Last Updated: 04/23/2025 1:42 AM

The following table lists all the components that make up the document.

Title Type Status Last Updated
Rapiscan CM-267 Conveyor Monitor
Device
Published
06/27/2024 1:02 PM
Rapiscan PM-700 Pedestrian Monitor
Device
Published
06/20/2024 11:38 AM
Rapiscan TM-850 Rail Monitor
Device
Published
09/18/2024 10:28 AM
Rapiscan VM-250 Vehicle Monitor
Device
Published
10/14/2024 9:50 AM
7264 - 1401 - Establish Initial Conditions; Remark:
Procedure Step
Published
04/27/2023 7:00 PM
1401 - Establish Initial Conditions
Instruction
Published
09/30/2022 3:14 PM
7622 - 7592 - Inform system operators; Remark:11335
Procedure Step
Published
04/20/2025 10:15 AM
7592 - Inform system operators
Instruction
Published
06/29/2023 3:20 PM
11335 - Upon arrival, brief system operators on expected work, duration, anticipated ...
Remark
Published
04/20/2025 10:14 AM
7268 - 7231 - Close lane; Remark:7233
Procedure Step
Published
04/27/2023 7:01 PM
9053 - Warning : Traffic should temporarily be rerouted or halted during conduction of this pr...
Annotation
Published
09/27/2023 9:09 AM
7231 - Close lane
Instruction
Published
04/18/2023 1:00 PM
7233 - Use orange safety (traffic control) cones to setup barriers. Practice establi...
Remark
Published
04/24/2023 12:18 PM
7269 - 7232 - Open RPM door; Remark:7234
Procedure Step
Published
04/27/2023 7:02 PM
7232 - Open RPM door
Instruction
Published
04/18/2023 1:02 PM
7234 - Open all doors needed to access components.
Remark
Published
04/19/2025 7:48 PM
7755 - 7679 - Disconnect Ethernet; Remark:11336
Procedure Step
Published
04/20/2025 11:18 AM
7680 - Caution : Make sure to press release button on back of Ethernet cable before removing.
Annotation
Published
07/01/2023 11:54 PM
7679 - Disconnect Ethernet
Instruction
Published
07/01/2023 11:52 PM
11336 - Locate Ethernet connector on top of SC-770 controller. Press release button o...
Remark
Published
04/20/2025 11:21 AM
7270 - 7235 - Power off RPM; Remark:7236
Procedure Step
Published
09/01/2023 7:57 PM
7235 - Power off RPM
Instruction
Published
04/24/2023 12:30 PM
7236 - Move LD-260 switch to OFF position. The PWR ON
Remark
Published
04/27/2023 4:25 PM
9265 - 9223 - Remove PMFX Box; Remark:
Procedure Step
Published
10/02/2023 1:04 PM
9223 - Remove PMFX Box
Instruction
Published
10/03/2023 12:03 PM
9262 - 9224 - Disconnect all signal (BNC) and miniature high voltage (MHV) cables from PMFX...; Remark:
Procedure Step
Published
10/02/2023 1:04 PM
7792 - Note : It is good engineering practice to ensure all cables and connectors are label...
Annotation
Published
07/07/2023 2:17 PM
9224 - Disconnect all signal (BNC) and miniature high voltage (MHV) cables from PMFX...
Instruction
Published
10/02/2023 9:05 AM
9263 - 572 - Remove four (4) cover screws; Remark:9520
Procedure Step
Published
10/02/2023 1:05 PM
572 - Remove four (4) cover screws
Instruction
Published
08/09/2021 1:57 PM
9520 -
Remark
Published
10/04/2023 10:56 AM
9264 - 445 - Remove four (4) mounting screws; Remark:9232
Procedure Step
Published
10/02/2023 1:05 PM
445 - Remove four (4) mounting screws
Instruction
Published
07/22/2021 12:41 PM
9232 - Non-potted version
Remark
Published
10/03/2023 1:07 PM
9233 - Potted version
Remark
Published
10/03/2023 1:07 PM
9234 - Access holes for retaining screws.
Remark
Published
10/03/2023 1:06 PM
3397 - 3395 - Label faulty component; Remark:3396
Procedure Step
Published
07/21/2024 6:59 AM
3395 - Label faulty component
Instruction
Published
08/07/2021 11:07 AM
3396 - Use tag or tape. Include date of removal, description of failure symptoms, co...
Remark
Published
08/09/2021 11:35 AM
9261 - 9225 - Install New PMFX Box; Remark:
Procedure Step
Published
10/02/2023 1:06 PM
9225 - Install New PMFX Box
Instruction
Published
10/03/2023 12:05 PM
9257 - 9226 - Mount PMFX with four screws; Remark:7807
Procedure Step
Published
10/02/2023 1:06 PM
9226 - Mount PMFX with four screws
Instruction
Published
10/03/2023 12:04 PM
7807 - Use screws previously removed.
Remark
Published
07/07/2023 9:38 PM
9258 - 9227 - Reinstall four (4) cover screws; Remark:7807
Procedure Step
Published
10/02/2023 1:07 PM
9227 - Reinstall four (4) cover screws
Instruction
Published
10/02/2023 9:06 AM
9259 - 9228 - Reconnect BNC and MHV connectors to PMFX box; Remark:
Procedure Step
Published
10/02/2023 1:07 PM
9228 - Reconnect BNC and MHV connectors to PMFX box
Instruction
Published
10/02/2023 9:07 AM
7279 - 7249 - Return equipment to normal operating condition; Remark:
Procedure Step
Published
04/27/2023 4:13 PM
7249 - Return equipment to normal operating condition
Instruction
Published
04/08/2025 3:22 PM
7280 - 7250 - Power on RPM; Remark:7251
Procedure Step
Published
04/27/2023 4:14 PM
7250 - Power on RPM
Instruction
Published
05/01/2023 8:31 AM
7251 - Move LD-260 switch to ON position. The LED PWR ON
Remark
Published
05/10/2023 3:14 PM
9254 - 9229 - Verify neutron counts; Remark:9231
Procedure Step
Published
10/02/2023 1:09 PM
9229 - Verify neutron counts
Instruction
Published
10/02/2023 9:07 AM
9231 - Neutron counts can be verified by placing Cf-252 source near front of neutron...
Remark
Published
10/03/2023 1:13 PM
7781 - 7730 - Reconnect Ethernet; Remark:7731
Procedure Step
Published
04/20/2025 11:00 AM
7730 - Reconnect Ethernet
Instruction
Published
07/02/2023 2:34 AM
7731 - Insert Ethernet connector at top of SC-770 module. Connector will audibly "cl...
Remark
Published
07/02/2023 2:36 AM
7283 - 7256 - Close and lock all RPM doors; Remark:
Procedure Step
Published
09/01/2023 11:45 PM
7256 - Close and lock all RPM doors
Instruction
Published
04/27/2023 2:21 PM
9255 - 8250 - Reopen Lane; Remark:
Procedure Step
Published
10/02/2023 1:09 PM
8250 - Reopen Lane
Instruction
Published
09/07/2023 3:09 PM
7842 - 7820 - Inform system operators upon completion of maintenance action; Remark:
Procedure Step
Published
07/07/2023 11:15 PM
7820 - Inform system operators upon completion of maintenance action
Instruction
Published
07/07/2023 10:02 PM
322 - 321 - Document maintenance actions; Remark:
Procedure Step
Published
06/17/2021 9:49 AM
321 - Document maintenance actions
Instruction
Published
04/21/2025 11:19 AM
2869 - 2585 - Document maintenance performed; Remark:2866
Procedure Step
Published
06/18/2021 5:58 PM
2585 - Document maintenance performed
Instruction
Published
07/09/2021 12:15 PM
2866 - Record observations, times, and results for the maintenance report.
Remark
Published
04/21/2025 11:39 AM
4706 - 4705 - Submit report; Remark:4864
Procedure Step
Published
06/29/2022 9:50 AM
4705 - Submit report
Instruction
Published
06/29/2022 9:50 AM
4864 - As specified by management or contractual obligations.
Remark
Published
07/28/2022 1:36 PM
Corrective Maintenance Procedure
Document Type
Published
03/02/2020 3:32 PM
15 minutes
Duration
Published
04/01/2020 11:35 AM
Change from non-potted to potted parts once
Frequency
Published
10/02/2023 1:52 PM
Upon PMFX box failure
Frequency
Published
10/02/2023 1:51 PM
Warning
Annotation Type
Published
03/02/2020 3:25 PM
Caution
Annotation Type
Published
03/02/2020 3:24 PM
Note
Annotation Type
Published
03/02/2020 3:25 PM
Technician 1
Skill Level
Published
05/14/2020 2:56 PM
Medium Phillips (PH2) screwdriver bit
Tools
Published
07/01/2022 11:18 AM
Phillips screwdriver, small with 80 to 100 mm long shaft
Replacement Parts
Published
07/09/2023 1:06 AM
Disconnect Ethernet cable on top of SC-770 box
Image
Published
10/04/2023 2:59 PM
LD-260 Disconnect Switch Power Off
Image
Published
04/24/2023 12:49 PM
Remove four (4) cover Screws
Image
Published
10/02/2023 3:09 PM
non-potted version
Image
Published
10/02/2023 3:10 PM
potted version. Access holes for retaining screws.
Image
Published
10/02/2023 3:12 PM
LD-260 Disconnect Switch Power On
Image
Published
05/04/2023 3:37 PM
DET-RPM-RAP-CM04

