7615 |
7615 - Contact system operators and verify RPM is "online" in central alarm station.... |
Remark |
7639 - 7614 - Verify communications are restored; Remark:7615 |
|
✔ |
7616 |
7616 - Close, reopen, and close cabinet doors to clear all tampers from fault queue |
Instruction |
7640 - 7616 - Close, reopen, and close cabinet doors to clear all tampers from fault queue; Remark: |
STEP: 7640 - 7616 - Close, reopen, and close cabinet doors to clear all tampers from fault queue; Remark: RPM +12 VDC Battery Load Test |
✔ |
7617 |
7617 - Open lane |
Instruction |
7641 - 7617 - Open lane; Remark: |
STEP: 7641 - 7617 - Open lane; Remark: RPM +12 VDC Battery Load Test |
✔ |
7620 |
7620 - Warning : 120/220 Vac [alternating current] will be present at the input side of the ac... |
Annotation |
|
|
✔ |
7621 |
7621 - 1401 - Establish Initial Conditions; Remark: |
Procedure Step |
|
|
✔ |
7622 |
7622 - 7592 - Inform system operators; Remark:11335 |
Procedure Step |
|
|
✔ |
7623 |
7623 - 7593 - Brief system operators on expected work and duration before starting work&nbs...; Remark: |
Procedure Step |
|
|
✔ |
7624 |
7624 - 7594 - Close lane and set up barriers to establish a safety watch; Remark:7595 |
Procedure Step |
|
|
✔ |
7625 |
7625 - 7596 - Perform +12 VDC Battery Load Test; Remark: |
Procedure Step |
|
|
✔ |
7626 |
7626 - 7597 - Unlock and open RPM cabinets doors as required to access cabinet interior...; Remark: |
Procedure Step |
|
|
✔ |
7628 |
7628 - Breaker Off |
Remark |
7629 - 7600 - Switch ac power off so green window is visible; Remark:7628 |
STEP: 7629 - 7600 - Switch ac power off so green window is visible; Remark:7628 RPM +12 VDC Battery Load Test |
✔ |
7629 |
7629 - 7600 - Switch ac power off so green window is visible; Remark:7628 |
Procedure Step |
|
|
✔ |
7632 |
7632 - VDC Battery |
Remark |
7633 - 7606 - Measure and record battery voltage; Remark:7632 |
STEP: 7633 - 7606 - Measure and record battery voltage; Remark:7632 RPM +12 VDC Battery Load Test |
✔ |
7633 |
7633 - 7606 - Measure and record battery voltage; Remark:7632 |
Procedure Step |
|
|
✔ |
7634 |
7634 - 7607 - Wait approximately 1 hour; Remark: |
Procedure Step |
|
|
✔ |
7635 |
7635 - 7608 - Re-measure battery voltage; Remark:7609 |
Procedure Step |
|
|
✔ |
7636 |
7636 - 7610 - Switch ac power on so red window is visible; Remark:7611 |
Procedure Step |
|
|
✔ |
7637 |
7637 - 7612 - Close and lock RPM cabinets; Remark: |
Procedure Step |
|
|
✔ |
7640 |
7640 - 7616 - Close, reopen, and close cabinet doors to clear all tampers from fault queue; Remark: |
Procedure Step |
|
|
✔ |
7641 |
7641 - 7617 - Open lane; Remark: |
Procedure Step |
|
|
✔ |
7646 |
7646 - Prepare RPM Specific FCT Datasheet |
Instruction |
7738 - 7646 - Prepare RPM Specific FCT Datasheet; Remark: |
STEP: 7738 - 7646 - Prepare RPM Specific FCT Datasheet; Remark: RPM Functional Compliance Test |
✔ |
7647 |
7647 - Note : Step 1 (1 through 1-4) should be performed before traveling to the RPMs. ... |
Annotation |
7738 - 7646 - Prepare RPM Specific FCT Datasheet; Remark: |
STEP: 7738 - 7646 - Prepare RPM Specific FCT Datasheet; Remark: RPM Functional Compliance Test |
✔ |
7648 |
7648 - Open most recent baselined FCT datasheet on laptop |
Instruction |
7739 - 7648 - Open most recent baselined FCT datasheet on laptop; Remark: |
STEP: 7739 - 7648 - Open most recent baselined FCT datasheet on laptop; Remark: RPM Functional Compliance Test |
✔ |
7649 |
7649 - Save file with unique name (add today's date) and close master copy |
Instruction |
7740 - 7649 - Save file with unique name (add today's date) and close master copy; Remark:7650 |
STEP: 7740 - 7649 - Save file with unique name (add today's date) and close master copy; Remark:7650 RPM Functional Compliance Test |
✔ |
