Norma https://d5.pnnl.gov/mt mt 2884 - Standard : High voltage for a GE Reuter-Stokes neutron detection is 990 Volts. High volt... https://d5.pnnl.gov/en/annotation/2884-standard-high-voltage-ge-reuter-stokes-neutron-detection-990-volts-high-volt <span class="field field--name-title field--type-string field--label-hidden">2884-Norma : Vysoké napätie pre neutrónový detektor GE Reuter-Stokes je 990 voltov. Vysoké na...</span> <span class="field field--name-uid field--type-entity-reference field--label-hidden"><span lang="" about="/mt/user/21" typeof="schema:Person" property="schema:name" datatype="">jSmall</span></span> <span class="field field--name-created field--type-created field--label-hidden">Wed, 03/24/2021 - 20:01</span> <div class="field field--name-field-type field--type-entity-reference field--label-inline clearfix"> <div class="field__label">Type</div> <div class="field__item">Norma</div> </div> <div class="clearfix text-formatted field field--name-field-description field--type-text-long field--label-hidden field__item"><p>Vysoké napätie pre neutrónový detektor GE Reuter-Stokes je 990 voltov. Vysoké napätie pre neutrónový detektor LND je 1075 voltov.</p></div> Thu, 25 Mar 2021 03:01:37 +0000 jSmall 2884 at https://d5.pnnl.gov 2641 - Standard : 2nd stage gain = Peak location should be at channel 310 +/- 5 channels. https://d5.pnnl.gov/en/annotation/2641-standard-2nd-stage-gain-peak-location-should-be-channel-310-5-channels <span class="field field--name-title field--type-string field--label-hidden">2641-Norma : 2. intenzita = umiestnenie píku by malo byť na kanáli 310 +/- 5 kanálov.</span> <span class="field field--name-uid field--type-entity-reference field--label-hidden"><span lang="" about="/mt/user/20" typeof="schema:Person" property="schema:name" datatype="">jDorian</span></span> <span class="field field--name-created field--type-created field--label-hidden">Fri, 03/19/2021 - 18:19</span> <div class="field field--name-field-type field--type-entity-reference field--label-inline clearfix"> <div class="field__label">Type</div> <div class="field__item">Norma</div> </div> <div class="clearfix text-formatted field field--name-field-description field--type-text-long field--label-hidden field__item"><p>2. intenzita = umiestnenie píku by malo byť na kanáli 310 +/- 5 kanálov.</p></div> Sat, 20 Mar 2021 01:19:29 +0000 jDorian 2641 at https://d5.pnnl.gov 2640 - Standard : 1st stage gain = Peak location should be at channel 115 +/- 3 channels. https://d5.pnnl.gov/en/annotation/2640-standard-1st-stage-gain-peak-location-should-be-channel-115-3-channels <span class="field field--name-title field--type-string field--label-hidden">2640-Norma : 1. intenzita = umiestnenie píku by malo byť na kanáli 115 +/- 3 kanále.</span> <span class="field field--name-uid field--type-entity-reference field--label-hidden"><span lang="" about="/mt/user/20" typeof="schema:Person" property="schema:name" datatype="">jDorian</span></span> <span class="field field--name-created field--type-created field--label-hidden">Fri, 03/19/2021 - 18:18</span> <div class="field field--name-field-type field--type-entity-reference field--label-inline clearfix"> <div class="field__label">Type</div> <div class="field__item">Norma</div> </div> <div class="clearfix text-formatted field field--name-field-description field--type-text-long field--label-hidden field__item"><p>1. intenzita = umiestnenie píku by malo byť na kanáli 115 +/- 3 kanále.