2300 |
2300 - IO RadSeeker Stabilizing Status |
Remark |
2342 - 2337 - WAIT for instrument to complete stabilization; Remark:2300 |
|
✔ |
2301 |
2301 - Open the battery cover to view the charge level indicator. |
Remark |
2348 - 2295 - Verify sufficient battery charge; Remark:2301 4713 - 2295 - Verify sufficient battery charge; Remark:2301 |
STEP: 2348 - 2295 - Verify sufficient battery charge; Remark:2301 RadSeeker Operation RadSeeker CS/CL Wi-Fi Status Change
STEP: 4713 - 2295 - Verify sufficient battery charge; Remark:2301 RadSeeker Routine Assessment |
✔ |
2302 |
2302 - Replace battery pack or charge instrument if fewer than two (2) bars are visi... |
Remark |
2348 - 2295 - Verify sufficient battery charge; Remark:2301 |
STEP: 2348 - 2295 - Verify sufficient battery charge; Remark:2301 RadSeeker Operation RadSeeker CS/CL Wi-Fi Status Change |
✔ |
2303 |
2303 - Press and hold ENTER button until display powers on (3 to 5 ... |
Remark |
2460 - 220 - Power on instrument; Remark:2303 3720 - 220 - Power on instrument; Remark:2303 5372 - 220 - Power on instrument; Remark:2303 |
STEP: 2460 - 220 - Power on instrument; Remark:2303 RadSeeker Operation RadSeeker Operational Test
STEP: 3720 - 220 - Power on instrument; Remark:2303 RadSeeker Upload and Attach with RAVEN RadSeeker Upload and Attach with Schneider |
✔ |
2304 |
2304 - Wait for instrument to display the message “Power On Self-Test Passed”. I... |
Remark |
2461 - 2349 - Verify successful completion of self-test; Remark:2304 |
|
✔ |
2305 |
2305 - Wait approximately 30 seconds until the instrument completes system stabiliza... |
Remark |
|
|
✔ |
2306 |
2306 - The instrument will automatically enter Detect mode after sy... |
Remark |
2462 - 612 - Wait for instrument to complete start-up sequence; Remark:2306 4746 - 4728 - Verify instrument successfully completes startup; Remark:2306 4983 - 612 - Wait for instrument to complete start-up sequence; Remark:2306 |
STEP: 2462 - 612 - Wait for instrument to complete start-up sequence; Remark:2306 RadSeeker Operation RadSeeker Operational Test RadSeeker CS/CL Wi-Fi Status Change
STEP: 4746 - 4728 - Verify instrument successfully completes startup; Remark:2306 RadSeeker Routine Assessment
STEP: 4983 - 612 - Wait for instrument to complete start-up sequence; Remark:2306 RadSeeker Internal Battery Replacement |
✔ |
2307 |
2307 - It is recommended to perform an operational test daily before use. See DET-HH... |
Remark |
2463 - 319 - Perform operational test; Remark:2307 |
STEP: 2463 - 319 - Perform operational test; Remark:2307 RadSeeker Operation |
✔ |
2308 |
2308 - Press the UP arrow to activate the ADI. |
Remark |
2465 - 2352 - Verify Audible Dose Rate Indicator (ADI) is on; Remark:2308 |
STEP: 2465 - 2352 - Verify Audible Dose Rate Indicator (ADI) is on; Remark:2308 RadSeeker Operation |
✔ |
2309 |
2309 - IO RadSeeker Raster Scan Box |
Remark |
2466 - 2215 - Survey slowly over entire item; Remark:2315 3491 - 617 - SURVEY SLOWLY over entire item (20 centimeters/second); Remark:2309 |
STEP: 2466 - 2215 - Survey slowly over entire item; Remark:2315 RadSeeker Operation
STEP: 3491 - 617 - SURVEY SLOWLY over entire item (20 centimeters/second); Remark:2309 Smiths Detection RadSeeker CS |
✔ |
2310 |
2310 - Gamma Dose Rate (µSv/hr) values will increase. Gamma coun... |
Remark |
