RPM HHV-448/458 High Voltage Board Replacement

Last Updated: 04/23/2025 1:42 AM

The following table lists all the components that make up the document.

Title Type Status Last Updated
Rapiscan VM-250 Vehicle Monitor
Device
Published
10/14/2024 9:50 AM
Rapiscan PM-700 Pedestrian Monitor
Device
Published
06/20/2024 11:38 AM
Rapiscan TM-850 Rail Monitor
Device
Published
09/18/2024 10:28 AM
Rapiscan CM-267 Conveyor Monitor
Device
Published
06/27/2024 1:02 PM
9508 - 1401 - Establish Initial Conditions; Remark:
Procedure Step
Published
10/03/2023 3:58 PM
1401 - Establish Initial Conditions
Instruction
Published
09/30/2022 3:14 PM
8490 - 7592 - Inform system operators; Remark:
Procedure Step
Published
09/16/2023 8:49 PM
7592 - Inform system operators
Instruction
Published
06/29/2023 3:20 PM
8221 - 7676 - Brief system operators on expected work, duration, anticipated alarms, and fa...; Remark:
Procedure Step
Published
09/01/2023 9:26 PM
7676 - Brief system operators on expected work, duration, anticipated alarms, and fa...
Instruction
Published
07/01/2023 11:39 PM
10312 - 7967 - Close lane and set up barriers or establish a safety watch; Remark:7595
Procedure Step
Published
11/17/2023 8:47 AM
7967 - Close lane and set up barriers or establish a safety watch
Instruction
Published
07/12/2023 12:41 AM
7595 - Use orange safety (traffic control) cones or equivalent per site-specific saf...
Remark
Published
06/29/2023 3:33 PM
7270 - 7235 - Power off RPM; Remark:7236
Procedure Step
Published
09/01/2023 7:57 PM
7235 - Power off RPM
Instruction
Published
04/24/2023 12:30 PM
7236 - Move LD-260 switch to OFF position. The PWR ON
Remark
Published
04/27/2023 4:25 PM
9646 - 9645 - Prepare for Faulty High Voltage Board Removal; Remark:
Procedure Step
Published
04/13/2025 6:15 PM
9645 - Prepare for Faulty High Voltage Board Removal
Instruction
Published
04/13/2025 6:02 PM
7852 - 7849 - Disconnect two cables on bottom of SCA-775 module; Remark:7851
Procedure Step
Published
07/08/2023 11:51 PM
7849 - Disconnect two cables on bottom of SCA-775 module
Instruction
Published
07/08/2023 11:46 PM
7851 - Connectors are disconnected by turning lock ring multiple times and then pull...
Remark
Published
07/08/2023 11:50 PM
7855 - 7853 - Disconnect all BNC and miniature high voltage (MHV) cables on top of SCA-775 ...; Remark:7854
Procedure Step
Published
07/08/2023 11:59 PM
7792 - Note : It is good engineering practice to ensure all cables and connectors are label...
Annotation
Published
07/07/2023 2:17 PM
7853 - Disconnect all BNC and miniature high voltage (MHV) cables on top of SCA-775 ...
Instruction
Published
07/08/2023 11:56 PM
7854 - BNC Connectors
Remark
Published
07/08/2023 11:58 PM
9709 - 9435 - Loosen screws in each corner (4) using a medium Philips screwdriver and open ...; Remark:9708
Procedure Step
Published
10/11/2023 10:48 PM
9435 - Loosen screws in each corner (4) using a medium Philips screwdriver and open ...
Instruction
Published
10/03/2023 2:00 PM
9708 - Normally the cover screws are “captured” and should not come out of the c...
Remark
Published
10/11/2023 10:47 PM
7861 - 7859 - Remove 4 mounting screws; Remark:7860
Procedure Step
Published
07/09/2023 12:12 AM
7858 - Note : Most replaceable bit type screwdrivers will be too large in diameter to fit i...
Annotation
Published
07/09/2023 12:06 AM
7859 - Remove 4 mounting screws
Instruction
Published
07/09/2023 12:07 AM
7860 - The screws to be removed are located in the bottom of the irregularly shaped ...
Remark
Published
07/09/2023 12:11 AM
7863 - 7862 - Remove SCA-775 module from back plate; Remark:
Procedure Step
Published
07/09/2023 12:15 AM
7862 - Remove SCA-775 module from back plate
Instruction
Published
07/09/2023 12:14 AM
7830 - 7799 - Disconnect 4 wiring harness assembly/connectors (J6, J8, J10, J11) from SCA-7...; Remark:7800
Procedure Step
Published
07/07/2023 11:04 PM
7798 - Caution : Never remove connectors by pulling on wires.
Annotation
Published
07/07/2023 5:41 PM
7799 - Disconnect 4 wiring harness assembly/connectors (J6, J8, J10, J11) from SCA-7...
Instruction
Published
07/07/2023 5:44 PM
7800 - J8 and J11 should be labeled; write J6 and J10 on the appropriate connector i...
Remark
Published
07/07/2023 9:27 PM
9658 - 9647 - Remove SCA-774 board from SCA-775 module; Remark:9648
Procedure Step
Published
10/11/2023 8:15 PM
9647 - Remove SCA-774 board from SCA-775 module
Instruction
Published
10/11/2023 7:55 PM
9648 - BNC connectors are attached to the SCA-774 board and easily slide down then o...
Remark
Published
10/11/2023 7:58 PM
9657 - 9650 - Uninstall Faulty High Voltage Board; Remark:
Procedure Step
Published
10/11/2023 8:14 PM
9649 - Note : If spare SCA-775 boxes or mounting plates are available it is advisable to re...
Annotation
Published
10/11/2023 8:00 PM
9650 - Uninstall Faulty High Voltage Board
Instruction
Published
10/11/2023 8:01 PM
9653 - 9651 - Remove four corners screws from high voltage plate to remove from box; Remark:9652
Procedure Step
Published
10/11/2023 8:07 PM
9651 - Remove four corners screws from high voltage plate to remove from box
Instruction
Published
10/11/2023 8:05 PM
9652 - High voltage plate
Remark
Published
10/11/2023 8:06 PM
9656 - 9654 - Disconnect wiring harness from faulty board(s); Remark:9655
Procedure Step
Published
10/11/2023 8:13 PM
9654 - Disconnect wiring harness from faulty board(s)
Instruction
Published
10/11/2023 8:09 PM
9655 - Faulty High Voltage Board
Remark
Published
10/11/2023 8:11 PM
9661 - 9659 - Remove faulty board; Remark:9660
Procedure Step
