881 |
881 - Connect instrument to external power |
Instruction |
882 - 881 - Connect instrument to external power; Remark:880 882 - 881 - Connect instrument to external power; Remark:880 1988 - 881 - Connect instrument to external power; Remark:1949 |
STEP: 882 - 881 - Connect instrument to external power; Remark:880 AT6101C Operation Windows AT6101C Operation Windows
STEP: 1988 - 881 - Connect instrument to external power; Remark:1949 AT6101C Operation Android |
✔ |
882 |
882 - 881 - Connect instrument to external power; Remark:880 |
Procedure Step |
|
|
✔ |
883 |
883 - Note : Headphones can be used in a noisy environment or for discrete operation. ... |
Annotation |
804 - 803 - Prepare Atomtex for Operation; Remark: 1939 - 803 - Prepare Atomtex for Operation; Remark: |
STEP: 804 - 803 - Prepare Atomtex for Operation; Remark: AT6101C Operation Windows
STEP: 1939 - 803 - Prepare Atomtex for Operation; Remark: AT6101C Operation Android |
✔ |
884 |
884 - Power on handheld computer |
Instruction |
|
|
✔ |
885 |
885 - Use a small Phillips (PH1) screwdriver. Retain screws. |
Remark |
886 - 445 - Remove four (4) mounting screws; Remark:885 |
STEP: 886 - 445 - Remove four (4) mounting screws; Remark:885 PRM-470 PRCB-472 Board Replacement |
✔ |
886 |
886 - 445 - Remove four (4) mounting screws; Remark:885 |
Procedure Step |
|
|
✔ |
887 |
887 - Reminder : Temperature range for operation of the handheld computer is -20 to 50°C.... |
Annotation |
|
Atomtex AT6101C Windows |
✔ |
888 |
888 - 778 - POWER on BT-DU3 adaptor; Remark: |
Procedure Step |
|
|
✔ |
889 |
889 - IO PG AT6101C side pocket plus Potassium source Check sample |
Remark |
919 - 777 - PLACE check sample into side pocket; Remark:889 919 - 777 - PLACE check sample into side pocket; Remark:889 |
STEP: 919 - 777 - PLACE check sample into side pocket; Remark:889 Atomtex AT6101C Windows Atomtex AT6101C Android Atomtex AT6101C Windows Atomtex AT6101C Android |
✔ |
890 |
890 - IO PG AT6101C Backpack front pocket and BT DU3 button |
Remark |
918 - 778 - POWER on BT-DU3 Adapter; Remark:890 918 - 778 - POWER on BT-DU3 Adapter; Remark:890 |
STEP: 918 - 778 - POWER on BT-DU3 Adapter; Remark:890 Atomtex AT6101C Windows Atomtex AT6101C Android Atomtex AT6101C Windows Atomtex AT6101C Android |
✔ |
891 |
891 - IO PG Nautiz Power Button Red Circle |
Remark |
|
|
✔ |
892 |
892 - IO PG ATAS Screen plus Background Timer |
Remark |
916 - ; Remark:892 916 - ; Remark:892 |
|
✔ |
893 |
893 - IO PG AT6101C Scanning Counts Red Highlight |
Remark |
915 - 781 - VERIFY backpack connection to handheld computer; Remark:893 915 - 781 - VERIFY backpack connection to handheld computer; Remark:893 |
STEP: 915 - 781 - VERIFY backpack connection to handheld computer; Remark:893 Atomtex AT6101C Windows Atomtex AT6101C Windows |
✔ |
894 |
894 - IO PG AT6101C Battery Duration Red Highlight |
Remark |
914 - 782 - VERIFY sufficient battery power is available; Remark:894 914 - 782 - VERIFY sufficient battery power is available; Remark:894 |
STEP: 914 - 782 - VERIFY sufficient battery power is available; Remark:894 Atomtex AT6101C Windows Atomtex AT6101C Windows |
✔ |
895 |
895 - IO PG AT6101C Nautiz ATAS Fn Mode Red Highlight |
Remark |
913 - 906 - VERIFY Fn at top of screen; if not, PRESS b...; Remark:895 913 - 906 - VERIFY Fn at top of screen; if not, PRESS b...; Remark:895 |
STEP: 913 - 906 - VERIFY Fn at top of screen; if not, PRESS b...; Remark:895 Atomtex AT6101C Windows Atomtex AT6101C Windows |
✔ |
896 |
896 - IO PG AT6101C ATAS Adaptive Bkgd Red Highlight |
Remark |
|
|
✔ |
897 |