7650 |
7650 - An example of a unique file name is US_PortofEntry_FCT_Lane1_05132016... |
Remark |
7740 - 7649 - Save file with unique name (add today's date) and close master copy; Remark:7650 |
STEP: 7740 - 7649 - Save file with unique name (add today's date) and close master copy; Remark:7650 RPM Functional Compliance Test |
✔ |
7651 |
7651 - Enter date of procedure performance in appropriate cell |
Instruction |
7741 - 7651 - Enter date of procedure performance in appropriate cell; Remark: |
STEP: 7741 - 7651 - Enter date of procedure performance in appropriate cell; Remark: RPM Functional Compliance Test |
✔ |
7652 |
7652 - Note : Date of procedure in FCT datasheet is extremely important for correct radioac... |
Annotation |
7741 - 7651 - Enter date of procedure performance in appropriate cell; Remark: |
STEP: 7741 - 7651 - Enter date of procedure performance in appropriate cell; Remark: RPM Functional Compliance Test |
✔ |
7653 |
7653 - Enter RPM identification information |
Instruction |
7742 - 7653 - Enter RPM identification information; Remark:7654 |
STEP: 7742 - 7653 - Enter RPM identification information; Remark:7654 RPM Functional Compliance Test |
✔ |
7654 |
7654 - Complete the General Information section to specifically identify the RPM (se... |
Remark |
7742 - 7653 - Enter RPM identification information; Remark:7654 |
STEP: 7742 - 7653 - Enter RPM identification information; Remark:7654 RPM Functional Compliance Test |
✔ |
7655 |
7655 - Verify Gamma Radioactive Source is Sufficient for FCT |
Instruction |
7743 - 7655 - Verify Gamma Radioactive Source is Sufficient for FCT; Remark: |
STEP: 7743 - 7655 - Verify Gamma Radioactive Source is Sufficient for FCT; Remark: RPM Functional Compliance Test |
✔ |
7656 |
7656 - Enter Co-57 source identification number |
Instruction |
7744 - 7656 - Enter Co-57 source identification number; Remark:7657 |
STEP: 7744 - 7656 - Enter Co-57 source identification number; Remark:7657 RPM Functional Compliance Test |
✔ |
7657 |
7657 - Source information is commonly listed directly on the label of radioactive so... |
Remark |
7744 - 7656 - Enter Co-57 source identification number; Remark:7657 |
STEP: 7744 - 7656 - Enter Co-57 source identification number; Remark:7657 RPM Functional Compliance Test |
✔ |
7658 |
7658 - Enter Co-57 initial activity in kBq (as listed on source label or source cert... |
Instruction |
7745 - 7658 - Enter Co-57 initial activity in kBq (as listed on source label or source cert...; Remark:7659 |
STEP: 7745 - 7658 - Enter Co-57 initial activity in kBq (as listed on source label or source cert...; Remark:7659 RPM Functional Compliance Test |
✔ |
7659 |
7659 - Source Activity Level |
Remark |
7745 - 7658 - Enter Co-57 initial activity in kBq (as listed on source label or source cert...; Remark:7659 |
STEP: 7745 - 7658 - Enter Co-57 initial activity in kBq (as listed on source label or source cert...; Remark:7659 RPM Functional Compliance Test |
✔ |
7660 |
7660 - Enter Co-57 source calibration date |
Instruction |
7746 - 7660 - Enter Co-57 source calibration date; Remark:7661 |
STEP: 7746 - 7660 - Enter Co-57 source calibration date; Remark:7661 RPM Functional Compliance Test |
✔ |
7661 |
7661 - Source Calibration Date |
Remark |
7746 - 7660 - Enter Co-57 source calibration date; Remark:7661 |
STEP: 7746 - 7660 - Enter Co-57 source calibration date; Remark:7661 RPM Functional Compliance Test |
✔ |
7662 |
7662 - Verify Co-57 calculated current activity is within specified limits |
Instruction |
7747 - 7662 - Verify Co-57 calculated current activity is within specified limits; Remark:7664 |
STEP: 7747 - 7662 - Verify Co-57 calculated current activity is within specified limits; Remark:7664 RPM Functional Compliance Test |
✔ |
7663 |
