RPM SC-770 Rabbit Board Firmware Update

Last Updated: 04/24/2025 1:45 AM

The following table lists all the components that make up the document.

Title Type Status Last Updated
Rapiscan CM-267 Conveyor Monitor
Device
Published
06/27/2024 1:02 PM
Rapiscan PM-700 Pedestrian Monitor
Device
Published
06/20/2024 11:38 AM
Rapiscan TM-850 Rail Monitor
Device
Published
09/18/2024 10:28 AM
Rapiscan VM-250 Vehicle Monitor
Device
Published
10/14/2024 9:50 AM
9517 - 9230 - Prepare Laptop and Software; Remark:
Procedure Step
Published
10/03/2023 3:54 PM
9230 - Prepare Laptop and Software
Instruction
Published
10/02/2023 9:10 AM
9509 - 9420 - Verify appropriate USB‑to-serial drivers are installed for adapter; Remark:9458
Procedure Step
Published
10/03/2023 3:55 PM
9420 - Verify appropriate USB‑to-serial drivers are installed for adapter
Instruction
Published
10/03/2023 1:55 PM
9458 - Incorrect drivers will result in communication issues and failure to communic...
Remark
Published
10/03/2023 3:24 PM
9784 - IO Serial Connector
Remark
Published
04/20/2025 11:02 AM
9510 - 9421 - Verify RFU software is installed; Remark:9459
Procedure Step
Published
10/03/2023 3:55 PM
9421 - Verify RFU software is installed
Instruction
Published
10/03/2023 1:55 PM
9459 - RFU needs to contain: Coldload.bin Flash.ini
Remark
Published
04/13/2025 6:08 PM
9511 - 9422 - Start RFU software; Remark:9460
Procedure Step
Published
10/03/2023 3:55 PM
9422 - Start RFU software
Instruction
Published
10/03/2023 1:55 PM
9460 - The file may have “application” as the type.
Remark
Published
10/03/2023 3:27 PM
9512 - 9423 - Select “Communications” from Setup File Menu; Remark:9542
Procedure Step
Published
10/03/2023 3:56 PM
9423 - Select “Communications” from Setup File Menu
Instruction
Published
10/03/2023 1:56 PM
9542 - IO RFU Rabbit Programming Select Communication from Setup File Menu
Remark
Published
04/20/2025 11:03 AM
9513 - 9424 - Verify Comm Port is same on USB-to-serial driver and RFU software; Remark:9461
Procedure Step
Published
10/03/2023 3:56 PM
9424 - Verify Comm Port is same on USB-to-serial driver and RFU software
Instruction
Published
10/03/2023 1:56 PM
9461 - COM Port information is found in the computer’s Device Manager. The RFU sof...
Remark
Published
10/03/2023 3:27 PM
9514 - 9425 - Verify Baud Rate is same on USB-to-serial driver and RFU software; Remark:9462
Procedure Step
Published
10/03/2023 3:57 PM
9454 - Note : The USB Serial Port will list bits per second and the communication options will...
Annotation
Published
10/03/2023 2:42 PM
9425 - Verify Baud Rate is same on USB-to-serial driver and RFU software
Instruction
Published
10/03/2023 1:57 PM
9462 - The USB Serial Port Properties may be accessed by Right-Clicking on USB Seria...
Remark
Published
10/03/2023 3:28 PM
9515 - 9426 - Verify remaining RFU software parameters; Remark:9463
Procedure Step
Published
10/03/2023 3:57 PM
9426 - Verify remaining RFU software parameters
Instruction
Published
10/03/2023 1:57 PM
9463 - Deselect “Enabled Processor Detection” and select “Use USB to Serial Co...
Remark
Published
10/03/2023 3:28 PM
9516 - 9427 - Click “OK” to close Communications Options; Remark:
Procedure Step
Published
10/03/2023 3:57 PM
9427 - Click “OK” to close Communications Options
Instruction
Published
10/03/2023 1:57 PM
7264 - 1401 - Establish Initial Conditions; Remark:
Procedure Step
Published
04/27/2023 7:00 PM
1401 - Establish Initial Conditions
Instruction
Published
09/30/2022 3:14 PM
7622 - 7592 - Inform system operators; Remark:11335
Procedure Step
Published
04/20/2025 10:15 AM
7592 - Inform system operators
Instruction
Published
06/29/2023 3:20 PM
11335 - Upon arrival, brief system operators on expected work, duration, anticipated ...