Published
10/11/2023 8:19 PM
9659 - Remove faulty board
Instruction
Published
10/11/2023 8:15 PM
9660 - Using a small Phillips screwdriver, remove screws at four corners.
Remark
Published
04/13/2025 6:02 PM
9707 - 9705 - Cut ground wire (black) and high-voltage wires (orange) as close to bad board...; Remark:9706
Procedure Step
Published
10/11/2023 10:39 PM
9705 - Cut ground wire (black) and high-voltage wires (orange) as close to bad board...
Instruction
Published
10/11/2023 10:37 PM
9706 -
Remark
Published
10/11/2023 10:38 PM
3397 - 3395 - Label faulty component; Remark:3396
Procedure Step
Published
07/21/2024 6:59 AM
3395 - Label faulty component
Instruction
Published
08/07/2021 11:07 AM
3396 - Use tag or tape. Include date of removal, description of failure symptoms, co...
Remark
Published
08/09/2021 11:35 AM
9696 - 9690 - Install New High Voltage Board (HHV-448 or HHV-458); Remark:
Procedure Step
Published
10/11/2023 9:31 PM
9690 - Install New High Voltage Board (HHV-448 or HHV-458)
Instruction
Published
10/11/2023 9:20 PM
9697 - 9691 - Strip approximately 3/8” of insulation off ground and high voltage wire fro...; Remark:
Procedure Step
Published
10/11/2023 9:32 PM
9691 - Strip approximately 3/8” of insulation off ground and high voltage wire fro...
Instruction
Published
10/11/2023 9:21 PM
9698 - 9692 - Cut “tinned” ends off of new high voltage board wires and strip approxima...; Remark:9693
Procedure Step
Published
10/11/2023 9:32 PM
9692 - Cut “tinned” ends off of new high voltage board wires and strip approxima...
Instruction
Published
10/11/2023 9:22 PM
9693 - Do not twist wires by hand
Remark
Published
10/11/2023 9:25 PM
9699 - 9694 - Slip sealed solder butt splice connector over one wire; Remark:9695
Procedure Step
Published
10/11/2023 9:33 PM
9694 - Slip sealed solder butt splice connector over one wire
Instruction
Published
10/11/2023 9:29 PM
9695 - Match wires and splice (intermingle) wire strands to form butt joint.
Remark
Published
10/11/2023 9:30 PM
9700 - 9689 - Place splice connector so solder ferrule is in center of splice; Remark:9688
Procedure Step
Published
10/11/2023 9:34 PM
9689 - Place splice connector so solder ferrule is in center of splice
Instruction
Published
10/11/2023 9:19 PM
9688 - Splice Connection
Remark
Published
10/11/2023 9:18 PM
9701 - 9686 - Heat with heat gun; Remark:9685
Procedure Step
Published
10/11/2023 9:35 PM
9687 - Caution : Do not overheat the wire and/or circuit boards when using heat gun. Do not po...
Annotation
Published
10/11/2023 9:16 PM
9686 - Heat with heat gun
Instruction
Published
10/11/2023 9:15 PM
9685 - Starting at center, gently distribute heat to ends until the inner tube is fu...
Remark
Published
10/11/2023 9:14 PM
9702 - 9683 - Wait for wires to cool; Remark:9684
Procedure Step
Published
10/11/2023 9:36 PM
9683 - Wait for wires to cool
Instruction
Published
10/11/2023 9:10 PM
9684 - Pull on wires to verify good connection.
Remark
Published
10/11/2023 9:11 PM
9703 - 9682 - Repeat steps 4-2 through 4-5 for each connection; Remark:
Procedure Step
Published
10/11/2023 9:36 PM
9682 - Repeat steps 4-2 through 4-5 for each connection
Instruction
Published
10/11/2023 9:10 PM
7279 - 7249 - Return equipment to normal operating condition; Remark:
Procedure Step
Published
04/27/2023 4:13 PM
7249 - Return equipment to normal operating condition
Instruction
Published
04/08/2025 3:22 PM
9681 - 9675 - Reinstall 4 screws to mount board back to 4 posts; Remark:9676
Procedure Step
Published
10/11/2023 9:07 PM
9675 - Reinstall 4 screws to mount board back to 4 posts
Instruction
Published
10/11/2023 9:01 PM
9676 - Mounting High Voltage Board
Remark
Published
10/11/2023 9:02 PM
9680 - 9673 - Reattach wiring harness; Remark:9674
Procedure Step
Published
10/11/2023 9:06 PM
7808 - Caution : Proper connection of wiring harnesses is critical.
Annotation
Published
07/07/2023 9:39 PM
9673 - Reattach wiring harness
Instruction
Published
10/11/2023 8:59 PM
9674 - Reattach wiring harness
Remark
Published
10/11/2023 9:00 PM
9679 - 9671 - Reinstall plate on SCA-775 module; Remark:9672
Procedure Step
Published
10/11/2023 9:05 PM
9671 - Reinstall plate on SCA-775 module
Instruction
Published
10/11/2023 8:56 PM
9672 - SCA-775 Plate
Remark
Published
10/11/2023 8:57 PM
9678 - 9670 - Ensure all connectors are securely mated to board; Remark:
Procedure Step
Published
10/11/2023 9:04 PM
9670 - Ensure all connectors are securely mated to board
Instruction
Published
10/11/2023 8:48 PM
9677 - 9668 - Secure SCA-774 board; Remark:9669
Procedure Step
Published
10/11/2023 9:03 PM
9668 - Secure SCA-774 board
Instruction
Published
10/11/2023 8:47 PM
9669 - Use screws previously removed.
Remark
Published
10/11/2023 8:48 PM
7835 - 7809 - Reconnect 4 wiring harness assembly/connectors (J6, J8, J10, J11) from SCA-77...; Remark:7810
Procedure Step
Published
10/11/2023 7:37 PM
7809 - Reconnect 4 wiring harness assembly/connectors (J6, J8, J10, J11) from SCA-77...
Instruction
Published
07/07/2023 9:42 PM
7810 - Ensure all pins are engaged. It is easy to install the connectors one pin off...
Remark
Published
07/07/2023 9:44 PM
9667 - 9665 - Reinstall 4 corner screws to mount SCA-775 module; Remark:9666
Procedure Step
Published
10/11/2023 8:30 PM
9665 - Reinstall 4 corner screws to mount SCA-775 module
Instruction
Published
10/11/2023 8:28 PM
9666 - Install all screws loosely at first to facilitate easy mounting, then careful...
Remark
Published
10/11/2023 8:30 PM
7836 - 7813 - Reconnect BNC connectors on top of SCA-775 module; Remark:
Procedure Step
