786 - 219 - Verify there are no sources of radiation near instrument; Remark:7 |
Procedure Step
|
Published
|
04/20/2025 6:37 PM
|
219 - Verify there are no sources of radiation near instrument |
Instruction
|
Published
|
04/12/2025 4:20 PM
|
7 - No Radiation symbol |
Remark
|
Published
|
07/12/2021 1:34 PM
|
139 - 220 - Power on instrument; Remark:2545 |
Procedure Step
|
Published
|
04/20/2025 9:47 PM
|
220 - Power on instrument |
Instruction
|
Published
|
04/06/2025 7:00 PM
|
2545 - IO PRM-470 Power Button Red Box |
Remark
|
Published
|
10/29/2024 9:30 PM
|
679 - 612 - Wait for instrument to complete start-up sequence; Remark: |
Procedure Step
|
Published
|
04/13/2025 6:33 PM
|
612 - Wait for instrument to complete start-up sequence |
Instruction
|
Published
|
04/13/2025 6:38 PM
|
3085 - 3077 - SELECT mode; Remark:10470 |
Procedure Step
|
Published
|
07/12/2021 1:41 PM
|
3077 - SELECT mode |
Instruction
|
Published
|
07/12/2021 1:31 PM
|
10470 - |
Remark
|
Published
|
12/01/2023 4:48 PM
|
3086 - 3078 - VERIFY instrument is in SEARCH MODE; Remark:751 |
Procedure Step
|
Published
|
07/12/2021 1:41 PM
|
3078 - VERIFY instrument is in SEARCH MODE |
Instruction
|
Published
|
07/12/2021 1:30 PM
|
751 - IO PRM-470 Search Mode 65 CPS Gamma |
Remark
|
Published
|
10/29/2024 9:31 PM
|
131 - 115 - SURVEY close to surface of item (5-10 centimeters); Remark:10467 |
Procedure Step
|
Published
|
07/12/2021 1:42 PM
|
115 - SURVEY close to surface of item (5-10 centimeters) |
Instruction
|
Published
|
06/13/2022 11:23 AM
|
10467 - |
Remark
|
Published
|
12/01/2023 4:53 PM
|
3087 - 617 - SURVEY SLOWLY over entire item (20 centimeters/second); Remark: |
Procedure Step
|
Published
|
07/12/2021 1:42 PM
|
617 - SURVEY SLOWLY over entire item (20 centimeters/second) |
Instruction
|
Published
|
06/06/2022 12:17 PM
|
3088 - 3079 - CHANGE to FIND MODE when alarm is constant; Remark:3082 |
Procedure Step
|
Published
|
07/12/2021 1:43 PM
|
3079 - CHANGE to FIND MODE when alarm is constant |
Instruction
|
Published
|
07/12/2021 1:28 PM
|
3082 - IO PRM-470 Mode Button Red Box |
Remark
|
Published
|
10/29/2024 9:32 PM
|
3089 - 3080 - OBSERVE instrument response; Remark:10461 |
Procedure Step
|
Published
|
07/12/2021 1:43 PM
|
3080 - OBSERVE instrument response |
Instruction
|
Published
|
07/12/2021 1:27 PM
|
10461 - |
Remark
|
Published
|
12/01/2023 5:04 PM
|
133 - 368 - Mark point(s) of interest; Remark:132 |
Procedure Step
|
Published
|
04/20/2025 6:28 PM
|
368 - Mark point(s) of interest |
Instruction
|
Published
|
06/11/2021 9:23 AM
|
132 - Marking location for further investigation |
Remark
|
Published
|
11/09/2024 3:37 PM
|
136 - 117 - DOCUMENT results; Remark: |
Procedure Step
|
Published
|
07/12/2021 1:44 PM
|
117 - DOCUMENT results |
Instruction
|
Published
|
07/12/2021 1:26 PM
|
3090 - 313 - Power off instrument; Remark:2545 |
Procedure Step
|
Published
|
01/14/2022 5:30 PM
|
313 - Power off instrument |
Instruction
|
Published
|
07/23/2021 2:41 PM
|
120 - Reminder : It is recommended to perform an operational test daily before use. DET-HHD-RA... |
Annotation
|
Published
|
07/12/2021 1:23 PM
|
121 - Reminder : If instrument does not move for 60 seconds, it will switch to background mode... |
Annotation
|
Published
|
07/12/2021 1:22 PM
|
3075 - Reminder : Do not operate the instrument at temperatures lower than 0°C or higher than ... |
Annotation
|
Published
|
07/12/2021 1:21 PM
|
3076 - Reminder : Power off instrument prior to connecting to charger. |
Annotation
|
Published
|
07/12/2021 1:20 PM
|
Pocket Guide |
Document Type
|
Published
|
03/02/2020 3:32 PM
|
Reminder |
Annotation Type
|
Published
|
04/08/2020 12:21 PM
|
No Radiation Symbol |
රූපය
|
Published
|
08/13/2024 2:56 PM
|
PRM-470_Partial_Power_Button_Red_Highlight.png |
රූපය
|
Published
|
06/18/2021 6:28 PM
|
Rapiscan PRM-470 CGN Select Mode |
රූපය
|
Published
|
12/01/2023 5:15 PM
|
PRM-470 Display SEARCH |
රූපය
|
Published
|
04/01/2021 11:22 PM
|
Rapiscan PRM-470 CGN survey close to surface |
රූපය
|
Published
|
12/01/2023 5:15 PM
|
PRM-470_Partial-View_S-F-Button_RED-Highlight.png |
රූපය
|
Published
|
04/01/2021 11:22 PM
|
Rapiscan PRM-470 CGN Instrument response Find Mode |
රූපය
|
Published
|
12/01/2023 5:15 PM
|
Mark_Source_Location_Trefoil |
රූපය
|
Published
|
02/19/2023 10:54 AM
|