Abbreviation
OP

VeriFinder Operation

Last Updated: 07/15/2025 1:36 AM

The following table lists all the components that make up the document.

Title Type Status Last Updated
Symetrica VeriFinder SN-20
Device
Published
07/09/2025 4:17 PM
247 - 257 - Prepare instrument; Remark:
Procedure Step
Published
04/11/2025 9:08 PM
257 - Prepare instrument
Instruction
Published
04/11/2025 9:07 PM
786 - 219 - Verify there are no sources of radiation near instrument; Remark:7
Procedure Step
Published
04/20/2025 6:37 PM
219 - Verify there are no sources of radiation near instrument
Instruction
Published
04/12/2025 4:20 PM
7 - No Radiation symbol
Remark
Published
07/12/2021 1:34 PM
2426 - 2391 - Press and hold POWER/SELECT button for 3 seconds; Remark:652
Procedure Step
Published
04/06/2021 6:43 PM
2391 - Press and hold POWER/SELECT button for 3 seconds
Instruction
Published
04/06/2021 4:36 PM
652 - IO VeriFinder POWER/SELECT Button
Remark
Published
11/11/2024 7:17 AM
2427 - 612 - Wait for instrument to complete start-up sequence; Remark:2393
Procedure Step
Published
04/13/2025 6:48 PM
2418 - Note : You can press the POWER/SELECT button at any time during the start-up sequenc...
Annotation
Published
04/06/2021 6:49 PM
612 - Wait for instrument to complete start-up sequence
Instruction
Published
04/13/2025 6:38 PM
2393 - IO VeriFinder Display Stabilizing
Remark
Published
11/11/2024 4:13 PM
2428 - 2390 - Press POWER/SELECT button to acknowledge “New Background Needed” message,...; Remark:2392
Procedure Step
Published
04/06/2021 6:49 PM
2390 - Press POWER/SELECT button to acknowledge “New Background Needed” message,...
Instruction
Published
04/06/2021 4:42 PM
2392 - The instrument will display a reminder during the start-up sequence if it has...
Remark
Published
04/06/2021 6:33 PM
2429 - 2295 - Verify sufficient battery charge; Remark:651
Procedure Step
Published
04/06/2021 6:50 PM
2419 - Note : The VeriFinder comes with an adaptor to install standard AA batteries to oper...
Annotation
Published
04/06/2021 6:52 PM
2295 - Verify sufficient battery charge
Instruction
Published
04/06/2021 4:43 PM
651 - IO VeriFinder Battery Status Display
Remark
Published
11/11/2024 7:19 AM
2430 - 2206 - Connect headphones (optional); Remark:2394
Procedure Step
Published
04/06/2021 6:52 PM
2206 - Connect headphones (optional)
Instruction
Published
04/06/2021 4:45 PM
2394 - IO VeriFinder Headphone Connection Port
Remark
Published
11/11/2024 4:13 PM
10828 - 3494 - Collect background measurement; Remark:
Procedure Step
Published
07/21/2024 3:38 PM
3494 - Collect background measurement
Instruction
Published
08/27/2024 5:25 PM
2432 - 2209 - Verify instrument is in a suitable background radiation area; Remark:2395
Procedure Step
Published
04/06/2021 6:53 PM
2209 - Verify instrument is in a suitable background radiation area
Instruction
Published
06/11/2024 3:31 PM
2395 - The instrument should be located near the secondary inspection area, in simil...