Published
07/07/2023 11:42 PM
7811 - Caution : Proper connection of cables is critical.
Annotation
Published
07/07/2023 9:48 PM
7813 - Reconnect BNC connectors on top of SCA-775 module
Instruction
Published
07/07/2023 9:49 PM
7879 - 7878 - Reattach two connectors on bottom of SCA-775 module; Remark:7870
Procedure Step
Published
07/09/2023 1:16 AM
7878 - Reattach two connectors on bottom of SCA-775 module
Instruction
Published
07/09/2023 1:15 AM
7870 - The cable connectors are different sizes and keyed so they cannot be reinstal...
Remark
Published
07/09/2023 12:26 AM
8874 - 7250 - Power on RPM; Remark:7251
Procedure Step
Published
09/25/2023 2:12 PM
7250 - Power on RPM
Instruction
Published
05/01/2023 8:31 AM
7251 - Move LD-260 switch to ON position. The LED PWR ON
Remark
Published
05/10/2023 3:14 PM
7281 - 7252 - Verify RPM start-up; Remark:7253
Procedure Step
Published
04/20/2025 3:26 PM
7252 - Verify RPM start-up
Instruction
Published
04/27/2023 2:23 PM
7253 - RPM will perform a power on self-test (POST) and collect a background radiati...
Remark
Published
05/10/2023 3:14 PM
8506 - 7254 - Confirm network connection; Remark:7255
Procedure Step
Published
09/24/2023 3:34 PM
7254 - Confirm network connection
Instruction
Published
04/27/2023 2:22 PM
7255 - Contact operators to confirm communications have been reestablished between RPM ...
Remark
Published
05/10/2023 3:15 PM
9664 - 9662 - Navigate to SHOW COUNTS on SC-770 to verify gamma counts are...; Remark:9663
Procedure Step
Published
10/11/2023 8:27 PM
9662 - Navigate to SHOW COUNTS on SC-770 to verify gamma counts are...
Instruction
Published
10/11/2023 8:23 PM
9663 - Enter Program Mode by pressing "0" Press 01234#
Remark
Published
04/13/2025 6:01 PM
8580 - 8548 - Navigate to SHOW COUNTS for neutron channels; Remark:8549
Procedure Step
Published
09/17/2023 10:57 PM
8548 - Navigate to SHOW COUNTS for neutron channels
Instruction
Published
09/17/2023 9:22 PM
8549 - On SC-770, press 01234# Then, press 2:
Remark
Published
09/17/2023 9:26 PM
7840 - 7816 - Perform electronic alignment; Remark:7817
Procedure Step
Published
07/07/2023 11:12 PM
7816 - Perform electronic alignment
Instruction
Published
07/07/2023 9:55 PM
7817 - DET-RPM-RAP-CM01, RPM Electronic Alignment Procedure.
Remark
Published
04/13/2025 5:55 PM
8507 - 7256 - Close and lock all RPM doors; Remark:
Procedure Step
Published
09/24/2023 3:35 PM
7256 - Close and lock all RPM doors
Instruction
Published
04/27/2023 2:21 PM
7842 - 7820 - Inform system operators upon completion of maintenance action; Remark:
Procedure Step
Published
07/07/2023 11:15 PM
7820 - Inform system operators upon completion of maintenance action
Instruction
Published
07/07/2023 10:02 PM
322 - 321 - Document maintenance actions; Remark:
Procedure Step
Published
06/17/2021 9:49 AM
321 - Document maintenance actions
Instruction
Published
04/21/2025 11:19 AM
2869 - 2585 - Document maintenance performed; Remark:2866
Procedure Step
Published
06/18/2021 5:58 PM
2585 - Document maintenance performed
Instruction
Published
07/09/2021 12:15 PM
2866 - Record observations, times, and results for the maintenance report.
Remark
Published
04/21/2025 11:39 AM
4706 - 4705 - Submit report; Remark:4864
Procedure Step
Published
06/29/2022 9:50 AM
4705 - Submit report
Instruction
Published
06/29/2022 9:50 AM
4864 - As specified by management or contractual obligations.
Remark
Published
07/28/2022 1:36 PM
Corrective Maintenance Procedure
Document Type
Published
03/02/2020 3:32 PM
Upon failure of HHV-448 and/or HHV-458
Frequency
Published
10/11/2023 9:59 PM
Note
Annotation Type
Published
03/02/2020 3:25 PM
Caution
Annotation Type
Published
03/02/2020 3:24 PM
Technician 2
Skill Level
Published
04/09/2020 1:17 AM
Keys to access RPM
Replacement Parts
Published
04/27/2023 6:56 PM
Reflective safety vest if required
Replacement Parts
Published
06/20/2023 4:47 PM
Ladder; 2 meters, 6 feet tall; non-conducting if required
Replacement Parts
Published
07/02/2023 4:48 PM
Traffic control cones or equivalent if required
Replacement Parts
Published
06/20/2023 4:47 PM
safety glasses
Replacement Parts
Published
07/02/2023 4:48 PM
Medium Phillips (PH2) screwdriver
Tools
Published
04/24/2020 4:40 PM
Phillips screwdriver, small with 80 to 100 mm long shaft
Replacement Parts
Published
07/09/2023 1:06 AM
Small needle nose pliers
Tools
Published
11/21/2022 9:06 AM
Wire Crimpers
Tools
Published
11/03/2022 4:56 PM
Wire stripper
Tools
Published
09/25/2023 4:20 PM
Heat gun
Replacement Parts
Published
10/11/2023 10:10 PM
4 ELA5-16 sealed solder butt splices
Tools
Published
11/17/2023 8:38 AM
LD-260 Disconnect Switch Power Off
Image
Published
04/24/2023 12:49 PM
SCA-775 Two Connectors
Image
Published
07/08/2023 11:48 PM
SCA-775 BNC Connectors
Image
Published
07/08/2023 11:57 PM
SCA-775 Screw Sockets
Image
Published
07/09/2023 12:09 AM
High Voltage Plate on SCA-775 Box
Image
Published
10/11/2023 8:04 PM
Faulty High Voltage Board
Image
Published
10/11/2023 8:11 PM
Remove Faulty High Voltage Board
Image
Published
10/11/2023 8:17 PM
Incorrect Way of Splicing Wires
Image
Published
10/11/2023 9:24 PM
Match Wires When Soldering
Image
Published
10/11/2023 9:28 PM
Slip Solder Connector
Image
Published
10/11/2023 9:28 PM
Splice Connection
Image
Published
10/11/2023 9:18 PM
Heat Solder Connection with Heat Gun
Image
Published
10/11/2023 9:12 PM
Reinstall Wiring Harness for HVB
Image
Published
10/11/2023 8:52 PM
Reinstall SCA-775 Plate
Image
Published
10/11/2023 8:51 PM
LD-260 Disconnect Switch Power On
Image
Published
05/04/2023 3:37 PM

