Viken Detection Nighthawk HBI XP WAD |
Device
|
Published
|
06/04/2024 9:41 AM
|
10489 - 257 - Prepare instrument; Remark: |
Procedure Step
|
Published
|
12/06/2023 3:03 PM
|
10487 - Warning : Prior to use, the operator should read and understand the complete user’s g... |
Annotation
|
Published
|
12/06/2023 3:02 PM
|
10488 - Caution : Do not block the air intake vents or outlet vents when the instrument is in u... |
Annotation
|
Published
|
12/06/2023 3:03 PM
|
257 - Prepare instrument |
Instruction
|
Published
|
04/11/2025 9:07 PM
|
10485 - 10484 - Insert battery pack; Remark:10483 |
Procedure Step
|
Published
|
12/06/2023 3:07 PM
|
10484 - Insert battery pack |
Instruction
|
Published
|
12/06/2023 3:04 PM
|
10483 - |
Remark
|
Published
|
12/06/2023 3:07 PM
|
10486 - 220 - Power on instrument; Remark:10482 |
Procedure Step
|
Published
|
12/06/2023 4:50 PM
|
220 - Power on instrument |
Instruction
|
Published
|
04/06/2025 7:00 PM
|
10482 - Press and hold the Power button. |
Remark
|
Published
|
12/06/2023 4:48 PM
|
10498 - 10497 - Select HBI application; Remark:10496 |
Procedure Step
|
Published
|
12/06/2023 4:55 PM
|
10497 - Select HBI application |
Instruction
|
Published
|
12/06/2023 4:55 PM
|
10496 - On the home screen, tap on the Viken icon. |
Remark
|
Published
|
12/06/2023 4:55 PM
|
10499 - 10494 - Log into the application; Remark:10493 |
Procedure Step
|
Published
|
12/06/2023 5:00 PM
|
10495 - Note : See the user’s guide to set up the first administrator. Keep a secure recor... |
Annotation
|
Published
|
12/06/2023 5:00 PM
|
10494 - Log into the application |
Instruction
|
Published
|
12/06/2023 5:00 PM
|
10493 - Type in your username and password. |
Remark
|
Published
|
12/06/2023 5:00 PM
|
10500 - 10492 - Acknowledge warnings; Remark:10491 |
Procedure Step
|
Published
|
12/06/2023 5:04 PM
|
10492 - Acknowledge warnings |
Instruction
|
Published
|
12/06/2023 5:04 PM
|
10491 - |
Remark
|
Published
|
12/06/2023 5:04 PM
|
10505 - 10503 - Perform a system check; Remark: |
Procedure Step
|
Published
|
12/07/2023 9:17 AM
|
10504 - Note : It is recommended to perform a system check if you have not used the instrume... |
Annotation
|
Published
|
12/07/2023 9:17 AM
|
10503 - Perform a system check |
Instruction
|
Published
|
12/07/2023 9:17 AM
|
10502 - 10501 - Tap Menu icon, select Settings, if needed; Remark:10518 |
Procedure Step
|
Published
|
12/07/2023 9:24 AM
|
10501 - Tap Menu icon, select Settings, if needed |
Instruction
|
Published
|
12/07/2023 9:24 AM
|
10518 - The system check screen will automatically pop-up if it has been more than 7 ... |
Remark
|
Published
|
12/07/2023 1:47 PM
|
10519 - 10517 - Place instrument on sample radiation shield; Remark:10516 |
Procedure Step
|
Published
|
12/07/2023 1:51 PM
|
10517 - Place instrument on sample radiation shield |
Instruction
|
Published
|
12/07/2023 1:51 PM
|
10516 - Place face down on flat surface. |
Remark
|
Published
|
12/07/2023 1:51 PM
|
10520 - 10515 - Tap YES on screen; Remark:10514 |
Procedure Step
|
Published
|
12/07/2023 1:54 PM
|
10515 - Tap YES on screen |
Instruction
|
Published
|
12/07/2023 1:54 PM
|
10514 - Viken Nighthawk system check screen YES |
Remark
|
Published
|
07/24/2024 12:02 PM
|
10521 - 10513 - Wait for system check to complete; Remark:10512 |
Procedure Step
|
Published
|
12/07/2023 1:59 PM
|
10513 - Wait for system check to complete |
Instruction
|
Published
|
12/07/2023 1:59 PM
|
10512 - This will take approximately 10 seconds. |
Remark
|
Published
|
12/07/2023 1:59 PM
|
10522 - 10511 - Tap OK on screen; Remark:10510 |
Procedure Step
|
Published
|
12/07/2023 2:01 PM
|
10511 - Tap OK on screen |
Instruction
|
Published
|
12/07/2023 2:01 PM
|
10510 - |
Remark
|
Published
|
12/07/2023 2:01 PM
|
10509 - 10506 - Conduct scan; Remark: |
Procedure Step
|
Published
|
12/07/2023 2:06 PM
|
10507 - Warning : The HBI should not be used to scan people directly. Never point the instrumen... |
