Sensor Tech Handheld Radiation Monitor |
Device
|
Published
|
10/28/2024 3:52 PM
|
247 - 257 - Prepare instrument; Remark: |
Procedure Step
|
Published
|
04/11/2025 9:08 PM
|
257 - Prepare instrument |
Instruction
|
Published
|
04/11/2025 9:07 PM
|
786 - 219 - Verify there are no sources of radiation near instrument; Remark:7 |
Procedure Step
|
Published
|
04/20/2025 6:37 PM
|
219 - Verify there are no sources of radiation near instrument |
Instruction
|
Published
|
04/12/2025 4:20 PM
|
7 - No Radiation symbol |
Remark
|
Published
|
07/12/2021 1:34 PM
|
4316 - 220 - Power on instrument; Remark:4315 |
Procedure Step
|
Published
|
06/06/2022 5:58 PM
|
220 - Power on instrument |
Instruction
|
Published
|
04/06/2025 7:00 PM
|
4315 - Set instrument to AUDIO mode. |
Remark
|
Published
|
06/06/2022 5:58 PM
|
4290 - 612 - Wait for instrument to complete start-up sequence; Remark:4286 |
Procedure Step
|
Published
|
04/13/2025 6:50 PM
|
612 - Wait for instrument to complete start-up sequence |
Instruction
|
Published
|
04/13/2025 6:38 PM
|
4286 - The unit is ready for operation when the period flashes every 20 seconds.... |
Remark
|
Published
|
06/06/2022 4:11 PM
|
252 - 232 - Check instrument gamma response; Remark: |
Procedure Step
|
Published
|
07/29/2021 11:10 AM
|
232 - Check instrument gamma response |
Instruction
|
Published
|
07/23/2021 9:58 AM
|
4312 - 235 - Place instrument next to radioactive gamma source; Remark:4884 |
Procedure Step
|
Published
|
06/06/2022 6:00 PM
|
235 - Place instrument next to radioactive gamma source |
Instruction
|
Published
|
07/09/2021 1:39 PM
|
4884 - IO HRM Move Closer to Rad Source |
Remark
|
Published
|
08/04/2022 1:44 PM
|
4313 - 2936 - Zkontrolujte, že zvukový alarm funguje správně; Remark:4310 |
Procedure Step
|
Published
|
06/06/2022 6:02 PM
|
2936 - Verify audible alarm functions correctly |
Instruction
|
Published
|
06/15/2021 4:09 PM
|
4310 - The instrument should respond as follows: Instrument will e... |
Remark
|
Published
|
06/06/2022 6:01 PM
|
4311 - Numeric value will appear in the gamma LED [light-emitting diode] dis... |
Remark
|
Published
|
06/06/2022 6:02 PM
|
4314 - 241 - Vzdalte přístroj od radioaktivního zdroje gama záření; Remark:4883 |
Procedure Step
|
Published
|
06/06/2022 6:03 PM
|
241 - Move instrument away from radioactive gamma source |
Instruction
|
Published
|
06/25/2021 12:22 PM
|
4883 - IO HRM Move Away from Rad Source |
Remark
|
Published
|
08/04/2022 1:47 PM
|
2914 - 2912 - Test vibration alarm; Remark: |
Procedure Step
|
Published
|
06/06/2022 5:28 PM
|
2912 - Test vibration alarm |
Instruction
|
Published
|
06/15/2021 4:11 PM
|
4320 - 4319 - Change to VIBRATE mode; Remark:4318 |
Procedure Step
|
Published
|
06/06/2022 6:08 PM
|
4319 - Change to VIBRATE mode |
Instruction
|
Published
|
06/06/2022 6:07 PM
|
4318 - Quickly move switch to VIBRATE. |
Remark
|
Published
|
06/06/2022 6:08 PM
|
4323 - 2938 - Zkontrolujte, že vibrační alarm funguje správně; Remark:4321 |
Procedure Step
|
Published
|
06/06/2022 6:12 PM
|
2938 - Verify vibration alarm functions correctly |
Instruction
|
Published
|
06/15/2021 4:12 PM
|
4321 - The instrument should respond as follows: Instrument will v... |
Remark
|
Published
|
06/06/2022 6:11 PM
|
4322 - Numeric value will appear in the gamma LED display. |
Remark
|
Published
|
06/06/2022 6:11 PM
|
4329 - 4328 - Check response with neutron radioactive source; Remark: |
Procedure Step
|
Published
|
06/06/2022 6:21 PM
|
4332 - Note : The neutron response can be performed using a neutron radioactive source or b... |
Annotation
|
Published
|
06/06/2022 6:37 PM
|
4328 - Check response with neutron radioactive source |
Instruction
|
Published
|
06/06/2022 6:21 PM
|
4326 - 3095 - Umístěte přístroj vedle zdroje radioaktivního neutronového záření; Remark:4884 |
Procedure Step
|
Published
|
06/06/2022 6:31 PM
|
3095 - Place instrument next to radioactive neutron source |
Instruction
|
Published
|
07/16/2021 10:49 AM
|
4325 - 3097 - Zkontrolujte, že přístroj reaguje správně; Remark:4310 |
Procedure Step
|
Published
|
06/06/2022 6:24 PM
|
3096 - Note : Most radioactive neutron sources also have a gamma component, which will likely ... |