RPM Neutron Signal Pick-Off Box (PMFX) Replacement

Last Updated: 04/23/2025 1:42 AM

The following table lists all the components that make up the document.

Title Type Status Last Updated
Rapiscan CM-267 Conveyor Monitor
Device
Published
06/27/2024 1:02 PM
Rapiscan PM-700 Pedestrian Monitor
Device
Published
06/20/2024 11:38 AM
Rapiscan TM-850 Rail Monitor
Device
Published
09/18/2024 10:28 AM
Rapiscan VM-250 Vehicle Monitor
Device
Published
10/14/2024 9:50 AM
7264 - 1401 - Establish Initial Conditions; Remark:
Procedure Step
Published
04/27/2023 7:00 PM
1401 - Establish Initial Conditions
Instruction
Published
09/30/2022 3:14 PM
7622 - 7592 - Inform system operators; Remark:11335
Procedure Step
Published
04/20/2025 10:15 AM
7592 - Inform system operators
Instruction
Published
06/29/2023 3:20 PM
11335 - Upon arrival, brief system operators on expected work, duration, anticipated ...
Remark
Published
04/20/2025 10:14 AM
7268 - 7231 - Close lane; Remark:7233
Procedure Step
Published
04/27/2023 7:01 PM
9053 - Warning : Traffic should temporarily be rerouted or halted during conduction of this pr...
Annotation
Published
09/27/2023 9:09 AM
7231 - Close lane
Instruction
Published
04/18/2023 1:00 PM
7233 - Use orange safety (traffic control) cones to setup barriers. Practice establi...
Remark
Published
04/24/2023 12:18 PM
7269 - 7232 - Open RPM door; Remark:7234
Procedure Step
Published
04/27/2023 7:02 PM
7232 - Open RPM door
Instruction
Published
04/18/2023 1:02 PM
7234 - Open all doors needed to access components.
Remark
Published
04/19/2025 7:48 PM
7755 - 7679 - Disconnect Ethernet; Remark:11336
Procedure Step
Published
04/20/2025 11:18 AM
7680 - Caution : Make sure to press release button on back of Ethernet cable before removing.
Annotation
Published
07/01/2023 11:54 PM
7679 - Disconnect Ethernet
Instruction
Published
07/01/2023 11:52 PM
11336 - Locate Ethernet connector on top of SC-770 controller. Press release button o...
Remark
Published
04/20/2025 11:21 AM
7270 - 7235 - Power off RPM; Remark:7236
Procedure Step
Published
09/01/2023 7:57 PM
7235 - Power off RPM
Instruction
Published
04/24/2023 12:30 PM
7236 - Move LD-260 switch to OFF position. The PWR ON
Remark
Published
04/27/2023 4:25 PM
9265 - 9223 - Remove PMFX Box; Remark:
Procedure Step
Published
10/02/2023 1:04 PM
9223 - Remove PMFX Box
Instruction
Published
10/03/2023 12:03 PM
9262 - 9224 - Disconnect all signal (BNC) and miniature high voltage (MHV) cables from PMFX...; Remark:
Procedure Step
Published
10/02/2023 1:04 PM
7792 - Note : It is good engineering practice to ensure all cables and connectors are label...
Annotation
Published
07/07/2023 2:17 PM
9224 - Disconnect all signal (BNC) and miniature high voltage (MHV) cables from PMFX...
Instruction
Published
10/02/2023 9:05 AM
9263 - 572 - Remove four (4) cover screws; Remark:9520
Procedure Step
Published
10/02/2023 1:05 PM
572 - Remove four (4) cover screws
Instruction
Published
08/09/2021 1:57 PM
9520 -
Remark
Published
10/04/2023 10:56 AM
9264 - 445 - Remove four (4) mounting screws; Remark:9232
Procedure Step
Published
10/02/2023 1:05 PM
445 - Remove four (4) mounting screws
Instruction
Published
07/22/2021 12:41 PM
9232 - Non-potted version
Remark
Published
10/03/2023 1:07 PM
9233 - Potted version
Remark
Published
10/03/2023 1:07 PM
9234 - Access holes for retaining screws.
Remark
Published
10/03/2023 1:06 PM
3397 - 3395 - Label faulty component; Remark:3396
Procedure Step
Published
07/21/2024 6:59 AM
3395 - Label faulty component
Instruction
Published
08/07/2021 11:07 AM
3396 - Use tag or tape. Include date of removal, description of failure symptoms, co...
Remark
Published
08/09/2021 11:35 AM
9261 - 9225 - Install New PMFX Box; Remark:
Procedure Step
Published
10/02/2023 1:06 PM
9225 - Install New PMFX Box
Instruction
Published
10/03/2023 12:05 PM
9257 - 9226 - Mount PMFX with four screws; Remark:7807
Procedure Step
Published
10/02/2023 1:06 PM
9226 - Mount PMFX with four screws
Instruction
Published
10/03/2023 12:04 PM
7807 - Use screws previously removed.
Remark
Published
07/07/2023 9:38 PM
9258 - 9227 - Reinstall four (4) cover screws; Remark:7807
Procedure Step
Published
10/02/2023 1:07 PM
9227 - Reinstall four (4) cover screws
Instruction
Published
10/02/2023 9:06 AM
9259 - 9228 - Reconnect BNC and MHV connectors to PMFX box; Remark:
Procedure Step
Published
10/02/2023 1:07 PM
9228 - Reconnect BNC and MHV connectors to PMFX box
Instruction
Published
10/02/2023 9:07 AM
7279 - 7249 - Return equipment to normal operating condition; Remark:
Procedure Step
Published
04/27/2023 4:13 PM
7249 - Return equipment to normal operating condition
Instruction
Published
04/08/2025 3:22 PM
7280 - 7250 - Power on RPM; Remark:7251
Procedure Step
Published
04/27/2023 4:14 PM
7250 - Power on RPM
Instruction
Published
05/01/2023 8:31 AM
7251 - Move LD-260 switch to ON position. The LED PWR ON
Remark
Published
05/10/2023 3:14 PM
9254 - 9229 - Verify neutron counts; Remark:9231
Procedure Step
Published
10/02/2023 1:09 PM
9229 - Verify neutron counts
Instruction
Published
10/02/2023 9:07 AM
9231 - Neutron counts can be verified by placing Cf-252 source near front of neutron...
Remark
Published
10/03/2023 1:13 PM
7781 - 7730 - Reconnect Ethernet; Remark:7731
Procedure Step
Published
04/20/2025 11:00 AM
7730 - Reconnect Ethernet
Instruction
Published
07/02/2023 2:34 AM
7731 - Insert Ethernet connector at top of SC-770 module. Connector will audibly "cl...
Remark
Published
07/02/2023 2:36 AM
7283 - 7256 - Close and lock all RPM doors; Remark:
Procedure Step
Published
09/01/2023 11:45 PM
7256 - Close and lock all RPM doors
Instruction
Published
04/27/2023 2:21 PM
9255 - 8250 - Reopen Lane; Remark:
Procedure Step
Published
10/02/2023 1:09 PM
8250 - Reopen Lane
Instruction
Published
09/07/2023 3:09 PM
7842 - 7820 - Inform system operators upon completion of maintenance action; Remark:
Procedure Step
Published
07/07/2023 11:15 PM
7820 - Inform system operators upon completion of maintenance action
Instruction
Published
07/07/2023 10:02 PM
322 - 321 - Document maintenance actions; Remark:
Procedure Step
Published
06/17/2021 9:49 AM
321 - Document maintenance actions
Instruction
Published
04/21/2025 11:19 AM
2869 - 2585 - Document maintenance performed; Remark:2866
Procedure Step
Published
06/18/2021 5:58 PM
2585 - Document maintenance performed
Instruction
Published
07/09/2021 12:15 PM
2866 - Record observations, times, and results for the maintenance report.
Remark
Published
04/21/2025 11:39 AM
4706 - 4705 - Submit report; Remark:4864
Procedure Step
Published
06/29/2022 9:50 AM
4705 - Submit report
Instruction
Published
06/29/2022 9:50 AM
4864 - As specified by management or contractual obligations.
Remark
Published
07/28/2022 1:36 PM
Corrective Maintenance Procedure
Document Type
Published
03/02/2020 3:32 PM
15 minutes
Duration
Published
04/01/2020 11:35 AM
Change from non-potted to potted parts once
Frequency
Published
10/02/2023 1:52 PM
Upon PMFX box failure
Frequency
Published
10/02/2023 1:51 PM
Warning
Annotation Type
Published
03/02/2020 3:25 PM
Caution
Annotation Type
Published
03/02/2020 3:24 PM
Note
Annotation Type
Published
03/02/2020 3:25 PM
Technician 1
Skill Level
Published
05/14/2020 2:56 PM
Medium Phillips (PH2) screwdriver bit
Tools
Published
07/01/2022 11:18 AM
Phillips screwdriver, small with 80 to 100 mm long shaft
Replacement Parts
Published
07/09/2023 1:06 AM
Disconnect Ethernet cable on top of SC-770 box
Image
Published
10/04/2023 2:59 PM
LD-260 Disconnect Switch Power Off
Image
Published
04/24/2023 12:49 PM
Remove four (4) cover Screws
Image
Published
10/02/2023 3:09 PM
non-potted version
Image
Published
10/02/2023 3:10 PM
potted version. Access holes for retaining screws.
Image
Published
10/02/2023 3:12 PM
LD-260 Disconnect Switch Power On
Image
Published
05/04/2023 3:37 PM