Remark
Published
04/06/2021 6:34 PM
2433 - 2389 - Press BACK button to open the menu bar; Remark:2396
Procedure Step
Published
04/06/2021 6:53 PM
2389 - Press BACK button to open the menu bar
Instruction
Published
04/06/2021 4:48 PM
2396 - IO VeriFinder Display Menu on Bar
Remark
Published
11/11/2024 3:31 PM
653 - IO VeriFinder BACK Button on Left
Remark
Published
11/11/2024 7:21 AM
2434 - 2388 - Press DOWN button to scroll to user settings icon; Remark:2397
Procedure Step
Published
04/06/2021 6:54 PM
2388 - Press DOWN button to scroll to user settings icon
Instruction
Published
04/06/2021 4:49 PM
2397 - IO VeriFinder Display Gear Icon for Settings
Remark
Published
11/11/2024 4:14 PM
2398 - IO VeriFinder DOWN Button on Right
Remark
Published
11/11/2024 4:16 PM
2435 - 2387 - Press POWER/SELECT button to select user settings; Remark:
Procedure Step
Published
04/06/2021 6:54 PM
2387 - Press POWER/SELECT button to select user settings
Instruction
Published
04/06/2021 4:51 PM
2436 - 2386 - Press POWER/SELECT button to select Background; Remark:2399
Procedure Step
Published
04/06/2021 6:54 PM
2386 - Press POWER/SELECT button to select Background
Instruction
Published
04/06/2021 4:52 PM
2399 - IO VeriFinder Display Background Option in Menu
Remark
Published
11/11/2024 4:16 PM
2437 - 2385 - Press POWER/SELECT button to start background collection; Remark:2400
Procedure Step
Published
04/06/2021 6:55 PM
2385 - Press POWER/SELECT button to start background collection
Instruction
Published
04/06/2021 4:54 PM
2400 - IO VeriFinder Display Collect New on Bar
Remark
Published
11/11/2024 4:18 PM
2438 - 2220 - Wait for measurement to complete; Remark:2401
Procedure Step
Published
04/20/2025 12:58 PM
2220 - Wait for measurement to complete
Instruction
Published
10/22/2020 11:15 AM
2401 - The blue bar on the left shows the time remaining.
Remark
Published
04/06/2021 6:39 PM
2439 - 2384 - Press DOWN button to view analysis; Remark:2402
Procedure Step
Published
04/06/2021 6:56 PM
2384 - Press DOWN button to view analysis
Instruction
Published
04/06/2021 4:58 PM
2402 - IO VeriFinder Display Analysis on Bar
Remark
Published
11/11/2024 4:17 PM
2440 - 2383 - Press BACK button after viewing analysis; Remark:2403
Procedure Step
Published
04/06/2021 6:57 PM
2383 - Press BACK button after viewing analysis
Instruction
Published
04/06/2021 5:01 PM
2403 - This analysis only shows naturally occurring isotopes and can be accepted.
Remark
Published
04/06/2021 6:05 PM
2404 - This analysis shows an industrial isotope and should be rejected.
Remark
Published
04/06/2021 6:59 PM
2441 - 2382 - Press POWER/SELECT button to accept background or press BACK button to reject...; Remark:2405
Procedure Step
Published
04/06/2021 7:00 PM
2420 - Note : If the background is rejected, move away from the source of radiation and col...
Annotation
Published
04/06/2021 7:01 PM
2382 - Press POWER/SELECT button to accept background or press BACK button to reject...
Instruction
Published
04/06/2021 5:03 PM
2405 - IO VeriFinder Display Accept on Bar
Remark
Published
11/11/2024 4:22 PM
2252 - 2213 - Search for Radioactive Material; Remark:
Procedure Step
Published
04/06/2021 7:01 PM
2213 - Search for Radioactive Material
Instruction
Published
04/06/2021 5:04 PM
2442 - 2381 - Enable audible indicator by pressing and holding BACK button until clicking s...; Remark:653
Procedure Step
Published
04/06/2021 7:02 PM
2381 - Enable audible indicator by pressing and holding BACK button until clicking s...
Instruction
Published
04/06/2021 5:06 PM
2443 - 2215 - Survey slowly over entire item; Remark:2406
Procedure Step
Published
04/06/2021 7:02 PM
2215 - Survey slowly over entire item
Instruction
Published
04/06/2021 5:07 PM
2406 - Keep the instrument close to the conveyance, object, or person being assessed...
Remark
Published
04/06/2021 6:10 PM
654 - IO VeriFinder Scanning Cargo in Raster Action
Remark
Published
11/11/2024 7:24 AM
2444 - 2380 - Observe display and listen to audible indicator (if enabled); Remark:655
Procedure Step
Published
04/06/2021 7:03 PM
2380 - Observe display and listen to audible indicator (if enabled)
Instruction
Published
04/06/2021 5:08 PM
655 - IO VeriFinder Display while Search No Alarm Background
Remark
Published
11/11/2024 7:24 AM
2445 - 2379 - Acknowledge instrument alarm by pressing POWER/SELECT button (as needed and o...; Remark:2407
Procedure Step
Published
04/06/2021 7:03 PM
2379 - Acknowledge instrument alarm by pressing POWER/SELECT button (as needed and o...
