Last Updated: 06/18/2025 2:42 PM
The following table lists all the components that make up the document.
Replace a faulty BEA IXIO-DT1 occupancy sensor. This procedure can also be used to replace a faulty BEA Wizard G3 occupancy sensor.
Prior to arrival, notify operators concerning expected work, duration, and anticipated alarms and fault indications.
7264 - 1401 - Establish Initial Conditions; Remark:
1401 - Establish Initial Conditions
Establish Initial Conditions
7622 - 7592 - Inform system operators; Remark:11335
7592 - Inform system operators
Inform system operators
11335 - Upon arrival, brief system operators on expected work, duration, anticipated ...
Upon arrival, brief system operators on expected work, duration, anticipated alarms, and fault indications before starting work.
7452 - 7231 - Close lane; Remark:7415
7231 - Close lane
Close lane
7415 - Re-route pedestrian traffic.
Re-route pedestrian traffic.
7269 - 7232 - Open RPM door; Remark:7234
7232 - Open RPM door
Open RPM door
7234 - Open all doors needed to access components.
Open all doors needed to access components.
7270 - 7235 - Power off RPM; Remark:7236
7235 - Power off RPM
Power off RPM
7236 - Move LD-260 switch to OFF position. The PWR ON
Move LD-260 switch to OFF position. The PWR ON LED will turn off.

7755 - 7679 - Disconnect Ethernet; Remark:11336
7680 - Caution : Make sure to press release button on back of Ethernet cable before removing.
Make sure to press release button on back of Ethernet cable before removing.
7679 - Disconnect Ethernet
Disconnect Ethernet
11336 - Locate Ethernet connector on top of SC-770 controller. Press release button o...
Locate Ethernet connector on top of SC-770 controller. Press release button on back of connector. Pull connector.

7454 - 7290 - Disable tamper switches; Remark:7416
7290 - Disable tamper switches
Disable tamper switches
7416 - Use a magnet to disable tamper switches for all open doors. Use adhesive tape...
Use a magnet to disable tamper switches for all open doors. Use adhesive tape to disable older mechanical switches.


8561 - 7291 - Disable both infrared occupancy sensors; Remark:8514
5291 - Note : It is good practice to verify all cables and connectors are labeled prior to ...
It is good practice to verify all cables and connectors are labeled prior to disconnection.
7291 - Disable both infrared occupancy sensors
Disable both infrared occupancy sensors
8514 - Verify sensors mounted in control pillar door are receivers.
Verify sensors mounted in control pillar door are receivers.


9205 - To disconnect sensor cable, turn collar counterclockwise and pull away from s...
To disconnect sensor cable, turn collar counterclockwise and pull away from sensor.


7479 - 7417 - Prepare New Occupancy Sensor; Remark:
7417 - Prepare New Occupancy Sensor
Prepare New Occupancy Sensor
7456 - 7418 - Remove cover from new occupancy sensor; Remark:7419
7418 - Remove cover from new occupancy sensor
Remove cover from new occupancy sensor
7419 - Use a slotted screwdriver to pry the cover off from the side.
Use a slotted screwdriver to pry the cover off from the side.

7457 - 7420 - Verify narrow field radar antenna is installed; Remark:7421
7420 - Verify narrow field radar antenna is installed
Verify narrow field radar antenna is installed
7421 - The IXIO-DT1 should come with the narrow field antenna installed.
The IXIO-DT1 should come with the narrow field antenna installed.

8901 - If needed, the antenna can be changed. Remove cover. Install narrow field ant...
If needed, the antenna can be changed. Remove cover. Install narrow field antenna stored in slot behind antenna mount. Replace cover.


7480 - 7422 - Uninstall Faulty Occupancy Sensor; Remark:
7422 - Uninstall Faulty Occupancy Sensor
Uninstall Faulty Occupancy Sensor
7458 - 7423 - Remove Cover; Remark:7424
7423 - Remove Cover
Remove Cover
7424 - If needed, use a sharp utility knife to cut sealant around edges of sensor. A...
If needed, use a sharp utility knife to cut sealant around edges of sensor. A slotted screwdriver is needed to remove the cover.

