TA600 Power Knob Adjustment

Last Updated: 04/26/2025 1:46 AM

The following table lists all the components that make up the document.

Title Type Status Last Updated
Sensor Tech TA600 Radiation Pager
Device
Published
10/28/2024 3:51 PM
11095 - 313 - Power off instrument; Remark:11093
Procedure Step
Published
10/01/2024 3:33 PM
313 - Power off instrument
Instruction
Published
07/23/2021 2:41 PM
11093 - Rotate switch to OFF position.
Remark
Published
10/01/2024 3:29 PM
11094 - TA600 Rotate switch to OFF Position
Remark
Published
10/01/2024 3:33 PM
11092 - 11091 - Uninstall power knob; Remark:
Procedure Step
Published
10/01/2024 3:35 PM
11091 - Uninstall power knob
Instruction
Published
10/01/2024 3:35 PM
11089 - 11088 - Remove set screw; Remark:11084
Procedure Step
Published
10/01/2024 5:04 PM
11088 - Remove set screw
Instruction
Published
10/01/2024 5:00 PM
11084 - Use 0.05-in. hex driver. Rotate counterclockwise.
Remark
Published
10/01/2024 5:00 PM
11085 - Remove set screw
Remark
Published
10/01/2024 5:02 PM
11086 - Retain set screw.
Remark
Published
10/01/2024 5:03 PM
11087 - Retain set screw
Remark
Published
10/01/2024 5:04 PM
11090 - 11083 - Remove knob; Remark:11079
Procedure Step
Published
10/01/2024 7:11 PM
11083 - Remove knob
Instruction
Published
10/01/2024 5:05 PM
11079 - If needed, use small, slotted screwdriver. Carefully pry up the knob using small...
Remark
Published
10/01/2024 5:05 PM
11080 - TA600 Remove knob
Remark
Published
10/01/2024 7:08 PM
11081 - TA600 Carefully pry up the knob
Remark
Published
10/01/2024 7:09 PM
11082 - TA600 Knob removed
Remark
Published
10/01/2024 7:11 PM
11078 - 11077 - Prepare for reassembly; Remark:
Procedure Step
Published
10/01/2024 7:12 PM
11077 - Prepare for reassembly
Instruction
Published
10/01/2024 7:12 PM
11074 - 11073 - Clean top housing; Remark:11071
Procedure Step
Published
10/01/2024 7:14 PM
11073 - Clean top housing
Instruction
Published
10/01/2024 7:12 PM
11071 - Use cotton swab and alcohol. Verify surfaces are free of debris, oil, and lub...
Remark
Published
10/01/2024 7:13 PM
11072 - TA600 Clean top housing
Remark
Published
10/01/2024 7:14 PM
11075 - 11070 - Clean knob; Remark:11068
Procedure Step
Published
10/01/2024 7:22 PM
11070 - Clean knob
Instruction
Published
10/01/2024 7:15 PM
11068 - Use cotton swab and alcohol. Verify surfaces are free of debris, oil, and lub...
Remark
Published
10/01/2024 7:15 PM
11069 - TA600 Clean knob
Remark
Published
10/01/2024 7:22 PM
11076 - 11067 - Lubricate O-ring; Remark:11112
Procedure Step
Published
10/01/2024 7:23 PM
11067 - Lubricate O-ring
Instruction
Published
10/01/2024 7:23 PM
11112 - Apply small amount of high viscosity silicone O-ring lubricant to O-ring on p...
Remark
Published
10/01/2024 7:33 PM
11113 - TA600 Lubricate O-ring
Remark
Published
10/01/2024 7:35 PM
11111 - 11110 - Reinstall power knob; Remark:
Procedure Step
Published
10/01/2024 7:36 PM
11110 - Reinstall power knob
Instruction
Published
10/01/2024 7:36 PM
11107 - 11105 - Place power knob; Remark:11103
Procedure Step
Published
10/01/2024 7:43 PM
11105 - Place power knob
Instruction
Published
10/01/2024 7:36 PM
11103 - Set the power knob onto the switch, but do not press down fully. Leave a gap....
Remark
Published
10/01/2024 7:37 PM
11104 - TA600 Set the power knob onto the switch
Remark
Published
10/01/2024 7:41 PM
11108 - 11102 - Insert knob spacer; Remark:11100
Procedure Step
Published
10/01/2024 7:46 PM
11106 - Note : If spacer is not available, use about four (4) sheets of paper, cut to fit aroun...
Annotation
Published
10/01/2024 7:43 PM
11102 - Insert knob spacer
Instruction
Published
10/01/2024 7:44 PM
11100 - Use 0.01-in. knob spacer. Insert spacer tool between knob and Pager housing.
Remark
Published
10/01/2024 7:44 PM
11101 - TA600 Insert knob spacer
Remark
Published
10/01/2024 7:46 PM
11109 - 11099 - Seat power knob; Remark:11097
Procedure Step
Published
10/01/2024 7:48 PM
11099 - Seat power knob
Instruction
Published
10/01/2024 7:47 PM
11097 - 1 – Verify the O (Off) is aligned with the notch on the instrument. ...
Remark
Published
10/01/2024 7:47 PM
11098 - TA600 Seat power knob
Remark
Published
10/01/2024 7:48 PM
11137 - 11136 - Apply thread locker; Remark:11134
Procedure Step
Published
10/01/2024 7:53 PM
11136 - Apply thread locker
Instruction
Published
10/01/2024 7:51 PM
11134 - 1 – To ease application, place set screw onto 0.05-in. hex driver. 2...
Remark
Published
10/01/2024 7:52 PM
11135 - TA600 Apply thread locker
Remark
Published
10/01/2024 7:53 PM
11138 - 11132 - Insert set screw; Remark:11129
Procedure Step
Published
10/01/2024 7:58 PM
11133 - Caution : Do not overtighten screw. This will make it difficult to turn power knob.
Annotation
Published
10/01/2024 7:54 PM
11132 - Insert set screw
Instruction
Published
10/01/2024 7:54 PM
11129 - Use 0.05-in. hex driver. Rotate clockwise. Insert set screw fully into knob. If ...
Remark
Published
10/01/2024 7:55 PM
11130 - TA600 Insert set screw, rotate clockwise
Remark
Published
10/01/2024 7:56 PM
11131 - TA600 Insert set screw, do not overtighten
Remark
Published
10/01/2024 7:58 PM
11139 - 11128 - Remove knob spacer; Remark:11126
Procedure Step
Published
10/01/2024 8:00 PM
11128 - Remove knob spacer
Instruction
Published
10/01/2024 7:58 PM
11126 - Slide knob spacer out from under power knob.
Remark
Published
10/01/2024 7:58 PM
11127 - TA600 Remove knob spacer
Remark
Published
10/01/2024 8:00 PM
11125 - 11124 - Verify instrument is operational; Remark:
Procedure Step
Published
10/01/2024 8:01 PM
11124 - Verify instrument is operational
Instruction
Published
10/01/2024 8:00 PM
11121 - 11120 - Verify knob alignment; Remark:11118
Procedure Step
Published
10/01/2024 8:03 PM
11120 - Verify knob alignment
Instruction
Published
10/01/2024 8:01 PM
11118 - The OFF position (0) should be centered on the notch on the instrument.
Remark
Published
10/01/2024 8:01 PM
11119 - TA600 Verify knob alignment
Remark
Published
10/01/2024 8:02 PM
11122 - 11117 - Verify knob movement; Remark:11115
Procedure Step
Published
10/01/2024 8:05 PM
11117 - Verify knob movement
Instruction
Published
10/01/2024 8:03 PM
11115 - The knob should turn easily. The knob should click into place for vibrate and...
Remark
Published
10/01/2024 8:03 PM
11116 - TA600 Verify knob movement
Remark
Published
10/01/2024 8:05 PM
11123 - 319 - Perform operational test; Remark:11114
Procedure Step
Published
10/01/2024 8:09 PM
319 - Perform operational test
Instruction
Published
06/10/2021 8:31 PM
11114 - DET-HHD-STE-TA6-RM01, TA600 Operational Test
Remark
Published
10/01/2024 8:09 PM
322 - 321 - Document maintenance actions; Remark:
Procedure Step
Published
06/17/2021 9:49 AM
321 - Document maintenance actions
Instruction
Published
04/21/2025 11:19 AM
2869 - 2585 - Document maintenance performed; Remark:2866
Procedure Step
Published
06/18/2021 5:58 PM
2585 - Document maintenance performed
Instruction
Published
07/09/2021 12:15 PM
2866 - Record observations, times, and results for the maintenance report.
Remark
Published
04/21/2025 11:39 AM
4706 - 4705 - Submit report; Remark:4864
Procedure Step
Published
06/29/2022 9:50 AM
4705 - Submit report
Instruction
Published
06/29/2022 9:50 AM
4864 - As specified by management or contractual obligations.
Remark
Published
07/28/2022 1:36 PM
Corrective Maintenance Procedure
Document Type
Published
03/02/2020 3:32 PM
minutes
Duration
Published
05/26/2022 11:41 AM
Power knob is difficult to turn
Frequency
Published
10/02/2024 6:09 AM
As Needed
Frequency
Published
04/01/2020 11:36 AM
Note
Annotation Type
Published
03/02/2020 3:25 PM
Caution
Annotation Type
Published
03/02/2020 3:24 PM
Technician 2
Skill Level
Published
04/09/2020 1:17 AM
0.05-in. hex driver
Replacement Parts
Published
10/01/2024 7:27 PM
Knob spacer, 0.01-in. U-shaped shim
Replacement Parts
Published
10/01/2024 7:27 PM
Small slotted screwdriver
Replacement Parts
Published
10/01/2024 7:27 PM
TA600 Verify Knob Alignment
Image
Published
10/01/2024 7:27 PM
Remove set screw
Image
Published
10/01/2024 7:27 PM
Retain set screw.
Image
Published
10/01/2024 7:27 PM
TA600 Remove knob
Image
Published
10/01/2024 7:27 PM
TA600 Carefully pry up the knob
Image
Published
10/01/2024 7:27 PM
TA600 Knob removed
Image
Published
10/01/2024 7:27 PM
TA600 Clean top housing
Image
Published
10/01/2024 7:27 PM
TA600 Clean knob
Image
Published
10/01/2024 7:27 PM
TA600_Lubricate O-Rrng_0.png
Image
Published
10/02/2024 9:00 AM
TA600 Set the power knob onto the switch
Image
Published
10/01/2024 7:50 PM
TA600 Insert knob spacer
Image
Published
10/01/2024 7:50 PM
TA600 Seat power knob
Image
Published
10/01/2024 7:50 PM
TA600 Apply thread locker
Image
Published
10/01/2024 8:20 PM
TA600 Insert set screw, rotate clockwise
Image
Published
10/01/2024 8:20 PM
TA600_Insert_Set_Screw_do_not_overtighten.png
Image
Published
10/01/2024 8:33 PM
TA600 Remove knob spacer
Image
Published
10/01/2024 8:20 PM
TA600 Verify knob alignment
Image
Published
10/01/2024 8:20 PM
TA600 Verify knob movement
Image
Published
10/01/2024 8:20 PM

RPM Nano Controller Replacement

Last Updated: 04/26/2025 1:44 AM

The following table lists all the components that make up the document.

