Last Updated: 05/01/2025 1:39 AM

The following table lists all the components that make up the document.

Title Type Status Last Updated
FLIR identiFINDER 2 NG
Device
Published
10/24/2024 10:14 AM
3128 - 3127 - Carefully DISCONNECT from external charger; Remark:3126
Procedure Step
Published
07/19/2021 2:48 PM
3127 - Carefully DISCONNECT from external charger
Instruction
Published
07/19/2021 2:46 PM
3126 - Disconnect IDF2 from external charger
Remark
Published
05/24/2021 7:49 PM
3130 - 3129 - SECURE safety strap on wrist; Remark:
Procedure Step
Published
07/19/2021 2:49 PM
3129 - SECURE safety strap on wrist
Instruction
Published
10/07/2022 10:53 AM
786 - 219 - Переконайтеся, що поряд з приладом немає радіоактивних джерел.; Remark:7
Procedure Step
Published
04/20/2025 6:37 PM
219 - Verify there are no sources of radiation near instrument
Instruction
Published
04/12/2025 4:20 PM
7 - No Radiation symbol
Remark
Published
07/12/2021 1:34 PM
3136 - 220 - Power on instrument; Remark:3134
Procedure Step
Published
04/20/2025 9:46 PM
220 - Power on instrument
Instruction
Published
04/06/2025 7:00 PM
3134 - IdentiFINDER2-NG Power On
Remark
Published
05/03/2021 3:18 PM
679 - 612 - ЗАЧЕКАЙТЕ , поки прилад завершить процес запуску.; Remark:
Procedure Step
Published
04/13/2025 6:33 PM
612 - Wait for instrument to complete start-up sequence
Instruction
Published
04/13/2025 6:38 PM
3141 - 3140 - VERIFY sufficient battery power; Remark:3139
Procedure Step
Published
07/19/2021 2:50 PM
3140 - VERIFY sufficient battery power
Instruction
Published
10/07/2022 12:55 PM
3139 - IdentiFINDER2-NG Battery Level Icon
Remark
Published
05/03/2021 3:31 PM
3390 - 3142 - CHECK operation with a known source if available; Remark:
Procedure Step
Published
07/19/2021 2:51 PM
3142 - CHECK operation with a known source if available
Instruction
Published
10/07/2022 12:41 PM
2180 - 2150 - VERIFY instrument is in a suitable area to collect backgroun...; Remark:
Procedure Step
Published
07/19/2021 2:51 PM
2150 - VERIFY instrument is in a suitable area to collect backgroun...
Instruction
Published
07/19/2021 2:40 PM
3145 - 3144 - PRESS L to enter Finder mode; Remark:3143
Procedure Step
Published
07/19/2021 2:52 PM
3144 - PRESS L to enter Finder mode
Instruction
Published
07/19/2021 2:39 PM
3143 - Press L to enter Finder mode
Remark
Published
05/03/2021 3:57 PM
3147 - 3146 - WAIT for 10-second background measurement to finish; Remark:
Procedure Step
Published
07/19/2021 2:52 PM
3146 - WAIT for 10-second background measurement to finish
Instruction
Published
10/07/2022 12:43 PM
3150 - 3149 - SEARCH entire area of interest; Remark:3148
Procedure Step
Published
07/19/2021 2:53 PM
3149 - SEARCH entire area of interest
Instruction
Published
10/07/2022 12:44 PM
3148 - Identifinder2-NG Search Pattern
Remark
Published
05/03/2021 4:04 PM
3153 - 923 - OBSERVE instrument response for elevated radiation levels; Remark:3151
Procedure Step
Published
06/09/2022 1:19 PM
923 - OBSERVE instrument response for elevated radiation levels
Instruction
Published
10/07/2022 12:46 PM
3151 - Identifinder2-NG Gamma level graph display
Remark
Published
05/03/2021 4:09 PM
3156 - 3155 - CHARACTERIZE distribution of radiation; Remark:3154
Procedure Step
Published
07/19/2021 2:53 PM
3155 - CHARACTERIZE distribution of radiation
Instruction
Published
07/19/2021 2:37 PM
3154 - Identifinder2-NG Dose Rate Display - Press M
Remark
Published
05/03/2021 4:13 PM
133 - 368 - Позначити місце або місця, які потребують ...; Remark:132
Procedure Step
Published
04/20/2025 6:28 PM
368 - Mark point(s) of interest
Instruction
Published
06/11/2021 9:23 AM
132 - Marking location for further investigation
Remark
Published
11/09/2024 3:37 PM
3161 - 3160 - DOCUMENT search results; Remark:
Procedure Step
Published
05/28/2021 9:53 AM
3160 - DOCUMENT search results
Instruction
Published
10/07/2022 12:48 PM
3163 - 3162 - POSITION instrument at marked location; Remark:
Procedure Step
Published
07/19/2021 2:55 PM
3162 - POSITION instrument at marked location
Instruction
Published
10/07/2022 12:49 PM
3166 - 3165 - PRESS M to enter IDENT mode; Remark:3164
Procedure Step
Published
07/19/2021 2:55 PM
3165 - PRESS M to enter IDENT mode
