RPM Operational Test

Last Updated: 04/24/2025 1:44 AM

The following table lists all the components that make up the document.

Title Type Status Last Updated
Rapiscan CM-267 Conveyor Monitor
Device
Published
06/27/2024 1:02 PM
Rapiscan PM-700 Pedestrian Monitor
Device
Published
06/20/2024 11:38 AM
Rapiscan TM-850 Rail Monitor
Device
Published
09/18/2024 10:28 AM
Rapiscan VM-250 Vehicle Monitor
Device
Published
10/14/2024 9:50 AM
1402 - 7927 - Establish Initial Conditions; Remark:
Procedure Step
Published
09/30/2022 1:47 PM
7927 - Establish Initial Conditions
Instruction
Published
07/12/2023 12:23 AM
7977 - 7592 - Inform system operators; Remark:7976
Procedure Step
Published
07/24/2023 9:53 AM
7592 - Inform system operators
Instruction
Published
06/29/2023 3:20 PM
7976 - Operators should expect to receive fault and alarm indications during perform...
Remark
Published
07/24/2023 9:53 AM
7983 - 7981 - Inspect for any physical damage or rodent/insect infestation; Remark:
Procedure Step
Published
07/26/2023 2:45 PM
7982 - Note : Document each step and verification on attached checklist
Annotation
Published
07/26/2023 2:45 PM
7981 - Inspect for any physical damage or rodent/insect infestation
Instruction
Published
07/26/2023 2:44 PM
7984 - 7980 - Close lane and set up barriers or establish a safety watch; Remark:7595
Procedure Step
Published
07/26/2023 2:47 PM
7678 - Warning : Traffic should temporarily be rerouted or halted during conduction of this pr...
Annotation
Published
07/03/2023 10:23 AM
7980 - Close lane and set up barriers or establish a safety watch
Instruction
Published
07/26/2023 2:46 PM
7595 - Use orange safety (traffic control) cones or equivalent per site-specific saf...
Remark
Published
06/29/2023 3:33 PM
7280 - 7250 - Power on RPM; Remark:7251
Procedure Step
Published
04/27/2023 4:14 PM
7250 - Power on RPM
Instruction
Published
05/01/2023 8:31 AM
7251 - Move LD-260 switch to ON position. The LED PWR ON
Remark
Published
05/10/2023 3:14 PM
7997 - 7995 - Disable RPM occupancy sensors; Remark:7994
Procedure Step
Published
07/26/2023 3:08 PM
7995 - Disable RPM occupancy sensors
Instruction
Published
07/26/2023 3:07 PM
7994 - “Relays” Parameter in SC-770 controller must be set to “ON.” Audible ...
Remark
Published
07/26/2023 3:07 PM
7993 - 7992 - Test Gamma Radiation Detection; Remark:
Procedure Step
Published
07/26/2023 3:33 PM
7992 - Test Gamma Radiation Detection
Instruction
Published
07/26/2023 3:33 PM
7989 - 7988 - Initiate and maintain occupancy by interrupting beam of occupancy sensor ...; Remark:
Procedure Step
Published
07/26/2023 3:37 PM
7988 - Initiate and maintain occupancy by interrupting beam of occupancy sensor ...
Instruction
Published
07/26/2023 3:34 PM
7990 - 7987 - Hold Cs-137 source, Co-57 source, or both near front of either gamma detector...; Remark:
Procedure Step
Published
07/26/2023 3:38 PM
7987 - Hold Cs-137 source, Co-57 source, or both near front of either gamma detector...
Instruction
Published
07/26/2023 3:38 PM
7991 - 7986 - Verify red strobe and audible indications function; Remark:7985
Procedure Step
Published
07/26/2023 3:38 PM
7986 - Verify red strobe and audible indications function
Instruction
Published
07/26/2023 3:38 PM
7985 - On SC-770 controller On the control pillar door
Remark
Published
07/26/2023 3:39 PM
8006 - 8004 - Remove Cs-137 source, Co-57 source, or both from detector; Remark:
Procedure Step
Published
07/26/2023 3:45 PM
8005 - Note : Move the source at least 10m from the detectors.