Instruction
Published
04/06/2021 5:09 PM
2407 - Acknowledging the alarm will stop the sound and vibration.
Remark
Published
04/06/2021 6:14 PM
656 - IO VeriFinder Alarm Acknowledge Gamma Alarm
Remark
Published
11/11/2024 7:25 AM
405 - 368 - Mark point(s) of interest; Remark:4277
Procedure Step
Published
04/20/2025 5:44 PM
368 - Mark point(s) of interest
Instruction
Published
06/11/2021 9:23 AM
4277 - Place a marker (tape, pencil, etc.) on points exhibiting elevated radiation. ...
Remark
Published
04/20/2025 5:37 PM
2251 - 2217 - Perform Identification Measurement; Remark:
Procedure Step
Published
07/28/2021 9:55 PM
2217 - Perform Identification Measurement
Instruction
Published
04/06/2021 5:13 PM
2446 - 2218 - Place instrument close to measurement location; Remark:
Procedure Step
Published
04/06/2021 7:05 PM
2218 - Place instrument close to measurement location
Instruction
Published
04/06/2021 5:15 PM
2447 - 2378 - Press POWER/SELECT button to start identification; Remark:657
Procedure Step
Published
04/06/2021 7:05 PM
2378 - Press POWER/SELECT button to start identification
Instruction
Published
04/06/2021 5:17 PM
657 - IO VeriFinder Start Identify Menu
Remark
Published
11/11/2024 7:26 AM
2448 - 2220 - Wait for measurement to complete; Remark:2408
Procedure Step
Published
04/20/2025 12:53 PM
2421 - Note : To add additional time to the identification measurement, press the DOWN butt...
Annotation
Published
04/06/2021 7:07 PM
2408 - The blue bar on the left shows the time remaining.
Remark
Published
04/06/2021 6:16 PM
658 - IO VeriFinder Display Timer Progress
Remark
Published
11/11/2024 7:38 AM
2449 - 2377 - Press POWER/SELECT to acknowledge alarm, if necessary; Remark:2409
Procedure Step
Published
06/10/2024 12:38 PM
2377 - Press POWER/SELECT to acknowledge alarm, if necessary
Instruction
Published
04/06/2021 5:19 PM
2409 - If an identification is made, the VeriFinder generates an alarm (threat or in...
Remark
Published
04/06/2021 6:18 PM
10638 - VeriFinder Acknowledge Alarm Choice
Remark
Published
11/11/2024 4:25 PM
2450 - 2221 - Observe identification results; Remark:659
Procedure Step
Published
04/06/2021 7:08 PM
2221 - Observe identification results
Instruction
Published
04/06/2021 5:20 PM
659 - IO VeriFinder Identification Complete Am-241
Remark
Published
11/11/2024 7:41 AM
2451 - 2376 - Press POWER/SELECT button to see a list of actions; Remark:664
Procedure Step
Published
04/06/2021 7:08 PM
2376 - Press POWER/SELECT button to see a list of actions
Instruction
Published
04/06/2021 5:21 PM
664 - IO VeriFinder Display Select Finish Action
Remark
Published
11/11/2024 7:47 AM
2410 - Finish will return to th...
Remark
Published
04/06/2021 7:12 PM
2367 - 2365 - Offload Spectra Onto Computer; Remark:
Procedure Step
Published
04/06/2021 7:13 PM
2365 - Offload Spectra Onto Computer
Instruction
Published
04/06/2021 5:22 PM
2452 - 2375 - Connect USB flash memory drive to instrument using accessory cable; Remark:2411
Procedure Step
Published
04/06/2021 7:14 PM
2375 - Connect USB flash memory drive to instrument using accessory cable
Instruction
Published
04/06/2021 5:22 PM
2411 - IO VeriFinder USB Connect Memory Drive
Remark
Published
11/11/2024 4:26 PM
2453 - 2374 - Press DOWN button to highlight Save to USB Drive and press P...; Remark:2412
Procedure Step
Published
04/06/2021 7:14 PM
2374 - Press DOWN button to highlight Save to USB Drive and press P...