2467 - 2353 - Observe display and listen for audible alarms or vibration; Remark:2310 3515 - 3509 - Verify DETECT mode responds correctly; Remark:3510 |
STEP: 2467 - 2353 - Observe display and listen for audible alarms or vibration; Remark:2310 RadSeeker Operation
STEP: 3515 - 3509 - Verify DETECT mode responds correctly; Remark:3510 RadSeeker Operational Test |
✔ |
2311 |
2311 - IO RadSeeker Vibrate Sound Icons |
Remark |
2467 - 2353 - Observe display and listen for audible alarms or vibration; Remark:2310 |
STEP: 2467 - 2353 - Observe display and listen for audible alarms or vibration; Remark:2310 RadSeeker Operation |
✔ |
2312 |
2312 - Press ENTER to acknowledge any alarms. |
Remark |
2468 - 2357 - Acknowledge alarms; Remark:2312 |
STEP: 2468 - 2357 - Acknowledge alarms; Remark:2312 RadSeeker Operation |
✔ |
2314 |
2314 - Scan surfaces in a methodical fashion to ensure thorough inspection. Random s... |
Remark |
|
|
✔ |
2315 |
2315 - Move instrument approximately 20 cm per second. Thoroughly survey all accessi... |
Remark |
2466 - 2215 - Survey slowly over entire item; Remark:2315 4300 - 366 - Pomalu přezkoumejte celý předmět; Remark:2315 10700 - 366 - Survey slowly over entire item; Remark:2315 |
STEP: 2466 - 2215 - Survey slowly over entire item; Remark:2315 RadSeeker Operation
STEP: 4300 - 366 - Pomalu přezkoumejte celý předmět; Remark:2315 Handheld Radiation Monitor Operation
STEP: 10700 - 366 - Survey slowly over entire item; Remark:2315 radEAGLET Operation |
✔ |
2316 |
2316 - IO RadSeeker Shutting Down |
Remark |
2487 - 2478 - POWER OFF instrument - PRESS and HO...; Remark:2316 2497 - 313 - Power off instrument; Remark:2330 |
STEP: 2487 - 2478 - POWER OFF instrument - PRESS and HO...; Remark:2316 Smiths Detection RadSeeker CS
STEP: 2497 - 313 - Power off instrument; Remark:2330 RadSeeker Operation RadSeeker Internal Battery Replacement RadSeeker Operation RadSeeker Stabilization Module Replacement RadSeeker Operation RadSeeker CS/CL Wi-Fi Status Change |
✔ |
2317 |
2317 - Press ENTER under Detect. |
Remark |
2495 - 2359 - Return to Detect mode; Remark:2317 |
STEP: 2495 - 2359 - Return to Detect mode; Remark:2317 RadSeeker Operation |
✔ |
2318 |
2318 - IO RadSeeker Add Time Button |
Remark |
2484 - 2473 - If additional time is needed,; Remark:2318 2494 - 2358 - Add identification time (if needed); Remark:2327 |
STEP: 2494 - 2358 - Add identification time (if needed); Remark:2327 RadSeeker Operation |
✔ |
2319 |
2319 - IO RadSeeker Identify Isotope Co60 |
Remark |
2483 - 628 - OBSERVE identification results; Remark:2319 2493 - 2221 - Observe identification results; Remark:2319 3522 - 1442 - Verify identification results are correct; Remark:3497 |
STEP: 2483 - 628 - OBSERVE identification results; Remark:2319 Smiths Detection RadSeeker CS
STEP: 2493 - 2221 - Observe identification results; Remark:2319 RadSeeker Operation
STEP: 3522 - 1442 - Verify identification results are correct; Remark:3497 RadSeeker Operational Test |
✔ |
2320 |
2320 - IO RadSeeker Alarm Acknowledge Threat |
Remark |
2482 - 2472 - PRESS ENTER to acknowledge alarms; Remark:2320 2492 - 2357 - Acknowledge alarms; Remark:2326 |
STEP: 2482 - 2472 - PRESS ENTER to acknowledge alarms; Remark:2320 Smiths Detection RadSeeker CS
STEP: 2492 - 2357 - Acknowledge alarms; Remark:2326 RadSeeker Operation RadSeeker Operational Test |