Remark
Published
04/20/2025 10:14 AM
7268 - 7231 - Close lane; Remark:7233
Procedure Step
Published
04/27/2023 7:01 PM
9053 - Warning : Traffic should temporarily be rerouted or halted during conduction of this pr...
Annotation
Published
09/27/2023 9:09 AM
7231 - Close lane
Instruction
Published
04/18/2023 1:00 PM
7233 - Use orange safety (traffic control) cones to setup barriers. Practice establi...
Remark
Published
04/24/2023 12:18 PM
7269 - 7232 - Open RPM door; Remark:7234
Procedure Step
Published
04/27/2023 7:02 PM
7232 - Open RPM door
Instruction
Published
04/18/2023 1:02 PM
7234 - Open all doors needed to access components.
Remark
Published
04/19/2025 7:48 PM
7280 - 7250 - Power on RPM; Remark:7251
Procedure Step
Published
04/27/2023 4:14 PM
7250 - Power on RPM
Instruction
Published
05/01/2023 8:31 AM
7251 - Move LD-260 switch to ON position. The LED PWR ON
Remark
Published
05/10/2023 3:14 PM
7281 - 7252 - Verify RPM start-up; Remark:7253
Procedure Step
Published
04/20/2025 3:26 PM
7252 - Verify RPM start-up
Instruction
Published
04/27/2023 2:23 PM
7253 - RPM will perform a power on self-test (POST) and collect a background radiati...
Remark
Published
05/10/2023 3:14 PM
9504 - 9430 - Verify existing firmware is not current; Remark:9464
Procedure Step
Published
10/03/2023 4:01 PM
9430 - Verify existing firmware is not current
Instruction
Published
10/03/2023 1:59 PM
9464 - Enter Program Mode by pressing “0.” Enter the password ...
Remark
Published
10/16/2023 11:18 AM
9465 - The displayed version number indicates the firmware version installed on the ...
Remark
Published
10/03/2023 3:31 PM
9505 - 9431 - Record parameter settings; Remark:9466
Procedure Step
Published
10/03/2023 4:01 PM
9431 - Record parameter settings
Instruction
Published
10/03/2023 1:59 PM
9466 - Reference Vehicle and Pedestrian Monitor VM-250AGN/PM-700AGN Operations &...
Remark
Published
10/03/2023 3:32 PM
7755 - 7679 - Disconnect Ethernet; Remark:11336
Procedure Step
Published
04/20/2025 11:18 AM
7680 - Caution : Make sure to press release button on back of Ethernet cable before removing.
Annotation
Published
07/01/2023 11:54 PM
7679 - Disconnect Ethernet
Instruction
Published
07/01/2023 11:52 PM
11336 - Locate Ethernet connector on top of SC-770 controller. Press release button o...
Remark
Published
04/20/2025 11:21 AM
7270 - 7235 - Power off RPM; Remark:7236
Procedure Step
Published
09/01/2023 7:57 PM
7235 - Power off RPM
Instruction
Published
04/24/2023 12:30 PM
7236 - Move LD-260 switch to OFF position. The PWR ON
Remark
Published
04/27/2023 4:25 PM
9498 - 9434 - Connect Computer to Rabbit Board; Remark:
Procedure Step
Published
10/03/2023 4:02 PM
9434 - Connect Computer to Rabbit Board
Instruction
Published
10/03/2023 2:00 PM
9494 - 9435 - Loosen screws in each corner (4) using a medium Philips screwdriver and open ...; Remark:7797
Procedure Step
Published
10/03/2023 4:03 PM
9455 - Caution : If you rotate the cover of the SC-770 down without first pulling out from the...
Annotation
Published
10/03/2023 2:43 PM
9435 - Loosen screws in each corner (4) using a medium Philips screwdriver and open ...
Instruction
Published
10/03/2023 2:00 PM
7797 - Normally the cover screws are captured and should not come out of cover. ...
Remark
Published
07/07/2023 2:34 PM
9467 - To prevent breaking the hinge on the module / door, once the retainer screws ...
Remark
Published
10/03/2023 3:32 PM
9495 - 9436 - Connect Rabbit programming cable to USB-to-serial on laptop; Remark:
Procedure Step
Published
10/03/2023 4:03 PM
9436 - Connect Rabbit programming cable to USB-to-serial on laptop
Instruction
Published
10/03/2023 2:01 PM
9496 - 9437 - Connect Rabbit programming cable to 10-pin head connector on Rabbit board...; Remark:9468
Procedure Step
Published
10/03/2023 4:04 PM
9437 - Connect Rabbit programming cable to 10-pin head connector on Rabbit board...