</p></div> Sat, 20 Mar 2021 01:18:03 +0000 jDorian 2640 at https://d5.pnnl.gov 2639 - Standard : Typical values are between 650 and 850 Volts DC. Older units might have highe... https://d5.pnnl.gov/en/annotation/2639-standard-typical-values-are-between-650-and-850-volts-dc-older-units-might-have <span class="field field--name-title field--type-string field--label-hidden">2639-Norma : Typické hodnoty sú medzi 650 a 850 voltov DC. Staršie zariadenia môžu mať vyššie...</span> <span class="field field--name-uid field--type-entity-reference field--label-hidden"><span lang="" about="/mt/user/20" typeof="schema:Person" property="schema:name" datatype="">jDorian</span></span> <span class="field field--name-created field--type-created field--label-hidden">Fri, 03/19/2021 - 18:16</span> <div class="field field--name-field-type field--type-entity-reference field--label-inline clearfix"> <div class="field__label">Type</div> <div class="field__item">Norma</div> </div> <div class="clearfix text-formatted field field--name-field-description field--type-text-long field--label-hidden field__item"><p>Typické hodnoty sú medzi 650 a 850 voltov DC. Staršie zariadenia môžu mať vyššie hodnoty napätia. Maximálne vysoké napätie gama by nemalo byť vyššie ako 1250 voltov..</p></div> Sat, 20 Mar 2021 01:16:47 +0000 jDorian 2639 at https://d5.pnnl.gov 2637 - Standard : Use the following file naming convention: CO_SITE_MO_SN_STG_PP CO =... https://d5.pnnl.gov/en/annotation/2637-standard-use-following-file-naming-convention-cositemosnstgpp-co <span class="field field--name-title field--type-string field--label-hidden">2637-Norma : Použite nasledovnú konvenciu pomenovania súboru: CO_SITE_MO_SN_STG_PPCO = NSDD š...</span> <span class="field field--name-uid field--type-entity-reference field--label-hidden"><span lang="" about="/mt/user/20" typeof="schema:Person" property="schema:name" datatype="">jDorian</span></span> <span class="field field--name-created field--type-created field--label-hidden">Fri, 03/19/2021 - 18:12</span> <div class="field field--name-field-type field--type-entity-reference field--label-inline clearfix"> <div class="field__label">Type</div> <div class="field__item">Norma</div> </div> <div class="clearfix text-formatted field field--name-field-description field--type-text-long field--label-hidden field__item"><p>Použite nasledovnú</p><p> konvenciu pomenovania súboru: CO_SITE_MO_SN_STG_PP</p><p>CO = NSDD štandardný kó krajiny</p><p>SITE = NSDD kód pracoviska</p><p>MO = PRM-470 číslo modelu (buď CG alebo CGN)</p><p>SN = PRM-470 sériové číslo</p><p>STG = intenzita (1. alebo 2.)</p><p>PP = meranie pred alebo po nastavení intenzity (PRED alebo PO)</p><p>Príklad: US_Richland_CG_1045_1ST_PRE</p></div> Sat, 20 Mar 2021 01:12:55 +0000 jDorian 2637 at https://d5.pnnl.gov 2635 - Standard : At least 2,000 counts should be recorded on the peak channel. https://d5.pnnl.gov/en/annotation/2635-standard-least-2000-counts-should-be-recorded-peak-channel <span class="field field--name-title field--type-string field--label-hidden">2635-Norma : Na kanáli píku (vrholu) by sa malo načítať najmenej 2 000 impulzov.</span> <span class="field field--name-uid field--type-entity-reference field--label-hidden"><span lang="" about="/mt/user/20" typeof="schema:Person" property="schema:name" datatype="">jDorian</span></span> <span class="field field--name-created field--type-created field--label-hidden">Fri, 03/19/2021 - 18:03</span> <div class="field field--name-field-type field--type-entity-reference field--label-inline clearfix"> <div class="field__label">Type</div> <div class="field__item">Norma</div> </div> <div class="clearfix text-formatted field field--name-field-description field--type-text-long field--label-hidden field__item"><p>Na kanáli píku (vrholu) by sa malo načítať najmenej 2 000 impulzov.</p></div> Sat, 20 Mar 2021 01:03:26 +0000 jDorian 2635 at https://d5.pnnl.gov