✔ |
2321 |
2321 - IO RadSeeker Collecting Spectrum Wait |
Remark |
2481 - 2220 - Wait for measurement to complete; Remark:2321 2491 - 2220 - Wait for measurement to complete; Remark:2321 |
STEP: 2481 - 2220 - Wait for measurement to complete; Remark:2321 Smiths Detection RadSeeker CS
STEP: 2491 - 2220 - Wait for measurement to complete; Remark:2321 RadSeeker Operation RadSeeker Operational Test |
✔ |
2322 |
2322 - Press ENTER under Start ID. |
Remark |
2490 - 859 - Start identification measurement; Remark:2322 |
STEP: 2490 - 859 - Start identification measurement; Remark:2322 RadSeeker Operation |
✔ |
2323 |
2323 - IO RadSeeker Trefoil Box Identify |
Remark |
2459 - 625 - PLACE instrument close to measurement location; Remark:2323 2489 - 2218 - Place instrument close to measurement location; Remark:2325 |
STEP: 2459 - 625 - PLACE instrument close to measurement location; Remark:2323 Smiths Detection RadSeeker CS
STEP: 2489 - 2218 - Place instrument close to measurement location; Remark:2325 RadSeeker Operation |
✔ |
2324 |
2324 - IO RadSeeker ADI Bar |
Remark |
2343 - 2338 - VERIFY Audible Dose Rate Indicator (ADI) is on (green backli...; Remark:2324 3513 - 2352 - Verify Audible Dose Rate Indicator (ADI) is on; Remark:3502 |
STEP: 2343 - 2338 - VERIFY Audible Dose Rate Indicator (ADI) is on (green backli...; Remark:2324 Smiths Detection RadSeeker CS
STEP: 3513 - 2352 - Verify Audible Dose Rate Indicator (ADI) is on; Remark:3502 RadSeeker Operational Test |
✔ |
2325 |
2325 - The instrument should be as close as possible without making contact. |
Remark |
2489 - 2218 - Place instrument close to measurement location; Remark:2325 10674 - 2218 - Place instrument close to measurement location; Remark:2325 |
STEP: 2489 - 2218 - Place instrument close to measurement location; Remark:2325 RadSeeker Operation
STEP: 10674 - 2218 - Place instrument close to measurement location; Remark:2325 radEAGLET Operation |
✔ |
2326 |
2326 - Press ENTER to acknowledge innocent or threat alarms. |
Remark |
2492 - 2357 - Acknowledge alarms; Remark:2326 |
STEP: 2492 - 2357 - Acknowledge alarms; Remark:2326 RadSeeker Operation RadSeeker Operational Test |
✔ |
2327 |
2327 - Press the UP arrow to add time. |
Remark |
2494 - 2358 - Add identification time (if needed); Remark:2327 |
STEP: 2494 - 2358 - Add identification time (if needed); Remark:2327 RadSeeker Operation |
✔ |
2328 |
2328 - Press DOWN to choose additional time needed. Press E... |
Remark |
2494 - 2358 - Add identification time (if needed); Remark:2327 |
STEP: 2494 - 2358 - Add identification time (if needed); Remark:2327 RadSeeker Operation |
✔ |
2329 |
2329 - Follow accepted procedures for site to record results. |
Remark |
2496 - 2222 - Record identification results; Remark:2329 |
|
✔ |
2330 |
2330 - Press ENTER until the screen displays Shutting down |
Remark |
2497 - 313 - Power off instrument; Remark:2330 |
STEP: 2497 - 313 - Power off instrument; Remark:2330 RadSeeker Operation RadSeeker Internal Battery Replacement RadSeeker Operation RadSeeker Stabilization Module Replacement RadSeeker Operation RadSeeker CS/CL Wi-Fi Status Change |
✔ |
2335 |
2335 - POWER ON – PRESS and HOLD Select button u... |
Instruction |
|
|
✔ |
2336 |
2336 - WAIT for instrument to complete self-test ... |
Instruction |
|
|
✔ |
2337 |