897 - IO PG AT6101C Sound Buttons Red Arrow |
Remark |
911 - 908 - ADJUST volume; Remark:897 911 - 908 - ADJUST volume; Remark:897 |
STEP: 911 - 908 - ADJUST volume; Remark:897 Atomtex AT6101C Windows Atomtex AT6101C Windows |
✔ |
898 |
898 - IO PG AT6101C Scanning Mode Red Highlight |
Remark |
844 - 843 - Verify instrument is in SCANNING mode; Remark:898 930 - 921 - VERIFY SCANNING mode; Remark:898 930 - 921 - VERIFY SCANNING mode; Remark:898 |
STEP: 844 - 843 - Verify instrument is in SCANNING mode; Remark:898 AT6101C Operation Windows
STEP: 930 - 921 - VERIFY SCANNING mode; Remark:898 Atomtex AT6101C Windows Atomtex AT6101C Windows |
✔ |
899 |
899 - IO PG AT6101 Area Scan Search Person Drums |
Remark |
931 - 922 - WALK slowly in area of interest; Remark:899 931 - 922 - WALK slowly in area of interest; Remark:899 |
STEP: 931 - 922 - WALK slowly in area of interest; Remark:899 Atomtex AT6101C Windows Atomtex AT6101C Android Atomtex AT6101C Windows Atomtex AT6101C Android |
✔ |
900 |
900 - IO PG AT6101C ATAS Gamma Alarm |
Remark |
932 - 923 - OBSERVE instrument response for elevated radiation levels; Remark:900 932 - 923 - OBSERVE instrument response for elevated radiation levels; Remark:900 |
STEP: 932 - 923 - OBSERVE instrument response for elevated radiation levels; Remark:900 Atomtex AT6101C Windows Atomtex AT6101C Windows |
✔ |
901 |
901 - IO PG AT6101C Nautiz Button 2 for Identify Mode |
Remark |
934 - 925 - PRESS Up button to perform identification; Remark:901 934 - 925 - PRESS Up button to perform identification; Remark:901 |
STEP: 934 - 925 - PRESS Up button to perform identification; Remark:901 Atomtex AT6101C Windows Atomtex AT6101C Windows |
✔ |
902 |
902 - IO PG AT6101C ATAS Identifying Low Counts Red Highlight |
Remark |
935 - 2220 - Wait for measurement to complete; Remark:902 |
STEP: 935 - 2220 - Wait for measurement to complete; Remark:902 Atomtex AT6101C Windows |
✔ |
903 |
903 - IO PG AT6101C Nautiz Power OFF Sequence of 2 |
Remark |
938 - 929 - HOLD power button then tap POWER OFF on han...; Remark:903 938 - 929 - HOLD power button then tap POWER OFF on han...; Remark:903 |
STEP: 938 - 929 - HOLD power button then tap POWER OFF on han...; Remark:903 Atomtex AT6101C Windows Atomtex AT6101C Windows |
✔ |
904 |
904—Note : A smaller handheld survey instrument can be used to pinpoint the location of ... |
Annotation |
933 - 924 - LOCATE area with highest level of radiation; Remark: |
STEP: 933 - 924 - LOCATE area with highest level of radiation; Remark: Atomtex AT6101C Windows |
✔ |
905 |
905—Note : Press ▲ button to add more time. |
Annotation |
|
|
✔ |
906 |
906 - VERIFY Fn at top of screen; if not, PRESS b... |
Instruction |
913 - 906 - VERIFY Fn at top of screen; if not, PRESS b...; Remark:895 913 - 906 - VERIFY Fn at top of screen; if not, PRESS b...; Remark:895 |
STEP: 913 - 906 - VERIFY Fn at top of screen; if not, PRESS b...; Remark:895 Atomtex AT6101C Windows Atomtex AT6101C Windows |
✔ |
907 |
907 - CHOOSE background mode – Tap Menu > Scanner |
Instruction |
912 - 907 - CHOOSE background mode – Tap Menu > Scanner; Remark: |
STEP: 912 - 907 - CHOOSE background mode – Tap Menu > Scanner; Remark: Atomtex AT6101C Windows |
✔ |
908 |
908 - ADJUST volume |
Instruction |
911 - 908 - ADJUST volume; Remark:897 911 - 908 - ADJUST volume; Remark:897 2075 - 908 - ADJUST volume; Remark:3782 |
STEP: 911 - 908 - ADJUST volume; Remark:897 Atomtex AT6101C Windows Atomtex AT6101C Windows
STEP: 2075 - 908 - ADJUST volume; Remark:3782 Atomtex AT6101C Android FHT 1377 PackEye |
✔ |
909 |
