Last Updated: 05/06/2025 1:37 AM

The following table lists all the components that make up the document.

Title Type Status Last Updated
Smiths Detection RadSeeker CS
Device
Published
06/27/2024 12:54 PM
247 - 257 - Prepare instrument; Remark:
Procedure Step
Published
04/11/2025 9:08 PM
257 - Prepare instrument
Instruction
Published
04/11/2025 9:07 PM
786 - 219 - Verify there are no sources of radiation near instrument; Remark:7
Procedure Step
Published
04/20/2025 6:37 PM
219 - Verify there are no sources of radiation near instrument
Instruction
Published
04/12/2025 4:20 PM
7 - No Radiation symbol
Remark
Published
07/12/2021 1:34 PM
2348 - 2295 - Verify sufficient battery charge; Remark:2301
Procedure Step
Published
11/04/2020 2:35 PM
2295 - Verify sufficient battery charge
Instruction
Published
04/06/2021 4:43 PM
2301 - Open the battery cover to view the charge level indicator.
Remark
Published
07/23/2021 8:38 PM
2302 - Replace battery pack or charge instrument if fewer than two (2) bars are visi...
Remark
Published
07/27/2021 12:20 PM
2297 - IO RadSeeker 3 bar Battery
Remark
Published
10/19/2024 10:28 PM
2460 - 220 - Power on instrument; Remark:2303
Procedure Step
Published
11/04/2020 5:34 PM
2360 - Caution : Temperature must be above -15°C for instrument to start. Do not operate the ...
Annotation
Published
11/04/2020 5:27 PM
220 - Power on instrument
Instruction
Published
04/06/2025 7:00 PM
2303 - Press and hold ENTER button until display powers on (3 to 5 ...
Remark
Published
07/23/2021 8:41 PM
2298 - IO RadSeeker Button Pad Select Button Yellow Box
Remark
Published
10/21/2024 7:26 PM
2462 - 612 - Wait for instrument to complete start-up sequence; Remark:2306
Procedure Step
Published
04/13/2025 6:49 PM
612 - Wait for instrument to complete start-up sequence
Instruction
Published
04/13/2025 6:38 PM
2306 - The instrument will automatically enter Detect mode after sy...
Remark
Published
07/23/2021 8:45 PM
2463 - 319 - Perform operational test; Remark:2307
Procedure Step
Published
07/23/2021 10:00 PM
319 - Perform operational test
Instruction
Published
06/10/2021 8:31 PM
2307 - It is recommended to perform an operational test daily before use. See DET-HH...
Remark
Published
11/04/2020 5:38 PM
3495 - 3494 - Collect background measurement; Remark:
Procedure Step
Published
07/27/2021 7:21 PM
3494 - Collect background measurement
Instruction
Published
08/27/2024 5:25 PM
3532 - 3525 - Navigate to Menu; Remark:3526
Procedure Step
Published
07/29/2021 9:55 AM
3525 - Navigate to Menu
Instruction
Published
07/29/2021 6:41 AM
3526 - Press DOWN to select Menu.
Remark
Published
07/29/2021 6:42 AM
3533 - 3527 - Press ENTER to select Collect New Background; Remark:3534
Procedure Step
Published
07/29/2021 10:50 AM
3527 - Press ENTER to select Collect New Background
Instruction
Published
07/29/2021 6:52 AM
3534 - RadSeeker Menu New Background
Remark
Published
07/29/2021 10:06 AM
3535 - 2220 - Wait for measurement to complete; Remark:3528
Procedure Step
Published
04/20/2025 12:52 PM
2220 - Wait for measurement to complete
Instruction
Published
10/22/2020 11:15 AM
3528 - Progress is shown at the bottom of the screen.
Remark
Published
07/29/2021 6:54 AM
3537 - 3529 - Press ENTER to acknowledge background; Remark:3536