RPM SC-770 Controller Module Replacement

Last Updated: 04/23/2025 1:41 AM

The following table lists all the components that make up the document.

Title Type Status Last Updated
Rapiscan CM-267 Conveyor Monitor
Device
Published
06/27/2024 1:02 PM
Rapiscan VM-250 Vehicle Monitor
Device
Published
10/14/2024 9:50 AM
Rapiscan TM-850 Rail Monitor
Device
Published
09/18/2024 10:28 AM
Rapiscan PM-700 Pedestrian Monitor
Device
Published
06/20/2024 11:38 AM
1402 - 7927 - Establish Initial Conditions; Remark:
Procedure Step
Published
09/30/2022 1:47 PM
7927 - Establish Initial Conditions
Instruction
Published
07/12/2023 12:23 AM
7268 - 7231 - Close lane; Remark:7233
Procedure Step
Published
04/27/2023 7:01 PM
9053 - Warning : Traffic should temporarily be rerouted or halted during conduction of this pr...
Annotation
Published
09/27/2023 9:09 AM
7231 - Close lane
Instruction
Published
04/18/2023 1:00 PM
7233 - Use orange safety (traffic control) cones to setup barriers. Practice establi...
Remark
Published
04/24/2023 12:18 PM
7269 - 7232 - Open RPM door; Remark:7234
Procedure Step
Published
04/27/2023 7:02 PM
7232 - Open RPM door
Instruction
Published
04/18/2023 1:02 PM
7234 - Open all doors needed to access components.
Remark
Published
04/19/2025 7:48 PM
8450 - 8449 - Collect and record parameters in SC-770 controller before removing if possibl...; Remark:
Procedure Step
Published
09/15/2023 3:34 PM
8449 - Collect and record parameters in SC-770 controller before removing if possibl...
Instruction
Published
09/15/2023 3:34 PM
7270 - 7235 - Power off RPM; Remark:7236
Procedure Step
Published
09/01/2023 7:57 PM
7235 - Power off RPM
Instruction
Published
04/24/2023 12:30 PM
7236 - Move LD-260 switch to OFF position. The PWR ON
Remark
Published
04/27/2023 4:25 PM
8448 - 8447 - Uninstall Faulty SC-770 Controller Module; Remark:
Procedure Step
Published
09/15/2023 3:37 PM
8447 - Uninstall Faulty SC-770 Controller Module
Instruction
Published
09/15/2023 3:37 PM
8445 - 8444 - Disconnect Ethernet and AMPHENOL cables on SC-770; Remark:8662
Procedure Step
Published
09/15/2023 3:45 PM
7792 - Note : It is good engineering practice to ensure all cables and connectors are label...
Annotation
Published
07/07/2023 2:17 PM
8444 - Disconnect Ethernet and AMPHENOL cables on SC-770
Instruction
Published
09/15/2023 3:41 PM
8662 - Top Cables
Remark
Published
09/20/2023 10:49 AM
8663 - Bottom Cables
Remark
Published
09/20/2023 10:57 AM
8239 - 8238 - Loosen SC-770 cover screws; Remark:8237
Procedure Step
Published
09/06/2023 4:14 PM
8238 - Loosen SC-770 cover screws
Instruction
Published
09/06/2023 4:03 PM
8237 - Use the medium Phillips screwdriver to loosen screws. The screws should be ca...
Remark
Published
09/06/2023 4:14 PM
9716 -
Remark
Published
10/13/2023 2:38 PM
8240 - 8235 - Pull cover straight out and away from SC-770 body before rotating lid down; Remark:9715
Procedure Step
Published
09/06/2023 4:18 PM
8236 - Caution : Do not rotate the lid down before pulling it straight away from the SC-770 bo...
Annotation
Published
09/06/2023 4:18 PM
8235 - Pull cover straight out and away from SC-770 body before rotating lid down
Instruction
Published
09/06/2023 4:17 PM
9715 -
Remark
Published
10/13/2023 2:36 PM
8246 -
Remark
Published
09/06/2023 4:32 PM
8667 - 8666 - Remove four (4) mounting screws; Remark:8665
Procedure Step
Published
09/20/2023 1:44 PM
8666 - Remove four (4) mounting screws
Instruction
Published
09/20/2023 1:41 PM
8665 - The mounting screws are located in a deep pocket in each corner of the ...
Remark
Published
09/20/2023 1:44 PM
8446 - 8443 - Remove SC-770; Remark:8668
Procedure Step
Published
09/15/2023 3:48 PM
8443 - Remove SC-770
Instruction
Published
09/15/2023 3:48 PM
8668 -
Remark
Published
09/20/2023 3:41 PM
3397 - 3395 - Label faulty component; Remark:3396
Procedure Step
Published
07/21/2024 6:59 AM
3395 - Label faulty component
Instruction
Published
08/07/2021 11:07 AM
3396 - Use tag or tape. Include date of removal, description of failure symptoms, co...
Remark
Published
08/09/2021 11:35 AM
8457 - 8456 - Install New SC-770 Controller Module; Remark:
Procedure Step
Published
09/15/2023 3:54 PM
8456 - Install New SC-770 Controller Module
Instruction
Published
09/15/2023 3:54 PM
8099 - 8093 - Install four screws; Remark:
Procedure Step
Published
07/31/2023 7:57 PM
8093 - Install four screws
Instruction
Published
07/31/2023 7:57 PM
8268 - 8261 - Close SC-770 module cover and tighten all screws; Remark:
Procedure Step
Published
09/07/2023 2:50 PM
8261 - Close SC-770 module cover and tighten all screws
Instruction
Published
09/07/2023 2:50 PM
8454 - 8453 - Reconnect Ethernet and AMPHENOL cables; Remark:8452
Procedure Step
Published
09/15/2023 4:02 PM
7811 - Caution : Proper connection of cables is critical.
Annotation
Published
07/07/2023 9:48 PM
8453 - Reconnect Ethernet and AMPHENOL cables
Instruction
Published
09/15/2023 3:59 PM