7663 - Standard : Current Co-57 source activity must be between 19 and 400 kBq to perform this ... |
Annotation |
7747 - 7662 - Verify Co-57 calculated current activity is within specified limits; Remark:7664 |
STEP: 7747 - 7662 - Verify Co-57 calculated current activity is within specified limits; Remark:7664 RPM Functional Compliance Test |
✔ |
7664 |
7664 - Source Current Activity Level |
Remark |
7747 - 7662 - Verify Co-57 calculated current activity is within specified limits; Remark:7664 |
STEP: 7747 - 7662 - Verify Co-57 calculated current activity is within specified limits; Remark:7664 RPM Functional Compliance Test |
✔ |
7665 |
7665 - Verify Neutron Radioactive Source is Sufficient for FCT ... |
Instruction |
7748 - 7665 - Verify Neutron Radioactive Source is Sufficient for FCT ...; Remark: |
STEP: 7748 - 7665 - Verify Neutron Radioactive Source is Sufficient for FCT ...; Remark: RPM Functional Compliance Test |
✔ |
7666 |
7666 - Enter Cf-252 source identification number |
Instruction |
7749 - 7666 - Enter Cf-252 source identification number; Remark:7667 |
STEP: 7749 - 7666 - Enter Cf-252 source identification number; Remark:7667 RPM Functional Compliance Test |
✔ |
7667 |
7667 - Source information is commonly listed directly on the label of the radioactiv... |
Remark |
7749 - 7666 - Enter Cf-252 source identification number; Remark:7667 |
STEP: 7749 - 7666 - Enter Cf-252 source identification number; Remark:7667 RPM Functional Compliance Test |
✔ |
7668 |
7668 - Enter Cf-252 source activity in kBq (as listed on source label or source cert... |
Instruction |
7750 - 7668 - Enter Cf-252 source activity in kBq (as listed on source label or source cert...; Remark:7669 |
STEP: 7750 - 7668 - Enter Cf-252 source activity in kBq (as listed on source label or source cert...; Remark:7669 RPM Functional Compliance Test |
✔ |
7669 |
7669 - |
Remark |
7750 - 7668 - Enter Cf-252 source activity in kBq (as listed on source label or source cert...; Remark:7669 |
STEP: 7750 - 7668 - Enter Cf-252 source activity in kBq (as listed on source label or source cert...; Remark:7669 RPM Functional Compliance Test |
✔ |
7670 |
7670 - Enter Cf-252 source calibration date |
Instruction |
7751 - 7670 - Enter Cf-252 source calibration date; Remark:7671 |
STEP: 7751 - 7670 - Enter Cf-252 source calibration date; Remark:7671 RPM Functional Compliance Test |
✔ |
7671 |
7671 - Certificate of Calibration Neutron Date |
Remark |
7751 - 7670 - Enter Cf-252 source calibration date; Remark:7671 |
STEP: 7751 - 7670 - Enter Cf-252 source calibration date; Remark:7671 RPM Functional Compliance Test |
✔ |
7672 |
7672 - Standard : Current Cf-252 source activity must be between 37 and 185 kBq to perform this... |
Annotation |
7752 - 7673 - Verify Cf-252 calculated current activity is within specified limits; Remark:7674 |
STEP: 7752 - 7673 - Verify Cf-252 calculated current activity is within specified limits; Remark:7674 RPM Functional Compliance Test |
✔ |
7673 |
7673 - Verify Cf-252 calculated current activity is within specified limits |
Instruction |
7752 - 7673 - Verify Cf-252 calculated current activity is within specified limits; Remark:7674 |
STEP: 7752 - 7673 - Verify Cf-252 calculated current activity is within specified limits; Remark:7674 RPM Functional Compliance Test |
✔ |
7674 |
7674 - Current Cf-252 source activity must be between 2,000 and 20,000 n/s to perfor... |
Remark |
7752 - 7673 - Verify Cf-252 calculated current activity is within specified limits; Remark:7674 |
STEP: 7752 - 7673 - Verify Cf-252 calculated current activity is within specified limits; Remark:7674 RPM Functional Compliance Test |
✔ |
7676 |
7676 - Brief system operators on expected work, duration, anticipated alarms, and fa... |
Instruction |