Title Type Status Last Updated
Rapiscan VM-250 Vehicle Monitor
Device
Published
10/14/2024 9:50 AM
Rapiscan TM-850 Rail Monitor
Device
Published
09/18/2024 10:28 AM
8468 - 1401 - Establish Initial Conditions; Remark:
Procedure Step
Published
09/16/2023 4:47 PM
1401 - Establish Initial Conditions
Instruction
Published
09/30/2022 3:14 PM
8489 - 1401 - Establish Initial Conditions; Remark:
Procedure Step
Published
09/24/2023 9:51 AM
7265 - Warning : Traffic should temporarily be rerouted or halted during this procedure to ens...
Annotation
Published
04/27/2023 1:42 PM
8490 - 7592 - Inform system operators; Remark:
Procedure Step
Published
09/16/2023 8:49 PM
7592 - Inform system operators
Instruction
Published
06/29/2023 3:20 PM
7454 - 7290 - Disable tamper switches; Remark:7416
Procedure Step
Published
06/02/2023 5:25 PM
7290 - Disable tamper switches
Instruction
Published
05/01/2023 8:14 AM
7416 - Use a magnet to disable tamper switches for all open doors. Use adhesive tape...
Remark
Published
06/02/2023 1:18 PM
8561 - 7291 - Disable both infrared occupancy sensors; Remark:8514
Procedure Step
Published
09/18/2023 12:05 AM
5291 - Note : It is good practice to verify all cables and connectors are labeled prior to ...
Annotation
Published
10/24/2022 8:35 AM
7291 - Disable both infrared occupancy sensors
Instruction
Published
05/01/2023 8:15 AM
8514 - Verify sensors mounted in control pillar door are receivers.
Remark
Published
09/29/2023 11:52 AM
9205 - To disconnect sensor cable, turn collar counterclockwise and pull away from s...
Remark
Published
09/29/2023 11:52 AM
8221 - 7676 - Brief system operators on expected work, duration, anticipated alarms, and fa...; Remark:
Procedure Step
Published
09/01/2023 9:26 PM
7676 - Brief system operators on expected work, duration, anticipated alarms, and fa...
Instruction
Published
07/01/2023 11:39 PM
8890 - 7292 - Uninstall Faulty Nano Controller; Remark:
Procedure Step
Published
09/25/2023 7:30 PM
7292 - Uninstall Faulty Nano Controller
Instruction
Published
05/01/2023 8:18 AM
8370 - 8369 - Disconnect RJ-45 Ethernet cable; Remark:8368
Procedure Step
Published
09/25/2023 7:21 PM
8369 - Disconnect RJ-45 Ethernet cable
Instruction
Published
09/12/2023 10:46 AM
8368 -
Remark
Published
09/12/2023 10:46 AM
8377 - 8376 - Disconnect occupancy sensor wires; Remark:8375
Procedure Step
Published
09/25/2023 7:23 PM
8376 - Disconnect occupancy sensor wires
Instruction
Published
09/12/2023 10:57 AM
8375 - Use small slotted screwdriver. Remove wires from I1 terminal...
Remark
Published
09/12/2023 11:01 AM
8378 - 8374 - Disconnect power wires; Remark:8373
Procedure Step
Published
09/25/2023 7:24 PM
8374 - Disconnect power wires
Instruction
Published
09/12/2023 11:01 AM
8373 - These wires go to Terminal Block 1 (TB1). Use small slotted screwdriver
Remark
Published
09/12/2023 11:03 AM
8379 - 8372 - Disconnect occupancy output wire; Remark:8371
Procedure Step
Published
09/25/2023 7:26 PM
8372 - Disconnect occupancy output wire
Instruction
Published
09/12/2023 11:03 AM
8371 - Use small slotted screwdriver. Remove green wire from Q1 ter...
Remark
Published
09/12/2023 11:04 AM
8891 - 7297 - Remove faulty Nano Controller; Remark:8380
Procedure Step
Published
09/25/2023 7:31 PM
8382 - Note : Nano Controller installation may differ from configuration shown in this proc...
Annotation
Published
09/12/2023 11:16 AM
7297 - Remove faulty Nano Controller
Instruction
Published
05/01/2023 8:21 AM
8380 - Use slotted screwdriver to pull down tab and rotate Nano Controller up. Use m...
Remark
Published
09/12/2023 11:15 AM
3397 - 3395 - Label faulty component; Remark:3396
Procedure Step
Published
07/21/2024 6:59 AM
3395 - Label faulty component
Instruction
Published
08/07/2021 11:07 AM
3396 - Use tag or tape. Include date of removal, description of failure symptoms, co...
Remark
Published
08/09/2021 11:35 AM
8894 - 7298 - Install New Nano Controller; Remark:
Procedure Step
Published
09/25/2023 8:01 PM
7298 - Install New Nano Controller
Instruction
Published
05/01/2023 8:24 AM
8895 - 7299 - Mount new Nano Controller; Remark:8892
Procedure Step
Published
09/25/2023 8:02 PM
7299 - Mount new Nano Controller
Instruction
Published
05/01/2023 8:24 AM
8892 - Hook nano controller to top of mounting rail and rotate down. Nano controller...
Remark
Published
09/25/2023 7:37 PM
8896 - 7300 - Reconnect occupancy output wire; Remark:7338
Procedure Step
Published
09/25/2023 9:37 PM
7263 - Caution : Correct placement of connectors and wiring is critical to proper operation.
Annotation
Published
04/24/2023 2:32 PM
7300 - Reconnect occupancy output wire
Instruction
Published
05/01/2023 8:26 AM
7338 - Insert green wire in Q1 terminal. Use a small slotted screwdriver.
Remark
Published
05/03/2023 10:48 AM
8897 - 7301 - Reconnect power wires; Remark:7339
Procedure Step
Published
09/25/2023 8:04 PM
7301 - Reconnect power wires
Instruction
Published
05/01/2023 8:26 AM
7339 - Use a small slotted screwdriver to reconnect existing power wires on terminal...
Remark
Published
09/25/2023 7:48 PM
8898 - 7302 - Reconnect occupancy sensor wires; Remark:7340
Procedure Step
Published
09/25/2023 8:05 PM
7302 - Reconnect occupancy sensor wires
Instruction
Published
05/01/2023 8:27 AM
7340 - Connect black wire from black infrared occupancy sensor to I1
Remark
Published
09/25/2023 7:53 PM
8899 - 7303 - Reconnect RJ-45 Ethernet cable; Remark:8893
Procedure Step
Published
09/25/2023 8:06 PM
7303 - Reconnect RJ-45 Ethernet cable
Instruction
Published
05/01/2023 8:28 AM
8893 - Nano Controller RJ45 Connection
Remark
Published
09/25/2023 7:57 PM
7279 - 7249 - Return equipment to normal operating condition; Remark:
Procedure Step
Published
04/27/2023 4:13 PM
7249 - Return equipment to normal operating condition
Instruction
Published
04/08/2025 3:22 PM
7280 - 7250 - Power on RPM; Remark:7251
Procedure Step
Published
04/27/2023 4:14 PM
7250 - Power on RPM
Instruction
Published
05/01/2023 8:31 AM
7251 - Move LD-260 switch to ON position. The LED PWR ON
Remark
Published
05/10/2023 3:14 PM
7281 - 7252 - Verify RPM start-up; Remark:7253
Procedure Step
Published
04/20/2025 3:26 PM
7252 - Verify RPM start-up
Instruction
Published
04/27/2023 2:23 PM
7253 - RPM will perform a power on self-test (POST) and collect a background radiati...
Remark
Published
05/10/2023 3:14 PM
8506 - 7254 - Confirm network connection; Remark:7255
Procedure Step
Published
09/24/2023 3:34 PM
7254 - Confirm network connection
Instruction
Published
04/27/2023 2:22 PM
7255 - Contact operators to confirm communications have been reestablished between RPM ...
Remark
Published
05/10/2023 3:15 PM
8588 - 7305 - Enable both infrared occupancy sensors; Remark:8559
Procedure Step
Published
09/17/2023 11:04 PM
5553 - Caution : Correct placement of connectors and wiring is critical to proper operation.
Annotation
Published
10/28/2022 2:19 PM
7305 - Enable both infrared occupancy sensors
Instruction
Published
05/01/2023 8:33 AM
8559 - To reconnect sensor cable, align connectors, push towards sensor, and turn co...
Remark
Published
09/29/2023 12:05 PM
8433 - 8432 - Close all RPM doors; Remark:
Procedure Step
Published
09/14/2023 9:14 AM
8432 - Close all RPM doors
Instruction
Published
09/14/2023 9:14 AM
8434 - 8431 - Generate speed message; Remark:8430
Procedure Step
Published
09/14/2023 9:15 AM
8431 - Generate speed message
Instruction
Published
09/14/2023 9:14 AM
8430 - Stand to side of control pillar. Open door with infrared sensors.
Remark
Published
09/14/2023 9:15 AM
8606 - 7308 - Verify Nano Controller response; Remark:8599
Procedure Step
Published
09/18/2023 12:49 PM
7308 - Verify Nano Controller response
Instruction
Published
05/01/2023 8:35 AM
8599 - Nano Controller LEDs will illuminate (IN1, IN2
Remark
Published
09/18/2023 12:36 PM
8437 - 8425 - Verify speed message in CAS; Remark:8424
Procedure Step
Published
09/14/2023 9:37 AM
8425 - Verify speed message in CAS
Instruction
Published
09/14/2023 9:36 AM
8424 - Contact CAS operator to verify “SP” appears in RAVEN [Radiation Alarm and...
Remark
Published
09/14/2023 9:37 AM
8589 - 7310 - Enable tamper switches; Remark:7348
Procedure Step
Published
09/17/2023 11:07 PM
7310 - Enable tamper switches
Instruction
Published
05/01/2023 8:36 AM
7348 - Remove all magnets and/or adhesive tape from door switches.
Remark
Published
09/17/2023 10:23 PM
8507 - 7256 - Close and lock all RPM doors; Remark:
Procedure Step
Published
09/24/2023 3:35 PM
7256 - Close and lock all RPM doors
Instruction
Published
04/27/2023 2:21 PM
7842 - 7820 - Inform system operators upon completion of maintenance action; Remark:
Procedure Step
Published
07/07/2023 11:15 PM
7820 - Inform system operators upon completion of maintenance action
Instruction
Published
07/07/2023 10:02 PM
322 - 321 - Document maintenance actions; Remark:
Procedure Step
Published
06/17/2021 9:49 AM
321 - Document maintenance actions
Instruction
Published
04/21/2025 11:19 AM
2869 - 2585 - Document maintenance performed; Remark:2866
Procedure Step
Published
06/18/2021 5:58 PM
2585 - Document maintenance performed
Instruction
Published
07/09/2021 12:15 PM
2866 - Record observations, times, and results for the maintenance report.
Remark
Published
04/21/2025 11:39 AM
4706 - 4705 - Submit report; Remark:4864
Procedure Step
Published
06/29/2022 9:50 AM
4705 - Submit report
Instruction
Published
06/29/2022 9:50 AM
4864 - As specified by management or contractual obligations.
Remark
Published
07/28/2022 1:36 PM
Corrective Maintenance Procedure
Document Type
Published
03/02/2020 3:32 PM
Upon failure of Nano Controller
Frequency
Published
09/25/2023 8:49 PM
Warning
Annotation Type
Published
03/02/2020 3:25 PM
Note
Annotation Type
Published
03/02/2020 3:25 PM
Caution
Annotation Type
Published
03/02/2020 3:24 PM
Technician 2
Skill Level
Published
04/09/2020 1:17 AM
Keys to access RPM
Replacement Parts
Published
04/27/2023 6:56 PM
Magnets and adhesive tape to disable door tamper switches
Replacement Parts
Published
06/02/2023 10:08 PM
Medium Phillips (PH2) screwdriver
Tools
Published
04/24/2020 4:40 PM
Small slotted (flathead) screwdriver
Tools
Published
09/11/2020 11:23 AM
Orange/yellow safety vest
Replacement Parts
Published
04/27/2023 6:56 PM
Safety shoes
Replacement Parts
Published
04/27/2023 6:56 PM
Gloves
Replacement Parts
Published
05/10/2023 3:28 PM
Protective headwear: glasses, hard hat
Replacement Parts
Published
05/10/2023 3:31 PM
Orange traffic cones
Replacement Parts
Published
04/27/2023 6:56 PM
Disable tamper switch
Image
Published
09/07/2023 8:22 PM
Disable Tamper Switch
Image
Published
06/02/2023 2:28 PM
Infrared Receiver
Image
Published
09/17/2023 7:09 PM
Infrared Receiver DC
Image
Published
09/29/2023 11:47 AM
Infrared Disconnect Sensor Cable
Image
Published
09/17/2023 7:11 PM
Infrared Sensor Disconnect
Image
Published
09/17/2023 7:12 PM
nanocontroller - Disconnect RJ-45 Ethernet cable
Image
Published
09/12/2023 10:40 AM
Disconnect occupancy sensor wires
Image
Published
09/12/2023 10:50 AM
Disconnect power wires
Image
Published
09/12/2023 10:52 AM
Disconnect occupancy output wire
Image
Published
09/12/2023 10:55 AM
Remove Nano Controller
Image
Published
09/12/2023 11:07 AM
Remove Nano Controller 2
Image
Published
09/12/2023 11:08 AM
Install Nano Controller
Image
Published
09/25/2023 7:36 PM
Nano Controller Output Wire
Image
Published
09/25/2023 9:33 PM
Power to Nano Controller
Image
Published
09/25/2023 7:47 PM
Connect Occupancy Sensor Wires
Image
Published
09/25/2023 7:53 PM
Connect RJ45 in Nano Controller
Image
Published
09/25/2023 7:56 PM
LD-260 Disconnect Switch Power On
Image
Published
05/04/2023 3:37 PM
Infrared Connection
Image
Published
09/29/2023 12:02 PM
Infrared Cable Installation
Image
Published
09/17/2023 10:12 PM
Infrared Sensor Cable
Image
Published
09/17/2023 10:13 PM
Open door with infrared sensors
Image
Published
09/14/2023 9:01 AM
PLC Response
Image
Published
09/18/2023 12:35 PM
Remove all magnets and or adhesive tape from door switches
Image
Published
09/08/2023 4:18 PM
Remove Magnet on Tamper Switch
Image
Published
06/02/2023 4:31 PM