Instruction
Published
10/03/2023 2:01 PM
9468 - The connector on the end of the cable will not work for programming. Use the ...
Remark
Published
10/03/2023 3:33 PM
9493 - 9438 - Update Firmware; Remark:
Procedure Step
Published
10/03/2023 4:05 PM
9456 - Note : SC-770 should display “V2.6” or similar number depending on the current f...
Annotation
Published
10/03/2023 2:45 PM
9438 - Update Firmware
Instruction
Published
10/03/2023 2:01 PM
9487 - 9439 - Select “Load Flash Image” from File drop-down menu; Remark:9540
Procedure Step
Published
10/03/2023 4:05 PM
9439 - Select “Load Flash Image” from File drop-down menu
Instruction
Published
10/03/2023 2:02 PM
9540 -
Remark
Published
10/04/2023 3:22 PM
9488 - 9440 - Click on small dotted box; Remark:9539
Procedure Step
Published
10/03/2023 4:05 PM
9440 - Click on small dotted box
Instruction
Published
10/03/2023 2:02 PM
9539 -
Remark
Published
10/04/2023 3:22 PM
9489 - 9441 - Select .bin file and click “Open”; Remark:9538
Procedure Step
Published
10/03/2023 4:06 PM
9457 - Caution : Verify correct firmware file (.bin) is loaded.
Annotation
Published
10/03/2023 2:46 PM
9441 - Select .bin file and click “Open”
Instruction
Published
10/03/2023 2:03 PM
9538 -
Remark
Published
10/04/2023 3:23 PM
9490 - 9442 - Select “OK”; Remark:9537
Procedure Step
Published
10/03/2023 4:06 PM
9442 - Select “OK”
Instruction
Published
10/03/2023 2:03 PM
9537 -
Remark
Published
10/04/2023 3:23 PM
9491 - 9443 - Wait for firmware installation to complete; Remark:9469
Procedure Step
Published
10/03/2023 4:07 PM
9443 - Wait for firmware installation to complete
Instruction
Published
10/03/2023 2:03 PM
9469 - Ensure the program loads by verifying that the completion bar increases from ...
Remark
Published
10/03/2023 3:33 PM
9470 - If the firmware upload is unsuccessful, reboot the computer, power cycle the ...
Remark
Published
10/03/2023 3:33 PM
7279 - 7249 - Return equipment to normal operating condition; Remark:
Procedure Step
Published
04/27/2023 4:13 PM
7249 - Return equipment to normal operating condition
Instruction
Published
04/08/2025 3:22 PM
9478 - 9446 - Disconnect Rabbit programming cable from 10-pin connector on Rabbit board...; Remark:
Procedure Step
Published
10/03/2023 4:09 PM
9446 - Disconnect Rabbit programming cable from 10-pin connector on Rabbit board...
Instruction
Published
10/03/2023 2:04 PM
9479 - 9447 - Close controller but do not secure; Remark:
Procedure Step
Published
10/03/2023 4:09 PM
9447 - Close controller but do not secure
Instruction
Published
10/03/2023 2:38 PM
9482 - 9450 - Verify firmware was successfully updated; Remark:9464
Procedure Step
Published
10/03/2023 4:10 PM
9450 - Verify firmware was successfully updated
Instruction
Published
10/03/2023 2:39 PM
9471 - The displayed version number indicates the firmware version installed on the ...
Remark
Published
10/03/2023 3:37 PM
9483 - 9451 - Verify SC-770 parameter setting are correct; Remark:8196
Procedure Step
Published
10/03/2023 4:10 PM
9451 - Verify SC-770 parameter setting are correct
Instruction
Published
10/03/2023 2:39 PM
8196 - Every RPM has unique parameter settings. The currently approved parameter set...
Remark
Published
09/01/2023 7:30 PM
8584 - 8458 - Exit programming mode; Remark:8554
Procedure Step
Published
09/17/2023 11:00 PM
8458 - Exit programming mode
Instruction
Published
09/15/2023 4:21 PM
8554 - On SC-770, press # button until main controller screen is di...
Remark
Published
09/17/2023 9:40 PM
7781 - 7730 - Reconnect Ethernet; Remark:7731
Procedure Step
Published
04/20/2025 11:00 AM
7730 - Reconnect Ethernet
Instruction
Published
07/02/2023 2:34 AM
7731 - Insert Ethernet connector at top of SC-770 module. Connector will audibly "cl...