7753 - 7676 - Brief system operators on expected work, duration, anticipated alarms, and fa...; Remark:7677 7824 - 7676 - Brief system operators on expected work, duration, anticipated alarms, and fa...; Remark:7677 8221 - 7676 - Brief system operators on expected work, duration, anticipated alarms, and fa...; Remark: 9244 - 7676 - Brief system operators on expected work, duration, anticipated alarms, and fa...; Remark:7677 9285 - 7676 - Brief system operators on expected work, duration, anticipated alarms, and fa...; Remark: 9335 - 7676 - Brief system operators on expected work, duration, anticipated alarms, and fa...; Remark: 9414 - 7676 - Brief system operators on expected work, duration, anticipated alarms, and fa...; Remark: 10334 - 7676 - Brief system operators on expected work, duration, anticipated alarms, and fa...; Remark: |
STEP: 7753 - 7676 - Brief system operators on expected work, duration, anticipated alarms, and fa...; Remark:7677 RPM Functional Compliance Test
STEP: 8221 - 7676 - Brief system operators on expected work, duration, anticipated alarms, and fa...; Remark: RPM Rabbit Board Replacement RPM Sonalert Module Replacement RPM Neutron Detector Helium-3 (He3) Tube Replacement RPM RS232 to RS485 Converter Replacement RPM Alarm Strobe Light Assembly Replacement RPM ELK Siren Replacement RPM ELK Siren Driver Replacement RPM ELK Siren Driver Replacement RPM AC Line Filter Replacement RPM HHV-448/458 High Voltage Board Replacement
STEP: 10334 - 7676 - Brief system operators on expected work, duration, anticipated alarms, and fa...; Remark: RPM AM-270 Remote Alarm Panel Replacement |
✔ |
7677 |
7677 - Operators should expect numerous fault indications and alarms during procedur... |
Remark |
7753 - 7676 - Brief system operators on expected work, duration, anticipated alarms, and fa...; Remark:7677 7824 - 7676 - Brief system operators on expected work, duration, anticipated alarms, and fa...; Remark:7677 9244 - 7676 - Brief system operators on expected work, duration, anticipated alarms, and fa...; Remark:7677 9500 - 9428 - Brief system operators on expected work, duration, anticipated alarms, and fa...; Remark:7677 |
STEP: 7753 - 7676 - Brief system operators on expected work, duration, anticipated alarms, and fa...; Remark:7677 RPM Functional Compliance Test |
✔ |
7678 |
7678 - Warning : Traffic should temporarily be rerouted or halted during conduction of this pr... |
Annotation |
7754 - 7594 - Close lane and set up barriers to establish a safety watch; Remark:7595 7825 - 7594 - Close lane and set up barriers to establish a safety watch; Remark:7595 7847 - 7594 - Close lane and set up barriers to establish a safety watch; Remark:7846 7984 - 7980 - Close lane and set up barriers or establish a safety watch; Remark:7595 10267 - 7967 - Close lane and set up barriers or establish a safety watch; Remark:7571 10335 - 7967 - Close lane and set up barriers or establish a safety watch; Remark:7595 |
STEP: 7754 - 7594 - Close lane and set up barriers to establish a safety watch; Remark:7595 RPM Functional Compliance Test
STEP: 7984 - 7980 - Close lane and set up barriers or establish a safety watch; Remark:7595 RPM Operational Test
STEP: 10267 - 7967 - Close lane and set up barriers or establish a safety watch; Remark:7571 RPM ELK Siren Replacement |
✔ |
7679 |
7679 - Disconnect Ethernet |
Instruction |
7755 - 7679 - Disconnect Ethernet; Remark:11336 8205 - 7679 - Disconnect Ethernet; Remark:8204 9506 - 7679 - Disconnect Ethernet; Remark:9541 |
