radEAGLET Operational Test
Last Updated: 05/07/2025 1:46 AM
The following table lists all the components that make up the document.
radEAGLET Operation
Last Updated: 05/07/2025 1:46 AM
The following table lists all the components that make up the document.
TA600 Radiation Pager Operational Test
Last Updated: 05/07/2025 1:43 AM
The following table lists all the components that make up the document.
Title | Type | Status | Last Updated |
---|---|---|---|
Sensor Tech TA600 Radiation Pager | Device
|
Published
|
10/28/2024 3:51 PM
|
247 - 257 - Prepare instrument; Remark: | Procedure Step
|
Published
|
04/11/2025 9:08 PM
|
257 - Prepare instrument | Instruction
|
Published
|
04/11/2025 9:07 PM
|
786 - 219 - Verify there are no sources of radiation near instrument; Remark:7 | Procedure Step
|
Published
|
04/20/2025 6:37 PM
|
219 - Verify there are no sources of radiation near instrument | Instruction
|
Published
|
04/12/2025 4:20 PM
|
7 - No Radiation symbol | Remark
|
Published
|
07/12/2021 1:34 PM
|
7555 - 220 - Zapněte přístroj; Remark:7542 | Procedure Step
|
Published
|
06/05/2023 5:57 PM
|
220 - Power on instrument | Instruction
|
Published
|
04/06/2025 7:00 PM
|
7542 - Set instrument to audio only mode. | Remark
|
Published
|
04/13/2025 5:48 PM
|
7556 - 612 - POČKEJTE, až přístroj dokončí spouštěcí sekvenci; Remark:7512 | Procedure Step
|
Published
|
04/13/2025 6:50 PM
|
612 - Wait for instrument to complete start-up sequence | Instruction
|
Published
|
04/13/2025 6:38 PM
|
7512 - Red numerical LED display will flash while collecting background for 30 secon... | Remark
|
Published
|
10/19/2023 7:54 AM
|
7557 - 7543 - Test Audible Alarm; Remark: | Procedure Step
|
Published
|
06/05/2023 5:59 PM
|
7543 - Test Audible Alarm | Instruction
|
Published
|
06/05/2023 3:31 PM
|
7558 - 7544 - Place instrument next to source of radiation; Remark:7545 | Procedure Step
|
Published
|
06/05/2023 5:59 PM
|
7544 - Place instrument next to source of radiation | Instruction
|
Published
|
06/05/2023 3:32 PM
|
7545 - TA600 Next to Source | Remark
|
Published
|
06/05/2023 3:34 PM
|
7559 - 2936 - Zkontrolujte, že zvukový alarm funguje správně; Remark:7547 | Procedure Step
|
Published
|
06/05/2023 6:00 PM
|
2936 - Verify audible alarm functions correctly | Instruction
|
Published
|
06/15/2021 4:09 PM
|
7547 - The instrument should respond as follows: Emit an audible b... | Remark
|
Published
|
06/05/2023 5:00 PM
|
7560 - 7548 - Potvrďte alarm; Remark:7549 | Procedure Step
|
Published
|
06/05/2023 6:01 PM
|
7548 - Acknowledge alarm | Instruction
|
Published
|
06/05/2023 5:03 PM
|
7549 - Press display button to stop alarm. Otherwise, the alarm will automatically s... | Remark
|
Published
|
06/05/2023 5:07 PM
|
7561 - 7550 - Vzdalte přístroj od zdroje záření; Remark:7551 | Procedure Step
|
Published
|
06/05/2023 6:02 PM
|