Procedure Step
Published
07/29/2021 10:56 AM
3529 - Press ENTER to acknowledge background
Instruction
Published
07/29/2021 7:14 AM
3536 - RadSeeker Complete Background Collection
Remark
Published
07/29/2021 10:55 AM
3538 - 3530 - Return to Detect; Remark:3531
Procedure Step
Published
07/29/2021 11:19 AM
3530 - Return to Detect
Instruction
Published
07/29/2021 7:16 AM
3531 - Scroll to Back and press ENTER.
Remark
Published
07/30/2021 2:42 PM
2464 - 365 - Locate RN material; Remark:
Procedure Step
Published
07/30/2021 2:48 PM
3539 - Note : The instrument screen will turn black after a period of inactivity; only coun...
Annotation
Published
07/30/2021 2:47 PM
365 - Locate RN material
Instruction
Published
06/10/2021 8:45 PM
2465 - 2352 - Verify Audible Dose Rate Indicator (ADI) is on; Remark:2308
Procedure Step
Published
07/23/2021 10:04 PM
2352 - Verify Audible Dose Rate Indicator (ADI) is on
Instruction
Published
07/29/2021 12:52 PM
2308 - Press the UP arrow to activate the ADI.
Remark
Published
11/04/2020 5:08 PM
7071 - 408 - Survey close to surface of item; Remark:7070
Procedure Step
Published
02/22/2023 11:22 AM
408 - Survey close to surface of item
Instruction
Published
06/10/2021 8:50 PM
7070 - Maintain a distance of approximately 5 to 10 cm from surface of item. Do not ...
Remark
Published
02/22/2023 11:21 AM
2466 - 2215 - Survey slowly over entire item; Remark:2315
Procedure Step
Published
07/23/2021 9:08 PM
2215 - Survey slowly over entire item
Instruction
Published
04/06/2021 5:07 PM
2315 - Move instrument approximately 20 cm per second. Thoroughly survey all accessi...
Remark
Published
11/04/2020 5:09 PM
2309 - IO RadSeeker Raster Scan Box
Remark
Published
11/04/2020 7:37 AM
2467 - 2353 - Observe display and listen for audible alarms or vibration; Remark:2310
Procedure Step
Published
07/23/2021 9:14 PM
2353 - Observe display and listen for audible alarms or vibration
Instruction
Published
11/04/2020 4:51 PM
2310 - Gamma Dose Rate (µSv/hr) values will increase. Gamma coun...
Remark
Published
11/04/2020 7:38 AM
2311 - IO RadSeeker Vibrate Sound Icons
Remark
Published
11/04/2020 5:11 PM
2468 - 2357 - Acknowledge alarms; Remark:2312
Procedure Step
Published
05/02/2022 10:57 AM
2357 - Acknowledge alarms
Instruction
Published
07/23/2021 9:29 PM
2312 - Press ENTER to acknowledge any alarms.
Remark
Published
07/23/2021 10:45 PM
405 - 368 - Označte podezřelá místa; Remark:4277
Procedure Step
Published
04/20/2025 5:44 PM
368 - Mark point(s) of interest
Instruction
Published
06/11/2021 9:23 AM
4277 - Place a marker (tape, pencil, etc.) on points exhibiting elevated radiation. ...
Remark
Published
04/20/2025 5:37 PM
857 - 856 - Identify Isotopes; Remark:
Procedure Step
Published
11/04/2020 6:06 PM
856 - Identify Isotopes
Instruction
Published
07/23/2021 9:20 PM
2489 - 2218 - Place instrument close to measurement location; Remark:2325
Procedure Step
Published
11/04/2020 5:45 PM
2218 - Place instrument close to measurement location
Instruction
Published
04/06/2021 5:15 PM
2325 - The instrument should be as close as possible without making contact.
Remark
Published
07/23/2021 10:42 PM
2323 - IO RadSeeker Trefoil Box Identify
Remark
Published
11/04/2020 7:40 AM