RPM SPY-2 to IXIO-DT1 Occupancy Sensor Conversion

Last Updated: 04/26/2025 1:43 AM

The following table lists all the components that make up the document.

Title Type Status Last Updated
Rapiscan PM-700 Pedestrian Monitor
Device
Published
06/20/2024 11:38 AM
1402 - 7927 - Establish Initial Conditions; Remark:
Procedure Step
Published
09/30/2022 1:47 PM
7927 - Establish Initial Conditions
Instruction
Published
07/12/2023 12:23 AM
8972 - 7231 - Close lane; Remark:7415
Procedure Step
Published
09/25/2023 10:51 PM
7231 - Close lane
Instruction
Published
04/18/2023 1:00 PM
7415 - Re-route pedestrian traffic.
Remark
Published
06/02/2023 1:08 PM
7269 - 7232 - Open RPM door; Remark:7234
Procedure Step
Published
04/27/2023 7:02 PM
7232 - Open RPM door
Instruction
Published
04/18/2023 1:02 PM
7234 - Open all doors needed to access components.
Remark
Published
04/19/2025 7:48 PM
7454 - 7290 - Disable tamper switches; Remark:7416
Procedure Step
Published
06/02/2023 5:25 PM
7290 - Disable tamper switches
Instruction
Published
05/01/2023 8:14 AM
7416 - Use a magnet to disable tamper switches for all open doors. Use adhesive tape...
Remark
Published
06/02/2023 1:18 PM
7270 - 7235 - Power off RPM; Remark:7236
Procedure Step
Published
09/01/2023 7:57 PM
7235 - Power off RPM
Instruction
Published
04/24/2023 12:30 PM
7236 - Move LD-260 switch to OFF position. The PWR ON
Remark
Published
04/27/2023 4:25 PM
7479 - 7417 - Prepare New Occupancy Sensor; Remark:
Procedure Step
Published
06/02/2023 6:13 PM
7417 - Prepare New Occupancy Sensor
Instruction
Published
06/02/2023 1:39 PM
7456 - 7418 - Remove cover from new occupancy sensor; Remark:7419
Procedure Step
Published
06/02/2023 5:27 PM
7418 - Remove cover from new occupancy sensor
Instruction
Published
06/02/2023 1:43 PM
7419 - Use a slotted screwdriver to pry the cover off from the side.
Remark
Published
04/13/2025 5:44 PM
7457 - 7420 - Verify narrow field radar antenna is installed; Remark:7421
Procedure Step
Published
04/13/2025 6:18 PM
7420 - Verify narrow field radar antenna is installed
Instruction
Published
04/13/2025 5:44 PM
7421 - The IXIO-DT1 should come with the narrow field antenna installed.
Remark
Published
06/02/2023 2:14 PM
8901 - If needed, the antenna can be changed. Remove cover. Install narrow field ant...
Remark
Published
09/25/2023 9:51 PM
8889 - 8888 - Prepare Mounting Holes; Remark:
Procedure Step
Published
09/25/2023 4:55 PM
8888 - Prepare Mounting Holes
Instruction
Published
09/25/2023 4:54 PM
8884 - 8883 - Mark mounting hole height; Remark:8882
Procedure Step
Published
09/25/2023 4:58 PM
8883 - Mark mounting hole height
Instruction
Published
09/25/2023 4:56 PM
8882 - Use erasable marker or pencil to draw a level horizontal line. Mounting hole ...
Remark
Published
09/25/2023 4:58 PM
8886 - 8879 - Mark centerline of pedestrian monitor door; Remark:8878
Procedure Step
Published
09/25/2023 5:01 PM
8879 - Mark centerline of pedestrian monitor door
Instruction
Published
09/25/2023 5:00 PM
8878 - Use erasable marker or pencil to draw a vertical line.
Remark
Published
09/25/2023 5:01 PM
8885 - 8881 - Attach mounting template; Remark:8880
Procedure Step
Published
09/25/2023 4:59 PM
8881 - Attach mounting template
Instruction
Published
09/25/2023 4:58 PM
8880 - Template provided with the IXIO-DT1 has a self-adhesive backing. Template may...
Remark
Published
09/25/2023 4:59 PM
8887 - 8877 - Mark location of 3.2-mm (1/8-inch) mounting holes; Remark:8876
Procedure Step
Published
09/25/2023 5:03 PM
8904 - Caution : Ensure placement of mounting holes will not interfere with internal wiring in...
Annotation
Published
09/25/2023 9:57 PM
8877 - Mark location of 3.2-mm (1/8-inch) mounting holes
Instruction
Published
09/25/2023 5:01 PM
8876 - If available, use a center punch and hammer to create a dimple at each mounti...
Remark
Published
09/25/2023 5:01 PM
8905 - 8903 - Mark location of 8-mm (5/16-inch) hole for wire passage; Remark:8902
Procedure Step
Published
09/25/2023 9:58 PM
8903 - Mark location of 8-mm (5/16-inch) hole for wire passage
Instruction
Published
09/25/2023 9:58 PM
8902 - If available, use a center punch and hammer to create a dimple at center of w...
Remark
Published
09/25/2023 9:58 PM
8946 - 8945 - Drill Installation Holes; Remark:
Procedure Step
Published
09/25/2023 10:01 PM
8945 - Drill Installation Holes
Instruction
Published
09/25/2023 10:01 PM
8939 - 8938 - Hold or block the door in an open position; Remark:
Procedure Step
Published
09/25/2023 10:01 PM
8938 - Hold or block the door in an open position
Instruction
Published
09/25/2023 10:01 PM
8940 - 8935 - Drill two (2) mounting holes; Remark:8934
Procedure Step
Published
09/25/2023 10:02 PM
8936 - Warning : Wear protective gloves and eyewear when drilling into cabinet door.
Annotation
Published
09/25/2023 10:05 PM
8937 - Caution : Do not damage interior of RPM when drilling holes.
Annotation
Published
09/25/2023 10:05 PM
8935 - Drill two (2) mounting holes
Instruction
Published
09/25/2023 10:02 PM
8934 - Use a 3.2-mm (1/8-inch) drill bit.
Remark
Published
09/25/2023 10:02 PM
8941 - 8933 - Drill wire passage hole; Remark:8932
Procedure Step
Published
09/25/2023 10:03 PM
8933 - Drill wire passage hole
Instruction
Published
09/25/2023 10:03 PM
8932 - Use an 8-mm (5/16-inch) drill bit.
Remark
Published
09/25/2023 10:03 PM
8942 - 8931 - Clean newly drilled holes; Remark:8930
Procedure Step
Published
09/25/2023 10:04 PM
8931 - Clean newly drilled holes
Instruction
Published
09/25/2023 10:04 PM
8930 - Use the deburring tool
Remark
Published
09/25/2023 10:04 PM
8943 - 8929 - Partially insert two (2) screws into mounting holes; Remark:8928
Procedure Step
Published
09/25/2023 10:06 PM
8929 - Partially insert two (2) screws into mounting holes
Instruction
Published
09/25/2023 10:06 PM
8928 - Mounting screws are included in the IXIO-DT-1 kit. Do not fully tighten screw...
Remark
Published
09/25/2023 10:06 PM
8944 - 8926 - Insert rubber grommet in wire passage hole; Remark:8925
Procedure Step
Published
09/25/2023 10:08 PM
8927 - Note : Protecting wires with a rubber grommet is critical to preventing damage to wi...
Annotation
Published
09/25/2023 10:08 PM
8926 - Insert rubber grommet in wire passage hole
Instruction
Published
09/25/2023 10:07 PM
8925 - rubber grommet
Remark
Published
09/25/2023 10:08 PM
8924 - 8923 - Install IXIO-DT1 Sensor; Remark:
Procedure Step
Published
09/25/2023 10:09 PM
8923 - Install IXIO-DT1 Sensor
Instruction
Published
09/25/2023 10:09 PM
8918 - 8917 - Feed wiring connector through grommet; Remark:8915
Procedure Step
Published
09/25/2023 10:13 PM
8917 - Feed wiring connector through grommet
Instruction
Published
09/25/2023 10:11 PM
8915 - The wiring assembly is included in the IXIO-DT1 kit. Feed loose end of wiring...
Remark
Published
09/25/2023 10:11 PM
8916 - Leave approximately 15 cm (6 in) of wire remaining outside of cabinet.
Remark
Published
09/25/2023 10:13 PM
8919 - 8914 - Mount new sensor; Remark:8912
Procedure Step
Published
09/25/2023 10:15 PM
8914 - Mount new sensor
Instruction
Published
09/25/2023 10:13 PM
8912 - First, slide left side onto mounting screw.
Remark
Published
09/25/2023 10:14 PM
8913 - Then, place right side over mounting screw and push down.
Remark
Published
09/25/2023 10:15 PM
8920 - 8911 - Tighten two (2) mounting screws; Remark:8910
Procedure Step
Published
09/25/2023 10:16 PM
8911 - Tighten two (2) mounting screws
Instruction
Published
09/25/2023 10:15 PM
8910 - Use medium Phillips (PH2) screwdriver. Take care not to overtighten.
Remark
Published
09/25/2023 10:16 PM
8921 - 8909 - Route wiring through clamp and connect; Remark:8908
Procedure Step
Published
09/25/2023 10:18 PM
8909 - Route wiring through clamp and connect
Instruction
Published
09/25/2023 10:16 PM
8908 - route wiring through clamp and connect
Remark
Published
09/25/2023 10:18 PM
8922 - 8907 - Adjust angle of the radar antenna; Remark:8906
Procedure Step
Published
09/25/2023 10:20 PM
8907 - Adjust angle of the radar antenna
Instruction
Published
09/25/2023 10:18 PM
8906 - The angle is adjusted by manually rotating the antenna up or down. The defaul...
Remark
Published
09/25/2023 10:20 PM
8970 - 8969 - Connect Wiring to RPM; Remark:
Procedure Step
Published
09/25/2023 10:23 PM
8969 - Connect Wiring to RPM
Instruction
Published
09/25/2023 10:22 PM
8963 - 8962 - Disconnect existing SPY-2 wiring; Remark:8961
Procedure Step
Published
09/25/2023 10:25 PM
7351 - Note : It is good practice to verify all cables and connectors are labeled prior to ...
Annotation
Published
05/03/2023 11:25 AM
8962 - Disconnect existing SPY-2 wiring
Instruction
Published
09/25/2023 10:24 PM
8961 - Do not remove existing occupancy sensor from door panel. Disconnect SPY-2 wir...
Remark
Published
09/25/2023 10:24 PM
8964 - 8960 - Route new cable to TB2; Remark:8959
Procedure Step
Published
09/25/2023 10:26 PM
8960 - Route new cable to TB2
Instruction
Published
09/25/2023 10:25 PM
8959 - New IXIO-DT1 cable should be routed along existing SPY-2 cable. Cable ties ma...
Remark
Published
09/25/2023 10:26 PM
8965 - 8958 - Connect red wire to TB2, Pin 16; Remark:8956
Procedure Step
Published
09/25/2023 10:30 PM
7263 - Caution : Correct placement of connectors and wiring is critical to proper operation.