Remark
Published
07/02/2023 2:36 AM
7842 - 7820 - Inform system operators upon completion of maintenance action; Remark:
Procedure Step
Published
07/07/2023 11:15 PM
7820 - Inform system operators upon completion of maintenance action
Instruction
Published
07/07/2023 10:02 PM
322 - 321 - Document maintenance actions; Remark:
Procedure Step
Published
06/17/2021 9:49 AM
321 - Document maintenance actions
Instruction
Published
04/21/2025 11:19 AM
2869 - 2585 - Document maintenance performed; Remark:2866
Procedure Step
Published
06/18/2021 5:58 PM
2585 - Document maintenance performed
Instruction
Published
07/09/2021 12:15 PM
2866 - Record observations, times, and results for the maintenance report.
Remark
Published
04/21/2025 11:39 AM
4706 - 4705 - Submit report; Remark:4864
Procedure Step
Published
06/29/2022 9:50 AM
4705 - Submit report
Instruction
Published
06/29/2022 9:50 AM
4864 - As specified by management or contractual obligations.
Remark
Published
07/28/2022 1:36 PM
Corrective Maintenance Procedure
Document Type
Published
03/02/2020 3:32 PM
minutes
Duration
Published
05/26/2022 11:41 AM
Installation of new Rabbit board that needs firmware update
Frequency
Published
10/04/2023 9:06 AM
Update firmware version
Frequency
Published
10/04/2023 9:06 AM
Note
Annotation Type
Published
03/02/2020 3:25 PM
Warning
Annotation Type
Published
03/02/2020 3:25 PM
Caution
Annotation Type
Published
03/02/2020 3:24 PM
Technician 2
Skill Level
Published
04/09/2020 1:17 AM
Keys to access RPM
Replacement Parts
Published
04/27/2023 6:56 PM
Reflective safety vest if required
Replacement Parts
Published
06/20/2023 4:47 PM
Ladder; 2 meters, 6 feet tall; non-conducting if required
Replacement Parts
Published
07/02/2023 4:48 PM
Traffic control cones or equivalent if required
Replacement Parts
Published
06/20/2023 4:47 PM
Special Rabbit board programming cable
Tools
Published
10/04/2023 9:07 AM
Laptop: Rabbit Field Utility (RFU) software, Applicable USB (universal serial bus)-to-serial drivers
Tools
Published
10/04/2023 9:08 AM
USB/Serial adapter
Tools
Published
05/09/2020 4:02 PM
Medium Phillips (PH2) screwdriver
Tools
Published
04/24/2020 4:40 PM
Current firmware update file (e.g., 1.10.1H.bin)
Tools
Published
10/04/2023 9:09 AM
Serial Connector
Image
Published
10/16/2023 10:39 AM
USB to serial adapter
Image
Published
10/16/2023 11:13 AM
Start RFU software
Image
Published
10/04/2023 2:53 PM
Select “Communications” from Setup File Menu
Image
Published
10/04/2023 2:54 PM
Computer Device Manager
Image
Published
10/04/2023 2:56 PM
USB Serial Port selection in Device Manager
Image
Published
10/04/2023 2:56 PM
Verify Baud Rate
Image
Published
10/04/2023 2:57 PM
Verify Baud Rate pt2
Image
Published
10/04/2023 2:58 PM
Verify remaining RFU software parameters
Image
Published
10/04/2023 2:58 PM
LD-260 Disconnect Switch Power On
Image
Published
05/04/2023 3:37 PM
Disconnect Ethernet cable on top of SC-770 box
Image
Published
10/04/2023 2:59 PM
LD-260 Disconnect Switch Power Off
Image
Published
04/24/2023 12:49 PM
Remove Six (6) Cover Screws
Image
Published
07/07/2023 2:27 PM
Cover screws are captured
Image
Published
10/04/2023 3:01 PM
To prevent breaking the hinge
Image
Published
10/04/2023 3:02 PM
Connect rabbit programming cable to 10-pin head connector on Rabbit board
Image
Published
10/04/2023 3:03 PM
Connect rabbit programming cable to 10-pin head connector on Rabbit board pt2
Image
Published
10/04/2023 3:03 PM
Select “Load Flash Image” from File drop-down menu
Image
Published
10/04/2023 3:04 PM
Click on small dotted box
Image
Published
10/04/2023 3:05 PM
Select .bin file and click “Open”
Image
Published
10/04/2023 3:05 PM
Select “OK”
Image
Published
10/04/2023 3:06 PM
Wait for firmware installation to complete
Image
Published
10/04/2023 3:07 PM