Rapiscan CM-267 Conveyor Monitor |
Device
|
Published
|
06/27/2024 1:02 PM
|
Rapiscan PM-700 Pedestrian Monitor |
Device
|
Published
|
06/20/2024 11:38 AM
|
Rapiscan TM-850 Rail Monitor |
Device
|
Published
|
09/18/2024 10:28 AM
|
Rapiscan VM-250 Vehicle Monitor |
Device
|
Published
|
10/14/2024 9:50 AM
|
1402 - 7927 - Establish Initial Conditions; Remark: |
Procedure Step
|
Published
|
09/30/2022 1:47 PM
|
7927 - Establish Initial Conditions |
Instruction
|
Published
|
07/12/2023 12:23 AM
|
7977 - 7592 - Inform system operators; Remark:7976 |
Procedure Step
|
Published
|
07/24/2023 9:53 AM
|
7592 - Inform system operators |
Instruction
|
Published
|
06/29/2023 3:20 PM
|
7976 - Operators should expect to receive fault and alarm indications during perform... |
Remark
|
Published
|
07/24/2023 9:53 AM
|
7983 - 7981 - Inspect for any physical damage or rodent/insect infestation; Remark: |
Procedure Step
|
Published
|
07/26/2023 2:45 PM
|
7982 - Note : Document each step and verification on attached checklist |
Annotation
|
Published
|
07/26/2023 2:45 PM
|
7981 - Inspect for any physical damage or rodent/insect infestation |
Instruction
|
Published
|
07/26/2023 2:44 PM
|
7984 - 7980 - Close lane and set up barriers or establish a safety watch; Remark:7595 |
Procedure Step
|
Published
|
07/26/2023 2:47 PM
|
7678 - Warning : Traffic should temporarily be rerouted or halted during conduction of this pr... |
Annotation
|
Published
|
07/03/2023 10:23 AM
|
7980 - Close lane and set up barriers or establish a safety watch |
Instruction
|
Published
|
07/26/2023 2:46 PM
|
7595 - Use orange safety (traffic control) cones or equivalent per site-specific saf... |
Remark
|
Published
|
06/29/2023 3:33 PM
|
7280 - 7250 - Power on RPM; Remark:7251 |
Procedure Step
|
Published
|
04/27/2023 4:14 PM
|
7250 - Power on RPM |
Instruction
|
Published
|
05/01/2023 8:31 AM
|
7251 - Move LD-260 switch to ON position. The LED PWR ON |
Remark
|
Published
|
05/10/2023 3:14 PM
|
7997 - 7995 - Disable RPM occupancy sensors; Remark:7994 |
Procedure Step
|
Published
|
07/26/2023 3:08 PM
|
7995 - Disable RPM occupancy sensors |
Instruction
|
Published
|
07/26/2023 3:07 PM
|
7994 - “Relays” Parameter in SC-770 controller must be set to “ON.” Audible ... |
Remark
|
Published
|
07/26/2023 3:07 PM
|
7993 - 7992 - Test Gamma Radiation Detection; Remark: |
Procedure Step
|
Published
|
07/26/2023 3:33 PM
|
7992 - Test Gamma Radiation Detection |
Instruction
|
Published
|
07/26/2023 3:33 PM
|
7989 - 7988 - Initiate and maintain occupancy by interrupting beam of occupancy sensor ...; Remark: |
Procedure Step
|
Published
|
07/26/2023 3:37 PM
|
7988 - Initiate and maintain occupancy by interrupting beam of occupancy sensor ... |
Instruction
|
Published
|
07/26/2023 3:34 PM
|
7990 - 7987 - Hold Cs-137 source, Co-57 source, or both near front of either gamma detector...; Remark: |
Procedure Step
|
Published
|
07/26/2023 3:38 PM
|
7987 - Hold Cs-137 source, Co-57 source, or both near front of either gamma detector... |
Instruction
|
Published
|
07/26/2023 3:38 PM
|
7991 - 7986 - Verify red strobe and audible indications function; Remark:7985 |
Procedure Step
|
Published
|
07/26/2023 3:38 PM
|
7986 - Verify red strobe and audible indications function |
Instruction
|
Published
|
07/26/2023 3:38 PM
|
7985 - On SC-770 controller On the control pillar door |
Remark
|
Published
|
07/26/2023 3:39 PM
|
8006 - 8004 - Remove Cs-137 source, Co-57 source, or both from detector; Remark: |
Procedure Step
|
Published
|
07/26/2023 3:45 PM
|