909 - CHECK operation with known source of radiation |
Instruction |
910 - 909 - CHECK operation with known source of radiation; Remark: 1267 - 909 - CHECK operation with known source of radiation; Remark:1249 2076 - 909 - CHECK operation with known source of radiation; Remark: 2076 - 909 - CHECK operation with known source of radiation; Remark: |
STEP: 910 - 909 - CHECK operation with known source of radiation; Remark: Atomtex AT6101C Windows
STEP: 1267 - 909 - CHECK operation with known source of radiation; Remark:1249 Polimaster PM1703 GN/GNA
STEP: 2076 - 909 - CHECK operation with known source of radiation; Remark: Atomtex AT6101C Android Atomtex AT6101C Android |
✔ |
910 |
910 - 909 - CHECK operation with known source of radiation; Remark: |
Procedure Step |
|
|
✔ |
911 |
911 - 908 - ADJUST volume; Remark:897 |
Procedure Step |
|
|
✔ |
912 |
912 - 907 - CHOOSE background mode – Tap Menu > Scanner; Remark: |
Procedure Step |
|
|
✔ |
913 |
913 - 906 - VERIFY Fn at top of screen; if not, PRESS b...; Remark:895 |
Procedure Step |
|
|
✔ |
914 |
914 - 782 - VERIFY sufficient battery power is available; Remark:894 |
Procedure Step |
|
|
✔ |
915 |
915 - 781 - VERIFY backpack connection to handheld computer; Remark:893 |
Procedure Step |
|
|
✔ |
916 |
916 - ; Remark:892 |
Procedure Step |
|
|
✔ |
917 |
917 - 779 - POWER ON handheld computer Note: ...; Remark:920 |
Procedure Step |
|
|
✔ |
918 |
918 - 778 - POWER on BT-DU3 Adapter; Remark:890 |
Procedure Step |
|
|
✔ |
919 |
919 - 777 - PLACE check sample into side pocket; Remark:889 |
Procedure Step |
|
|
✔ |
920 |
920 - IO PG AT6101C Nautiz Power Button Red Circle |
Remark |
917 - 779 - POWER ON handheld computer Note: ...; Remark:920 917 - 779 - POWER ON handheld computer Note: ...; Remark:920 |
STEP: 917 - 779 - POWER ON handheld computer Note: ...; Remark:920 Atomtex AT6101C Windows Atomtex AT6101C Windows |
✔ |
921 |
921 - VERIFY SCANNING mode |
Instruction |
930 - 921 - VERIFY SCANNING mode; Remark:898 930 - 921 - VERIFY SCANNING mode; Remark:898 2095 - 921 - VERIFY SCANNING mode; Remark:2089 2095 - 921 - VERIFY SCANNING mode; Remark:2089 |
STEP: 930 - 921 - VERIFY SCANNING mode; Remark:898 Atomtex AT6101C Windows Atomtex AT6101C Windows
STEP: 2095 - 921 - VERIFY SCANNING mode; Remark:2089 Atomtex AT6101C Android Atomtex AT6101C Android |
✔ |
922 |
922 - WALK slowly in area of interest |
Instruction |
931 - 922 - WALK slowly in area of interest; Remark:899 931 - 922 - WALK slowly in area of interest; Remark:899 3770 - 922 - WALK slowly in area of interest; Remark:3788 4159 - 922 - WALK slowly in area of interest; Remark:4146 4392 - 922 - WALK slowly in area of interest; Remark: |
STEP: 931 - 922 - WALK slowly in area of interest; Remark:899 Atomtex AT6101C Windows Atomtex AT6101C Android Atomtex AT6101C Windows Atomtex AT6101C Android
STEP: 3770 - 922 - WALK slowly in area of interest; Remark:3788 FHT 1377 PackEye
STEP: 4159 - 922 - WALK slowly in area of interest; Remark:4146 FHT 1377 PackEye Trimble
STEP: 4392 - 922 - WALK slowly in area of interest; Remark: RSI RS-350 |
✔ |
923 |
923 - OBSERVE instrument response for elevated radiation levels |
Instruction |
932 - 923 - OBSERVE instrument response for elevated radiation levels; Remark:900 932 - 923 - OBSERVE instrument response for elevated radiation levels; Remark:900 2096 - 923 - OBSERVE instrument response for elevated radiation levels; Remark:2090 2096 - 923 - OBSERVE instrument response for elevated radiation levels; Remark:2090 3153 - 923 - OBSERVE instrument response for elevated radiation levels; Remark:3151 4391 - 923 - OBSERVE instrument response for elevated radiation levels; Remark:4805 |