Annotation
Published
07/26/2023 3:45 PM
8004 - Remove Cs-137 source, Co-57 source, or both from detector
Instruction
Published
07/26/2023 3:45 PM
8007 - 8003 - Wait at least 30 seconds for background average to stabilize; Remark:
Procedure Step
Published
07/26/2023 3:46 PM
8003 - Wait at least 30 seconds for background average to stabilize
Instruction
Published
07/26/2023 3:46 PM
8008 - 8002 - Initiate a gamma hi background fault by holding Cs-137 source, Co 57 source, ...; Remark:
Procedure Step
Published
07/26/2023 3:47 PM
8002 - Initiate a gamma hi background fault by holding Cs-137 source, Co 57 source, ...
Instruction
Published
07/26/2023 3:47 PM
8009 - 8001 - Verify amber fault LED indication functions; Remark:8000
Procedure Step
Published
07/26/2023 3:49 PM
8001 - Verify amber fault LED indication functions
Instruction
Published
07/26/2023 3:48 PM
8000 - On SC-770 controller On the control pillar door
Remark
Published
04/13/2025 5:56 PM
8010 - 7998 - Remove Cs-137 source, Co-57 source, or both from detector; Remark:
Procedure Step
Published
07/26/2023 3:52 PM
7999 - Note : Move the source at least 10m from the detectors.
Annotation
Published
07/26/2023 3:52 PM
7998 - Remove Cs-137 source, Co-57 source, or both from detector
Instruction
Published
07/26/2023 3:51 PM
8015 - 8014 - Wait at least 30 seconds for background average to stabilize; Remark:
Procedure Step
Published
07/26/2023 3:54 PM
8014 - Wait at least 30 seconds for background average to stabilize
Instruction
Published
07/26/2023 3:54 PM
8016 - 8012 - Disconnect BNC signal cable from any gamma detector to initiate a gamma lo ba...; Remark:8011
Procedure Step
Published
07/26/2023 3:55 PM
8013 - Note : Occupancy sensors must be disabled during testing of fault indications.
Annotation
Published
07/26/2023 3:56 PM
8012 - Disconnect BNC signal cable from any gamma detector to initiate a gamma lo ba...
Instruction
Published
07/26/2023 3:54 PM
8011 - This can be done on the detector itself or at the SCA‐775 box.
Remark
Published
07/26/2023 3:55 PM
8030 - 8001 - Verify amber fault LED indication functions; Remark:7985
Procedure Step
Published
07/26/2023 4:18 PM
8031 - 8003 - Wait at least 30 seconds for background average to stabilize; Remark:
Procedure Step
Published
07/26/2023 4:19 PM
8032 - 8029 - Reconnect BNC signal cable from step 2-10; Remark:
Procedure Step
Published
07/26/2023 4:20 PM
8029 - Reconnect BNC signal cable from step 2-10
Instruction
Published
07/26/2023 4:19 PM
8028 - 8027 - Test Neutron Radiation Detection; Remark:
Procedure Step
Published
07/26/2023 4:21 PM
8027 - Test Neutron Radiation Detection
Instruction
Published
07/26/2023 4:21 PM
8022 - 7988 - Initiate and maintain occupancy by interrupting beam of occupancy sensor ...; Remark:
Procedure Step
Published
07/26/2023 4:22 PM
8021 - Note : Because CF-252 sources also emit gamma radiation, a gamma alarm may also occu...
