MDS PORTAL Mode Operation

Last Updated: 04/26/2025 1:40 AM

The following table lists all the components that make up the document.

Title Type Status Last Updated
Rapiscan MD-134C
Device
Published
10/28/2024 3:39 PM
1402 - 7927 - Establish Initial Conditions; Remark:
Procedure Step
Published
09/30/2022 1:47 PM
7927 - Establish Initial Conditions
Instruction
Published
07/12/2023 12:23 AM
5143 - 5043 - Verify MDS van has fuel; Remark:
Procedure Step
Published
09/30/2022 3:16 PM
5043 - Verify MDS van has fuel
Instruction
Published
09/30/2022 1:49 PM
5144 - 5044 - Verify handheld radiation detection batteries are charged; Remark:
Procedure Step
Published
09/30/2022 3:17 PM
5044 - Verify handheld radiation detection batteries are charged
Instruction
Published
09/30/2022 1:50 PM
5145 - 5045 - Verify at least two MDS operators and a support team are present; Remark:
Procedure Step
Published
09/30/2022 3:17 PM
5045 - Verify at least two MDS operators and a support team are present
Instruction
Published
09/30/2022 1:51 PM
5234 - 5233 - Power on System; Remark:
Procedure Step
Published
10/05/2022 5:46 PM
5233 - Power on System
Instruction
Published
10/05/2022 5:45 PM
5134 - 5049 - Turn mode control switch (MCS) to PORTAL mode; Remark:5085
Procedure Step
Published
10/05/2022 9:26 AM
5049 - Turn mode control switch (MCS) to PORTAL mode
Instruction
Published
09/30/2022 4:32 PM
5085 - IO MCS in Portal Mode Full Switch Image
Remark
Published
09/30/2022 11:33 AM
5231 - 5050 - Verify occupancy sensor is not blocked or occupied; Remark:5090
Procedure Step
Published
10/05/2022 9:29 AM
5050 - Verify occupancy sensor is not blocked or occupied
Instruction
Published
10/05/2022 8:14 AM
5090 - No objects should be within 5 meters of the occupancy sensor.
Remark
Published
10/05/2022 8:15 AM
5135 - 5051 - Place both breaker switches in UP position to power on system; Remark:5086
Procedure Step
Published
09/30/2022 3:20 PM
5051 - Place both breaker switches in UP position to power on system
Instruction
Published
09/30/2022 1:55 PM
5086 - IO MDS Power Breakers Up and On
Remark
Published
09/30/2022 11:34 AM
5136 - 5052 - Verify SC-770 controller module indicates “OK” after power on self-test; Remark:5087
Procedure Step
Published
09/30/2022 3:20 PM
5052 - Verify SC-770 controller module indicates “OK” after power on self-test
Instruction
Published
09/30/2022 1:56 PM
5087 - IO RPM SC-770 shows OK for status
Remark
Published
09/30/2022 11:35 AM
5137 - 5053 - Observe skid battery voltage is above 12 Volts; Remark:5088
Procedure Step
Published
09/30/2022 3:20 PM
5053 - Observe skid battery voltage is above 12 Volts
Instruction
Published
09/30/2022 1:57 PM
5088 - IO MDS Skid Battery 12.7 V
Remark
Published
09/30/2022 11:36 AM
5138 - 5054 - Power on RAVEN laptop; Remark:5058
Procedure Step
Published
09/30/2022 3:34 PM
5054 - Power on RAVEN laptop
Instruction
Published
09/30/2022 1:58 PM
5058 - RAVEN should start automatically
Remark
Published
09/30/2022 2:09 PM
5139 - 5055 - Log in to RAVEN software; Remark:5089
Procedure Step
Published
09/30/2022 3:21 PM
5055 - Log in to RAVEN software
Instruction
Published
09/30/2022 1:58 PM
5089 - IO RAVEN Log-In Screen "test"
Remark
Published
09/30/2022 11:38 AM
5140 - 5056 - Check RAVEN status health; Remark:5059
Procedure Step
Published
09/30/2022 3:21 PM
5056 - Check RAVEN status health
Instruction
Published
09/30/2022 1:59 PM
5059 - Status tab should have all green indications.
Remark
Published
09/30/2022 3:35 PM
5060 - Real-time viewer should be functioning properly. The View Live Imag...
Remark
Published
09/30/2022 2:11 PM
5232 - 5046 - Check camera alignment; Remark:5091
Procedure Step
Published
10/05/2022 5:47 PM
5046 - Check camera alignment
Instruction
Published
09/30/2022 1:53 PM
5091 - IO MDS Camera Alignment Portal Mode
Remark
Published
09/30/2022 11:44 AM
5237 - 5092 - Set Up MDS Van for Portal Mode Operation; Remark:
Procedure Step
Published
10/05/2022 5:50 PM
5092 - Set Up MDS Van for Portal Mode Operation
Instruction
Published
10/05/2022 8:17 AM
5236 - 5093 - Drive van to area of operations; Remark:5094
Procedure Step
Published
10/05/2022 5:55 PM
5132 - Note : When driving to area of operations you may shut down the system and drive, or...
Annotation
Published
10/05/2022 5:56 PM
5093 - Drive van to area of operations
Instruction
Published
10/03/2022 2:45 PM
5094 - Make sure the equipment is secured and ready for movement.
Remark
Published
10/03/2022 2:46 PM
5238 - 5095 - Park MDS van in area of operations; Remark:
Procedure Step
Published
10/05/2022 5:54 PM
5095 - Park MDS van in area of operations
Instruction
Published
10/03/2022 2:47 PM
5239 - 5096 - Set up traffic cones 1 and 5 meters from van to create traffic lane; Remark:5160
Procedure Step
Published
10/05/2022 5:54 PM
5096 - Set up traffic cones 1 and 5 meters from van to create traffic lane
Instruction
Published
10/03/2022 2:48 PM
5160 - IO MDS Parked Roadside
Remark
Published
09/30/2022 3:45 PM
5240 - 5097 - Attach external alarm box; Remark:5161
Procedure Step
Published
10/05/2022 5:53 PM
5097 - Attach external alarm box
Instruction
Published
10/03/2022 2:49 PM
5161 - IO MDS External Alarm Box on Van
Remark
Published
09/30/2022 3:46 PM
5241 - 5098 - Check occupancy sensor and camera alignment; Remark:5099
Procedure Step
Published
10/05/2022 5:53 PM
5098 - Check occupancy sensor and camera alignment
Instruction
Published
10/03/2022 2:49 PM
5099 - It is good practice to drive a test car by the MDS van to verify occupancy se...
Remark
Published
10/03/2022 2:50 PM
5242 - 5100 - Set up 5 kph speed sign; Remark:5168
Procedure Step
Published
04/13/2025 6:18 PM
5100 - Set up 5 kph speed sign
Instruction
Published
04/13/2025 5:35 PM
5168 - IO MDS Roadside 5 kph Sign
Remark
Published
09/30/2022 3:48 PM
5243 - 5102 - Position police chase vehicle in vicinity of MDS van; Remark:
Procedure Step
Published
10/05/2022 5:52 PM
5102 - Position police chase vehicle in vicinity of MDS van
Instruction
Published
10/03/2022 2:52 PM
5244 - 5103 - Establish secondary inspection zone; Remark:
Procedure Step
Published
10/05/2022 5:51 PM
5103 - Establish secondary inspection zone
Instruction
Published
10/03/2022 2:53 PM
5258 - 5105 - Conduct PORTAL Mode Operation; Remark:
Procedure Step
Published
10/05/2022 5:49 PM
5105 - Conduct PORTAL Mode Operation
Instruction
Published
10/03/2022 2:54 PM
5256 - 5107 - Direct vehicles through traffic lane; Remark:
Procedure Step
Published
10/05/2022 5:50 PM
5107 - Direct vehicles through traffic lane
Instruction
Published
10/03/2022 2:54 PM
5257 - 5109 - Respond to alarms; Remark:5260
Procedure Step
Published
10/05/2022 5:50 PM
5109 - Respond to alarms
Instruction
Published
10/03/2022 2:55 PM
5260 - RAVEN Camera White Truck Gamma Alarm
Remark
Published
10/05/2022 8:27 AM
5167 - 5111 - Perform secondary inspection following an alarm; Remark:5262
Procedure Step
Published
09/30/2022 3:49 PM
5111 - Perform secondary inspection following an alarm
Instruction
Published
09/30/2022 2:30 PM
5262 - IO RAVEN Real Time Viewer Gamma Alarm 2750 Graph
Remark
Published
10/05/2022 11:04 AM
5150 - 5062 - Conduct Secondary Inspection; Remark:
Procedure Step
Published
09/30/2022 3:26 PM
5062 - Conduct Secondary Inspection
Instruction
Published
09/30/2022 3:55 PM
5245 - 5063 - Establish secondary inspection team; Remark:
Procedure Step
Published
10/05/2022 3:53 PM
5063 - Establish secondary inspection team
Instruction
Published
09/30/2022 4:10 PM
5246 - 5065 - Receive radiation profile information from CAS operator; Remark:5066
Procedure Step
Published
10/05/2022 3:56 PM
5065 - Receive radiation profile information from CAS operator
Instruction
Published
09/30/2022 4:12 PM
5066 - Radiation profile should include type of alarm (neutron or gamma) and approxi...
Remark
Published
09/30/2022 4:18 PM
5247 - 5067 - Isolate vehicle and separate driver and passengers from vehicle; Remark:
Procedure Step
Published
04/13/2025 6:18 PM
5067 - Isolate vehicle and separate driver and passengers from vehicle
Instruction
Published
04/13/2025 5:35 PM
5248 - 5068 - Perform initial radiological hazard assessment; Remark:5069
Procedure Step
Published
10/05/2022 3:59 PM
5068 - Perform initial radiological hazard assessment
Instruction
Published
09/30/2022 4:20 PM
5069 - Walk around vehicle using personal radiation detector to establish a safety z...
Remark
Published
09/30/2022 4:21 PM
5249 - 5070 - Use survey instrument to localize radiation source; Remark:5071
Procedure Step
Published
10/05/2022 4:01 PM
5070 - Use survey instrument to localize radiation source
Instruction
Published
09/30/2022 4:22 PM
5071 - Inspect vehicle, driver and passengers.
Remark
Published
09/30/2022 4:23 PM
5250 - 5072 - Mark hot spot(s) with marking symbol; Remark:3332
Procedure Step
Published
04/13/2025 6:18 PM
5072 - Mark hot spot(s) with marking symbol
Instruction
Published
04/13/2025 5:35 PM
3332 - IO - Mark location of alarming radiation levels Truck
Remark
Published
05/15/2023 10:22 AM
5251 - 5073 - Use radioisotope identification device (RID) to identify isotope; Remark:
Procedure Step
Published
10/05/2022 4:04 PM
5073 - Use radioisotope identification device (RID) to identify isotope
Instruction
Published
09/30/2022 4:26 PM
5252 - 5074 - Compare isotope to driver paperwork; Remark:
Procedure Step
Published
10/05/2022 4:05 PM
5074 - Compare isotope to driver paperwork
Instruction
Published
09/30/2022 4:27 PM
5253 - 5075 - Make interdiction decision; Remark:
Procedure Step
Published
10/05/2022 4:06 PM
5075 - Make interdiction decision
Instruction
Published
09/30/2022 4:28 PM
5254 - 5076 - Record information; Remark:
Procedure Step
Published
10/05/2022 4:07 PM
5076 - Record information
Instruction
Published
09/30/2022 4:29 PM
5255 - 5077 - Upload RID spectra to RAVEN laptop; Remark:5078
Procedure Step
Published
10/05/2022 4:08 PM
5077 - Upload RID spectra to RAVEN laptop
Instruction
Published
09/30/2022 4:30 PM
5078 - Refer to applicable Upload and Attach procedure.
Remark
Published
09/30/2022 4:31 PM
5149 - 5079 - Power Off MDS; Remark:
Procedure Step
Published
09/30/2022 3:26 PM
5079 - Power Off MDS
Instruction
Published
10/05/2022 7:58 AM
5227 - 5080 - Power off RAVEN laptop; Remark:
Procedure Step
Published
10/03/2022 3:56 PM
5080 - Power off RAVEN laptop
Instruction
Published
09/30/2022 4:33 PM
5228 - 5081 - Place both breaker switches in DOWN position to power off system.; Remark:5159
Procedure Step
Published
10/03/2022 3:56 PM
5081 - Place both breaker switches in DOWN position to power off system.
Instruction
Published
09/30/2022 4:42 PM
5159 - IO MDS Power Breakers Off
Remark
Published
10/03/2022 1:57 PM
5229 - 5082 - Secure all equipment; Remark:5083
Procedure Step
Published
10/03/2022 3:55 PM
5082 - Secure all equipment
Instruction
Published
09/30/2022 4:35 PM
5083 - Such as the external alarm box and storage drawer.
Remark
Published
09/30/2022 4:36 PM
5230 - 5084 - Recharge handheld radiation detection equipment; Remark:
Procedure Step
Published
10/03/2022 3:54 PM
5084 - Recharge handheld radiation detection equipment
Instruction
Published
09/30/2022 4:37 PM
Operator Procedure
Document Type
Published
03/02/2020 3:31 PM
Note
Annotation Type
Published
03/02/2020 3:25 PM
MDS Mode Portal Full MCS
Image
Published
09/30/2022 9:51 AM
MDS Radar Occupancy Sensor
Image
Published
09/30/2022 9:48 AM
MDS Power Breakers On
Image
Published
09/30/2022 10:59 AM
RPM POST OK SC-770
Image
Published
09/29/2022 6:28 PM
MDS Skid Battery 12.7V
Image
Published
09/30/2022 11:03 AM
RAVEN Starting App Screen
Image
Published
09/29/2022 6:31 PM
RAVEN Log In Screen
Image
Published
09/29/2022 6:34 PM
RAVEN State of Health Screen All Green
Image
Published
09/29/2022 6:36 PM
MDS Camera Alignment In-Motion Sketch1
Image
Published
09/30/2022 10:56 AM
MDS Parked Roadside
Image
Published
09/30/2022 9:46 AM
MDS External Alarm Box on Van
Image
Published
09/30/2022 10:53 AM
MDS Roadside 5 kph Sign
Image
Published
09/30/2022 11:06 AM
RAVEN Camera White Truck Gamma Alarm
Image
Published
09/29/2022 6:40 PM
RAVEN Real Time Viewer Gamma Alarm 2750 Graph
Image
Published
09/29/2022 6:53 PM
Mark Source Truck Side Trefoil
Image
Published
05/01/2021 2:01 AM
MDS Power Breakers Off
Image
Published
09/30/2022 11:01 AM