Instruction
Published
04/06/2021 5:24 PM
2412 - IO VeriFinder Display Save to USB Drive Option
Remark
Published
11/11/2024 3:12 PM
2454 - 2373 - Wait for files to save; Remark:2413
Procedure Step
Published
04/06/2021 7:15 PM
2422 - Note : This will only save the spectrum from the most recent identification measurem...
Annotation
Published
04/06/2021 7:16 PM
2373 - Wait for files to save
Instruction
Published
04/06/2021 5:25 PM
2413 - When files are saved, the screen will briefly display “Export complete.” ...
Remark
Published
04/06/2021 6:22 PM
2455 - 2424 - Press POWER/SELECT button to Finish and return to Locate scr...; Remark:2414
Procedure Step
Published
04/06/2021 7:17 PM
2424 - Press POWER/SELECT button to Finish and return to Locate scr...
Instruction
Published
04/06/2021 5:27 PM
2414 - IO VeriFinder Display Finish Action Red Box
Remark
Published
11/11/2024 4:26 PM
2456 - 2372 - Remove USB flash drive from VeriFinder and connect to computer to obtain spec...; Remark:2415
Procedure Step
Published
04/06/2021 7:17 PM
2372 - Remove USB flash drive from VeriFinder and connect to computer to obtain spec...
Instruction
Published
04/06/2021 5:28 PM
2415 - The file can then be attached to the corresponding event in the central alarm...
Remark
Published
04/06/2021 6:25 PM
2366 - 2364 - Shut Down Instrument; Remark:
Procedure Step
Published
04/06/2021 7:18 PM
2364 - Shut Down Instrument
Instruction
Published
04/06/2021 5:29 PM
2457 - 2371 - Press and hold POWER/SELECT button for 5 seconds; Remark:652
Procedure Step
Published
04/06/2021 7:18 PM
2371 - Press and hold POWER/SELECT button for 5 seconds
Instruction
Published
04/06/2021 5:29 PM
2458 - 2370 - Connect to charger; Remark:2416
Procedure Step
Published
04/06/2021 7:18 PM
2423 - Note : The VeriFinder also comes with an external battery charger. This may be used ...
Annotation
Published
04/06/2021 7:20 PM
2370 - Connect to charger
Instruction
Published
04/06/2021 5:31 PM
2416 - The battery requires about 2.5 hours to fully recharge.
Remark
Published
04/06/2021 6:27 PM
660 - IO VeriFinder Battery Cable Connection Port
Remark
Published
11/11/2024 7:46 AM
2417 - Optional external battery charger
Remark
Published
04/06/2021 7:27 PM
Operator Procedure
Document Type
Published
03/02/2020 3:31 PM
Note
Annotation Type
Published
03/02/2020 3:25 PM
USB Memory Stick (recommended)
Tools
Published
09/10/2020 8:52 PM
USB accessory cable
Tools
Published
11/03/2020 12:14 PM
No Radiation Symbol
រូប​ភាព
Published
08/13/2024 2:56 PM
VeriFinder POWER/SELECT button
រូប​ភាព
Published
02/19/2023 3:51 PM
VeriFinder Start up Stabilizing Screen
រូប​ភាព
Published
10/29/2020 8:25 PM
VeriFinder Background Update Advice
រូប​ភាព
Published
10/29/2020 8:27 PM
VeriFinder Display of Battery Status
រូប​ភាព
Published
05/15/2020 2:48 PM
VeriFinder Headphone Connection
រូប​ភាព
Published
10/29/2020 4:03 PM
VeriFinder Open Menu
រូប​ភាព
Published
10/29/2020 8:18 PM
Verifinder BACK Button Left
រូប​ភាព
Published
02/19/2023 3:53 PM
Verifinder Settings Icon Gear
រូប​ភាព
Published
10/29/2020 8:22 PM
Verifinder DOWN Button Right
រូប​ភាព
Published
10/29/2020 3:59 PM
VeriFinder Background Setting Menu
រូប​ភាព
Published
10/29/2020 4:42 PM
VeriFinder Collect New Background
រូប​ភាព
Published
10/29/2020 4:49 PM
VeriFinder Wait Time for Background
រូប​ភាព
Published
10/29/2020 8:29 PM
VeriFinder Analysis Choice