7459 - 7425 - Disconnect wire connector; Remark:7426
7425 - Disconnect wire connector
Disconnect wire connector
7426 - The wire connector is located on the right side of existing sensor.
The wire connector is located on the right side of existing sensor.

7460 - 7427 - Loosen two (2) mounting screws; Remark:7428
7429 - Note : Some existing occupancy sensors are installed using screws and nuts, ...
- Some existing occupancy sensors are installed using screws and nuts, others are installed using self tapping screws.
- Removal and replacement only requires mounting screws to be loose, not completely removed.
7427 - Loosen two (2) mounting screws
Loosen two (2) mounting screws
7428 - Use a medium Phillips (PH2) screwdriver. If screws and nuts were used, an adj...
Use a medium Phillips (PH2) screwdriver. If screws and nuts were used, an adjustable wrench may be needed.

7461 - 7430 - Remove faulty occupancy sensor; Remark:7431
7430 - Remove faulty occupancy sensor
Remove faulty occupancy sensor
7431 - If a Wizard G3 sensor is being removed, push up on both sides to free the sen...
If a Wizard G3 sensor is being removed, push up on both sides to free the sensor from the mounting screws. If an IXIO-DT1 sensor is being removed, push up on right side and slide sensor to the right.


3397 - 3395 - Označte vadnou součástku; Remark:3396
3395 - Označte vadnou součástku
Označte vadnou součástku
3396 - Použijte štítek nebo pásku. Uveďte datum odstranění, popis známek vady, zemi, mí...
Použijte štítek nebo pásku. Uveďte datum odstranění, popis známek vady, zemi, místo a číslo pruhu. Zlikvidujte v souladu s pokyny organizace NSDD (Nuclear Smuggling Detection and Deterrence) nebo smluvními požadavky.
7481 - 7432 - Install new occupancy sensor; Remark:
7432 - Install new occupancy sensor
Install new occupancy sensor
7463 - 7433 - Mount new sensor; Remark:7434
7433 - Mount new sensor
Mount new sensor
7434 - First, slide left side onto mounting screw.
First, slide left side onto mounting screw.

9206 - Then, place right side over mounting screw and push down.
Then, place right side over mounting screw and push down.

7464 - 7435 - Tighten two (2) mounting screws; Remark:7436
7435 - Tighten two (2) mounting screws
Tighten two (2) mounting screws
7436 - Use medium Phillips (PH2) screwdriver. Take care not to overtighten.
Use medium Phillips (PH2) screwdriver. Take care not to overtighten.

7482 - 7437 - Route wiring through clamp and connect; Remark:7488
7437 - Route wiring through clamp and connect
Route wiring through clamp and connect
7488 - Clamp and Connect

7465 - 7439 - Adjust angle of the radar antenna; Remark:7438
7439 - Adjust angle of the radar antenna
Adjust angle of the radar antenna
7438 - The angle is adjusted by manually rotating the antenna up or down. The defaul...
The angle is adjusted by manually rotating the antenna up or down. The default angle is approximately 15 degrees.


7279 - 7249 - Return equipment to normal operating condition; Remark:
7249 - Return equipment to normal operating condition
Return equipment to normal operating condition
7466 - 7440 - Hold door open; Remark:7441
7440 - Hold door open
Hold door open
7441 - Do not move door. Door must remain stationary to prevent occupancy.
Do not move door. Door must remain stationary to prevent occupancy.
7280 - 7250 - Power on RPM; Remark:7251
7250 - Power on RPM
Power on RPM
7251 - Move LD-260 switch to ON position. The LED PWR ON
Move LD-260 switch to ON position. The LED PWR ON will illuminate.