MDS Scan and Survey Mode Operation

Last Updated: 04/26/2025 1:40 AM

The following table lists all the components that make up the document.

Title Type Status Last Updated
Rapiscan MD-134C
Device
Published
10/28/2024 3:39 PM
1402 - 7927 - Establish Initial Conditions; Remark:
Procedure Step
Published
09/30/2022 1:47 PM
7927 - Establish Initial Conditions
Instruction
Published
07/12/2023 12:23 AM
5143 - 5043 - Verify MDS van has fuel; Remark:
Procedure Step
Published
09/30/2022 3:16 PM
5043 - Verify MDS van has fuel
Instruction
Published
09/30/2022 1:49 PM
5144 - 5044 - Verify handheld radiation detection batteries are charged; Remark:
Procedure Step
Published
09/30/2022 3:17 PM
5044 - Verify handheld radiation detection batteries are charged
Instruction
Published
09/30/2022 1:50 PM
5145 - 5045 - Verify at least two MDS operators and a support team are present; Remark:
Procedure Step
Published
09/30/2022 3:17 PM
5045 - Verify at least two MDS operators and a support team are present
Instruction
Published
09/30/2022 1:51 PM
5146 - 5061 - Arrange laptop and mode control switch (MCS) for front seat operation; Remark:
Procedure Step
Published
09/30/2022 3:18 PM
5061 - Arrange laptop and mode control switch (MCS) for front seat operation
Instruction
Published
09/30/2022 1:52 PM
5147 - 5046 - Check camera alignment; Remark:5047
Procedure Step
Published
09/30/2022 3:18 PM
5046 - Check camera alignment
Instruction
Published
09/30/2022 1:53 PM
5047 - In general, for in-motion operations; one camera is pointed perpendicular to ...
Remark
Published
09/30/2022 1:53 PM
5142 - 5048 - Prepare for Scan and Survey; Remark:
Procedure Step
Published
09/30/2022 3:19 PM
5048 - Prepare for Scan and Survey
Instruction
Published
09/30/2022 1:54 PM
5134 - 5049 - Turn mode control switch (MCS) to PORTAL mode; Remark:5085
Procedure Step
Published
10/05/2022 9:26 AM
5049 - Turn mode control switch (MCS) to PORTAL mode
Instruction
Published
09/30/2022 4:32 PM
5085 - IO MCS in Portal Mode Full Switch Image
Remark
Published
09/30/2022 11:33 AM
5135 - 5051 - Place both breaker switches in UP position to power on system; Remark:5086
Procedure Step
Published
09/30/2022 3:20 PM
5051 - Place both breaker switches in UP position to power on system
Instruction
Published
09/30/2022 1:55 PM
5086 - IO MDS Power Breakers Up and On
Remark
Published
09/30/2022 11:34 AM
5136 - 5052 - Verify SC-770 controller module indicates “OK” after power on self-test; Remark:5087
Procedure Step
Published
09/30/2022 3:20 PM
5052 - Verify SC-770 controller module indicates “OK” after power on self-test
Instruction
Published
09/30/2022 1:56 PM
5087 - IO RPM SC-770 shows OK for status
Remark
Published
09/30/2022 11:35 AM
5137 - 5053 - Observe skid battery voltage is above 12 Volts; Remark:5088
Procedure Step
Published
09/30/2022 3:20 PM
5053 - Observe skid battery voltage is above 12 Volts
Instruction
Published
09/30/2022 1:57 PM
5088 - IO MDS Skid Battery 12.7 V
Remark
Published
09/30/2022 11:36 AM
5138 - 5054 - Power on RAVEN laptop; Remark:5058
Procedure Step
Published
09/30/2022 3:34 PM
5054 - Power on RAVEN laptop
Instruction
Published
09/30/2022 1:58 PM
5058 - RAVEN should start automatically
Remark
Published
09/30/2022 2:09 PM
5139 - 5055 - Log in to RAVEN software; Remark:5089
Procedure Step
Published
09/30/2022 3:21 PM
5055 - Log in to RAVEN software
Instruction
Published
09/30/2022 1:58 PM
5089 - IO RAVEN Log-In Screen "test"
Remark
Published
09/30/2022 11:38 AM
5140 - 5056 - Check RAVEN status health; Remark:5059
Procedure Step
Published
09/30/2022 3:21 PM
5056 - Check RAVEN status health
Instruction
Published
09/30/2022 1:59 PM
5059 - Status tab should have all green indications.
Remark
Published
09/30/2022 3:35 PM
5060 - Real-time viewer should be functioning properly. The View Live Imag...
Remark
Published
09/30/2022 2:11 PM
5141 - 5057 - Secure equipment for driving; Remark:
Procedure Step
Published
09/30/2022 3:22 PM
5057 - Secure equipment for driving
Instruction
Published
09/30/2022 2:00 PM
5152 - 5101 - Conduct SURVEY Mode Operation; Remark:
Procedure Step
Published
09/30/2022 3:23 PM
5101 - Conduct SURVEY Mode Operation
Instruction
Published
09/30/2022 2:18 PM
5154 - 5104 - Drive van to area of operation for preliminary survey; Remark:5119
Procedure Step
Published
09/30/2022 3:23 PM
5104 - Drive van to area of operation for preliminary survey
Instruction
Published
09/30/2022 2:18 PM
5119 - IO MDS Survey Mode Parking Lot
Remark
Published
09/30/2022 12:04 PM
5155 - 5106 - Turn MCS to SURVEY; Remark:5120
Procedure Step
Published
09/30/2022 3:52 PM
5106 - Turn MCS to SURVEY
Instruction
Published
09/30/2022 2:19 PM
5120 - IO MDS MCS in Survey Mode
Remark
Published
09/30/2022 12:06 PM
5156 - 5108 - Open RAVEN real-time viewer tab; Remark:5121
Procedure Step
Published
09/30/2022 3:24 PM
5108 - Open RAVEN real-time viewer tab
Instruction
Published
09/30/2022 2:20 PM
5121 - IO RAVEN Real Time Gamma 2308
Remark
Published
09/30/2022 12:07 PM
5157 - 5110 - Move through desired survey area; Remark:5122
Procedure Step
Published
09/30/2022 3:24 PM
5110 - Move through desired survey area
Instruction
Published
09/30/2022 2:21 PM
5122 - Maintain a low speed (8 kilometers per hour [kph]).
Remark
Published
09/30/2022 2:22 PM
5158 - 5153 - Use real-time viewer to locate elevated radiation counts; Remark:
Procedure Step
Published
09/30/2022 3:25 PM
5153 - Use real-time viewer to locate elevated radiation counts
Instruction
Published
09/30/2022 3:05 PM
5151 - 5113 - Conduct SCAN Mode Operation; Remark:
Procedure Step
Published
09/30/2022 3:25 PM
5113 - Conduct SCAN Mode Operation
Instruction
Published
09/30/2022 2:23 PM
5162 - 5093 - Drive van to area of operations; Remark:5123
Procedure Step
Published
09/30/2022 3:51 PM
5131 - Note : Conduct short, targeted scans and collect frequent backgrounds.
Annotation
Published
09/30/2022 2:25 PM
5093 - Drive van to area of operations
Instruction
Published
10/03/2022 2:45 PM
5123 - IO MDS Scan Mode Parking Lot
Remark
Published
09/30/2022 12:09 PM
5163 - 5114 - Turn MCS to BKGRND position once approximately 10 meters from target; Remark:5124
Procedure Step
Published
09/30/2022 3:51 PM
5114 - Turn MCS to BKGRND position once approximately 10 meters from target
Instruction
Published
09/30/2022 2:25 PM
5124 - IO MDS MCS in BKGRND Mode
Remark
Published
09/30/2022 12:10 PM
5164 - 5115 - Gather background information; Remark:5125
Procedure Step
Published
09/30/2022 3:50 PM
5115 - Gather background information
Instruction
Published
09/30/2022 2:26 PM
5125 - Dwell time is approximately 20 to 30 seconds. Wait for the red and black line...
Remark
Published
10/05/2022 3:41 PM
5165 - 5116 - Turn MCS to SCAN mode; Remark:5126
Procedure Step