រូប​ភាព
Published
10/29/2020 4:28 PM
VeriFinder Back Acknowledge NORM in Background
រូប​ភាព
Published
10/29/2020 4:38 PM
VeriFinder Back Acknowledge Industrial in Background
រូប​ភាព
Published
10/29/2020 4:34 PM
VeriFinder Accept Choice
រូប​ភាព
Published
10/29/2020 4:21 PM
VeriFinder Scan Cargo Container Raster
រូប​ភាព
Published
02/19/2023 1:27 PM
VeriFinder Display Searching Background Source No Alarm
រូប​ភាព
Published
05/15/2020 2:41 PM
VeriFinder Display Gamma Alarm Acknowledge
រូប​ភាព
Published
05/15/2020 2:37 PM
Mark_Source_Location_Trefoil
រូប​ភាព
Published
02/19/2023 10:54 AM
VeriFinder Display Menu for Identification Start
រូប​ភាព
Published
05/15/2020 2:35 PM
VeriFinder Display Timer Progress for Identification
រូប​ភាព
Published
05/15/2020 2:33 PM
VeriFinder Acknowledge Alarm Choice
រូប​ភាព
Published
10/29/2020 4:24 PM
VeriFinder Display Identification Am-241
រូប​ភាព
Published
05/15/2020 2:29 PM
VeriFinder Display Select Action to Finish
រូប​ភាព
Published
05/15/2020 2:26 PM
VeriFinder File Transfer USB Cable
រូប​ភាព
Published
10/29/2020 4:10 PM
VeriFinder Save to USB Menu
រូប​ភាព
Published
10/29/2020 8:20 PM
Verifinder Export Complete Message
រូប​ភាព
Published
10/29/2020 8:12 PM
verifinder_ui_finish_000450.png
រូប​ភាព
Published
11/01/2020 5:50 PM
Verifinder Connector Ports with Battery Cable Installed
រូប​ភាព
Published
05/15/2020 2:57 PM
VeriFinder Charger Battery
រូប​ភាព
Published
10/29/2020 3:57 PM

RadSeeker Operation

Last Updated: 07/15/2025 1:35 AM

The following table lists all the components that make up the document.

Title Type Status Last Updated
Smiths Detection RadSeeker CS
Device
Published
06/04/2025 3:30 PM
247 - 257 - Prepare instrument; Remark:
Procedure Step
Published
04/11/2025 9:08 PM
257 - Prepare instrument
Instruction
Published
04/11/2025 9:07 PM
786 - 219 - Verify there are no sources of radiation near instrument; Remark:7
Procedure Step
Published
04/20/2025 6:37 PM
219 - Verify there are no sources of radiation near instrument
Instruction
Published
04/12/2025 4:20 PM
7 - No Radiation symbol
Remark
Published
07/12/2021 1:34 PM
2348 - 2295 - Verify sufficient battery charge; Remark:2301
Procedure Step
Published
11/04/2020 2:35 PM
2295 - Verify sufficient battery charge
Instruction
Published
04/06/2021 4:43 PM
2301 - Open the battery cover to view the charge level indicator.
Remark
Published
07/23/2021 8:38 PM
2302 - Replace battery pack or charge instrument if fewer than two (2) bars are visi...
Remark
Published
07/27/2021 12:20 PM
2297 - IO RadSeeker 3 bar Battery
Remark
Published
10/19/2024 10:28 PM
2460 - 220 - Power on instrument; Remark:2303
Procedure Step
Published
11/04/2020 5:34 PM
2360 - Caution : Temperature must be above -15°C for instrument to start. Do not operate the ...
Annotation
Published
11/04/2020 5:27 PM
220 - Power on instrument
Instruction
Published
04/06/2025 7:00 PM
2303 - Press and hold ENTER button until display powers on (3 to 5 ...
Remark
Published
07/23/2021 8:41 PM
2298 - IO RadSeeker Button Pad Select Button Yellow Box
Remark
Published
10/21/2024 7:26 PM
2462 - 612 - Wait for instrument to complete start-up sequence; Remark:2306
Procedure Step
Published
04/13/2025 6:49 PM
612 - Wait for instrument to complete start-up sequence
Instruction
Published
04/13/2025 6:38 PM
2306 - The instrument will automatically enter Detect mode after sy...