8005 - Note : Move the source at least 10m from the detectors. |
Annotation
|
Published
|
07/26/2023 3:45 PM
|
8004 - Remove Cs-137 source, Co-57 source, or both from detector |
Instruction
|
Published
|
07/26/2023 3:45 PM
|
8007 - 8003 - Wait at least 30 seconds for background average to stabilize; Remark: |
Procedure Step
|
Published
|
07/26/2023 3:46 PM
|
8003 - Wait at least 30 seconds for background average to stabilize |
Instruction
|
Published
|
07/26/2023 3:46 PM
|
8008 - 8002 - Initiate a gamma hi background fault by holding Cs-137 source, Co 57 source, ...; Remark: |
Procedure Step
|
Published
|
07/26/2023 3:47 PM
|
8002 - Initiate a gamma hi background fault by holding Cs-137 source, Co 57 source, ... |
Instruction
|
Published
|
07/26/2023 3:47 PM
|
8009 - 8001 - Verify amber fault LED indication functions; Remark:8000 |
Procedure Step
|
Published
|
07/26/2023 3:49 PM
|
8001 - Verify amber fault LED indication functions |
Instruction
|
Published
|
07/26/2023 3:48 PM
|
8000 - On SC-770 controller On the control pillar door |
Remark
|
Published
|
04/13/2025 5:56 PM
|
8010 - 7998 - Remove Cs-137 source, Co-57 source, or both from detector; Remark: |
Procedure Step
|
Published
|
07/26/2023 3:52 PM
|
7999 - Note : Move the source at least 10m from the detectors. |
Annotation
|
Published
|
07/26/2023 3:52 PM
|
7998 - Remove Cs-137 source, Co-57 source, or both from detector |
Instruction
|
Published
|
07/26/2023 3:51 PM
|
8015 - 8014 - Wait at least 30 seconds for background average to stabilize; Remark: |
Procedure Step
|
Published
|
07/26/2023 3:54 PM
|
8014 - Wait at least 30 seconds for background average to stabilize |
Instruction
|
Published
|
07/26/2023 3:54 PM
|
8016 - 8012 - Disconnect BNC signal cable from any gamma detector to initiate a gamma lo ba...; Remark:8011 |
Procedure Step
|
Published
|
07/26/2023 3:55 PM
|
8013 - Note : Occupancy sensors must be disabled during testing of fault indications. |
Annotation
|
Published
|
07/26/2023 3:56 PM
|
8012 - Disconnect BNC signal cable from any gamma detector to initiate a gamma lo ba... |
Instruction
|
Published
|
07/26/2023 3:54 PM
|
8011 - This can be done on the detector itself or at the SCA‐775 box. |
Remark
|
Published
|
07/26/2023 3:55 PM
|
8030 - 8001 - Verify amber fault LED indication functions; Remark:7985 |
Procedure Step
|
Published
|
07/26/2023 4:18 PM
|
8031 - 8003 - Wait at least 30 seconds for background average to stabilize; Remark: |
Procedure Step
|
Published
|
07/26/2023 4:19 PM
|
8032 - 8029 - Reconnect BNC signal cable from step 2-10; Remark: |
Procedure Step
|
Published
|
07/26/2023 4:20 PM
|
8029 - Reconnect BNC signal cable from step 2-10 |
Instruction
|
Published
|
07/26/2023 4:19 PM
|
8028 - 8027 - Test Neutron Radiation Detection; Remark: |
Procedure Step
|
Published
|
07/26/2023 4:21 PM
|
8027 - Test Neutron Radiation Detection |
Instruction
|
Published
|
07/26/2023 4:21 PM
|
8022 - 7988 - Initiate and maintain occupancy by interrupting beam of occupancy sensor ...; Remark: |
Procedure Step
|
Published
|
07/26/2023 4:22 PM
|
8021 - Note : Because CF-252 sources also emit gamma radiation, a gamma alarm may also occu... |
Annotation
|
Published
|
07/26/2023 4:22 PM
|
8023 - 8020 - Hold Cf-252 source near front of neutron detector; Remark: |
Procedure Step
|
Published
|
07/26/2023 4:23 PM
|
8020 - Hold Cf-252 source near front of neutron detector |
Instruction
|
Published
|
07/26/2023 4:23 PM
|
8024 - 8019 - Verify blue strobe and audible indication functions; Remark:7985 |
Procedure Step
|
Published
|
07/26/2023 4:27 PM
|