Published
09/30/2022 3:50 PM
5130 - Note : If there is an alarm immediately after switching from BKGRND to SCAN, it may ...
Annotation
Published
09/30/2022 2:36 PM
5116 - Turn MCS to SCAN mode
Instruction
Published
09/30/2022 2:28 PM
5126 - IO MDS MCS in Scan Mode
Remark
Published
09/30/2022 12:12 PM
5166 - 5117 - Drive past target; Remark:5128
Procedure Step
Published
09/30/2022 3:49 PM
5117 - Drive past target
Instruction
Published
09/30/2022 2:29 PM
5128 -
Remark
Published
09/30/2022 2:31 PM
5127 - Maintain a low speed (8 kph) and close proximity to the target.
Remark
Published
09/30/2022 2:32 PM
5264 - 5118 - Turn MCS to BKGRND position; Remark:5263
Procedure Step
Published
10/05/2022 4:16 PM
5118 - Turn MCS to BKGRND position
Instruction
Published
09/30/2022 2:30 PM
5263 - This ends the scan.
Remark
Published
10/05/2022 4:18 PM
5167 - 5111 - Perform secondary inspection following an alarm; Remark:5262
Procedure Step
Published
09/30/2022 3:49 PM
5111 - Perform secondary inspection following an alarm
Instruction
Published
09/30/2022 2:30 PM
5262 - IO RAVEN Real Time Viewer Gamma Alarm 2750 Graph
Remark
Published
10/05/2022 11:04 AM
5150 - 5062 - Conduct Secondary Inspection; Remark:
Procedure Step
Published
09/30/2022 3:26 PM
5062 - Conduct Secondary Inspection
Instruction
Published
09/30/2022 3:55 PM
5245 - 5063 - Establish secondary inspection team; Remark:
Procedure Step
Published
10/05/2022 3:53 PM
5063 - Establish secondary inspection team
Instruction
Published
09/30/2022 4:10 PM
5246 - 5065 - Receive radiation profile information from CAS operator; Remark:5066
Procedure Step
Published
10/05/2022 3:56 PM
5065 - Receive radiation profile information from CAS operator
Instruction
Published
09/30/2022 4:12 PM
5066 - Radiation profile should include type of alarm (neutron or gamma) and approxi...
Remark
Published
09/30/2022 4:18 PM
5247 - 5067 - Isolate vehicle and separate driver and passengers from vehicle; Remark:
Procedure Step
Published
04/13/2025 6:18 PM
5067 - Isolate vehicle and separate driver and passengers from vehicle
Instruction
Published
04/13/2025 5:35 PM
5248 - 5068 - Perform initial radiological hazard assessment; Remark:5069
Procedure Step
Published
10/05/2022 3:59 PM
5068 - Perform initial radiological hazard assessment
Instruction
Published
09/30/2022 4:20 PM
5069 - Walk around vehicle using personal radiation detector to establish a safety z...
Remark
Published
09/30/2022 4:21 PM
5249 - 5070 - Use survey instrument to localize radiation source; Remark:5071
Procedure Step
Published
10/05/2022 4:01 PM
5070 - Use survey instrument to localize radiation source
Instruction
Published
09/30/2022 4:22 PM
5071 - Inspect vehicle, driver and passengers.
Remark
Published
09/30/2022 4:23 PM
5250 - 5072 - Mark hot spot(s) with marking symbol; Remark:3332
Procedure Step
Published
04/13/2025 6:18 PM
5072 - Mark hot spot(s) with marking symbol
Instruction
Published
04/13/2025 5:35 PM
3332 - IO - Mark location of alarming radiation levels Truck
Remark
Published
05/15/2023 10:22 AM
5251 - 5073 - Use radioisotope identification device (RID) to identify isotope; Remark:
Procedure Step
Published
10/05/2022 4:04 PM
5073 - Use radioisotope identification device (RID) to identify isotope
Instruction
Published
09/30/2022 4:26 PM
5252 - 5074 - Compare isotope to driver paperwork; Remark:
Procedure Step
Published
10/05/2022 4:05 PM
5074 - Compare isotope to driver paperwork
Instruction
Published
09/30/2022 4:27 PM
5253 - 5075 - Make interdiction decision; Remark:
Procedure Step
Published
10/05/2022 4:06 PM
5075 - Make interdiction decision
Instruction
Published
09/30/2022 4:28 PM
5254 - 5076 - Record information; Remark:
Procedure Step
Published
10/05/2022 4:07 PM
5076 - Record information
Instruction
Published
09/30/2022 4:29 PM
5255 - 5077 - Upload RID spectra to RAVEN laptop; Remark:5078
Procedure Step
Published
10/05/2022 4:08 PM
5077 - Upload RID spectra to RAVEN laptop
Instruction
Published
09/30/2022 4:30 PM
5078 - Refer to applicable Upload and Attach procedure.
Remark
Published
09/30/2022 4:31 PM
5149 - 5079 - Power Off MDS; Remark:
Procedure Step
Published
09/30/2022 3:26 PM
5079 - Power Off MDS
Instruction
Published
10/05/2022 7:58 AM
5226 - 5225 - Turn MCS to PORTAL mode; Remark:5064
Procedure Step
Published
10/05/2022 4:10 PM
5225 - Turn MCS to PORTAL mode
Instruction
Published
10/05/2022 4:23 PM
5064 - IO MCS in Portal Mode
Remark
Published
09/30/2022 10:24 AM
5227 - 5080 - Power off RAVEN laptop; Remark:
Procedure Step
Published
10/03/2022 3:56 PM
5080 - Power off RAVEN laptop
Instruction
Published
09/30/2022 4:33 PM
5228 - 5081 - Place both breaker switches in DOWN position to power off system.; Remark:5159
Procedure Step
Published
10/03/2022 3:56 PM
5081 - Place both breaker switches in DOWN position to power off system.
Instruction
Published
09/30/2022 4:42 PM
5159 - IO MDS Power Breakers Off
Remark
Published
10/03/2022 1:57 PM
5229 - 5082 - Secure all equipment; Remark:5083
Procedure Step
Published
10/03/2022 3:55 PM
5082 - Secure all equipment
Instruction
Published
09/30/2022 4:35 PM
5083 - Such as the external alarm box and storage drawer.
Remark
Published
09/30/2022 4:36 PM
5230 - 5084 - Recharge handheld radiation detection equipment; Remark:
Procedure Step
Published
10/03/2022 3:54 PM
5084 - Recharge handheld radiation detection equipment
Instruction
Published
09/30/2022 4:37 PM
Operator Procedure
Document Type
Published
03/02/2020 3:31 PM
Note
Annotation Type
Published
03/02/2020 3:25 PM
MDS Camera Alignment In-Motion Sketch1
Image
Published
09/30/2022 10:56 AM
MDS Mode Portal Full MCS
Image
Published
09/30/2022 9:51 AM
MDS Power Breakers On
Image
Published
09/30/2022 10:59 AM
RPM POST OK SC-770
Image
Published
09/29/2022 6:28 PM
MDS Skid Battery 12.7V
Image
Published
09/30/2022 11:03 AM
RAVEN Starting App Screen
Image
Published
09/29/2022 6:31 PM
RAVEN Log In Screen
Image
Published
09/29/2022 6:34 PM
RAVEN State of Health Screen All Green
Image
Published
09/29/2022 6:36 PM
MDS Parking Lot Survey Mode
Image
Published
09/30/2022 9:41 AM
MDS Mode Survey Half MCS
Image
Published
09/30/2022 9:54 AM
RAVEN Real Time Viewer Gamma 2308
Image
Published
09/29/2022 6:45 PM
MDS Parking Lot Scan Mode
Image
Published
09/30/2022 9:43 AM
MDS Mode Background Half MCS
Image
Published
09/30/2022 9:56 AM
RAVEN Real Time Viewer Background 4679
Image
Published
09/29/2022 6:50 PM
MDS Mode Scan Half MCS
Image
Published
09/30/2022 9:57 AM
RAVEN Real Time Viewer Gamma Alarm 2750 Graph
Image
Published
09/29/2022 6:53 PM
Mark Source Truck Side Trefoil
Image
Published
05/01/2021 2:01 AM
MDS Mode Portal Half MCS
Image
Published
10/12/2022 12:24 PM
MDS Power Breakers Off
Image
Published
09/30/2022 11:01 AM