Replace PMFX Box. 

Equipment Hierarchy
Rapiscan CM-267 Conveyor Monitor
Rapiscan PM-700 Pedestrian Monitor
Rapiscan TM-850 Rail Monitor
Rapiscan VM-250 Vehicle Monitor
Frequency
Change from non-potted to potted parts once
Upon PMFX box failure
Technician Level
Technician Level
Technician 1
x 1
Duration
Time increment
15 minutes
Length of time
15
Tools Required
Medium Phillips (PH2) screwdriver bit
Phillips screwdriver, small with 80 to 100 mm long shaft
Materials Required
Neutron Signal Pick-off Box (Rapiscan Part# 8699P)
Originators
Craig Stinson
Bailey Toon
Originating Organization
PNNL
Approver
Eric Hirschi
Safety Concerns
Traffic
Final Documentation
Corrective maintenance report
Departmental Coordination

Prior to arrival, notify operators concerning expected work, duration, and anticipated alarms and fault indications. 

Date of Origin
Version
0.00
Preparation
Step 1

7268 - 7231 - Close lane; Remark:7233

Step 00
Operation
Step 2
Operation
Step 4

9254 - 9229 - Verify neutron counts; Remark:9231

Step 00

9231 - Neutron counts can be verified by placing Cf-252 source near front of neutron...

Neutron counts can be verified by placing Cf-252 source near front of neutron detector and observing the SHOW COUNTS or by observing the SHOW COUNTS until there is a value other than “0.”

To access neutron SHOW COUNTS:

Enter Program Mode by pressing “0.”

Enter the password 1234 and press “#” (enter); press:

2: NEUTRON

            2: FUNCTIONS

                        1: SHOW COUNTS

Document Type
Corrective Maintenance Procedure
Percent Complete
100.00
Percent Complete W/Media
100.00