The following table lists all the components that make up the document.

Title Type Status Last Updated
Rapiscan CM-267 Conveyor Monitor
Device
Published
06/27/2024 1:02 PM
Rapiscan PM-700 Pedestrian Monitor
Device
Published
06/20/2024 11:38 AM
Rapiscan TM-850 Rail Monitor
Device
Published
09/18/2024 10:28 AM
Rapiscan VM-250 Vehicle Monitor
Device
Published
10/14/2024 9:50 AM
1402 - 7927 - Establish Initial Conditions; Remark:
Procedure Step
Published
09/30/2022 1:47 PM
7927 - Establish Initial Conditions
Instruction
Published
07/12/2023 12:23 AM
7977 - 7592 - Inform system operators; Remark:7976
Procedure Step
Published
07/24/2023 9:53 AM
7592 - Inform system operators
Instruction
Published
06/29/2023 3:20 PM
7976 - Operators should expect to receive fault and alarm indications during perform...
Remark
Published
07/24/2023 9:53 AM
7983 - 7981 - Inspect for any physical damage or rodent/insect infestation; Remark:
Procedure Step
Published
07/26/2023 2:45 PM
7982 - Note : Document each step and verification on attached checklist
Annotation
Published
07/26/2023 2:45 PM
7981 - Inspect for any physical damage or rodent/insect infestation
Instruction
Published
07/26/2023 2:44 PM
7984 - 7980 - Close lane and set up barriers or establish a safety watch; Remark:7595
Procedure Step
Published
07/26/2023 2:47 PM
7678 - Warning : Traffic should temporarily be rerouted or halted during conduction of this pr...
Annotation
Published
07/03/2023 10:23 AM
7980 - Close lane and set up barriers or establish a safety watch
Instruction
Published
07/26/2023 2:46 PM
7595 - Use orange safety (traffic control) cones or equivalent per site-specific saf...
Remark
Published
06/29/2023 3:33 PM
7280 - 7250 - Power on RPM; Remark:7251
Procedure Step
Published
04/27/2023 4:14 PM
7250 - Power on RPM
Instruction
Published
05/01/2023 8:31 AM
7251 - Move LD-260 switch to ON position. The LED PWR ON
Remark
Published
05/10/2023 3:14 PM
7997 - 7995 - Disable RPM occupancy sensors; Remark:7994
Procedure Step
Published
07/26/2023 3:08 PM
7995 - Disable RPM occupancy sensors
Instruction
Published
07/26/2023 3:07 PM
7994 - “Relays” Parameter in SC-770 controller must be set to “ON.” Audible ...
Remark
Published
07/26/2023 3:07 PM
7993 - 7992 - Test Gamma Radiation Detection; Remark:
Procedure Step
Published
07/26/2023 3:33 PM
7992 - Test Gamma Radiation Detection
Instruction
Published
07/26/2023 3:33 PM
7989 - 7988 - Initiate and maintain occupancy by interrupting beam of occupancy sensor ...; Remark:
Procedure Step
Published
07/26/2023 3:37 PM
7988 - Initiate and maintain occupancy by interrupting beam of occupancy sensor ...
Instruction
Published
07/26/2023 3:34 PM
7990 - 7987 - Hold Cs-137 source, Co-57 source, or both near front of either gamma detector...; Remark:
Procedure Step
Published
07/26/2023 3:38 PM
7987 - Hold Cs-137 source, Co-57 source, or both near front of either gamma detector...
Instruction
Published
07/26/2023 3:38 PM
7991 - 7986 - Verify red strobe and audible indications function; Remark:7985
Procedure Step
Published
07/26/2023 3:38 PM
7986 - Verify red strobe and audible indications function
Instruction
Published
07/26/2023 3:38 PM
7985 - On SC-770 controller On the control pillar door
Remark
Published
07/26/2023 3:39 PM
8006 - 8004 - Remove Cs-137 source, Co-57 source, or both from detector; Remark:
Procedure Step
Published
07/26/2023 3:45 PM
8005 - Note : Move the source at least 10m from the detectors.
Annotation
Published
07/26/2023 3:45 PM
8004 - Remove Cs-137 source, Co-57 source, or both from detector
Instruction
Published
07/26/2023 3:45 PM
8007 - 8003 - Wait at least 30 seconds for background average to stabilize; Remark:
Procedure Step
Published
07/26/2023 3:46 PM
8003 - Wait at least 30 seconds for background average to stabilize
Instruction
Published
07/26/2023 3:46 PM
8008 - 8002 - Initiate a gamma hi background fault by holding Cs-137 source, Co 57 source, ...; Remark:
Procedure Step
Published
07/26/2023 3:47 PM
8002 - Initiate a gamma hi background fault by holding Cs-137 source, Co 57 source, ...
Instruction
Published
07/26/2023 3:47 PM
8009 - 8001 - Verify amber fault LED indication functions; Remark:8000
Procedure Step
Published
07/26/2023 3:49 PM
8001 - Verify amber fault LED indication functions
Instruction
Published
07/26/2023 3:48 PM
8000 - On SC-770 controller On the control pillar door
Remark
Published
04/13/2025 5:56 PM
8010 - 7998 - Remove Cs-137 source, Co-57 source, or both from detector; Remark:
Procedure Step
Published
07/26/2023 3:52 PM
7999 - Note : Move the source at least 10m from the detectors.
Annotation
Published
07/26/2023 3:52 PM
7998 - Remove Cs-137 source, Co-57 source, or both from detector
Instruction
Published
07/26/2023 3:51 PM
8015 - 8014 - Wait at least 30 seconds for background average to stabilize; Remark:
Procedure Step
Published
07/26/2023 3:54 PM
8014 - Wait at least 30 seconds for background average to stabilize
Instruction
Published
07/26/2023 3:54 PM
8016 - 8012 - Disconnect BNC signal cable from any gamma detector to initiate a gamma lo ba...; Remark:8011