STEP: 7755 - 7679 - Disconnect Ethernet; Remark:11336 RPM LD-260 Load Disconnect Replacement RPM Ethernet-to-Fiber Media Converter Replacement RPM IXIO-DT1 Occupancy Sensor Replacement RPM Functional Compliance Test RPM SCA-774 Single Channel Analyzer Board Replacement RPM SCA-775 Module Replacement RPM LD-260 Load Disconnect Fuse Replacement RPM SC-771 Controller Board Replacement RPM SC-770 Controller Module Replacement RPM Banner IR Occupancy Sensor Replacement RPM SPY-2 to IXIO-DT1 Occupancy Sensor Conversion RPM Nano Controller Replacement RPM Neutron Signal Pick-Off Box (PMFX) Replacement RPM VD-580 Replacement RPM SC-770 Rabbit Board Firmware Update
STEP: 8205 - 7679 - Disconnect Ethernet; Remark:8204 RPM Rabbit Board Replacement |
✔ |
7680 |
7680 - Caution : Make sure to press release button on back of Ethernet cable before removing. |
Annotation |
7755 - 7679 - Disconnect Ethernet; Remark:11336 8205 - 7679 - Disconnect Ethernet; Remark:8204 9506 - 7679 - Disconnect Ethernet; Remark:9541 |
STEP: 7755 - 7679 - Disconnect Ethernet; Remark:11336 RPM LD-260 Load Disconnect Replacement RPM Ethernet-to-Fiber Media Converter Replacement RPM IXIO-DT1 Occupancy Sensor Replacement RPM Functional Compliance Test RPM SCA-774 Single Channel Analyzer Board Replacement RPM SCA-775 Module Replacement RPM LD-260 Load Disconnect Fuse Replacement RPM SC-771 Controller Board Replacement RPM SC-770 Controller Module Replacement RPM Banner IR Occupancy Sensor Replacement RPM SPY-2 to IXIO-DT1 Occupancy Sensor Conversion RPM Nano Controller Replacement RPM Neutron Signal Pick-Off Box (PMFX) Replacement RPM VD-580 Replacement RPM SC-770 Rabbit Board Firmware Update
STEP: 8205 - 7679 - Disconnect Ethernet; Remark:8204 RPM Rabbit Board Replacement |
✔ |
7681 |
7681 - Disable occupancy sensor |
Instruction |
7756 - 7681 - Disable occupancy sensor; Remark:7682 |
STEP: 7756 - 7681 - Disable occupancy sensor; Remark:7682 RPM Functional Compliance Test |
✔ |
7682 |
7682 - For vehicle monitor, disconnect both break-beam sensor receivers (usually*) l... |
Remark |
7756 - 7681 - Disable occupancy sensor; Remark:7682 |
STEP: 7756 - 7681 - Disable occupancy sensor; Remark:7682 RPM Functional Compliance Test |
✔ |
7683 |
7683 - Record SC-770 parameter values |
Instruction |
7760 - 7683 - Record SC-770 parameter values; Remark:7684 8244 - 7683 - Record SC-770 parameter values; Remark:8243 |
STEP: 7760 - 7683 - Record SC-770 parameter values; Remark:7684 RPM Functional Compliance Test
STEP: 8244 - 7683 - Record SC-770 parameter values; Remark:8243 RPM SC-771 Controller Board Replacement |
✔ |
7684 |
7684 - Enter Program Mode by pressing "0." Enter the password 1234... |
Remark |
7760 - 7683 - Record SC-770 parameter values; Remark:7684 8455 - 8451 - Verify SC-770 firmware version; Remark:7684 |
STEP: 7760 - 7683 - Record SC-770 parameter values; Remark:7684 RPM Functional Compliance Test |
✔ |
7685 |
7685 - Caution : Each SC-770 parameter must match the values obtained from the LANL configurat... |
Annotation |
7760 - 7683 - Record SC-770 parameter values; Remark:7684 |
STEP: 7760 - 7683 - Record SC-770 parameter values; Remark:7684 RPM Functional Compliance Test |
✔ |
7686 |
7686 - Manually enter variable values |
Instruction |
7761 - 7686 - Manually enter variable values; Remark:7687 |
STEP: 7761 - 7686 - Manually enter variable values; Remark:7687 RPM Functional Compliance Test |
✔ |
7687 |
7687 - Variable values include parameters such as N*Sigma and Alpha value. |
Remark |
7761 - 7686 - Manually enter variable values; Remark:7687 |
STEP: 7761 - 7686 - Manually enter variable values; Remark:7687 RPM Functional Compliance Test |
✔ |
7688 |
7688 - Click the check box to confirm fixed values |
Instruction |
7762 - 7688 - Click the check box to confirm fixed values; Remark: |
STEP: 7762 - 7688 - Click the check box to confirm fixed values; Remark: RPM Functional Compliance Test |
✔ |
7689 |
7689 - Return to SC-770 main menu |
Instruction |
7763 - 7689 - Return to SC-770 main menu; Remark:7690 |