Annotation
|
Published
|
07/23/2021 9:57 AM
|
3097 - Verify instrument responds correctly |
Instruction
|
Published
|
07/16/2021 10:50 AM
|
4324 - Numeric value will appear in the neutron LED display. Blue... |
Remark
|
Published
|
06/06/2022 6:24 PM
|
4327 - 3098 - Vzdalte přístroj od zdroje radioaktivního neutronového záření; Remark:4883 |
Procedure Step
|
Published
|
06/06/2022 6:32 PM
|
3098 - Move instrument away from radioactive neutron source |
Instruction
|
Published
|
07/16/2021 10:54 AM
|
4338 - 3095 - Umístěte přístroj vedle zdroje radioaktivního neutronového záření; Remark:4884 |
Procedure Step
|
Published
|
06/06/2022 6:31 PM
|
4331 - 3097 - Zkontrolujte, že přístroj reaguje správně; Remark:4321 |
Procedure Step
|
Published
|
06/06/2022 6:51 PM
|
4330 - Numeric value will appear in the neutron LED display. Blue... |
Remark
|
Published
|
06/06/2022 6:51 PM
|
4339 - 3098 - Vzdalte přístroj od zdroje radioaktivního neutronového záření; Remark:4883 |
Procedure Step
|
Published
|
06/06/2022 6:32 PM
|
4337 - 4335 - Check response with background neutron radiation; Remark: |
Procedure Step
|
Published
|
06/06/2022 7:01 PM
|
4336 - Note : If no neutron radioactive source is available, the following step can be used... |
Annotation
|
Published
|
06/06/2022 7:01 PM
|
4335 - Check response with background neutron radiation |
Instruction
|
Published
|
06/06/2022 7:01 PM
|
4344 - 4343 - Sledujte kontrolku neutronového záření; Remark:4342 |
Procedure Step
|
Published
|
06/06/2022 7:11 PM
|
4343 - Monitor neutron LED |
Instruction
|
Published
|
06/06/2022 7:10 PM
|
4342 - Watch neutron LED carefully in a low-light environment for at least 5 minutes... |
Remark
|
Published
|
06/06/2022 7:11 PM
|
4345 - 4341 - Zkontrolujte, že přístroj reaguje na neutronové záření na pozadí; Remark:4340 |
Procedure Step
|
Published
|
06/06/2022 7:13 PM
|
4341 - Verify instrument responds to background neutron radiation |
Instruction
|
Published
|
06/06/2022 7:11 PM
|
4340 - In natural background, the instrument should respond about one (1) to three (... |
Remark
|
Published
|
06/06/2022 7:13 PM
|
4349 - 4343 - Sledujte kontrolku neutronového záření; Remark:4342 |
Procedure Step
|
Published
|
06/06/2022 7:11 PM
|
4350 - 4341 - Zkontrolujte, že přístroj reaguje na neutronové záření na pozadí; Remark:4348 |
Procedure Step
|
Published
|
06/06/2022 7:17 PM
|
4348 - In natural background, the instrument should respond about one (1) to three (... |
Remark
|
Published
|
06/06/2022 7:16 PM
|
253 - 242 - Document and report any unresolved problems; Remark: |
Procedure Step
|
Published
|
06/22/2021 10:23 AM
|
242 - Document and report any unresolved problems |
Instruction
|
Published
|
04/21/2025 11:45 AM
|
Routine Maintenance Procedure |
Document Type
|
Published
|
03/02/2020 3:31 PM
|
minutes |
Duration
|
Published
|
05/26/2022 11:41 AM
|
Before each use |
Frequency
|
Published
|
08/31/2020 5:00 PM
|
Daily |
Frequency
|
Published
|
04/01/2020 11:36 AM
|
Note |
Annotation Type
|
Published
|
03/02/2020 3:25 PM
|
Technician 1 |
Skill Level
|
Published
|
05/14/2020 2:56 PM
|
None |
Tools
|
Published
|
05/06/2020 9:50 PM
|
No Radiation Symbol |
Image
|
Published
|
08/13/2024 2:56 PM
|
HRM Switch in AUDIO position |
Image
|
Published
|
08/02/2022 5:03 PM
|
HRM Red LED Dot Period |
Image
|
Published
|
08/02/2022 4:53 PM
|
HRM Move to Rad Source Trefoil |
Image
|
Published
|
08/02/2022 7:57 PM
|
HRM Alert Audio |
Image
|
Published
|
08/02/2022 7:51 PM
|
HRM Red LED Display 3 |
Image
|
Published
|
08/02/2022 7:47 PM
|
HRM Move away from Rad Source Trefoil |
Image
|
Published
|
08/02/2022 7:59 PM
|
HRM Switch in VIBRATE position |
Image
|
Published
|
08/02/2022 5:06 PM
|
HRM Alert Vibrate |
Image
|
Published
|
08/02/2022 7:52 PM
|
HRM Alert Audio Neutron Full Size |
Image
|
Published
|
08/04/2022 4:58 PM
|
HRM Alert Blue LED Neutron Level 3 |
Image
|
Published
|
08/03/2022 10:29 AM
|
HRM Alert Vibrate Neutron Full Size |
Image
|
Published
|
08/04/2022 5:00 PM
|
HRM Alert Audio Neutron |
Image
|
Published
|
08/03/2022 10:32 AM
|
HRM Alert Vibrate Neutron |
Image
|
Published
|
08/03/2022 10:34 AM
|