2490 - 859 - Start identification measurement; Remark:2322
Procedure Step
Published
07/23/2021 10:18 PM
859 - Start identification measurement
Instruction
Published
10/26/2020 7:00 PM
2322 - Press ENTER under Start ID.
Remark
Published
07/23/2021 10:39 PM
2491 - 2220 - Wait for measurement to complete; Remark:2321
Procedure Step
Published
04/20/2025 12:55 PM
2321 - IO RadSeeker Collecting Spectrum Wait
Remark
Published
10/21/2024 8:36 PM
2492 - 2357 - Acknowledge alarms; Remark:2326
Procedure Step
Published
11/04/2020 5:49 PM
2326 - Press ENTER to acknowledge innocent or threat alarms.
Remark
Published
07/23/2021 9:35 PM
2320 - IO RadSeeker Alarm Acknowledge Threat
Remark
Published
10/21/2024 8:40 PM
2493 - 2221 - Observe identification results; Remark:2319
Procedure Step
Published
11/04/2020 5:50 PM
2221 - Observe identification results
Instruction
Published
04/06/2021 5:20 PM
2319 - IO RadSeeker Identify Isotope Co60
Remark
Published
10/21/2024 8:42 PM
2485 - 3545 - Document event number for later reference; Remark:3487
Procedure Step
Published
08/02/2021 10:20 AM
2362 - Note : The instrument automatically saves identification results.
Annotation
Published
07/30/2021 3:01 PM
3545 - Document event number for later reference
Instruction
Published
08/02/2021 10:17 AM
3487 - IO RadSeeker Event Number
Remark
Published
07/27/2021 4:33 PM
2494 - 2358 - Add identification time (if needed); Remark:2327
Procedure Step
Published
07/30/2021 3:02 PM
2363 - Note : Additional identification time may be needed due to a weak radioactive source...
Annotation
Published
11/04/2020 5:30 PM
2358 - Add identification time (if needed)
Instruction
Published
07/30/2021 3:04 PM
2327 - Press the UP arrow to add time.
Remark
Published
07/30/2021 3:02 PM
2318 - IO RadSeeker Add Time Button
Remark
Published
11/04/2020 1:55 PM
2328 - Press DOWN to choose additional time needed. Press E...
Remark
Published
07/30/2021 3:03 PM
2495 - 2359 - Return to Detect mode; Remark:2317
Procedure Step
Published
11/04/2020 5:52 PM
2359 - Return to Detect mode
Instruction
Published
07/30/2021 3:06 PM
2317 - Press ENTER under Detect.
Remark
Published
07/23/2021 9:40 PM
399 - 375 - Document results; Remark:394
Procedure Step
Published
06/11/2021 9:46 AM
375 - Document results
Instruction
Published
06/11/2021 9:37 AM
394 - Document results per Standard Operating Procedures.
Remark
Published
06/11/2021 9:36 AM
2497 - 313 - Power off instrument; Remark:2330
Procedure Step
Published
11/04/2020 5:53 PM
313 - Power off instrument
Instruction
Published
07/23/2021 2:41 PM
2330 - Press ENTER until the screen displays Shutting down
Remark
Published
07/23/2021 9:42 PM
2316 - IO RadSeeker Shutting Down
Remark
Published
11/04/2020 4:58 PM
3544 - 3541 - Charge batteries; Remark:3542
Procedure Step
Published
07/30/2021 3:29 PM
3540 - Note : Always charge batteries when not in use.
Annotation
Published
07/30/2021 3:22 PM
3541 - Charge batteries
Instruction
Published
07/30/2021 3:22 PM
3542 - Two (2) batteries are supplied with the RadSeeker. Remove charger plug. Align...
Remark
Published
07/30/2021 3:28 PM
3543 - Batteries can also be charged using the external charger.
Remark
Published
07/30/2021 3:28 PM
Operator Procedure
Document Type
Published
03/02/2020 3:31 PM