8019 - Verify blue strobe and audible indication functions |
Instruction
|
Published
|
07/26/2023 4:24 PM
|
8025 - 8018 - Remove Cf-252 source from detector; Remark: |
Procedure Step
|
Published
|
07/26/2023 4:29 PM
|
8018 - Remove Cf-252 source from detector |
Instruction
|
Published
|
07/26/2023 4:28 PM
|
8026 - 8017 - Wait at least 2 minutes for background average to stabilize; Remark: |
Procedure Step
|
Published
|
07/26/2023 4:30 PM
|
8017 - Wait at least 2 minutes for background average to stabilize |
Instruction
|
Published
|
07/26/2023 4:30 PM
|
8035 - 8033 - Initiate a neutron hi background fault by holding Cf‐252 source near front ...; Remark: |
Procedure Step
|
Published
|
07/26/2023 4:32 PM
|
8034 - Note : A gamma hi fault may also occur during this step. If this is unacceptable, ei... |
Annotation
|
Published
|
07/26/2023 4:32 PM
|
8033 - Initiate a neutron hi background fault by holding Cf‐252 source near front ... |
Instruction
|
Published
|
07/26/2023 4:32 PM
|
8036 - 8001 - Verify amber fault LED indication functions; Remark:7985 |
Procedure Step
|
Published
|
07/26/2023 4:33 PM
|
8037 - 8018 - Remove Cf-252 source from detector; Remark: |
Procedure Step
|
Published
|
07/26/2023 4:34 PM
|
8044 - 8043 - Test Tamper Fault Circuitry; Remark: |
Procedure Step
|
Published
|
07/27/2023 8:54 AM
|
8043 - Test Tamper Fault Circuitry |
Instruction
|
Published
|
07/27/2023 8:50 AM
|
8041 - 8040 - Disconnect the AC power supplied to the portal monitor to initiate a “Loss ...; Remark:8039 |
Procedure Step
|
Published
|
07/27/2023 8:57 AM
|
8040 - Disconnect the AC power supplied to the portal monitor to initiate a “Loss ... |
Instruction
|
Published
|
07/27/2023 8:55 AM
|
8039 - 1.If RPM breaker in associated utility panel is marked: Open the RPMs dedicat... |
Remark
|
Published
|
07/27/2023 8:57 AM
|
8042 - 8038 - Re-energize RPM, remove magnet from door switch, close cabinet door, and allo...; Remark: |
Procedure Step
|
Published
|
07/27/2023 8:58 AM
|
8038 - Re-energize RPM, remove magnet from door switch, close cabinet door, and allo... |
Instruction
|
Published
|
07/27/2023 8:58 AM
|
8051 - 8050 - Initiate a cabinet open tamper fault; Remark: |
Procedure Step
|
Published
|
07/27/2023 9:00 AM
|
8050 - Initiate a cabinet open tamper fault |
Instruction
|
Published
|
07/27/2023 9:00 AM
|
7842 - 7820 - Inform system operators upon completion of maintenance action; Remark: |
Procedure Step
|
Published
|
07/07/2023 11:15 PM
|
7820 - Inform system operators upon completion of maintenance action |
Instruction
|
Published
|
07/07/2023 10:02 PM
|
253 - 242 - Document and report any unresolved problems; Remark: |
Procedure Step
|
Published
|
06/22/2021 10:23 AM
|
242 - Document and report any unresolved problems |
Instruction
|
Published
|
04/21/2025 11:45 AM
|
Routine Maintenance Procedure |
Document Type
|
Published
|
03/02/2020 3:31 PM
|
10 minutes |
Duration
|
Published
|
04/01/2020 11:35 AM
|
Quarterly |
Frequency
|
Published
|
08/02/2020 10:39 PM
|
Note |
Annotation Type
|
Published
|
03/02/2020 3:25 PM
|
Warning |
Annotation Type
|
Published
|
03/02/2020 3:25 PM
|
Technician 1 |
Skill Level
|
Published
|
05/14/2020 2:56 PM
|
Keys to access RPM |
Replacement Parts
|
Published
|
04/27/2023 6:56 PM
|
Reflective safety vest if required |
Replacement Parts
|
Published
|
06/20/2023 4:47 PM
|
Traffic control cones or equivalent if required |
Replacement Parts
|
Published
|
06/20/2023 4:47 PM
|
Magnet |
Replacement Parts
|
Published
|
07/24/2023 9:53 AM
|
LD-260 Disconnect Switch Power On |
படம்
|
Published
|
05/04/2023 3:37 PM
|