Abbreviation
OP

RadEye PRD-ER Operation

Last Updated: 05/04/2025 1:39 AM

The following table lists all the components that make up the document.

Title Type Status Last Updated
Thermo RadEye PRD-ER
Device
Published
06/27/2024 11:19 AM
247 - 257 - Prepare instrument; Remark:
Procedure Step
Published
04/11/2025 9:08 PM
257 - Prepare instrument
Instruction
Published
04/11/2025 9:07 PM
786 - 219 - Verify there are no sources of radiation near instrument; Remark:7
Procedure Step
Published
04/20/2025 6:37 PM
219 - Verify there are no sources of radiation near instrument
Instruction
Published
04/12/2025 4:20 PM
7 - No Radiation symbol
Remark
Published
07/12/2021 1:34 PM
4937 - 220 - Power on instrument; Remark:4936
Procedure Step
Published
08/19/2022 2:47 PM
220 - Power on instrument
Instruction
Published
04/06/2025 7:00 PM
4936 - Press “On” button until beeper sounds.
Remark
Published
08/19/2022 1:21 PM
4938 - 612 - Wait for instrument to complete start-up sequence; Remark:4935
Procedure Step
Published
04/13/2025 6:50 PM
612 - Wait for instrument to complete start-up sequence
Instruction
Published
04/13/2025 6:38 PM
4935 - Screen will display “Learning” until initial startup is ...
Remark
Published
08/19/2022 1:23 PM
4939 - 2295 - Verify sufficient battery charge; Remark:4934
Procedure Step
Published
08/19/2022 2:48 PM
2295 - Verify sufficient battery charge
Instruction
Published
04/06/2021 4:43 PM
4934 - Connect the instrument to the charger if necessary.
Remark
Published
08/19/2022 1:25 PM
4933 - 4932 - Enable or Disable Audio Alarm; Remark:
Procedure Step
Published
08/19/2022 1:26 PM
1108 - Note : In noisy environments, use visual and vibration alarms when audio alarms cann...
Annotation
Published
06/09/2020 5:59 PM
4932 - Enable or Disable Audio Alarm
Instruction
Published
08/19/2022 1:26 PM
4952 - 4951 - Press left arrow for “Menu”; Remark:
Procedure Step
Published
08/19/2022 1:36 PM
4951 - Press left arrow for “Menu”
Instruction
Published
08/19/2022 1:36 PM
4953 - 4950 - Scroll to “Sound”; Remark:4949
Procedure Step
Published
08/19/2022 1:37 PM
4950 - Scroll to “Sound”
Instruction
Published
08/19/2022 1:36 PM
4949 - Use up/down arrows to scroll.
Remark
Published
08/19/2022 1:37 PM
4954 - 4948 - Press left arrow to toggle sound on or off; Remark:4947
Procedure Step
Published
08/19/2022 1:38 PM
4948 - Press left arrow to toggle sound on or off
Instruction
Published
08/19/2022 1:37 PM
4947 - The audio alarm is enabled when there is a check mark next to “Soun...
Remark
Published
08/19/2022 1:38 PM
4955 - 4946 - Press right arrow to exit; Remark:
Procedure Step
Published
08/19/2022 1:39 PM
4946 - Press right arrow to exit
Instruction
Published
08/19/2022 1:39 PM
4931 - 4930 - Enable or Disable Vibration Alarm; Remark:
Procedure Step
Published
08/19/2022 1:26 PM
4930 - Enable or Disable Vibration Alarm
Instruction
Published
08/19/2022 1:26 PM
4944 - 4943 - Scroll to “Vibrator”; Remark:
Procedure Step
Published
08/19/2022 1:40 PM
4943 - Scroll to “Vibrator”
Instruction
Published
08/19/2022 1:39 PM
4945 - 4942 - Press left arrow to toggle vibration on or off; Remark:4941
Procedure Step
Published
08/19/2022 1:41 PM
4942 - Press left arrow to toggle vibration on or off
Instruction
Published
08/19/2022 1:40 PM
4941 - The vibration alarm is enabled when there is a check mark next to “...
Remark
Published
08/19/2022 1:41 PM
4929 - 4928 - Check against known radioactive source (if available); Remark:4927
Procedure Step
Published
08/19/2022 1:32 PM
4928 - Check against known radioactive source (if available)
Instruction
Published
08/19/2022 1:28 PM