8452 - Connect Ethernet and AMPHENOL cables on top of SC-770, and AMPHENOL cab...
Remark
Published
09/15/2023 4:02 PM
7279 - 7249 - Return equipment to normal operating condition; Remark:
Procedure Step
Published
04/27/2023 4:13 PM
7249 - Return equipment to normal operating condition
Instruction
Published
04/08/2025 3:22 PM
7280 - 7250 - Power on RPM; Remark:7251
Procedure Step
Published
04/27/2023 4:14 PM
7250 - Power on RPM
Instruction
Published
05/01/2023 8:31 AM
7251 - Move LD-260 switch to ON position. The LED PWR ON
Remark
Published
05/10/2023 3:14 PM
8462 - 8451 - Verify SC-770 firmware version; Remark:8461
Procedure Step
Published
09/15/2023 4:19 PM
8254 - Note : If firmware version is not correct, perform procedure DET-RPM-RAP-CM02 to upd...
Annotation
Published
09/07/2023 2:56 PM
8255 - Caution : The firmware version must be correct to operate the system
Annotation
Published
09/07/2023 2:57 PM
8451 - Verify SC-770 firmware version
Instruction
Published
09/15/2023 4:04 PM
8461 - Enter “Program Mode” by pressing “0.” Enter the password 1234 ...
Remark
Published
09/15/2023 4:19 PM
8463 - 8460 - Program parameters into new SC-770; Remark:8459
Procedure Step
Published
09/15/2023 4:20 PM
8253 - Caution : To ensure proper RPM operation, careful attention must be paid when entering ...
Annotation
Published
09/07/2023 3:00 PM
8460 - Program parameters into new SC-770
Instruction
Published
09/15/2023 4:20 PM
8459 - Use parameters previously recorded in Step 1-3. If those were not recorded, t...
Remark
Published
09/15/2023 4:20 PM
8584 - 8458 - Exit programming mode; Remark:8554
Procedure Step
Published
09/17/2023 11:00 PM
8458 - Exit programming mode
Instruction
Published
09/15/2023 4:21 PM
8554 - On SC-770, press # button until main controller screen is di...
Remark
Published
09/17/2023 9:40 PM
7282 - 7254 - Confirm network connection; Remark:7255
Procedure Step
Published
04/27/2023 4:15 PM
7254 - Confirm network connection
Instruction
Published
04/27/2023 2:22 PM
7255 - Contact operators to confirm communications have been reestablished between RPM ...
Remark
Published
05/10/2023 3:15 PM
8670 - 319 - Perform operational test; Remark:8669
Procedure Step
Published
04/08/2025 2:20 PM
319 - Perform operational test
Instruction
Published
06/10/2021 8:31 PM
8669 - DET-RPM-RAP-RM03, RPM Operational Testing
Remark
Published
09/20/2023 4:18 PM
7842 - 7820 - Inform system operators upon completion of maintenance action; Remark:
Procedure Step
Published
07/07/2023 11:15 PM
7820 - Inform system operators upon completion of maintenance action
Instruction
Published
07/07/2023 10:02 PM
322 - 321 - Document maintenance actions; Remark:
Procedure Step
Published
06/17/2021 9:49 AM
321 - Document maintenance actions
Instruction
Published
04/21/2025 11:19 AM
2869 - 2585 - Document maintenance performed; Remark:2866
Procedure Step
Published
06/18/2021 5:58 PM
2585 - Document maintenance performed
Instruction
Published
07/09/2021 12:15 PM
2866 - Record observations, times, and results for the maintenance report.
Remark
Published
04/21/2025 11:39 AM
4706 - 4705 - Submit report; Remark:4864
Procedure Step
Published
06/29/2022 9:50 AM
4705 - Submit report
Instruction
Published
06/29/2022 9:50 AM
4864 - As specified by management or contractual obligations.
Remark
Published
07/28/2022 1:36 PM
Corrective Maintenance Procedure
Document Type
Published
03/02/2020 3:32 PM
30 minutes
Duration
Published
04/01/2020 11:35 AM
Upon failure of SC-770 Controller Module
Frequency
Published
09/15/2023 10:15 AM
Warning
Annotation Type
Published
03/02/2020 3:25 PM
Note
Annotation Type
Published
03/02/2020 3:25 PM
Caution
Annotation Type
Published
03/02/2020 3:24 PM
Technician 2
Skill Level
Published
04/09/2020 1:17 AM
Keys to access RPM
Replacement Parts
Published
04/27/2023 6:56 PM
Reflective safety vest if required
Replacement Parts
Published
06/20/2023 4:47 PM
Ladder; 2 meters, 6 feet tall; non-conducting if required
Replacement Parts
Published
07/02/2023 4:48 PM
Phillips screwdriver, small with 80 to 100 mm long shaft
Replacement Parts
Published
07/09/2023 1:06 AM
Phillips screwdriver, medium
Replacement Parts
Published
07/07/2023 11:39 PM
LD-260 Disconnect Switch Power Off
Image
Published
04/24/2023 12:49 PM
SC-770 top ethernet and AMPHENOL cables
Image
Published
09/20/2023 10:44 AM
SC-770 bottom ethernet and AMPHENOL cables
Image
Published
09/20/2023 10:47 AM
SC-770 Controller Screws
Image
Published
09/01/2023 5:56 PM
Loosen SC-770 cover screws
Image
Published
09/20/2023 1:14 PM
Loosen SC-770 cover screws zoom in
Image
Published
10/13/2023 2:17 PM
SC-770 lid cover removal instruction
Image
Published
10/13/2023 2:22 PM
SC-770 lid cover removal
Image
Published
09/06/2023 4:31 PM
Remove four mounting screws_0.png
Image
Published
09/20/2023 1:39 PM
Remove SC-770
Image
Published
09/20/2023 3:40 PM
LD-260 Disconnect Switch Power On
Image
Published
05/04/2023 3:37 PM