STEP: 932 - 923 - OBSERVE instrument response for elevated radiation levels; Remark:900 Atomtex AT6101C Windows Atomtex AT6101C Windows
STEP: 2096 - 923 - OBSERVE instrument response for elevated radiation levels; Remark:2090 Atomtex AT6101C Android Atomtex AT6101C Android
STEP: 3153 - 923 - OBSERVE instrument response for elevated radiation levels; Remark:3151 identiFINDER 2 NG
STEP: 4391 - 923 - OBSERVE instrument response for elevated radiation levels; Remark:4805 RSI RS-350 |
✔ |
924 |
924 - LOCATE area with highest level of radiation |
Instruction |
933 - 924 - LOCATE area with highest level of radiation; Remark: 933 - 924 - LOCATE area with highest level of radiation; Remark: 2106 - 924 - LOCATE area with highest level of radiation; Remark: 3772 - 924 - LOCATE area with highest level of radiation; Remark:3790 3813 - 924 - LOCATE area with highest level of radiation; Remark:3823 4161 - 924 - LOCATE area with highest level of radiation; Remark:4148 4409 - 924 - LOCATE area with highest level of radiation; Remark:4806 |
STEP: 933 - 924 - LOCATE area with highest level of radiation; Remark: Atomtex AT6101C Windows Atomtex AT6101C Windows
STEP: 2106 - 924 - LOCATE area with highest level of radiation; Remark: Atomtex AT6101C Android
STEP: 3772 - 924 - LOCATE area with highest level of radiation; Remark:3790 FHT 1377 PackEye
STEP: 3813 - 924 - LOCATE area with highest level of radiation; Remark:3823 FHT 1377 PackEye Mobile
STEP: 4161 - 924 - LOCATE area with highest level of radiation; Remark:4148 FHT 1377 PackEye Trimble
STEP: 4409 - 924 - LOCATE area with highest level of radiation; Remark:4806 RSI RS-350 |
✔ |
925 |
925 - PRESS Up button to perform identification |
Instruction |
934 - 925 - PRESS Up button to perform identification; Remark:901 934 - 925 - PRESS Up button to perform identification; Remark:901 |
STEP: 934 - 925 - PRESS Up button to perform identification; Remark:901 Atomtex AT6101C Windows Atomtex AT6101C Windows |
✔ |
926 |
926 - WAIT for instrument to complete identification |
Instruction |
|
|
✔ |
927 |
927 - EVALUATE identification results |
Instruction |
936 - 927 - EVALUATE identification results; Remark: 936 - 927 - EVALUATE identification results; Remark: 2101 - 927 - EVALUATE identification results; Remark:2094 2101 - 927 - EVALUATE identification results; Remark:2094 3202 - 927 - EVALUATE identification results; Remark:3201 4405 - 927 - EVALUATE identification results; Remark:4808 |
STEP: 936 - 927 - EVALUATE identification results; Remark: Atomtex AT6101C Windows Atomtex AT6101C Windows
STEP: 2101 - 927 - EVALUATE identification results; Remark:2094 Atomtex AT6101C Android Atomtex AT6101C Android
STEP: 3202 - 927 - EVALUATE identification results; Remark:3201 identiFINDER 2 NG
STEP: 4405 - 927 - EVALUATE identification results; Remark:4808 RSI RS-350 |
✔ |
928 |
928 - MOVE to another location |
Instruction |
937 - 928 - MOVE to another location; Remark: 937 - 928 - MOVE to another location; Remark: |
STEP: 937 - 928 - MOVE to another location; Remark: Atomtex AT6101C Windows Atomtex AT6101C Windows |
✔ |
929 |
929 - HOLD power button then tap POWER OFF on han... |
Instruction |
938 - 929 - HOLD power button then tap POWER OFF on han...; Remark:903 938 - 929 - HOLD power button then tap POWER OFF on han...; Remark:903 |
STEP: 938 - 929 - HOLD power button then tap POWER OFF on han...; Remark:903 Atomtex AT6101C Windows Atomtex AT6101C Windows |
✔ |
930 |
930 - 921 - VERIFY SCANNING mode; Remark:898 |