STEP: 7763 - 7689 - Return to SC-770 main menu; Remark:7690 RPM Functional Compliance Test |
✔ |
7690 |
7690 - Press "#" button until the SC-770 displays the main menu. |
Remark |
7763 - 7689 - Return to SC-770 main menu; Remark:7690 |
STEP: 7763 - 7689 - Return to SC-770 main menu; Remark:7690 RPM Functional Compliance Test |
✔ |
7691 |
7691 - Perform Gamma Detector Efficiency Measurements |
Instruction |
7764 - 7691 - Perform Gamma Detector Efficiency Measurements; Remark: |
STEP: 7764 - 7691 - Perform Gamma Detector Efficiency Measurements; Remark: RPM Functional Compliance Test |
✔ |
7692 |
7692 - Caution : Keep gamma detectors protected from direct sunlight. |
Annotation |
7765 - 7694 - Navigate SC-770 to SHOW COUNTS for gamma detectors; Remark:7695 |
STEP: 7765 - 7694 - Navigate SC-770 to SHOW COUNTS for gamma detectors; Remark:7695 RPM Functional Compliance Test |
✔ |
7693 |
7693 - Note : Verify there are no radiation sources sources within 20 meters of the RPM whi... |
Annotation |
7765 - 7694 - Navigate SC-770 to SHOW COUNTS for gamma detectors; Remark:7695 |
STEP: 7765 - 7694 - Navigate SC-770 to SHOW COUNTS for gamma detectors; Remark:7695 RPM Functional Compliance Test |
✔ |
7694 |
7694 - Navigate SC-770 to SHOW COUNTS for gamma detectors |
Instruction |
7765 - 7694 - Navigate SC-770 to SHOW COUNTS for gamma detectors; Remark:7695 |
STEP: 7765 - 7694 - Navigate SC-770 to SHOW COUNTS for gamma detectors; Remark:7695 RPM Functional Compliance Test |
✔ |
7695 |
7695 - From SC-770 main programming menu, press GAMMA |
Remark |
7765 - 7694 - Navigate SC-770 to SHOW COUNTS for gamma detectors; Remark:7695 |
STEP: 7765 - 7694 - Navigate SC-770 to SHOW COUNTS for gamma detectors; Remark:7695 RPM Functional Compliance Test |
✔ |
7696 |
7696 - Record measured gamma background count rate for each gamma detector |
Instruction |
7766 - 7696 - Record measured gamma background count rate for each gamma detector; Remark:7697 |
STEP: 7766 - 7696 - Record measured gamma background count rate for each gamma detector; Remark:7697 RPM Functional Compliance Test |
✔ |
7697 |
7697 - Stand clear of all gamma detectors, watch displayed count rate for each chann... |
Remark |
7766 - 7696 - Record measured gamma background count rate for each gamma detector; Remark:7697 |
STEP: 7766 - 7696 - Record measured gamma background count rate for each gamma detector; Remark:7697 RPM Functional Compliance Test |
✔ |
7698 |
7698 - Standard : Due to low energy of Co-57 gammas, the count rate on either side of the sourc... |
Annotation |
7767 - 7700 - Place label side of Co-57 gamma source against yellow dot at center of detect...; Remark:7701 |
STEP: 7767 - 7700 - Place label side of Co-57 gamma source against yellow dot at center of detect...; Remark:7701 RPM Functional Compliance Test |
✔ |
7699 |
7699 - Note : Verify distance between source and detector is minimized to warrant accurate ... |
Annotation |
7767 - 7700 - Place label side of Co-57 gamma source against yellow dot at center of detect...; Remark:7701 |
STEP: 7767 - 7700 - Place label side of Co-57 gamma source against yellow dot at center of detect...; Remark:7701 RPM Functional Compliance Test |
✔ |
7700 |
7700 - Place label side of Co-57 gamma source against yellow dot at center of detect... |
Instruction |
7767 - 7700 - Place label side of Co-57 gamma source against yellow dot at center of detect...; Remark:7701 |
STEP: 7767 - 7700 - Place label side of Co-57 gamma source against yellow dot at center of detect...; Remark:7701 RPM Functional Compliance Test |
✔ |
7701 |
7701 - The source must be held firmly against the detector with a low-density tool s... |
Remark |
7767 - 7700 - Place label side of Co-57 gamma source against yellow dot at center of detect...; Remark:7701 |