RPM SCA-775 Module Replacement

Last Updated: 04/23/2025 1:41 AM

The following table lists all the components that make up the document.

Title Type Status Last Updated
Rapiscan VM-250 Vehicle Monitor
Device
Published
10/14/2024 9:50 AM
Rapiscan PM-700 Pedestrian Monitor
Device
Published
06/20/2024 11:38 AM
Rapiscan TM-850 Rail Monitor
Device
Published
09/18/2024 10:28 AM
Rapiscan CM-267 Conveyor Monitor
Device
Published
06/27/2024 1:02 PM
7264 - 1401 - Establish Initial Conditions; Remark:
Procedure Step
Published
04/27/2023 7:00 PM
1401 - Establish Initial Conditions
Instruction
Published
09/30/2022 3:14 PM
7823 - 7592 - Inform system operators; Remark:
Procedure Step
Published
07/07/2023 10:54 PM
7592 - Inform system operators
Instruction
Published
06/29/2023 3:20 PM
7824 - 7676 - Brief system operators on expected work, duration, anticipated alarms, and fa...; Remark:7677
Procedure Step
Published
07/07/2023 10:55 PM
7676 - Brief system operators on expected work, duration, anticipated alarms, and fa...
Instruction
Published
07/01/2023 11:39 PM
7677 - Operators should expect numerous fault indications and alarms during procedur...
Remark
Published
07/02/2023 3:05 AM
7847 - 7594 - Close lane and set up barriers to establish a safety watch; Remark:7846
Procedure Step
Published
07/08/2023 11:41 PM
7678 - Warning : Traffic should temporarily be rerouted or halted during conduction of this pr...
Annotation
Published
07/03/2023 10:23 AM
7594 - Close lane and set up barriers to establish a safety watch
Instruction
Published
06/29/2023 3:28 PM
7846 - Orange safety cones (traffic control) or equivalent per site-specific safety ...
Remark
Published
07/08/2023 11:40 PM
7270 - 7235 - Power off RPM; Remark:7236
Procedure Step
Published
09/01/2023 7:57 PM
7235 - Power off RPM
Instruction
Published
04/24/2023 12:30 PM
7236 - Move LD-260 switch to OFF position. The PWR ON
Remark
Published
04/27/2023 4:25 PM
7850 - 7848 - Removal of SCA-775 Module; Remark:
Procedure Step
Published
07/08/2023 11:48 PM
7848 - Removal of SCA-775 Module
Instruction
Published
07/08/2023 11:45 PM
7852 - 7849 - Disconnect two cables on bottom of SCA-775 module; Remark:7851
Procedure Step
Published
07/08/2023 11:51 PM
7849 - Disconnect two cables on bottom of SCA-775 module
Instruction
Published
07/08/2023 11:46 PM
7851 - Connectors are disconnected by turning lock ring multiple times and then pull...
Remark
Published
07/08/2023 11:50 PM
7855 - 7853 - Disconnect all BNC and miniature high voltage (MHV) cables on top of SCA-775 ...; Remark:7854
Procedure Step
Published
07/08/2023 11:59 PM
7792 - Note : It is good engineering practice to ensure all cables and connectors are label...
Annotation
Published
07/07/2023 2:17 PM
7853 - Disconnect all BNC and miniature high voltage (MHV) cables on top of SCA-775 ...
Instruction
Published
07/08/2023 11:56 PM
7854 - BNC Connectors
Remark
Published
07/08/2023 11:58 PM
7857 - 7856 - Loosen screws in each corner (4) using medium Phillips screwdriver, and open ...; Remark:7797
Procedure Step
Published
07/09/2023 12:04 AM
7795 - Caution : If you rotate cover of the SCA-775 down without first pulling out from the bo...
Annotation
Published
07/07/2023 2:23 PM
7856 - Loosen screws in each corner (4) using medium Phillips screwdriver, and open ...
Instruction
Published
07/09/2023 12:01 AM
7797 - Normally the cover screws are captured and should not come out of cover. ...
Remark
Published
07/07/2023 2:34 PM
9467 - To prevent breaking the hinge on the module / door, once the retainer screws ...
Remark
Published
10/03/2023 3:32 PM
7861 - 7859 - Remove 4 mounting screws; Remark:7860
Procedure Step
Published
07/09/2023 12:12 AM
7858 - Note : Most replaceable bit type screwdrivers will be too large in diameter to fit i...
Annotation
Published
07/09/2023 12:06 AM
7859 - Remove 4 mounting screws
Instruction
Published
07/09/2023 12:07 AM
7860 - The screws to be removed are located in the bottom of the irregularly shaped ...
Remark
Published
07/09/2023 12:11 AM
7863 - 7862 - Remove SCA-775 module from back plate; Remark:
Procedure Step
Published
07/09/2023 12:15 AM
7862 - Remove SCA-775 module from back plate
Instruction
Published
07/09/2023 12:14 AM
3397 - 3395 - Label faulty component; Remark:3396
Procedure Step
Published
07/21/2024 6:59 AM
3395 - Label faulty component
Instruction
Published
08/07/2021 11:07 AM
3396 - Use tag or tape. Include date of removal, description of failure symptoms, co...
Remark
Published
08/09/2021 11:35 AM
7865 - 7864 - Install New SCA-775 Module; Remark:
Procedure Step
Published
07/09/2023 12:18 AM
7864 - Install New SCA-775 Module
Instruction
Published
07/09/2023 12:18 AM
7868 - 7866 - Reinstall all four corner screws to mount replacement module; Remark:7867
Procedure Step
Published