2337 - WAIT for instrument to complete stabilization |
Instruction |
2342 - 2337 - WAIT for instrument to complete stabilization; Remark:2300 |
|
✔ |
2338 |
2338 - VERIFY Audible Dose Rate Indicator (ADI) is on (green backli... |
Instruction |
2343 - 2338 - VERIFY Audible Dose Rate Indicator (ADI) is on (green backli...; Remark:2324 |
STEP: 2343 - 2338 - VERIFY Audible Dose Rate Indicator (ADI) is on (green backli...; Remark:2324 Smiths Detection RadSeeker CS |
✔ |
2339 |
2339 - 614 - VERIFY sufficient battery charge; Remark:2297 |
Procedure Step |
|
|
✔ |
2340 |
2340 - 220 - Power on instrument; Remark:2298 |
Procedure Step |
|
|
✔ |
2341 |
2341 - 612 - Wait for instrument to complete start-up sequence; Remark:3484 |
Procedure Step |
|
|
✔ |
2342 |
2342 - 2337 - WAIT for instrument to complete stabilization; Remark:2300 |
Procedure Step |
|
|
✔ |
2343 |
2343 - 2338 - VERIFY Audible Dose Rate Indicator (ADI) is on (green backli...; Remark:2324 |
Procedure Step |
|
|
✔ |
2344 |
2344 - SCAN close to item (5 to 10 cm) MOVE |
Instruction |
|
|
✔ |
2345 |
2345 - PRESS ENTER to acknowledge alarms |
Instruction |
2347 - 2345 - PRESS ENTER to acknowledge alarms; Remark:3485 |
STEP: 2347 - 2345 - PRESS ENTER to acknowledge alarms; Remark:3485 Smiths Detection RadSeeker CS |
✔ |
2346 |
2346 - 115 - SURVEY close to surface of item (5-10 centimeters); Remark: |
Procedure Step |
|
|
✔ |
2347 |
2347 - 2345 - PRESS ENTER to acknowledge alarms; Remark:3485 |
Procedure Step |
|
|
✔ |
2348 |
2348 - 2295 - Verify sufficient battery charge; Remark:2301 |
Procedure Step |
|
|
✔ |
2349 |
2349 - Verify successful completion of self-test |
Instruction |
2461 - 2349 - Verify successful completion of self-test; Remark:2304 |
|
✔ |
2352 |
2352 - Verify Audible Dose Rate Indicator (ADI) is on |
Instruction |
2465 - 2352 - Verify Audible Dose Rate Indicator (ADI) is on; Remark:2308 3513 - 2352 - Verify Audible Dose Rate Indicator (ADI) is on; Remark:3502 |
STEP: 2465 - 2352 - Verify Audible Dose Rate Indicator (ADI) is on; Remark:2308 RadSeeker Operation
STEP: 3513 - 2352 - Verify Audible Dose Rate Indicator (ADI) is on; Remark:3502 RadSeeker Operational Test |
✔ |
2353 |
2353 - Observe display and listen for audible alarms or vibration |
Instruction |
2467 - 2353 - Observe display and listen for audible alarms or vibration; Remark:2310 |
STEP: 2467 - 2353 - Observe display and listen for audible alarms or vibration; Remark:2310 RadSeeker Operation |
✔ |
2354 |
2354 - ACKNOWLEDGE alarms |
Instruction |
4156 - 2354 - ACKNOWLEDGE alarms; Remark:4177 |
STEP: 4156 - 2354 - ACKNOWLEDGE alarms; Remark:4177 FHT 1377 PackEye Trimble |
✔ |
2357 |
2357 - Acknowledge alarms |
Instruction |
2468 - 2357 - Acknowledge alarms; Remark:2312 2492 - 2357 - Acknowledge alarms; Remark:2326 3996 - 2357 - Potvrďte alarmy; Remark:3956 4014 - 2357 - Potvrďte alarmy; Remark:4010 4104 - 2357 - Potvrďte alarmy; Remark:4079 4958 - 2357 - Acknowledge alarms; Remark:4957 |
STEP: 2468 - 2357 - Acknowledge alarms; Remark:2312 RadSeeker Operation
STEP: 2492 - 2357 - Acknowledge alarms; Remark:2326 RadSeeker Operation RadSeeker Operational Test
STEP: 3996 - 2357 - Potvrďte alarmy; Remark:3956 PackEye Operation
STEP: 4014 - 2357 - Potvrďte alarmy; Remark:4010 PackEye Mobile App Operation
STEP: 4104 - 2357 - Potvrďte alarmy; Remark:4079 PackEye Trimble Operation