Instruction
Published
10/07/2022 12:50 PM
3164 - Identifinder2-NG Press M to enter IDENT mode
Remark
Published
05/03/2021 4:48 PM
3170 - 3168 - FOLLOW instructions on display; Remark:3167
Procedure Step
Published
07/19/2021 2:55 PM
3169 - Note : Note: Optimal identification measurements are obtained when ...
Annotation
Published
07/19/2021 3:01 PM
3168 - FOLLOW instructions on display
Instruction
Published
07/19/2021 2:33 PM
3167 - IdentiFINDER2-NG Point unit to Source
Remark
Published
05/19/2022 5:52 PM
3172 - 2220 - Wait for measurement to complete; Remark:
Procedure Step
Published
04/20/2025 12:59 PM
2220 - Wait for measurement to complete
Instruction
Published
10/22/2020 11:15 AM
3202 - 927 - EVALUATE identification results; Remark:3201
Procedure Step
Published
07/19/2021 2:57 PM
927 - EVALUATE identification results
Instruction
Published
10/07/2022 12:52 PM
3201 - IDF2 - List of Identified Nuclides
Remark
Published
05/05/2021 2:20 PM
3204 - 3203 - REPEAT identification if necessary; Remark:
Procedure Step
Published
07/19/2021 2:58 PM
3203 - REPEAT identification if necessary
Instruction
Published
07/19/2021 2:30 PM
3207 - 3206 - NOTE name of saved spectrum; Remark:3205
Procedure Step
Published
07/19/2021 2:58 PM
3206 - NOTE name of saved spectrum
Instruction
Published
10/07/2022 12:53 PM
3205 - IDF2 - Name of Saved Spectrum
Remark
Published
05/05/2021 2:32 PM
3210 - 3209 - PRESS R to EXIT; Remark:3208
Procedure Step
Published
07/19/2021 2:59 PM
3209 - PRESS R to EXIT
Instruction
Published
10/07/2022 12:54 PM
3208 - IDF2_R_button_for_Exit
Remark
Published
05/06/2021 8:53 AM
3212 - 3211 - DOCUMENT and REPORT identification results; Remark:
Procedure Step
Published
07/19/2021 2:59 PM
3211 - DOCUMENT and REPORT identification results
Instruction
Published
07/19/2021 2:28 PM
3215 - 313 - Power off instrument; Remark:3213
Procedure Step
Published
04/07/2025 5:17 PM
313 - Power off instrument
Instruction
Published
07/23/2021 2:41 PM
3213 - PRESS M to confirm
Remark
Published
05/06/2021 9:04 AM
3218 - 3217 - CONNECT instrument to external power; Remark:3216
Procedure Step
Published
07/19/2021 2:59 PM
3217 - CONNECT instrument to external power
Instruction
Published
07/19/2021 2:26 PM
3216 - IDF2_Connect_to_Power
Remark
Published
05/06/2021 9:23 AM
3225 - Reminder : The identiFINDER charger and the internal charging port can be damaged if the...
Annotation
Published
07/19/2021 2:23 PM
3226 - Reminder : Always use the safety strap to minimize potential damage to the instrument.
Annotation
Published
07/19/2021 2:24 PM
3227 - Reminder : Do not expose instrument to a sudden change in temperature of more than 30°C...
Annotation
Published
07/19/2021 2:25 PM
Pocket Guide
Document Type
Published
03/02/2020 3:32 PM
Note
Annotation Type
Published
03/02/2020 3:25 PM
Reminder
Annotation Type
Published
04/08/2020 12:21 PM
IDF Remove Cable to Charger
Imagine
Published
05/01/2021 2:01 AM
No Radiation Symbol
Imagine
Published
08/13/2024 2:56 PM
IDF Power Button on Face of Device
Imagine
Published
05/01/2021 2:01 AM
IDF Battery Charge Level Icon Corner Screen
Imagine
Published
05/01/2021 2:01 AM
IDF Left Button
Imagine
Published
05/01/2021 2:01 AM
IDF Scan Raster Truck Side
Imagine
Published
05/01/2021 2:01 AM
IDF Finder Mode Rolling Graph Peaks
Imagine
Published
05/01/2021 2:01 AM
IDF Locate Source with Cross Pattern
Imagine
Published
05/01/2021 2:01 AM
Mark_Source_Location_Trefoil
Imagine
Published
02/19/2023 10:54 AM
IdentiFINDER2-NG M for IDENT
Imagine
Published
05/04/2021 1:59 AM
identiFINDER Keep Distance RedArrow
Imagine
Published
05/19/2022 5:46 PM
IDF Isotope List
Imagine
Published
05/01/2021 2:01 AM
IDF Isotope SMALL Event Record Number
Imagine
Published
05/01/2021 2:01 AM
IDF2_R_button_to_exit
Imagine
Published
05/06/2021 2:00 AM
IDF2_Shut_Down
Imagine
Published
05/08/2021 2:11 AM
IDF Reconnect Cable to Charge Battery
Imagine
Published
05/01/2021 2:01 AM
DET-HHD-FLR-IDF-PG01

Search for and identify radioactive material

Equipment Hierarchy
FLIR identiFINDER 2 NG
Technician Level
Duration
Identification
Step 16
Step 18
Main Step
Step 25
Main Step
Reminders
Document Type
Pocket Guide
Percent Complete
100.00
Percent Complete W/Media
100.00