STEP: 7767 - 7700 - Place label side of Co-57 gamma source against yellow dot at center of detect...; Remark:7701 RPM Functional Compliance Test |
✔ |
7702 |
7702 - Record gamma count rate in appropriate "Source Count Rate (Co-57)" cell |
Instruction |
7768 - 7702 - Record gamma count rate in appropriate "Source Count Rate (Co-57)" cell; Remark:7704 |
STEP: 7768 - 7702 - Record gamma count rate in appropriate "Source Count Rate (Co-57)" cell; Remark:7704 RPM Functional Compliance Test |
✔ |
7703 |
7703 - Note : Verify that there are no additional radiation sources within 20 meters of the... |
Annotation |
7768 - 7702 - Record gamma count rate in appropriate "Source Count Rate (Co-57)" cell; Remark:7704 |
STEP: 7768 - 7702 - Record gamma count rate in appropriate "Source Count Rate (Co-57)" cell; Remark:7704 RPM Functional Compliance Test |
✔ |
7704 |
7704 - Stand clear of all gamma detectors, watch displayed count rate for each chann... |
Remark |
7768 - 7702 - Record gamma count rate in appropriate "Source Count Rate (Co-57)" cell; Remark:7704 |
STEP: 7768 - 7702 - Record gamma count rate in appropriate "Source Count Rate (Co-57)" cell; Remark:7704 RPM Functional Compliance Test |
✔ |
7705 |
7705 - Repeat for each gamma detector in RPM |
Instruction |
7769 - 7705 - Repeat for each gamma detector in RPM; Remark: |
STEP: 7769 - 7705 - Repeat for each gamma detector in RPM; Remark: RPM Functional Compliance Test |
✔ |
7706 |
7706 - Standard : Gamma detector efficiency should be greater than 20% |
Annotation |
7770 - 7707 - Verify gamma detector efficiency; Remark:7708 |
STEP: 7770 - 7707 - Verify gamma detector efficiency; Remark:7708 RPM Functional Compliance Test |
✔ |
7707 |
7707 - Verify gamma detector efficiency |
Instruction |
7770 - 7707 - Verify gamma detector efficiency; Remark:7708 |
STEP: 7770 - 7707 - Verify gamma detector efficiency; Remark:7708 RPM Functional Compliance Test |
✔ |
7708 |
7708 - Gamma Detector Efficiency |
Remark |
7770 - 7707 - Verify gamma detector efficiency; Remark:7708 |
STEP: 7770 - 7707 - Verify gamma detector efficiency; Remark:7708 RPM Functional Compliance Test |
✔ |
7709 |
7709 - Go to SC-770 main menu |
Instruction |
7771 - 7709 - Go to SC-770 main menu; Remark:7710 |
STEP: 7771 - 7709 - Go to SC-770 main menu; Remark:7710 RPM Functional Compliance Test |
✔ |
7710 |
7710 - Press "#" button until the SC-770 displays the main menu. |
Remark |
7771 - 7709 - Go to SC-770 main menu; Remark:7710 |
STEP: 7771 - 7709 - Go to SC-770 main menu; Remark:7710 RPM Functional Compliance Test |
✔ |
7711 |
7711 - Perform Neutron Detector Efficiency Measurements |
Instruction |
7772 - 7711 - Perform Neutron Detector Efficiency Measurements; Remark: |
STEP: 7772 - 7711 - Perform Neutron Detector Efficiency Measurements; Remark: RPM Functional Compliance Test |
✔ |
7712 |
7712 - Enter "fixed" neutron background count rate for each neutron detector |
Instruction |
7773 - 7712 - Enter "fixed" neutron background count rate for each neutron detector; Remark:7713 |
STEP: 7773 - 7712 - Enter "fixed" neutron background count rate for each neutron detector; Remark:7713 RPM Functional Compliance Test |
✔ |
7713 |
7713 - Record 1 counts per second (cps) for each neutron tube installed on each chan... |
Remark |
7773 - 7712 - Enter "fixed" neutron background count rate for each neutron detector; Remark:7713 |
STEP: 7773 - 7712 - Enter "fixed" neutron background count rate for each neutron detector; Remark:7713 RPM Functional Compliance Test |
✔ |
7714 |
7714 - Navigate SC-770 to SHOW COUNTS for neutron detectors |
Instruction |
7774 - 7714 - Navigate SC-770 to SHOW COUNTS for neutron detectors; Remark:7715 |