7550 - Move instrument away from source of radiation | Instruction
|
Published
|
06/05/2023 5:09 PM
|
7551 - Move source away from TA600 | Remark
|
Published
|
06/05/2023 5:12 PM
|
2914 - 2912 - Test vibration alarm; Remark: | Procedure Step
|
Published
|
06/06/2022 5:28 PM
|
2912 - Test vibration alarm | Instruction
|
Published
|
06/15/2021 4:11 PM
|
7562 - 7546 - Change to vibrate mode; Remark:7552 | Procedure Step
|
Published
|
06/05/2023 6:02 PM
|
7546 - Change to vibrate mode | Instruction
|
Published
|
06/05/2023 3:35 PM
|
7552 - Set instrument to vibrate only mode. | Remark
|
Published
|
06/05/2023 5:15 PM
|
7563 - 612 - POČKEJTE, až přístroj dokončí spouštěcí sekvenci; Remark:7512 | Procedure Step
|
Published
|
04/13/2025 6:55 PM
|
7553 - Note : If dial is turned to vibrate mode quickly, the instrument will not repeat sta... | Annotation
|
Published
|
06/05/2023 5:17 PM
|
7564 - 7544 - Umístěte přístroj vedle zdroje záření; Remark:7545 | Procedure Step
|
Published
|
06/05/2023 6:05 PM
|
7565 - 2938 - Zkontrolujte, že vibrační alarm funguje správně; Remark:7554 | Procedure Step
|
Published
|
06/05/2023 6:06 PM
|
2938 - Verify vibration alarm functions correctly | Instruction
|
Published
|
06/15/2021 4:12 PM
|
7554 - The instrument should respond as follows: Vibrate | Remark
|
Published
|
06/05/2023 5:24 PM
|
7566 - 7548 - Potvrďte alarm; Remark:7549 | Procedure Step
|
Published
|
06/05/2023 6:07 PM
|
7567 - 7550 - Vzdalte přístroj od zdroje záření; Remark:7551 | Procedure Step
|
Published
|
06/05/2023 6:08 PM
|
253 - 242 - Document and report any unresolved problems; Remark: | Procedure Step
|
Published
|
06/22/2021 10:23 AM
|
242 - Document and report any unresolved problems | Instruction
|
Published
|
04/21/2025 11:45 AM
|
Routine Maintenance Procedure | Document Type
|
Published
|
03/02/2020 3:31 PM
|
Daily | Frequency
|
Published
|
04/01/2020 11:36 AM
|
Before each use | Frequency
|
Published
|
08/31/2020 5:00 PM
|
Note | Annotation Type
|
Published
|
03/02/2020 3:25 PM
|
Technician 1 | Skill Level
|
Published
|
05/14/2020 2:56 PM
|
None | Tools
|
Published
|
05/06/2020 9:50 PM
|
No Radiation Symbol | Image
|
Published
|
08/13/2024 2:56 PM
|
TA600 Audio Only | Image
|
Published
|
06/04/2023 9:55 PM
|
TA600 Background | Image
|
Published
|
06/04/2023 9:59 PM
|
TA600 Ready | Image
|
Published
|
06/04/2023 9:59 PM
|
TA600 Next to Source | Image
|
Published
|
03/29/2024 11:57 AM
|
TA600 Audible Alarm | Image
|
Published
|
06/05/2023 5:00 PM
|
TA600 Acknowledge Alarm | Image
|
Published
|
06/05/2023 5:07 PM
|
TA600 Away From Source | Image
|
Published
|
06/05/2023 5:11 PM
|
TA600 Vibrate Only | Image
|
Published
|
06/04/2023 9:56 PM
|
TA600 Vibration Alarm | Image
|
Published
|
06/05/2023 5:23 PM
|
RadSeeker Calibration
Last Updated: 05/07/2025 1:41 AM
The following table lists all the components that make up the document.