Caution
Annotation Type
Published
03/02/2020 3:24 PM
Note
Annotation Type
Published
03/02/2020 3:25 PM
No Radiation Symbol
Image
Published
08/13/2024 2:56 PM
radseeker_di_battopen_2arrow_00659.jpg
Image
Published
10/20/2023 9:31 AM
radseeker_di_battbar_000477.jpg
Image
Published
10/18/2023 4:32 PM
radseeker_di_selectmiddle_00473.jpg
Image
Published
10/20/2023 9:35 AM
radseeker_ui_modedetect_217cps_00467.jpg
Image
Published
10/20/2023 10:15 AM
radseeker_ui_menuselectright_00667.jpg
Image
Published
10/20/2023 10:12 AM
radseeker_ui_bkgdnew_00664.jpg
Image
Published
10/20/2023 9:44 AM
radseeker_ui_bkgdprogress_00665.jpg
Image
Published
10/20/2023 9:44 AM
radseeker_ui_bkgdcomplete_00663.jpg
Image
Published
10/20/2023 9:43 AM
radseeker_menuback_00662.jpg
Image
Published
10/20/2023 9:38 AM
radseeker_ui_adiselect_00471.jpg
Image
Published
10/20/2023 9:42 AM
radseeker_di_raster_000474.jpg
Image
Published
10/18/2023 4:43 PM
radseeker_ui_increasgr_11164cps_00463.jpg
Image
Published
10/20/2023 10:07 AM
radseeker_di_audio_00472.jpg
Image
Published
10/20/2023 8:54 AM
radseeker_ui_neutronalarmack_252cps_00469.jpg
Image
Published
10/20/2023 10:17 AM
Mark_Source_Location_Trefoil
Image
Published
02/19/2023 10:54 AM
radseeker_di_pointident_000475.jpg
Image
Published
10/18/2023 4:40 PM
radseeker_ui_startid_11164cps_00458.jpg
Image
Published
10/20/2023 10:21 AM
radseeker_ui_collectspec_00468.jpg
Image
Published
10/20/2023 9:46 AM
radseeker_ui_threatack_1025cps_00457.jpg
Image
Published
10/20/2023 10:22 AM
radseeker_ui_idco60_902cps_00465.jpg
Image
Published
10/20/2023 10:06 AM
radseeker_ui_eventid_00666.jpg
Image
Published
10/20/2023 9:47 AM
radseeker_idco60addtime_00464.jpg
Image
Published
10/20/2023 9:35 AM
radseeker_idselect30sec_00461.jpg
Image
Published
10/20/2023 9:37 AM
radseeker_ui_menuselectmiddledetect_00466.jpg
Image
Published
10/20/2023 10:11 AM
radseeker_ui_shut_00460.jpg
Image
Published
10/20/2023 10:19 AM
radseeker_di_chargepluggerout_00660.jpg
Image
Published
10/20/2023 9:31 AM
radseeker_di_chargerconnect_00661.jpg
Image
Published
10/20/2023 9:32 AM
radseeker_di_battchargerstand_00658.jpg
Image
Published
10/20/2023 9:30 AM
DET-HHD-SMD-RSK-OP01

Search item of interest (conveyance, object, or person) and identify nuclear and other radioactive (RN) material.

Equipment Hierarchy
Smiths Detection RadSeeker CS
Technician Level
Duration
Materials Required
DET-HHD-SMD-RM01 RadSeeker Operational Test
Originators
Brian Tucker
Mike Demboski
Garrick Redden
Safety Concerns
None
Version #
Revision #
1.00
Revision Description

Replace display images and correct procedure numbers

Revision Author
Revision #
2.00
Revision Description

Reworded items to be more consistent with training materials

Revision Date
Revision Author
Operation
Step 1

2460 - 220 - Power on instrument; Remark:2303

Step 00
Step 2
Main Step
Search
Step 4
Main Step

2467 - 2353 - Observe display and listen for audible alarms or vibration; Remark:2310

Step 00
Identification
Step 5

2494 - 2358 - Add identification time (if needed); Remark:2327

Step 00
Step 6
Main Step
Step 8
Main Step

3544 - 3541 - Charge batteries; Remark:3542

Step 00
Document Type
Operator Procedure
Percent Complete
100.00
Percent Complete W/Media
100.00