STEP: 4958 - 2357 - Acknowledge alarms; Remark:4957 RadEye PRD-ER Operation |
✔ |
2358 |
2358 - Add identification time (if needed) |
Instruction |
2494 - 2358 - Add identification time (if needed); Remark:2327 |
STEP: 2494 - 2358 - Add identification time (if needed); Remark:2327 RadSeeker Operation |
✔ |
2359 |
2359 - Return to Detect mode |
Instruction |
2495 - 2359 - Return to Detect mode; Remark:2317 3523 - 2359 - Press Select button to return to Detect mode if additional time is not necess...; Remark:3496 |
STEP: 2495 - 2359 - Return to Detect mode; Remark:2317 RadSeeker Operation |
✔ |
2360 |
2360 - Caution : Temperature must be above -15°C for instrument to start. Do not operate the ... |
Annotation |
2460 - 220 - Power on instrument; Remark:2303 |
STEP: 2460 - 220 - Power on instrument; Remark:2303 RadSeeker Operation RadSeeker Operational Test |
✔ |
2361 |
2361—Note : After 1 minute of inactivity, the instrument screen will become black, except... |
Annotation |
|
|
✔ |
2362 |
2362 - Note : The instrument automatically saves identification results. |
Annotation |
2485 - 3545 - Document event number for later reference; Remark:3487 |
STEP: 2485 - 3545 - Document event number for later reference; Remark:3487 RadSeeker Operation |
✔ |
2363 |
2363 - Note : Additional identification time may be needed due to a weak radioactive source... |
Annotation |
2494 - 2358 - Add identification time (if needed); Remark:2327 |
STEP: 2494 - 2358 - Add identification time (if needed); Remark:2327 RadSeeker Operation |
✔ |
2364 |
2364 - Shut Down Instrument |
Instruction |
2366 - 2364 - Shut Down Instrument; Remark: |
STEP: 2366 - 2364 - Shut Down Instrument; Remark: VeriFinder Operation |
✔ |
2365 |
2365 - Offload Spectra Onto Computer |
Instruction |
2367 - 2365 - Offload Spectra Onto Computer; Remark: |
STEP: 2367 - 2365 - Offload Spectra Onto Computer; Remark: VeriFinder Operation |
✔ |
2366 |
2366 - 2364 - Shut Down Instrument; Remark: |
Procedure Step |
|
|
✔ |
2367 |
2367 - 2365 - Offload Spectra Onto Computer; Remark: |
Procedure Step |
|
|
✔ |
2368 |
2368 - 257 - Prepare instrument; Remark: |
Procedure Step |
|
|
✔ |
2370 |
2370 - Connect to charger |
Instruction |
2458 - 2370 - Connect to charger; Remark:2416 10792 - 2370 - Connect to charger; Remark:10787 |
STEP: 2458 - 2370 - Connect to charger; Remark:2416 VeriFinder Operation
STEP: 10792 - 2370 - Connect to charger; Remark:10787 radEAGLET Operation |
✔ |
2371 |
2371 - Press and hold POWER/SELECT button for 5 seconds |
Instruction |
2457 - 2371 - Press and hold POWER/SELECT button for 5 seconds; Remark:652 |
STEP: 2457 - 2371 - Press and hold POWER/SELECT button for 5 seconds; Remark:652 VeriFinder Operation |
✔ |
2372 |
2372 - Remove USB flash drive from VeriFinder and connect to computer to obtain spec... |
Instruction |
2456 - 2372 - Remove USB flash drive from VeriFinder and connect to computer to obtain spec...; Remark:2415 |
STEP: 2456 - 2372 - Remove USB flash drive from VeriFinder and connect to computer to obtain spec...; Remark:2415 VeriFinder Operation |
✔ |
2373 |
2373 - Wait for files to save |
Instruction |
2454 - 2373 - Wait for files to save; Remark:2413 |
STEP: 2454 - 2373 - Wait for files to save; Remark:2413 VeriFinder Operation |
✔ |
2374 |
2374 - Press DOWN button to highlight Save to USB Drive and press P... |