Annotation
Published
04/24/2023 2:32 PM
8958 - Connect red wire to TB2, Pin 16
Instruction
Published
09/25/2023 10:27 PM
8956 - Red is power (+12 VDC) wire.
Remark
Published
09/25/2023 10:29 PM
8957 - For models with older terminal blocks, it may be necessary to use a fork conn...
Remark
Published
09/25/2023 10:30 PM
8966 - 8955 - Connect both black and white wires to TB2, Pin 15; Remark:8954
Procedure Step
Published
09/25/2023 10:32 PM
8955 - Connect both black and white wires to TB2, Pin 15
Instruction
Published
09/25/2023 10:31 PM
8954 - Black is the ground wire. White is the common wire
Remark
Published
09/25/2023 10:32 PM
8967 - 8953 - Connect green wire to TB2, Pin 6; Remark:8952
Procedure Step
Published
09/25/2023 10:34 PM
8953 - Connect green wire to TB2, Pin 6
Instruction
Published
09/25/2023 10:33 PM
8952 - Green is the occupancy signal to the SCA-775 module.
Remark
Published
09/25/2023 10:34 PM
8968 - 8951 - Apply sealant if needed; Remark:8950
Procedure Step
Published
09/25/2023 10:35 PM
8951 - Apply sealant if needed
Instruction
Published
09/25/2023 10:34 PM
8950 - Access wire penetration hole from back of the RPM door.
Remark
Published
09/25/2023 10:35 PM
7279 - 7249 - Return equipment to normal operating condition; Remark:
Procedure Step
Published
04/27/2023 4:13 PM
7249 - Return equipment to normal operating condition
Instruction
Published
04/08/2025 3:22 PM
8949 - 8948 - Hold door open; Remark:8947
Procedure Step
Published
09/25/2023 10:37 PM
8948 - Hold door open
Instruction
Published
09/25/2023 10:37 PM
8947 - Do not move door. Door must remain stationary to prevent occupancy.
Remark
Published
09/25/2023 10:37 PM
7280 - 7250 - Power on RPM; Remark:7251
Procedure Step
Published
04/27/2023 4:14 PM
7250 - Power on RPM
Instruction
Published
05/01/2023 8:31 AM
7251 - Move LD-260 switch to ON position. The LED PWR ON
Remark
Published
05/10/2023 3:14 PM
7468 - 7304 - Confirm RPM has restarted correctly; Remark:7487
Procedure Step
Published
06/02/2023 5:36 PM
7304 - Confirm RPM has restarted correctly
Instruction
Published
05/01/2023 8:31 AM
7487 - The SC-770 controller will display "OK" following Power On Self-Test (POST) a...
Remark
Published
06/02/2023 10:35 PM
7389 - 7254 - Confirm network connection; Remark:7255
Procedure Step
Published
05/04/2023 4:33 PM
7254 - Confirm network connection
Instruction
Published
04/27/2023 2:22 PM
7255 - Contact operators to confirm communications have been reestablished between RPM ...
Remark
Published
05/10/2023 3:15 PM
7470 - 7442 - Generate occupancy; Remark:7443
Procedure Step
Published
06/02/2023 5:37 PM
7442 - Generate occupancy
Instruction
Published
06/02/2023 4:19 PM
7443 - Create motion in front of occupancy sensor. While holding the door open and s...
Remark
Published
06/02/2023 4:21 PM
7471 - 7444 - Verify occupancy sensor functionality; Remark:7445
Procedure Step
Published
06/02/2023 5:38 PM
7444 - Verify occupancy sensor functionality
Instruction
Published
06/02/2023 4:32 PM
7445 - IXIO-DT1 green sensor light will illuminate.
Remark
Published
06/02/2023 4:35 PM
8973 - Left latch on the LCD screen will indicate a “closed” circuit.
Remark
Published
09/25/2023 11:05 PM
8974 - SC-770 status will read “OCCUPIED”.
Remark
Published
09/25/2023 11:06 PM
7472 - 7446 - Install sensor cover; Remark:7447
Procedure Step
Published
06/02/2023 5:38 PM
7446 - Install sensor cover
Instruction
Published
06/02/2023 4:37 PM
7447 - The cover should snap into place.
Remark
Published
06/02/2023 4:38 PM
7473 - 7448 - If needed, apply sealant; Remark:7449
Procedure Step
Published
06/02/2023 5:39 PM
7448 - If needed, apply sealant
Instruction
Published
06/02/2023 4:39 PM
7449 - If used outdoors, sealant should be applied to top and sides of cover. Do not...
Remark
Published
06/02/2023 4:41 PM
7474 - 7310 - Enable tamper switches; Remark:7451
Procedure Step
Published
06/02/2023 5:41 PM
7310 - Enable tamper switches
Instruction
Published
05/01/2023 8:36 AM
7451 - Remove magnets and/or adhesive tape from door tamper switches.
Remark
Published
04/13/2025 5:46 PM
7283 - 7256 - Close and lock all RPM doors; Remark:
Procedure Step
Published
09/01/2023 11:45 PM
7256 - Close and lock all RPM doors
Instruction
Published
04/27/2023 2:21 PM
7842 - 7820 - Inform system operators upon completion of maintenance action; Remark:
Procedure Step
Published
07/07/2023 11:15 PM
7820 - Inform system operators upon completion of maintenance action
Instruction
Published
07/07/2023 10:02 PM
322 - 321 - Document maintenance actions; Remark:
Procedure Step
Published
06/17/2021 9:49 AM
321 - Document maintenance actions
Instruction
Published
04/21/2025 11:19 AM
2869 - 2585 - Document maintenance performed; Remark:2866
Procedure Step
Published
06/18/2021 5:58 PM
2585 - Document maintenance performed
Instruction
Published
07/09/2021 12:15 PM
2866 - Record observations, times, and results for the maintenance report.
Remark
Published
04/21/2025 11:39 AM
4706 - 4705 - Submit report; Remark:4864
Procedure Step
Published
06/29/2022 9:50 AM
4705 - Submit report
Instruction
Published
06/29/2022 9:50 AM
4864 - As specified by management or contractual obligations.
Remark
Published
07/28/2022 1:36 PM
Corrective Maintenance Procedure
Document Type
Published
03/02/2020 3:32 PM
minutes
Duration
Published
05/26/2022 11:41 AM
Upon failure of the Visonic SPY-2 infrared curtain occupancy sensor
Frequency
Published
09/25/2023 3:49 PM
Caution
Annotation Type
Published
03/02/2020 3:24 PM
Warning
Annotation Type
Published
03/02/2020 3:25 PM
Note
Annotation Type
Published
03/02/2020 3:25 PM
Technician 2
Skill Level
Published
04/09/2020 1:17 AM
Keys to access RPM
Replacement Parts
Published
04/27/2023 6:56 PM
Magnets and adhesive tape to disable door tamper switches
Replacement Parts
Published
06/02/2023 10:08 PM
Medium Phillips (PH2) screwdriver
Tools
Published
04/24/2020 4:40 PM
Cordless drill
Tools
Published
09/25/2023 4:19 PM
3.2-mm (1/8-inch) drill bit (for metal)
Tools
Published
09/25/2023 4:19 PM
8-mm (5/16-inch) drill bit (for metal)
Tools
Published
09/25/2023 4:19 PM
Deburring tool
Tools
Published
09/25/2023 4:20 PM
safety glasses
Replacement Parts
Published
07/02/2023 4:48 PM
Gloves (heavy duty)
Tools
Published
09/25/2023 4:20 PM
Wire stripper
Tools
Published
09/25/2023 4:20 PM
Wire crimping tool
Tools
Published
09/25/2023 4:20 PM
Orange/yellow safety vest
Replacement Parts
Published
04/27/2023 6:56 PM
Safety shoes
Replacement Parts
Published
04/27/2023 6:56 PM
Protective headwear: glasses, hard hat
Replacement Parts
Published
05/10/2023 3:31 PM
Orange traffic cones
Replacement Parts
Published
04/27/2023 6:56 PM
Disable tamper switch
Image
Published
09/07/2023 8:22 PM
Disable Tamper Switch
Image
Published
06/02/2023 2:28 PM
LD-260 Disconnect Switch Power Off
Image
Published
04/24/2023 12:49 PM
Remove Occupancy Sensor Cover
Image
Published
06/02/2023 2:38 PM
The IXIO-DT1 should come with the narrow field antenna installed
Image
Published
09/25/2023 8:35 PM
Verify narrow field radar antenna is installed
Image
Published
09/25/2023 8:38 PM
Verify narrow field radar antenna is installed 2
Image
Published
09/25/2023 8:39 PM
Mark mounting hole height
Image
Published
09/25/2023 8:40 PM
Mark centerline of pedestrian monitor door
Image
Published
09/25/2023 8:42 PM
Attach mounting template
Image
Published
09/25/2023 8:44 PM
Mark location of 3.2-mm (1/8-inch) mounting holes
Image
Published
09/25/2023 8:46 PM
Mark location of 8-mm (5/16-inch) hole for wire passage
Image
Published
09/25/2023 8:47 PM
Insert rubber grommet in wire passage hole
Image
Published
09/25/2023 8:48 PM
Feed wiring connector through grommet
Image
Published
09/25/2023 8:50 PM
Feed wiring connector through grommet2
Image
Published
09/25/2023 8:51 PM
Mount new sensor
Image
Published
09/25/2023 8:52 PM
Mount new sensor2
Image
Published
09/25/2023 8:53 PM
Tighten two (2) mounting screws
Image
Published
09/25/2023 8:54 PM
Route wiring through clamp and connect
Image
Published
09/25/2023 8:55 PM
Adjust angle of the radar antenna
Image
Published
09/25/2023 8:56 PM
Adjust angle of the radar antenna2
Image
Published
09/25/2023 8:58 PM
Disconnect existing SPY-2 wiring
Image
Published
09/25/2023 8:59 PM
Route new cable to TB2
Image
Published
09/25/2023 9:01 PM
Connect red wire to TB2, Pin 16
Image
Published
09/25/2023 9:02 PM
Connect red wire to TB2, Pin 16 (2)
Image
Published
09/25/2023 9:03 PM
fork connector
Image
Published
09/25/2023 9:04 PM
Connect both black and white wires to TB2, Pin 15
Image
Published
09/25/2023 9:06 PM
Connect green wire to TB2, Pin 6
Image
Published
09/25/2023 9:34 PM
Apply sealant if needed
Image
Published
09/25/2023 9:36 PM
LD-260 Disconnect Switch Power On
Image
Published
05/04/2023 3:37 PM
IXIO-DT1 green sensor light will illuminate
Image
Published
09/25/2023 9:37 PM
Verify occupancy sensor functionality
Image
Published
09/25/2023 9:38 PM
Verify occupancy sensor functionality2
Image
Published
09/25/2023 9:39 PM
Install Occupancy Sensor Cover
Image
Published
06/02/2023 4:26 PM
Occupancy Sensor Sealant Application
Image
Published
06/02/2023 4:30 PM
Remove Magnet from Tamper.PNG
Image
Published
09/28/2023 9:37 AM
Remove Magnet on Tamper Switch
Image
Published
06/02/2023 4:31 PM