07/09/2023 12:23 AM
7866 - Reinstall all four corner screws to mount replacement module
Instruction
Published
07/09/2023 12:20 AM
7867 - Install all screws loosely at first to facillitate easy mounting, then gently...
Remark
Published
07/09/2023 12:22 AM
7879 - 7878 - Reattach two connectors on bottom of SCA-775 module; Remark:7870
Procedure Step
Published
07/09/2023 1:16 AM
7878 - Reattach two connectors on bottom of SCA-775 module
Instruction
Published
07/09/2023 1:15 AM
7870 - The cable connectors are different sizes and keyed so they cannot be reinstal...
Remark
Published
07/09/2023 12:26 AM
7874 - 7872 - Reconnect BNC and MHV cables on top of SCA-775 module; Remark:7873
Procedure Step
Published
07/09/2023 12:31 AM
7811 - Caution : Proper connection of cables is critical.
Annotation
Published
07/07/2023 9:48 PM
7872 - Reconnect BNC and MHV cables on top of SCA-775 module
Instruction
Published
07/09/2023 12:30 AM
7873 - Verify each cable is connected to the appropriate connector.
Remark
Published
07/09/2023 12:31 AM
7837 - 7814 - Close SCA-775 module cover and tighten 4 screws; Remark:7815
Procedure Step
Published
07/07/2023 11:09 PM
7814 - Close SCA-775 module cover and tighten 4 screws
Instruction
Published
07/07/2023 9:50 PM
7815 - If the follow-on alignment and functional compliance test procedures are to b...
Remark
Published
07/07/2023 9:52 PM
7280 - 7250 - Power on RPM; Remark:7251
Procedure Step
Published
04/27/2023 4:14 PM
7250 - Power on RPM
Instruction
Published
05/01/2023 8:31 AM
7251 - Move LD-260 switch to ON position. The LED PWR ON
Remark
Published
05/10/2023 3:14 PM
7281 - 7252 - Verify RPM start-up; Remark:7253
Procedure Step
Published
04/20/2025 3:26 PM
7252 - Verify RPM start-up
Instruction
Published
04/27/2023 2:23 PM
7253 - RPM will perform a power on self-test (POST) and collect a background radiati...
Remark
Published
05/10/2023 3:14 PM
7279 - 7249 - Return equipment to normal operating condition; Remark:
Procedure Step
Published
04/27/2023 4:13 PM
7249 - Return equipment to normal operating condition
Instruction
Published
04/08/2025 3:22 PM
7840 - 7816 - Perform electronic alignment; Remark:7817
Procedure Step
Published
07/07/2023 11:12 PM
7816 - Perform electronic alignment
Instruction
Published
07/07/2023 9:55 PM
7817 - DET-RPM-RAP-CM01, RPM Electronic Alignment Procedure.
Remark
Published
04/13/2025 5:55 PM
7842 - 7820 - Inform system operators upon completion of maintenance action; Remark:
Procedure Step
Published
07/07/2023 11:15 PM
7820 - Inform system operators upon completion of maintenance action
Instruction
Published
07/07/2023 10:02 PM
322 - 321 - Document maintenance actions; Remark:
Procedure Step
Published
06/17/2021 9:49 AM
321 - Document maintenance actions
Instruction
Published
04/21/2025 11:19 AM
2869 - 2585 - Document maintenance performed; Remark:2866
Procedure Step
Published
06/18/2021 5:58 PM
2585 - Document maintenance performed
Instruction
Published
07/09/2021 12:15 PM
2866 - Record observations, times, and results for the maintenance report.
Remark
Published
04/21/2025 11:39 AM
4706 - 4705 - Submit report; Remark:4864
Procedure Step
Published
06/29/2022 9:50 AM
4705 - Submit report
Instruction
Published
06/29/2022 9:50 AM
4864 - As specified by management or contractual obligations.
Remark
Published
07/28/2022 1:36 PM
Corrective Maintenance Procedure
Document Type
Published
03/02/2020 3:32 PM
Upon failure of SCA-775 module
Frequency
Published
07/09/2023 12:50 AM
Warning
Annotation Type
Published
03/02/2020 3:25 PM
Note
Annotation Type
Published
03/02/2020 3:25 PM
Caution
Annotation Type
Published
03/02/2020 3:24 PM
Technician 1
Skill Level
Published
05/14/2020 2:56 PM
Keys to access RPM
Replacement Parts
Published
04/27/2023 6:56 PM
Reflective safety vest if required
Replacement Parts
Published
06/20/2023 4:47 PM
safety glasses
Replacement Parts
Published
07/02/2023 4:48 PM
Ladder; 2 meters, 6 feet tall; non-conducting if required
Replacement Parts
Published
07/02/2023 4:48 PM
Traffic control cones or equivalent if required
Replacement Parts
Published
06/20/2023 4:47 PM
Phillips screwdriver, medium
Replacement Parts
Published
07/07/2023 11:39 PM
Phillips screwdriver, small with 80 to 100 mm long shaft
Replacement Parts
Published
07/09/2023 1:06 AM
LD-260 Disconnect Switch Power Off
Image
Published
04/24/2023 12:49 PM
SCA-775 Two Connectors
Image
Published
07/08/2023 11:48 PM
SCA-775 BNC Connectors
Image
Published
07/08/2023 11:57 PM
Remove Six (6) Cover Screws
Image
Published
07/07/2023 2:27 PM
Cover screws are captured
Image
Published
10/04/2023 3:01 PM
To prevent breaking the hinge
Image
Published
10/04/2023 3:02 PM
SCA-775 Screw Sockets
Image
Published
07/09/2023 12:09 AM
LD-260 Disconnect Switch Power On
Image
Published
05/04/2023 3:37 PM