Instruction |
2453 - 2374 - Press DOWN button to highlight Save to USB Drive and press P...; Remark:2412 |
STEP: 2453 - 2374 - Press DOWN button to highlight Save to USB Drive and press P...; Remark:2412 VeriFinder Operation |
✔ |
2375 |
2375 - Connect USB flash memory drive to instrument using accessory cable |
Instruction |
2452 - 2375 - Connect USB flash memory drive to instrument using accessory cable; Remark:2411 |
STEP: 2452 - 2375 - Connect USB flash memory drive to instrument using accessory cable; Remark:2411 VeriFinder Operation |
✔ |
2376 |
2376 - Press POWER/SELECT button to see a list of actions |
Instruction |
2451 - 2376 - Press POWER/SELECT button to see a list of actions; Remark:664 |
STEP: 2451 - 2376 - Press POWER/SELECT button to see a list of actions; Remark:664 VeriFinder Operation |
✔ |
2377 |
2377 - Press POWER/SELECT to acknowledge alarm, if necessary |
Instruction |
2449 - 2377 - Press POWER/SELECT to acknowledge alarm, if necessary; Remark:2409 |
STEP: 2449 - 2377 - Press POWER/SELECT to acknowledge alarm, if necessary; Remark:2409 VeriFinder Operation |
✔ |
2378 |
2378 - Press POWER/SELECT button to start identification |
Instruction |
2447 - 2378 - Press POWER/SELECT button to start identification; Remark:657 |
STEP: 2447 - 2378 - Press POWER/SELECT button to start identification; Remark:657 VeriFinder Operation |
✔ |
2379 |
2379 - Acknowledge instrument alarm by pressing POWER/SELECT button (as needed and o... |
Instruction |
2445 - 2379 - Acknowledge instrument alarm by pressing POWER/SELECT button (as needed and o...; Remark:2407 |
STEP: 2445 - 2379 - Acknowledge instrument alarm by pressing POWER/SELECT button (as needed and o...; Remark:2407 VeriFinder Operation |
✔ |
2380 |
2380 - Observe display and listen to audible indicator (if enabled) |
Instruction |
2444 - 2380 - Observe display and listen to audible indicator (if enabled); Remark:655 |
STEP: 2444 - 2380 - Observe display and listen to audible indicator (if enabled); Remark:655 VeriFinder Operation |
✔ |
2381 |
2381 - Enable audible indicator by pressing and holding BACK button until clicking s... |
Instruction |
2442 - 2381 - Enable audible indicator by pressing and holding BACK button until clicking s...; Remark:653 |
STEP: 2442 - 2381 - Enable audible indicator by pressing and holding BACK button until clicking s...; Remark:653 VeriFinder Operation |
✔ |
2382 |
2382 - Press POWER/SELECT button to accept background or press BACK button to reject... |
Instruction |
2441 - 2382 - Press POWER/SELECT button to accept background or press BACK button to reject...; Remark:2405 |
STEP: 2441 - 2382 - Press POWER/SELECT button to accept background or press BACK button to reject...; Remark:2405 VeriFinder Operation |
✔ |
2383 |
2383 - Press BACK button after viewing analysis |
Instruction |
2440 - 2383 - Press BACK button after viewing analysis; Remark:2403 |
STEP: 2440 - 2383 - Press BACK button after viewing analysis; Remark:2403 VeriFinder Operation |
✔ |
2384 |
2384 - Press DOWN button to view analysis |
Instruction |
2439 - 2384 - Press DOWN button to view analysis; Remark:2402 |
STEP: 2439 - 2384 - Press DOWN button to view analysis; Remark:2402 VeriFinder Operation |
✔ |
2385 |
2385 - Press POWER/SELECT button to start background collection |
Instruction |