Title | Type | Status | Last Updated |
---|---|---|---|
Smiths Detection RadSeeker CS | Device
|
Published
|
06/27/2024 12:54 PM
|
5925 - 5924 - Prepare Calibration Source; Remark: | Procedure Step
|
Published
|
11/07/2022 1:09 PM
|
5924 - Prepare Calibration Source | Instruction
|
Published
|
11/07/2022 1:09 PM
|
5923 - 5922 - Position Eu-152 calibration source; Remark:5921 | Procedure Step
|
Published
|
11/07/2022 1:21 PM
|
5922 - Position Eu-152 calibration source | Instruction
|
Published
|
11/07/2022 1:10 PM
|
5921 - Position Eu-152 source in front of the detector. | Remark
|
Published
|
11/07/2022 1:21 PM
|
5920 - 5919 - Calibrate Instrument; Remark: | Procedure Step
|
Published
|
11/07/2022 1:22 PM
|
5919 - Calibrate Instrument | Instruction
|
Published
|
11/07/2022 1:22 PM
|
5914 - 5913 - Enter Advanced Mode; Remark:5912 | Procedure Step
|
Published
|
11/07/2022 1:24 PM
|
5913 - Enter Advanced Mode | Instruction
|
Published
|
11/07/2022 1:23 PM
|
5912 - Select Menu from the Detect screen. Scroll down to E... | Remark
|
Published
|
11/07/2022 1:24 PM
|
5915 - 5911 - Enter password; Remark:5910 | Procedure Step
|
Published
|
11/07/2022 1:26 PM
|
5911 - Enter password | Instruction
|
Published
|
11/07/2022 1:25 PM
|
5910 - Enter default Nuclear Smuggling Detection and Deterrence (NSDD) password | Remark
|
Published
|
11/07/2022 1:26 PM
|
5916 - 5592 - Enter Service Mode; Remark:5909 | Procedure Step
|
Published
|
11/07/2022 1:28 PM
|
5592 - Enter Service Mode | Instruction
|
Published
|
10/31/2022 11:37 AM
|
5909 - Select Enter Service Mode from the Advanced Mode menu. | Remark
|
Published
|
11/07/2022 1:28 PM
|
5917 - 5908 - Start calibration; Remark:5907 | Procedure Step
|
Published
|
11/07/2022 1:31 PM
|
5908 - Start calibration | Instruction
|
Published
|
11/07/2022 1:30 PM
|
5907 - Select Calibrate Detector. Wait several minutes for the cali... | Remark
|
Published
|
11/07/2022 1:31 PM
|
5918 - 5906 - Confirm completion; Remark:5905 | Procedure Step
|
Published
|
11/07/2022 1:32 PM
|
5906 - Confirm completion | Instruction
|
Published
|
11/07/2022 1:32 PM
|
5905 - The Calibrated message will appear indicating calibration is... | Remark
|
Published
|
11/07/2022 1:32 PM
|
5904 - 5903 - Prepare Instrument for Use; Remark: | Procedure Step
|
Published
|
11/07/2022 1:33 PM
|
5903 - Prepare Instrument for Use | Instruction
|
Published
|
11/07/2022 1:33 PM
|
5900 - 5899 - Exit Service Mode; Remark:5898 | Procedure Step
|
Published
|
11/07/2022 1:35 PM
|
5899 - Exit Service Mode | Instruction
|
Published
|
11/07/2022 1:34 PM
|
5898 - Return Back to Service Mode options. | Remark
|
Published
|
11/07/2022 1:35 PM
|
5901 - 5897 - Select Exit Advanced Mode; Remark:5957 | Procedure Step
|
Published
|
11/07/2022 1:36 PM
|
5897 - Select Exit Advanced Mode | Instruction
|
Published
|
11/07/2022 1:36 PM
|
5957 - IO RadSeeker Detect Screen Exit Advanced Mode | Remark
|
Published
|
11/15/2022 11:43 AM
|
5902 - 5896 - Restart Instrument; Remark: | Procedure Step
|
Published
|
11/07/2022 1:37 PM
|
5896 - Restart Instrument | Instruction
|
Published
|
11/07/2022 1:37 PM
|
322 - 321 - Document maintenance actions; Remark: | Procedure Step
|
Published
|
06/17/2021 9:49 AM
|
321 - Document maintenance actions | Instruction
|
Published
|
04/21/2025 11:19 AM
|
2869 - 2585 - Document maintenance performed; Remark:2866 | Procedure Step
|
Published
|
06/18/2021 5:58 PM
|
2585 - Document maintenance performed | Instruction
|
Published
|
07/09/2021 12:15 PM
|
2866 - Record observations, times, and results for the maintenance report. | Remark
|
Published
|
04/21/2025 11:39 AM
|
4706 - 4705 - Submit report; Remark:4864 | Procedure Step
|
Published
|
06/29/2022 9:50 AM
|
4705 - Submit report | Instruction
|
Published
|
06/29/2022 9:50 AM
|
4864 - As specified by management or contractual obligations. | Remark