Procedure Step |
|
|
✔ |
931 |
931 - 922 - WALK slowly in area of interest; Remark:899 |
Procedure Step |
|
|
✔ |
932 |
932 - 923 - OBSERVE instrument response for elevated radiation levels; Remark:900 |
Procedure Step |
|
|
✔ |
933 |
933 - 924 - LOCATE area with highest level of radiation; Remark: |
Procedure Step |
|
|
✔ |
934 |
934 - 925 - PRESS Up button to perform identification; Remark:901 |
Procedure Step |
|
|
✔ |
935 |
935 - 2220 - Wait for measurement to complete; Remark:902 |
Procedure Step |
|
|
✔ |
936 |
936 - 927 - EVALUATE identification results; Remark: |
Procedure Step |
|
|
✔ |
937 |
937 - 928 - MOVE to another location; Remark: |
Procedure Step |
|
|
✔ |
938 |
938 - 929 - HOLD power button then tap POWER OFF on han...; Remark:903 |
Procedure Step |
|
|
✔ |
939 |
939 - Press and hold the BT-DU3 Adapter PWR button until the yello... |
Remark |
940 - 1377 - Power on BT-DU3 Adapter; Remark:939 1967 - 1377 - Power on BT-DU3 Adapter; Remark:939 |
STEP: 940 - 1377 - Power on BT-DU3 Adapter; Remark:939 AT6101C Operation Windows
STEP: 1967 - 1377 - Power on BT-DU3 Adapter; Remark:939 AT6101C Operation Android |
✔ |
940 |
940 - 1377 - Power on BT-DU3 Adapter; Remark:939 |
Procedure Step |
|
|
✔ |
941 |
941 - Does instrument operate correctly? |
Remark |
|
|
✔ |
943 |
943 - Perform DET-HHD-RAP-CM06 PRM-470 Overlay Replacement. |
Remark |
|
|
✔ |
944 |
944 - Remove moisture from instrument. Insert desiccant or open instrument and allo... |
Remark |
|
|
✔ |
945 |
945 - Perform DET-HHD-RAP-CM02 PRM-470 Check Connections and Reseat Boards... |
Remark |
|
|
✔ |
947 |
947 - Replace PRCB-472 |
Troubleshoot Element Text |
|
|
✔ |
948 |
948 - Replace Overlay |
Troubleshoot Element Text |
960 - 948 - Replace Overlay - Formal Procedure, Notes: 943 |
STEP: 960 - 948 - Replace Overlay - Formal Procedure, Notes: 943 PRM-470 Troubleshooting |
✔ |
949 |
949 - Remove Moisture |
Troubleshoot Element Text |
962 - 949 - Remove Moisture - Process, Notes: 944 997 - 949 - Remove Moisture - Process, Notes: 944 |
STEP: 962 - 949 - Remove Moisture - Process, Notes: 944 PRM-470 Troubleshooting
STEP: 997 - 949 - Remove Moisture - Process, Notes: 944 PRM-470 Troubleshooting |
✔ |
950 |
950 - Operation OK? |
Troubleshoot Element Text |
954 - 950 - Operation OK? - Decision, Notes: 941 959 - 950 - Operation OK? - Decision, Notes: 941 961 - 950 - Operation OK? - Decision, Notes: 941 963 - 950 - Operation OK? - Decision, Notes: 941 2010 - 950 - Operation OK? - Decision, Notes: 1991 2012 - 950 - Operation OK? - Decision, Notes: 1991 2016 - 950 - Operation OK? - Decision, Notes: 1991 2019 - 950 - Operation OK? - Decision, Notes: 1991 2023 - 950 - Operation OK? - Decision, Notes: 1998 2025 - 950 - Operation OK? - Decision, Notes: 1998 2029 - 950 - Operation OK? - Decision, Notes: 1998 2032 - 950 - Operation OK? - Decision, Notes: 1998 2818 - 950 - Operation OK? - Decision, Notes: 941 2820 - 950 - Operation OK? - Decision, Notes: 941 2822 - 950 - Operation OK? - Decision, Notes: 941 2828 - 950 - Operation OK? - Decision, Notes: 941 2832 - 950 - Operation OK? - Decision, Notes: 941 2839 - 950 - Operation OK? - Decision, Notes: 941 2841 - 950 - Operation OK? - Decision, Notes: 941 2843 - 950 - Operation OK? - Decision, Notes: 941 2845 - 950 - Operation OK? - Decision, Notes: 941 2847 - 950 - Operation OK? - Decision, Notes: 941 |
STEP: 954 - 950 - Operation OK? - Decision, Notes: 941 PRM-470 Troubleshooting
STEP: 959 - 950 - Operation OK? - Decision, Notes: 941 PRM-470 Troubleshooting