PackEye Trimble Pairing

Last Updated: 04/26/2025 1:39 AM

The following table lists all the components that make up the document.

Title Type Status Last Updated
Thermo FHT1377 PackEye
Device
Published
10/28/2024 3:37 PM
3923 - 3874 - Check Equipment; Remark:
Procedure Step
Published
04/05/2022 2:22 PM
3874 - Check Equipment
Instruction
Published
04/04/2022 3:12 PM
3869 - 313 - Power off instrument; Remark:3850
Procedure Step
Published
03/29/2022 2:23 AM
313 - Power off instrument
Instruction
Published
07/23/2021 2:41 PM
3850 - Press and hold the power button for approximately 10 seconds until indicator ...
Remark
Published
03/29/2022 1:38 AM
3926 - 3876 - Open top of backpack; Remark:3928
Procedure Step
Published
04/05/2022 5:28 PM
3876 - Open top of backpack
Instruction
Published
04/04/2022 3:14 PM
3928 - IO PackEye Open Top of Backpack for Battery Access
Remark
Published
10/24/2024 6:52 PM
4178 - 3877 - Verify connections; Remark:3900
Procedure Step
Published
05/10/2022 11:17 AM
4132 - Caution : Do not plug RS232 interconnect cable into lower connectors on the FHT 681 amp...
Annotation
Published
05/03/2022 4:16 PM
3877 - Verify connections
Instruction
Published
04/04/2022 3:14 PM
3900 - The RS232 interconnect cable from the power module should be connected to the...
Remark
Published
04/06/2022 2:17 PM
3930 - 3878 - Verify RS232 BT adapter and cable are connected; Remark:3901
Procedure Step
Published
04/06/2022 8:37 AM
3878 - Verify RS232 BT adapter and cable are connected
Instruction
Published
04/04/2022 3:15 PM
3901 - The RS232 BT adapter cable connects to the power supply module.
Remark
Published
04/06/2022 2:19 PM
4190 - 4179 - Verify BT adapter is correct; Remark:4164
Procedure Step
Published
05/10/2022 1:41 PM
3894 - Note : Several BT Adapters have been deployed with the PackEye for wireless operatio...
Annotation
Published
04/04/2022 4:34 PM
4179 - Verify BT adapter is correct
Instruction
Published
05/10/2022 1:28 PM
4164 - The Trimble only communicates with the LM Technologies LM048 BT adapter. ...
Remark
Published
05/06/2022 3:35 PM
4191 - 4180 - Verify BT adapter is in DTE mode; Remark:4165
Procedure Step
Published
05/10/2022 1:42 PM
4133 - Caution : Do not push Reset button. This will reprogram the BT adapter...
Annotation
Published
05/03/2022 4:19 PM
4180 - Verify BT adapter is in DTE mode
Instruction
Published
05/18/2022 1:49 PM
4165 - The switch might be covered with a sticker or label. If so, the switch should...
Remark
Published
05/06/2022 3:37 PM
4195 - 3882 - Document BT adapter serial number; Remark:4166
Procedure Step
Published
05/10/2022 1:43 PM
3882 - Document BT adapter serial number
Instruction
Published
04/04/2022 3:24 PM
4166 - The serial number is located on the bottom of the BT adapter.
Remark
Published
05/06/2022 3:38 PM
3925 - 3883 - Power on Equipment; Remark:
Procedure Step
Published
04/05/2022 2:30 PM
3896 - Note : It is best practice to only have one PackEye powered on at a time to minimize...
Annotation
Published
04/04/2022 4:36 PM
3883 - Power on Equipment
Instruction
Published
04/04/2022 3:25 PM
3852 - 220 - Power on instrument; Remark:3836
Procedure Step
Published
03/29/2022 1:59 AM
220 - Power on instrument
Instruction
Published
04/06/2025 7:00 PM
3836 - Press power button on the indicator unit for approximately 1 second.
Remark
Published
03/29/2022 1:05 AM
4196 - 3884 - Verify BT adapter lights are active; Remark:4167
Procedure Step
Published
05/10/2022 1:44 PM
3884 - Verify BT adapter lights are active
Instruction
Published
04/04/2022 3:26 PM
4167 - There will be a solid red power light and a flashing blue (Bluetooth) light.
Remark
Published
05/06/2022 3:41 PM
4197 - 1495 - Power on mobile device; Remark:4060
Procedure Step
Published
04/07/2025 1:51 PM
1495 - Power on mobile device
Instruction
Published
11/12/2020 4:20 PM
4060 - The display may take 2 to 3 seconds to appear.
Remark
Published
05/13/2022 11:40 AM
4061 - The PackEye software should start automatically. If it does not, use the styl...
Remark
Published
05/03/2022 11:23 AM
4096 - 4051 - Tap ok on popup message; Remark:4126
Procedure Step
Published
05/03/2022 11:27 AM
4051 - Tap ok on popup message
Instruction
Published
05/02/2022 10:25 AM
4126 - IO PackEye OK to proceed
Remark
Published
11/16/2024 8:52 PM
4127 - 3887 - Pair with BT Adapter; Remark:
Procedure Step
Published
05/03/2022 3:02 PM
3887 - Pair with BT Adapter
Instruction
Published
04/04/2022 3:28 PM
4205 - 4181 - Navigate to S1 tab; Remark:4168
Procedure Step
Published
05/10/2022 1:50 PM
4181 - Navigate to S1 tab
Instruction
Published
05/18/2022 1:48 PM
4168 - Use stylus to tap the right arrow. Select S1
Remark
Published
05/06/2022 3:43 PM
4206 - 4182 - Tap Search BT Devices; Remark:4169
Procedure Step
Published
05/10/2022 1:51 PM
4182 - Tap Search BT Devices
Instruction
Published
05/18/2022 1:47 PM
4169 - IO PackEye Trimble Search BT Devices Button
Remark
Published
05/06/2022 3:45 PM
4208 - 3889 - Select BT adapter; Remark:4170
Procedure Step
Published
05/10/2022 1:53 PM
4134 - Note : If multiple PackEye units with BT adapters are nearby, they might appear in t...
Annotation
Published
05/03/2022 4:22 PM
3889 - Select BT adapter
Instruction
Published
04/04/2022 3:30 PM
4170 - Tap dropdown arrow. Tap on BT Adapter serial number located earlier.
Remark
Published
05/06/2022 3:46 PM
4209 - 4183 - Verify successful selection; Remark:4171
Procedure Step
Published
05/10/2022 1:54 PM
4183 - Verify successful selection
Instruction
Published
05/10/2022 1:31 PM
4171 - The dropdown box will have blue shading.
Remark
Published
05/06/2022 3:47 PM
4210 - 4184 - Verify FHT681 active is checked; Remark:4172
Procedure Step
Published
05/10/2022 1:55 PM
4184 - Verify FHT681 active is checked
Instruction
Published
05/18/2022 1:47 PM
4172 - IO PackEye Trimble FHT681 Active Setting
Remark
Published
05/06/2022 3:49 PM
4211 - 4185 - Verify GPS active is checked; Remark:4173
Procedure Step
Published
05/10/2022 1:56 PM
4185 - Verify GPS active is checked
Instruction
Published
05/18/2022 1:46 PM
4173 - IO PackEye Trimble GPS Active Setting
Remark
Published
05/06/2022 3:50 PM
4212 - 4186 - Tap Save; Remark:4174
Procedure Step
Published
05/10/2022 2:01 PM
4186 - Tap Save
Instruction
Published
05/18/2022 1:46 PM
4174 - IO PackEye Trimble Save Settings Button
Remark
Published
05/06/2022 3:51 PM
3941 - 3891 - Verify Connection; Remark:
Procedure Step
Published
04/06/2022 3:54 PM
3891 - Verify Connection
Instruction
Published
04/04/2022 3:31 PM
4213 - 4187 - Navigate to Rates tab; Remark:4175
Procedure Step
Published
05/10/2022 2:02 PM
4187 - Navigate to Rates tab
Instruction
Published
05/18/2022 1:45 PM
4175 - Use the stylus to press the left arrow, selecting the Rates ...
Remark
Published
05/06/2022 3:53 PM
4214 - 4052 - Tap Start; Remark:4125
Procedure Step
Published
05/10/2022 2:02 PM
4052 - Tap Start
Instruction
Published
05/02/2022 10:26 AM
4125 - IO PackEye Trimble Start Button in App
Remark
Published
11/16/2024 8:56 PM
4215 - 4188 - Verify BT adapter pairing; Remark:4176
Procedure Step
Published
05/10/2022 2:03 PM
4188 - Verify BT adapter pairing
Instruction
Published
05/10/2022 1:35 PM
4176 - There will be solid red and blue lights and a flashing yellow light.
Remark
Published
05/06/2022 3:54 PM
4226 - 4189 - Verify Trimble is retrieving data; Remark:4163
Procedure Step
Published
05/10/2022 2:04 PM
4189 - Verify Trimble is retrieving data
Instruction
Published
05/10/2022 1:36 PM
4163 - Radiation levels will change every second.
Remark
Published
05/06/2022 12:59 PM
253 - 242 - Document and report any unresolved problems; Remark:
Procedure Step
Published
06/22/2021 10:23 AM
242 - Document and report any unresolved problems
Instruction
Published
04/21/2025 11:45 AM
Operator Procedure
Document Type
Published
03/02/2020 3:31 PM
Caution
Annotation Type
Published
03/02/2020 3:24 PM
Note
Annotation Type
Published
03/02/2020 3:25 PM
Trimble Juno
Tools
Published
04/28/2022 12:46 PM
BT adapter
Tools
Published
04/28/2022 12:46 PM
RS232 BT adapter cable
Tools
Published
04/28/2022 12:46 PM
Power off Packeye
Image
Published
02/19/2022 1:48 AM
packeye_di_opentop_redarrow_00758.jpg
Image
Published
10/20/2023 12:55 PM
packeye_di_rs232atfht681_redbox_00759.jpg
Image
Published
10/20/2023 12:56 PM
packeye_di_rs232cable_redoval_00760.jpg
Image
Published
10/20/2023 12:58 PM
packeye_di_rs232btaconnect_redbox_00761.jpg
Image
Published
10/20/2023 12:57 PM
packeye_di_bta_lm048_redbox.jpg
Image
Published
10/20/2023 3:57 PM
packeye_di_dteswitch_lm048_redarrow.jpg
Image
Published
10/20/2023 4:01 PM
packeye_di_bta_serialnumb3_redbox.jpg
Image
Published
10/20/2023 3:58 PM
packeye_ui_power_on_00719
Image
Published
02/07/2022 1:46 AM
packeye_di_bta_lm680_active_redbox_00770.jpg
Image
Published
10/20/2023 10:52 AM
packeye_di_trmb_pwrbutton_redcircle.jpg
Image
Published
10/20/2023 4:38 PM
packeye_ui_trmb_pda681app.jpg
Image
Published
10/23/2023 9:08 AM
packeye_ui_trmb_oktoproceed.jpg
Image
Published
10/20/2023 4:41 PM
packeye_ui_trmb_set_arrows1.jpg
Image
Published
10/20/2023 4:26 PM
packeye_ui_trmb_set_bta_search.jpg
Image
Published
10/20/2023 4:24 PM
packeye_ui_trmb_set_bta_serialnumber.jpg
Image
Published
10/20/2023 4:23 PM
packeye_ui_trmb_set_btablue.jpg
Image
Published
10/20/2023 4:21 PM
packeye_ui_trmb_set_activefht.jpg
Image
Published
10/20/2023 4:20 PM
packeye_ui_trmb_set_activegps.jpg
Image
Published
10/20/2023 4:18 PM
packeye_ui_trmb_set_save.jpg
Image
Published
10/20/2023 4:16 PM
packeye_ui_trmb_ratesbtn__noconnect_full.jpg
Image
Published
10/20/2023 4:13 PM
packeye_ui_trmb_startbtn_full.jpg
Image
Published
10/23/2023 9:06 AM
packeye_di_bta_lm048_active_yellow_redbox.jpg
Image
Published
10/20/2023 3:55 PM
packeye_ui_trmb_rates_G0,074.jpg
Image
Published
10/23/2023 9:04 AM
packeye_ui_trmb_graph_fluc_lrgbox.jpg
Image
Published
10/23/2023 9:03 AM