4927 - When a source is detected, the light flashes, the alarm sounds (if enabled), ...
Remark
Published
08/19/2022 1:29 PM
4926 - 2904 - Wear instrument during shift; Remark:4925
Procedure Step
Published
08/19/2022 1:30 PM
4960 - Caution : The instrument is designed to operate at temperatures between -20°C and 50°...
Annotation
Published
08/19/2022 1:44 PM
1105 - Note : Wear the instrument at all times while on duty.
Annotation
Published
06/09/2020 5:55 PM
4961 - Note : Do not use the instrument if error messages appear on the screen.
Annotation
Published
08/19/2022 1:45 PM
2904 - Wear instrument during shift
Instruction
Published
06/15/2021 9:00 AM
4925 - Place instrument in its protective sleeve and attach the instrument to clothi...
Remark
Published
08/19/2022 1:30 PM
1099 - 1096 - Respond to alarms; Remark:
Procedure Step
Published
06/09/2020 6:13 PM
1106 - Caution : Do not operate the instrument at temperatures lower than -20°C, higher than ...
Annotation
Published
06/09/2020 5:56 PM
1104 - Note : The instrument is highly sensitive to changes in ambient background radiation...
Annotation
Published
06/09/2020 5:55 PM
1103 - Note : When in use, do not keep instrument near radio-emitting sources (e.g., cell p...
Annotation
Published
06/09/2020 5:54 PM
1096 - Respond to alarms
Instruction
Published
06/15/2021 9:00 AM
4958 - 2357 - Acknowledge alarms; Remark:4957
Procedure Step
Published
08/19/2022 1:47 PM
2357 - Acknowledge alarms
Instruction
Published
07/23/2021 9:29 PM
4957 - Press the right arrow to silence an alarm.
Remark
Published
08/19/2022 1:47 PM
4959 - 1098 - Verify dose rate is below allowable rate for site; Remark:4956
Procedure Step
Published
08/19/2022 1:49 PM
1098 - Verify dose rate is below allowable rate for site
Instruction
Published
06/09/2020 5:50 PM
4956 - The allowable dose rate is site dependent and should be indicated in the stan...
Remark
Published
08/19/2022 1:49 PM
260 - 313 - Power off instrument; Remark:
Procedure Step
Published
07/23/2021 2:43 PM
313 - Power off instrument
Instruction
Published
07/23/2021 2:41 PM
4967 - 4951 - Press left arrow for “Menu”; Remark:4966
Procedure Step
Published
08/19/2022 2:49 PM
4966 - IO RadEye Menu Button Alone
Remark
Published
08/19/2022 2:08 PM
4968 - 313 - Power off instrument; Remark:4964
Procedure Step
Published
04/07/2025 4:23 PM
4964 - Use up/down arrows to scroll. Use the left arrow to select Switch Off...
Remark
Published
08/19/2022 2:10 PM
4969 - 4963 - Press left arrow to select “Yes”; Remark:4962
Procedure Step
Published
08/19/2022 2:51 PM
4963 - Press left arrow to select “Yes”
Instruction
Published
08/19/2022 2:12 PM
4962 - IO RadEye Power Off Yes Selection
Remark
Published
08/19/2022 2:12 PM
Operator Procedure
Document Type
Published
03/02/2020 3:31 PM
Note
Annotation Type
Published
03/02/2020 3:25 PM
Caution
Annotation Type
Published
03/02/2020 3:24 PM
No Radiation Symbol
Imagine
Published
08/13/2024 2:56 PM
IO RadEye Button Power On
Imagine
Published
08/18/2022 2:16 PM
RadEye Start-up Learning
Imagine
Published
08/18/2022 4:51 PM
RadEye Battery Level
Imagine
Published
08/18/2022 4:56 PM
RadEye Menu with Sound Checked
Imagine
Published
08/19/2022 11:49 AM
RadEye Menu with Vibraator Checked
Imagine
Published
08/19/2022 11:51 AM
RadEye Alarm Red Audio Icon
Imagine
Published
08/19/2022 11:42 AM
RadEye Operator Wear Belt
Imagine
Published
08/18/2022 5:03 PM
RadEye Alarm Acknowledge Right Button
Imagine
Published
08/19/2022 11:45 AM
RadEye Menu Button Left Arrow
Imagine
Published
08/18/2022 5:32 PM
RadEye Menu with Switch off Red Box
Imagine
Published
08/19/2022 11:53 AM
RadEye Power Off Confirm Question
Imagine
Published
08/19/2022 11:55 AM