Annotation
|
Published
|
12/07/2023 2:05 PM
|
10508 - Warning : Do not stare directly into the red laser beams. |
Annotation
|
Published
|
12/07/2023 2:06 PM
|
10506 - Conduct scan |
Instruction
|
Published
|
12/07/2023 2:06 PM
|
10539 - 10538 - Position instrument over item to be scanned; Remark: |
Procedure Step
|
Published
|
12/07/2023 2:10 PM
|
10538 - Position instrument over item to be scanned |
Instruction
|
Published
|
12/07/2023 2:10 PM
|
10540 - 10537 - Swipe slider to the right or touch the right side of the line; Remark:10536 |
Procedure Step
|
Published
|
12/07/2023 2:13 PM
|
10537 - Swipe slider to the right or touch the right side of the line |
Instruction
|
Published
|
12/07/2023 2:13 PM
|
10536 - The blue slider at the top of the screen must be swiped to the right edge of ... |
Remark
|
Published
|
12/07/2023 2:13 PM
|
10541 - 10535 - Press and hold the triggers; Remark:10534 |
Procedure Step
|
Published
|
12/07/2023 2:16 PM
|
10535 - Press and hold the triggers |
Instruction
|
Published
|
12/07/2023 2:16 PM
|
10534 - The triggers may be red or blue, depending on the model. The HBI will start t... |
Remark
|
Published
|
12/07/2023 2:16 PM
|
10542 - 10530 - Scan item of interest; Remark:10528 |
Procedure Step
|
Published
|
12/07/2023 2:19 PM
|
10531 - Note : Longer scan times produce larger image files, shorter scans are preferred. |
Annotation
|
Published
|
12/07/2023 2:20 PM
|
10532 - Note : There is a 30 second maximum scan time. |
Annotation
|
Published
|
12/07/2023 2:20 PM
|
10533 - Note : Multiple scans may be required to fully image an item. |
Annotation
|
Published
|
12/07/2023 2:20 PM
|
10530 - Scan item of interest |
Instruction
|
Published
|
12/07/2023 2:19 PM
|
10528 - The instrument must be moved to capture a two (2)-dimensional image. Moving t... |
Remark
|
Published
|
12/07/2023 2:19 PM
|
10529 - |
Remark
|
Published
|
12/07/2023 2:20 PM
|
10543 - 10527 - Start new scan, if needed; Remark:10526 |
Procedure Step
|
Published
|
12/07/2023 2:21 PM
|
10527 - Start new scan, if needed |
Instruction
|
Published
|
12/07/2023 2:21 PM
|
10526 - The instrument will need to be re-armed. Repeat steps 3-2 to 3-4. |
Remark
|
Published
|
12/07/2023 2:21 PM
|
10525 - 313 - Power off instrument; Remark:10523 |
Procedure Step
|
Published
|
04/07/2025 4:41 PM
|
313 - Power off instrument |
Instruction
|
Published
|
07/23/2021 2:41 PM
|
10523 - Press the Power button for 1 second. |
Remark
|
Published
|
12/07/2023 2:23 PM
|
Operator Procedure |
Document Type
|
Published
|
03/02/2020 3:31 PM
|
Warning |
Annotation Type
|
Published
|
03/02/2020 3:25 PM
|
Caution |
Annotation Type
|
Published
|
03/02/2020 3:24 PM
|
Note |
Annotation Type
|
Published
|
03/02/2020 3:25 PM
|
Viken Nighthawk-HBI Insert Battery |
Image
|
Published
|
12/06/2023 4:50 PM
|
Viken Nighthawk-HBI Power Button |
Image
|
Published
|
12/06/2023 4:50 PM
|
Viken Nighthawk home screen tap Viken icon |
Image
|
Published
|
12/06/2023 5:04 PM
|
Viken Nighthawk type username password |
Image
|
Published
|
12/06/2023 5:04 PM
|
Viken Nighthawk acknowledge warnings |
Image
|
Published
|
12/06/2023 5:04 PM
|
Viken Nighthawk menu icon settings |
Image
|
Published
|
12/07/2023 2:06 PM
|
Viken Nighthawk on sample radiation shield |
Image
|
Published
|
12/07/2023 2:06 PM
|
Viken Nighthawk face down on sample radiation shield |
Image
|
Published
|
12/07/2023 2:06 PM
|
Viken Nighthawk system check screen YES |
Image
|
Published
|
12/07/2023 2:06 PM
|
Viken Nighthawk system check running |
Image
|
Published
|
12/07/2023 2:06 PM
|
Viken Nighthawk system check successful OK |
Image
|
Published
|
12/07/2023 2:06 PM
|
Viken Nighthawk conduct scan swipe slider |
Image
|
Published
|
12/07/2023 2:23 PM
|
Viken Nighthawk press hold triggers |
Image
|
Published
|
12/07/2023 2:23 PM
|
Viken Nighthawk scan item |
Image
|
Published
|
12/07/2023 2:23 PM
|