PackEye Operation

Last Updated: 04/26/2025 1:39 AM

The following table lists all the components that make up the document.

Title Type Status Last Updated
Thermo FHT1377 PackEye
Device
Published
10/28/2024 3:37 PM
3983 - 257 - Prepare instrument; Remark:
Procedure Step
Published
04/14/2022 3:18 PM
3978 - Note : Do not remove components from the backpack. Apply a rain c...
Annotation
Published
04/13/2025 5:36 PM
257 - Prepare instrument
Instruction
Published
04/11/2025 9:07 PM
3984 - 3969 - Disconnect instrument from charger (if needed); Remark:3946
Procedure Step
Published
04/14/2022 3:12 PM
3979 - Note : The battery takes 12 to 18 hours to fully charge. The backup battery and back...
Annotation
Published
04/14/2022 7:54 AM
3969 - Disconnect instrument from charger (if needed)
Instruction
Published
04/14/2022 7:41 AM
3946 - Rotate the collar counterclockwise and pull.
Remark
Published
04/12/2022 1:37 PM
786 - 219 - Verify there are no sources of radiation near instrument; Remark:7
Procedure Step
Published
04/20/2025 6:37 PM
219 - Verify there are no sources of radiation near instrument
Instruction
Published
04/12/2025 4:20 PM
7 - No Radiation symbol
Remark
Published
07/12/2021 1:34 PM
3852 - 220 - Power on instrument; Remark:3836
Procedure Step
Published
03/29/2022 1:59 AM
220 - Power on instrument
Instruction
Published
04/06/2025 7:00 PM
3836 - Press power button on the indicator unit for approximately 1 second.
Remark
Published
03/29/2022 1:05 AM
3853 - 612 - Wait for instrument to complete start-up sequence; Remark:3837
Procedure Step
Published
04/13/2025 6:49 PM
612 - Wait for instrument to complete start-up sequence
Instruction
Published
04/13/2025 6:38 PM
3837 - Initialization and background measurement may take about 20 seconds. During t...
Remark
Published
03/29/2022 1:08 AM
3854 - 3825 - Verify instrument is ready; Remark:3838
Procedure Step
Published
03/29/2022 2:01 AM
3825 - Verify instrument is ready
Instruction
Published
03/28/2022 6:15 PM
3838 - The flashing green nat light indicates PackEye is ready for ...
Remark
Published
03/29/2022 1:10 AM
3990 - 2295 - Verify sufficient battery charge; Remark:3947
Procedure Step
Published
04/15/2022 11:19 AM
2295 - Verify sufficient battery charge
Instruction
Published
04/06/2021 4:43 PM
3947 - Press and hold neutron button. If battery light is solid, there is sufficient...
Remark
Published
04/12/2022 1:40 PM
3991 - 831 - Adjust volume as needed; Remark:3948
Procedure Step
Published
04/15/2022 11:23 AM
831 - Adjust volume as needed
Instruction
Published
10/26/2020 5:33 PM
3948 - To increase volume, hold the power button and press the gamm...
Remark
Published
04/12/2022 1:42 PM
3949 - To decrease volume, hold the power button and press neutron ...
Remark
Published
04/12/2022 1:44 PM
3992 - 3974 - Select mode for operation; Remark:3950
Procedure Step
Published
04/15/2022 11:22 AM
3974 - Select mode for operation
Instruction
Published
04/14/2022 7:44 AM
3950 - Briefly press the power button to switch between Alarm (Search) mode and Chir...
Remark
Published
04/12/2022 1:47 PM
3951 - Alarm (Search) mode: green LED is off.
Remark
Published
04/12/2022 1:48 PM
3952 - Chirper (Finder) mode: green LED is on.
Remark
Published
04/12/2022 1:50 PM
3994 - 319 - Perform operational test; Remark:3964
Procedure Step
Published
04/15/2022 11:28 AM
319 - Perform operational test
Instruction
Published
06/10/2021 8:31 PM
3964 - It is recommended to perform an operational test daily before use. DET-HHD-TH...
Remark
Published
04/12/2022 2:12 PM
410 - 7519 - Locate radioactive material; Remark:
Procedure Step
Published
04/13/2025 6:17 PM
7519 - Locate radioactive material
Instruction
Published
04/13/2025 5:47 PM
3857 - 3827 - Select Alarm mode; Remark:3841
Procedure Step
Published
03/29/2022 2:04 AM
3827 - Select Alarm mode
Instruction
Published
03/28/2022 6:17 PM
3841 - The green LED is off. Briefly press power button to change modes.
Remark
Published
03/29/2022 1:15 AM
3993 - 3977 - Search area; Remark:3953
Procedure Step
Published
04/15/2022 11:25 AM
3977 - Search area
Instruction
Published
04/14/2022 7:47 AM
3953 - Use search techniques appropriate for the situation.
Remark
Published
04/12/2022 1:51 PM
3995 - 367 - Observe instrument response; Remark:3954
Procedure Step
Published
04/15/2022 11:53 AM
3980 - Note : It is normal to observe up to two radiation level lights due to background fl...
Annotation
Published
04/14/2022 7:56 AM
367 - Observe instrument response
Instruction
Published
06/11/2021 9:21 AM
3954 - More than two flashing orange lights indicate the detection of a gamma source...
Remark
Published
04/12/2022 1:53 PM
3955 - More than two flashing blue lights indicate the detection of a neutron source...
Remark
Published
04/12/2022 1:55 PM
3996 - 2357 - Acknowledge alarms; Remark:3956
Procedure Step
Published
04/15/2022 11:55 AM
2357 - Acknowledge alarms
Instruction
Published
07/23/2021 9:29 PM
3956 - Press gamma button to acknowledge (ack) a gamma alarm.
Remark
Published
04/12/2022 1:56 PM
3957 - Press neutron button to acknowledge (ack) a neutron alarm.
Remark
Published
04/12/2022 1:58 PM
3997 - 3831 - Select Chirper mode; Remark:3958
Procedure Step
Published
04/15/2022 11:57 AM
3831 - Select Chirper mode
Instruction
Published
03/28/2022 6:21 PM
3958 - Briefly press the power button. The green LED should be on. In Chirper (Finde...
Remark
Published
04/12/2022 2:00 PM
3998 - 846 - Walk slowly in the area of interest; Remark:3959
Procedure Step
Published
04/15/2022 11:58 AM
846 - Walk slowly in the area of interest
Instruction
Published
07/29/2021 4:15 PM
3959 - IO PackEye Walk Slow Around Car
Remark
Published
04/12/2022 2:02 PM
3999 - 367 - Observe instrument response; Remark:3960
Procedure Step
Published
04/15/2022 11:59 AM
3960 - IO PackEye Gamma Alarm Indicator Red Box
Remark
Published
04/12/2022 2:04 PM
4000 - 853 - Locate area with highest level of radiation; Remark:3961
Procedure Step
Published
04/15/2022 12:01 PM
853 - Locate area with highest level of radiation
Instruction
Published
10/26/2020 6:59 PM
3961 - A gradual 360° turn might be needed to determine the direction of the source...
Remark
Published
04/12/2022 2:06 PM
405 - 368 - Mark point(s) of interest; Remark:4277
Procedure Step
Published
04/20/2025 5:44 PM
368 - Mark point(s) of interest
Instruction
Published
06/11/2021 9:23 AM
4277 - Place a marker (tape, pencil, etc.) on points exhibiting elevated radiation. ...
Remark
Published
04/20/2025 5:37 PM
4002 - 375 - Document results; Remark:3963
Procedure Step
Published
04/15/2022 12:03 PM
375 - Document results
Instruction
Published
06/11/2021 9:37 AM
3963 - Document the distribution of radiation, locations of concentrated radiation l...
Remark
Published
04/12/2022 2:11 PM
3869 - 313 - Power off instrument; Remark:3850
Procedure Step
Published
03/29/2022 2:23 AM
313 - Power off instrument
Instruction
Published
07/23/2021 2:41 PM
3850 - Press and hold the power button for approximately 10 seconds until indicator ...
Remark
Published
03/29/2022 1:38 AM
3985 - 315 - Connect charger; Remark:3965
Procedure Step
Published
04/14/2022 3:13 PM
315 - Connect charger
Instruction
Published
07/20/2021 10:45 AM
3965 - Open the backpack to access the power module. Push the connector and turn the...
Remark
Published
04/12/2022 2:15 PM
Operator Procedure
Document Type
Published
03/02/2020 3:31 PM
Note
Annotation Type
Published
03/02/2020 3:25 PM
Earpiece (optional)
Tools
Published
04/11/2022 1:05 PM
packeye_di_charger_disconnect_redarrow_00782.jpg
Image
Published
10/20/2023 12:54 PM
No Radiation Symbol
Image
Published
08/13/2024 2:56 PM
packeye_ui_power_on_00719
Image
Published
02/07/2022 1:46 AM
PackEye art light highlighted
Image
Published
02/19/2022 1:48 AM
PackEye Nat light flashing
Image
Published
02/19/2022 1:48 AM
Packeye battery charge
Image
Published
02/19/2022 1:48 AM
Packeye adjust gamma volume
Image
Published
04/15/2022 1:06 PM
Neutron_volume.png
Image
Published
02/19/2022 1:48 AM
Power button and nat light
Image
Published
02/19/2022 1:48 AM
Alarm mode
Image
Published
02/19/2022 1:48 AM
Chirper mode
Image
Published
02/19/2022 1:48 AM
Packeye search area
Image
Published
02/19/2022 1:48 AM
Gamma alarm
Image
Published
02/19/2022 1:48 AM
Neutron alarm
Image
Published
02/19/2022 1:48 AM
Packeye acknowledge gamma alarm
Image
Published
02/19/2022 1:48 AM
Packeye walk slowly
Image
Published
02/19/2022 1:48 AM
Packeye 360 degree turn
Image
Published
02/19/2022 1:48 AM
Mark_Source_Location_Trefoil
Image
Published
02/19/2023 10:54 AM
Power off Packeye
Image
Published
02/19/2022 1:48 AM
packeye_di_opentop_redarrow_00758.jpg
Image
Published
10/20/2023 12:55 PM
packeye_di_charger_connect_redarrow_00783.jpg
Image
Published
10/20/2023 12:53 PM