2437 - 2385 - Press POWER/SELECT button to start background collection; Remark:2400 |
STEP: 2437 - 2385 - Press POWER/SELECT button to start background collection; Remark:2400 VeriFinder Operation |
✔ |
2386 |
2386 - Press POWER/SELECT button to select Background |
Instruction |
2436 - 2386 - Press POWER/SELECT button to select Background; Remark:2399 |
STEP: 2436 - 2386 - Press POWER/SELECT button to select Background; Remark:2399 VeriFinder Operation |
✔ |
2387 |
2387 - Press POWER/SELECT button to select user settings |
Instruction |
2435 - 2387 - Press POWER/SELECT button to select user settings; Remark: |
STEP: 2435 - 2387 - Press POWER/SELECT button to select user settings; Remark: VeriFinder Operation |
✔ |
2388 |
2388 - Press DOWN button to scroll to user settings icon |
Instruction |
2434 - 2388 - Press DOWN button to scroll to user settings icon; Remark:2397 |
STEP: 2434 - 2388 - Press DOWN button to scroll to user settings icon; Remark:2397 VeriFinder Operation |
✔ |
2389 |
2389 - Press BACK button to open the menu bar |
Instruction |
2433 - 2389 - Press BACK button to open the menu bar; Remark:2396 |
STEP: 2433 - 2389 - Press BACK button to open the menu bar; Remark:2396 VeriFinder Operation |
✔ |
2390 |
2390 - Press POWER/SELECT button to acknowledge “New Background Needed” message,... |
Instruction |
2428 - 2390 - Press POWER/SELECT button to acknowledge “New Background Needed” message,...; Remark:2392 |
STEP: 2428 - 2390 - Press POWER/SELECT button to acknowledge “New Background Needed” message,...; Remark:2392 VeriFinder Operation |
✔ |
2391 |
2391 - Press and hold POWER/SELECT button for 3 seconds |
Instruction |
2426 - 2391 - Press and hold POWER/SELECT button for 3 seconds; Remark:652 |
STEP: 2426 - 2391 - Press and hold POWER/SELECT button for 3 seconds; Remark:652 VeriFinder Operation |
✔ |
2392 |
2392 - The instrument will display a reminder during the start-up sequence if it has... |
Remark |
2428 - 2390 - Press POWER/SELECT button to acknowledge “New Background Needed” message,...; Remark:2392 |
STEP: 2428 - 2390 - Press POWER/SELECT button to acknowledge “New Background Needed” message,...; Remark:2392 VeriFinder Operation |
✔ |
2393 |
2393 - IO VeriFinder Display Stabilizing |
Remark |
2427 - 612 - Wait for instrument to complete start-up sequence; Remark:2393 |
STEP: 2427 - 612 - Wait for instrument to complete start-up sequence; Remark:2393 VeriFinder Operation |
✔ |
2394 |
2394 - IO VeriFinder Headphone Connection Port |
Remark |
2430 - 2206 - Connect headphones (optional); Remark:2394 |
STEP: 2430 - 2206 - Connect headphones (optional); Remark:2394 VeriFinder Operation |
✔ |
2395 |
2395 - The instrument should be located near the secondary inspection area, in simil... |
Remark |
2432 - 2209 - Verify instrument is in a suitable background radiation area; Remark:2395 |
STEP: 2432 - 2209 - Verify instrument is in a suitable background radiation area; Remark:2395 VeriFinder Operation RS-350 Operation |
✔ |
2396 |
2396 - IO VeriFinder Display Menu on Bar |
Remark |
2433 - 2389 - Press BACK button to open the menu bar; Remark:2396 |
STEP: 2433 - 2389 - Press BACK button to open the menu bar; Remark:2396 VeriFinder Operation |
✔ |
2397 |
2397 - IO VeriFinder Display Gear Icon for Settings |
Remark |
2434 - 2388 - Press DOWN button to scroll to user settings icon; Remark:2397 |