STEP: 961 - 950 - Operation OK? - Decision, Notes: 941 PRM-470 Troubleshooting
STEP: 963 - 950 - Operation OK? - Decision, Notes: 941 PRM-470 Troubleshooting
STEP: 2010 - 950 - Operation OK? - Decision, Notes: 1991 Atomtex AT6101C Backpack Radiation Detector
STEP: 2012 - 950 - Operation OK? - Decision, Notes: 1991 Atomtex AT6101C Backpack Radiation Detector
STEP: 2016 - 950 - Operation OK? - Decision, Notes: 1991 Atomtex AT6101C Backpack Radiation Detector
STEP: 2019 - 950 - Operation OK? - Decision, Notes: 1991 Atomtex AT6101C Backpack Radiation Detector
STEP: 2023 - 950 - Operation OK? - Decision, Notes: 1998 Atomtex AT6101C Backpack Radiation Detector
STEP: 2025 - 950 - Operation OK? - Decision, Notes: 1998 Atomtex AT6101C Backpack Radiation Detector
STEP: 2029 - 950 - Operation OK? - Decision, Notes: 1998 Atomtex AT6101C Backpack Radiation Detector
STEP: 2032 - 950 - Operation OK? - Decision, Notes: 1998 Atomtex AT6101C Backpack Radiation Detector
STEP: 2818 - 950 - Operation OK? - Decision, Notes: 941 Radiation Pager
STEP: 2820 - 950 - Operation OK? - Decision, Notes: 941 Radiation Pager
STEP: 2822 - 950 - Operation OK? - Decision, Notes: 941 Radiation Pager
STEP: 2828 - 950 - Operation OK? - Decision, Notes: 941 Radiation Pager
STEP: 2832 - 950 - Operation OK? - Decision, Notes: 941 Radiation Pager
STEP: 2839 - 950 - Operation OK? - Decision, Notes: 941 Radiation Pager
STEP: 2841 - 950 - Operation OK? - Decision, Notes: 941 Radiation Pager
STEP: 2843 - 950 - Operation OK? - Decision, Notes: 941 Radiation Pager
STEP: 2845 - 950 - Operation OK? - Decision, Notes: 941 Radiation Pager
STEP: 2847 - 950 - Operation OK? - Decision, Notes: 941 Radiation Pager |
✔ |
951 |
951 - Check Connections |
Troubleshoot Element Text |
2018 - 951 - Check Connections - Formal Procedure, Notes: 1996 2031 - 951 - Check Connections - Formal Procedure, Notes: 1996 |
STEP: 2018 - 951 - Check Connections - Formal Procedure, Notes: 1996 Atomtex AT6101C Backpack Radiation Detector
STEP: 2031 - 951 - Check Connections - Formal Procedure, Notes: 1996 Atomtex AT6101C Backpack Radiation Detector |
✔ |
955 |
955 - Contact expert support for further guidance. |
Remark |
|
|
✔ |
956 |
956 - Contact Expert Support |
Troubleshoot Element Text |
560 - 956 - Contact Expert Support - Incomplete, Notes: 548 953 - 956 - Contact Expert Support - Incomplete, Notes: 955 957 - 956 - Contact Expert Support - Incomplete, Notes: 955 985 - 956 - Contact Expert Support - Incomplete, Notes: 955 1320 - 956 - Contact Expert Support - Incomplete, Notes: 955 1545 - 956 - Contact Expert Support - Incomplete, Notes: 955 1904 - 956 - Contact Expert Support - Incomplete, Notes: 955 1905 - 956 - Contact Expert Support - Incomplete, Notes: 955 1906 - 956 - Contact Expert Support - Incomplete, Notes: 955 1907 - 956 - Contact Expert Support - Incomplete, Notes: 955 2817 - 956 - Contact Expert Support - Incomplete, Notes: 955 2827 - 956 - Contact Expert Support - Incomplete, Notes: 955 2838 - 956 - Contact Expert Support - Incomplete, Notes: 955 |
STEP: 560 - 956 - Contact Expert Support - Incomplete, Notes: 548 PRM-470 Troubleshooting
STEP: 957 - 956 - Contact Expert Support - Incomplete, Notes: 955 PRM-470 Troubleshooting
STEP: 985 - 956 - Contact Expert Support - Incomplete, Notes: 955 PRM-470 Troubleshooting
STEP: 1320 - 956 - Contact Expert Support - Incomplete, Notes: 955 PRM-470 Troubleshooting
STEP: 1545 - 956 - Contact Expert Support - Incomplete, Notes: 955 Atomtex AT6101C Backpack Radiation Detector
STEP: 1904 - 956 - Contact Expert Support - Incomplete, Notes: 955 Atomtex AT6101C Backpack Radiation Detector