PackEye Operational Test

Last Updated: 04/26/2025 1:39 AM

The following table lists all the components that make up the document.

Title Type Status Last Updated
Thermo FHT1377 PackEye
Device
Published
10/28/2024 3:37 PM
247 - 257 - Prepare instrument; Remark:
Procedure Step
Published
04/11/2025 9:08 PM
257 - Prepare instrument
Instruction
Published
04/11/2025 9:07 PM
786 - 219 - Verify there are no sources of radiation near instrument; Remark:7
Procedure Step
Published
04/20/2025 6:37 PM
219 - Verify there are no sources of radiation near instrument
Instruction
Published
04/12/2025 4:20 PM
7 - No Radiation symbol
Remark
Published
07/12/2021 1:34 PM
3852 - 220 - Power on instrument; Remark:3836
Procedure Step
Published
03/29/2022 1:59 AM
220 - Power on instrument
Instruction
Published
04/06/2025 7:00 PM
3836 - Press power button on the indicator unit for approximately 1 second.
Remark
Published
03/29/2022 1:05 AM
3853 - 612 - Wait for instrument to complete start-up sequence; Remark:3837
Procedure Step
Published
04/13/2025 6:49 PM
612 - Wait for instrument to complete start-up sequence
Instruction
Published
04/13/2025 6:38 PM
3837 - Initialization and background measurement may take about 20 seconds. During t...
Remark
Published
03/29/2022 1:08 AM
3854 - 3825 - Verify instrument is ready; Remark:3838
Procedure Step
Published
03/29/2022 2:01 AM
3825 - Verify instrument is ready
Instruction
Published
03/28/2022 6:15 PM
3838 - The flashing green nat light indicates PackEye is ready for ...
Remark
Published
03/29/2022 1:10 AM
3855 - 3826 - Verify fail light is off; Remark:3839
Procedure Step
Published
03/29/2022 2:02 AM
3826 - Verify fail light is off
Instruction
Published
03/28/2022 6:16 PM
3839 - Solid yellow light: neutron detector or electronic failure.
Remark
Published
03/29/2022 1:12 AM
3840 - Flashing yellow light: high gamma radiation level or gamma detector failure.
Remark
Published
03/29/2022 1:13 AM
3856 - 1437 - Verify Response to Gamma Source; Remark:
Procedure Step
Published
03/29/2022 2:03 AM
1437 - Verify Response to Gamma Source
Instruction
Published
09/01/2020 7:45 PM
3857 - 3827 - Select Alarm mode; Remark:3841
Procedure Step
Published
03/29/2022 2:04 AM
3827 - Select Alarm mode
Instruction
Published
03/28/2022 6:17 PM
3841 - The green LED is off. Briefly press power button to change modes.
Remark
Published
03/29/2022 1:15 AM
3858 - 3828 - Place gamma source on instrument; Remark:3842
Procedure Step
Published
03/29/2022 2:05 AM
3828 - Place gamma source on instrument
Instruction
Published
03/28/2022 6:18 PM
3842 - IO PackEye Gamma Source Placed
Remark
Published
03/29/2022 1:23 AM
3859 - 1439 - Verify instrument responds to radioactive source; Remark:3843
Procedure Step
Published
03/29/2022 2:06 AM
1439 - Verify instrument responds to radioactive source
Instruction
Published
06/29/2022 11:50 PM
3843 - Additional gamma indicator lights will illuminate on indicator unit and an au...
Remark
Published
03/29/2022 1:22 AM
3860 - 3829 - Acknowledge gamma alarm; Remark:3844
Procedure Step
Published
03/29/2022 2:07 AM
3829 - Acknowledge gamma alarm
Instruction
Published
03/28/2022 6:20 PM
3844 - Briefly press gamma button to acknowledge alarm.
Remark
Published
03/29/2022 1:25 AM
3835 - 3830 - Move source away from instrument; Remark:246
Procedure Step
Published
03/28/2022 6:31 PM
3830 - Move source away from instrument
Instruction
Published
03/28/2022 6:20 PM
246 - IO No source trefoil
Remark
Published
10/07/2024 11:39 AM
3861 - 3831 - Select Chirper mode; Remark:3845
Procedure Step
Published
03/29/2022 2:08 AM
3831 - Select Chirper mode
Instruction
Published
03/28/2022 6:21 PM
3845 - The green LED is on. Briefly press power button to change modes.
Remark
Published
03/29/2022 1:26 AM
3871 - 3828 - Place gamma source on instrument; Remark:3842
Procedure Step
Published
04/04/2022 11:00 AM
3862 - 1439 - Verify instrument responds to radioactive source; Remark:3846
Procedure Step
Published
03/29/2022 2:09 AM
3846 - Additional gamma indicator lights will illuminate. Audible chirper pitch will...
Remark
Published
03/29/2022 1:28 AM
3872 - 3830 - Move source away from instrument; Remark:246
Procedure Step
Published
04/04/2022 11:00 AM
3863 - 3832 - Verify Response to Neutron Source; Remark:
Procedure Step
Published
03/29/2022 2:10 AM
3832 - Verify Response to Neutron Source
Instruction
Published
03/29/2022 2:56 AM
3864 - 3827 - Select Alarm mode; Remark:3841
Procedure Step
Published
03/29/2022 2:11 AM
3865 - 3833 - Place neutron source on instrument; Remark:3847
Procedure Step
Published
03/29/2022 2:17 AM
3833 - Place neutron source on instrument
Instruction
Published
03/28/2022 6:24 PM
3847 - IO PackEye Neutron Source Placed
Remark
Published
03/29/2022 1:32 AM
3866 - 1439 - Verify instrument responds to radioactive source; Remark:3848
Procedure Step
Published
03/29/2022 2:19 AM
3848 - Additional neutron indicator lights will illuminate and an alarm will sound. ...
Remark
Published
03/29/2022 1:34 AM
3867 - 3834 - Acknowledge neutron alarm; Remark:3849
Procedure Step
Published
03/29/2022 2:20 AM
3834 - Acknowledge neutron alarm
Instruction
Published
03/28/2022 6:25 PM
3849 - Briefly press neutron button to acknowledge alarm.
Remark
Published
03/29/2022 1:35 AM
3873 - 3833 - Place neutron source on instrument; Remark:3847
Procedure Step
Published
04/04/2022 11:15 AM
3868 - 1439 - Verify instrument responds to radioactive source; Remark:3851
Procedure Step
Published
04/04/2022 11:03 AM
3851 - Additional neutron indicator lights will illuminate and an alarm will sound. ...
Remark
Published
04/01/2022 1:26 PM
3869 - 313 - Power off instrument; Remark:3850
Procedure Step
Published
03/29/2022 2:23 AM
313 - Power off instrument
Instruction
Published
07/23/2021 2:41 PM
3850 - Press and hold the power button for approximately 10 seconds until indicator ...
Remark
Published
03/29/2022 1:38 AM
253 - 242 - Document and report any unresolved problems; Remark:
Procedure Step
Published
06/22/2021 10:23 AM
242 - Document and report any unresolved problems
Instruction
Published
04/21/2025 11:45 AM
Routine Maintenance Procedure
Document Type
Published
03/02/2020 3:31 PM
10 minutes
Duration
Published
04/01/2020 11:35 AM
Annually
Frequency
Published
04/01/2020 11:37 AM
Daily
Frequency
Published
04/01/2020 11:36 AM
Technician 1
Skill Level
Published
05/14/2020 2:56 PM
None
Tools
Published
05/06/2020 9:50 PM
No Radiation Symbol
Image
Published
08/13/2024 2:56 PM
packeye_ui_power_on_00719
Image
Published
02/07/2022 1:46 AM
PackEye art light highlighted
Image
Published
02/19/2022 1:48 AM
PackEye Nat light flashing
Image
Published
02/19/2022 1:48 AM
packeye_fail_solid_yellow.jpg
Image
Published
10/20/2023 10:36 AM
packeye_fail_flashing_yellow.jpg
Image
Published
10/20/2023 10:36 AM
Alarm mode
Image
Published
02/19/2022 1:48 AM
packeye_radsource_placeright.jpg
Image
Published
10/20/2023 10:46 AM
packeye_gamma_radsource_indicator.jpg
Image
Published
10/20/2023 10:39 AM
Packeye acknowledge gamma alarm
Image
Published
02/19/2022 1:48 AM
Chirper mode
Image
Published
02/19/2022 1:48 AM
packeye_gamma_radsource_chirp.jpg
Image
Published
10/20/2023 10:38 AM
packeye_neutronradsource_placeright.jpg
Image
Published
10/20/2023 10:45 AM
packeye_neutron_radsource_indicator.jpg
Image
Published
10/20/2023 10:44 AM
Acknowledge_neutron.png
Image
Published
02/19/2022 1:48 AM
packeye_neutron_radsource_chirp.jpg
Image
Published
10/20/2023 10:43 AM
Power off Packeye
Image
Published
02/19/2022 1:48 AM