STEP: 2434 - 2388 - Press DOWN button to scroll to user settings icon; Remark:2397 VeriFinder Operation |
✔ |
2398 |
2398 - IO VeriFinder DOWN Button on Right |
Remark |
2434 - 2388 - Press DOWN button to scroll to user settings icon; Remark:2397 |
STEP: 2434 - 2388 - Press DOWN button to scroll to user settings icon; Remark:2397 VeriFinder Operation |
✔ |
2399 |
2399 - IO VeriFinder Display Background Option in Menu |
Remark |
2436 - 2386 - Press POWER/SELECT button to select Background; Remark:2399 |
STEP: 2436 - 2386 - Press POWER/SELECT button to select Background; Remark:2399 VeriFinder Operation |
✔ |
2400 |
2400 - IO VeriFinder Display Collect New on Bar |
Remark |
2437 - 2385 - Press POWER/SELECT button to start background collection; Remark:2400 |
STEP: 2437 - 2385 - Press POWER/SELECT button to start background collection; Remark:2400 VeriFinder Operation |
✔ |
2401 |
2401 - The blue bar on the left shows the time remaining. |
Remark |
2438 - 2220 - Wait for measurement to complete; Remark:2401 |
STEP: 2438 - 2220 - Wait for measurement to complete; Remark:2401 VeriFinder Operation |
✔ |
2402 |
2402 - IO VeriFinder Display Analysis on Bar |
Remark |
2439 - 2384 - Press DOWN button to view analysis; Remark:2402 |
STEP: 2439 - 2384 - Press DOWN button to view analysis; Remark:2402 VeriFinder Operation |
✔ |
2403 |
2403 - This analysis only shows naturally occurring isotopes and can be accepted. |
Remark |
2440 - 2383 - Press BACK button after viewing analysis; Remark:2403 |
STEP: 2440 - 2383 - Press BACK button after viewing analysis; Remark:2403 VeriFinder Operation |
✔ |
2404 |
2404 - This analysis shows an industrial isotope and should be rejected. |
Remark |
2440 - 2383 - Press BACK button after viewing analysis; Remark:2403 |
STEP: 2440 - 2383 - Press BACK button after viewing analysis; Remark:2403 VeriFinder Operation |
✔ |
2405 |
2405 - IO VeriFinder Display Accept on Bar |
Remark |
2441 - 2382 - Press POWER/SELECT button to accept background or press BACK button to reject...; Remark:2405 |
STEP: 2441 - 2382 - Press POWER/SELECT button to accept background or press BACK button to reject...; Remark:2405 VeriFinder Operation |
✔ |
2406 |
2406 - Keep the instrument close to the conveyance, object, or person being assessed... |
Remark |
2443 - 2215 - Survey slowly over entire item; Remark:2406 |
STEP: 2443 - 2215 - Survey slowly over entire item; Remark:2406 VeriFinder Operation |
✔ |
2407 |
2407 - Acknowledging the alarm will stop the sound and vibration. |
Remark |
2445 - 2379 - Acknowledge instrument alarm by pressing POWER/SELECT button (as needed and o...; Remark:2407 |
STEP: 2445 - 2379 - Acknowledge instrument alarm by pressing POWER/SELECT button (as needed and o...; Remark:2407 VeriFinder Operation |
✔ |
2408 |
2408 - The blue bar on the left shows the time remaining. |
Remark |
2448 - 2220 - Wait for measurement to complete; Remark:2408 |
STEP: 2448 - 2220 - Wait for measurement to complete; Remark:2408 VeriFinder Operation |
✔ |
2409 |
2409 - If an identification is made, the VeriFinder generates an alarm (threat or in... |
Remark |
2449 - 2377 - Press POWER/SELECT to acknowledge alarm, if necessary; Remark:2409 |
STEP: 2449 - 2377 - Press POWER/SELECT to acknowledge alarm, if necessary; Remark:2409 VeriFinder Operation |
✔ |