Remark
Published
07/23/2021 8:45 PM
2463 - 319 - Perform operational test; Remark:2307
Procedure Step
Published
07/23/2021 10:00 PM
319 - Perform operational test
Instruction
Published
06/10/2021 8:31 PM
2307 - It is recommended to perform an operational test daily before use. See DET-HH...
Remark
Published
11/04/2020 5:38 PM
3495 - 3494 - Collect background measurement; Remark:
Procedure Step
Published
07/27/2021 7:21 PM
3494 - Collect background measurement
Instruction
Published
08/27/2024 5:25 PM
3532 - 3525 - Navigate to Menu; Remark:3526
Procedure Step
Published
07/29/2021 9:55 AM
3525 - Navigate to Menu
Instruction
Published
07/29/2021 6:41 AM
3526 - Press DOWN to select Menu.
Remark
Published
07/29/2021 6:42 AM
3533 - 3527 - Press ENTER to select Collect New Background; Remark:3534
Procedure Step
Published
07/29/2021 10:50 AM
3527 - Press ENTER to select Collect New Background
Instruction
Published
07/29/2021 6:52 AM
3534 - RadSeeker Menu New Background
Remark
Published
07/29/2021 10:06 AM
3535 - 2220 - Wait for measurement to complete; Remark:3528
Procedure Step
Published
04/20/2025 12:52 PM
2220 - Wait for measurement to complete
Instruction
Published
10/22/2020 11:15 AM
3528 - Progress is shown at the bottom of the screen.
Remark
Published
07/29/2021 6:54 AM
3537 - 3529 - Press ENTER to acknowledge background; Remark:3536
Procedure Step
Published
07/29/2021 10:56 AM
3529 - Press ENTER to acknowledge background
Instruction
Published
07/29/2021 7:14 AM
3536 - RadSeeker Complete Background Collection
Remark
Published
07/29/2021 10:55 AM
3538 - 3530 - Return to Detect; Remark:3531
Procedure Step
Published
07/29/2021 11:19 AM
3530 - Return to Detect
Instruction
Published
07/29/2021 7:16 AM
3531 - Scroll to Back and press ENTER.
Remark
Published
07/30/2021 2:42 PM
2464 - 365 - Locate RN material; Remark:
Procedure Step
Published
07/30/2021 2:48 PM
3539 - Note : The instrument screen will turn black after a period of inactivity; only coun...
Annotation
Published
07/30/2021 2:47 PM
365 - Locate RN material
Instruction
Published
06/10/2021 8:45 PM
2465 - 2352 - Verify Audible Dose Rate Indicator (ADI) is on; Remark:2308
Procedure Step
Published
07/23/2021 10:04 PM
2352 - Verify Audible Dose Rate Indicator (ADI) is on
Instruction
Published
07/29/2021 12:52 PM
2308 - Press the UP arrow to activate the ADI.
Remark
Published
11/04/2020 5:08 PM
7071 - 408 - Survey close to surface of item; Remark:7070
Procedure Step
Published
02/22/2023 11:22 AM
408 - Survey close to surface of item
Instruction
Published
06/10/2021 8:50 PM
7070 - Maintain a distance of approximately 5 to 10 cm from surface of item. Do not ...
Remark
Published
02/22/2023 11:21 AM
2466 - 2215 - Survey slowly over entire item; Remark:2315
Procedure Step
Published
07/23/2021 9:08 PM
2215 - Survey slowly over entire item
Instruction
Published
04/06/2021 5:07 PM
2315 - Move instrument approximately 20 cm per second. Thoroughly survey all accessi...
Remark
Published
11/04/2020 5:09 PM
2309 - IO RadSeeker Raster Scan Box
Remark
Published
11/04/2020 7:37 AM
2467 - 2353 - Observe display and listen for audible alarms or vibration; Remark:2310
Procedure Step
Published
07/23/2021 9:14 PM
2353 - Observe display and listen for audible alarms or vibration
Instruction
Published
11/04/2020 4:51 PM
2310 - Gamma Dose Rate (µSv/hr) values will increase. Gamma coun...
Remark
Published
11/04/2020 7:38 AM
2311 - IO RadSeeker Vibrate Sound Icons
Remark
Published
11/04/2020 5:11 PM
2468 - 2357 - Acknowledge alarms; Remark:2312
Procedure Step
Published
05/02/2022 10:57 AM
2357 - Acknowledge alarms
Instruction
Published
07/23/2021 9:29 PM
2312 - Press ENTER to acknowledge any alarms.