7281 - 7252 - Verify RPM start-up; Remark:7253
7252 - Verify RPM start-up
Verify RPM start-up
7253 - RPM will perform a power on self-test (POST) and collect a background radiati...
RPM will perform a power on self-test (POST) and collect a background radiation measurement.
8587 - 7305 - Enable both infrared occupancy sensors; Remark:8559
5553 - Caution : Correct placement of connectors and wiring is critical to proper operation.
Correct placement of connectors and wiring is critical to proper operation.
7305 - Enable both infrared occupancy sensors
Enable both infrared occupancy sensors
8559 - To reconnect sensor cable, align connectors, push towards sensor, and turn co...
To reconnect sensor cable, align connectors, push towards sensor, and turn collar clockwise.



7474 - 7310 - Enable tamper switches; Remark:7451
7310 - Enable tamper switches
Enable tamper switches
7451 - Remove magnets and/or adhesive tape from door tamper switches.
Remove magnets and/or adhesive tape from door tamper switches.

7781 - 7730 - Reconnect Ethernet; Remark:7731
7730 - Reconnect Ethernet
Reconnect Ethernet
7731 - Insert Ethernet connector at top of SC-770 module. Connector will audibly "cl...
Insert Ethernet connector at top of SC-770 module. Connector will audibly "click" when seated properly.
7282 - 7254 - Confirm network connection; Remark:7255
7254 - Confirm network connection
Confirm network connection
7255 - Contact operators to confirm communications have been reestablished between RPM ...
7470 - 7442 - Generate occupancy; Remark:7443
7442 - Generate occupancy
Generate occupancy
7443 - Create motion in front of occupancy sensor. While holding the door open and s...
Create motion in front of occupancy sensor. While holding the door open and still, wave a hand or walk in front of the sensor.
7471 - 7444 - Verify occupancy sensor functionality; Remark:7445
7444 - Verify occupancy sensor functionality
Verify occupancy sensor functionality
7445 - IXIO-DT1 green sensor light will illuminate.
IXIO-DT1 green sensor light will illuminate.

8973 - Left latch on the LCD screen will indicate a “closed” circuit.
Left latch on the LCD screen will indicate a “closed” circuit.

8974 - SC-770 status will read “OCCUPIED”.
SC-770 status will read “OCCUPIED”.

7472 - 7446 - Install sensor cover; Remark:7447
7446 - Install sensor cover
Install sensor cover
7447 - The cover should snap into place.
The cover should snap into place.

7473 - 7448 - If needed, apply sealant; Remark:7449
7448 - If needed, apply sealant
If needed, apply sealant
7449 - If used outdoors, sealant should be applied to top and sides of cover. Do not...
If used outdoors, sealant should be applied to top and sides of cover. Do not apply sealant along bottom of cover. Remove excess silicone with mineral spirits and rags.

9385 - 319 - Perform operational test; Remark:9347
319 - Perform operational test
Perform operational test
9347 - DET-RPM-RAP-RM03 RPM Operational Test.
DET-RPM-RAP-RM03 RPM Operational Test.
7283 - 7256 - Close and lock all RPM doors; Remark:
7256 - Close and lock all RPM doors
Close and lock all RPM doors
8260 - 8250 - Reopen Lane; Remark:8249
8250 - Reopen Lane
Reopen Lane
8249 - Remove orange safety (traffic control) cones
Remove orange safety (traffic control) cones
7842 - 7820 - Inform system operators upon completion of maintenance action; Remark:
7820 - Inform system operators upon completion of maintenance action
Inform system operators upon completion of maintenance action
322 - 321 - Zaznamenání úkonů údržby; Remark:
321 - Zaznamenání úkonů údržby
Zaznamenání úkonů údržby
2869 - 2585 - Zaznamenejte provedenou údržbu; Remark:2866
2585 - Zaznamenejte provedenou údržbu
Zaznamenejte provedenou údržbu
2866 - Zaznamenejte připomínky, časy a výsledky do zprávy o opravné údržbě.
Zaznamenejte připomínky, časy a výsledky do zprávy o opravné údržbě.
4706 - 4705 - Odešlete zprávu; Remark:4864
4705 - Odešlete zprávu
Odešlete zprávu
4864 - Dle pokynů vedení nebo smluvních závazků.