Procedure Step
Published
07/26/2023 3:55 PM
8013 - Note : Occupancy sensors must be disabled during testing of fault indications.
Annotation
Published
07/26/2023 3:56 PM
8012 - Disconnect BNC signal cable from any gamma detector to initiate a gamma lo ba...
Instruction
Published
07/26/2023 3:54 PM
8011 - This can be done on the detector itself or at the SCA‐775 box.
Remark
Published
07/26/2023 3:55 PM
8030 - 8001 - Verify amber fault LED indication functions; Remark:7985
Procedure Step
Published
07/26/2023 4:18 PM
8031 - 8003 - Wait at least 30 seconds for background average to stabilize; Remark:
Procedure Step
Published
07/26/2023 4:19 PM
8032 - 8029 - Reconnect BNC signal cable from step 2-10; Remark:
Procedure Step
Published
07/26/2023 4:20 PM
8029 - Reconnect BNC signal cable from step 2-10
Instruction
Published
07/26/2023 4:19 PM
8028 - 8027 - Test Neutron Radiation Detection; Remark:
Procedure Step
Published
07/26/2023 4:21 PM
8027 - Test Neutron Radiation Detection
Instruction
Published
07/26/2023 4:21 PM
8022 - 7988 - Initiate and maintain occupancy by interrupting beam of occupancy sensor ...; Remark:
Procedure Step
Published
07/26/2023 4:22 PM
8021 - Note : Because CF-252 sources also emit gamma radiation, a gamma alarm may also occu...
Annotation
Published
07/26/2023 4:22 PM
8023 - 8020 - Hold Cf-252 source near front of neutron detector; Remark:
Procedure Step
Published
07/26/2023 4:23 PM
8020 - Hold Cf-252 source near front of neutron detector
Instruction
Published
07/26/2023 4:23 PM
8024 - 8019 - Verify blue strobe and audible indication functions; Remark:7985
Procedure Step
Published
07/26/2023 4:27 PM
8019 - Verify blue strobe and audible indication functions
Instruction
Published
07/26/2023 4:24 PM
8025 - 8018 - Remove Cf-252 source from detector; Remark:
Procedure Step
Published
07/26/2023 4:29 PM
8018 - Remove Cf-252 source from detector
Instruction
Published
07/26/2023 4:28 PM
8026 - 8017 - Wait at least 2 minutes for background average to stabilize; Remark:
Procedure Step
Published
07/26/2023 4:30 PM
8017 - Wait at least 2 minutes for background average to stabilize
Instruction
Published
07/26/2023 4:30 PM
8035 - 8033 - Initiate a neutron hi background fault by holding Cf‐252 source near front ...; Remark:
Procedure Step
Published
07/26/2023 4:32 PM
8034 - Note : A gamma hi fault may also occur during this step. If this is unacceptable, ei...
Annotation
Published
07/26/2023 4:32 PM
8033 - Initiate a neutron hi background fault by holding Cf‐252 source near front ...
Instruction
Published
07/26/2023 4:32 PM
8036 - 8001 - Verify amber fault LED indication functions; Remark:7985
Procedure Step
Published
07/26/2023 4:33 PM
8037 - 8018 - Remove Cf-252 source from detector; Remark:
Procedure Step
Published
07/26/2023 4:34 PM
8044 - 8043 - Test Tamper Fault Circuitry; Remark:
Procedure Step
Published
07/27/2023 8:54 AM
8043 - Test Tamper Fault Circuitry
Instruction
Published
07/27/2023 8:50 AM
8041 - 8040 - Disconnect the AC power supplied to the portal monitor to initiate a “Loss ...; Remark:8039
Procedure Step
Published
07/27/2023 8:57 AM
8040 - Disconnect the AC power supplied to the portal monitor to initiate a “Loss ...
Instruction
Published
07/27/2023 8:55 AM
8039 - 1.If RPM breaker in associated utility panel is marked: Open the RPMs dedicat...
Remark
Published
07/27/2023 8:57 AM
8042 - 8038 - Re-energize RPM, remove magnet from door switch, close cabinet door, and allo...; Remark:
Procedure Step
Published
07/27/2023 8:58 AM
8038 - Re-energize RPM, remove magnet from door switch, close cabinet door, and allo...
Instruction
Published
07/27/2023 8:58 AM
8051 - 8050 - Initiate a cabinet open tamper fault; Remark:
Procedure Step
Published
07/27/2023 9:00 AM
8050 - Initiate a cabinet open tamper fault
Instruction
Published
07/27/2023 9:00 AM
7842 - 7820 - Inform system operators upon completion of maintenance action; Remark:
Procedure Step
Published
07/07/2023 11:15 PM
7820 - Inform system operators upon completion of maintenance action
Instruction
Published
07/07/2023 10:02 PM
253 - 242 - Document and report any unresolved problems; Remark:
Procedure Step
Published
06/22/2021 10:23 AM
242 - Document and report any unresolved problems
Instruction
Published
04/21/2025 11:45 AM
Routine Maintenance Procedure
Document Type
Published
03/02/2020 3:31 PM
10 minutes
Duration
Published
04/01/2020 11:35 AM
Quarterly
Frequency
Published
08/02/2020 10:39 PM
Note
Annotation Type
Published
03/02/2020 3:25 PM
Warning
Annotation Type
Published
03/02/2020 3:25 PM
Technician 1
Skill Level
Published
05/14/2020 2:56 PM
Keys to access RPM
Replacement Parts
Published
04/27/2023 6:56 PM
Reflective safety vest if required
Replacement Parts
Published
06/20/2023 4:47 PM
Traffic control cones or equivalent if required
Replacement Parts
Published
06/20/2023 4:47 PM
Magnet
Replacement Parts
Published
07/24/2023 9:53 AM
LD-260 Disconnect Switch Power On
Image
Published
05/04/2023 3:37 PM
DET-RPM-RAP-RM03