PRM-470 CGN Operation

Last Updated: 04/26/2025 1:35 AM

The following table lists all the components that make up the document.

Title Type Status Last Updated
Rapiscan PRM-470 CG
Device
Published
10/28/2024 3:40 PM
Rapiscan PRM-470 CGN
Device
Published
10/28/2024 3:33 PM
247 - 257 - Prepare instrument; Remark:
Procedure Step
Published
04/11/2025 9:08 PM
257 - Prepare instrument
Instruction
Published
04/11/2025 9:07 PM
786 - 219 - Verify there are no sources of radiation near instrument; Remark:7
Procedure Step
Published
04/20/2025 6:37 PM
219 - Verify there are no sources of radiation near instrument
Instruction
Published
04/12/2025 4:20 PM
7 - No Radiation symbol
Remark
Published
07/12/2021 1:34 PM
250 - 220 - Power on instrument; Remark:228
Procedure Step
Published
07/29/2021 11:06 AM
220 - Power on instrument
Instruction
Published
04/06/2025 7:00 PM
228 - Press POWER button until the display turns on.
Remark
Published
06/18/2021 6:29 PM
412 - 2220 - Wait for measurement to complete; Remark:385
Procedure Step
Published
04/20/2025 12:45 PM
2220 - Wait for measurement to complete
Instruction
Published
10/22/2020 11:15 AM
385 - IO Display PRM-470 obtaining background
Remark
Published
11/02/2024 9:41 PM
3067 - 319 - Perform operational test; Remark:3066
Procedure Step
Published
06/10/2021 8:32 PM
319 - Perform operational test
Instruction
Published
06/10/2021 8:31 PM
3066 - It is recommended to perform an operational test daily before use. DET-HHD-RA...
Remark
Published
06/10/2021 8:31 PM
251 - 229 - Press LIGHT button to brighten display (if needed); Remark:231
Procedure Step
Published
06/10/2021 8:33 PM
229 - Press LIGHT button to brighten display (if needed)
Instruction
Published
07/29/2021 11:08 AM
231 - IO PRM-470 Light Button Red Box
Remark
Published
11/04/2024 9:49 PM
411 - 363 - Select mode; Remark:387
Procedure Step
Published
06/10/2021 8:36 PM
379 - Note : It is recommended to start in SEARCH MODE. Once a source of radiation is dete...
Annotation
Published
10/06/2022 12:48 PM
363 - Select mode
Instruction
Published
06/10/2021 8:35 PM
387 - Press the S/F button to change between SEARCH MODE and FIND ...
Remark
Published
06/10/2021 8:34 PM
410 - 7519 - Locate radioactive material; Remark:
Procedure Step
Published
04/13/2025 6:17 PM
7519 - Locate radioactive material
Instruction
Published
04/13/2025 5:47 PM
3410 - 233 - Verify instrument is in SEARCH MODE; Remark:234
Procedure Step
Published
06/08/2021 8:14 PM
233 - Verify instrument is in SEARCH MODE
Instruction
Published
06/10/2021 8:46 PM
234 - Use S/F button to change between SEARCH MODE and FIND MODE.
Remark
Published
07/29/2021 11:11 AM
3409 - PRM-470 CGN Search Mode screen
Remark
Published
09/21/2024 8:50 AM
3108 - S/F mode key red box
Remark
Published
11/02/2024 10:09 PM
409 - 408 - Survey close to surface of item; Remark:388
Procedure Step
Published
06/10/2021 8:50 PM
408 - Survey close to surface of item
Instruction
Published
06/10/2021 8:50 PM
388 - Maintain a distance of approximately 5 to 10 cm from surface of item. Do not ...
Remark
Published
06/10/2021 8:49 PM
407 - 366 - Survey slowly over entire item; Remark:389
Procedure Step
Published
06/11/2021 9:10 AM
366 - Survey slowly over entire item
Instruction
Published
06/11/2021 9:10 AM
389 - Move instrument approximately 20 cm per second. Thoroughly survey all accessi...
Remark
Published
06/11/2021 9:10 AM
3073 - 3071 - Change to FIND MODE when alarm is constant; Remark:3072
Procedure Step
Published
06/11/2021 9:19 AM
3071 - Change to FIND MODE when alarm is constant
Instruction
Published
06/11/2021 9:19 AM
3072 - FIND MODE is recommended for locating a concentrated source.
Remark
Published
06/11/2021 9:17 AM
3412 - 367 - Observe instrument response; Remark:3411
Procedure Step
Published
06/08/2021 8:28 PM
367 - Observe instrument response
Instruction
Published
06/11/2021 9:21 AM
3411 - Use crosshair technique to localize.
Remark
Published
06/23/2021 6:23 PM
405 - 368 - Mark point(s) of interest; Remark:4277
Procedure Step
Published
04/20/2025 5:44 PM
368 - Mark point(s) of interest
Instruction
Published
06/11/2021 9:23 AM
4277 - Place a marker (tape, pencil, etc.) on points exhibiting elevated radiation. ...
Remark
Published
04/20/2025 5:37 PM
384 - 370 - Collect new background measurement (if needed); Remark:
Procedure Step
Published
06/11/2021 9:27 AM
378 - Note : A new background may be needed if: performing a survey in a...
Annotation
Published
06/11/2021 9:26 AM
370 - Collect new background measurement (if needed)
Instruction
Published
06/11/2021 9:26 AM
3070 - 870 - Move to new location; Remark:3069
Procedure Step
Published
06/11/2021 9:29 AM
870 - Move to new location
Instruction
Published
06/11/2021 9:28 AM
3069 - Move instrument to area where new background radiation measurement is needed....
Remark
Published
06/11/2021 9:28 AM
397 - 313 - Power off instrument; Remark:398
Procedure Step
Published
06/11/2021 9:31 AM
313 - Power off instrument
Instruction
Published
07/23/2021 2:41 PM
398 - Press and hold the POWER button until instrument powers off....
Remark
Published
06/18/2021 6:02 PM
399 - 375 - Document results; Remark:394
Procedure Step
Published
06/11/2021 9:46 AM
375 - Document results
Instruction
Published
06/11/2021 9:37 AM
394 - Document results per Standard Operating Procedures.
Remark
Published
06/11/2021 9:36 AM
396 - 376 - Connect charger; Remark:395
Procedure Step
Published
06/11/2021 9:50 AM
377 - Caution : Power off instrument prior to connecting to external power.
Annotation
Published
06/11/2021 9:49 AM
376 - Connect charger
Instruction
Published
06/11/2021 9:49 AM
395 - Charge instrument when not in use.
Remark
Published
06/11/2021 9:48 AM
Operator Procedure
Document Type
Published
03/02/2020 3:31 PM
Note
Annotation Type
Published
03/02/2020 3:25 PM
Caution
Annotation Type
Published
03/02/2020 3:24 PM
No Radiation Symbol
Image
Published
08/13/2024 2:56 PM
PRM-470_Partial_Power_Button_Red_Highlight.png
Image
Published
06/18/2021 6:28 PM
PRM-470 Display Obtaining Background
Image
Published
03/31/2021 9:52 PM
PRM-470_Partial-View_Light-Button_RED-Highlight.png
Image
Published
05/05/2020 9:17 PM
PRM-470_Partial-View_S-F-Button_RED-Highlight.png
Image
Published
04/01/2021 11:22 PM
PRM-470 CGN Search Mode screen
Image
Published
06/09/2021 2:41 AM
prm-470_Raster_Survey_000047.png
Image
Published
04/02/2021 1:44 AM
PRM470_Find_Mode_Gamma.png
Image
Published
03/15/2021 3:35 PM
PRM-470 Survey Search Crosshair Four Yellow Arrows
Image
Published
05/09/2020 5:06 PM
Mark_Source_Location_Trefoil
Image
Published
02/19/2023 10:54 AM