STEP: 7774 - 7714 - Navigate SC-770 to SHOW COUNTS for neutron detectors; Remark:7715 RPM Functional Compliance Test |
✔ |
7715 |
7715 - From SC-770 main programming menu, press NEUTRON ... |
Remark |
7774 - 7714 - Navigate SC-770 to SHOW COUNTS for neutron detectors; Remark:7715 |
STEP: 7774 - 7714 - Navigate SC-770 to SHOW COUNTS for neutron detectors; Remark:7715 RPM Functional Compliance Test |
✔ |
7716 |
7716 - Warning : Do not hold the neutron source on the detector face with your hand or stand n... |
Annotation |
7775 - 7718 - Place Cf-252 neutron source against yellow dot on center of detector; Remark:7719 |
STEP: 7775 - 7718 - Place Cf-252 neutron source against yellow dot on center of detector; Remark:7719 RPM Functional Compliance Test |
✔ |
7717 |
7717 - Note : During the neutron detector efficiency tests, verify no one is near t... |
Annotation |
7775 - 7718 - Place Cf-252 neutron source against yellow dot on center of detector; Remark:7719 |
STEP: 7775 - 7718 - Place Cf-252 neutron source against yellow dot on center of detector; Remark:7719 RPM Functional Compliance Test |
✔ |
7718 |
7718 - Place Cf-252 neutron source against yellow dot on center of detector |
Instruction |
7775 - 7718 - Place Cf-252 neutron source against yellow dot on center of detector; Remark:7719 |
STEP: 7775 - 7718 - Place Cf-252 neutron source against yellow dot on center of detector; Remark:7719 RPM Functional Compliance Test |
✔ |
7719 |
7719 - It is acceptable to use adhesive tape for this step |
Remark |
7775 - 7718 - Place Cf-252 neutron source against yellow dot on center of detector; Remark:7719 |
STEP: 7775 - 7718 - Place Cf-252 neutron source against yellow dot on center of detector; Remark:7719 RPM Functional Compliance Test |
✔ |
7720 |
7720 - Record neutron count rate in appropriate "Source Count Rate (Cf-252)" cell |
Instruction |
7776 - 7720 - Record neutron count rate in appropriate "Source Count Rate (Cf-252)" cell; Remark:7722 |
STEP: 7776 - 7720 - Record neutron count rate in appropriate "Source Count Rate (Cf-252)" cell; Remark:7722 RPM Functional Compliance Test |
✔ |
7721 |
7721 - Note : Ensure that threre are no additional radiation sources within 20 meters of th... |
Annotation |
7776 - 7720 - Record neutron count rate in appropriate "Source Count Rate (Cf-252)" cell; Remark:7722 |
STEP: 7776 - 7720 - Record neutron count rate in appropriate "Source Count Rate (Cf-252)" cell; Remark:7722 RPM Functional Compliance Test |
✔ |
7722 |
7722 - Stand clear of all neutron detectors, watch displayed count rate for each cha... |
Remark |
7776 - 7720 - Record neutron count rate in appropriate "Source Count Rate (Cf-252)" cell; Remark:7722 |
STEP: 7776 - 7720 - Record neutron count rate in appropriate "Source Count Rate (Cf-252)" cell; Remark:7722 RPM Functional Compliance Test |
✔ |
7723 |
7723 - Repeat for all neutron detectors in RPM |
Instruction |
7777 - 7723 - Repeat for all neutron detectors in RPM; Remark: |
STEP: 7777 - 7723 - Repeat for all neutron detectors in RPM; Remark: RPM Functional Compliance Test |
✔ |
7724 |
7724 - Verify neutron detector efficiency |
Instruction |
7778 - 7724 - Verify neutron detector efficiency; Remark:7726 |
STEP: 7778 - 7724 - Verify neutron detector efficiency; Remark:7726 RPM Functional Compliance Test |
✔ |
7725 |
7725 - Standard : Neutron detector efficiency should be greater than 5% (VM with 2 helium tubes... |
Annotation |
7778 - 7724 - Verify neutron detector efficiency; Remark:7726 |
STEP: 7778 - 7724 - Verify neutron detector efficiency; Remark:7726 RPM Functional Compliance Test |
✔ |
7726 |
7726 - Neutron Source Efficiency |
Remark |
7778 - 7724 - Verify neutron detector efficiency; Remark:7726 |
STEP: 7778 - 7724 - Verify neutron detector efficiency; Remark:7726 RPM Functional Compliance Test |
✔ |