STEP: 1905 - 956 - Contact Expert Support - Incomplete, Notes: 955 Atomtex AT6101C Backpack Radiation Detector
STEP: 1906 - 956 - Contact Expert Support - Incomplete, Notes: 955 Atomtex AT6101C Backpack Radiation Detector
STEP: 1907 - 956 - Contact Expert Support - Incomplete, Notes: 955 Atomtex AT6101C Backpack Radiation Detector
STEP: 2817 - 956 - Contact Expert Support - Incomplete, Notes: 955 Radiation Pager
STEP: 2827 - 956 - Contact Expert Support - Incomplete, Notes: 955 Radiation Pager
STEP: 2838 - 956 - Contact Expert Support - Incomplete, Notes: 955 Radiation Pager |
✔ |
967 |
967 - Proceed to troubleshooting flowchart 4.0 Neutron Fault |
Remark |
|
|
✔ |
968 |
968 - Are the symptoms resolved? |
Remark |
|
|
✔ |
969 |
969 - Perform DET-HHD-RAP-RM03 PRM-470 Settings Verification. |
Remark |
|
|
✔ |
970 |
970 - Perform DET-HHD-RAP-RM02 PRM-470 Computer Connection. |
Remark |
|
|
✔ |
971 |
971 - Does the instrument indicate a neutron high fault? |
Remark |
|
|
✔ |
972 |
972 - Fully charge the battery. The charger LED will indicate when charging is comp... |
Remark |
|
|
✔ |
973 |
973 - Computer Connection |
Troubleshoot Element Text |
1005 - 973 - Computer Connection - Formal Procedure, Notes: 970 |
STEP: 1005 - 973 - Computer Connection - Formal Procedure, Notes: 970 PRM-470 Troubleshooting |
✔ |
974 |
974 - Settings Verification |
Troubleshoot Element Text |
1004 - 974 - Settings Verification - Formal Procedure, Notes: 969 6882 - 974 - Settings Verification - Formal Procedure, Notes: 6877 |
STEP: 1004 - 974 - Settings Verification - Formal Procedure, Notes: 969 PRM-470 Troubleshooting
STEP: 6882 - 974 - Settings Verification - Formal Procedure, Notes: 6877 PackEye Radiation Detector Backpack |
✔ |
975 |
975 - Resolved? |
Troubleshoot Element Text |
986 - 975 - Resolved? - Decision, Notes: 968 989 - 975 - Resolved? - Decision, Notes: 968 991 - 975 - Resolved? - Decision, Notes: 968 996 - 975 - Resolved? - Decision, Notes: 968 998 - 975 - Resolved? - Decision, Notes: 968 1000 - 975 - Resolved? - Decision, Notes: 968 1003 - 975 - Resolved? - Decision, Notes: 968 1321 - 975 - Resolved? - Decision, Notes: 968 1323 - 975 - Resolved? - Decision, Notes: 968 |
STEP: 986 - 975 - Resolved? - Decision, Notes: 968 PRM-470 Troubleshooting
STEP: 989 - 975 - Resolved? - Decision, Notes: 968 PRM-470 Troubleshooting
STEP: 991 - 975 - Resolved? - Decision, Notes: 968 PRM-470 Troubleshooting
STEP: 996 - 975 - Resolved? - Decision, Notes: 968 PRM-470 Troubleshooting
STEP: 998 - 975 - Resolved? - Decision, Notes: 968 PRM-470 Troubleshooting
STEP: 1000 - 975 - Resolved? - Decision, Notes: 968 PRM-470 Troubleshooting
STEP: 1003 - 975 - Resolved? - Decision, Notes: 968 PRM-470 Troubleshooting
STEP: 1321 - 975 - Resolved? - Decision, Notes: 968 PRM-470 Troubleshooting
STEP: 1323 - 975 - Resolved? - Decision, Notes: 968 PRM-470 Troubleshooting |
✔ |
976 |
976 - Check Connections and Reseat Boards |
Troubleshoot Element Text |
1002 - 976 - Check Connections and Reseat Boards - Formal Procedure, Notes: 507 |
STEP: 1002 - 976 - Check Connections and Reseat Boards - Formal Procedure, Notes: 507 PRM-470 Troubleshooting |
✔ |
977 |
977 - Neutron Fault? |
Troubleshoot Element Text |
995 - 977 - Neutron Fault? - Decision, Notes: 971 |
STEP: 995 - 977 - Neutron Fault? - Decision, Notes: 971 PRM-470 Troubleshooting |
✔ |
978 |
978 - Gamma Alignment |
Troubleshoot Element Text |
987 - 978 - Gamma Alignment - Formal Procedure, Notes: 980 990 - 978 - Gamma Alignment - Formal Procedure, Notes: 980 |