PackEye Reseat FHT 681 Connections

Last Updated: 04/26/2025 1:41 AM

The following table lists all the components that make up the document.

Title Type Status Last Updated
Thermo FHT1377 PackEye
Device
Published
10/28/2024 3:37 PM
6202 - 6201 - Uninstall FHT 681 Amplifier; Remark:
Procedure Step
Published
11/21/2022 8:55 AM
6201 - Uninstall FHT 681 Amplifier
Instruction
Published
11/21/2022 8:55 AM
6198 - 313 - Power off instrument; Remark:5939
Procedure Step
Published
04/07/2025 4:34 PM
313 - Power off instrument
Instruction
Published
07/23/2021 2:41 PM
5939 - Press and hold the power button for approximately 10 seconds until indicator ...
Remark
Published
11/07/2022 2:33 PM
6199 - 4222 - Place instrument on flat surface; Remark:4221
Procedure Step
Published
11/21/2022 8:59 AM
4222 - Place instrument on flat surface
Instruction
Published
05/10/2022 1:54 PM
4221 - Shoulder straps should be facing down.
Remark
Published
05/10/2022 1:55 PM
6200 - 3876 - Open top of backpack; Remark:5665
Procedure Step
Published
11/21/2022 9:06 AM
3876 - Open top of backpack
Instruction
Published
04/04/2022 3:14 PM
5665 - IO PackEye Open Top for Battery
Remark
Published
11/09/2024 8:06 PM
6217 - 6216 - Disconnect straps on sides of backpack; Remark:6215
Procedure Step
Published
11/28/2022 9:50 AM
6216 - Disconnect straps on sides of backpack
Instruction
Published
11/28/2022 9:46 AM
6215 -
Remark
Published
11/28/2022 9:50 AM
6224 - 6223 - Partially remove backpack contents; Remark:6222
Procedure Step
Published
11/28/2022 9:57 AM
6223 - Partially remove backpack contents
Instruction
Published
11/28/2022 9:52 AM
6222 - Slowly slide foam assembly out of backpack to access FHT 681 amplifier. This ...
Remark
Published
11/28/2022 9:57 AM
6225 - 6221 - Disconnect gamma detector; Remark:6220
Procedure Step
Published
11/28/2022 10:03 AM
6221 - Disconnect gamma detector
Instruction
Published
11/28/2022 9:59 AM
6220 - The gamma detector is connected to the FHT 681 amplifier at PMT1
Remark
Published
11/28/2022 10:03 AM
6226 - 6219 - Disconnect RS-232 jumper and distribution box connections; Remark:5670
Procedure Step
Published
11/28/2022 10:07 AM
6219 - Disconnect RS-232 jumper and distribution box connections
Instruction
Published
11/28/2022 10:04 AM
5670 - Use small, slotted screwdriver.
Remark
Published
11/03/2022 9:07 AM
6218 -
Remark
Published
11/28/2022 10:06 AM
6231 - 6229 - Rotate power supply and FHT 681 modules; Remark:6227
Procedure Step
Published
11/28/2022 10:13 AM
6230 - Caution : Do not completely remove FHT 681 module as neutron detectors are still connec...
Annotation
Published
11/28/2022 10:13 AM
6229 - Rotate power supply and FHT 681 modules
Instruction
Published
11/28/2022 10:09 AM
6227 - The neutron detector connections will be accessible.
Remark
Published
11/28/2022 10:10 AM
6228 -
Remark
Published
11/28/2022 10:12 AM
6235 - 6234 - Disconnect two (2) neutron detectors; Remark:6232
Procedure Step
Published
11/28/2022 10:18 AM
6234 - Disconnect two (2) neutron detectors
Instruction
Published
11/28/2022 10:15 AM
6232 - There are two (2) neutron detectors. Unscrew collar counterclockwise. Pull co...
Remark
Published
11/28/2022 10:17 AM
6233 -
Remark
Published
11/28/2022 10:18 AM
6240 - 6238 - Separate FHT 681 amplifier from power supply module; Remark:6236
Procedure Step
Published
11/28/2022 10:24 AM
6239 - Note : The hook and loop strips may require significant force to separate.
Annotation
Published
11/28/2022 10:24 AM
6238 - Separate FHT 681 amplifier from power supply module
Instruction
Published
11/28/2022 10:20 AM
6236 - There are two (2) hook and loop (Velcro) strips attaching the power supply mo...
Remark
Published
11/28/2022 10:22 AM
6237 -
Remark
Published
11/28/2022 10:23 AM
6249 - 6248 - Disassemble FHT 681 Amplifier; Remark:
Procedure Step
Published
11/28/2022 1:15 PM
6248 - Disassemble FHT 681 Amplifier
Instruction
Published
11/28/2022 1:15 PM
6246 - 6245 - Remove four (4) corner screws; Remark:5296
Procedure Step
Published
11/28/2022 1:19 PM
6245 - Remove four (4) corner screws
Instruction
Published
11/28/2022 1:16 PM
5296 - Use small Phillips (PH1) screwdriver. Retain screws.
Remark
Published
10/24/2022 9:12 AM
6244 -
Remark
Published
11/28/2022 1:19 PM
6247 - 6243 - Remove four (4) jack screws.; Remark:6241
Procedure Step
Published
11/28/2022 1:25 PM
6243 - Remove four (4) jack screws.
Instruction
Published
11/28/2022 1:21 PM
6241 - Use a 5-mm nut driver or small needle nose pliers.
Remark
Published
11/28/2022 1:22 PM
6242 -
Remark
Published
11/28/2022 1:23 PM
6255 - 6252 - Slide out serial communication assembly; Remark:6250
Procedure Step
Published
11/28/2022 1:42 PM
6253 - Caution : Ribbon cable is still attached. Only slide out serial communication assembly ...
Annotation
Published
11/28/2022 1:42 PM
6254 - Note : Do not misplace the rubber gasket.
Annotation
Published
11/28/2022 1:42 PM
6252 - Slide out serial communication assembly
Instruction
Published
11/28/2022 1:39 PM
6250 - Ribbon cable is still attached internally. Pull panel until ribbon cable is a...
Remark
Published
11/28/2022 1:40 PM
6251 -
Remark
Published
11/28/2022 1:41 PM
6258 - 6257 - Disconnect ribbon cable; Remark:6256
Procedure Step
Published
11/28/2022 1:44 PM
6257 - Disconnect ribbon cable
Instruction
Published
11/28/2022 1:43 PM
6256 -
Remark
Published
11/28/2022 1:44 PM
6261 - 6245 - Remove four (4) corner screws; Remark:5296
Procedure Step
Published
11/28/2022 1:49 PM
6260 - Caution : Do not remove the two (2) center screws.
Annotation
Published
11/28/2022 1:49 PM
6259 -
Remark
Published
11/28/2022 1:48 PM
6265 - 6264 - Note the notch where internal board mounted; Remark:6262
Procedure Step
Published
11/28/2022 1:52 PM
6264 - Note the notch where internal board mounted
Instruction
Published
11/28/2022 1:51 PM
6262 - It is recommended to mark the location with a permanent marker.
Remark
Published
11/28/2022 1:51 PM
6263 -
Remark
Published
11/28/2022 1:52 PM
6268 - 5702 - Remove electronics; Remark:6266
Procedure Step
Published
11/28/2022 1:56 PM
6267 - Note : Do not lose the gasket used to seal around the seam of the plate face to the ...
Annotation
Published
11/28/2022 1:55 PM
5702 - Remove electronics
Instruction
Published
11/03/2022 10:50 AM
6266 -
Remark
Published
11/28/2022 1:55 PM
6277 - 6276 - Inspect FHT 681 Amplifier; Remark:
Procedure Step
Published
11/28/2022 3:22 PM
6276 - Inspect FHT 681 Amplifier
Instruction
Published
11/28/2022 3:22 PM
6274 - 6273 - Check for loose debris; Remark:
Procedure Step
Published
11/28/2022 3:23 PM
6273 - Check for loose debris
Instruction
Published
11/28/2022 3:23 PM
6275 - 6271 - Check for loose connection mounts; Remark:6269
Procedure Step
Published
11/28/2022 3:27 PM
6272 - Caution : Do not rotate the whole connection assembly or it may break the attached resi...
Annotation
Published
11/28/2022 3:27 PM
6271 - Check for loose connection mounts
Instruction
Published
11/28/2022 3:24 PM
6269 - Check that the two (2) neutron detector and one (1) gamma cable connector gro...
Remark
Published
11/28/2022 3:25 PM
6270 -
Remark
Published
11/28/2022 3:26 PM
6281 - 6280 - Reseat ribbon cable; Remark:6278
Procedure Step
Published
11/28/2022 3:30 PM
6280 - Reseat ribbon cable
Instruction
Published
11/28/2022 3:29 PM
6278 - Disconnect and reconnect ribbon cable several times to remove oxidation. Veri...
Remark
Published
11/28/2022 3:29 PM
6279 -
Remark
Published
11/28/2022 3:30 PM
6287 - 6286 - Reassemble FHT 681 Amplifier; Remark:
Procedure Step
Published
11/28/2022 3:33 PM
6286 - Reassemble FHT 681 Amplifier
Instruction
Published
11/28/2022 3:33 PM
6285 - 5720 - Replace electronics; Remark:6282
Procedure Step
Published
11/28/2022 3:36 PM
5720 - Replace electronics
Instruction
Published
11/03/2022 1:11 PM
6282 - Align circuit board with fourth slot from bottom of enclosure and slide into ...
Remark
Published
11/28/2022 3:34 PM
6283 -
Remark
Published
11/28/2022 3:35 PM
6284 -
Remark
Published
11/28/2022 3:36 PM
6289 - 5718 - Align gasket; Remark:5717
Procedure Step
Published
11/28/2022 3:39 PM
6288 - Caution : If the gasket is misaligned, the instrument could show false alarms due to RF...
Annotation
Published
11/28/2022 3:39 PM
5718 - Align gasket
Instruction
Published
