Published
|
06/02/2023 2:28 PM
|
infrared sensor receiver |
படம்
|
Published
|
09/07/2023 8:37 PM
|
occupancy sensor receiver |
படம்
|
Published
|
09/07/2023 8:38 PM
|
Disconnect sensor cable |
படம்
|
Published
|
09/08/2023 12:27 PM
|
Pull cable away from sensor |
படம்
|
Published
|
09/08/2023 12:33 PM
|
LD-260 Disconnect Switch Power Off |
படம்
|
Published
|
04/24/2023 12:49 PM
|
Disconnect BNC and MHV cables |
படம்
|
Published
|
09/08/2023 12:44 PM
|
Remove three mounting springs |
படம்
|
Published
|
09/08/2023 2:26 PM
|
Remove VD-580 |
படம்
|
Published
|
09/08/2023 2:38 PM
|
Remove metal brackets |
படம்
|
Published
|
09/08/2023 2:50 PM
|
Remove metal brackets 2 |
படம்
|
Published
|
09/08/2023 2:51 PM
|
Remove securing straps |
படம்
|
Published
|
09/08/2023 2:58 PM
|
Remove faulty gamma detector |
படம்
|
Published
|
09/08/2023 3:02 PM
|
Remove faulty gamma detector 2 |
படம்
|
Published
|
09/08/2023 3:05 PM
|
Set new gamma detector in place |
படம்
|
Published
|
09/08/2023 3:17 PM
|
Reconnect VD-580 |
படம்
|
Published
|
09/08/2023 3:45 PM
|
Reconnect VD-580 (2) |
படம்
|
Published
|
09/08/2023 3:47 PM
|
Reattach mounting springs |
படம்
|
Published
|
09/27/2023 9:57 AM
|
Reconnect BNC and MHV cables |
படம்
|
Published
|
09/08/2023 3:54 PM
|
Reconnect BNC and MHV cables 2 |
படம்
|
Published
|
09/08/2023 3:54 PM
|
LD-260 Disconnect Switch Power On |
படம்
|
Published
|
05/04/2023 3:37 PM
|
reconnect occupancy sensors |
படம்
|
Published
|
09/08/2023 4:06 PM
|
reconnect occupancy sensors 2 |
படம்
|
Published
|
09/08/2023 4:08 PM
|
reconnect occupancy sensors 3 |
படம்
|
Published
|
09/08/2023 4:10 PM
|
Remove all magnets and or adhesive tape from door switches |
படம்
|
Published
|
09/08/2023 4:18 PM
|
Remove Magnet on Tamper Switch |
படம்
|
Published
|
06/02/2023 4:31 PM
|