STEP: 987 - 978 - Gamma Alignment - Formal Procedure, Notes: 980 PRM-470 Troubleshooting
STEP: 990 - 978 - Gamma Alignment - Formal Procedure, Notes: 980 PRM-470 Troubleshooting |
✔ |
979 |
979 - Replace GHA-472 |
Troubleshoot Element Text |
988 - 979 - Replace GHA-472 - Formal Procedure, Notes: 981 |
STEP: 988 - 979 - Replace GHA-472 - Formal Procedure, Notes: 981 PRM-470 Troubleshooting |
✔ |
980 |
980 - Perform DET-HHD-RAP-CM03 PRM-470 Gamma Alignment. |
Remark |
|
|
✔ |
981 |
981 - Perform DET-HHD-RAP-CM04 PRM-470 GHA-472 Board Replacement. |
Remark |
|
|
✔ |
983 |
983 - Perform DET-HHD-RAP-CM01 PRM-470 Battery Replacement. |
Remark |
|
|
✔ |
993 |
993 - 4.0 Neutron Flowchart |
Troubleshoot Element Text |
994 - 993 - 4.0 - Section Reference, Notes: 967 |
STEP: 994 - 993 - 4.0 - Section Reference, Notes: 967 PRM-470 Troubleshooting |
✔ |
1010 |
1010 - Note : Use DET-HHD-YAN-RM02, MKC-A03 Functional Test, to verify equipment f... |
Annotation |
1012 - 257 - Prepare instrument; Remark: |
STEP: 1012 - 257 - Prepare instrument; Remark: Aspect MKC-A03 Operation |
✔ |
1012 |
1012 - 257 - Prepare instrument; Remark: |
Procedure Step |
|
|
✔ |
1013 |
1013 - Aspect MKC-A03 and docking station |
Remark |
1015 - 1014 - Apply power to docking station; Remark:1013 1015 - 1014 - Apply power to docking station; Remark:1013 |
STEP: 1015 - 1014 - Apply power to docking station; Remark:1013 Aspect MKC-A03 Operation Aspect MKC-A03 Operation |
✔ |
1014 |
1014 - Apply power to docking station |
Instruction |
1015 - 1014 - Apply power to docking station; Remark:1013 1015 - 1014 - Apply power to docking station; Remark:1013 |
STEP: 1015 - 1014 - Apply power to docking station; Remark:1013 Aspect MKC-A03 Operation Aspect MKC-A03 Operation |
✔ |
1015 |
1015 - 1014 - Apply power to docking station; Remark:1013 |
Procedure Step |
|
|
✔ |
1016 |
1016 - Verify no radioactive sources near instrument and docking station |
Instruction |
1017 - 1016 - Verify no radioactive sources near instrument and docking station; Remark:7 |
STEP: 1017 - 1016 - Verify no radioactive sources near instrument and docking station; Remark:7 Aspect MKC-A03 Operation |
✔ |
1017 |
1017 - 1016 - Verify no radioactive sources near instrument and docking station; Remark:7 |
Procedure Step |
|
|
✔ |
1018 |
1018 - Placing the MKC-A03 on the docking station will automatically power on the in... |
Remark |
1022 - 220 - Power on instrument; Remark:1018 |
STEP: 1022 - 220 - Power on instrument; Remark:1018 Aspect MKC-A03 Operation |
✔ |
1019 |
1019 - If the instrument does not power on automatically, press and hold the center ... |
Remark |
1022 - 220 - Power on instrument; Remark:1018 |
STEP: 1022 - 220 - Power on instrument; Remark:1018 Aspect MKC-A03 Operation |
✔ |
1020 |
1020 - Green LED shows the docking station is supplying power to the instrument.... |
Remark |
1022 - 220 - Power on instrument; Remark:1018 |
STEP: 1022 - 220 - Power on instrument; Remark:1018 Aspect MKC-A03 Operation |
✔ |
1022 |
1022 - 220 - Power on instrument; Remark:1018 |
Procedure Step |
|
|
✔ |
1023 |
1023 - Note : If instrument did not calibrate correctly or it does not pass the self-test, ... |
Annotation |
1026 - 1025 - Wait for screen to display READY status or follow on-screen instructions ...; Remark:1024 1026 - 1025 - Wait for screen to display READY status or follow on-screen instructions ...; Remark:1024 |
STEP: 1026 - 1025 - Wait for screen to display READY status or follow on-screen instructions ...; Remark:1024 Aspect MKC-A03 Operation Aspect MKC-A03 Operation |
✔ |