11/03/2022 1:16 PM
5717 - Verify gasket is aligned between housing and end panel before inserting screw...
Remark
Published
11/03/2022 1:18 PM
6345 -
Remark
Published
11/29/2022 10:31 AM
6293 - 6292 - Replace four (4) corner screws; Remark:6290
Procedure Step
Published
11/29/2022 8:08 AM
6292 - Replace four (4) corner screws
Instruction
Published
11/29/2022 8:06 AM
6290 - Use small Phillips (PH1) screwdriver. Attach each screw loosely until all are...
Remark
Published
11/29/2022 8:07 AM
6291 -
Remark
Published
11/29/2022 8:08 AM
6298 - 6297 - Verify RS-232 gaskets are in place; Remark:6296
Procedure Step
Published
11/29/2022 8:12 AM
6297 - Verify RS-232 gaskets are in place
Instruction
Published
11/29/2022 8:10 AM
6296 -
Remark
Published
11/29/2022 8:12 AM
6299 - 6295 - Reconnect ribbon cable; Remark:6294
Procedure Step
Published
11/29/2022 8:14 AM
6295 - Reconnect ribbon cable
Instruction
Published
11/29/2022 8:13 AM
6294 -
Remark
Published
11/29/2022 8:14 AM
6307 - 5718 - Align gasket; Remark:5717
Procedure Step
Published
11/29/2022 8:19 AM
6306 -
Remark
Published
11/29/2022 8:19 AM
6308 - 6305 - Insert serial port face; Remark:6303
Procedure Step
Published
11/29/2022 8:23 AM
6305 - Insert serial port face
Instruction
Published
11/29/2022 8:20 AM
6303 - Align serial port openings with internal serial port connectors.
Remark
Published
11/29/2022 8:21 AM
6304 -
Remark
Published
11/29/2022 8:23 AM
6309 - 6302 - Insert four (4) jack screws; Remark:6300
Procedure Step
Published
11/29/2022 8:25 AM
6302 - Insert four (4) jack screws
Instruction
Published
11/29/2022 8:23 AM
6300 - Attach each screw loosely until all are inserted and then tighten. Use 5-mm n...
Remark
Published
11/29/2022 8:24 AM
6301 -
Remark
Published
11/29/2022 8:25 AM
6312 - 6311 - Insert four (4) corner screws; Remark:6290
Procedure Step
Published
11/29/2022 8:30 AM
6311 - Insert four (4) corner screws
Instruction
Published
11/29/2022 8:28 AM
6310 -
Remark
Published
11/29/2022 8:30 AM
6322 - 6321 - Reinstall FHT 681 Amplifier; Remark:
Procedure Step
Published
11/29/2022 8:37 AM
6321 - Reinstall FHT 681 Amplifier
Instruction
Published
11/29/2022 8:37 AM
6319 - 6318 - Connect FHT 681 amplifier to power supply module; Remark:6316
Procedure Step
Published
11/29/2022 8:40 AM
6318 - Connect FHT 681 amplifier to power supply module
Instruction
Published
11/29/2022 8:38 AM
6316 - A significant force might be required to rejoin the components. A snap should...
Remark
Published
11/29/2022 8:39 AM
6317 -
Remark
Published
11/29/2022 8:40 AM
6320 - 6315 - Reconnect neutron detectors; Remark:6313
Procedure Step
Published
11/29/2022 8:44 AM
6315 - Reconnect neutron detectors
Instruction
Published
11/29/2022 8:41 AM
6313 - There are two (2) neutron detectors. Push connector onto detector. Turn colla...
Remark
Published
11/29/2022 8:43 AM
6314 -
Remark
Published
11/29/2022 8:44 AM
6331 - 6330 - Reconnect RS-232 jumper and distribution box; Remark:5670
Procedure Step
Published
11/29/2022 9:15 AM
6330 - Reconnect RS-232 jumper and distribution box
Instruction
Published
11/29/2022 9:13 AM
6329 -
Remark
Published
11/29/2022 9:15 AM
6332 - 6328 - Reseat gamma connectors; Remark:6326
Procedure Step
Published
11/29/2022 9:18 AM
6328 - Reseat gamma connectors
Instruction
Published
11/29/2022 9:15 AM
6326 - The gamma detector is connected at the FHT 681 amplifier at the connection la...
Remark
Published
11/30/2022 12:21 PM
6327 -
Remark
Published
11/29/2022 9:18 AM
6333 - 6325 - Repack backpack; Remark:6323
Procedure Step
Published
11/29/2022 9:20 AM
6325 - Repack backpack
Instruction
Published
11/29/2022 9:18 AM
6323 - Slide the protective foam assembly into backpack
Remark
Published
11/29/2022 9:19 AM
6324 -
Remark
Published
11/29/2022 9:20 AM
6344 - 1383 - Close backpack; Remark:6343
Procedure Step
Published
11/29/2022 10:11 AM
1383 - Close backpack
Instruction
Published
11/19/2020 5:23 PM
6343 -
Remark
Published
11/29/2022 10:11 AM
6342 - 6341 - Perform Gamma High Voltage Adjustment; Remark:6340
Procedure Step
Published
11/29/2022 10:13 AM
6341 - Perform Gamma High Voltage Adjustment
Instruction
Published
11/29/2022 10:12 AM
6340 - DET-HHD-THR-PAK-RM05, PackEye Gamma High Voltage Adjustment.
Remark
Published
11/29/2022 10:13 AM
6339 - 319 - Perform operational test; Remark:6337
Procedure Step
Published
04/08/2025 2:14 PM
319 - Perform operational test
Instruction
Published
06/10/2021 8:31 PM
6337 - DET-HHD-THR-PAK-RM01, PackEye Operational Test.
Remark
Published
11/29/2022 10:14 AM
322 - 321 - Document maintenance actions; Remark:
Procedure Step
Published
06/17/2021 9:49 AM
321 - Document maintenance actions
Instruction
Published
04/21/2025 11:19 AM
2869 - 2585 - Document maintenance performed; Remark:2866
Procedure Step
Published
06/18/2021 5:58 PM
2585 - Document maintenance performed
Instruction
Published
07/09/2021 12:15 PM
2866 - Record observations, times, and results for the maintenance report.
Remark
Published
04/21/2025 11:39 AM
4706 - 4705 - Submit report; Remark:4864
Procedure Step
Published
06/29/2022 9:50 AM
4705 - Submit report
Instruction
Published
06/29/2022 9:50 AM
4864 - As specified by management or contractual obligations.
Remark
Published
07/28/2022 1:36 PM
Corrective Maintenance Procedure
Document Type
Published
03/02/2020 3:32 PM
30 minutes
Duration
Published
04/01/2020 11:35 AM
As Needed
Frequency
Published
04/01/2020 11:36 AM
Caution
Annotation Type
Published
03/02/2020 3:24 PM
Note
Annotation Type
Published
03/02/2020 3:25 PM
Technician 2
Skill Level
Published
04/09/2020 1:17 AM
5-mm (1/4 inch) nut driver or socket
Tools
Published
05/14/2020 3:21 PM
Small Phillips (PH1) screwdriver
Tools
Published
05/14/2020 2:48 PM
Small slotted (flathead) screwdriver
Tools
Published
09/11/2020 11:23 AM
Small needle nose pliers
Tools
Published
11/21/2022 9:06 AM
Power off Packeye
Image
Published
02/19/2022 1:48 AM
packeye_di_opentop_redarrow_00758.jpg
Image
Published
10/20/2023 12:55 PM
packeye_di_sidebuckle_open_outside.jpg
Image
Published
10/24/2023 10:18 AM
packeye_di_content_remove_4arrow.jpg
Image
Published
10/24/2023 10:20 AM
packeye_di_expose681_redbox.jpg
Image
Published
10/24/2023 10:23 AM
packeye_di_681removepmt1connector.jpg
Image
Published
10/24/2023 10:24 AM
packeye_di_rs232_distrocable_remove_2arrows.jpg
Image
Published
10/24/2023 10:30 AM
packeye_di_681powermodule_rotate.jpg
Image
Published
10/24/2023 10:33 AM
packeye_di_neutron_disconnect12.jpg
Image
Published
10/24/2023 10:34 AM
packeye_di_681powermodule_split.jpg
Image
Published
10/24/2023 10:36 AM
packeye_di_681serial_cornerscrews_4circle.jpg
Image
Published
10/24/2023 10:39 AM
packeye_di_681_9pinplugscrews_4circle.jpg
Image
Published
10/24/2023 10:40 AM
packeye_di_681serialcomm_remove_2arrow.jpg
Image
Published
10/24/2023 10:42 AM
packeye_di_681serialcomm_removeconnector.jpg
Image
Published
10/24/2023 10:44 AM
packeye_di_681pmt_cornerscrews_2cross4circle.jpg
Image
Published
10/24/2023 10:27 AM
packeye_di_681electronicsPCB_4thslot.jpg
Image
Published
10/24/2023 10:45 AM
packeye_di_681electronicsPCB_remove.jpg
Image
Published
10/24/2023 10:46 AM
packeye_di_681electronics_groundingnut_3circle.jpg
Image
Published
10/24/2023 10:47 AM
packeye_di_681ribboncable.jpg
Image
Published
10/24/2023 10:48 AM
packeye_di_681electronicsPCB_install.jpg
Image
Published
10/24/2023 10:49 AM
packeye_di_681pmt_EMIgasket_5arrow.jpg
Image
Published
10/24/2023 10:51 AM
packeye_di_681pmt_cornerscrews_4circle.jpg
Image
Published
10/24/2023 10:26 AM
packeye_di_681electronics_rs232gasket_4arrow.jpg
Image
Published
10/24/2023 10:53 AM
packeye_di_681serialcomm_installconnector.jpg
Image
Published
10/24/2023 10:54 AM
packeye_di_681rs232_EMIgasket_5arrow.jpg
Image
Published
10/24/2023 10:56 AM
packeye_di_681serialcomm_install_1arrow.jpg
Image
Published
10/24/2023 10:55 AM
packeye_di_681powermodule_join.jpg
Image
Published
10/24/2023 10:37 AM
packeye_di_neutron_connect21.jpg
Image
Published
10/24/2023 10:35 AM
packeye_di_rs232_distrocable_install_2arrows.jpg
Image
Published
10/24/2023 10:32 AM
packeye_di_681installpmt1connector.jpg
Image
Published
10/24/2023 10:25 AM
packeye_di_content_insert_2arrow.jpg
Image
Published
10/24/2023 10:21 AM
packeye_di_closetop_redarrow.jpg
Image
Published
10/24/2023 10:59 AM