PRM-470 CG Operation

Last Updated: 04/26/2025 1:35 AM

The following table lists all the components that make up the document.

Title Type Status Last Updated
Rapiscan PRM-470 CG
Device
Published
10/28/2024 3:40 PM
247 - 257 - Prepare instrument; Remark:
Procedure Step
Published
04/11/2025 9:08 PM
257 - Prepare instrument
Instruction
Published
04/11/2025 9:07 PM
786 - 219 - Verify there are no sources of radiation near instrument; Remark:7
Procedure Step
Published
04/20/2025 6:37 PM
219 - Verify there are no sources of radiation near instrument
Instruction
Published
04/12/2025 4:20 PM
7 - No Radiation symbol
Remark
Published
07/12/2021 1:34 PM
250 - 220 - Power on instrument; Remark:228
Procedure Step
Published
07/29/2021 11:06 AM
220 - Power on instrument
Instruction
Published
04/06/2025 7:00 PM
228 - Press POWER button until the display turns on.
Remark
Published
06/18/2021 6:29 PM
412 - 2220 - Wait for measurement to complete; Remark:385
Procedure Step
Published
04/20/2025 12:45 PM
2220 - Wait for measurement to complete
Instruction
Published
10/22/2020 11:15 AM
385 - IO Display PRM-470 obtaining background
Remark
Published
11/02/2024 9:41 PM
3067 - 319 - Perform operational test; Remark:3066
Procedure Step
Published
06/10/2021 8:32 PM
319 - Perform operational test
Instruction
Published
06/10/2021 8:31 PM
3066 - It is recommended to perform an operational test daily before use. DET-HHD-RA...
Remark
Published
06/10/2021 8:31 PM
251 - 229 - Press LIGHT button to brighten display (if needed); Remark:231
Procedure Step
Published
06/10/2021 8:33 PM
229 - Press LIGHT button to brighten display (if needed)
Instruction
Published
07/29/2021 11:08 AM
231 - IO PRM-470 Light Button Red Box
Remark
Published
11/04/2024 9:49 PM
411 - 363 - Select mode; Remark:387
Procedure Step
Published
06/10/2021 8:36 PM
379 - Note : It is recommended to start in SEARCH MODE. Once a source of radiation is dete...
Annotation
Published
10/06/2022 12:48 PM
363 - Select mode
Instruction
Published
06/10/2021 8:35 PM
387 - Press the S/F button to change between SEARCH MODE and FIND ...
Remark
Published
06/10/2021 8:34 PM
410 - 7519 - Locate radioactive material; Remark:
Procedure Step
Published
04/13/2025 6:17 PM
7519 - Locate radioactive material
Instruction
Published
04/13/2025 5:47 PM
333 - 233 - Verify instrument is in SEARCH MODE; Remark:234
Procedure Step
Published
06/25/2021 12:41 PM
233 - Verify instrument is in SEARCH MODE
Instruction
Published
06/10/2021 8:46 PM
234 - Use S/F button to change between SEARCH MODE and FIND MODE.
Remark
Published
07/29/2021 11:11 AM
751 - IO PRM-470 Search Mode 65 CPS Gamma
Remark
Published
10/29/2024 9:31 PM
3108 - S/F mode key red box
Remark
Published
11/02/2024 10:09 PM
409 - 408 - Survey close to surface of item; Remark:388
Procedure Step
Published
06/10/2021 8:50 PM
408 - Survey close to surface of item
Instruction
Published
06/10/2021 8:50 PM
388 - Maintain a distance of approximately 5 to 10 cm from surface of item. Do not ...
Remark
Published
06/10/2021 8:49 PM
407 - 366 - Survey slowly over entire item; Remark:389
Procedure Step
Published
06/11/2021 9:10 AM
366 - Survey slowly over entire item
Instruction
Published
06/11/2021 9:10 AM
389 - Move instrument approximately 20 cm per second. Thoroughly survey all accessi...
Remark
Published
06/11/2021 9:10 AM
3073 - 3071 - Change to FIND MODE when alarm is constant; Remark:3072
Procedure Step
Published
06/11/2021 9:19 AM
3071 - Change to FIND MODE when alarm is constant
Instruction
Published
06/11/2021 9:19 AM
3072 - FIND MODE is recommended for locating a concentrated source.
Remark
Published
06/11/2021 9:17 AM
406 - 367 - Observe instrument response; Remark:386
Procedure Step
Published
06/11/2021 9:22 AM
367 - Observe instrument response
Instruction
Published
06/11/2021 9:21 AM
386 - Use crosshair technique to localize.
Remark
Published
06/11/2021 9:20 AM
405 - 368 - Mark point(s) of interest; Remark:4277
Procedure Step
Published
04/20/2025 5:44 PM
368 - Mark point(s) of interest
Instruction
Published
06/11/2021 9:23 AM
4277 - Place a marker (tape, pencil, etc.) on points exhibiting elevated radiation. ...
Remark
Published
04/20/2025 5:37 PM
384 - 370 - Collect new background measurement (if needed); Remark:
Procedure Step
Published
06/11/2021 9:27 AM
378 - Note : A new background may be needed if: performing a survey in a...
Annotation
Published
06/11/2021 9:26 AM
370 - Collect new background measurement (if needed)
Instruction
Published
06/11/2021 9:26 AM
3070 - 870 - Move to new location; Remark:3069
Procedure Step
Published
06/11/2021 9:29 AM
870 - Move to new location
Instruction
Published
06/11/2021 9:28 AM
3069 - Move instrument to area where new background radiation measurement is needed....
Remark
Published
06/11/2021 9:28 AM
397 - 313 - Power off instrument; Remark:398
Procedure Step
Published
06/11/2021 9:31 AM
313 - Power off instrument
Instruction
Published
07/23/2021 2:41 PM
398 - Press and hold the POWER button until instrument powers off....
Remark
Published
06/18/2021 6:02 PM
2701 - 220 - Power on instrument; Remark:3068
Procedure Step
Published
06/11/2021 9:34 AM
3068 - Press POWER button until display turns on.
Remark
Published
06/11/2021 9:33 AM
399 - 375 - Document results; Remark:394
Procedure Step
Published
06/11/2021 9:46 AM
375 - Document results
Instruction
Published
06/11/2021 9:37 AM
394 - Document results per Standard Operating Procedures.
Remark
Published
06/11/2021 9:36 AM
396 - 376 - Connect charger; Remark:395
Procedure Step
Published
06/11/2021 9:50 AM
377 - Caution : Power off instrument prior to connecting to external power.
Annotation
Published
06/11/2021 9:49 AM
376 - Connect charger
Instruction
Published
06/11/2021 9:49 AM
395 - Charge instrument when not in use.
Remark
Published
06/11/2021 9:48 AM
Operator Procedure
Document Type
Published
03/02/2020 3:31 PM
Note
Annotation Type
Published
03/02/2020 3:25 PM
Caution
Annotation Type
Published
03/02/2020 3:24 PM
None
Tools
Published
05/06/2020 9:50 PM
No Radiation Symbol
Image
Published
08/13/2024 2:56 PM
PRM-470_Partial_Power_Button_Red_Highlight.png
Image
Published
06/18/2021 6:28 PM
PRM-470 Display Obtaining Background
Image
Published
03/31/2021 9:52 PM
PRM-470_Partial-View_Light-Button_RED-Highlight.png
Image
Published
05/05/2020 9:17 PM
PRM-470_Partial-View_S-F-Button_RED-Highlight.png
Image
Published
04/01/2021 11:22 PM
PRM-470 Display SEARCH
Image
Published
04/01/2021 11:22 PM
prm-470_Raster_Survey_000047.png
Image
Published
04/02/2021 1:44 AM
Mark_Source_Location_Trefoil
Image
Published
02/19/2023 10:54 AM