Operational testing of Rapiscan radiation portal monitor (RPM)

Equipment Hierarchy
Rapiscan CM-267 Conveyor Monitor
Rapiscan PM-700 Pedestrian Monitor
Rapiscan TM-850 Rail Monitor
Rapiscan VM-250 Vehicle Monitor
Frequency
Quarterly
Technician Level
Technician Level
Technician 1
x 1
Duration
Time increment
10 minutes
Length of time
10
Tools Required
Keys to access RPM
Reflective safety vest if required
Traffic control cones or equivalent if required
Magnet
Materials Required
NSDD Radioactive Check Source Suite
Originators
Craig Stinson
Bailey Toon
Originating Organization
PNNL
Approver
Craig Stinson
Safety Concerns
Radioactive Source
Vehicle traffic
Final Documentation
Routine maintenance report with operation checklist
Departmental Coordination

Coordinate site access with system operators

Date of Origin
Version
1.00
Version #
Revision Description

Radioactive source; vehicle traffic

Revision Date
Revision Author
Preparation
Step 1

7984 - 7980 - Close lane and set up barriers or establish a safety watch; Remark:7595

Step 00
Operation
Step 2

8016 - 8012 - Disconnect BNC signal cable from any gamma detector to initiate a gamma lo ba...; Remark:8011

Step 00
Step 3

8022 - 7988 - Initiate and maintain occupancy by interrupting beam of occupancy sensor ...; Remark:

8021 - Note : Because CF-252 sources also emit gamma radiation, a gamma alarm may also occu...

Type
Note

Because CF-252 sources also emit gamma radiation, a gamma alarm may also occur during this step. If this is unacceptable, either shield the gamma radiation emitted from the source with lead or hold the Cf-252 source near a neutron detector from behind the skid. The lead (Pb) shielding on the back of gamma detectors will help reduce the possibility of a gamma alarm during this step.

Step 00

8035 - 8033 - Initiate a neutron hi background fault by holding Cf‐252 source near front ...; Remark:

Step 00
Step 4

8041 - 8040 - Disconnect the AC power supplied to the portal monitor to initiate a “Loss ...; Remark:8039

Step 00
Document Type
Routine Maintenance Procedure
Percent Complete
100.00
Percent Complete W/Media
100.00