PackEye Operation

Last Updated: 04/26/2025 1:39 AM

The following table lists all the components that make up the document.

Title Type Status Last Updated
Thermo FHT1377 PackEye
Device
Published
10/28/2024 3:37 PM
3983 - 257 - Prepare instrument; Remark:
Procedure Step
Published
04/14/2022 3:18 PM
3978 - Note : Do not remove components from the backpack. Apply a rain c...
Annotation
Published
04/13/2025 5:36 PM
257 - Prepare instrument
Instruction
Published
04/11/2025 9:07 PM
3984 - 3969 - Disconnect instrument from charger (if needed); Remark:3946
Procedure Step
Published
04/14/2022 3:12 PM
3979 - Note : The battery takes 12 to 18 hours to fully charge. The backup battery and back...
Annotation
Published
04/14/2022 7:54 AM
3969 - Disconnect instrument from charger (if needed)
Instruction
Published
04/14/2022 7:41 AM
3946 - Rotate the collar counterclockwise and pull.
Remark
Published
04/12/2022 1:37 PM
786 - 219 - Verify there are no sources of radiation near instrument; Remark:7
Procedure Step
Published
04/20/2025 6:37 PM
219 - Verify there are no sources of radiation near instrument
Instruction
Published
04/12/2025 4:20 PM
7 - No Radiation symbol
Remark
Published
07/12/2021 1:34 PM
3852 - 220 - Power on instrument; Remark:3836
Procedure Step
Published
03/29/2022 1:59 AM
220 - Power on instrument
Instruction
Published
04/06/2025 7:00 PM
3836 - Press power button on the indicator unit for approximately 1 second.
Remark
Published
03/29/2022 1:05 AM
3853 - 612 - Wait for instrument to complete start-up sequence; Remark:3837
Procedure Step
Published
04/13/2025 6:49 PM
612 - Wait for instrument to complete start-up sequence
Instruction
Published
04/13/2025 6:38 PM
3837 - Initialization and background measurement may take about 20 seconds. During t...
Remark
Published
03/29/2022 1:08 AM
3854 - 3825 - Verify instrument is ready; Remark:3838
Procedure Step
Published
03/29/2022 2:01 AM
3825 - Verify instrument is ready
Instruction
Published
03/28/2022 6:15 PM
3838 - The flashing green nat light indicates PackEye is ready for ...
Remark
Published
03/29/2022 1:10 AM
3990 - 2295 - Verify sufficient battery charge; Remark:3947
Procedure Step
Published
04/15/2022 11:19 AM
2295 - Verify sufficient battery charge
Instruction
Published
04/06/2021 4:43 PM
3947 - Press and hold neutron button. If battery light is solid, there is sufficient...
Remark
Published
04/12/2022 1:40 PM
3991 - 831 - Adjust volume as needed; Remark:3948
Procedure Step
Published
04/15/2022 11:23 AM
831 - Adjust volume as needed
Instruction
Published
10/26/2020 5:33 PM
3948 - To increase volume, hold the power button and press the gamm...
Remark
Published
04/12/2022 1:42 PM
3949 - To decrease volume, hold the power button and press neutron ...
Remark
Published
04/12/2022 1:44 PM
3992 - 3974 - Select mode for operation; Remark:3950
Procedure Step
Published
04/15/2022 11:22 AM
3974 - Select mode for operation
Instruction
Published
04/14/2022 7:44 AM
3950 - Briefly press the power button to switch between Alarm (Search) mode and Chir...
Remark
Published
04/12/2022 1:47 PM
3951 - Alarm (Search) mode: green LED is off.
Remark
Published
04/12/2022 1:48 PM
3952 - Chirper (Finder) mode: green LED is on.
Remark
Published
04/12/2022 1:50 PM
3994 - 319 - Perform operational test; Remark:3964
Procedure Step
Published
04/15/2022 11:28 AM
319 - Perform operational test
Instruction
Published
06/10/2021 8:31 PM
3964 - It is recommended to perform an operational test daily before use. DET-HHD-TH...
Remark
Published
04/12/2022 2:12 PM
410 - 7519 - Locate radioactive material; Remark:
Procedure Step
Published
04/13/2025 6:17 PM
7519 - Locate radioactive material
Instruction
Published
04/13/2025 5:47 PM
3857 - 3827 - Select Alarm mode; Remark:3841
Procedure Step
Published
03/29/2022 2:04 AM
3827 - Select Alarm mode
Instruction
Published
03/28/2022 6:17 PM
3841 - The green LED is off. Briefly press power button to change modes.
Remark
Published
03/29/2022 1:15 AM
3993 - 3977 - Search area; Remark:3953
Procedure Step
Published
04/15/2022 11:25 AM
3977 - Search area
Instruction
Published
04/14/2022 7:47 AM
3953 - Use search techniques appropriate for the situation.
Remark
Published
04/12/2022 1:51 PM
3995 - 367 - Observe instrument response; Remark:3954
Procedure Step
Published
04/15/2022 11:53 AM
3980 - Note : It is normal to observe up to two radiation level lights due to background fl...
Annotation
Published
04/14/2022 7:56 AM
367 - Observe instrument response
Instruction
Published
06/11/2021 9:21 AM
3954 - More than two flashing orange lights indicate the detection of a gamma source...
Remark
Published
04/12/2022 1:53 PM
3955 - More than two flashing blue lights indicate the detection of a neutron source...
Remark
Published
04/12/2022 1:55 PM
3996 - 2357 - Acknowledge alarms; Remark:3956
Procedure Step
Published
04/15/2022 11:55 AM
2357 - Acknowledge alarms
Instruction
Published
07/23/2021 9:29 PM
3956 - Press gamma button to acknowledge (ack) a gamma alarm.
Remark
Published
04/12/2022 1:56 PM
3957 - Press neutron button to acknowledge (ack) a neutron alarm.
Remark
Published
04/12/2022 1:58 PM
3997 - 3831 - Select Chirper mode; Remark:3958
Procedure Step
Published
04/15/2022 11:57 AM
3831 - Select Chirper mode
Instruction
Published
03/28/2022 6:21 PM
3958 - Briefly press the power button. The green LED should be on. In Chirper (Finde...
Remark
Published
04/12/2022 2:00 PM
3998 - 846 - Walk slowly in the area of interest; Remark:3959
Procedure Step
Published
04/15/2022 11:58 AM
846 - Walk slowly in the area of interest
Instruction
Published
07/29/2021 4:15 PM
3959 - IO PackEye Walk Slow Around Car
Remark
Published
04/12/2022 2:02 PM
3999 - 367 - Observe instrument response; Remark:3960
Procedure Step
Published
04/15/2022 11:59 AM
3960 - IO PackEye Gamma Alarm Indicator Red Box
Remark
Published
04/12/2022 2:04 PM
4000 - 853 - Locate area with highest level of radiation; Remark:3961
Procedure Step
Published
04/15/2022 12:01 PM
853 - Locate area with highest level of radiation
Instruction
Published
10/26/2020 6:59 PM
3961 - A gradual 360° turn might be needed to determine the direction of the source...
Remark
Published
04/12/2022 2:06 PM
405 - 368 - Mark point(s) of interest; Remark:4277
Procedure Step
Published
04/20/2025 5:44 PM
368 - Mark point(s) of interest
Instruction
Published
06/11/2021 9:23 AM
4277 - Place a marker (tape, pencil, etc.) on points exhibiting elevated radiation. ...
Remark
Published
04/20/2025 5:37 PM
4002 - 375 - Document results; Remark:3963
Procedure Step
Published
04/15/2022 12:03 PM
375 - Document results
Instruction
Published
06/11/2021 9:37 AM
3963 - Document the distribution of radiation, locations of concentrated radiation l...
Remark
Published
04/12/2022 2:11 PM
3869 - 313 - Power off instrument; Remark:3850
Procedure Step
Published
03/29/2022 2:23 AM
313 - Power off instrument
Instruction
Published
07/23/2021 2:41 PM
3850 - Press and hold the power button for approximately 10 seconds until indicator ...
Remark
Published
03/29/2022 1:38 AM
3985 - 315 - Connect charger; Remark:3965
Procedure Step
Published
04/14/2022 3:13 PM
315 - Connect charger
Instruction
Published
07/20/2021 10:45 AM
3965 - Open the backpack to access the power module. Push the connector and turn the...
Remark
Published
04/12/2022 2:15 PM
Operator Procedure
Document Type
Published
03/02/2020 3:31 PM
Note
Annotation Type
Published
03/02/2020 3:25 PM
Earpiece (optional)
Tools
Published
04/11/2022 1:05 PM
packeye_di_charger_disconnect_redarrow_00782.jpg
Image
Published
10/20/2023 12:54 PM
No Radiation Symbol
Image
Published
08/13/2024 2:56 PM
packeye_ui_power_on_00719
Image
Published
02/07/2022 1:46 AM
PackEye art light highlighted
Image
Published
02/19/2022 1:48 AM
PackEye Nat light flashing
Image
Published
02/19/2022 1:48 AM
Packeye battery charge
Image
Published
02/19/2022 1:48 AM
Packeye adjust gamma volume
Image
Published
04/15/2022 1:06 PM
Neutron_volume.png
Image
Published
02/19/2022 1:48 AM
Power button and nat light
Image
Published
02/19/2022 1:48 AM
Alarm mode
Image
Published
02/19/2022 1:48 AM
Chirper mode
Image
Published
02/19/2022 1:48 AM
Packeye search area
Image
Published
02/19/2022 1:48 AM
Gamma alarm
Image
Published
02/19/2022 1:48 AM
Neutron alarm
Image
Published
02/19/2022 1:48 AM
Packeye acknowledge gamma alarm
Image
Published
02/19/2022 1:48 AM
Packeye walk slowly
Image
Published
02/19/2022 1:48 AM
Packeye 360 degree turn
Image
Published
02/19/2022 1:48 AM
Mark_Source_Location_Trefoil
Image
Published
02/19/2023 10:54 AM
Power off Packeye
Image
Published
02/19/2022 1:48 AM
packeye_di_opentop_redarrow_00758.jpg
Image
Published
10/20/2023 12:55 PM
packeye_di_charger_connect_redarrow_00783.jpg
Image
Published
10/20/2023 12:53 PM