Remark
Published
07/23/2021 10:45 PM
405 - 368 - Mark point(s) of interest; Remark:4277
Procedure Step
Published
04/20/2025 5:44 PM
368 - Mark point(s) of interest
Instruction
Published
06/11/2021 9:23 AM
4277 - Place a marker (tape, pencil, etc.) on points exhibiting elevated radiation. ...
Remark
Published
04/20/2025 5:37 PM
857 - 856 - Identify Isotopes; Remark:
Procedure Step
Published
11/04/2020 6:06 PM
856 - Identify Isotopes
Instruction
Published
07/23/2021 9:20 PM
2489 - 2218 - Place instrument close to measurement location; Remark:2325
Procedure Step
Published
11/04/2020 5:45 PM
2218 - Place instrument close to measurement location
Instruction
Published
04/06/2021 5:15 PM
2325 - The instrument should be as close as possible without making contact.
Remark
Published
07/23/2021 10:42 PM
2323 - IO RadSeeker Trefoil Box Identify
Remark
Published
11/04/2020 7:40 AM
2490 - 859 - Start identification measurement; Remark:2322
Procedure Step
Published
07/23/2021 10:18 PM
859 - Start identification measurement
Instruction
Published
10/26/2020 7:00 PM
2322 - Press ENTER under Start ID.
Remark
Published
07/23/2021 10:39 PM
2491 - 2220 - Wait for measurement to complete; Remark:2321
Procedure Step
Published
04/20/2025 12:55 PM
2321 - IO RadSeeker Collecting Spectrum Wait
Remark
Published
10/21/2024 8:36 PM
2492 - 2357 - Acknowledge alarms; Remark:2326
Procedure Step
Published
11/04/2020 5:49 PM
2326 - Press ENTER to acknowledge innocent or threat alarms.
Remark
Published
07/23/2021 9:35 PM
2320 - IO RadSeeker Alarm Acknowledge Threat
Remark
Published
10/21/2024 8:40 PM
2493 - 2221 - Observe identification results; Remark:2319
Procedure Step
Published
11/04/2020 5:50 PM
2221 - Observe identification results
Instruction
Published
04/06/2021 5:20 PM
2319 - IO RadSeeker Identify Isotope Co60
Remark
Published
10/21/2024 8:42 PM
2485 - 3545 - Document event number for later reference; Remark:3487
Procedure Step
Published
08/02/2021 10:20 AM
2362 - Note : The instrument automatically saves identification results.
Annotation
Published
07/30/2021 3:01 PM
3545 - Document event number for later reference
Instruction
Published
08/02/2021 10:17 AM
3487 - IO RadSeeker Event Number
Remark
Published
07/27/2021 4:33 PM
2494 - 2358 - Add identification time (if needed); Remark:2327
Procedure Step
Published
07/30/2021 3:02 PM
2363 - Note : Additional identification time may be needed due to a weak radioactive source...
Annotation
Published
11/04/2020 5:30 PM
2358 - Add identification time (if needed)
Instruction
Published
07/30/2021 3:04 PM
2327 - Press the UP arrow to add time.
Remark
Published
07/30/2021 3:02 PM
2318 - IO RadSeeker Add Time Button
Remark
Published
11/04/2020 1:55 PM
2328 - Press DOWN to choose additional time needed. Press E...
Remark
Published
07/30/2021 3:03 PM
2495 - 2359 - Return to Detect mode; Remark:2317
Procedure Step
Published
11/04/2020 5:52 PM
2359 - Return to Detect mode
Instruction
Published
07/30/2021 3:06 PM
2317 - Press ENTER under Detect.
Remark
Published
07/23/2021 9:40 PM
399 - 375 - Document results; Remark:394
Procedure Step
Published
06/11/2021 9:46 AM
375 - Document results
Instruction
Published
06/11/2021 9:37 AM
394 - Document results per Standard Operating Procedures.
Remark
Published
06/11/2021 9:36 AM
2497 - 313 - Power off instrument; Remark:2330
Procedure Step
Published
11/04/2020 5:53 PM
313 - Power off instrument
Instruction
Published
07/23/2021 2:41 PM
2330 - Press ENTER until the screen displays Shutting down
Remark
Published
07/23/2021 9:42 PM
2316 - IO RadSeeker Shutting Down
Remark
Published
11/04/2020 4:58 PM
3544 - 3541 - Charge batteries; Remark:3542
Procedure Step
Published
07/30/2021 3:29 PM
3540 - Note : Always charge batteries when not in use.