|
Published
|
07/28/2022 1:36 PM
|
Corrective Maintenance Procedure | Document Type
|
Published
|
03/02/2020 3:32 PM
|
minutes | Duration
|
Published
|
05/26/2022 11:41 AM
|
As Needed | Frequency
|
Published
|
04/01/2020 11:36 AM
|
Technician 2 | Skill Level
|
Published
|
04/09/2020 1:17 AM
|
None | Tools
|
Published
|
05/06/2020 9:50 PM
|
radseeker_di_front_rad_symbol.jpg | Image
|
Published
|
10/10/2023 12:32 AM
|
radseeker_ui_detect_screen_menu.jpg | Image
|
Published
|
10/10/2023 12:20 AM
|
radseeker_ui_detect_screen_enter_arrow.jpg | Image
|
Published
|
10/10/2023 12:22 AM
|
radseeker_ui_detect_screen_password.jpg | Image
|
Published
|
10/10/2023 12:14 AM
|
radseeker_ui_detect_screen_enter_service_mode.jpg | Image
|
Published
|
10/10/2023 12:26 AM
|
radseeker_ui_detect_screen_calibrate_detector.jpg | Image
|
Published
|
10/10/2023 12:27 AM
|
radseeker_ui_detect_screen_calibrated.jpg | Image
|
Published
|
10/10/2023 12:26 AM
|
radseeker_ui_detect_screen_back_left_arrow.jpg | Image
|
Published
|
10/10/2023 12:27 AM
|
radseeker_ui_detect_screen_back.jpg | Image
|
Published
|
10/10/2023 12:28 AM
|
radseeker_ui_detect_screen_exit_advanced_mode.jpg | Image
|
Published
|
10/10/2023 12:21 AM
|
PackEye Battery Cycle
Last Updated: 05/07/2025 1:41 AM
The following table lists all the components that make up the document.
RadSeeker Routine Assessment
Last Updated: 05/07/2025 1:40 AM
The following table lists all the components that make up the document.
RS-350 Operational Test
Last Updated: 05/07/2025 1:40 AM
The following table lists all the components that make up the document.
Handheld Radiation Monitor Routine Assessment
Last Updated: 05/07/2025 1:40 AM
The following table lists all the components that make up the document.
Title | Type | Status | Last Updated |
---|---|---|---|
Sensor Tech Handheld Radiation Monitor | Device
|
Published
|
10/28/2024 3:52 PM
|
4384 - 4383 - Document serial number; Remark:4382 | Procedure Step
|
Published
|
06/06/2022 9:39 PM
|
4383 - Document serial number | Instruction
|
Published
|
06/06/2022 9:38 PM
|
4382 - Record information on the Handheld Radiation Monitor Assessment Form... | Remark
|
Published
|
06/06/2022 9:38 PM
|
4381 - 319 - Perform operational test; Remark:4380 | Procedure Step
|
Published
|
06/06/2022 9:40 PM
|
319 - Perform operational test | Instruction
|
Published
|
06/10/2021 8:31 PM
|
4380 - DET-HHD-STE-HRM-RM01, Handheld Radiation Monitor Operational Test. | Remark
|
Published
|
06/06/2022 9:40 PM
|
4379 - 4378 - Replace battery; Remark:4377 | Procedure Step
|
Published
|
06/06/2022 9:42 PM
|
4378 - Replace battery | Instruction
|
Published
|
06/06/2022 9:41 PM
|
4377 - DET-HHD-STE-HRM-RM02, Handheld Radiation Monitor Battery Replacement... | Remark
|
Published
|
06/06/2022 9:42 PM
|
4376 - 346 - Submit assessment form; Remark:4375 | Procedure Step
|
Published
|
06/06/2022 9:43 PM
|
346 - Submit assessment form | Instruction
|
Published
|
06/16/2021 10:39 PM
|
4375 - Submit Handheld Radiation Monitor Assessment Form or HATS [Handheld ... | Remark
|
Published
|
06/06/2022 9:43 PM
|
Routine Maintenance Procedure | Document Type
|
Published
|
03/02/2020 3:31 PM
|
minutes | Duration
|
Published
|
05/26/2022 11:41 AM
|
Annually | Frequency
|
Published
|
04/01/2020 11:37 AM
|
Technician 1 | Skill Level
|
Published
|
05/14/2020 2:56 PM
|
None | Tools
|
Published
|
05/06/2020 9:50 PM
|
HRM Serial Number Location | Image
|
Published
|
08/02/2022 7:55 PM
|
HRM Assessment Form for RM03 | File
|
Published
|
08/03/2022 10:47 AM
|
Handheld Radiation Monitor Operational Test
Last Updated: 05/07/2025 1:40 AM
The following table lists all the components that make up the document.
PackEye Backup Battery
Last Updated: 05/07/2025 1:39 AM
The following table lists all the components that make up the document.