PackEye Operational Test

Last Updated: 04/26/2025 1:39 AM

The following table lists all the components that make up the document.

Title Type Status Last Updated
Thermo FHT1377 PackEye
Device
Published
10/28/2024 3:37 PM
247 - 257 - Prepare instrument; Remark:
Procedure Step
Published
04/11/2025 9:08 PM
257 - Prepare instrument
Instruction
Published
04/11/2025 9:07 PM
786 - 219 - Verify there are no sources of radiation near instrument; Remark:7
Procedure Step
Published
04/20/2025 6:37 PM
219 - Verify there are no sources of radiation near instrument
Instruction
Published
04/12/2025 4:20 PM
7 - No Radiation symbol
Remark
Published
07/12/2021 1:34 PM
3852 - 220 - Power on instrument; Remark:3836
Procedure Step
Published
03/29/2022 1:59 AM
220 - Power on instrument
Instruction
Published
04/06/2025 7:00 PM
3836 - Press power button on the indicator unit for approximately 1 second.
Remark
Published
03/29/2022 1:05 AM
3853 - 612 - Wait for instrument to complete start-up sequence; Remark:3837
Procedure Step
Published
04/13/2025 6:49 PM
612 - Wait for instrument to complete start-up sequence
Instruction
Published
04/13/2025 6:38 PM
3837 - Initialization and background measurement may take about 20 seconds. During t...
Remark
Published
03/29/2022 1:08 AM
3854 - 3825 - Verify instrument is ready; Remark:3838
Procedure Step
Published
03/29/2022 2:01 AM
3825 - Verify instrument is ready
Instruction
Published
03/28/2022 6:15 PM
3838 - The flashing green nat light indicates PackEye is ready for ...
Remark
Published
03/29/2022 1:10 AM
3855 - 3826 - Verify fail light is off; Remark:3839
Procedure Step
Published
03/29/2022 2:02 AM
3826 - Verify fail light is off
Instruction
Published
03/28/2022 6:16 PM
3839 - Solid yellow light: neutron detector or electronic failure.
Remark
Published
03/29/2022 1:12 AM
3840 - Flashing yellow light: high gamma radiation level or gamma detector failure.
Remark
Published
03/29/2022 1:13 AM
3856 - 1437 - Verify Response to Gamma Source; Remark:
Procedure Step
Published
03/29/2022 2:03 AM
1437 - Verify Response to Gamma Source
Instruction
Published
09/01/2020 7:45 PM
3857 - 3827 - Select Alarm mode; Remark:3841
Procedure Step
Published
03/29/2022 2:04 AM
3827 - Select Alarm mode
Instruction
Published
03/28/2022 6:17 PM
3841 - The green LED is off. Briefly press power button to change modes.
Remark
Published
03/29/2022 1:15 AM
3858 - 3828 - Place gamma source on instrument; Remark:3842
Procedure Step
Published
03/29/2022 2:05 AM
3828 - Place gamma source on instrument
Instruction
Published
03/28/2022 6:18 PM
3842 - IO PackEye Gamma Source Placed
Remark
Published
03/29/2022 1:23 AM
3859 - 1439 - Verify instrument responds to radioactive source; Remark:3843
Procedure Step
Published
03/29/2022 2:06 AM
1439 - Verify instrument responds to radioactive source
Instruction
Published
06/29/2022 11:50 PM
3843 - Additional gamma indicator lights will illuminate on indicator unit and an au...
Remark
Published
03/29/2022 1:22 AM
3860 - 3829 - Acknowledge gamma alarm; Remark:3844
Procedure Step
Published
03/29/2022 2:07 AM
3829 - Acknowledge gamma alarm
Instruction
Published
03/28/2022 6:20 PM
3844 - Briefly press gamma button to acknowledge alarm.
Remark
Published
03/29/2022 1:25 AM
3835 - 3830 - Move source away from instrument; Remark:246
Procedure Step
Published
03/28/2022 6:31 PM
3830 - Move source away from instrument
Instruction
Published
03/28/2022 6:20 PM
246 - IO No source trefoil
Remark
Published
10/07/2024 11:39 AM
3861 - 3831 - Select Chirper mode; Remark:3845
Procedure Step
Published
03/29/2022 2:08 AM
3831 - Select Chirper mode
Instruction
Published
03/28/2022 6:21 PM
3845 - The green LED is on. Briefly press power button to change modes.
Remark
Published
03/29/2022 1:26 AM
3871 - 3828 - Place gamma source on instrument; Remark:3842
Procedure Step
Published
04/04/2022 11:00 AM
3862 - 1439 - Verify instrument responds to radioactive source; Remark:3846
Procedure Step
Published
03/29/2022 2:09 AM
3846 - Additional gamma indicator lights will illuminate. Audible chirper pitch will...
Remark
Published
03/29/2022 1:28 AM
3872 - 3830 - Move source away from instrument; Remark:246
Procedure Step
Published
04/04/2022 11:00 AM
3863 - 3832 - Verify Response to Neutron Source; Remark:
Procedure Step
Published
03/29/2022 2:10 AM
3832 - Verify Response to Neutron Source
Instruction
Published
03/29/2022 2:56 AM
3864 - 3827 - Select Alarm mode; Remark:3841
Procedure Step
Published
03/29/2022 2:11 AM
3865 - 3833 - Place neutron source on instrument; Remark:3847
Procedure Step
Published
03/29/2022 2:17 AM
3833 - Place neutron source on instrument
Instruction
Published
03/28/2022 6:24 PM
3847 - IO PackEye Neutron Source Placed
Remark
Published
03/29/2022 1:32 AM
3866 - 1439 - Verify instrument responds to radioactive source; Remark:3848
Procedure Step
Published
03/29/2022 2:19 AM
3848 - Additional neutron indicator lights will illuminate and an alarm will sound. ...
Remark
Published
03/29/2022 1:34 AM
3867 - 3834 - Acknowledge neutron alarm; Remark:3849
Procedure Step
Published
03/29/2022 2:20 AM
3834 - Acknowledge neutron alarm
Instruction
Published
03/28/2022 6:25 PM
3849 - Briefly press neutron button to acknowledge alarm.
Remark
Published
03/29/2022 1:35 AM
3873 - 3833 - Place neutron source on instrument; Remark:3847
Procedure Step
Published
04/04/2022 11:15 AM
3868 - 1439 - Verify instrument responds to radioactive source; Remark:3851
Procedure Step
Published
04/04/2022 11:03 AM
3851 - Additional neutron indicator lights will illuminate and an alarm will sound. ...
Remark
Published
04/01/2022 1:26 PM
3869 - 313 - Power off instrument; Remark:3850
Procedure Step
Published
03/29/2022 2:23 AM
313 - Power off instrument
Instruction
Published
07/23/2021 2:41 PM
3850 - Press and hold the power button for approximately 10 seconds until indicator ...
Remark
Published
03/29/2022 1:38 AM
253 - 242 - Document and report any unresolved problems; Remark:
Procedure Step
Published
06/22/2021 10:23 AM
242 - Document and report any unresolved problems
Instruction
Published
04/21/2025 11:45 AM
Routine Maintenance Procedure
Document Type
Published
03/02/2020 3:31 PM
10 minutes
Duration
Published
04/01/2020 11:35 AM
Annually
Frequency
Published
04/01/2020 11:37 AM
Daily
Frequency
Published
04/01/2020 11:36 AM
Technician 1
Skill Level
Published
05/14/2020 2:56 PM
None
Tools
Published
05/06/2020 9:50 PM
No Radiation Symbol
Image
Published
08/13/2024 2:56 PM
packeye_ui_power_on_00719
Image
Published
02/07/2022 1:46 AM
PackEye art light highlighted
Image
Published
02/19/2022 1:48 AM
PackEye Nat light flashing
Image
Published
02/19/2022 1:48 AM
packeye_fail_solid_yellow.jpg
Image
Published
10/20/2023 10:36 AM
packeye_fail_flashing_yellow.jpg
Image
Published
10/20/2023 10:36 AM
Alarm mode
Image
Published
02/19/2022 1:48 AM
packeye_radsource_placeright.jpg
Image
Published
10/20/2023 10:46 AM
packeye_gamma_radsource_indicator.jpg
Image
Published
10/20/2023 10:39 AM
Packeye acknowledge gamma alarm
Image
Published
02/19/2022 1:48 AM
Chirper mode
Image
Published
02/19/2022 1:48 AM
packeye_gamma_radsource_chirp.jpg
Image
Published
10/20/2023 10:38 AM
packeye_neutronradsource_placeright.jpg
Image
Published
10/20/2023 10:45 AM
packeye_neutron_radsource_indicator.jpg
Image
Published
10/20/2023 10:44 AM
Acknowledge_neutron.png
Image
Published
02/19/2022 1:48 AM
packeye_neutron_radsource_chirp.jpg
Image
Published
10/20/2023 10:43 AM
Power off Packeye
Image
Published
02/19/2022 1:48 AM