Annotation
Published
07/30/2021 3:22 PM
3541 - Charge batteries
Instruction
Published
07/30/2021 3:22 PM
3542 - Two (2) batteries are supplied with the RadSeeker. Remove charger plug. Align...
Remark
Published
07/30/2021 3:28 PM
3543 - Batteries can also be charged using the external charger.
Remark
Published
07/30/2021 3:28 PM
Operator Procedure
Document Type
Published
03/02/2020 3:31 PM
Caution
Annotation Type
Published
03/02/2020 3:24 PM
Note
Annotation Type
Published
03/02/2020 3:25 PM
No Radiation Symbol
រូប​ភាព
Published
08/13/2024 2:56 PM
radseeker_di_battopen_2arrow_00659.jpg
រូប​ភាព
Published
10/20/2023 9:31 AM
radseeker_di_battbar_000477.jpg
រូប​ភាព
Published
10/18/2023 4:32 PM
radseeker_di_selectmiddle_00473.jpg
រូប​ភាព
Published
10/20/2023 9:35 AM
radseeker_ui_modedetect_217cps_00467.jpg
រូប​ភាព
Published
10/20/2023 10:15 AM
radseeker_ui_menuselectright_00667.jpg
រូប​ភាព
Published
10/20/2023 10:12 AM
radseeker_ui_bkgdnew_00664.jpg
រូប​ភាព
Published
10/20/2023 9:44 AM
radseeker_ui_bkgdprogress_00665.jpg
រូប​ភាព
Published
10/20/2023 9:44 AM
radseeker_ui_bkgdcomplete_00663.jpg
រូប​ភាព
Published
10/20/2023 9:43 AM
radseeker_menuback_00662.jpg
រូប​ភាព
Published
10/20/2023 9:38 AM
radseeker_ui_adiselect_00471.jpg
រូប​ភាព
Published
10/20/2023 9:42 AM
radseeker_di_raster_000474.jpg
រូប​ភាព
Published
10/18/2023 4:43 PM
radseeker_ui_increasgr_11164cps_00463.jpg
រូប​ភាព
Published
10/20/2023 10:07 AM
radseeker_di_audio_00472.jpg
រូប​ភាព
Published
10/20/2023 8:54 AM
radseeker_ui_neutronalarmack_252cps_00469.jpg
រូប​ភាព
Published
10/20/2023 10:17 AM
Mark_Source_Location_Trefoil
រូប​ភាព
Published
02/19/2023 10:54 AM
radseeker_di_pointident_000475.jpg
រូប​ភាព
Published
10/18/2023 4:40 PM
radseeker_ui_startid_11164cps_00458.jpg
រូប​ភាព
Published
10/20/2023 10:21 AM
radseeker_ui_collectspec_00468.jpg
រូប​ភាព
Published
10/20/2023 9:46 AM
radseeker_ui_threatack_1025cps_00457.jpg
រូប​ភាព
Published
10/20/2023 10:22 AM
radseeker_ui_idco60_902cps_00465.jpg
រូប​ភាព
Published
10/20/2023 10:06 AM
radseeker_ui_eventid_00666.jpg
រូប​ភាព
Published
10/20/2023 9:47 AM
radseeker_idco60addtime_00464.jpg
រូប​ភាព
Published
10/20/2023 9:35 AM
radseeker_idselect30sec_00461.jpg
រូប​ភាព
Published
10/20/2023 9:37 AM
radseeker_ui_menuselectmiddledetect_00466.jpg
រូប​ភាព
Published
10/20/2023 10:11 AM
radseeker_ui_shut_00460.jpg
រូប​ភាព
Published
10/20/2023 10:19 AM
radseeker_di_chargepluggerout_00660.jpg
រូប​ភាព
Published
10/20/2023 9:31 AM
radseeker_di_chargerconnect_00661.jpg
រូប​ភាព
Published
10/20/2023 9:32 AM
radseeker_di_battchargerstand_00658.jpg
រូប​ភាព
Published
10/20/2023 9:30 AM