Annotation
Published
07/26/2023 4:22 PM
8023 - 8020 - Hold Cf-252 source near front of neutron detector; Remark:
Procedure Step
Published
07/26/2023 4:23 PM
8020 - Hold Cf-252 source near front of neutron detector
Instruction
Published
07/26/2023 4:23 PM
8024 - 8019 - Verify blue strobe and audible indication functions; Remark:7985
Procedure Step
Published
07/26/2023 4:27 PM
8019 - Verify blue strobe and audible indication functions
Instruction
Published
07/26/2023 4:24 PM
8025 - 8018 - Remove Cf-252 source from detector; Remark:
Procedure Step
Published
07/26/2023 4:29 PM
8018 - Remove Cf-252 source from detector
Instruction
Published
07/26/2023 4:28 PM
8026 - 8017 - Wait at least 2 minutes for background average to stabilize; Remark:
Procedure Step
Published
07/26/2023 4:30 PM
8017 - Wait at least 2 minutes for background average to stabilize
Instruction
Published
07/26/2023 4:30 PM
8035 - 8033 - Initiate a neutron hi background fault by holding Cf‐252 source near front ...; Remark:
Procedure Step
Published
07/26/2023 4:32 PM
8034 - Note : A gamma hi fault may also occur during this step. If this is unacceptable, ei...
Annotation
Published
07/26/2023 4:32 PM
8033 - Initiate a neutron hi background fault by holding Cf‐252 source near front ...
Instruction
Published
07/26/2023 4:32 PM
8036 - 8001 - Verify amber fault LED indication functions; Remark:7985
Procedure Step
Published
07/26/2023 4:33 PM
8037 - 8018 - Remove Cf-252 source from detector; Remark:
Procedure Step
Published
07/26/2023 4:34 PM
8044 - 8043 - Test Tamper Fault Circuitry; Remark:
Procedure Step
Published
07/27/2023 8:54 AM
8043 - Test Tamper Fault Circuitry
Instruction
Published
07/27/2023 8:50 AM
8041 - 8040 - Disconnect the AC power supplied to the portal monitor to initiate a “Loss ...; Remark:8039
Procedure Step
Published
07/27/2023 8:57 AM
8040 - Disconnect the AC power supplied to the portal monitor to initiate a “Loss ...
Instruction
Published
07/27/2023 8:55 AM
8039 - 1.If RPM breaker in associated utility panel is marked: Open the RPMs dedicat...
Remark
Published
07/27/2023 8:57 AM
8042 - 8038 - Re-energize RPM, remove magnet from door switch, close cabinet door, and allo...; Remark:
Procedure Step
Published
07/27/2023 8:58 AM
8038 - Re-energize RPM, remove magnet from door switch, close cabinet door, and allo...
Instruction
Published
07/27/2023 8:58 AM
8051 - 8050 - Initiate a cabinet open tamper fault; Remark:
Procedure Step
Published
07/27/2023 9:00 AM
8050 - Initiate a cabinet open tamper fault
Instruction
Published
07/27/2023 9:00 AM
7842 - 7820 - Inform system operators upon completion of maintenance action; Remark:
Procedure Step
Published
07/07/2023 11:15 PM
7820 - Inform system operators upon completion of maintenance action
Instruction
Published
07/07/2023 10:02 PM
253 - 242 - Document and report any unresolved problems; Remark:
Procedure Step
Published
06/22/2021 10:23 AM
242 - Document and report any unresolved problems
Instruction
Published
04/21/2025 11:45 AM
Routine Maintenance Procedure
Document Type
Published
03/02/2020 3:31 PM
10 minutes
Duration
Published
04/01/2020 11:35 AM
Quarterly
Frequency
Published
08/02/2020 10:39 PM
Note
Annotation Type
Published
03/02/2020 3:25 PM
Warning
Annotation Type
Published
03/02/2020 3:25 PM
Technician 1
Skill Level
Published
05/14/2020 2:56 PM
Keys to access RPM
Replacement Parts
Published
04/27/2023 6:56 PM
Reflective safety vest if required
Replacement Parts
Published
06/20/2023 4:47 PM
Traffic control cones or equivalent if required
Replacement Parts
Published
06/20/2023 4:47 PM
Magnet
Replacement Parts
Published
07/24/2023 9:53 AM
LD-260 Disconnect Switch Power On
படம்
Published
05/04/2023 3:37 PM